THOM-KATT SERIES AND VS-SERIES WARRANTY Putzmeister, Inc. trailer-mounted concrete Thom-Katt pumps are designed and engineered to perform as stated on published specifications. Only quality material and workmanship are used in the manufacture of these products. With proper maintenance and periodic service, this equipment will provide excellent service. Putzmeister, Inc. warrants each new machine to be free of defects in material and workmanship under normal use and service for a period of twelve (12) months from date of delivery to initial user, or 1100 pumping hours, whichever comes first. This warranty is issued only to the initial user and promises that Putzmeister, Inc. manufactured products are free from defects in material and factory workmanship. Said warranty is void if the machine is subject to misuse, neglect, accident or abuse. The warranty period begins when the machine is delivered to the initial user, or when first put into service, whichever occurs first. Putzmeister’s obligation under this warranty is limited to correcting, without charge, at its factory, any part or parts thereof which shall be returned to its factory or authorized distributor, transportation prepaid, and upon examination proves to Putzmeister’s satisfaction to have been originally defective. Correction of such defects by repair or replacement shall constitute fulfillment of all obligations to the initial user. This warranty does not include labor or transportation charges nor shall it apply to a machine upon which repairs or alterations have been made, unless authorized by Putzmeister. This warranty does not apply to normal maintenance service or to normal replacement of certain machine parts (such as concrete cylinders, valve mechanisms, delivery systems, etc.) which are subject to normal wear. Putzmeister makes no warranty in respect to Engines, trade accessories or outside purchased components, such being subject to the warranties of their respective manufacturers. THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Putzmeister shall not be liable for loss, damage or expense directly or indirectly from the use of its products or from any cause. No person, firm or corporation is authorized to assume for Putzmeister any other liability in connection with the sale of these machines. T.D. Set – TKAE-E
Hydraulic Schematic: Date: 11/04/02
A008234 Revision: A
TK40, TK50, KATT-KRETER w/RS400A
Item # 101 102 102a 102b 103 105 106 109 113 114 114a 114b 115 118 119 120 121 123 127 . . 128 129 132 . 133 134 135 141a 141b 142 148 150 157 162 165 167 168 169 175 182 187 187a 188 197 200
Qty. 2 3 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1 1 1 2 1 1 2 1 1 1 2 1 1
p. 2 of 2 By: AK
PUTZMEISTER-RACINE 1733 90th Street Sturtevant, WI 53177 Phone: (414) 886-3200
PN
Description
261092006 044000008 311927 044153007 311997 311998 311976 262840008 312776 311658 A023002 A023000 238130001 311680 312777 311944 311690 A020042 A012029 A012030 A012031 A013016 A013017 066368003 --A015022 311660 A014021 311666 311808 139884 A041362 311934 067860005 311702 311935 242591005 A041403 311679 224079008 311925 311638 A023001 A094016 311719 A020040
Hyd. Drive Cylinder 1000-80/45 Check Valve, SA5 Check Valve, 75psi Check Valve, SA5 Shift Control Valve, 12V Main Control Valve, 12V Main Control Block, Bare Shift Cylinder, 60mm x 160mm Pressure Gauge for High Pressure, 0-6000psi 1-Spool Valve for Remixer (Optional) 2-Spool Valve for Remixer & Water Pump (Optional) 1-Spool Valve for Water Pump (Optional) Hydraulic Motor for Remixer (Optional) Accumulator Loading Valve Pressure Gauge for Accumulator, 0-3000psi Accumulator, 1gallon Accumulator Discharge Valve, 12V Volume Control Assembly Main Pump, HA10VO71 (TK40) Main Pump, HA10VO100 (TK50) Main Pump, H-A10VO100 (Katt-Kreter) Gear Pump for Accumulator Gear Pump for Accumulator and Optional Equipment (Optional & Replaces Item 128) Oil Cooler (TK40) Oil Cooler – Engine mounted (TK50 & Katt-Kreter) Return Filter Assembly (Head & Element), 43psi bypass Return Filter Element Hydraulic Oil Tank Suction Strainer, 3” Suction Strainer, 1.5” Orifice, ø0.031” Pressure Gauge, 43psi bypass Thermometer and Level Indicator Thermo Probe for Cooler (55ºC) (TK40) Hydraulic Motor for Water Pump (Optional) Drain valve Orifice, ø1.8mm Orifice, ø9.1mm Pressure Limiting Valve for Accumulator Orifice, ø6mm Pressure Limiting Valve 3-Spool Valve for Hydraulic Outriggers and Remixer (Optional) 2-Spool Valve for Hydraulic Outriggers (Optional) Hydraulic Outrigger Cylinders 2”X14” (Optional) Alternating Check Valve Main Control Block Assembly
7+( )2//2:,1* &$87,216 '(6&5,%( $33/,&$7,21 $1' ,167$//$7,21 ,1)250$7,21
'2 127 ,167$// &21752/ &$%/(6 21 $1< $33/,&$7,21 :+,&+ 0$< (;&((' $1< 2) 7+( '(6,*1 3$5$0(7(56 2) 7+( &21752/ &$%/(
&$%/(&5$)7 &21752/ &$%/(6 $5( '(6,*1(' $1' $66(0%/(6 72 %( 1215(3$,5 $%/(
'2 127 $77(037 72 02',)< 7+,6 &21752/ &$%/(
&$%/(&5$)7 &$%/(6 $5( '(6,*1(' 72 %( &217$0,1$17 5(6,67$17 127 &21 &217$0,1$17 3522)
3527(&7 7+( &$%/( )520 &217$0,1$176 68&+ $6 *$6
2,/ ',(6(/ )8(/ :$7(5 ',57 $1' &+(0,&$/6 :+,&+ 0$< '$0$*( 7+( &21752/ &$%/(
3527(&7 7+( &21752/ &$%/( )520 3+<6,&$/ '$0$*( %< 3$,17 .,1.,1* 9,%5$7,21 (&7 :+,&+ 0$< '$0$*( 7+( &21752/ &$%/(
&21752/ &$%/(6 +$9( 7+( %(67 /2$' &$3$&,7< ,1 7+( 38// 02'(
$/:$<6
,167$// 7+( &21752/ &$%/( 62 ,7 38//6 7+( *5($7(67 /2$' $1' 386+(6 7+( 60$//(5 /2$' $1' 38//6 7+( ,7(0 ,172 7+( 1(875$/ 25 2)) 326,7,21
'2 127 ,167$// 7+( &21752/ &$%/( :,7+ 7+( 32:(5 21 25 7+( (1*,1( 5811,1* 6(5,286 ,1-85< 25 '($7+ &28/' 5(68/7
7+( 6:,9(/ $1*/( 0867 %( &(17(5(' :,7+,1 7+( $9$,/$%/( 6:,9(/ $1*/(
7+( 86$%/( 75$9(/ 0867 %( &(17(5(' :,7+,1 7+( $9$,/$%/( 6752.(
7+( )2//2:,1* :$51,1*6 '(6&5,%( ,03257$17 386+38// &$%/( 23(5$7,21 $1' 0$,17(1$1&( ,1)250$7,21
'2 127 $'-867 7+( &21752/ &$%/(
:,7+ 7+( 32:(5 21 25 7+( (1*,1(
5811,1* 6(5,286 ,1-85< 25 '($7+ &28/' 5(68/7
$ *5$'8$/ 25 68''(1 ,1&5($6( ,1 7+( 12/2$' )5,&7,21 &$%/( ',6 &211(&7(' $7 %27+ (1'6 2) $ &21752/ &$%/( ,6 $1 ,1',&$7,21 2) $ 3(1',1* 25 35(6(17 3(5)250$1&( 352%/(0 7+( &21752/ &$%/( 6+28/' %( 5(3/$&(' 27+(5:,6( 6(5,286 ,1-85< 25 '($7+ 0$< 5(68/7
$ *5$'8$/ 25 68''(1 '(&5($6( ,1 7+( 86$%/( 75$9(/ ,6 $1 ,1',&$7,21 2) 3(1',1* 25 35(6(17 3(5)250$1&( 352%/(0 7+( &21752/ &$%/( 6+28/' %( 5(3/$&(' 27+(5:,6( 6(5,286 ,1-85< 25 '($7+ 0$< 5(68/7
&21752/ &$%/(6 :+,&+ +$9( 02,6785( ,16,'( 2) 7+(0 $1'25 +$9( )52=(1 6+28/' %( 5(3/$&(' '2 127 $33/< +($7 72 7+$: 2) '5< &21752/ &$%/(6
&$%/(&5$)7 &21752/ &$%/(6 $5( /8%5,&$7(' )25 7+( /,)( 2) 7+( &21752/ &$%/( '2 127 5(029( 7+( 6($/6 25 /8%5,&$7( 7+( &21752/ &$%/(
&$%/(&5$)7 &21752/ &$%/(6 $5( '(6,*1(' 72 %( 1215(3$,5$%/( '2 127 $77(037 72 5(3$,5 7+,6 &21752/ &$%/(
Putzmeister America 1733 90th Street Sturtevant, WI 53177 Tel. (262) 886-3200 Fax (262) 886-3212
WARRANTY REGISTRATION / IN-SERVICE INSPECTION This warranty registration and in-service inspection form must be completed and returned to Putzmeister America Inc., within fifteen (15) days of the purchase or the in-service date of the unit. Failure to return this form as instructed may void warranty. Warranty claims may not be processed until the unit has been properly registered and inspected.
COMPLETED BY PUTZMEISTER AUTHORIZED DISTRIBUTOR Distributor: ______________________________________________________ Address: ________________________________________________________ City: ___________________________ State: _________ Zip: ____________ Phone: (____)___________________________ Model: _______________ Serial Number: ____________________________ Date Unit Received: ______________ Date Placed In Service: ___________ Hour Meter Reading: _____________
COMPLETE LOWER SECTION IF UNIT IS SOLD Owner: _________________________________________________________ Address: _______________________________________________________ City: ___________________________ State: _________ Zip: ___________ Phone: (___)_________________ Person to Contact: __________________ Date Delivered: _______________ Date Placed In Service: _____________ Hour Meter Reading: _____________