N°:10.6.10.01.00 Issued on: 01.06.08 Revision: 0 By: R. van Eck
Method tho d Stateme Statement nt for Application Appl ication of Sikafloor ®-263 SL
n o i t c u r t s n o C
Scope:
Application of Self-levelling Wear Resistance Epoxy Flooring System (1.5 – 3.0mm)
The information contained herein and any other advice are given in good faith based on Sika’s current Knowledge and experience of the products when properly stored , handled and applied under normal conditions in accordance with Sika’s recommendations. The information only applies to the application(s) and product(s) expressly referred to herein and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the application such as changes in substrates etc, or in case of a different application consult Sika’s Technical Service prior to using Sika products. The information contained herein does not relieve the user of the products from testing them for the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request.
Sika UAE, Divi Divi sion of Geap Traders Traders L.L.C./ L.L.C./ P.O. Box 36334, Dubai, U.A.E. Phone: +971 4 286 8656/ Fax: +971 4 286 8657/ E-mail:
[email protected] 1/4
N°:10.6.10.01.00 Issued on: 01.06.08 Revision: 0 By: R. van Eck
Products • • •
Sikafloor ® -161 Sikafloor ® -263 SL Sikadur ® -504
Description •
Sikafloor ® -161 is a low viscosity, solvent free, 2-component epoxy primer, for use on absorbent substrates. Sikafloor ® -263 SL is a 2-component, economic, multi-purpose, epoxy resin based binder. Sikadur ® -504 is a selected quartz sand of special gradings used as component C (filler) for Sikafloor ® self-levelling systems (0.08–0.2mm).
n o i t c Flooring System Approx. 0.15-0.5 kg/m Sikafloor -161 u Primer Self-levelling Approx. 1.9 kg/m mixture /1mm Sikafloor -263 SL r thickness + Sikadur -504 (1:1) t mortar s n Preparation o Surface Substrate should be sound, clean, dry, fine gripping, free from dust, loose particles, cement laitance, oil, grease or any other contamination. C This can be mechanically achieved by e.g. captive shotblasting, sandblasting or •
•
®
2
®
2
®
* Add approx. 1.0-1.5% Extender T by weight of Epoxy material for sloped areas (Ramps & skirting)
•
•
•
•
•
equivalent methods. Note: Surface contamination can be removed by high pressure water jetting (Min. 150 bar) with the addition of suitable detergents. Concrete parts where oil has penetrated into the concrete must be removed mechanically. Oil contamination can be checked by dropping water onto the surface. If a hydrophobic effect is visible, the surface is contaminated. Repair minor damages, honeycombing or defects in the concrete surface with Sikagard® -720 EpoCem ® or Sikafloor ® -161 Mortar . Larger breakouts can be repaired with Sikadur ® -31/41. The substrate must have a minimum compressive strength of 25 N/mm2 and minimum surface tensile (pull-off) strength of 1.5 N/mm 2. The moisture content of the substrate must be below 4%; other wise, a temporary moisture barrier with 2mm minimum thickness of Sikafloor ® -81 EpoCem ® must be used. Thorough vacuuming before priming is absolutely necessary.
Sika UAE, Divi sion of Geap Traders L.L.C./ P.O. Box 36334, Dubai, U.A.E. Phone: +971 4 286 8656/ Fax: +971 4 286 8657/ E-mail:
[email protected] 2/4
N°:10.6.10.01.00 Issued on: 01.06.08 Revision: 0 By: R. van Eck Sikafloor 263 SL + Sikadur 504 Sikafloor 161
Concrete
n Mixing Sikafloor -161 o Stir separately components A and B of Sikafloor -161 well with an electric i then add the full kit of component B into component A and mix with a slow t mixer, speed mixer (300 - 400 rpm) for at least 3 minutes until a homogeneous mixture achieved, taken care to as little air as possible. Place mixed material into a c isclean container and mix again shortly. u Sikafloor -263 SL self-levellin g mor tar (A+B):C = 1:1 pbw r separately components A and B of Sikafloor -263 SL well with an electric t Stir mixer, then add the full kit of component B into component A and mix with a slow mixer (300 - 400 rpm) for at least 3 minutes, then add 1 part by weight of s speed component C Sikadur -504 and mix for a further 3 minutes with the slow speed until a homogeneous mixture is achieved, taking care to entrap as little air n mixer as possible. Place mixed material into a clean container and mix again shortly. o Application C Primer ®
®
®
®
®
:
Apply the primer coat of Sikafloor ® -161 by roller using a consumption of 0.15 0.5 kg/m² depending on absorbency and roughness of the substrate. Ensure complete wetting out of the surface. Wait until tack free before applying following coats (min. 8 hours, max. 24 hours @ 30°C. Important: The concrete must be completely sealed, and shall not have any absorbency prior to the application of the broadcast.
•
• • •
Self-levelling Mortar Pour the Sikafloor ® -263 SL mortar and spread it equally over the area by means of a notched trowel according to the required thickness (4x4 mm notches will give 2mm thickness). Immediately use a spiked roller to remove any entrapped air. Use a consumption of approximately 1.9 kg/m2 of mixture per thickness of 1 mm. Leave the Sikafloor ® -263 SL mortar to cure for at least 5 days (at 30ºC) before full exposure.
Sika UAE, Divi sion of Geap Traders L.L.C./ P.O. Box 36334, Dubai, U.A.E. Phone: +971 4 286 8656/ Fax: +971 4 286 8657/ E-mail:
[email protected] 3/4
N°:10.6.10.01.00 Issued on: 01.06.08 Revision: 0 By: R. van Eck
Remarks • •
•
Maximum substrate application temperature + 35°C Maximum relative humidity shall be less than 80%. For a safe application the ambient temperature must be 3°C above dew point. While curing, protect from dust and direct sun exposure.
Cleaning Clean all tools and equipment immediately after use with Sika® Thinner or Sika ® Colma-Cleaner . Hardened material can only be removed mechanically.
n Health and Safety o For information and advice on the safe handling, storage and disposal of these i products, users must refer to the most recent Material Safety Data t chemical Sheet containing physical, ecological, toxicological and other safety related data. c any additional information, please do not hesitate to consult our Technical u For Services Department. r t s n o C Rodney van Eck Techni cal Manager
Rene Ruh General Manager
Sika UAE, Divi sion of Geap Traders L.L.C./ P.O. Box 36334, Dubai, U.A.E. Phone: +971 4 286 8656/ Fax: +971 4 286 8657/ E-mail:
[email protected] 4/4