Alcatel-Lucent 7360 INTELLIGENT SERVICES ACCESS MANAGER | RELEASE 4.3 SAFETY MANUAL
3HH-10126-AAAA-TCZZA Edition 01 Released
Alcatel-Lucent Proprietary This document contains proprietary information of Alcatel-Lucent and is not to be disclosed or used except in accordance with applicable agreements. Copyright 2011 © Alcatel-Lucent. All rights reserved.
Alcatel-Lucent assumes no responsibility for the accuracy of the information presented, which is subject to change without notice. Alcatel, Lucent and the Alcatel-Lucent logo are registered trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. Copyright 2011 Alcatel-Lucent. All rights reserved. Disclaimers
Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life-support machines, or weapons systems, in which the failure of products could lead directly to death, personal injury, or severe physical or environmental damage. The customer hereby agrees that the use, sale, license or other distribution of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale, license or other distribution of the products in such applications. This document may contain information regarding the use and installation of non-Alcatel-Lucent products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent tries to ensure that this information accurately reflects information provided by the supplier, please refer to the materials provided with any non-Alcatel-Lucent product and contact the supplier for confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete information provided about non-Alcatel-Lucent products. However, this does not constitute a representation or warranty. The warranties provided for Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by Alcatel-Lucent and its customers. This document was originally written in English. If there is any conflict or inconsistency between the English version and any other version of a document, the English version shall prevail.
When printed by Alcatel-Lucent, this document is printed on recycled paper.
Preface
This preface provides general information about the documentation set for the 7360 Intelligent Services Access Manager (7360 ISAM FX).
Scope This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, CLI and TL1 commands, and software upgrade and migration procedures.
Audience This documentation set is intended for planners, administrators, operators, and maintenance personnel involved in installing, upgrading, or maintaining the 7360 ISAM FX.
Required knowledge The reader must be familiar with general telecommunications principles.
Acronyms and initialisms The expansions and optional descriptions of most acronyms and initialisms appear in the glossary, which is included in the System Description document.
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
iii
Preface
Assistance and ordering phone numbers Alcatel-Lucent provides global technical support through regional call centers. Phone numbers for the regional call centers are available at the following URL: http://www.alcatel-lucent.com/myaccess. For ordering information, contact your Alcatel-Lucent sales representative.
Safety information For safety information, see the Safety Manual for your product.
Documents Refer to the 7360 ISAM Product Information document to see a list of all the relevant customer documents and their part numbers for the current release. Customer documentation is available for download from the Alcatel-Lucent Support Service website at http://www.alcatel-lucent.com/myaccess.
Special information The following are examples of how special information is presented in this document. Danger — Danger indicates that the described activity or situation
may result in serious personal injury or death; for example, high voltage or electric shock hazards. Warning — Warning indicates that the described activity or situation
may, or will, cause equipment damage or serious performance problems. Caution — Caution indicates that the described activity or situation may, or will, cause service interruption.
Note — A note provides information that is, or may be, of special
interest.
Release notes Be sure to refer to the release notes (such as the Customer Release Notes or Emergency Fix Release Note) issued for software loads of your product before you install or use the product. The release notes provide important information about the software load. iv
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
Contents
Preface
iii
Scope ............................................................................................... iii Audience ............................................................................................... iii Required knowledge ................................................................................... iii Acronyms and initialisms ............................................................................. iii Assistance and ordering phone numbers ........................................................... iv Safety information ..................................................................................... iv Documents .............................................................................................. iv Special information.................................................................................... iv Release notes........................................................................................... iv
1—
Conventions 1.1 1.2 1.3 1.4
2—
Safety Guidelines for 7360 ISAM FX Equipment 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9
1-1
Introduction .............................................................................. 1-2 Safety Instructions in Customer Documentation ................................... 1-2 Safety Warning Labels .................................................................. 1-4 Waste from Electrical and Electronic Equipment (WEEE)......................... 1-5
2-1
Introduction .............................................................................. 2-2 Safety Requirements ................................................................... 2-2 Circuit Breakers and Fuses on Shelves for 7360 ISAM FX Equipment ............ 2-7 Fuses on Power Units and Fan Units................................................. 2-10 Environmental Requirements......................................................... 2-14 EMC/EMI ................................................................................. 2-15 Acoustic Noise .......................................................................... 2-15 ITU-T K.20/K.45 Compliance ......................................................... 2-15 Ecology................................................................................... 2-16
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
v
Contents
Index
vi
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
1—
Conventions
1.1 Introduction
1-2
1.2 Safety Instructions in Customer Documentation 1.3 Safety Warning Labels
1-2
1-4
1.4 Waste from Electrical and Electronic Equipment (WEEE)
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
1-5
1-1
1 — Conventions
1.1
Introduction This chapter describes the types of safety instructions used in the Hardware Installation Manual and the Unit Data Sheets. It gives important safety warning labels found on equipment. Note — Familiarize yourself with the safety instructions, warning
labels and their meaning before installing, operating or servicing 7360 FX ISAM equipment.
1.2
Safety Instructions in Customer Documentation Safety instructions are placed in customer documentation where the reader should be warned about dangerous or harmful situations or where he should be informed to ease the work. Safety instructions can be:
• Person-related or combined person-equipment related • Equipment related • Other
1-2
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
1 — Conventions
Person- or Combined Person-Equipment Related Danger — This instruction warns about an immediately threatening
danger. It calls attention to a situation or procedure which, if not correctly performed or adhered to, could result in death or serious physical harm. In addition, it can warn about a possible equipment-damaging situation or give essential information for avoiding degradation of system operation. Do not proceed beyond a danger warning note until the indicated conditions are fully understood and met. Warning — This instruction warns about a possibly dangerous
situation. It calls attention to a situation or procedure which, if not correctly performed or adhered to, could result in death or serious physical harm. In addition, it can warn about a possible equipment-damaging situation or give essential information for avoiding degradation of system operation. Do not proceed beyond a warning note until the indicated conditions are fully understood and met. Caution — This instruction warns about a possibly dangerous
situation. This warning calls attention to a situation or procedure which, if not correctly performed or adhered to, could result in slight injury. In addition, it can warn about a possible equipment-damaging situation or give essential information for avoiding degradation of system operation. Do not proceed beyond a caution note until the indicated conditions are fully understood and met.
Person-Equipment Related Note 1 — This instruction warns about a possibly damaging
situation! It calls attention to a situation or procedure which, if not correctly performed or adhered to, could result in damage to equipment or to objects in the surrounding environment. Note 2 — This instruction gives essential information to avoid
degradation of system operation. Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
1-3
1 — Conventions
Others These instructions do not warn about dangerous or harmful situations, but give information to ease the work. Caution — This Instruction refers to the documentation
The product is marked with this symbol when it is necessary for the user to refer to the instructions in the documentation. Note — Information
This note provides information that makes work easier and other useful information.
1.3
Safety Warning Labels Safety Warning Labels located on equipment call attention to a dangerous situation which, if safety instructions are not correctly performed, could result in bodily harm and/or damage equipment. The following items of labels are mandatory in accordance with IEC60950-1 and IEC60825-1:
• Hazardous voltage; see Figure 1-1 • High temperature; see Figure 1-2 • ESD awareness: Devices and assemblies that are susceptible to ElectroStatic Discharge (ESD) are labelled or tagged with the ESD Awareness symbol; see Figure 1-3 Figure 1-1 Label for Hazardous Voltage Warning
Figure 1-2 Label for High Temperature Warning
1-4
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
1 — Conventions Figure 1-3 ESD Awareness
1.4
Waste from Electrical and Electronic Equipment (WEEE) The product at end of life is subject to separate collection and treatment in the EU Member States, Norway and Switzerland and therefore marked with the WEEE label. Figure 1-4 WEEE Label
Treatment applied at end of life of the product in these countries shall comply with the applicable national laws on wastes from electrical and electronic equipment and more particularly those implementing the European directive 2002/96/EC (WEEE). In countries outside Europe and if not otherwise provided by any mandatory law in those countries where the product is sold, any take back by Alcatel-Lucent of waste electrical and electronic equipment shall be subject to terms and conditions to be agreed upon in writing. Any obligation of Alcatel-Lucent to take back such equipment shall apply only to complete not amended or modified equipment delivered by Alcatel-Lucent, i.e. containing all its components and sub-assemblies. In case Alcatel-Lucent takes back electrical and electronic equipment, Alcatel-Lucent will ensure for the ecological safe and appropriate treatment in accordance with local regulations.
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
1-5
1 — Conventions
1-6
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
2—
Safety Guidelines for 7360 ISAM FX Equipment
2.1 Introduction
2-2
2.2 Safety Requirements
2-2
2.3 Circuit Breakers and Fuses on Shelves for 7360 ISAM FX Equipment 2-7 2.4 Fuses on Power Units and Fan Units 2.5 Environmental Requirements 2.6 EMC/EMI
2-14
2-15
2.7 Acoustic Noise
2-15
2.8 ITU-T K.20/K.45 Compliance 2.9 Ecology
2-10
2-15
2-16
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
2-1
2 — Safety Guidelines for 7360 ISAM FX Equipment
2.1
Introduction This chapter provides general safety guidelines for the:
• 7360 ISAM FX-16 equipment (16-slot shelf) • 7360 ISAM FX-8 equipment (8-slot shelf) • 7360 ISAM FX-4 equipment (4-slot shelf)
2.2
Safety Requirements The 7360 ISAM FX equipment complies with the following safety requirements:
• • • •
IEC 60950-1 EN 60950-1 AS/NZ 60950.1 Protection against electric shock: Class I Danger — Observe safety warnings and instructions
Observe all warnings on the equipment and in the operating instructions. These warn about potentially hazardous situations that could cause injury to persons. Failure to follow these instructions may also lead to equipment malfunction or damage. Carefully follow:
• General safety guidelines in the mandatory regulations • Specific safety guidelines and instructions in the 7360 ISAM FX Hardware installation manual document for procedures during which hazardous situations may occur.
2-2
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
2 — Safety Guidelines for 7360 ISAM FX Equipment
Access Area The 7360 ISAM FX shelves are classified as permanently connected equipment and must be installed in a Restricted Access Location (RAL). The inside of the equipment is classified as service access area in accordance with IEC 60950-1 Warning — Risk of hazardous voltages and electric shock by unintentional contact with circuit inside the shelf, when reaching into the empty card slots or contacting internal circuits.
• Hazardous voltages or electric shock can cause serious personal harm or death • Only qualified service personnel have access to equipment and are allowed to perform installation, operational work or repair work. Caution — Prevention of access
The 7360 ISAM FX shelves must be accessible only by authorized personnel. Install the shelves in a restricted access location or similar environment to prevent unauthorized access.
External Interfaces The interfaces of the 7360 ISAM FX shelves are classified as follows: Table 2-1 External Interfaces Interface
Classification
Optical GE XFP
Class I Laser product
Optical GE SFP
Class I Laser product
Optical FE SFP
Class I Laser product
Optical SFP+
Class I Laser product
EPON SFP
Class I Laser product
GPON SFP
Class I Laser product
Electrical GE
Safety Extra Low Voltage (SELV) circuit
Electrical FE
SELV circuit
BITS
SELV circuit
Craft Terminal
SELV circuit (for configuration purposes by personnel only)
CO Alarm
TNV-2 circuit
External Power Lines
TNV-2 circuit, when using 60 VDC battery SELV circuit, when using 48 VDC battery
Alarm/Service Power Lines
TNV-2 circuit, when using 60 VDC battery SELV circuit, when using 48 VDC battery
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
2-3
2 — Safety Guidelines for 7360 ISAM FX Equipment
SELV
Connect SELV circuits on this equipment only to other circuits that comply with the requirements of the SELV circuits as defined in IEC 60950-1, EN 60950-1 and AS/NZ 60950.1. TNV
TNV can be classified as TNV1, TNV2 or TNV3.
• TNV1 circuits are telecommunications circuits whose voltages during normal operation do not exceed SELV limits but are subjected to off-premises overvoltages. • TNV2 circuits are telecommunications circuits whose voltages under normal operation exceed the SELV limits but are not subject to off-premises overvoltages. TNV2 also classifies dc mains suppliers whose voltages during normal operation exceed 60V but do not exceed 80V. • TNV3 circuits are telecommunications circuits with voltages above SELV limits that are also subject to off-premises overvoltages. Connect TNV circuits on this equipment only to other circuits that comply with the requirements of the TNV circuits as defined in IEC 60950-1, EN 60950-1 and AS/NZ 60950.1.
Equipment Bonding and Grounding The 7360 ISAM FX equipment is classified as Class 1 laser product according to their protection against electric shock. Protection against electric shock is achieved by:
• Using basic insulation • Providing means of connection to the protective earth in the building for those conductive parts that are otherwise capable of assuming hazardous voltages if the basic insulation fails. The 7360 ISAM FX shelves comply with the following product power and grounding standards:
• ETS 300 253, Earthing and bonding of telecommunication equipment in telecommunication centers • ETS 300 132-2, Power supply interface at the input to telecommunication equipment: Part 2 Operated by direct DC current. 7360 ISAM FX equipment is classified as Class 1 Laser Products.
2-4
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
2 — Safety Guidelines for 7360 ISAM FX Equipment
Classification of Laser and LED Transmitter Modules
Normal Laser Operation
The optical fibre communication systems used in the 7360 ISAM FX shelves consist of a laser transmitter module and an optical receiver. Optical connectors have been provided at:
• the front panel of the NT boards • the front panel of the NTIO boards These optical connectors are located behind doors. In normal operation, the laser transmitter is enclosed by the optical connector and the external optical fibre. Laser radiation is always present when the laser unit is powered on, limited to a maximum accessible emission limit of Class 1 according to IEC 60825-1. Laser Transmitter Classification
The 7360 ISAM FX equipment is classified as Class 1 laser product according to IEC 60825-1. LED Classification
According to the current version of IEC60825-1, LEDS do not exceed the accessible emission limit of Class 1 under all conditions of operation, maintenance, service and failure. Warning 1 — Risk of skin burns when in contact with hot parts!
Skin (fingers) can get burns when touching the case of hot devices. The surface temperature must not exceed 70C. Warning 2 — Risk of eye damage by laser radiation
Eyes can get damaged when they are exposed to a laser beam. Observe the laser explanatory label, before plugging in the module. Optical Fiber Communication System Installation Access
According to IEC 60825-2, the laser device, when used in a 7360 ISAM FX shelf that is installed in a rack, is classified as a "hazard level 1" product. The fibre cables pass through the bottom or top rack entrance. The use of cable supports and guides protects the receptacles from strain. The 7360 ISAM FX shelves are located in controlled access locations only (telecom areas) which implies that activity inside the equipment must be executed by trained maintenance personnel only.
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
2-5
2 — Safety Guidelines for 7360 ISAM FX Equipment
Direct viewing in the laser beam is only possible with a disconnected fibre in an open rack.
Equipment Protection
Electrostatic Discharge
Devices and assemblies that are susceptible to ESD are labeled or tagged with the ESD awareness symbol (Figure 2-1). Figure 2-1 ESD Awareness Label
The necessary precautions must be taken to discharge operating personnel by the use of approved discharge straps/links and a conductive layer on the exchange floor. The maximum resistance to discharge must be 106 . Precautions
The following precautions must be observed:
• Wear an antistatic wristband when: • Replacing plug-in units • Operating circuit breakers • The ESD awareness label (Figure 2-1) is present; • Do not wear or use clothes made of wool, nylon, or any synthetic material; such fabrics are major sources of static build-up
• When handling plug-in units, do not use gloves and finger covers, unless they are made of cotton • Always handle the boards by the edges • Do not touch conductor paths with fingers or palms • Remove the antistatic wristband and connection cord after use. They must not be left connected to the shelf or left inside the rack when not used. Earth bonding points for the wristband are provided on the shelf or in the rack and are indicated by the label as shown in Figure 2-2.
2-6
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
2 — Safety Guidelines for 7360 ISAM FX Equipment Figure 2-2 Label for Earth Bonding Point
2.3
Circuit Breakers and Fuses on Shelves for 7360 ISAM FX Equipment This section gives an overview of the power rating of circuit breakers, switches and fuses located on:
• Circuit Breakers on 7360 ISAM FX-16 equipment • Circuit Breakers on 7360 ISAM FX-8 equipment • Fuses on 7360 ISAM FX-4 equipment General Warning Warning — Electrical shock hazard due to battery voltage present at
connectors. Risk of personnel injury at unintentional contact with connectors. The service personnel has to be protected against the battery voltage present on the connectors. Before removing a board from the subrack, switch off the circuit breaker feeding that subrack.
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
2-7
2 — Safety Guidelines for 7360 ISAM FX Equipment
Circuit Breakers on 7360 ISAM FX-16 equipment The circuit breakers of the 7360 ISAM FX-16 shelves are located on the front panel of the power unit of the shelf. The equipment contains two circuit breakers, one for each redundant power branch (BATA and BATB). Figure 2-3 shows the location of the fuses on the FX-16 shelf. Figure 2-3 Fuses on FX-16 Slot Shelf
Circuit breakers
Table 2-2 Circuit Breakers on 8 & 16 Slot Shelf Equipment Type
Circuit Breaker Type
7360 ISAM FX-16 (NFXS-D)
70 A (dual pole 2 x 35 A)
Circuit Breakers on 7360 ISAM FX-8 equipment The circuit breakers of the 7360 ISAM FX-8 shelves are located on the front panel of the power unit of the shelf. The equipment contains two circuit breakers, one for each redundant power branch (BATA and BATB). Figure 2-4 shows the location of the fuses on the FX-8 shelf. Figure 2-4 Fuses on FX-8 Slot Shelf
Circuit breaker
B/40 A
A/40 A
Circuit breaker
Table 2-3 Circuit Breakers on 8-Slot Shelf
2-8
Equipment Type
Circuit Breaker Type
7360 ISAM FX-8 (NFXS-E)
40 A (single pole)
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
2 — Safety Guidelines for 7360 ISAM FX Equipment
Fuses on 7360 ISAM FX-4 equipment The fuses of the 7360 ISAM FX-4 shelves are located on front panel of the power unit of the shelf. The equipment contains six fuses, three for each redundant power branch (BATA and BATB). Figure 2-5 shows the location of the fuses on an FX-4 slot shelf. Figure 2-5 Fuses on FX-4 Slot Shelf
Fuses
Table 2-4 Fuses on 4-Slot Shelf Equipment Type
Fuse Type
7360 ISAM FX-4 (NFXS-F)
10 A (cartridge 5x20mm slow blow, T10AH/250V)
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
2-9
2 — Safety Guidelines for 7360 ISAM FX Equipment
2.4
Fuses on Power Units and Fan Units This section gives an overview of the fuses used on the power units and the fan units of the 7360 ISAM FX-16, FX-8 and and FX-4 shelves.
• • • • • •
Fuses on 7360 ISAM FX-16 Power Unit Fuses on 7360 ISAM FX-8 Power Unit Fuses on 7360 ISAM FX-4 Power Unit Fuses on 7360 ISAM FX-16 Fan Unit (EFCU-E) Fuses on 7360 ISAM FX-8 Fan Unit (EFCU-D) Fuses on 7360 ISAM FX-4 Fan Unit (EFCU-G)
Fuses on 7360 ISAM FX-16 Power Unit Table 2-5 lists the fuses on the power unit (PDBP-B) of the 7360 ISAM FX-16 subrack. Table 2-5 Fuses on NFXS-D Fuse Number
Fuse Rating
Fuse Type
F1
125V/10A
Quick / SMD
F2
125V/10A
Quick / SMD
F3
125V/10A
Quick / SMD
F4
125V/10A
Quick / SMD
F5
125V/10A
Quick / SMD
F6
125V/10A
Quick / SMD
F7
125V/10A
Quick / SMD
R85
72V/900mA
Radial PTC / leaded
R86
72V/900mA
Radial PTC / leaded
R87
72V/900mA
Radial PTC / leaded
R88
72V/900mA
Radial PTC / leaded
R89
72V/900mA
Radial PTC / leaded
R252
72V/1,6A
Radial PTC / leaded
R253
72V/1,6A
Radial PTC / leaded
R254
72V/1,6A
Radial PTC / leaded
R445
72V/900mA
Radial PTC / leaded
R459
72V/900mA
Radial PTC / leaded
R460
72V/900mA
Radial PTC / leaded
Fuses on 7360 ISAM FX-8 Power Unit Table 2-6 lists the fuses located on the power board NGFC-E of the 7360 FX-8 subrack. 2-10
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
2 — Safety Guidelines for 7360 ISAM FX Equipment Table 2-6 Fuses on NGFC-E Fuse Number
Fuse Rating
Fuse Type
F1
125 V / 10 A
Quick / SMD
F2
125 V / 10 A
Quick / SMD
F3
125 V / 10 A
Quick / SMD
F4
125 V / 10 A
Quick / SMD
F5
125 V / 10 A
Quick / SMD
R85
72 V / 900 mA
Radial PTC / leaded
R86
72 V / 900 mA
Radial PTC / leaded
R88
72 V / 900 mA
Radial PTC / leaded
R89
72 V / 900 mA
Radial PTC / leaded
R252
72V/1,6A
Radial PTC / leaded
R253
72V/1,6A
Radial PTC / leaded
R254
72V/1,6A
Radial PTC / leaded
R304
72V/900mA
Radial PTC / leaded
R305
72V/900mA
Radial PTC / leaded
R306
72V/900mA
Radial PTC / leaded
Fuses on 7360 ISAM FX-4 Power Unit Table 2-7 lists the fuses located on the power board NGFC-F of the 7360 FX-4 subrack. Table 2-7 Fuses on NGFC-F Fuse Number
Fuse Rating
Fuse Type
F1
125 V / 10 A
Quick / SMD
F2
125 V / 10 A
Quick / SMD
F3
125 V / 10 A
Quick / SMD
F4
125 V / 10 A
Quick / SMD
F5
125 V / 10 A
Quick / SMD
R85
72 V / 900 mA
Radial PTC / leaded
R86
72 V / 900 mA
Radial PTC / leaded
R87
72 V / 900 mA
Radial PTC / leaded
R88
72 V / 900 mA
Radial PTC / leaded
R89
72 V / 900 mA
Radial PTC / leaded
R252
72V/1,6A
Radial PTC / leaded
R253
72V/1,6A
Radial PTC / leaded
(1 of 2)
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
2-11
2 — Safety Guidelines for 7360 ISAM FX Equipment
Fuse Number
Fuse Rating
Fuse Type
R254
72V/1,6A
Radial PTC / leaded
R413
72V/900mA
Radial PTC / leaded
R414
72V/900mA
Radial PTC / leaded
R415
72V/900mA
Radial PTC / leaded
R416
72V/900mA
Radial PTC / leaded
R461
72V/900mA
Radial PTC / leaded
R462
72V/900mA
Radial PTC / leaded
(2 of 2)
Fuses on 7360 ISAM FX-16 Fan Unit (EFCU-E) Table 2-8 lists the fuses on the 7360 ISAM FX-16 fan unit. Table 2-8 Fuses on 7360 ISAM FX-16 Fan Unit Fuse Number
Fyse Rating
Fuse Type
F1
125V/2,5A
Slow / SMD
F2
125V/2,5A
Slow / SMD
F3
125V/1,5A
Quick / SMD
F4
125V/1,5A
Quick / SMD
F5
125V/1,5A
Quick / SMD
F6
125V/1,5A
Quick / SMD
F7
125V/1,5A
Quick / SMD
F8
125V/1,5A
Quick / SMD
F9
125V/1,5A
Quick / SMD
F10
125V/1,5A
Quick / SMD
Fuses on 7360 ISAM FX-8 Fan Unit (EFCU-D) Table 2-9 lists the fuses on the 7360 ISAM FX-8 fan unit. Table 2-9 Fuses on 7360 ISAM FX-8 Fan Unit Fuse Number
Fyse Rating
Fuse Type
F1
125V/1,5A
Slow / SMD
F2
125V/1,5A
Slow / SMD
F3
125V/1,5A
Slow / SMD
F5
125V/1,5A
Slow / SMD
F6
125V/1,5A
Slow / SMD
(1 of 2)
2-12
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
2 — Safety Guidelines for 7360 ISAM FX Equipment
Fuse Number
Fyse Rating
Fuse Type
F7
125V/1,5A
Slow / SMD
F9
125V/2,5A
Slow / SMD
F10
125V/2,5A
Slow / SMD
(2 of 2)
Fuses on 7360 ISAM FX-4 Fan Unit (EFCU-G) Table 2-10 lists the fuses on the 7360 ISAM FX-4 fan unit. Table 2-10 Fuses on 7360 ISAM FX-4 Fan Unit Fuse Number
Fuse Rating
Fuse Type
F1
125V/1,5A
Quick / SMD
F2
125V/1,5A
Quick / SMD
F3
125V/1,5A
Quick / SMD
F4
125V/1,5A
Quick / SMD
F5
125V/1,5A
Quick / SMD
Fuses on Plug-in Units Table 2-11 gives an overview of the fuse rating of the various plug-in units (with number, rating and type) applied in the 7360 FX subracks. Warning — Risk of malfunctioning due to replacement with wrong
fuse. Applying fuses on plug-in units with ratings different from the prescribed could result in damage to the equipment. Always replace with fuses which have the prescribed rating. Table 2-11 Fuse Rating of Plug-in Units applied in FX subracks Mnemonic
Board Code
Fuse Number
Fuse Rating
Fuse Type
FANT-F
3FE 53699 XX
F1
125V/6.3A
Quick / SMD
F3
125V/0.5A
Quick / SMD
F4
125V/0.5A
Quick / SMD
F5
125V/6.3A
Quick / SMD
F1
125V/3.15
Fuse, quick
F2
125V/0.5A
Fuse, quick
FNIO-B
3FE 54057 AA
(1 of 2)
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
2-13
2 — Safety Guidelines for 7360 ISAM FX Equipment
Mnemonic
Board Code
Fuse Number
Fuse Rating
Fuse Type
NELT-B
3FE 62543 AA
F1
125 V / 500 mA
Fuse, quick
F1P0
125 V / 3.15 A
Fuse, quick
NGLT-A
3FE 64279 AA
F3
125 V / 5 A
Fuse, quick
FPLT-A
3FE 53711 AA
F1
125 V / 4 A
Fuse, quick
F2
125 V / 500 mA
Fuse, quick
F3
125 V / 500 mA
Fuse, quick
(2 of 2)
2.5
Environmental Requirements The 7360 ISAM FX equipment meets the environmental criteria defined by ETS 300 019-1-X: Equipment Engineering (EE): Environmental conditions and environmental tests for telecommunication equipment. The 7360 ISAM FX equipment complies with the following classes:
Storage Storage is according to ETSI EN 300 019-1-1, Class 1.1: Weather protected, partly temperature controlled storage locations.
Transportation Transport according to ETSI EN 300 019-1-2 - Class 2.3:
• Packed, public transportation. • No rain on packing allowed. Stationary Use Stationary use of the 7360 ISAM FX equipment is in accordance with ETS 300 019-1-3 Class 3.1E for multi-shelf configurations:
• Stationary use in temperature controlled locations. Stationary use of the 7360 ISAM FX equipment according ETS 300 019-1-3 Class 3.3* for single-shelf configurations.
• Stationary use in not temperature-controlled locations • No condensation allowed • No conditions of wind-driven rain, snow, hail, water from other sources than rain allowed.
2-14
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
2 — Safety Guidelines for 7360 ISAM FX Equipment
2.6
EMC/EMI The 7360 ISAM FX equipment complies with the following Electromagnetic Compatibility (EMC) and Electromagnetic Immunity (EMI) specifications:
• • • • • • • • • •
ETSI EN 300 382-2 telecommunication centre installation environment ETSI EN 300 386-2 telecommunication centre installation environment ETSI EN 201 468 for telecommunication centres, level 2 EN 61000-4-2 ESD EN 61000-4-3 Radiated immunity EN 61000-4-4 EFT EN 61000-4-5 Surge EN 61000-4-6 Low Frequency common immunity EN 55022, CISPR22, AS/NZS 3548, CLASS B EN 50082-1 and EN 50082-2 (ESD, RF Immunity, EFT etc. - Industrial & Commercial). • CE compliance marking (safety and EMC for Europe) The 7360 ISAM FX equipment complies with and has been CE-marked in accordance with the following European directives:
• 99/05/EC (R&TTE) • 73/23/EEC (LVD as amended by directive 93/68) • 89/336 (EMC as amended by directive 93/68)
2.7
Acoustic Noise The 7360 ISAM FX equipment meets the acoustic noise requirements defined by ETS 300 753: Equipment Engineering (EE); Acoustic noise emitted by telecommunications equipment, category: telecommunication equipment room.
2.8
ITU-T K.20/K.45 Compliance The 7360 ISAM FX equipment is compliant with the following specifications:
• ITU-T K.20 and ITU-T K.45 specifications for the full unit. • In CO deployment, the equipment complies with the enhanced test levels as specified in the ITU-T K.20 recommendation when external 420V primary Gas Discharge Tube (GDT) protectors are used on the external LINE interface. • In remote deployment, the equipment complies with the basic test levels for permanently grounded systems as specified in the ITU-T K.45 recommendation when used in combination with 420V primary protection GDTs on both the POTS and the LINE interface sides.
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
2-15
2 — Safety Guidelines for 7360 ISAM FX Equipment
2.9
Ecology The 7360 ISAM FX equipment complies to:
• Restriction on the use of Hazardous Substances (RoHS) Directive 2002/95/EC • Waste from Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC
2-16
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
Index
F Fuses Plug-in units, 2-13
R requirements acoustic noise, 2-15 EMC/EMI, 2-15 environmental, 2-14 safety, 2-2
S safety instructions, 1-2 requirements, 2-2 warning labels, 1-4
W WEEE, 1-5
Alcatel-Lucent 7360 ISAM R4.3 July 2011 3HH-10126-AAAA-TCZZA Edition 01 Released Safety Manual
IN-1
Index
IN-2
July 2011 Alcatel-Lucent 7360 ISAM R4.3 Safety Manual Edition 01 Released 3HH-10126-AAAA-TCZZA
Customer documentation and product support
Customer documentation http://www.alcatel-lucent.com/myaccess Product manuals and documentation updates are available at alcatel-lucent.com. If you are a new user and require access to this service, please contact your Alcatel-Lucent sales representative.
Technical Support http://www.alcatel-lucent.com/support
Documentation feedback
[email protected]
© 2011 Alcatel-Lucent. All rights reserved. 3HH-10126-AAAA-TCZZA Edition 01 Released