471449A.505 Nokia Flexi WCDMA Base Station, Rel. Flexi WBTS4.0, Product Documentation, v.2
Flexi WCDMA BTS System Module Description
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
1 (44)
Flexi WCDMA BTS System Module Description
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given “as is” and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document. Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OPPORTUNITY OR DATA, DATA, THAT THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright © Nokia Siemens Networks 2008. All rights reserved.
2 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
Flexi WCDMA BTS System Module Description
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given “as is” and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document. Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OPPORTUNITY OR DATA, DATA, THAT THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright © Nokia Siemens Networks 2008. All rights reserved.
2 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
Contents
Contents Cont Conten ents ts 3 1
Sum Summary mary of chan change ges s in Flex Flexii WCDM WCDMA A BTS BTS Sys System tem Modu Module le Desc Descri ript ption ion 5
2 2.1 2.2
System Module operation and main blocks Operation 7 Functional blocks 10
3 3.1 3.1 3.2 3.2
Powe Powerr requ requir irem emen ents ts of the the Syst System em Modu Module le and and tran transm smis issi sion on subsubmodu module les s 19 Powe Powerr requ requir irem emen ents ts of the the Sys System tem Modu Module le 19 Powe Powerr requ requir irem emen ents ts of tran transm smis issi sion on subsub-mo modu dule les s 20
4
System Module dimensions and weight
5
System Module interfaces
6
System Module LED indications
7 7.1 7.1 7.2 7.3
System Module as an extension module 41 Syst System em Mod Module ule as an exte extens nsio ion n modu module le 41 FPFA interfaces 42 FPF FPFA electrical connection ions 44
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
7
21
23 23 39
3 (44)
Flexi WCDMA BTS System Module Description
4 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
Summary of changes in Flexi WCDMA BTS System Module Description
1
Summary of changes in Flexi WCDMA BTS System Module Description Changes between issues 4-0 and 5-0 Editorial changes made. Changes between issues 3-0 and 4-0 Section System Module operation and main blocks updated with information on the FTJA transmission sub-module and transmission cables. The picture of FTOA updated and a figure of the System Module type label location added. Section Power requirements of the System Module and transmission sub- modules updated with information on power requirements of transmission sub-modules and the power consumption of the FSMB and System Extension Module. Section System Module interfaces updated with information on System Module connectors. Connector pin maps and figures of connectors added. Section System Module LED indications updated the LED indications table and the LED positions figure. Section FPFA interfaces added. Section FPFA electrical connections added.
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
5 (44)
Flexi WCDMA BTS System Module Description
6 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module operation and main blocks
2 2.1
System Module operation and main blocks Operation The Flexi System Module hosts the telecom control, system operation and maintenance, baseband application, transmission, and power distribution functionality. The System Module can also act as a System Extension Module operating in a baseband extension mode. The System Module provides the following BTS external interfaces: .
BTS Site Element Manager
.
external interfaces towards the RNC (Iub)
.
three external interfaces towards RF
.
site support system interface (for example, battery back-up)
.
auxiliarity interface (customer-specific 10/100 Mbps Ethernet port with overvoltage protection)
.
auxiliarity interface 1 Gbps Ethernet for future expansions
.
external alarms and controls interface (customer-specific alarms)
.
external synchronisation input interface
.
external synchronisation output interface
The System Module has an integrated BTS clock that distributes the synchronisation clocks to other BTS modules. The System Module hardware is HSDPA and HSUPA compliant. The System Module uses nominal 48 V DC and distributes it on to RF and System Extension Modules. The System Module includes integrated fans.
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
7 (44)
Flexi WCDMA BTS System Module Description
The System Module can be used, for example, for the following software functionalities: .
BTS level O&M processing (BTSOM)
.
resource management
.
node B server
.
NBAP handler
.
user plane management
See the following figure for an exploded view of the System Module.
8 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module operation and main blocks
DN70153208
Figure 1.
DN7084495 Issue 5-0 en 21/01/2008
Exploded view of the System Module
# Nokia Siemens Networks
9 (44)
Flexi WCDMA BTS System Module Description
Type Label
DN70351805
Figure 2.
2.2
Type label location of the System Module
Functional blocks See the following figure for the functional blocks of the System Module.
10 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module operation and main blocks
Legend: Control Clock RP1’+RP2’ Data RP3’ Data
Ext IF
Fan
Fan
Ext IF block
Module heater
Temp sensors 1-8
Control block and
Timing block
TRS IF
BB processing & RP3 transcoding block
Transmission sub-module (FTxx)
BB processing & RP3 transcoding block
BB processing & RP3 transcoding block
-48 V DC RF IF
Multiplexing&Summing and RF Ethernet switching
IF block
Power
Distribution -48 V DC, block 48RTN
BB Extension IF blocks
BB Ext IF
DN7082531
Figure 3.
DN7084495 Issue 5-0 en 21/01/2008
Functional blocks of the System Module
# Nokia Siemens Networks
11 (44)
Flexi WCDMA BTS System Module Description
Flexi WCDMA BTS control and multiplexing This functionality is responsible for BTS control and management, system clock generation and distribution to other modules and sub-modules. The functional distribution of this functionality is as follows: .
.
.
.
.
Control MCU and clock generation: This includes the NBAP termination, telecom and overall BTS control functionality, system O&M functionality, external site support system and other equipment control. It generates system reference clock and frequency reference for synchronising with other BTS. External interface block: This block facilitates the external interface for external equipment control. Summing and multiplexing functionality: This functional block is used for data routing between the radio modules and the baseband. RF Module interface: This logical functional block is responsible for providing output/input interface to or from a maximum of three RF Modules. Baseband extension interface: This logical functional block is responsible for providing output/input interface to or from the System Extension Module.
Flexi WCDMA BTS signal processing The Flexi Signal Processor terminates the Iub user plane and is responsible for L1 processing of the air interface. Flexi WCDMA BTS transmission sub-module (FTxx) The transmission sub-module supports the following functionalities: .
ATM over E1/T1/JT1
.
ATM over STM-1
.
ATM over Ethernet
.
Inverse Multiplexing ATM (IMA)
.
Synchronisation
.
Iub terminations .
Common NBAP and Dedicated NBAP
.
AAL2 Signaling and AAL2 User Paths
.
12 (44)
Operation and Maintenance (DCN)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module operation and main blocks
.
Iu-PS Control Plane and Iu-PS User Plane
.
Iur Control Plane and Iur User Plane
.
IP functionalities (DHCP, routing, NTP, packet filtering)
.
Transport performance counters
Different variants of the transmission sub-module in the System Module are supported in order to provide different interface types in the Flexi WCDMA BTS. Transmission sub-modules (FTxx) provide the physical Iub interface to the radio network controller (RNC). Transmission sub-module variants and their functions are listed in the following table.
Table 1.
Transmission sub-module variants and their functions
Variant
Function
FTPB
Provides eight PDH symmetrical interfaces configurable as E1, T1, or JT1.
FTEB
Provides eight PDH coaxial interfaces E1.
FTFA
Provides two Nokia FlexBus interfaces.
FTIA
Provides four PDH symmetrical interfaces configurable as E1, T1, or JT1 and two Ethernet interfaces + one Gigabit Ethernet. 1)
FTOA
Provides one optical STM-1 interface
FTJA
Provides four PDH coaxial interfaces E1 and two Ethernet interfaces + one Gigabit Ethernet.
1)
Gigabit Ethernet requires additional hardware (Small Form-factor Pluggable, SFP transceiver).
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
13 (44)
Flexi WCDMA BTS System Module Description
DN70148552
Figure 4.
Transmission sub-module FTPB
DN70148588
Figure 5.
14 (44)
Transmission sub-module FTEB
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module operation and main blocks
DN70148576
Figure 6.
Transmission sub-module FTFA
DN70148564
Figure 7.
DN7084495 Issue 5-0 en 21/01/2008
Transmission sub-module FTIA
# Nokia Siemens Networks
15 (44)
Flexi WCDMA BTS System Module Description
DN70245378
Figure 8.
Transmission sub-module FTOA
DN70348735
Figure 9.
Transmission sub-module FTJA
See the following table for listing of outdoor transmission cables used for Flexi WCDMA BTS transmission sub-module (FTxx).
16 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module operation and main blocks
Table 2.
Outdoor transmission cables
Transmission cable
Type
Resistance [ohm]
Length
FTCA
OD Cable
120 ohm
5m
120 ohm
15m
75 ohm
5m
75 ohm
15m
OD Cable
50 ohm
15m
LC SM
1310 nm
OD Cable
50 ohm
2.5m
100ohm
15m
120 ohm
30m
120 ohm
50m
75 ohm
30m
75 ohm
50m
100 ohm
30m
100 ohm
50m
RJ48C-TQ-M/0 FTCB
OD Cable RJ48C
FTCD
OD Cable SMB-F/0-BT43-F/0
FTCE
OD Cable SMB-F/0
FTCH
FTCJ
TNC-F/0-TNC M/0 FTCR
OD Cable RJ 45 CAT5E
FTCV
OD Cable RJ48C
FTCX
OD Cable RJ48C
FTCF
OD Cable SMB-F/0
FTCG
OD Cable SMB-F/0
FTCS
OD Cable RJ 45 CAT5E
FTCT
OD Cable RJ 45 CAT5E
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
17 (44)
Flexi WCDMA BTS System Module Description
18 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
Power requirements of the System Module and transmission submodules
3 3.1
Power requirements of the System Module and transmission sub-modules Power requirements of the System Module The power supply of the System Module (FSMB) is described in the table below. The same power consumption figures also apply for the System Extension Module.
Table 3.
Power consumption of the FSMB (not including transmission) and System Extension Module
Property
Value
Max.
170 W*
Typical
106 W
Min.
90 W
Nominal supply voltage
48 V DC**
Input voltage range
40.5 - 57 V DC**
*During cold start-up **Operational power consumption at room temperature. The fuse rate for the System Extension Module is 25A. For transmission sub-module power consumption figures, see section Power requirements of transmission sub-modules.
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
19 (44)
Flexi WCDMA BTS System Module Description
3.2
Power requirements of transmission sub-modules The typical power consumption of the transmission sub-modules is described in the table below.
Table 4.
Power consumption of the transmission sub-modules
Variant
Typical power consumption [W]
FTPB
22.3 W
FTEB
22.3 W
FTFA
89.7 W
FTIA
22.8 W
FTOA
22.8 W
FTJA
22.8 W
Power consumption depends on the equipment connected to the FTFA sub-module.
20 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module dimensions and weight
4
System Module dimensions and weight The table below lists the dimensions and weight of the System Module.
Table 5.
Dimensions and weight of the System Module
Property
Value
Height
133 mm / 3U (5.2 in.)
Width
447 mm (17.6 in.)
Depth without covers
422 mm (16.6 in.)
Depth with covers
560 mm (22 in.)
Weight (without transmission sub-module) max 18 kg (39.8 lbs)
Table 6.
Dimensions and weight of the transmission sub-modules.
Property
Value
Height
41 mm (1.6 in.)
Width
245 mm (9.7 in.)
Depth
308 mm (12.1 in.)
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
21 (44)
Flexi WCDMA BTS System Module Description
Table 6.
Dimensions and weight of the transmission sub-modules. (cont.)
Property
Value
Weight
max. 4 kg (8.8 lbs)
Warning The module is heavy. Take care when lifting the module.
22 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module interfaces
5
System Module interfaces The System Module is equipped with the following interfaces: .
Front panel connectors
.
DC input connector (in the centre of the module)
The System Module has 24 connectors on the module. The connectors, their types and purposes are listed in the table below. The System Module is connected to the System Extension Module with a DC cable and two optical cables.
Table 7.
System Module connectors
Connector
Type
Purpose
Power supply RF module 1
Multi-beam XL power supply connector
Power delivery to RF1. Fuse rating 20A.
Power supply RF module 2
Multi-beam XL power supply connector
Power delivery to RF2. Fuse rating 20A.
Power supply RF module 3
Multi-beam XL power supply connector
Power delivery to RF3. Fuse rating 20A. Recommended for I-HSPA use. Can be used for GPS mediator (FSEG).
Power supply System Extension Module operating in BB-ext mode
Multi-beam XL power supply connector
Power delivery to System Extension Module operating in BB-ext mode and to the main fuse for System Modules. Fuse rating 25A. Can be used for I-HSPA and GPS mediator (FSEG).
Transmission interfaces
8 x RJ-48/16 x SMB/2 x TNC/1 x duplex LC connector
Variable transmission interfaces
2 x RJ-45 connector 1x GE via SFP transceiver 10/100 Eth
RJ-45 connector
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
For local management tool
23 (44)
Flexi WCDMA BTS System Module Description
Table 7.
System Module connectors (cont.)
Connector
Type
Purpose
10/100 Eth FPMA
RJ-45 connector
Site support control over IP/ site support hard-wired alarms
10/100 Eth OVP1)
RJ-45 connector
Control and location data transfer
1000 Eth
RJ-45 connector
External transport equipment interface (for future use)
EAC
MDR36 connector
External alarms and controls
Sync out
MDR14 connector
BTS synchronization output interface
Sync in
MDR26 connector
BTS synchronization input interface (for external sources)
OPT-RF 1
Duplex LC connector
Interface for RF Module 1
OPT-RF 2
Duplex LC connector
Interface for RF Module 2
OPT-RF 3
Duplex LC connector
Interface for RF Module 3
OPT-EXT 1
Duplex LC connector
System and baseband extension interfaces
OPT-EXT 2
Duplex LC connector
System and baseband extension interfaces
DC input
TX25 screw terminals for 8 25 mm2 cable
Grounding
Screw M5
…
Power feed Grounding
1)
The 10/100 Eth OVP cable fulfils overvoltage surge protection standard GR-1089 Core Intrabuilding. The overvoltage protected OD fast Ethernet cable is for indoor and outdoor usage. For lightning surge requirements, see section Lightning surge requirements in the Requirements for Flexi WCDMA BTS Installation and Operation document. The System Module front panel is illustrated in the following figure.
24 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module interfaces
Power Supply RF Module
Power Supply RF Module 2
1
Power Supply RF Module 3
Power Supply BB-EXT Module Transmission interfaces
Circuit breakers RF1
10/100 Eth
10/100 Eth FPMA
RF2
RF3
Extension Module/System Module
EAC
10/100 Eth OVP 1000 Eth
Sync Out
Sync In
OPT-RF 1
Grounding points
OPT-RF 3
OPT-RF2
OPT-EXT2
OPT- EXT1
DN7080615
Figure 10.
Front panel of the System Module
For the location of LEDs, see the System Module LED indications. The location of the DC input connector is illustrated in the following figure.
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
25 (44)
Flexi WCDMA BTS System Module Description
DC input connector
DN70150444
Figure 11.
DC input connector in the System Module
System Module connector pin maps The Sync in connector pin map is presented in the following table.
Table 8.
26 (44)
External synchronization input interface connector (MDR26)
Pin
Signal
Pin
Signal
1
PPS_in+
14
GND
2
PPS_in-
15
nc
3
GPStime_in+
16
GND
4
GPStime_in-
17
nc
5
reserved for future use
18
GND
6
reserved for future use
19
reserved for future use
7
ExtRef2M_in
20
GND
8
nc
21
nc
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module interfaces
Table 8.
External synchronization input interface connector (MDR26) (cont.)
Pin
Signal
Pin
Signal
9
reserved for future use
22
reserved for future use
10
nc
23
nc
11
GPS_control+
24
GPS_control-
12
reserved for future use
25
reserved for future use
13
ExtRef10M_in
26
GND
Signal descriptions: .
.
.
.
.
.
.
PPS_in: Pulse Per Second (1Hz) frequency and time reference (electrically RS-485) GPStime_in: GPS time reference, GPS receiver control in (electrically RS-485 2M_out: 2,048 MHz system clock reference output (electrically G.703) ExtRef2M_in: 2,048 MHz external frequency reference (electrically ITU-T G.703) GPS_control: GPS receiver control out (electrically RS-485) TestWfclk_out: Programmable 100Hz, 50Hz, 25Hz or 12,5Hz (+SFN0 pulse) system frame clock (electrically LVTTL) (GPS power control in REL1) ExtRef10M_in: 10MHz external frequency reference (electrically LVTTL)
See the following figure for the MDR26 connector.
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
27 (44)
Flexi WCDMA BTS System Module Description
Pin 1
DN70416839
Figure 12.
MRD26 connector
The Sync out connector pin map is presented in the following table.
Table 9.
External synchronisation output interface connector (MDR14)
Pin
Signal
Pin
Signal
1
PPS_out+
8
GND
2
PPS_out-
9
HARQ
3
GPStime_out+
10
GND
4
GPStime_out-
11
Testclk_out
5
reserved for future use
12
GND
6
reserved for future use
13
reserved for future use
7
2M_out
14
GND
Signal descriptions: .
2M_out: 2.048 MHz clock reference output (ITU-T G.703/chapter 13) .
.
.
28 (44)
The signal comes from the Flexi transport part, which is locked (PLL) to the Iub interface. The signal in MDR14 is asymmetric: connect the core of the coaxial cable to pin 7 and cable shield to GND (e.g. pin 14).
Testclk_out: 10MHz system clock (LVTTL)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module interfaces
.
.
.
The signal comes from BTS OCXO which is used for air I/F generation => reference for the RF measurement equipment. Note: the BTS OCXO is not in the PLL mode to the Iub, the locking is very loose due to air I/F stability reasons. The signal in MDR14 is asymmetric: connect the core of the coaxial cable to pin 11 and cable shield to GND (e.g. pin 10)
GND: signal ground, for asymmetric signals
.
PPS_out: Pulse Per Second (1Hz) frequency and time reference (electrically RS-485)
.
GPStime_out: GPS time reference (electrically RS-485)
.
TestWfclk_out: Programmable 100Hz, 50Hz, 25Hz or 12,5Hz (+SFN0 pulse) system frame clock (electrically LVTTL)
.
HARQ: reserved signal for research and development testing purposes
.
See the following figure for MDR 14 connector. Pin 1
DN70350833
Figure 13.
MDR14 connector
The Power supply RF module 1-3 connectors pin map is presented in the following table.
Table 10.
DN7084495 Issue 5-0 en 21/01/2008
The Power supply RF module 1-3 connectors (4 X multi-beam)
Pin
Signal
1
V48N
2
V48RTN
# Nokia Siemens Networks
29 (44)
Flexi WCDMA BTS System Module Description
Signal description (one out of four multi-beam connectors shown): V48#: 48VDC power supply
.
See the following figure for Multi-beam XL power supply connector
DN70427485
Figure 14.
Multi-beam XL power supply connector
The 10/100 Eth connector pin map is presented in the following table.
Table 11.
The 10/100 Eth connector (RJ45)
Pin
Signal
1
RX+
2
RX-
3
TX+
4
GND
5
GND
6
TX-
7
GND
8
GND
Signal description: .
The signals of this connector are according to standard 100Base-TX (IEEE 802.3) for MDI-X configuration.
See the following figure for RJ45 connector.
30 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module interfaces
Pin 1
DN70416854
Figure 15.
RJ45
The 10/100 Eth FPMA connector pin map is presented in the following table.
Table 12.
The 10/100 Eth FPMA connector (RJ45)
Pin
Signal
1
RX+
2
RX-
3
TX+
4
AL1
5
AL2
6
TX-
7
GND
8
GND
Singnal description: .
.
The signals of this connector are according to standard 100Base-TX (IEEE 802.3) for MDI-X configuration and as specified below: AL#: Site support alarm inputs 1-2 (electrically TTL)
See the following figure for RJ45 connector.
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
31 (44)
Flexi WCDMA BTS System Module Description
Pin 1
DN70416854
Figure 16.
RJ45
The 10/100 Eth OVP connector pin map is presented in the following table (RJ45).
Table 13.
The 10/100 Eth OVP connector (RJ45)
Pin
Signal
1
RX+
2
RX-
3
TX+
4
GND
5
GND
6
TX-
7
GND
8
GND
Signal description: .
The signals of this connector are according to standard 100Base-TX (IEEE 802.3) for MDI-X configuration.
See the following figure for RJ45 connector.
32 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module interfaces
Pin 1
DN70416854
Figure 17.
RJ45
The 1000 Eth connector pin map is presented in the following table.
Table 14.
The 1000 Eth connector (RJ45)
Pin
Signal
1
BI_D2+
2
BI_D2-
3
BI_D1+
4
BI_D4+
5
BI_D4-
6
BI_D1-
7
BI_D3+
8
BI_D3-
Signal description: .
The signals of this connector are according to standard 1000Base-T (IEEE 802.3) for MDI-X configuration.
See the following figure for RJ45 connector.
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
33 (44)
Flexi WCDMA BTS System Module Description
Pin 1
DN70416854
Figure 18.
RJ45
The EAC connector pin map is presented in the following table.
Table 15.
34 (44)
The EAC connector (MDR36)
Pin
Signal
Pin
Signal
1
EXT_CO0
19
+5V
2
EXT_CO1
20
+5V
3
EXT_CO2
21
+5V
4
EXT_CO3
22
+5V
5
EXT_CO4
23
+5V
6
EXT_CO5
24
+5V
7
EXT_AL0
25
GND
8
EXT_AL1
26
GND
9
EXT_AL2
27
GND
10
EXT_AL3
28
GND
11
EXT_AL4
29
GND
12
EXT_AL5
30
GND
13
EXT_AL6
31
GND
14
EXT_AL7
32
GND
15
EXT_AL8
33
GND
16
EXT_AL9
34
GND
17
EXT_AL10
35
GND
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module interfaces
Table 15.
The EAC connector (MDR36) (cont.)
Pin
Signal
Pin
Signal
18
EXT_AL11
36
GND
Signal description: .
EXT_CO#: BTS External control outputs 1-6 (electrically TTL)
.
EXT_AL#: BTS External alarm inputs 1-12 (electrically TTL)
See the following figure for MDR36 connector. 18
1
36
DN70427458
Figure 19.
MDR36
The DC input connector pin map is presented in the following table.
Table 16.
The DC input connector (Terminal block)
Pin
Signal
1
V48N
2
V48RTN
Signal description: .
V48#: 48VDC power supply
The Grounding connector pin map is presented in the following table.
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
35 (44)
Flexi WCDMA BTS System Module Description
Table 17.
The Grounding connector (Screw terminal).
Signal Description
L2/L3 Description
L1 Description
Ground
N/A
GND
Table 18.
E1/T1/JT1 symmetrical pin map RJ-48C
Pin
Signal
Wire colour
1
RX_Ring
brown
2
RX_Tip
yellow
3
RX_Shield
4
TX_Ring
white
5
TX_Tip
green
6
TX_Shield
7
nc
8
nc
See the following figure for the RJ-48C connector (same as RJ-45). Pin 1
DN70416854
Figure 20.
RJ-48C
The following connectors are optical fibre connectors, and therefore, have no pin maps.
36 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module interfaces
DN7084495 Issue 5-0 en 21/01/2008
.
OPT-RF1
.
OPT-RF2
.
OPT-RF3
.
OPT-EXT1
.
OPT-EXT2
# Nokia Siemens Networks
37 (44)
Flexi WCDMA BTS System Module Description
38 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module LED indications
6
System Module LED indications The System Module has seven tri-colour LEDs on the front panel to indicate the operational status of the module and all fault conditions during operation. See the following figure for the System Module LEDs.
OPT-RF2
OPT-RF3
OPT-RF1
SYSTEM MODULE STATUS
OPT-EXT1
OPT-EXT2
FAN
Figure 21.
System Module LED positions
The LED indications of the System Module are listed and explained in the table below. It is recommended that you read the information on the LED indications carefully. A blinking red LED does not always require removing the module.
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
39 (44)
Flexi WCDMA BTS System Module Description
Table 19.
System Module LEDs (from left to right)
LED
Colour
System Module status
.
Red, blinking: Minor alarm
.
Yellow: Stand-by or blocked
.
.
RF Module 1 fiber connection status
RF Module 2 fiber connection status
RF Module 3 fiber connection status
System Extension Module 1 fiber connection status
System Extension Module 2 fiber connection status
Red: Module self-test or reset (LED red for < 5 seconds) or major alarm or critical alarm
.
.
Fan status
Yellow, blinking: SW download or configuration ongoing, module non-operational Green: Module operational (the cell can be locked in the RNC) Green, blinking: Module is loading software or parameters or local maintenance access when modules are operational
.
Red: Fan fault
.
Green: Fan OK
.
Red: no connection
.
Green: connection OK
.
Yellow: not in use
.
Red: no connection
.
Green: connection OK
.
Yellow: not in use
.
Red: no connection
.
Green: connection OK
.
Yellow: not in use
.
Red: no connection
.
Green: connection OK
.
Yellow: not in use
.
Red: no connection
.
Green: connection OK
.
Yellow: not in use
Tip You can inspect the state of all BTS or transmission-related alarms from the LED on the transmission sub-module.
Note that the FTFA unit has two additional radio-specific LEDs on the front panel.
40 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module as an extension module
7
System Module as an extension module
7.1
System Module as an extension module The System Module can be used as a System Extension Module operating in a baseband extension mode to add channel capacity. In this case, it is connected to the System Module by connecting two optical cables and a DC cable. These items are provided with Flexi System Extension Kit (FSKA). When the System Module is used as a System Extension Module operating in a baseband extension mode, a transmission sub-module is not installed. Instead, a dummy transmission sub-module is installed to provide IP protection. This item is also included in Flexi System Extension Kit (FSKA). When the System Module is used as a System Extension Module operating in a baseband extension mode, external synchronisation input connectors cannot be used. Synchronisation is provided by the System Module. For installation instructions, see the Installing Optional Items document. For commissioning instructions, see the Nokia Flexi WCDMA BTS Commissioning document. When integrating the System Extension Module to Flexi WCDMA BTS, no commissioning is required. Once the System Extension Module has been connected to the System Module and powered up, the auto detection functions of Flexi WCDMA BTS detect the System Extension Module and connect the System Extension Module to the normal operation of the BTS. As for software requirements, the auto detection requires that WN4.0 BTS SW exists and is active both in the System Module and System Extension Module to be connected to.
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
41 (44)
Flexi WCDMA BTS System Module Description
The System Extension Module provides a basic capacity of 32 CE without the channel capacity licence. Enabling more CE capacity of the System Extension module for service requires that the channel capacity licence (RAN912 Channel Capasity LK) with sufficient capacity is downloaded to the BTS.
7.2
FPFA interfaces Power is distributed from Flexi Power Distribution and Fuses (FPFA) to the transmission sub-modules in the System Module. See the following figure for the location of the FPFA.
Transmission sub-module
FPFA
Type Label
DN70424873
Figure 22.
Location of the FPFA and transmission sub-module in the System Module
There are two types of FPFAs available: .
A101 version
.
A102, A103 or later
There are differences between these versions in the inner connections. FPFA inputs and outputs With all FPFA versions, always use busbar input connector (with screw connection) for input connections of the FPFA and when connecting power to the extension module.
42 (44)
# Nokia Siemens Networks
DN7084495 Issue 5-0 en 21/01/2008
System Module as an extension module
The multibeam connectors in the front panel must not be used as input to the FPFA. The multibeam connectors are not hot-plug connectors. Always switch off the power via the on/off switch on the FPFA front panel when connecting or disconnecting the RF or Extension module to the FPFA. Circuit breakers: RF1 RF2 RF3 Extension Module/System Module
RF1
RF2
DC input connector for System Module and Extension Module RF3
EXT
Connector to System Module (located on the bottom)
DN70322858
Figure 23.
FPFA interfaces
The above figure illustrates the System Module core version 101 and 102. Please check the core version from the type label indicated in the previous picture. LED indications for RF1, RF2, RF3 and EXT LEDs (4) on the front panel indicate the state of the circuit breakers (CB) if load (for example the RF Module or the System Extension Module) is connected to FPFA output. When lit, the LED is red. LED on: .
Load connected to FPFA output and CB has tripped
.
Load connected to FPFA output and CB switch pulled to off position
LED off:
DN7084495 Issue 5-0 en 21/01/2008
# Nokia Siemens Networks
43 (44)