Set Advanced Channel Management Parameters of Cell(SET GCELLCHMGAD) Function Use this command to set the advanced channel management parameters of a cell. Note None Parameter Parameter ID
Parameter Name
IDTYPE
Index Type
Parameter Description
Meaning: Type of an index
GUI Value Range: BYNAME(By Name), BYID(By Index)
Actual Value Range: BYNAME, BYID
Unit: None
Default Value: None
Recommended Value: None
Parameter ID
Parameter Name
CELLID
Cell Index
Parameter Description
Meaning: Index of a cell, uniquely identifying a cell in a BSC
GUI Value Range: 0~2047
Actual Value Range: 0~2047
Unit: None
Default Value: None
Recommended Value: None CELLNAME
Cell Name Meaning: Name of a cell, uniquely identifying a cell in a BSC
GUI Value Range: None
Actual Value Range: 1~64 characters
Parameter ID
Parameter Name
Parameter Description
Unit: None
Default Value: None
Recommended Value: None TCHBUSYTHRES
TCH Traffic Busy Threshold Meaning: If the current channel seizure ratio reaches or exceeds this value, the half-rate TCH is assigned preferentially; otherwise, the full-rate TCH is assigned preferentially.
GUI Value Range: 0~100
Actual Value Range: 0~100
Unit: per cent
Default Value: None
Recommended Value: 60 INTERFPRIALLOW
Interf. Priority Allowed
Meaning: Whether to consider
Parameter ID
Parameter Name
Parameter Description
interference priorities during channel assignment
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: YES CHANINTERMESALLOW
Active CH Interf. Meas.Allowed
Meaning: Whether to measure the channel interference during channel assignment. If this parameter is set to NO, the BSC does not measure the channel interference or send an interference indication during channel assignment. If this parameter is set to YES, the BSC measures the channel interference during channel assignment.
GUI Value Range: NO(No),
Parameter ID
Parameter Name
Parameter Description
YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: YES TRXPRIALLOW
Allocation TRX Priority Allowed
Meaning: This parameter specifies whether the TRX priority is considered during channel assignment. When the parameter is set to YES, the smaller the parameter TRX Priority in the command SET GTRXDEV is, the higher priority the TRX is. Under other conditions, channels are preferentially allocated from high-priority TRXs.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Parameter ID
Parameter Name
Parameter Description
Unit: None
Default Value: None
Recommended Value: YES HISPRIOALLOW
History Record Priority Meaning: Whether to consider Allowed history priority records during channel assignment. If this parameter is set to YES, the history priority records are considered. If this parameter is set to NO, the history priority records are not considered.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Parameter ID
Parameter Name
Parameter Description
Recommended Value: YES LOADSHAREALLOW
Balance Traffic Allowed Meaning: If this parameter is set to YES, the channel assignment algorithm II randomly selects the start range for channel traversal; otherwise, the algorithm selects the channel next to the channel assigned last time as the start point of channel traversal.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: YES UPINTERLEVLIMIT
Interf.of UL Level Threshold
Meaning: One of the thresholds to determine whether the uplink interference exists. If the uplink level is not smaller than Interf.of UL Level Threshold
Parameter ID
Parameter Name
Parameter Description
and the uplink quality of the channel is not less than Interf.of UL Qual. Threshold, the uplink interference exists.
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: dB
Default Value: None
Recommended Value: 30 UPINTERFQUALLIMIT
Interf.of UL Qual. Threshold
Meaning: One of the thresholds to determine whether the uplink interference exists. If the uplink level is not smaller than Interf.of UL Level Threshold and the uplink quality of the channel is not less than Interf.of UL Qual. Threshold, the uplink interference exists.
GUI Value Range: 0~70
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: 0~70
Unit: None
Default Value: None
Recommended Value: 40 DLINTERFLEVLIMIT
Interf.of DL Level Threshold
Meaning: Threshold for determining whether downlink interference exists. If the downlink level is equal to or greater than Interf.of DL Level Threshold and the downlink quality level is equal to or greater than Interf.of DL Qual.Threshold, downlink interference exists. The value range 0 to 63 is mapped to the range -110 dBm to -47 dBm.
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: dB
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: 35 DLINTERFQUALLIMIT
Interf.of DL Qual.Threshold Meaning: Threshold for determining whether downlink interference exists. If the downlink level is equal to or greater than Interf.of DL Level Threshold and the downlink quality level is equal to or greater than Interf.of DL Qual.Threshold, downlink interference exists.
GUI Value Range: 0~70
Actual Value Range: 0~70
Unit: None
Default Value: None
Recommended Value: 40 SSLENSD
Filter Length for TCH Level
Meaning: When the network
Parameter ID
Parameter Name
Parameter Description
receives measurement reports, the measurement values in several straight measurement reports are filtered to reflect the radio operating environment for the sake of accuracy. This parameter specifies the number of successive measurement reports that are used to determine the signal strength on traffic/data channels.
GUI Value Range: 1~32
Actual Value Range: TCH:480~15360, step:480; SDCCH:470~15040, step:470
Unit: ms
Default Value: None
Recommended Value: 6 QLENSD
Filter Length for TCH Qual.
Meaning: For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement
Parameter ID
Parameter Name
Parameter Description
reports. This parameter indicates the number of measurement reports used for the filtering of the signal quality on service or data channels. This parameter is used to determine whether interferences exist on channels.
GUI Value Range: 1~32
Actual Value Range: TCH:480~15360, step:480; SDCCH:470~15040, step:470
Unit: ms
Default Value: None
Recommended Value: 6 SSLENSI
Filter Length for SDCCH Level
Meaning: When the network receives measurement reports, the measurement values in several straight measurement reports are filtered to reflect the radio operating environment for the sake of accuracy. The parameter specifies the number of successive measurement
Parameter ID
Parameter Name
Parameter Description
reports that are used to determine the signal strength on signaling channel.
GUI Value Range: 1~32
Actual Value Range: TCH:480~15360, step:480; SDCCH:470~15040, step:470
Unit: ms
Default Value: None
Recommended Value: 2 QLENSI
Filter Length for SDCCH Qual.
Meaning: For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement reports. This parameter indicates the number of measurement reports used for the filtering of the signal quality on signaling channels. This parameter is used to determine whether interferences exist on
Parameter ID
Parameter Name
Parameter Description
channels.
GUI Value Range: 1~32
Actual Value Range: TCH:480~15360, step:480; SDCCH:470~15040, step:470
Unit: ms
Default Value: None
Recommended Value: 2 AMRTCHHPRIORALLOW
AMR TCH/H Prior Allowed
Meaning: Whether to enable the BSC to assign AMR half rate channels preferentially according to the channel types allowed by the MSC and the current TCH seizure ratio of the cell
GUI Value Range: OFF(Off), ON(On)
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: OFF, ON
Unit: None
Default Value: None
Recommended Value: ON AMRTCHHPRIORLOAD
AMR TCH/H Prior Cell Load Meaning: Load threshold for Threshold assigning half rate channels preferentially. If the current TCH seizure ratio of the cell is greater than this threshold, AMR half rate channels are assigned preferentially.
GUI Value Range: 0~99
Actual Value Range: 0~99
Unit: per cent
Default Value: None
Parameter ID
Parameter Name
Parameter Description
Recommended Value: 55 TCHTRICBUSYOVERLAYTHR
Tch Traffic Busy Overlay Threshold
Meaning: The BSC assigns channels in the overlaid subcell to the MS in a concentric cell. If the channel seizure ratio of overlaid subcell is greater than the value of this parameter, half-rate channels are assigned. Otherwise, full-rate channels are assigned. Channel seizure ratio = (Num. of busy TCHF + Num. of busy TCHH/2)/(Num. of available TCHF + Num. of available TCHH /2) x 100%. This parameter is valid for the concentric cell. When the Allow Rate Selection Based on Overlaid/Underlaid Subcell Load is set to Yes, the TCH Traffic Busy Threshold (%) is invalid for the concentric cell.
GUI Value Range: 0~100
Actual Value Range: 0~100
Unit: per cent
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: 70 TCHTRIBUSYUNDERLAYTHR
Tch Traffic Busy Underlay Threshold
Meaning: Threshold for determining that the underlaid subcell is busy. The BSC assigns channels in the underlaid subcell to the MS in a concentric cell. When Allow Rate Selection Based on Overlaid/Underlaid Subcell Load is set to YES, half-rate channels are assigned if the channel seizure ratio in the underlaid subcell exceeds the value of this parameter, and full-rate channels are assigned if the channel seizure ratio in the underlaid subcell does not exceed the value of this parameter.
GUI Value Range: 0~100
Actual Value Range: 0~100
Unit: per cent
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: 60 HRIUOLDRATESELALLOW
Load of UL-OL Cells Rate Meaning: Whether to enable the Select Allowed BSC to assign half or full rate channels to MSs according to the channel seizure ratio in the overlaid and underlaid subcells
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: YES UPRXLEVSMOOTHPARA
Smooth Factor of Uplink Meaning: After the existing Received Level uplink receive level, uplink receive level after the previous optimization, and the value of this parameter are weight-
Parameter ID
Parameter Name
Parameter Description
averaged, the uplink receive level after the optimization at this time is obtained and used for determing the difference between the uplink receive levels.
GUI Value Range: 1~10
Actual Value Range: 0.1~1, step:0.1
Unit: None
Default Value: None
Recommended Value: 6 UPRXLEVLASTTIME
Duration of Uplink Meaning: If the difference Received Level between uplink receive levels Differ of calls within the same timeslot is greater than Offset of the difference between uplink received levels for P seconds among N seconds, the call with weak uplink receive level within the timeslot will be handed over to another timeslot. This parameter corresponds to
Parameter ID
Parameter Name
Parameter Description
P in the P/N criterion.
GUI Value Range: 1~16
Actual Value Range: 1~16
Unit: s
Default Value: None
Recommended Value: 4 UPRXLEVSTATICTIME
Observe Time of UL RX Level Difference
Meaning: If the difference between uplink receive levels of calls within the same timeslot is greater than Offset of the difference between uplink received levels for P seconds among N seconds, the call with weak uplink receive level within the timeslot will be handed over to another timeslot. This parameter corresponds to N in the P/N criterion.
GUI Value Range: 1~16
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: 1~16
Unit: s
Default Value: None
Recommended Value: 5 QTRUPWRSHARE
Multi-Density TRX Power Sharing
Meaning: Whether to use the statistical multiplexing algorithm for multi-density power
GUI Value Range: NONE(None), DYNAMIC(Dynamic power sharing)
Actual Value Range: NONE, DYNAMIC
Unit: None
Default Value: None
Parameter ID
Parameter Name
Parameter Description
Recommended Value: NONE MCPAOPTALG
MCPA Optimization Switch
Meaning: If the MCPA Optimization Switch is turned on, the MCPA priority update mode is adjusted.
GUI Value Range: OFF(Off), ON(On)
Actual Value Range: ON, OFF
Unit: None
Default Value: None
Recommended Value: OFF QTRUDNPWRSTATTIME
Qtru Down Power Meaning: The P/N criteria is Inadequate Stat used to determine low downlink Time power for multi-density carriers. If the downlink power of a multi-density carrier remains low during a consecutive P seconds out of N seconds, the downlink power of the multi-density carrier is considered low. This parameter
Parameter ID
Parameter Name
Parameter Description
corresponds to the N in the P/N criteria.
GUI Value Range: 1~16
Actual Value Range: 1~16
Unit: s
Default Value: None
Recommended Value: 5 QTRUDNPWRLASTTIME
Qtru Down Power Meaning: The P/N criteria is Inadequate Last used to determine low downlink Time power for multi-density carriers. If the downlink power of a multi-density carrier remains low during a consecutive P seconds out of N seconds, the downlink power of the multi-density carrier is considered low. This parameter corresponds to the P in the P/N criteria.
GUI Value Range: 1~16
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: 1~16
Unit: s
Default Value: None
Recommended Value: 3 PWRPRIORALLOW
Power Priority Allowed
Meaning: When this parameter is set to YES, The BSC preferentially uses the TRX with good power-saving performance according to the TRX power priority reported by the BTS. Smaller priority value indicates better power saving quality. If the priority is of a great value, the BTS closes TRXs late.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: YES TIGHTBCCHASSMAINBCCHLEV
Level Thresh for Assign BCCH Under TBCCH
Meaning: During channel assignment, the assignment of channels on the BCCH TRXs depends on the uplink receive level, quality, and non-BCCH load. The TCHs are preferentially assigned on the BCCH TRXs if the following conditions are met: 1. The uplink receive level after filtering is higher than Level Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH. 2. The uplink receive quality level after filtering is lower than Quality Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH. 3. The non-BCCH load is higher than Intracell Non Main BCCH Load Threshold of TIGHT BCCH.
GUI Value Range: 0~63
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: 0~63
Unit: dB
Default Value: None
Recommended Value: 30 TIGHTBCCHASSMAINBCCHQUAL
Quality Thresh for Assign BCCH Under TBCCH
Meaning: During channel assignment, the assignment of channels on the BCCH TRXs depends on the uplink receive level, quality, and non-BCCH load. The TCHs are preferentially assigned on the BCCH TRXs if the following conditions are met: 1. The uplink receive level after filtering is higher than Level Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH. 2. The uplink receive quality level after filtering is lower than Quality Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH. 3. The non-BCCH load is higher than Intracell Non Main BCCH Load Threshold
Parameter ID
Parameter Name
Parameter Description
of TIGHT BCCH.
GUI Value Range: 0~7
Actual Value Range: 0~7
Unit: None
Default Value: None
Recommended Value: 1 CHPWRINSUFFALLOWED
Channel Assign Allow for Meaning: Whether to allow a Insuff Power multi-density TRX board, that uses the dynamic power sharing algorithm to assign channels, to assign a channel to an MS when the remaining power on the multi-density TRX board is less than the power required by the MS. If this parameter is set to YES, a multi-density TRX board that uses the dynamic power sharing algorithm to assign channels cannot assign a channel to an MS when the remaining power on the multidensity TRX board is less than the power required by the MS.If this parameter is set to NO, a
Parameter ID
Parameter Name
Parameter Description
multi-density TRX board that uses the dynamic power sharing algorithm to assign channels can assign a channel to an MS when the remaining power on the multi-density TRX board is less than the power required by the MS.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: NO FREQLOADSHARETRAFFTHRSH
GSM900 Band Traffic Load Share Threshold
Meaning: Threshold for load sharing in the 900 MHz frequency band. Assume that an MS supports multiple subbands in the 900 MHz frequency band. If the cell load is equal to or less than this threshold, the BSC does not consider the priority levels of the P-GSM, E-GSM, and R-
Parameter ID
Parameter Name
Parameter Description
GSM sub-bands during channel assignment. If the cell load is greater than this threshold, the BSC assigns channels according to the priority levels of the P-GSM, E-GSM, and RGSM sub-bands. That is, if the MS supports the P-GSM, EGSM, and R-GSM sub-bands and the cell is configured with the TRXs in the P-GSM, EGSM, and R-GSM sub-bands, the BSC assigns the channels in the TRXs of the R-GSM subband preferentially.
GUI Value Range: 0~100
Actual Value Range: 0~100
Unit: per cent
Default Value: None
Recommended Value: 25 NAMRLFRMTRXALLOWED
Assign NonAMR User Loose Fre. Reuse TRX
Meaning: Whether to preferentially allocate loose multiplexing frequencies to
Parameter ID
Parameter Name
Parameter Description
non-AMR users
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: NO IBCAALLOWED
IBCA Allowed Meaning: Whether to enable the IBCA algorithm
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: NO IBCAUSRDYNCMEASURENCELL
IBCA User Dyn Measure Neighbor Cell
Meaning: Whether a single IBCA MS can dynamically measure the neighboring cells. When this parameter is set to YES, the neighboring cells where IBCA Dynamic Measure Neighbor Cell Flag is set to YES are dynamically measured. Dynamic measurement on neighboring cells is mutually exclusive to directed retry. When this parameter is set to YES, it is recommended that Direct Retry be set to NO.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Parameter ID
Parameter Name
Parameter Description
Recommended Value: NO IBCAUSEDIUOSUBLAY
IUO IBCA Allowed
Meaning: Whether to enable the IBCA algorithm for the overlay and underlay of an IUO cell
GUI Value Range: NO(Disabled in OL and UL subcell), UNDER(Enabled in UL subcell), INNER( Enabled in OL subcell), YES(Enabled in OL and UL subcell)
Actual Value Range: NO, UNDER, INNER, YES
Unit: None
Default Value: None
Recommended Value: UNDER IBCASOFTBLKSWITCH
IBCA Soft Block Switch
Meaning: Whether to deny the access of a call when none of the MAIO evaluation results meets the C/I ratio requirement of the call during channel
Parameter ID
Parameter Name
Parameter Description
assignment
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: NO IBCAFRSOFTBLKTHRD
IBCA FR/EFR Soft Block Threshold
Meaning: Minimum C/I ratio that IBCA FR/EFR services allow. An idle channel can be assigned to such a service only when the C/I ratio of the idle channel is greater than this threshold. In addition, a new call associated with such a service can be established only when the call does not decrease the C/I ratio of the established calls to a value less than this threshold.
Parameter ID
Parameter Name
Parameter Description
GUI Value Range: 0~23
Actual Value Range: 0~23
Unit: dB
Default Value: None
Recommended Value: 10 IBCAHRSOFTBLKTHRD
IBCA HR Soft Block Threshold
Meaning: Minimum C/I ratio that IBCA HR services allow. An idle channel can be assigned to such a service only when the C/I ratio of the idle channel is greater than this threshold. In addition, a new call associated with such a service can be established only when the call does not decrease the C/I ratio of the established calls to a value less than this threshold.
GUI Value Range: 0~23
Actual Value Range: 0~23
Parameter ID
Parameter Name
Parameter Description
Unit: dB
Default Value: None
Recommended Value: 13 IBCAAFRSOFTBLKTHRD
IBCA AMR FR Soft Block Meaning: Minimum C/I ratio Threshold that IBCA AMR FR services allow. An idle channel can be assigned to such a service only when the C/I ratio of the idle channel is greater than this threshold. In addition, a new call associated with such a service can be established only when the call does not decrease the C/I ratio of the established calls to a value less than this threshold.
GUI Value Range: 0~23
Actual Value Range: 0~23
Unit: dB
Default Value: None
Parameter ID
Parameter Name
Parameter Description
Recommended Value: 4 IBCAAHRSOFTBLKTHRD
IBCA AMR HR Soft Block Threshold
Meaning: Minimum C/I ratio that IBCA AMR HR services allow. An idle channel can be assigned to such a service only when the C/I ratio of the idle channel is greater than this threshold. In addition, a new call associated with such a service can be established only when the call does not decrease the C/I ratio of the established calls to a value less than this threshold.
GUI Value Range: 0~23
Actual Value Range: 0~23
Unit: dB
Default Value: None
Recommended Value: 10 IBCAWAFRSOFTBLKTHRD
IBCA WAMR FR Soft Block
Meaning: The lowest C/I ratio
Parameter ID
Parameter Name
Parameter Description
Threshold that can be tolerated by IBCA WAMR FR. The C/I ratio of an idle channel must be larger than this parameter. Otherwise, it cannot be assigned. In addition, the system does not allow a newly-established call causing the C/I ratio of existing calls to be lower than this parameter.
GUI Value Range: 0~23
Actual Value Range: 0~23
Unit: dB
Default Value: None
Recommended Value: 5 IBCASOFTBLKSAICOFF
IBCA Soft Block SAIC Offset
Meaning: MSs that support SAIC can tolerate a lower carrier-to-interference ratio. This variable indicates the downward adjustment step of the soft blocking threshold of SAIC MSs.
Parameter ID
Parameter Name
Parameter Description
GUI Value Range: 0~23
Actual Value Range: 0~23
Unit: dB
Default Value: None
Recommended Value: 1 IBCAMAXINTFSRCNUM
IBCA Max. Interference Source Num.
Meaning: The IBCA interference evaluation process only considers the interference of the strongest N existing calls on the newly-established call being evaluated. This parameter corresponds to the abovementioned N.
GUI Value Range: 5~40
Actual Value Range: 5~40
Unit: None
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: 20 IBCADLPATHLOSSOFF
IBCA Downlink Path Loss Offset
Meaning: Difference between uplink and downlink path losses, which is used to estimate the downlink path loss of a call when the downlink path loss cannot be computed directly according to a measurement report. This parameter is configured according to the combined loss and hierarchical dual-antenna gain (3 dB) of the BTS. IBCA Downlink Path Loss Offset = combined loss of BTS + hierarchical dual-antenna gain of BTS (3 dB)
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: dB
Default Value: None
Parameter ID
Parameter Name
Parameter Description
Recommended Value: 7 IBCAIUOPATHLOSSOFF
IBCA IUO Path Loss Offset Meaning: In an IUO cell (or a CoBCCH cell), the path loss of an MS to the serving cell or a neighboring cell measured on the underlay is used together with this parameter to estimate the path loss on the overlay. IUO path loss compensation = Combiner insert loss difference + Path loss difference due to the use of different antennas + Path loss difference due to different frequency selectivity. This value is calculated based on the IUO level values measured by field engineers. When different antennas are used by the overlay and underlay, the level must be measured at multiple locations.
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: dB
Default Value: None
Parameter ID
Parameter Name
Parameter Description
Recommended Value: 4 IBCASCELLPATHLOSS
IBCA Service Cell Pathloss
Meaning: Use this parameter when the path loss of an MS to serving cells cannot be measured based on the existing measurement results
GUI Value Range: 0~160
Actual Value Range: 0~160
Unit: dB
Default Value: None
Recommended Value: 110 IBCAPATHLOSSOFF
IBCA Pathloss Offset
Meaning: When the path loss of an MS to a neighboring cell cannot be measured based on the existing measurement results, it is estimated based on the path loss of the MS to the serving cell plus the IBCA path loss offset.
Parameter ID
Parameter Name
Parameter Description
GUI Value Range: 0~50
Actual Value Range: 0~50
Unit: dB
Default Value: None
Recommended Value: It is recommended that you set the path loss offset of layer 1 neighboring cells of the serving cell to 15 dB and that of other neighboring cells to 25 dB. IBCACALLINFOFILTERLEN
IBCA Call Information Filter
Meaning: Number of measurement reports sampled for averaging path loss. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to average the measured values in several successive measurement reports to reflect the radio environment.
GUI Value Range: 1~4
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: TCH:480~1920, step:480; SDCCH:470~1880, step:470
Unit: ms
Default Value: None
Recommended Value: 4 LOOSESDCCHLOADTHRED
IBCA Loose Trx SDCCH Meaning: When the load of an Load Threshold SDCCH on the TRX that is in loose frequency reuse and is in the compatible band of the BCCH is lower than this threshold, the SDCCH is preferably allocated.
GUI Value Range: 0~100
Actual Value Range: 0~100
Unit: per cent
Default Value: None
Parameter ID
Parameter Name
Parameter Description
Recommended Value: 80 TIGHTSDCCHRXLEVTHRED
IBCA Tight Trx SDCCH Rxlev Meaning: If the SDCCH load Threshold on the TRXs of the compatible BCCH in loose frequency reuse pattern is greater than the IBCA Loose Trx SDCCH Load Threshold, and when the uplink receive level from the MS to the BTS is greater than the threshold, the SDCCHs on the TRXs of the compatible non-BCCH are preferentially assigned. Otherwise, the SDCCHs on the TRXs of the compatible BCCH are preferentially assigned.
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: dB
Default Value: None
Recommended Value: 40
Parameter ID
Parameter Name
WAITSDCCHIDLETIMER
IBCA Wait SDCCH Idle Timer
Parameter Description
Meaning: When the dynamic PDCH needs to use MAIO of the SDCCH, the SDCCH is not allowed to be assigned to new calls within the value of the parameter. After the timer expires, check whether the SDCCH is idle. If the SDCCH is idle, MAIO of the SDCCH is allowed to be preempted. If the channel is not idle, the MAIO is not allowed to be preempted.
GUI Value Range: 0~60
Actual Value Range: 0~60
Unit: s
Default Value: None
Recommended Value: 4 IBCAICDMSWITCH
IBCA ICDM Switch
Meaning: Whether to enable the ICDM algorithm for the cell. The ICDM algorithm helps to improve the precision in estimating the path loss of an IBCA neighbor cell and to increase the efficiency of the
Parameter ID
Parameter Name
Parameter Description
IBCA algorithm.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: YES IBCAPLFILTFACTOR
IBCA Path Lose Filter Factor
Meaning: Considers the influence of history path loss information during the calculation of the ICDM algorithm path loss. The smaller the filtering coefficient, the smaller the influence of history path loss; on the other hand, the larger the filtering coefficient, the larger the influence of history path loss.
GUI Value Range: 0~10
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: 0~10
Unit: None
Default Value: None
Recommended Value: 6 IBCANCELLPATHLOSSESTIMATE
IBCA Pathloss Est of Non. MR Meaning: Estimates the receive Ncell level of the unmeasured IBCA neighboring cells. When a consecutive IBCA Non Measurement Ncell Stat. Num measurement reports cover less than six neighboring cells (or the number of the reported neighboring cells is smaller than that of the actually configured neighboring cells), this parameter is used to estimate the receive level of the unmeasured IBCA neighboring cells. The estimated value is IBCA Pathloss Est of Non. MR Ncell. Otherwise, the signal strength of the unmeasured IBCA neighboring cells is the signal strength of the measured neighboring cells (including non-IBCA neighboring cells) subtracted by IBCA RxLev Offset.
Parameter ID
Parameter Name
Parameter Description
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: dB
Default Value: None
Recommended Value: 0 IBCANONMEANCELLSTATNUM
IBCA Non Measurement Ncell Stat. Num
Meaning: Estimates the receive level of the unmeasured IBCA neighboring cells. When a consecutive IBCA Non Measurement Ncell Stat. Num measurement reports cover less than six neighboring cells (or the number of the reported neighboring cells is smaller than that of the actually configured neighboring cells), this parameter is used to estimate the receive level of the unmeasured IBCA neighboring cells. The estimated value is IBCA Pathloss Est of Non. MR Ncell. Otherwise, the signal strength of the unmeasured IBCA neighboring cells is the signal strength of the measured neighboring cells (including non-IBCA
Parameter ID
Parameter Name
Parameter Description
neighboring cells) subtracted by IBCA RxLev Offset.
GUI Value Range: 0~16
Actual Value Range: 0~16
Unit: None
Default Value: None
Recommended Value: 4 IBCAMAIOUSMTD
IBCA MAIO Using Method
Meaning: Determines the MAIO selection method for each timeslot. The Optimal MAIO policy selects the optimal MAIO being evaluated, while the Random MAIO policy randomly selects a MAIO out of qualified MAIOs.
GUI Value Range: 0(Max. optimized MAIO), 1(Randomization MAIO)
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: 0, 1
Unit: None
Default Value: None
Recommended Value: 0 IBCATARGETCIRTHRSH
IBCA MAIO Target C/I Threshold
Meaning: Whether a MAIO meets the access requirement. When the C/I ratio of a MAIO is higher than this threshold, the MAIO can be assigned to the call being processed.
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: None
Default Value: None
Parameter ID
Parameter Name
Parameter Description
Recommended Value: 20 IBCAINITPCRXLEVDLOFFSET
IBCA Init. Power Control RexLevDL Offset
Meaning: Adds a specified offset to the downlink target receive level when power control algorithm III is used to calculate the initial transmit power of a BTS in the IBCA function
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: dB
Default Value: None
Recommended Value: 0 IBCAINITPCRXLEVULOFFSET
IBCA Init. Power Control RexLevUL Offset
Meaning: Adds a specified offset to the uplink target receive level when power control algorithm III is used to calculate the initial transmit power of an MS in the IBCA function
Parameter ID
Parameter Name
Parameter Description
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: dB
Default Value: None
Recommended Value: 0 IBCAINITPCRXQUALDLOFFSET
IBCA Init. Pwr Ctrl Rx Qual Meaning: Adds a specified DL Offset offset to the downlink target receive quality when power control algorithm III is used to calculate the initial transmit power of a BTS in the IBCA function
GUI Value Range: 0~22
Actual Value Range: 0~22
Unit: dB
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: 0 IBCAINITPCRXQUALULOFFSET
IBCA Init. Pwr Ctrl Rx Qual Meaning: Adds a specified UL Offset offset to the uplink target receive quality when power control algorithm III is used to calculate the initial transmit power of an MS in the IBCA function
GUI Value Range: 0~22
Actual Value Range: 0~22
Unit: dB
Default Value: None
Recommended Value: 0 LOWRXLEVOLFORBIDSWITCH
Allocate OL Channel Based on RX Level
Meaning: Whether to assign overlay channels in an IUO cell based on the receive level
Parameter ID
Parameter Name
Parameter Description
conditions
GUI Value Range: OFF(Off), ON(On)
Actual Value Range: OFF, ON
Unit: None
Default Value: None
Recommended Value: You are advised to disable this function in the co-BCCH cell with the inter-site distance not more than 1500m. ASSOLRXLEVOFFSET
Assign to Overlayer RxLev Offset
Meaning: Offset relative to the level threshold for determining whether to assign a channel in the overlaid subcell
GUI Value Range: 0~61
Actual Value Range: 0~61
Parameter ID
Parameter Name
Parameter Description
Unit: dB
Default Value: None
Recommended Value: 35 HOOLRXLEVOFFSET
Handover to Overlayer RxLev Offset
Meaning: If the cell is an enhanced concentric cell, this parameter with the current downlink received signal level and UtoO HO Received Level Threshold determines whether to assign a channel in the underlaid subcell to the intraBSC incoming handover to the concentric cell or intra-BSC inter-cell handover. If the cell is an ordinary concentric cell, this parameter with the current downlink received signal level, RX_LEV Threshold, and RX_LEV Hysteresis determines whether to assign a channel in the underlaid subcell to the intraBSC incoming handover to the concentric cell or intra-BSC inter-cell handover.
GUI Value Range: 0~61
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: 0~61
Unit: dB
Default Value: None
Recommended Value: 32 IBCASUBCHNHANDOVERALLOWED
IBCA SubChannel Handover Allowed
Meaning: Whether the handover of the calls on the single channels is allowed (single channels are the two half-rate sub-channels on a timeslot, in which only one is in the occupied state) when single channels are to be adjusted to a full-rate channel. When this parameter is set to ON, the handover of the calls on the single channels is allowed; if this parameter is set to OFF, the handover of the calls on the single channels is not allowed. This parameter is valid only when the IBCA algorithm is enabled and full rate is preferred for the newly established call.
GUI Value Range: OFF(Not Allowed), ON(Allowed)
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: OFF, ON
Unit: None
Default Value: None
Recommended Value: OFF IBCAFORCEDBTSSYNCALLOWED
IBCA Forced BTS Synchronizatio n Allowed
Meaning: Whether the IBCA forced BTS synchronization is allowed. When this parameter is set to YES, the synchronization procedure is performed even though the BTSs are insynchronous. When this parameter is set to NO, the existing procedure, either the synchronization procedure or the out-of-synchronization procedure, is performed as required. Note that the synchronization status of the IBCA neighboring cells is determined by the internal software parameters of the IBCA neighboring cells, that is, if this parameter in IBCA neighboring cells is set to YES, the IBCA neighboring cells are considered to be always synchronous; otherwise, the IBCA neighboring cells are considered to be out of
Parameter ID
Parameter Name
Parameter Description
synchronization.
GUI Value Range: OFF(Not Allowed), ON(Allowed)
Actual Value Range: OFF, ON
Unit: None
Default Value: None
Recommended Value: OFF IBCAFLEXTSCALLOWED
IBCA Flexible TSC Allowed
Meaning: Whether the IBCA flexible TSC function is enabled. When this parameter is set to NO, the flexible TSC function is disabled and the configured TSC is used. When the BTS supports Flex TSC and this parameter is set to YES, the flexible TSC function is enabled.
GUI Value Range: OFF(Not Allowed), ON(Allowed)
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: OFF, ON
Unit: None
Default Value: None
Recommended Value: OFF IBCAASSWAITMEASURERPTTIME
IBCA Assign Waiting Mr Time
Meaning: Length of the timer for a new call to wait for the measurement report (MR) on the signaling channel when dynamic measurement of the BA2 list is enabled during assignment. If this parameter is set to 0, dynamic measurement of the BA2 list is not enabled during assignment.
GUI Value Range: 0~20
Actual Value Range: 0~10, Step: 0.5
Unit: s
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: 4 IBCANHOASSWAITMEASURERPTTIM E
IBCA Natural HO Waiting Mr Meaning: Length of the timer Time for a call to measure the path loss in the neighboring cell with strong interference of the target cell. The call to be handed over needs to measure the path loss before initiating the handover to the target cell when dynamic measurement of the BA2 list is enabled during the normal handover. When this parameter is set to 0, dynamic measurement of the BA2 list is not enabled in the normal handover, and the parameter "Wait Time for Valid MRs in IBCA HO" is invalid.
GUI Value Range: 0~20
Actual Value Range: 0~10, Step: 0.5
Unit: s
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: 5 IBCAEHOASSWAITMEASURERPTTIM E
IBCA Urgent HO Waiting Mr Meaning: Length of the timer Time for a call to measure the path loss in the neighboring cell with strong interference of the target cell. The call to be handed over needs to measure the path loss before initiating the handover to the target cell when dynamic measurement of the BA2 list is enabled during the emergency handover. When this parameter is set to 0, dynamic measurement of the BA2 list is not enabled in the emergency handover, and the parameter "Wait Time for Valid MRs in IBCA HO" is invalid.
GUI Value Range: 0~20
Actual Value Range: 0~10, Step: 0.5
Unit: s
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: 0 IBCAHOASSWAITMEASURERPTTIME
IBCA HO Waiting Effective Mr Time
Meaning: Length of the timer for a call to wait for other valid MRs after receiving the first valid MR of the target cell if dynamic measurement of the BA2 list is enabled during handover. When this parameter is set to 0, the call does not wait for other MRs after receiving the first MR of the target cell.
GUI Value Range: 0~20
Actual Value Range: 0~10, Step: 0.5
Unit: s
Default Value: None
Recommended Value: 2
Parameter ID
Parameter Name
CIRESTVALUE
C/I Estimate Value
Parameter Description
Meaning: This parameter specifies the estimated carrierto-interference ratio of a new call. It is used for the Huawei power control algorithm III to calculate the power of the call.
GUI Value Range: 0~22
Actual Value Range: 0~22
Unit: dB
Default Value: None
Recommended Value: 22 IBCANEWCALLCIROFFSET
Target CIR Offset of IBCA Meaning: When the IBCA New Call algorithm is enabled, this parameter is used to calculate the target CIR of a new call. The formula is as follows: Target CIR of a new call = Target CIR in use + Target CIR Offset of IBCA New Call
GUI Value Range: 0~30
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: 0~30
Unit: dB
Default Value: None
Recommended Value: 7 IBCAOPRREVISEFACTOR
Corrected Factor of IBCA Meaning: When the IBCA Priority algorithm is enabled and the HSN is not 0, the IBCA priority and the SDCCH/PDCH priority are divided by this corrected factor respectively to reduce the weight of IBCA priority. In addition, the priority of the interference band is considered.
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: None
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: 0 IBCACALLTARGETCIROFFSET
Target CIR Offset of IBCA Meaning: When the IBCA Set-up Call algorithm is enabled, this parameter is used to calculate the target CIR of an existing call. The formula is as follows: Target CIR of an existing call = Target CIR in use + Target CIR Offset of IBCA Set-Up Call.
GUI Value Range: 0~14
Actual Value Range: 0~14
Unit: dB
Default Value: None
Recommended Value: 4 IBCACALLSOFTBLOCKTHOFFSET
IBCA Set-up Call Soft Block Meaning: When the IBCA Threshold algorithm is enabled, this Offset parameter is used to calculate
Parameter ID
Parameter Name
Parameter Description
the actual soft blocking threshold of an existing call. The formula is as follows: Actual soft blocking threshold of an existing call = Configured soft blocking threshold of an existing call - IBCA Set-up Call Soft Block Threshold Offset.
GUI Value Range: 0~14
Actual Value Range: 0~14
Unit: dB
Default Value: None
Recommended Value: 0 IBCAICDMRELEVOFFSET
IBCA ICDM Initial Level Offset
Meaning: In the ICDM matrix algorithm, the signal strength (0-63) is divided into 10 levels. The signal strength that is smaller than or equal to the value of this parameter is at the initial level.
Parameter ID
Parameter Name
Parameter Description
GUI Value Range: 0~31
Actual Value Range: 0~31
Unit: dB
Default Value: None
Recommended Value: 10 CELLOPPWRGRP
Cell Operator Power Group
Meaning: Power of each passage on the MRRU in the cell. When multiple operators are configured on an MRRU, the parameter specifies the power of each operator on the MRRU.
GUI Value Range: OP1(Operator 1), OP2(Operator 2), OP3(Operator 3), OP4(Operator 4), NONE(Not Shared)
Actual Value Range: OP1, OP2, OP3, OP4, NONE
Parameter ID
Parameter Name
Parameter Description
Unit: None
Default Value: None
Recommended Value: 255 LOADSTATYPE
Type of Cell Load Calculation
Meaning: This parameter specifies whether the dynamic PDCHs that have been converted into the PDCHs are considered during the calculation of the current cell load.
GUI Value Range: NOTSTADYNPDCH(Not count dynamic PDCH), DYNPDCHASOCCUPY(Coun t dynamic PDCH(Occupy)), DYNPDCHASIDLE(Count dynamic PDCH(Idle))
Actual Value Range: NOTSTADYNPDCH, DYNPDCHASOCCUPY, DYNPDCHASIDLE
Unit: None
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: DYNPDCHASIDLE
Example To set the advanced channel management parameters of the cell (Index Type = BYID; Cell Index = 0; TCH Traffic Busy Threshold = 100), run the following command: SET GCELLCHMGAD: IDTYPE=BYID, CELLID=0, TCHBUSYTHRES=100;