Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
1
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
1
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Nokia Siemens Networks Academy Legal notice Intellectual Property Rights All copyrights and intellectual property rights for Nokia Siemens Networks training documentation, product documentation and slide presentation material, all of which are forthwith known as Nokia Siemens Networks training material, are the exclusive property of Nokia Siemens Networks. Nokia Siemens Networks owns the rights to copying, modification, translation, adaptation or derivatives including any improvements or developments. Nokia Siemens Networks has the sole right to copy, distribute, amend, modify, develop, license, sublicense, sell, transfer and assign the Nokia Siemens Networks training material. Individuals can use the Nokia Siemens Networks training material for their own personal self-development only, those same individuals cannot subsequently pass on that same Intellectual Property to others without the prior written agreement of Nokia Siemens Networks. The Nokia Siemens Networks training material cannot be used outside of an agreed Nokia Siemens Networks training session for development of groups without the prior written agreement of Nokia Siemens Networks.
2
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
2
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Objectives After completing this learning element, the participant should be able to: Theory: • List supported licensed features • Recognize different license types. • Know how to activate the licence features • Software compatibility of Flexi Multiradio BTS GSM/EDGE • Match the BTS features according to the BSC and NetAct software revisions
3
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
3
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Table of Content
Introduction Flexi Multiradio BTS GSM/EDGE SW Compatibility Features Supported for Flexi Multiradio BTS GSM/EDGE Licence Activation
4
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
4
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Table of Content
Introduction Flexi Multiradio BTS GSM/EDGE SW Compatibility Features Supported for Flexi Multiradio BTS GSM/EDGE Licence Activation
5
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
5
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility Introduction
6
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
6
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Introduction Licence key-based Feature Management • Licence key-based feature management means that the use of certain features is controlled by licences. Once a valid licence has been installed, it is possible to activate and deactivate the application software covered by the licence. • One licence key file may, in practice, cover one or more features. • Licence management is handled in the BSC as in previous generation BTSs • Licence types : Capacity licence
On/off licence
• defines the allowed capacity that the feature can use or provide. • Capacity licences permit the capacity to be increased stepwise by installing more capacity licences i.e. capacity increments for the same feature(s). • The capacities of these licences are then summed up to get the total capacity that the feature is allowed to use or provide. 7
© Nokia Siemens Networks
• non-capacity feature licence • allows the feature to run without capacity limitations Both licence types above can be timelimited. This means that the licence covering the feature has a pre-defined expiration date, which is stated in the licence file.
RA22762EN01GLA0
-The SW license managament feature is an improvement over the CX(M) UltraSite and MetroSite BTS product families. -No SW license or keys needed for production testing -LAPD links are created and the base stations are created to the BSC's radio network database: In terms of BSC, a base station consists of BCF, BTSs, TRXs, and handover and power control parameters. -The BTS SW receives BCF, OMU or TRX startup BTS_CONF_DATA messages from BSC. E.g. Abis signal mapping is sent to BTS in BTS_CONF_DATA always when BCF, BTS or TRX unlock is done or BCF reset is run.
RA22762EN01GLA0
7
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Introduction Licence Management by NetAct (1/2) Licence Management by NetAct (1/2) • Licence order support • Licence file importing • Licence file distribution • Feature activation and deactivation License Distribution NetAct New License file
BTS
Licence Delivery Sytem Distributing to NEs
BSC
WBTS RNC
8
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
8
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Introduction Licence Management by NetAct (2/2) Licence Management by NetAct (2/2) • Licence file deletion • Licence synchronization • Licence reporting • Licence expiration checking License synchronization NetAct
Archive Directory for all Licence Files
BTS Upload from NEs
BSC
WBTS RNC
9
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
9
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Table of Content
Introduction Flexi Multiradio BTS GSM/EDGE SW Compatibility Features Supported for Flexi Multiradio BTS GSM/EDGE Licence Activation
10
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
10
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility Flexi Multiradio BTS GSM/EDGE SW Compatibility
11
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
11
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Flexi Multiradio BTS GSM/EDGE SW Compatibility Software Release naming RG10 (BSS14): EP3 (Flexi EDGE only) • Current main release of Flexi EDGE SW (EP3 MP4.0 to be released next) EX3.1 (Flexi MultiRadio EDGE only) compatible with BSC SW S14 EP5.1 • EX3.1 MP1.0 will contain some features delayed from EX3.1 RG20 (BSC SW: S15): EX4 (Flexi EDGE only) • For Flexi EDGE only, main new features: OSC + Packet Abis • Part of EX3.1 code also included but not compatible with Flexi MultiRadio EDGE. RG25 (BSC SW: S15 EPx.0): EX4.1 (Flexi MultiRadio EDGE and Flexi Edge) • Brings the new EX4 features also support for Flexi MultiRadio EDGE Note: As before, it is always recommended to use the latest compatible BTS SW release to gain the benefits of BTS SW corrections, even if it belongs to newer RG release. • For example EP3 MP3.0 (part of RG10/BSS14) can also be used with S13 (part of BSS13).
12
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
12
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Flexi Multiradio BTS GSM/EDGE SW Compatibility Compatibility with BSC, NetAct, LMU, FIFA, and FlexiHub Manager SW Compatibility between Flexi Multiradio GSM/EDGE BTS, BSC, NetAct, LMU, FIFA, and FlexiHub Manager SW
13
© Nokia Siemens Networks
RA22762EN01GLA0
The table below shows the compatibility between the following software: • Flexi Multiradio Base Station Software (BTS SW) • Base Station Controller Software (BSC SW) • NetAct Software (NetAct SW) • Location Measurement Unit Software (LMU SW) • Flexi Transport Interface Flexbus Sub-module (FIFA SW)
RA22762EN01GLA0
13
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Flexi Multiradio BTS GSM/EDGE SW Compatibility Compatibility with BTS Manager and functionality support To ensure compatibility in functionality, it is recommended that the BTS Manager and BTS SW are both from the same BTS release or CD of that release
14
© Nokia Siemens Networks
RA22762EN01GLA0
To ensure compatibility in functionality, it is recommended that the BTS Manager and BTS SW are both from the same BTS release or CD of that release.
RA22762EN01GLA0
14
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Flexi Multiradio BTS GSM/EDGE SW Compatibility Compatibility with BSC and Surpass hiD 66xx Far-end PW device SW Compatibility between BTS, BSC and Surpass hiD 66xx Far-end PW device SW
The SURPASS hiD 66xx product family consists of three products, the 6630, the 6650 and the 6670 each supporting a different number of exchangeable line interface cards.
15
© Nokia Siemens Networks
RA22762EN01GLA0
The table below shows the compatibility between the following software: • Flexi Multiradio Base Station Software (BTS SW) • Base Station Controller Software (BSC SW) • Nokia Siemens Networks SURPASS hiD 66xx product family (hiD 66xx SW) • A-2200 device
RA22762EN01GLA0
15
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Table of Content
Introduction Flexi Multiradio BTS GSM/EDGE SW Compatibility Features Supported for Flexi Multiradio BTS GSM/EDGE Licence Activation
16
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
16
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility Features Supported for Flexi Multiradio BTS GSM/EDGE
17
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
17
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Features supported by Flexi Multiradio BTS GSM/EDGE - overview • Most of the functionality of Flexi Multiradio BTS GSM/EDGE in EX3.1 are the same as for Flexi EDGE BTS at RG10 level, for detail please see Feature Description document on EX3.1 Pre1 release binder. feature_description s_multiradio
• Feature licence related to TRX hardware activation of Flexi Multiradio BTS GSM/EDGE as follow:
• Note : The licence is different from TRX hardware activation of Flexi EDGE BTS
18
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
18
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Features supported by Flexi Multiradio BTS GSM/EDGE Features Delayed in Flexi Multiradio BTS GSM/EDGE EX3.1 Prerelease 1 • Following basic functionalities are excluded from the EX3.1 SW Pre-release 1 (30-Jun-2010) : • RFM Shared mode with WCDMA BTS (concurrent mode) • RFM Chaining • 4-way diversity • IDD • Hot inserted RFM Module • PWE support (FIQA/FIYA in PDH mode only) • DFCA • LMU sync (needed for DFCA) • Length of optical cables limit to only these options (2m, 50m,100m,150m,200m) • RFM block/unblock (needed mainly for sharing) • Antenna Hopping • Highlight support for RFM 19
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
19
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Features supported by Flexi Multiradio BTS GSM/EDGE – TRX capacity management • Flexi Multiradio BTS GSM/EDGE EX3.1 Software license management feature introduces BTS TRX capacity management based on the operator needs. This feature enables flexible usage of the base station in the network based on the capacity requirement.
• Each BSC has a pool of TRXs that can be allocated to its BTSs. If the required TRX cabling is already done in Flexi EDGE BTS, it is possible to take an extra (unused) TRX into service without a site visit.
• The usage of Flexi EDGE TRX software is controlled by a Flexi Multiradio TRX HW Activation Licence. The licence sets a limit for unlocked Flexi Multiradio TRX count under a Flexi EDGE BTS. Operator cannot unlock or modify Flexi EDGE BTS without the licence.
• Each FXxA module (RF Module) provides max 18 GSM/EDGE carriers. Each TRX within FXxA can be separately activated with the SW licence key -> one carrier increments possible. Application software in Configurator Tool Flexi Multiradio TRX HW Activation
20
© Nokia Siemens Networks
BSS ID number BSS21403
Feature name in Product Documentation (NED) Flexi Multiradio TRX HW Activation
Licence key type Capacity (TRX count)
Feature code
Action when licence key expires
1379
Usage is restricted with the next BCF/BTS/TRX unlock.
RA22762EN01GLA0
RA22762EN01GLA0
20
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Features supported by Flexi Multiradio BTS GSM/EDGE – Licensed transmission features • Licensed Flexi Multiradio BTS integrated transmission features will be supported in EX3.1 and be managed in the BSC, but the configuration must be done locally at the BTS site. • If the feature state is ON in BSC, user is able to enable transmission features usage in BCF creation and modification by setting values of the new BCF parameters. • Further functionality can be easily added later on by additional software licence. The protection of these functionalities will be integrated with the next software releases. List of Feature related to Transmission for Flexi Multiradio BTS GSM/EDGE Application software in Configurator Tool
21
BSS ID number
Feature name in Product Documentation (NED)
Licence key type
Feature code
Action when licence key Expires
2nd FlexBusfor FlexiEDGE BTS
L55341.05
Additional Flexbus interface
On/Off
651
Licence does not expire.
2G Flexi Abis over IP/Ethernet
BSS30305
2G Flexi Abis over IP/Ethernet
Capacity (BTS count)
1015
Feature usage is denied.
2G Flexi AbisTRS Grooming
BSS21129
2G Flexi Abis TRS Grooming
Capacity (BTS count)
907
Feature usage is denied.
2G Flexi Additional 2 E1, T1
BSS30285
2G Flexi Additional 2 E1, T1
Capacity (additional two E1/T1 interfaces)
909
Feature usage is denied.
BSS30280
2G Flexi TRS Loop
Capacity (BTS count)
908
Feature usage is denied.
2G Flexi TRS Loop Protection © Nokia Siemens Networks
RA22762EN01GLA0 Protection
Pseudo-wire Emulation: New transmission technology called "pseudowire emulation“, which is basically about emulation of circuit switched signals like E1 or T1 via a packet switched network/ethernet. Loop protection: protection method where traffic is routed via two routes around a ring FIFA: FIFA has 2 Flexbus interfaces. Flexbus 1 can be used without any licence and Flexbus 2 usage requires a separate licence. To activate Flexbus 2 interface an Additional Flexbus (FB) interface licence must be ordered and installed for FIFA. The file is delivered through software delivery channels and can easily be installed either locally or remotely over the Q1 management channel using FlexiHub Manager. Licence is implemented using secure plain text files generated and authorised by Nokia Siemens Networks. If the licence file gets lost or becomes corrupted, the valid licensed user can get a replacement from Nokia Siemens Networks without paying for the feature twice. The licence is bound to the unit's serial number and cannot be used in another unit. If FIFA hardware is swapped by Nokia Siemens Networks in a hardware failure case, a new licence file is generated. Additional Flexbus (FB) interface licence for FIFA is permanent and, once installed, will not expire. Note that FIFA includes an introductory time-limited trial licence (60 days) for the Flexbus 2 interface. Once the non-time limited licence has been purchased and downloaded to the unit, the licensed feature can be activated or deactivated as often as needed.
RA22762EN01GLA0
21
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Table of Content
Introduction Flexi Multiradio BTS GSM/EDGE SW Compatibility Features Supported for Flexi Multiradio BTS GSM/EDGE Licence Activation
22
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
22
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility Licence Activation
23
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
23
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Licence Activation Overview • A network operator who wants to acquire a licensed feature buys the licence, installs it in the BSC can then activate the feature. One licence file may, in practice, cover one or more features.
• BSC controls that used capacities do not exceed the licenced capacities. Separate feature code for each feature is used.
• User can enable/disable each feature online separately for every BCF via MML/FBPP/Q3. BSC check if the feature state is on and feature has enough capacity in BCF creation and modification when the user tries to enable the feature.
• Configured capacity values for a BCF are stored into Radio Network Database in BSC. When user enables or disables the feature or changes the feature capacity, BSC updates the new values to BTS.
24
© Nokia Siemens Networks
RA22762EN01GLA0
-Q3 is the interface between OMC and network element -FBPP: file based plan provisioning
RA22762EN01GLA0
24
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Licence Activation Licence control in BSC • The licence is a long term licence and it sets a limit for unlocked Flexi Multiradio BTS GSM/EDGE TRX count.
• Operator cannot unlock or modify Flexi EDGE BTS without the licence. • If the Flexi EDGE TRX licence does not exist or feature state is OFF, then Flexi EDGEspecific options are not shown to the user in MML commands. – When the licence has expired, operator cannot unlock TRXs
• If the user has had the licence in CONF or ON state and created Flexi EDGE BTS, then Flexi EDGE-related parameters are shown to user even if the licence state is OFF.
• BTS site type name used in MML commands is Flexi Multiradio BTS GSM/EDGE. • BSC checks that the licence is valid and that operator cannot have more Flexi EDGE TRXs in use than the licence allows.
• Operator can also check the amount of Flexi EDGE TRXs that are in use. • The current capacity level usage is requested with service fmn_capacity_usage_inquiry_as from BSC software that has registered itself as capacity manager (PUBDAT).
25
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
25
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Licence Activation Installing and activating licences
• Note: Do not change a bit in the licence file or it will not work! • See the instructions in the Licence Management in BSC and W7 - Licence and Feature Handling documents :
Licence Management in BSC
26
© Nokia Siemens Networks
W7 - Licence and Feature Handling
RA22762EN01GLA0
RA22762EN01GLA0
26
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Licence Activation Example of interrogation Licence key-based features in BSC W7I:FEA,FULL:FSTATE=ON,; FlexiBSC FlexiBSCTB 244142 2010-08-30 19:37:22 FEATURE INFORMATION: …………… --------------------------------------------FEATURE CODE:..............1379 FEATURE NAME:..............Flexi Multiradio TRX HW Activation FEATURE STATE:.............ON FEATURE CAPACITY:..........100 --------------------------------------------FEATURE CODE:..............907 FEATURE NAME:..............FlexiEDGE Abis TRS Grooming FEATURE STATE:.............ON FEATURE CAPACITY:..........100 ---------------------------------------------FEATURE CODE:..............908 FEATURE NAME:..............FlexiEDGE TRS Loop Protection FEATURE STATE:.............ON FEATURE CAPACITY:..........100 ---------------------------------------------FEATURE CODE:..............909 FEATURE NAME:..............FlexiEDGE Additional 2 E1,T1 IF FEATURE STATE:.............ON FEATURE CAPACITY:..........100 ……….
27
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
27
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
Licence Activation Example of activation Licence key-based feature in BSC
• Before you start, make sure the licence covering the feature has been installed into BSC. • When installing the licence, the initial state of the feature should be set to 'CONF • Example: W7M:FEA=1379:ON:; FlexiBSC
FlexiBSCTB
244142
2010-08-30
19:49:31
CHANGING STATE OF FEATURES: FEATURE 1379
CHANGED TO ON
COMMAND EXECUTED
28
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
28
Flexi Multiradio BTS GSM/EDGE Licensed Features & SW Compatibility
29
© Nokia Siemens Networks
RA22762EN01GLA0
RA22762EN01GLA0
29