technical publication ipc 2002 A Cosham et alFull description
With Rajiv Ranjan APPAREL STANDARDS SPECIFICATION AND QUALITY CONTROL DEFECT ANALYSIS OF 4 GARMENTS NOVEMBER 10, 2010 SHIRT DEFEC T NO. DEFECT NAME LOCATION CAUSE REMEDY DEPARTME NT PICTURE 1. ...Full description
klnvkjsdnv
bone defectFull description
skull defect
askep skull defectDeskripsi lengkap
paper on PL Defect Lessons_learntFull description
Atrial Septal Defect (ASD) adalah terdapatnya hubungan antara atrium kanan dengan atrium kiri yang tidak ditutup oleh katup. ( Markum, 1991). ASD adalah suatu lubang pada dinding (septum) ya…Deskripsi lengkap
bone defectDeskripsi lengkap
lp skull defectFull description
Pipeline defect assessmentFull description
Ventrikel Septal DefectDeskripsi lengkap
LP skull defectDeskripsi lengkap
skull defectDeskripsi lengkap
dddddd
Pipeline Defect Assessment Manual
Deskripsi lengkap
When inspecting garments for cleanliness and fabric flaws, the location of the defect and its effect on the appearance and performance of a garment must be taken into consideration. Size and severi...Full description
1.1 SuporUp Analysis 1.1.1 Step 1: Open the File
First, find the icon
in the PC and double click to open it. Find File in the menu and click it to
open Φ57mm data. Then move the mouse to B image area and right click to open the display menu. Select CD Selection and Weld-
Fig. 1- 1 SuporUp Software-
Page 1 of 4
Measure “flaw depth
Measure “flaw height”
and horizontal
on B image.
distance” on A image.
Measure “flaw length” on C image.
Fig. 1-2 Recommended Method for Flaw Measurement 1.1.2.1 Step 1): Flaw Length First, move the cursor mouse to C image area and right click to display the menu. Select Bond Line and Center Line covered. See Fig. 1- 3.
Fig. 1- 3 Turn on Bone Line Then right click on C image to enable Measure Line. Select MeasureLine 1 and move it to the start position of flaw. Select MeasureLine 2 and move it to the end position of flaw (the 6dB method is generally recommended for selecting the start and end positions). See Fig. 1- 4.
Fig. 1- 4 Phased Array C Image Display
Click the icon
(Flaw Length) in the tool bar. The measurement will be displayed in Page 2 of 4
MeasureResult. See Fig. 1- 5.
Fig. 1- 5 Flaw Length 1.1.2.2 Step 2): Flaw Height First, move MeasureLine 1 or 2 on C image to find the maximum energy of the flaw, and acquire a B image at the same time. Then turn on MeasureLine on B image. Select MeasureLine 1 and move it to the start position of the flaw. Select MeasureLine 2 and move it to the end position of flaw (the 6dB method is generally recommended for selecting the start and end positions). See Fig. 1- 6.
Fig. 1- 6 Energy Maximum Place of Flaw Click the icon
(Flaw Height) in the tool bar. The measurement will be displayed in
MeasureResult. See Fig. 1- 7.
Fig. 1- 7 Flaw Height 1.1.2.3 Step 3): Flaw Depth Adjust “A scan line” to find out the highest echo of the flaw based on the above steps. See Fig. 18.
Page 3 of 4
A Scan line Fig. 1- 8 Flaw Depth Measurement Click the icon
(Flaw Depth) in the tool bar. The measurement will be displayed in