OpenPlant Isometric Manager V8i
Bentley Institute Course Guide
TRN016900-1/0001
Trademark Notice Bentley and the "B" Bentley logo are either registered or unregistered trademarks or service marks of Bentley Systems, Incorporated. All other marks are the property of their respective owners. AccuDraw, MDL, MicroStation, and SmartLine are registered trademarks; PopSet and Raster Manager are trademarks. AutoCAD is a registered trademark of Autodesk, Inc.
Copyright Notice Copyright ©2011, Bentley Systems, Incorporated. All Rights Reserved.
OpenPlant Isometric Manager
2
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Table of Contents
Course Overview ____________________________________ 7 Course Description ___________________ _____________________________ _________________7 _______7 Target Audience_____________ Audience______________________ ___________________ _________________7 _______7 Prerequisites __________________ ____________________________ ___________________ _____________7 ____7 Course Objectives ___________________ ____________________________ __________________8 _________8 Modules Included ___________________ ____________________________ __________________8 _________8 System Requirements ___________________ _____________________________ _______________8 _____8 Software Requirements________________ Requirements__________________________ _________________9 _______9
Isometric Style Setup ________________________________ 11 Module Overview ___________________ ____________________________ __________________11 _________11 Module Prerequisites ___________________ ____________________________ _______________11 ______11 Module Objectives______________ Objectives_______________________ ___________________ ______________11 ____11 Isometric Manager Styles ___________________ _____________________________ ____________12 __12 Module Review ___________________ _____________________________ ___________________ __________1 _18 8 Questions ___________________ ____________________________ ___________________ ____________18 __18 Answers__________________________________________18
Design State Mapping and Revision Control ______________ 19 Module Overview ___________________ ____________________________ __________________19 _________19 Module Prerequisites ___________________ ____________________________ _______________19 ______19 Module Objectives______________ Objectives_______________________ ___________________ ______________19 ____19 Design State Mapping Mapping ___________________ ____________________________ _______________20 ______20 Revision control ___________________ ____________________________ ___________________ ___________22 _22 Module Review ___________________ _____________________________ ___________________ __________2 _28 8 Questions ___________________ ____________________________ ___________________ ____________28 __28 Answers__________________________________________28
Drawing Attributes __________________________________ _______ ___________________________ 29 Module Overview ___________________ ____________________________ __________________29 _________29 Module Prerequisites ___________________ ____________________________ _______________29 ______29 Module Objectives______________ Objectives_______________________ ___________________ ______________29 ____29 Customization of drawing attributes for additional pipeline information ___________________ ____________________________ ___________________ ______________30 ____30 Module Review ___________________ _____________________________ ___________________ __________3 _37 7
Jul-11
3
Copyright © 2011 Bentley Systems, Incorporated
Table of Contents
Table of Contents
Questions ___________________ ____________________________ ___________________ ____________37 __37 Answers__________________________________________37
Bill of Material ______________________________________ 39 Module Overview ___________________ ____________________________ __________________39 _________39 Module Prerequisites ___________________ ____________________________ _______________39 ______39 Module Objectives______________ Objectives_______________________ ___________________ ______________39 ____39 Project driven drawing drawing output and Bill of Material Definitions __40 Module Review ___________________ _____________________________ ___________________ __________4 _44 4 Questions ___________________ ____________________________ ___________________ ____________44 __44 Answers__________________________________________44
Isometric Symbols Customization ______________________ 45 Module Overview ___________________ ____________________________ __________________45 _________45 Module Prerequisites ___________________ ____________________________ _______________45 ______45 Module Objectives______________ Objectives_______________________ ___________________ ______________45 ____45 Customization of isometric symbols symbols ___________________ _______________________46 ____46 Module Review ___________________ _____________________________ ___________________ __________5 _54 4 Questions ___________________ ____________________________ ___________________ ____________54 __54 Answers__________________________________________54
ProjectWise Connection ______________________________ 55 Module Overview ___________________ ____________________________ __________________55 _________55 Module Prerequisites ___________________ ____________________________ _______________55 ______55 Module Objectives______________ Objectives_______________________ ___________________ ______________55 ____55 ProjectWise Settings for Isometric Drawings ________________56 ________________56 Module Review ___________________ _____________________________ ___________________ __________6 _63 3 Questions ___________________ ____________________________ ___________________ ____________63 __63 Answers__________________________________________63
Management of PCF files _____________________________ 65 Module Overview ___________________ ____________________________ __________________65 _________65 Module Prerequisites ___________________ ____________________________ _______________65 ______65 Module Objectives______________ Objectives_______________________ ___________________ ______________65 ____65 Generate PCF files for passing data data to legacy systems _________66 Module Review ___________________ _____________________________ ___________________ __________7 _71 1 Questions ___________________ ____________________________ ___________________ ____________71 __71 Answers__________________________________________71
Course Summary ____________________________________ 73 Course Summary __________________ ____________________________ ___________________ __________ _ 73 Course Review ___________________ ____________________________ ___________________ ____________74 __74 Questions ___________________ ____________________________ ___________________ ____________74 __74 Answers__________________________________________75
Jul-11
4
Copyright © 2011 Bentley Systems, Incorporated
Table of Contents
Table of Contents
Appendix A ________________________________________ 77 rep_sortgroups.txt_____________________________________77
Appendix B ________________________________________ 81 report.def____________________________________________81
Jul-11
5
Copyright © 2011 Bentley Systems, Incorporated
Table of Contents
Table of Contents
Table of Contents
6
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Course Overview Course Description This course is designed to instruct the project administrator how to customize Isometric Drawings to meet corporate standards. You will be instructed on how to setup i sometrics styles, how to customize drawing attributes for additional pipeline information. You will learn how to configure Bill of Material output and layout. You will also create custom isometric symbols. You will be instructed how to generate PCF files for passing data to legacy systems and how to set connection to ProjectWise for deliverables Management.
Target Audience This course is recommended for the following audience(s): •
Engineers, Designers and Drafters responsible for customizing Isometric Manager software to fit their corporate needs.
Prerequisites
Jul-11
•
Students taking this course should have a working knowledge of MicroStation and 3D modeling concepts.
•
Students should have completed the OpenPlant Modeler User training.
•
Students should have understanding of OpenPlant Modeler, of OpenPlant projects and of OpenPlant Model Server.
•
Students should have working knowledge of ProjectWise Explorer.
7 Copyright © 2011 Bentley Systems, Incorporated
Course Overview
Course Objectives
Course Objectives After completing this course, you will be able to: •
Use the Isometric Configuration tool.
•
Customize drawing attributes for additional pipeline information.
•
Setup drawing layout and Bill of Material definitions.
•
Customize existing and create new custom isometric symbols.
•
Set Isometric Revision Format.
•
Set connection to ProjectWise for deliverables Management.
•
Allow PCF File Generation.
Modules Included The following modules are included in this course: •
Isometric Style Setup
•
Design State Mapping and Revisions control
•
Drawing Attributes
•
Bill of Material
•
Isometric Symbols Customization
•
ProjectWise Connection
•
Management of PCF files
System Requirements You must have a CD drive or Internet access for product installation. The following prerequisites are required to run the OpenPlant Isometric Manager(SELECTseries3): Processor: Intel Pentium 4 processor or AMD Athlon, 3.0 GHz or greater, or I ntel or AMD Dual Core Processor, 2.0 GHZ or greater
Course Overview
8
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Software Requirements
Operating System: Windows 7, Windows 7 x64, Windows Vista, Windows Vista x64, Windows XP Professional (SP2 or later) Windows XP Professional x64, Windows XP Home Edition (SP2 or later), Windows XP Tablet PC Edition, Windows 2000 Professional (SP3 or later), Windows 2000 Server, Windows Server 2003 (SP1 or later), Windows Server 2003 x64, Windows Server 2008, Windows Server 2008 x64. Microsoft Office: Professional Edition 2000 (SR1a), XP, 2003 or 2007. Memory: 2GB minimum recommended (More memory almost always improves performance, particularly when working with larger models.). Hard Disk: Requires 30 MB minimum free hard disk space in addition to the OpenPlant Modeler V8i requirement of 400 MB minimum free hard disk space. Input Device: Any industry-standard input device supported by Windows. Output Device: Any industry-standard output device supported by Windows.
Software Requirements ProjectWise Explorer V8i (SELECTseries 2), Bentley OpenPlant Modeler V8i (SELECTseries 3), Network access to OpenPlant ModelServer V8 i .
Jul-11
9
Copyright © 2011 Bentley Systems, Incorporated
Course Overview
Software Requirements
Course Overview
10
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Isometric Style Setup Module Overview In order to control generation of different types of Isometric Drawings, an administrator will need to define new and modify existing styles and their base default values used for an Isometric Drawing generation.
Module Prerequisites •
Students should have completed the OpenPlant Modeler User course.
Module Objectives After completing this module, you will be able to:
Jul-11
•
Use Isometric Configuration tool to specify basic parameters of Isometric Drawings.
•
Create a new Isometric Style.
•
Set Design State mapping.
11 Copyright © 2011 Bentley Systems, Incorporated
Isometric Style Setup
Isometric Manager Styles
Isometric Manager Styles Isometric Drawings generated in different project stages have to meet different requirements. We will address the different isometric styles. The Isometric Configuration tool enables you to set a Default Isometric Style for the whole project.
If different Isometric Styles are to be used for Isometric Drawing generation, Design States have to be mapped to these styles.
Isometric Style Setup
12
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Isometric Manager Styles
You can define as many isometric styles as required. Isometric Style features can be set by: •
Using the Isometric Configuration tool.
•
Customizing configuration text files located in the project Workspace directory.
Isometric Style setting using the Isometric Configuration tool There are three dialogs available to change the Isometric Style features. They are the Isometric Style dialog, the Isometric Drawing Attributes dialog and the Label dialog. The Isometric Style dialog enables you to specify basic parameters.
•
Graphical Configuration tool: This field is used to start an OP Modeler session and to customize the isoseed file used for creating Isometric Drawings.
•
Completed Isometric Design State: This parameter specifies which design state to set piping components when an Isometric Drawing is created and placed into ProjectWise.
The Isometric Drawing Attributes dialog is described in more detail in the module Drawing Attributes.
Jul-11
13
Copyright © 2011 Bentley Systems, Incorporated
Isometric Style Setup
Isometric Manager Styles
The Label dialog specifies the labels to be used on an Isometric Drawing.
Isometric Style Setting using Configuration Text Files For example, for the As-Built style the following configuration text files located in: C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\AsBuilt\Config •
isoextract.dat: no longer needed.
•
node2da.txt: mapping of textnode numbers to named drawing attributes.
•
operator.tbl: mapping of operator names (as supplied by OPM) to symbols to be used in isometrics.
•
pcf.ini: configuration for IsoExtractor PCF writer.
•
rep_sortgroups.txt: definition of sort groups for Bill of Material.
•
report.def : definitions for all reports produced by IsoExtractor.
•
scaler.ini: scale settings.
•
style.cfg: IsoExtractor configuration file.
•
symbolsizes.def : definitions of the basic scaler classes.
Isometric Style Setup
14
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Isometric Manager Styles
All text files include a short description of the purpose and their content is well commented. The file isoseed.dgn located in the same directory is a seed used by Iso extractor when an iso drawing is created.
Exercise: Create a new Isometric Style The goal of this exercise is to create a new Isometric Style called Training based on an existing Isometric Style As-Built. It will be set as the default for Iso Sheets in the Design State of In Checking.
Jul-11
1
Select Tools > Configuration.
2
Right-click on Isometric Style.
3
Click Add New Style.
4
Select As-Built from the Select Base Style list.
5
Type Training in the Name of Style field.
6
Click OK.
15
Copyright © 2011 Bentley Systems, Incorporated
Isometric Style Setup
Isometric Manager Styles
The following message appears:
7
Navigate to the C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics directory.
8
Open the file StyleListing.cfg in Notepad.
9
Add the following text in the List of Styles section.
10 Save the file. 11 Exit the Isometric Manager and start it again. 12 Select Tools > Configuration or click the Configuration icon. 13 Select Model Server Design State Mapping > InChecking . 14 Select Training from the Isometric Style list.
Isometric Style Setup
16
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Isometric Manager Styles
Note: To remove an existing style you can select it in the Isometric Style list,
right-click and select Remove.
Note: If a style is used (for example assigned to a Design State) it can't be
removed.
Jul-11
17
Copyright © 2011 Bentley Systems, Incorporated
Isometric Style Setup
Module Review
Module Review Now that you have completed this module, let’s measure what you have learned.
Questions 1
Why we are using Model Server Design State Mapping?
2
What is specified by the Completed Isometric Design State parameter?
3
True/False: Using Isometric the Isometric Configuration tool is the only way how to customize Isometric Styles.
Answers
Isometric Style Setup
1
Model Server Design State Mapping enables to use different Isometric Styles for processing of Iso Sheets with respect to their Design States.
2
Completed Isometric Design State parameter specifies to which design state to set piping components when an Isometric Drawing is created and put into ProjectWise.
3
False: Isometric Style features can be set by using the Isometric Configuration tool or by customizing configuration text files located in the project Workspace directory.
18
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Design State Mapping and Revision Control Module Overview Isometric Manager enables to map single Design States to specific Isometric Styles. Administrator will need to modify this mapping and to customize it to meet company requirements.
Module Prerequisites •
Students should have completed the OpenPlant Modeler User course.
•
Students should have understanding of OpenPlant Modeler.
Module Objectives After completing this module, you will be able to:
Jul-11
•
Map Design States to Isometric Styles.
•
Set Isometric Revision format and other Design State based properties.
19
Design State Mapping and Revision Control
Copyright © 2011 Bentley Systems, Incorporated
Design State Mapping
Design State Mapping Isometric Manager enables to set mapping between Design States and Isometric Styles. Note: This module explains Model Server Design State Mapping but exactly the same procedures can be applied for i-model Design State Mapping .
Exercise 1: Isometric Style setting. The target of this exercise is to map Design State InDesign to the Isometric Style IFC. 1
Select Tools > Configuration or click the Configuration icon.
2
Expand Model Server Design State Mapping.
3
Select InDesign.
4
Select IFC from the Isometric Style list.
5
Click Save.
Design State Mapping and Revision Control
20
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Design State Mapping
The Isometric Style assignment is applied.
Note: If you do not click Save and click in the left part of the Isometric Configuration dialog a warning message appears. Click Yes to confirm
changes.
6
Jul-11
Close the Isometric Configuration dialog.
21 Design State Mapping and Revision Control Copyright © 2011 Bentley Systems, Incorporated
Revision control
Revision control Revisions are assigned to Isometric Drawings based on Isometric Revision setting specified for each Design State. If no specific Isometric Revi sion format is specified for a used Design State, the system uses the Isometric Revision format set for a Project. Isometric Revision formats set for a Design Stage has a priority. A revision is set for an iso drawing during its creation. The system checks ProjectWise for the last revision of the generated Isometric Drawing and assigns the next available revision.
Exercise 1: Isometric Revision setting The goal of this exercise is to set a format of Revision for IFC Isometric Style to R1, R2, etc. 1
Select Tools > Configuration or click the Configuration icon.
2
Expand Model Server Design State Mapping.
3
Select InDesign.
4
Select IFC from the Isometric Style list.
5
Select the Isometric Revision field.
6
Click Browse. The Revision Settings dialog opens.
7
Set Customized in the Revision Format group box.
Design State Mapping and Revision Control
22
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Revision control
8
Set the Prefix , Separator and Postfix fields as shown below:
9
Click Test.
10 Click Next. The Customized Revision is set to R0.
11 Click Next. The Customized Revision is set to R1. 12 Set Set as starting value. 13 Click OK.
14 Click OK. The Customized Revision dialog closes. 15 Click OK. The Revision Settings dialog closes.
Jul-11
23 Design State Mapping and Revision Control Copyright © 2011 Bentley Systems, Incorporated
Revision control
16 Click Save. The new Isometric Revision setting is applied.
17 Close the Isometric Configuration dialog.
Exercise 2: Isometric Name setting An Isometric Name is the name which is assigned to an automatically generated Isometric Drawing. The goal of this exercise is to set the Isometric Name to
– .
1
Select Tools > Configuration or click the Configuration icon.
2
Expand Model Server Design State Mapping.
3
Select InDesign.
4
Select the Isometric Name field.
Design State Mapping and Revision Control
24
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Revision control
Jul-11
5
Browse. Click Browse.
6
LINENUMBER from the Property field Select LINENUMBER from field list.
7
Add. Click Add.
8
Type - in the Text field. field.
9
DESIGN_STATE from the Property field Select DESIGN_STATE from field list.
25 Design State Mapping and Revision Control Copyright © 2011 Bentley Systems, Incorporated
Revision control
Add. 10 Clic lick Add.
OK. 11 Clic lick OK. To close the Isometric Name Expression Editor dialog. dialog.
Save. 12 Clic lick Save. To apply the new Isometric Name setting. 13 Clos Close e the the Isometric Configuration dialog.
Exercise 3: Design States Color setting Design States Color specifies specifies a color used to display Iso Sheet in the I sometric Manager window. It helps to distinguish groups of iso sheets in the same Design State. The goal of this exercise is to display Iso Sheets assigned to the Design State InDesign in the Red color.
1
Configuration or click the Configuration icon. Configuration icon. Select Tools > Configuration or
2
Expand Model Server Design State Mapping. Mapping .
3
InDesign. Select InDesign.
Design State Mapping and Revision Control
26
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Revision control
4
Color field. Select th the Design States Color field.
5
Browse. Click Browse.
6
Red color. Select Red color.
7
OK. Click OK.
8
Save. Click Save. The new Design States Color setting is applied.
9
Click Close. Close. The Isometric Configuration dialog closes.
Jul-11
27 Design State Mapping and Revision Control Copyright © 2011 Bentley Systems, Incorporated
Module Review
Module Review Now that you have completed this module, let’s measure what you have learned.
Questions 1
True/False: True/False: Assignment of Design States to Isometric Styles is managed by the ProjectWise Administrator application.
2
True/False: True/False: The Revision format of Isometric Drawings can be Alphabetic or Numerical.
3
True/False: True/False: Design States Color enables to distinguish if a Design State of an Isometric Drawing has changed or not.
Answers 1
False: False: Mapping Mapping between between Design Design States States and and Isometric Isometric Styles Styles is manag managed ed by the Configuration tool which is a part of the I sometric Manager interface.
2
False: False: The Revision Revision format format of Isometric Isometric Drawings Drawings can be Alphab Alphabetic, etic, Numerical or Customized.
3
False: False: Design Design States States Color Color specifies specifies a color color used to to display display Iso Sheets Sheets in in the Isometric Manager window. It helps to distinguish groups of iso sheets in the same Design State.
Design State Mapping and Revision Control
28
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Drawing Attributes Module Overview Drawing Attributes are used on Isometric drawings to give more information about the pipeline from which the Isometric was extracted. An administrator will need to modify the attributes to be used on the Isometric drawings and where they should be placed based on the company requirements.
Module Prerequisites •
Students should have completed the OpenPlant Modeler User course.
•
Students should have a working knowledge of MicroStation.
•
Students should have understanding of OpenPlant Modeler.
Module Objectives After completing this module, you will be able to:
Jul-11
•
Modify attributes that will be placed on Isometric drawings.
•
Modify a seed file to customize the position of Drawing Attributes.
29 Copyright © 2011 Bentley Systems, Incorporated
Drawing Attributes
Customization of drawing attributes for additional pipeline information
Customization of drawing attributes for additional pipeline information Let us suppose you need to add the attribute INTERNAL_PRESSURE to attributes displayed on an Isometric drawing generated using Isometric Style IFC. The whole procedure can be divided into three steps: Customization of selected attributes. Customization of the seed file isoseed.dgn. Customization of the mapping file node2da.txt.
Exercise 1: Customization of selected attributes 1
Select Tools > Configuration or click the Configuration icon.
2
Select Isometric Style > IFC > Drawing Attributes in the Isometric Configuration dialog. The table which appears in the right window shows the pre-defined drawing attributes provided by the system for the Isometric Style IFC.
By default there are available 32 attributes for each Isometric Style to be used on an Isometric Drawing. Each so called Drawing Attribute Collection is specified by the NAME and by the VALUE . Attributes can be added or deleted from the default list.
Drawing Attributes
30
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Customization of drawing attributes for additional pipeline information
To delete an attribute select it, right-click and select Delete Attribute .
As the INTERNAL_PRESSURE is not currently among displayed attributes we have to add it. 3
Navigate to the top of the Isometric Drawing Attributes list to the Drawing Attribute Collection field, right-click and select Add Attribute.
A new empty section is created to define a new attribute.
Jul-11
4
Type Internal_Pressure in the NAME field.
5
Click Browse in the VALUE field.
6
Set Use ECProperty.
7
Set Use Parent Class.
8
Select PIPING_NETWORK_SYSTEM in the Use Parent Class group box.
31
Copyright © 2011 Bentley Systems, Incorporated
Drawing Attributes
Customization of drawing attributes for additional pipeline information
9
Select INTERNAL_PRESSURE in the Property field.
10 Click OK.
11 Click SAVE.
Drawing Attributes
32
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Customization of drawing attributes for additional pipeline information
Note: There are another 2 options to specify a Value of a Drawing Attribute:
•
Use Expressions: This option allows you to define an EC property for the Iso_Sheet class to be displayed as the value for the drawing attribute.
•
Using ECProperty: The option is related to the ISO_SHEET class (and not to a parent class as used above in step 7). When used, this option enables you to select a property from the ISO_SHEET Property list to be displayed in the Value field.
Exercise 2: Customization of the seed file isoseed.dgn We defined a new Drawing Attribute in the last exercise, as the next step it is necessary to set the location of the Drawing Attribute on Isometric drawing. 1
Jul-11
Select Isometric Style > IFC.
33
Copyright © 2011 Bentley Systems, Incorporated
Drawing Attributes
Customization of drawing attributes for additional pipeline information
2
Click Browse in the Graphical Configuration tool field.
Bentley OpenPlant Modeler session starts and the file isoseed.dgn located in the project directory C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\I FC\Config is opened.
Drawing Attributes
3
Press CTRL + B or navigate to View Attributes and switch on Text Nodes.
4
Navigate to the bottom of the drawing to see currently assigned Text Nodes .
34
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Customization of drawing attributes for additional pipeline information
5
Using MicroStation tools, extend the attribute field as specified below:
6
Select by window Des temp and Text Node 25 and copy these texts to the left:
The Text Node number was automatically updated to the first next available number 65. Note: If you want a specific node number you can do the following: suppose
you want node 24. Before doing the copy enter the key-in command: NN=24
Jul-11
7
Replace Des temp with Int press.
8
Exit isoseed.dgn.
35
Copyright © 2011 Bentley Systems, Incorporated
Drawing Attributes
Customization of drawing attributes for additional pipeline information
Exercise 3: Customization of the mapping file node2da.txt 1
Navigate to C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\I FC\Config.
2
Open the file node2da.txt.
This file maps a text node numbers to named Drawing Attributes. Each line specifies one mapping. 3
Add a new line at the end of this text file: 65, Internal_Pressure 65 is the number of the Text Node inserted in the isoseed.dgn customization and the text string Internal_Pressure has to correspond to the text specified in the Drawing Attribute definition.
4
Drawing Attributes
Save and close the file node2da.txt.
36
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Module Review
Module Review Now that you have completed this module, let’s measure what you have learned.
Questions 1
True/False: Drawing Attributes are defined once for the whole project.
2
True/False: The number of Drawing Attributes is limited to 32.
3
True/False: All Drawing Attributes defined in Isometric Drawing Attributes list are automatically placed in a generated Isometric drawing.
Answers
Jul-11
1
False: Drawing Attributes are defined for each Isometric Style separately.
2
False: The number of Drawing Attributes is not limited to 32. Another Drawing Attributes can be add by the Add Attribute function.
3
False: User can decide which Drawing Attributes will be used on an automatically generated Isometric Drawing. Customization is done using two files: isoseed.dgn and node2da.txt.
37
Copyright © 2011 Bentley Systems, Incorporated
Drawing Attributes
Module Review
Drawing Attributes
38
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Bill of Material Module Overview A Bill of Material is automatically generated during the Isometric extraction process. An administrator will need to modify which properties should be included in a Bill of Material and to customize their layout on an Isometric drawing based on the company requirements.
Module Prerequisites •
Students should have completed the OpenPlant Modeler User course.
•
Students should have a working knowledge of MicroStation.
•
Students should have understanding of OpenPlant Modeler.
Module Objectives After completing this module, you will be able to:
Jul-11
•
Modify a report definition file.
•
Modify a seed file to customize the Bill of Material layout.
39 Copyright © 2011 Bentley Systems, Incorporated
Bill of Material
Project driven drawing output and Bill of Material Definitions
Project driven drawing output and Bill of Material Definitions Isometric Extractor reports – Bills of Material (BOM) - are generic reports that operate on component properties and are an integral part of each Isometric drawing. This BOMs can contain any database information connected with a piping component existing on an Isometric drawing. Generated reports are plain text files that can be attached to a text node in an Isometric drawing. A BOM is defined for each Isometric Style separately. See Appendix 1 for full description of the Report.def file. The file is very well commented.
Exercise 1: Customization of the file Report.def The goal of this exercise is to include the property MATERIAL in a BOM generated on your Isometric Drawings defined by the Isometric Style IFC. 1
Navigate to C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\I FC\Config.
2
Open Report.def with a text editor.
3
Navigate to the section REPORT = SHP, which writes shop material to a report Note: Column definition has the following syntax. : COLUMN
= : :
Where specifies the width of the column in character positions is a combination of: L
left aligned
R
right aligned
C
centered
W wrap, a new line will be added if the length of the expression exceeds the width of the report is an expression for the content of the report column. Any component attribute or string can be used. Example: IE_DESCRIPT + UUID + "and a string" would concatenate the atributes IE_DESCRIPT and UUID and the string "and a string"
Bill of Material
40
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Project driven drawing output and Bill of Material Definitions
4
Change the line COLUMN = 19: R : QUANTITY
to COLUMN = 9: R : QUANTITY
5
Add a new line after just edited line COLUMN = 10: L : STOCK_NUMBER
6
Repeat steps 4 and 5 in the section REPORT = FLD which writes field material to a report.
7
Close Report.def . Changes done in the Report.def file must be followed by changes in a seed file used for Isometric Drawing generation. This will be done in the next exercise.
Exercise 2: Configure Bill of Material layout When a user customizes the Report.def file it is also necessary to make corresponding changes in the file Isoseed.dgn, which is a seed file used by Isometric Manager to create Isometric drawings. Mostly it means to change a heading of the Bill of Materials. The goal of this exercise is to customize a heading of a Bill of Material to include the property STOCK NUMBER added to the BOM definition in the previous exercise. 1
Select Tools > Configuration or click the Configuration icon.
2
Select Isometric Style > IFC.
3
Click Browse in the Graphical Configuration tool field.
Bentley OpenPlant Modeler session starts and the file isoseed.dgn located in the project directory C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\I FC\Config is opened.
Jul-11
41
Copyright © 2011 Bentley Systems, Incorporated
Bill of Material
Project driven drawing output and Bill of Material Definitions
4
Navigate to the upper part of the BOM heading.
5
Double-click on Quantity and edit it to Quant.
6
Right-click on Quant and select Move.
7
Move text 7.4 mm to the left.
8
Right-click on Quant and select Copy.
9
Copy text 14 mm to the right.
10 Double-click the copied Quant text and edit it to Stock N.
11 Move the cursor over the line between Material and Size1, right-click and select Copy. 12 Copy this line 15 mm to the left.
13 Exit isoseed.dgn. 14 Generate an Isometric Drawing to see changes have been applied.
Bill of Material
42
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Project driven drawing output and Bill of Material Definitions
Note: At least one of the piping components from which Isometric drawing will be generated has to have a Stock Number property assigned.
Jul-11
43
Copyright © 2011 Bentley Systems, Incorporated
Bill of Material
Module Review
Module Review Now that you have completed this module, let’s measure what you have learned.
Questions 15 True/False: Customization of properties to be included in a Bill of Material can be done in the file style.cfg. 16 True/False: A layout of the Shop section and a layout of the Field section of Bill of Material are defined separately.
Answers
Bill of Material
1
False: Customization of properties to be included in a Bill of Material can be done in the file report.def.
2
True: The section REPORT = SHP of the report.def file writes Shop material to a report and the section REPORT = FLD writes Field material to a report.
44
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Isometric Symbols Customization Module Overview Isometric symbols used on Isometric Drawings are stored in cell l ibraries. Based on company requirements an Administrator will need to modify existing symbols or to create completely new symbols.
Module Prerequisites •
Students should have completed the OpenPlant Modeler User course.
•
Students should have a working knowledge of MicroStation.
•
Students should have understanding of OpenPlant Modeler.
Module Objectives After completing this module, you will be able to:
Jul-11
•
Change a shape of an isometric symbol.
•
Create a new isometric symbol to be used on Isometric Drawings.
45 Copyright © 2011 Bentley Systems, Incorporated
Isometric Symbols Customization
Customization of isometric symbols
Customization of isometric symbols Isometric symbols are stored in cell libraries. Isometric Manager enables to define a set of isometric symbols independently for each Isometric Style. For example, libraries used for the Isometric Style I FC are located in C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\IFC\Cell\ . Assignment of OpenPlant Components to names of iso symbols used by Isometric Manager is done in Openplant_3d_supplemental_isometrics_isoextractor.01.01.ecschema.xml located in C:\ProgramData\Bentley\OpenPlantModeler V8i \WorkSpace\Projects\OPModeler_Metric\DataSet\Schemas.
Exercise 1: Change a shape of the flanged Gate Valve Iso symbol used for the Isometric Style IFC The goal of this exercise is to change an existing symbol for gate valve
to
Isometric Symbols Customization
46
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Customization of isometric symbols
Jul-11
1
Select Tools > Configuration or click the Configuration icon.
2
Click Browse in the Graphical Configuration tool field.
3
When OpenPlant Modeler starts, select File > Open.
4
Browse to C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\I FC\Cell, select isocomp.cel.
5
Click Open.
6
Navigate to Models and select GATFL.
47
Copyright © 2011 Bentley Systems, Incorporated
Isometric Symbols Customization
Customization of isometric symbols
A model of GATFL opens.
7
Select Place Circle from the Drawing toolbar.
8
When prompted Place Circle by Center > Identify Center Point click the center of the Gate Valve using Intersect Snap and specify diameter as shown below.
9
Click the Element Selection tool. The Place Circle command is closed.
10 Exit OpenPlant Modeler. 11 Click Close. The Isometric Configuration dialog closes.
Isometric Symbols Customization
48
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Customization of isometric symbols
12 Generate an Isometric drawing containing flanged gate valve to see your customized symbol.
Exercise 2: Create a new Iso symbol used for the Isometric Style IFC. The goal of this exercise is to create a new iso symbol of a flanged Gate Valve. 1
Select Tools > Configuration or click the Configuration icon.
2
Click Browse in the Graphical Configuration tool field.
3
When OpenPlant Modeler starts, select IsoExtractor > Cell Creation Tool .
4
Click the Open Template File in the Create Cell toolbar.
Note: OpenPlant Isometric Manager offers a set of iso symbol templates
which were used to create an existing cell library and can be also used to define new symbols to be placed on Isometric drawings. These templates are located in C:\ProgramData\Bentley\OpenPlantIsometricsManagerV8i\WorkSpace \OPIM\cellTemplates. 5
Jul-11
Create a copy of valves.dgn to keep the original file untouched.
49
Copyright © 2011 Bentley Systems, Incorporated
Isometric Symbols Customization
Customization of isometric symbols
6
Select the copy and click Open.
7
Navigate to Gate Valve symbols.
8
Zoom in to the flanged Gate valve symbol.
9
Select Place Circle from the Drawing toolbar.
Isometric Symbols Customization
50
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Customization of isometric symbols
10 When prompted Place Circle by Center > Identify Center Point click the center of the Gate Valve using Intersect Snap and specify diameter as shown below.
11 Click the Element Selection tool. The Place Circle command is closed. 12 To distinguish the new symbol from a symbol customized previously in the cell library, select the new circle and change the weight of the active l ine to 4.
13 Select Tasks > Place Fence.
Jul-11
51
Copyright © 2011 Bentley Systems, Incorporated
Isometric Symbols Customization
Customization of isometric symbols
To place a fence around a customized symbol.
14 Click Create cell.
15 Select custom.cel from the Cell Library selection list and type in. Cell Name: GATFL Description: Customized GATFL
16 Click OK. The new cell is created. Note: To save graphics as an iso cell at least one connection point is needed.
As we were using a graphics of an existing symbol, connection points were already specified. If not we would have to use Place Connect Point.
Note: If required we can also place Origin Point or Intersection Point (for example for Tee components) from the Create Cell toolbar.
Isometric Symbols Customization
52
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Customization of isometric symbols
Note: During the Isometric drawing creation Isometric Manager first tries to
locate a symbol in the custom.cel library and if the required symbol is not found there it is taken from the default library isocomp.cel. It enables us to use the original name GATFL for the new customized symbol. Note: To find a name of a cell used by the Isometric Manager open an
Isometric drawing containing a symbol of a corresponding component and hover the pointer over it.
Note: When the cell is not present in the cell libraries during creation a red
circle will appear at the position of the missing cell. Hovering over the red circle will show the name of the missing cell. 17 Exit OpenPlant Modeler. 18 Click Close. The Isometric Configuration dialog closes. 19 Generate an Isometric drawing containing flanged Gate Valve to see your customized symbol.
Jul-11
53
Copyright © 2011 Bentley Systems, Incorporated
Isometric Symbols Customization
Module Review
Module Review Now that you have completed this module, let’s measure what you have learned.
Questions 1
True/False: Symbols to be placed on Isometric Drawings are defined in the file isoseed.dgn located for the IFC Isometric Style in C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\I FC\Config
2
True/False: To define new isometric symbols you have to use standard MicroStation drawing tools and to draw them from scratch.
3
True/False: When the cell is not present in the cell libraries during creation an empty space will appear at the position of the missing cell.
Answers 1
False: Isometric symbols are stored in cell libraries. Isometric Manager enables to define a set of isometric symbols independently for each Isometric Style. For example libraries used for the Isometric Style IFC are located in C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\I FC\Cell\
2
False: OpenPlant Isometric Manager offers a set of iso symbol templates which were used to create an existing cell library and can be also used to define new symbols to be placed on Isometric Drawings. These templates are located in C:\ProgramData\Bentley\OpenPlantIsometricsManagerV8i\WorkSpace\O PIM\cellTemplates
3
False: When the cell is not present in the cell libraries during creation a red circle will appear at the position of the missing cell. Hovering over the red circle will show the name of the missing cell.
Isometric Symbols Customization
54
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
ProjectWise Connection Module Overview There is a direct connection between OpenPlant Isometric Manager and ProjectWise. The administrator will need to create the connection and specify the behavior of Isometric Manager to meet company requirements.
Module Prerequisites •
Students should have completed the OpenPlant Modeler User course.
•
Students should have understanding of OpenPlant Modeler.
•
Students should have working knowledge of ProjectWise Explorer.
Module Objectives After completing this module, you will be able to:
Jul-11
•
Set Root Storage Folder to store Isometric Drawings.
•
Allow Design Style switching.
•
Set rules for transfer of Isometric drawings between Isometric Manager and ProjectWise folders.
55 Copyright © 2011 Bentley Systems, Incorporated
ProjectWise Connection
ProjectWise Settings for Isometric Drawings
ProjectWise Settings for Isometric Drawings Isometric Manager enables you to post generated Isometric drawings to ProjectWise and perform additional tasks. There are several settings which influence this process: •
Root Storage Folder
•
Allow To Create Folders
•
Allow Design State Switching
•
Document Posting
Exercise 1: Root Storage Folder When you successfully generate an Isometric drawing you can post it to ProjectWise. The goal of this exercise is to configure Isometric Manager to select the Training_Isometrics folder as a root folder for storing Isometric drawings when you initiate the Post to ProjectWise procedure.
1
Select Tools > Configuration or click the Configuration icon.
2
Select Project.
3
Click Browse in the Root Storage Folder field.
4
Navigate to ROOT which corresponds to the Documents folder in the ProjectWise datasource folder structure.
ProjectWise Connection
56
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
ProjectWise Settings for Isometric Drawings
Jul-11
5
Right-click and select New Folder.
6
Type Training_Isometrics in the Name field.
7
Type Training Isometrics in the Description field.
8
Click OK.
57
Copyright © 2011 Bentley Systems, Incorporated
ProjectWise Connection
ProjectWise Settings for Isometric Drawings
The new root folder Training_Isometrics is created and the Isometric Configuration dialog returns.
9
Select True in the Allow to Create Folder field.
This setting will enable automatic creation of subfolders below the Isometric Root Storage folder inside ProjectWise. Subfolder structure is specified by the Property Storage Path assigned to the Class Name Iso Sheet in the schema OpenPlant_3D_Supplemental_Modeling.08.11.ecschema.xml. This
ProjectWise Connection
58
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
ProjectWise Settings for Isometric Drawings
schema is located in C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Schemas.
If set as above, ProjectWise will automatically create a folder structure below the Training_Isometrics folder which will be done by SERVICE , UNIT and LINENUMBER of a pipeline posted by Isometric Manager to ProjectWise. 10 Click Save. To store changes in the ProjectWise Folder Setting dialog. Note: You can start ProjectWise, login into the OP_Training_M datasource and
check the Training_Isometrics folder that was created below the Documents folder.
11 Click Close.
Jul-11
59
Copyright © 2011 Bentley Systems, Incorporated
ProjectWise Connection
ProjectWise Settings for Isometric Drawings
To close the Isometric Configuration dialog.
Exercise 2: Design State Switching When an Isometric drawing is created and put into ProjectWise the Design State of the components used to create an Isometric drawing can be automatically changed. This exercise will teach you how to allow Design State Switching to change the design state of Iso Sheets for the Isometric drawing from the Isometric Style IFC to the Design State IFC. 1
Select Tools > Configuration or click the Configuration icon.
2
Select Project. To open the General window.
3
Select True from the Allow Design State Switching field.
4
Click Save.
5
Expand the Isometric Style node and select IFC. The Isometric Style window opens.
ProjectWise Connection
60
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
ProjectWise Settings for Isometric Drawings
6
Select IFC from the Completed Isometric Design State field.
7
Click Save. The changes are saved.
8
Click Close.
9
The Isometric Configuration dialog closes.
Exercise 3: Document Posting An Isometric Manager administrator can specify what has to be done after an Isometric drawing generation. The goal of this exercise is to enable Isometric drawings to be reviewed before posting them to ProjectWise and to delete them from the Isometric drawings list (right bottom part of the Isometric Manager interface) at the moment they are posted to ProjectWise. 1
Select Tools > Options or click the Options icon. The following dialog opens.
Note: What happens with generated Isometric Drawings depends on setting
of Document Posting options. 2
Jul-11
Set Review generated isometrics before posting .
61
Copyright © 2011 Bentley Systems, Incorporated
ProjectWise Connection
ProjectWise Settings for Isometric Drawings
Note: If the Review generated isometrics before posting option is set the
generated Isometric drawing is available for reviewing when generated. If this option is not set the Isometric drawing is immediately sent to ProjectWise when generated.
3
Set Delete document from system after posting.
Note: If the Delete document from system after posting option is set the
generated Isometric drawing disappears from the list of generated Isometric drawings when posted to ProjectWise. If this option is cleared the generated Isometric drawing does not disappear from the list of generated Isometric drawings when posted to ProjectWise. The Progress Message is changed to Isometric Posted Successfully.
4
Clear List only those components that have Valid Design States .
Note: If the List only those components that have Valid Design States option is set , only Iso Sheets that have a valid design state (as determined by the
administrator) are displayed in the Iso Sheets pane of the interface. 5
Clear Log Isometric Dataset.
Note: Whenever an Isometric drawing is generated, a Production Log file is
created containing information on the isometric generation process. When the Log Isometric Dataset option is set , a complete dataset for the isometric is logged into the Production Log file which can be used for debugging if the isometric generation fails. When you clear the ProjectWise Managed Workspace dgn path, the next time you start Isometrics Manager in a managed workspace you will have to use the setup process again to identify a new file path for the workspace. 6
Click OK. The Options dialog is closed.
ProjectWise Connection
62
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Module Review
Module Review Now that you have completed this module, let’s measure what you have learned.
Questions 1
True/False: The Allow to Create Folders option enables to create a new root folder to store Isometric Drawings.
2
True/False: Each Iso Sheet has to have a Design State defined. When you set the Allow Design State Switching option to True Design State automatically changes to the next state as specified by pre-defined workflow when you generate an Isometric Drawing from it.
3
True/False: If the Delete document from system after posting option is checked the Iso Sheet used for an Iso Drawing generation disappears from the list of IsoSheets available for processing.
Answers
Jul-11
1
False: The Allow to Create Folders option enables automatic creation of subfolders below the Isometric Root Storage folder inside ProjectWise. Subfolder structure is specified by the Property Storage Path assigned to the Class Name Iso Sheet.
2
False: Each Iso Sheet has to have a Design State defined. When you set the Allow Design State Switching option to True for a project it is possible to specify the Completed Isometric Design State value for each Isometric Style. Next time you generate an Isometric Drawing a Design State of Iso Sheet automatically changes to a state as specified for this Isometric Style.
3
False: If the Delete document from system after posting option is checked the generated Isometric Drawing disappears from the list of generated Isometric Drawings when posted to ProjectWise. If this option is not checked the generated Isometric Drawing does not disappear from the list of generated Isometric Drawings when posted to ProjectWise. Just the Progress Message is changed to Isometric Posted Successfully.
63
Copyright © 2011 Bentley Systems, Incorporated
ProjectWise Connection
Module Review
ProjectWise Connection
64
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Management of PCF files Module Overview The Isometric Manager can create PCF files during Isometric drawings generation which can be used by other applications. A system administrator has a several options connected with creation and evaluation of these PCF files.
Module Prerequisites •
Students should have completed the OpenPlant Modeler User course.
•
Students should have understanding of OpenPlant Modeler.
•
Students should have working knowledge of ProjectWise Explorer.
Module Objectives After completing this module, you will be able to:
Jul-11
•
Allow PCF files generation.
•
Influence Isometric Drawing generation if generation of a PCF file fails.
•
View or export PCF files.
65 Copyright © 2011 Bentley Systems, Incorporated
Management of PCF files
Generate PCF files for passing data to legacy systems
Generate PCF files for passing data to legacy systems The Isometric Manager can create a PCF file as a by-product during the Isometric drawing generation. These PCF files can be used by other applications. The Isometric Manager offers several options and features connected with PCF file generation.
Exercise 1: PCF Files Generation The Project Configuration tool enables you to specify if a PCF file will be generated with an Isometric drawing or not. If the Allow PCF File Generation value is set to True a PCF file will be generated. If it is to False a PCF file will not be generated. This exercise will show you how to configure Isometric Manager to generate a PCF file. 1
Select Tools > Configuration or click the Configuration icon.
2
Select Project.
3
Expand the PCF Generation Section window.
4
Select True from the Allow PCF File Generation field, if not already selected.
Note: False doesn't allow PCF file generation.
Another parameter which can be set for a project by the Isometric Configuration tool is called Can Post PCF to ProjectWise. The value specified in this field enables or disables sending generated PCF files to ProjectWise. If the Can Post PCF to ProjectWise value is set to True a PCF file will be posted to ProjectWise together with a generated Isometric drawing. If it is set to False a PCF file will not be sent to ProjectWise. 5
Select True from the Can Post PCF to ProjectWise field, if not already selected.
The last value to be set in the PCF Generation section is Stop Isometric Generation if PCF Fails .
Management of PCF files
66
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Generate PCF files for passing data to legacy systems
If the value specified in this field is set to True an error during a PCF file generation will cause termination of an Isometric drawing generation. If the value specified in this field is set to False an error during a PCF file generation does not influence an Isometric drawing generation. 6
Select True in the Stop Isometric Generation if PCF Fails field.
7
Click Save.
8
Click Close. The Isometric Configuration dialog is closed.
Exercise 2: Viewing and exporting of a PCF Files 1
Select an Isometric drawing, right-click and select PCF File.
Note: Create a new Isometric drawing before step 1 if none is currently
available in the Isometric Manager.
Jul-11
67
Copyright © 2011 Bentley Systems, Incorporated
Management of PCF files
Generate PCF files for passing data to legacy systems
2
The PCF file connected to the selected Isometric drawing is opened in Notepad. You can browse through it now.
3
Select File > Exit. Notepad closes.
4
Management of PCF files
Select an Isometric drawing again, right-click and select the Post to ProjectWise.
68
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Generate PCF files for passing data to legacy systems
5
Launch ProjectWise Explorer and navigate to your folder Training_Isometrics.
6
Select the last generated pcf file, right-click and select Export.
The Document Export Wizard starts. 7
Click Next. The following dialog opens.
8
Jul-11
Set Send to Folder - create an unmanaged local copy .
69
Copyright © 2011 Bentley Systems, Incorporated
Management of PCF files
Generate PCF files for passing data to legacy systems
9
Click Browse. To navigate to the target folder.
10 Click Next. 11 Click Finish.
Note: The PCF configuration file Pcf.ini is located in the same directory as
other Isometric Style configuration files, for example for the I sometric Style IFC is found in C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Style s\IFC\Config\. Note: Customization of a PCF output is outside of the scope of this course.
Management of PCF files
70
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Module Review
Module Review Now that you have completed this module, let’s measure what you have learned.
Questions 1
True/False: PCF files are intermediate files created during an Isometric Drawing production.
2
True/False: PCF files are automatically generated together with Isometric Drawing files.
3
True/False: Creation of a pcf file and generation of an Isometric Drawing are independent activities and do not influence each other.
Answers
Jul-11
1
False: The Isometric Manager creates a PCF file as a by-product during an Isometric Drawing generation. These PCF files can be used by other applications.
2
False: PCF files are automatically generated together with Isometric Drawing files but only if the attribute Allow PCF File Generation is set to True. The value False doesn't allow PCF file generation.
3
False: Pcf files and Isometric are created independently but there is available an attribute Stop Isometric Generation if PCF Fails. If it is set to True an error during a PCF file creation causes termination of an Isometric Drawing generation.
71
Copyright © 2011 Bentley Systems, Incorporated
Management of PCF files
Module Review
Management of PCF files
72
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Course Summary Course Summary You have now completed the course and are prepared to customize Isometric drawings to meet corporate standards. Now you will be able to:
Jul-11
•
Use the Isometric Configuration tool.
•
Customize drawing attributes for additional pipeline information.
•
Setup drawing layout and Bill of Material definitions.
•
Customize existing and create new custom isometric symbols.
•
Set Isometric Revision Format.
•
Set connection to ProjectWise for deliverables Management.
•
Allow PCF File Generation.
73 Copyright © 2011 Bentley Systems, Incorporated
Course Summary
Course Review
Course Review Now that you have completed this course, let’s measure what you have learned.
Questions 1
True/False: The engine used by Isometric Manager to create Isometric Drawings is called Isogen.
2
True/False: To be able to create an Isometric Drawing OpenPlant Isometric Manager has to be connected to the ModelServer.
3
True/False: When generating an Isometric Drawing you can select which Isometric Style will be used by the Isometric Manager.
4
True/False: One Design State can be mapped to several Isometric Styles.
5
True/False: Revisions are assigned to Isometric Drawings based on Isometric Revision setting specified for each Design State.
6
True/False: A revision is set to an Isometric Drawing at the momet you send it to ProjectWise.
7
True/False: Design States Color specifies a color used to display Iso Sheets in the Isometric Manager window.
8
True/False: Drawing Attribute Collection is limited to 32 drawing attributes.
9
True/False: Mapping between text nodes and Drawing Attributes is defined in the Openplant_3d_supplemental_isometrics_isoextractor schema.
10 True/False: Assignment of OpenPlant Components to names of iso symbols used by Isometric Manager is done in isoextract.dat file. 11 True/False: When an Isometric Drawing is created and put into ProjectWise the Design State of the components used to create an Isometric Drawing can be automatically changed. A result Design State is defined by the Completed Isometric Design State value specified for a project using Isometric Configuration tool. 12 True/False: One of parameter which can be set for a project by the Isometric Configuration tool is called Can Post PCF to ProjectWise. The value specified in this field enables or disables sending generated PCF files to ProjectWise.
Course Summary
74
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Course Review
Answers 1
False: The engine used by Isometric Manager to create Isometric Drawings is called IsoExtractor.
2
False: The Isometric Manager can work in two modes. You can be connected to the ModelServer and take data for Isometric Drawing from there or to generate Isometric Drawings from imported i-models.
3
False: An Isometric Style to be used for an Isometric Drawing creation is selected automatically based on Design State mapping.
4
False: The same Isometric Style can be mapped to several Design States but to a Design State you can be mapped only to one Isometric Style.
5
True: Revisions are assigned to Isometric Drawings based on Isometric Revision setting specified for each Design State. If no specific Isometric Revision format is specified for a used Design State, system uses Isometric Revision format set for a Project. Isometric Revision format set for a Design Stage has a priority
6
False: A revision is set to an Isometric Drawing during its creation. System checks (in ProjectWise) the last revision of just generated Isometric Drawing and assigns the following one.
7
True: Design States Color specifies a color used to display Iso Sheets in the Isometric Manager window. It helps to distinguish groups of iso sheets in the same Design State
8
False: By default there are available 32 attributes for each Isometric Style to be used on an Isometric Drawing anyway you can add another drawing attributes if required. Each so called Drawing Attribute Collection is specified by the NAME and by the VALUE.
9
False: Mapping between text nodes and Drawing Attributes is defined in the file node2da.txt located for example for the OPModeler_Metric project and As-Built Isometric Style in the folder ...\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\ As-Built\Config.
10 False: Assignment of OpenPlant Components to names of iso symbols used by Isometric Manager is done in Openplant_3d_supplemental_isometrics_isoextractor schema. 11 False: When an Isometric Drawing is created and put into ProjectWise the Design State of the components used to create an Isometric Drawing can be automatically changed. A result Design State is defined by the Completed Isometric Design State value which is specified not for the
Jul-11
75
Copyright © 2011 Bentley Systems, Incorporated
Course Summary
Course Review
whole project but for each Isometric Style separately. To change a predefined value you can use the Isometric Configuration tool. 12 False: Isometric Manager does not enable to post LOG files to ProjectWise. One of parameter which can be set for a project by the Isometric Configuration tool is called Can Post PCF to ProjectWise. The value specified in this field enables or disables sending generated PCF files to ProjectWise.
Course Summary
76
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Appendix A rep_sortgroups.txt The file location: C:\Documents and Settings\All Users\Application Data\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\AsBuilt\Config\ #----------------------------------------------------------------------------# # Define: # - sort groups #
A sort group specifies a group of elements that have more or less equal
#
precedence in the BOM report
# - sort group headers # - distribution of components over the sort groups # # Sort groups determine how part ID's are distributed among the components in #
the isometric,
# - the sort groups provide a mechanism to group logically related components #
(like:FLANGES, VALVES)
# - sort groups have different priorities. The hight the priority the #
Jul-11
lower the part ID's of the components in the group will be
77 Copyright © 2011 Bentley Systems, Incorporated
Appendix A
rep_sortgroups.txt
# - components in the same sort group get sequential PART ID's # # The specification for a sort group is like: # # SORTGROUP = sort group name, free to choose # HEADER = specification for header line in report when SORTHEADERS = 1 is #
specified in the report definition. One can speciy up to 10
#
lines. Normally leading and trailing spaces are trimmed, one can
#
use a '@' as placeholder for a space
# RULE
= Specifies a regular expression (regex) on the attributes of a
#
component. If the rule evaluates to true the component is added
#
the sortgroup. Multiple RULE lines can be specified, any rule that
#
evaluates to true makes the component part of the sort group
# # - One can define up to 50 sort groups # - the rules within a sortgroup defined the ordering within the sort group. # the earlier a rule is satisfied, the lower the partID will be # - The sort group order is the order in which the sort groups are defined # we probably will add an explicit ORDER= line #----------------------------------------------------------------------------SORTGROUP = PIPES HEADER = @ ----------HEADER = @ PIPES HEADER = @ ----------RULE = IE_TYPE=CT_PIPE RULE = IE_TYPE=CT_BEND
Appendix A
78
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
rep_sortgroups.txt
SORTGROUP = GASKETS HEADER = @ ----------HEADER = @ Gaskets HEADER = @ ----------RULE = IE_TYPE=CT_GASKET
SORTGROUP = BOLTS HEADER = @ ----------HEADER = @ Bolts HEADER = @ ----------RULE = IE_TYPE=CT_BOLT
# this is the dump sortgroup for all the component not specifically assigned SORTGROUP = OTHER HEADER = @ ----------HEADER = @ Not yet grouped HEADER = @ ----------RULE = IE_TYPE=CT_.*
Jul-11
79
Copyright © 2011 Bentley Systems, Incorporated
Appendix A
rep_sortgroups.txt
Appendix A
80
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
Appendix B report.def The file location: C:\Documents and Settings\All Users\Application Data\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Isometrics\Styles\ As-Built\Config\ #----------------------------------------------------------------------------# # Report definition file # # This file contain the defintions for all reports produced by IsoExractor. # # IsoExtractor reports are generic reports that operate on component attributes # Reports generated are plain text files that can be attached to a text node in the # drawing. A report definition is a combination of specification and a script. # # REPORT = Specifies the extension given to the report. The basename #
of the report is the same as the isometric DGN, the report is written
#
to the IE_REPORTDIR directory
# # INCLUDE = Provides a rule which components are to be included in the report. The #
rule operates on the component attributes. There can be multiple
#
INCLUDE lines. Any INCLUDE line satisfied includes the component in the
#
report
# # EXCLUDE = same as INCLUDE but this time to specify that a component should not
Jul-11
#
be in the report. Multiple EXCLUDE lines are allowed. Any EXCLUDE
#
line satisfied excludes the component from the report.
81 Copyright © 2011 Bentley Systems, Incorporated
Appendix B
report.def
# # COLUMN = : : # #
Specifies a column in the report, consists of three fields separated
#
by a colon character.
# #
specifies the width of the column in character positions
# #
a combination of:
#
L left aligned
#
R right aligned
#
C centered
#
W wrap, a new line will be added if the length of the expression
#
exceeds the width of the report
# # # #
An expression for the content of the report column. Any component attribute or string can be used. Example: IE_DESCRIPT + UUID + "and a string"
#
would concatenate the atributes IE_DESCRIPT and UUID and the string
#
"and a string"
# # SEP #
= column separator. Can be any combination of characters, a '@' is used as a space placeholder. The default SEP is the empty string
# # NODE = specifies the text node number in the isometric the report will be #
attached to
# # SORTHEADERS = specifies if sort group headers are to be used (see: rep_sortgroups.txt) #
1 = use sortgroup header
#
0 = dont
# # TEXT = Specifies a line to be written to the report. '@' acts as a placeholder for a space # # WRITE = Write this or another report. When empty the report is written according to #
Appendix B
the COLUMN, INCLUDE, etc statements
82
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
report.def
#
When a report extension is specified than that report is included
# # GROUP = a list of attributes that defined which component are grouped together #
thus using the same line in the report (increasing the quantity). Attributes
#
are comma separated
# SORT = sort the list on a set of attributes value. Consiste of a comma separated list #
of attributes with an optional descending/ascending order. Example:
#
SORT = ,
#
sortspec (optional) is a combination of:
#
D descending
#
N numeric sort
# # There is a set of attributes added by the software: # # SPOOLID
the name of the spool (if any) a component is part of
# PARTID
the part ID of the component
# CUTID
the pipe cut ID a component is part of (only for pipes/bends)
# # IE_FIELD
1 if component is determined field, 0 if component is shop
# IE_LINENAME the line name # # Reserved keywords # QUANTITY
the nett quantity of the component, normally length for pipe/bend
#
items, piece count for piece items. The quantity for pipes is
#
formatted to the unit used
# SIZE1
the main component diameter. Formatted to the unit used
# SIZE2
the run size or branch size if this is different from SIZE1
# SIZE3
the branch size if this is different from SIZE1 & SIZE2
# #----------------------------------------------------------------------------#----------------------------------------------------------------------------# A sample report that writes shop material to a report #----------------------------------------------------------------------------REPORT = SHP
# this to include only shop material
Jul-11
83
Copyright © 2011 Bentley Systems, Incorporated
Appendix B
report.def
INCLUDE = IE_FIELD=0
COLUMN = 3: R : PARTID COLUMN = 19: R : QUANTITY COLUMN = 7: R : SIZE1 COLUMN = 7: R : SIZE2 COLUMN = 2: : COLUMN = 30: W : IE_DESCRIPT COLUMN = 30: : IE_ITEMCODE
GROUP = PARTID SORT = PARTID:N SEP = @ SORTHEADERS = 1
TEXT = @ ---------------------------------------------------------TEXT = @
Shop Materials
TEXT = @ ---------------------------------------------------------Write = END
#----------------------------------------------------------------------------# A sample report that writes field material to a report # Defintion is the same as for the SHP report except for the INCLUDE line #----------------------------------------------------------------------------REPORT = FLD
# this to include only field items INCLUDE = IE_FIELD=1
COLUMN = 3: R : PARTID COLUMN = 19: R : QUANTITY COLUMN = 7: R : SIZE1 COLUMN = 7: R : SIZE2 COLUMN = 2: : COLUMN = 30: W : IE_DESCRIPT
Appendix B
84
Copyright © 2011 Bentley Systems, Incorporated
Jul-11
report.def
COLUMN = 30: : IE_ITEMCODE
GROUP = PARTID SORT = PARTID:N SEP = @ SORTHEADERS = 1
TEXT = @ ---------------------------------------------------------TEXT = @
Field Materials
TEXT = @ ---------------------------------------------------------Write = END
#----------------------------------------------------------------------------# The COMBI report combine the SHP and FLD report into a single report # and attaches it to textnode 60 in the isometric #----------------------------------------------------------------------------REPORT = combi WRITE = shp TEXT = @ TEXT = @ WRITE = fld NODE = 60 END
#----------------------------------------------------------------------------# The CUT report lists the pipe cut pieces # Attaches to text node 61 #----------------------------------------------------------------------------REPORT = CUT INCLUDE = IE_TYPE=CT_PIPE|CT_BEND COLUMN = 6:C:CUTID COLUMN = 7:R:SIZE1 COLUMN = 21:R:QUANTITY COLUMN = 3:R:
Jul-11
85
Copyright © 2011 Bentley Systems, Incorporated
Appendix B