PRACTICA CALIFICADA DOMICILIARIA DE DISEÑO EN ACERO CICLO 2017-1 SEGUNDA ETAPA
SECCIONES C1,C2,C3 CUMPLIMIENTO OBLIGATORIO INDICACIONES: DE CUMPLIMIENTO FECHA DE PRESENTACION: indicado en clase DESARROLLADO A MANO, EN PAPEL CUADRICULADO TAMAÑO OFICIO: CUADERNILLO, LAS PAGINAS DEBEN ESTAR ENUMERADAS. CADA PROBLEMA DEBE ESTAR CON SU RESPECTIVO ENUNCIADO, Y NUMERACION: NO ES NECASARIO FOLDER, NI GANCHOS, NI SUJETADORES (FASTENERS), NI CARATULA,
SOLO INDICAR APELLIDOS, NOMBRES Y SECCION
NO ES NECESARIO PONER PONER EL NOMBRE DEL DOCENTE.
Se evaluará el orden, detalle de los gráficos, EXCELENTE presentación, EXACTITUD EN LOS RESULTADOS
1. Seleccionar una viga de ASTM A992 en forma de W con un tramo sencillo de 40 pies. Las cargas de servicio son una carga muerta uniforme de de 0,05 kip / pie y dos cargas vivas concentradas PL = 18 kip iguales que que actúan en los puntos tercios tercios de la viga. La viga se apoya continuamente. También calcular la deformación
2. Verifique la resistencia resistencia a la flexión flexión disponible disponible de la viga W18 × 50, ASTM ASTM A992, apoyada en los extremos y en el punto central. Utilice las tablas Manual de AISC.
1
3. Encuentre los valores de Sx, Zx y del factor de forma respecto al eje x de las secciones mostradas a continuación . a)
b)
c)
d)
4. Usando las secciones dadas, todas de acero A992, y la teoría plástica, determine los valores de Pn y wn según se indica . a)
2
b)
c)
d)
5. Usando el método LRFD , seleccione las secciones más económicas,con Fy = 50 klb/plg 2 a menos que se indique otra cosa, y suponiendo soporte lateral continuo para los patines de compresión. Las cargas de servicio o de trabajo están dadas en cada caso, pero el peso de las vigas no se incluye. a)
b)
3
c)
6. Una viga de L =8 m empotrada en los extremos, bajo una carga Wu=60 kN/m (incluye peso propio), tiene soporte lateral a PLT Mn=Mp .La deflexión bajo carga viva del Servicio WL, debe ser menor a L/ 360. Hallar el perfil W de A36 que cumplas con las condiciones dadas
7. Usando acero de 50 klb/plg2 y ambos métodos LRFD y ASD, seleccione la sección más ligera disponible para la situación mostrada en la Figura . Se proporciona soporte solamente en los extremos y a la mitad del claro.
8. Determine el esfuerzo de diseño a flexión LRFD para una sección W12 x 65 de 50 klb/plg2 que tiene soporte lateral continuo.
9. Diseñe la viga con el perfil W más ligero de acero de 50 klb/plg2 para soportar las cargas mostradas en la Figura. Desprecie el peso propio de la viga. La viga tiene soporte lateral continuo entre A y B, pero no lo tiene entre B y C.Determine Cb.
4
10 Se usa una viga W24 x 104 para soportar las cargas mostradas en la Figura P9-28.Se proporciona soporte lateral del patín de compresión solamente en los extremos.Determine Cb. Si Fy = 50 klb/plg2, determine si la W24 es adecuada para sustentar estas cargas.
11
5
12 Find the lightest W section of A36 steel. Lateral braces are provided only at the supports and at midspan. The factored beam weight is accounted for in the concentrated load. There is no limiting deflection criterion to be satisfied
.
13. Select the most economical rolled shape for a 27-ft simply supported floor beam . The upper (compression) flange of the beam is adequately welded to the floor deck at 1ft O-in intervals. Dead load supported by the beam (including its own weight) is 1.3 kips per linear foot ; live load is 2.6 kips per linear foot. Steel is A36. Assume:
(a) There is no member depth limitation . (b) The deepest (architecturally allowable) member is a W21. (c)
The deepest desired member is a W18.
14. For the cross section , with four 1 ½ in-diameter holes for bolts (two holes per flange, as shown), determine the design values of
(a) Sx, the elastic section modulus for major axis bending. (b) Zx, the plastic section modulus for major-axis bending.
15.
6
16.
17.
Pu =345 kips
18. Para la junta traslapada mostrada en la Figura 12.9, las cargas axiales de servicio son PD = 27.5 klb y PL = 40 klb. Determine el número de tornillos de fricción A325 de 1 plg para agujeros de tamaño estándar que se necesitan para el estado límite de deslizamiento si la superficie de contacto es de Clase A. La distancia al borde es de 1.75 plg, y la separación centro a centro de los tornillos es de 3 plg. Fy = 50 klb/plg2. Fu = 65 klb/plg2.
19. Determine la resistencia de diseño por tensión según el método LRFD para el miembro mostrado, suponiendo una conexión tipo aplastamiento.
7
a) Tornillos A325 de 3/4 plg , roscas excluidas del plano de corte. b) Tornillos A325 de 1 plg, roscas excluidas del plano de corte. c) Tornillos A490 de 1 plg, roscas no excluidas del plano de corte.
20. Cuántos tornillos se requieren para el método LRFD para la conexión tipo aplastamiento mostrada, si PD = 50 klb y PL = 100 klb?
a) Para tornillos A325 de 3/4 plg , roscas excluidas del plano de corte. b) Si Fy = 50 klb/plg2, Fu = 70 klb/plg2, tornillos A325 de 3 4 plg, roscas excluidas del plano de corte. c) Tornillos A490 de 1 plg, roscas no excluidas del plano de corte.
21. ¿Cuál es la resistencia de diseño de la conexión mostrada en la Figura 14.12 si las placas consisten en acero A572 Grado 50 (Fu = 65 klb/plg2)? Se usaron electrodos E70, y las soldaduras de filete de 7/16 plg se hicieron con el proceso SMAW.
22 a) Usando solamente el método LRFD, determine el tamaño de soldadura de filete que se requiere para la conexión mostrada en la siguiente figura. Electrodo E70. a) Use el método elástico. b) Use las tablas del AISC y el método de resistencia última.
8
b) Suponiendo que va a usarse el método LRFD, determine el tamaño de soldadura de filete que se requiere para la conexión mostrada en la siguiente figura. Use electrodos E70 y el método elástico.
9