Método de Prueba estándar para Viscosidad cinemática de Líquidos Transparentes y Opacos (Y Cálculo de Viscosidad Dinámica)1
astmDescrição completa
viscocidadDescripción completa
Descripción completa
ASTM D 1587
ASTM D 1587Deskripsi lengkap
Descripción: ASTM D 1587
Full description
ASTM D 1586 en inglesDeskripsi lengkap
ASTM standard
Full description
Descripción: Norma astm 2938
Norma ASTM D 12 17
Norma para determinar el contenido de agua y sedimento por centrifugaDescripción completa
ASTM D 3363-05 norma americana
metodo para determinar el limite de contraccion mediante metodo de la parafinaFull description
Descripción completa
Descripción completa
ASTM method
Spectro Inc. - ASTM D445
Page 1 of 1 Home Ho me | Fi Find nd Re Repr pres esen enta tati tive ves s | Co Cont ntac actt Us | Si Site te Ma Map p | Pa Part rtne nerr Lo Logi gin n | Cu Cust stom omer er Lo Logi gin n
Ourr Re Ou Repr pres esen enta tatitive vess
ASTM Methods ASTM 6595 (Wear Metals in Used Oils) ASTM 6728 (Alkali Metals in Fuel) ASTM D445 (Viscosity) ASTM D7279 (Viscosity) ASTM D7371 (FAME) ASTM E2412 (Used oil FT-IR)
9788-4 97 -486 86--01 0123 23
ASTM D445 This is an ASTM International Standard Test Method for the analysis of viscosity in used and new lubricants. 300 310 The SpectroVISC Q and SpectroVISC Q meet and exceed the requirements of this specification. Copies of the complete method are available from the ASTM web site at http://www.astm.org.. The full title and partial scope of the method http://www.astm.org is listed below:
Free Consultancy Ask the experts about your in-service oil analysis problem!
ASTM D445 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) ■ ■
Chemical Properties Physical Properties
■
■
1. Scope 1.1 This test method specifies a procedure for the (Click Image to Enlarge) determination of the kinematic viscosity, of liquid petroleum products, both transparent and opaque, by measuring the time for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer. The dynamic viscosity can be obtained by multiplying the kinematic viscosity, by the density, of the liquid.
Contact Us Please send us your questions.
1.2 The result obtained from this test method is dependent upon the behavior of the sample and is intended for application to liquids for which primarily the shear s tress and shear rates are proportional (Newtonian flow behavior). If, however, the viscosity varies significantly with the rate of shear, different results may be obtained from viscometers of different capillary diameters. The procedure and precision values for residual fuel oils, which under some conditions exhibit non-Newtonian behavior, have been included. 1.3 The range of kinematic viscosities covered by this test method is from 0.2 to 300 000 mm2/s (see Table A1.1) at all temperatures (see 6.3 and 6.4). The precision has only been determined for those materials, kinematic viscosity ranges and temperatures as shown in the footnotes to the precision section.