Jordan Orange 2G&3G Swap and LTE Project RF ANT Swap Checklist Site ID:
Swap date:
Swap start time:
/
/
Swap end time:
/
/
Subcontractor(signature): Name______________ Identify ID________________ HW SE (signature): Name_______________ employee ID______________ RF Swap Preparation: 1
Yes/No
Subcontractor check that tools prepared completely (Compass □,Site Master □,Mechanical Tilt test tool □, Multimeter□,homing/another network SIM card□,cell phone 2 □)
Yes □, No □ Yes □, No □
2 Subcontractor should arrive site 2 hours in advance before swap 3
Subcontractor check Mechanical tilt&Electrical tilt &Azimuth on E//site, record it and double confirm with OMC engineer by following 3G existing antenna
Yes □, No □
4 Subcontractor power on MW and call OMC to confirm transmisson is ok
Yes □, No □
5 Subcontractor call OMC to confirm the RF Antenna SWAP start time
Yes □, No □ Yes/No
Duration RF Swap(down time): 6 Subcontractor check Antenna Azimuth is the same with existing 3G antenna data
Yes □, No □
7 Subcontractor set Mechanical tilt and make sure it is the same with existing 3G antenna data
Yes □, No □
8
Remark
Subcontractor inform OMC to set Electrical tilt and make sure it is the same with existing 3G antenna data
Remark
Yes □, No □ Yes □, No □
9 Subcontractor make sure Jumper between feeder&RRU and antenna are fixed After RF Swap:
Yes/No Sector 1(2G) Yes □, No □ Sector 2(2G) Yes □, No □
10 Subcontractor make Call/Web browse/SMS test and record test result.
Remark
Sector 1(3G) Yes □, No □2(3G) Sector
Sector 1(4G) Yes □, No □
Yes □, No □
Sector 2(4G) Yes □, No □
Sector 3(2G) Yes □, No □
Sector 3(3G) Yes □, No □
Sector 3(4G) Yes □, No □
Sector 4(2G) Yes □, No □
Sector 4(3G) Yes □, No □
Sector 4(4G) Yes □, No □
Sector 5(2G) Yes □, No □
Sector 5(3G) Yes □, No □
Sector 5(4G) Yes □, No □
Sector 6(2G) Yes □, No □
Sector 6(3G) Yes □, No □
Sector 6(4G) Yes □, No □
11 Subcontractor resolve alarms with OMC engineer
Yes □, No □
12 Subcontractor inform OMC to check VSWR(<=1.3) after SWAP
Yes □, No □
13 Subcontractor check site working status is nomal or not with OMC engineer(MW and WL)
Yes □, No □
14 Subcontractor Call OMC to inform customer that swap is compeleted
Yes □, No □
15 Subcontractor must finish site clean and take picture before leave
Yes □, No □
Parameter Before swap: Site ID
Sector
Exsiting 3G Azimuth (Angle shift from zero North Direction)
Exsiting 3G Mechanical Tilt
Exsiting Electrical Tilt 2G
AISG Connection
3G
Yes □, No □ Yes □, No □ Yes □, No □ Yes □, No □ Yes □, No □ Yes □, No □ Parameter After swap: Site ID
Sector
New Azimuth (Angle shift New Mechanical from zero North Direction) Tilt
2G
New Electrical Tilt 3G
4G
AISG Connection Yes □, No □ Yes □, No □ Yes □, No □ Yes □, No □ Yes □, No □ Yes □, No □