Set Basic Parameters of Cell(SET GCELLBASICPARA) Function Use this command to modify the basic Parameters of the GSM internal cell. Note 1. The cell can support GPRS only when it is configured with the PCU. 2. If the cell supports the adjacent cell of EDGE, NC2, NACC, PACKET SI or PCU64, it must support GPRS. 3. If the cell is modified to not support GPRS, it will not support EDGE, NC2, NACC, PACKET SI or PCU64 adjacent cell. Parameter Parameter ID
Parameter Name
IDTYPE
Index Type
Parameter Description
Meaning: Type of an index
GUI Value Range: BYNAME(By Name), BYID(By Index)
Actual Value Range: BYNAME, BYID
Unit: None
Default Value: None
Parameter ID
Parameter Name
Parameter Description
Recommended Value: None CELLID
Cell Index Meaning: Index of a cell, uniquely identifying a cell in a BSC
GUI Value Range: 0~2047
Actual Value Range: 0~2047
Unit: None
Default Value: None
Recommended Value: None CELLNAME
Cell Name Meaning: Name of a cell, uniquely identifying a cell in a BSC
GUI Value Range: None
Actual Value Range: 1~64 characters
Parameter ID
Parameter Name
Parameter Description
Unit: None
Default Value: None
Recommended Value: None LAYER
Layer of The Cell
Meaning: Layer where a cell is located. The network designed by Huawei has four layers: Umbrella (layer 4), Macro (layer 3), Micro (layer 2), and Pico(layer 1). Each layer can be set with 16 priorities.
GUI Value Range: 1, 2, 3, 4
Actual Value Range: 1, 2, 3, 4
Unit: None
Default Value: None
Recommended Value: 3 PRIOR
Cell Priority Meaning: This parameter controls handover between cells at the same layer. Generally,
Parameter ID
Parameter Name
Parameter Description
the cells at the same layer are set with the same priority. If the cells at the same layer have different priorities, a cell with a smaller priority value has a higher priority.
GUI Value Range: PRIOR-1(Priority-1), PRIOR-2(Priority-2), PRIOR-3(Priority-3), PRIOR-4(Priority-4), PRIOR-5(Priority-5), PRIOR-6(Priority-6), PRIOR-7(Priority-7), PRIOR-8(Priority-8), PRIOR-9(Priority-9), PRIOR-10(Priority-10), PRIOR-11(Priority11), PRIOR-12(Priority-12), PRIOR13(Priority-13), PRIOR-14(Priority-14), PRIOR-15(Priority-15), PRIOR-16(Priority16)
Actual Value Range: PRIOR-1, PRIOR-2, PRIOR-3, PRIOR-4, PRIOR-5, PRIOR-6, PRIOR-7, PRIOR-8, PRIOR-9, PRIOR-10, PRIOR-11, PRIOR-12, PRIOR-13, PRIOR14, PRIOR-15, PRIOR-16
Unit: None
Default Value: None
Recommended Value: None MAXTA
Max TA Meaning: This parameter specifies the actual coverage area of a cell. After
Parameter ID
Parameter Name
Parameter Description
receiving the channel request message or handover access message, the BTS determines whether the channel assignment or handover is performed in the cell by comparing the TA and the value of this parameter. The value of this parameter is determined by that of Cell Extension Type in the ADD GCELL command.
GUI Value Range: 0~255
Actual Value Range: 0~255
Unit: None
Default Value: None
Recommended Value: In Normal cell,the recommended value is 62;in Double Timeslot Extension Cell,the recommended value is 219. FRDLDTX
FR Use Downlink DTX Meaning: Whether the downlink discontinuous transmission (DTX) function is enabled for full rate (FR) calls. This function is also restricted by the DTX switch in the MSC. If the MSC allows the downlink DTX for calls and the value of this parameter(FRDLDTX) is YES, the downlink DTX is enabled for FR calls of
Parameter ID
Parameter Name
Parameter Description
cells.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: YES HRDLDTX
HR Use Downlink DTX Meaning: Whether the downlink DTX function is enabled for half rate (HR) calls. This function is also restricted by the DTX switch in the MSC. If the MSC allows the downlink DTX for calls and the value of this parameter(HRDLDTX) is YES, the downlink DTX is enabled for HR calls of cells.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Parameter ID
Parameter Name
Parameter Description
Unit: None
Default Value: None
Recommended Value: YES ENCRY
Encryption Algorithm
Meaning: Encryption algorithm supported by the BSS side
GUI Value Range: A5/0, A5/1, A5/2, A5/3, A5/4, A5/5, A5/6, A5/7
Actual Value Range: A5/0, A5/1, A5/2, A5/3, A5/4, A5/5, A5/6, A5/7
Unit: None
Default Value: None
Recommended Value: A5/0-1&A5/10&A5/2-0&A5/3-0&A5/4-0&A5/50&A5/6-0&A5/7-0 RXMIN
Minum Access RXLEV
Meaning: Minimum received signal level of
Parameter ID
Parameter Name
Parameter Description
the MS. This level is reported in the system information. This parameter specifies the minimum receive level of an MS to access the BSS. For details. see GSM Rec. 05.08. The value of this parameter ranges from 0 to 63 (corresponding to -110 dBm to -47 dBm).
GUI Value Range: 0~63
Actual Value Range: 0~63
Unit: dB
Default Value: None
Recommended Value: 8 FRULDTX
FR Uplink DTX
Meaning: Whether the uplink DTX function is enabled for FR calls. For details, see GSM Rec. 05.08. Uplink DTX is not restricted by the MSC. If this parameter is set to May_Use, the MS can use DTX. If this parameter is set to Shall_Use or Shall_Not_Use, the MS cannot use DTX.
GUI Value Range: May_Use(May Use), Shall_Use(Shall Use),
Parameter ID
Parameter Name
Parameter Description
Shall_NOT_Use(Shall not Use)
Actual Value Range: May_Use, Shall_Use, Shall_NOT_Use
Unit: None
Default Value: None
Recommended Value: Shall_Use HRULDTX
HR Uplink DTX
Meaning: Whether the uplink DTX function is enabled for HR calls. For details, see GSM Rec. 05.08. Uplink DTX is not restricted by the MSC. If this parameter is set to May_Use, the MS can use DTX. If this parameter is set to Shall_Use or Shall_Not_Use, the MS cannot use DTX.
GUI Value Range: May_Use(May Use), Shall_Use(Shall Use), Shall_NOT_Use(Shall not Use)
Actual Value Range: May_Use, Shall_Use, Shall_NOT_Use
Parameter ID
Parameter Name
Parameter Description
Unit: None
Default Value: None
Recommended Value: Shall_Use CALLRESTABDIS
Call Reestablishmen Meaning: Whether to allow call ret Forbidden establishment. Burst interference or blind spots due to high buildings may lead to a radio link failure. If a call drop is caused by such a failure, the MS can start call reestablishment to resume the conversation.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: If this parameter is set to NO, the average call drop rate decreases. This setting is applicable in suburbs or urban areas with poor coverage. Call reestablishment, however, may take a
Parameter ID
Parameter Name
Parameter Description
long time. Therefore, the subscriber may hang up the phone before the call is reestablished. Generally, the recommended value is YES. IMMASSEN
TCH Immediate Assignment
Meaning: Whether to allow immediate TCH assignment. If this parameter is set to YES, the BSC can assign a TCH immediately when there is no available SDCCH for a channel request. If this parameter is set to NO, the BSC can assign only an SDCCH when processing a channel access request.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: NO DIRECTRYEN
Directed Retry Meaning: Whether to enable a directed retry. The directed retry is to hand over an MS to a neighboring cell in the same procedure as the handover. The directed retry is an emergency measure applicable to
Parameter ID
Parameter Name
Parameter Description
abnormal traffic peaks in some areas of a radio network. You should not use the directed retry as a major means of solving traffic congestion. If the directed retry always occurs in some areas of a network, consider adjusting the sector and TRX configuration and the network layout.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: YES UPPCEN
UL PC Allowed Meaning: Whether to allow MS power control
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Parameter ID
Parameter Name
Parameter Description
Unit: None
Default Value: None
Recommended Value: YES DNPCEN
DL PC Allowed Meaning: Whether to allow BTS power control
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: YES SDDYN
SDCCH Dynamic Allocation Allowed
Meaning: Whether to allow SDCCH dynamic allocation, that is, whether to allow dynamic conversion between TCHs and SDCCHs.
Parameter ID
Parameter Name
Parameter Description
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: YES LEVELRPT
Level Report Switch
Meaning: Whether to support the reporting of the main diversity level
GUI Value Range: NO(Not Support), YES(Support), NONE(Invalid)
Actual Value Range: NO, YES, NONE
Unit: None
Default Value: None
Parameter ID
Parameter Name
Parameter Description
Recommended Value: None DYNOpenTrxPower
Allow Dynamic Shutdown of Meaning: This parameter specifies whether TRX to allow the BSC6900 to enable the TRX Intelligent Shutdown feature on a cell.
GUI Value Range: NO(No), YES(Yes)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: YES BTSadjust
Adjust Voltage Meaning: This parameter specifies whether to enable the TRX Working Voltage Adjustment feature. When this parameter is set to YES, the BSC6900 supports the feature where the power amplifier can use different working voltages in different TRX modulation modes.
GUI Value Range: NO(No), YES(Yes)
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: YES GMSKDELAY
Diversity Transmitter GMSK Delay
Meaning: Delay of transmit diversity when GMSK is used. Generally, the parameter is applicable to general fading environments. In this case, the transmit diversity can obtain the gain of 3 dB to 5 dB. The fading degrees, however, vary with environments. For a fixed delay, different UEs may obtain different gains. In addition, a fixed delay may have negative impacts on some codes of the EDGE service. Therefore, the delay of transmit diversity must be configurable and can be set for GMSK and 8PSK respectively.
GUI Value Range: 4~32
Actual Value Range: 0.5~4, step: 1/8
Parameter ID
Parameter Name
Parameter Description
Unit: bit
Default Value: None
Recommended Value: 20 DIVERT8PSKDELAY
Diversity Transmitter 8PSK Delay
Meaning: Delay of transmit diversity when 8PSK is used. Generally, the parameter is applicable to general fading environments. The transmit diversity can generally bring a gain of 3 dB to 5 dB. The fading conditions vary with the MS location; therefore, MSs in a fixed time delay obtain different gains. In addition, the EDGE service coding may be adversely affected. Therefore, the time delay of transmit diversity must be configurable and can be separately set for GMSK and 8PSK. Only the doubletransceiver BTSs and the distributed BTSs can be configured with this parameter. For the BTSs of other types, this parameter is set to an invalid value 255.
GUI Value Range: 4~32
Actual Value Range: 0.5~4, step: 1/8
Unit: bit
Parameter ID
Parameter Name
Parameter Description
Default Value: None
Recommended Value: 4 ICBALLOW
ICB Allowed Meaning: This parameter is used to enable the Intelligent Combiner Bypass (ICB) function on the BCCH TRX of a cell. This parameter specifies whether to allow the cell to enable the ICB function. When this parameter is set to YES, the TCHs on the non-BCCH TRX are preferentially assigned. In this way, the largest possible number of idle TCHs is reserved on the BCCH TRX, and thus the BCCH TRX enters the ICB mode.
GUI Value Range: NO(NO), YES(YES), NULL(NULL)
Actual Value Range: NO, YES, NULL
Unit: None
Default Value: None
Recommended Value: NO
Parameter ID
Parameter Name
TIMESLOTVOLADJALLOW Voltage Adjust Based Timeslots Allowed
Parameter Description
Meaning: This parameter determines whether the dynamic voltage adjustment function is enabled on the basis of the number of timeslots. If this parameter is set to YES, the power consumption of base stations is reduced. This parameter maps the versions of base stations. If the parameter is set to NULL, base stations do not support this function.
GUI Value Range: NO(No), YES(Yes), NULL(Null)
Actual Value Range: NO, YES, NULL
Unit: None
Default Value: None
Recommended Value: NO DIVERT16QAMDELAY
Diversity Transmitter 16QAM Delay
Meaning: Delay of transmit diversity when 16QAM is used. Generally, the parameter is applicable to general fading environments. The transmit diversity can generally bring a gain of 3 dB to 5 dB. The fading conditions vary with the MS location; therefore, MSs in a fixed time delay obtain different gains. In addition, the EDGE service coding may be adversely affected. To avoid the
Parameter ID
Parameter Name
Parameter Description
preceding cases, the delay of transmit diversity must be configurable and can be set for GMSK and 16QAM respectively. Only the double-transceiver BTSs and the distributed BTSs can be configured with this parameter. For the BTSs of other types, this parameter is set to an invalid value 255.
GUI Value Range: 4~32
Actual Value Range: 0.5~4, step: 1/8
Unit: bit
Default Value: None
Recommended Value: 4 DIVERT32QAMDELAY
Diversity Transmitter 32QAM Delay
Meaning: Delay of transmit diversity when 32QAM is used. Generally, the parameter is applicable to general fading environments. The transmit diversity can generally bring a gain of 3 dB to 5 dB. The fading conditions vary with the MS location; therefore, MSs in a fixed time delay obtain different gains. In addition, the EDGE service coding may be adversely affected. To avoid the preceding cases, the delay of transmit diversity must be configurable and can be set for GMSK and 32QAM respectively.
Parameter ID
Parameter Name
Parameter Description
Only the double-transceiver BTSs and the distributed BTSs can be configured with this parameter. For the BTSs of other types, this parameter is set to an invalid value 255.
GUI Value Range: 4~32
Actual Value Range: 0.5~4, step: 1/8
Unit: bit
Default Value: None
Recommended Value: 4 POWERREDUCE16QAM
16QAM Transmitter Power Reduce Level
Meaning: Power attenuation level of timeslot 7 of the BCCH in 16QAM. The attenuation level ranges from 0 to 50, with the step of 0.2 dB. When the EDGE TRX sends signals in 16QAM, the transmit power must be lower than the mean power in GMSK.
GUI Value Range: 0~50
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: 0~10, step: 0.2
Unit: dB
Default Value: None
Recommended Value: 0 POWERREDUCE32QAM
32QAM Transmitter Power Reduce Level
Meaning: Power attenuation level of timeslot 7 of the BCCH in 32QAM. The attenuation level ranges from 0 to 50, with the step of 0.2 dB. When the EDGE TRX sends signals in 32QAM, the transmit power must be lower than the mean power in GMSK.
GUI Value Range: 0~50
Actual Value Range: 0~10, step: 0.2
Unit: dB
Default Value: None
Parameter ID
Parameter Name
Parameter Description
Recommended Value: 0 CELLSCENARIO
Cell Scenario Meaning: Information about the cell scenario. It needs to be sent to the BTS. Based on the information, the BTS optimizes the allocation of resources.
GUI Value Range: COMMON(COMMON), MULTIPATH(MULTIPATH), INDOOR(INDOOR), HIGHWAY(HIGHWAY)
Actual Value Range: COMMON, MULTIPATH, INDOOR, HIGHWAY
Unit: None
Default Value: None
Recommended Value: COMMON CELL8PSKPOWERLEVEL
Cell 8PSK Power Attenuation Grade
Meaning: Timeslot power attenuation level of the EDGE TRX in 8PSK. The attenuation level ranges from 0 to 50, each of which corresponds to an attenuation of 0.2 dB. When the EDGE TRX sends signals in 8PSK, the transmit power must be lower
Parameter ID
Parameter Name
Parameter Description
than the mean power in GMSK.
GUI Value Range: 0~50
Actual Value Range: 0~50
Unit: None
Default Value: None
Recommended Value: 0 FASTCALLTCHTHRESHOL D
Fast Call Setup TCH Usage Threshold
Meaning: After a channel request message is received, the type of the channel needs to be specified. In this case, if the threshold of the load on the TCH in the current cell is smaller than the Fast Call Setup TCH Usage Threshold and the request message is not issued during location update or paging, a TCH is preferentially assigned.
GUI Value Range: 0~100
Actual Value Range: 0~100
Parameter ID
Parameter Name
Parameter Description
Unit: per cent
Default Value: None
Recommended Value: 0 IMMASSCBB
Immediate Assignment Optimized
Meaning: The channel activation and immediate assignment messages are sent at the same time to accelerate the signaling processing, thus increasing the response speed of the network.
GUI Value Range: NO(NO), YES(YES)
Actual Value Range: NO, YES
Unit: None
Default Value: None
Recommended Value: NO NBAMRTFOSWITCH
TFO Switch Meaning: Whether to enable the Tandem Free Operation (TFO) function on the BTS
Parameter ID
Parameter Name
Parameter Description
through a CHANNEL ACTIVATION or MODE MODIFY message. This parameter specifies whether to enable the Tandem Free Operation (TFO) function. If the voice quality of an ongoing MS-to-MS call is bad, the TFO function can be enabled to improve end-to-end voice quality. The TFO function cannot be used to improve the voice quality of an MS-to-PSTN call.
GUI Value Range: DISABLE(Disable), ENABLE(Enable)
Actual Value Range: DISABLE, ENABLE
Unit: None
Default Value: None
Recommended Value: DISABLE RTPSWITCH
Measure Link Delay Switch
Meaning: Whether to measure the delay on the link between the BTSs that serve the calling MS and the called MS respectively
GUI Value Range: DISABLE(Disable), ENABLE(Enable)
Parameter ID
Parameter Name
Parameter Description
Actual Value Range: DISABLE, ENABLE
Unit: None
Default Value: None
Recommended Value: DISABLE
Example To set cell basic Parameters of a cell (Cell Index = 44, BFEDGEMTX=YES, LAYER=1), run the following command: SET GCELLBASICPARA: IDTYPE=BYID, CELLID=44, BFEDGEMTX=YES, LAYER=1;