XCAL-Auto Mobile (For RJIL)
User Guide Doc Rev: 00 Product Version: 4.7.xx 2014. 03
XCAL-Auto Mobile User Guide Ⓒ 2014 Accuver APAC Ltd., All rights reserved. This documentation shall not be changed, distributed to the public, and opened to the third person without written permission. Accuver is not responsible for any direct or indirect damages arisen or related to use of this manual. All information included herein may be changed without prior notice.
‘
Accuver APAC Ltd., Unit 206, 2/F., No. 8 Science Park West Avenue, Hong Kong Science Park, Shatin, NT, HONG KONG Tel : +852-2210-7004 Fax : +852-2210-7017 http://www.accuver.com © Copyright by Accuver APAC Ltd.
Page 2
XCAL-Auto Mobile User Guide
Contents
Contents
Master Device Configuration ............................................22 Slave Device Configuration ..............................................23 Destination Configuration .....................................................25 SCFT Station Measurement Configuration ...............................27
Contents ............................................................................................... 3 Overview ............................................................................................... 6 Special Features ................................................................... 7 Specification......................................................................... 7 Getting Started...................................................................................... 8 Connecting PC and Smart Phone ............................................. 9 Installing File Explorer Application (ES File Explorer) ............... 10 Transferring XCAL-Auto Mobile Program File ........................... 11 Starting XCAL-Auto Mobile ................................................................. 13 Switching XCAL-Auto Mobile ................................................. 15 Graphic User Interface ......................................................... 16 XCAL-Mobile ................................................................. 16 XCAL-Auto Mobile .......................................................... 17 Status Icon Bar .................................................................. 18 XCAL-Auto Mobile Menu ................................................. 19 Map ....................................................................... 19 RTP Info ................................................................. 20 Signaling Message ................................................... 21 Master/Slave Configuration .................................................. 22 © Copyright by Accuver APAC Ltd.
SCFT Moving Measurement Configuration ...............................30 Moving Master/Slave Scenario Configuration ...........................32 Cluster Measurement Configuration .......................................34 Cluster Master/Slave Scenario Configuration ...........................36 Upload after Measurement ....................................................38 Log Manager Setting ............................................................40 Terminating XCAL-Auto Mobile ........................................................... 41 RF Information (Qualcomm Chipset).................................................. 43 Summary List of RF Information ............................................45 Android RF..........................................................................46 Signal Messages ..................................................................46 LTE Summary .....................................................................47 LTE Signal ..........................................................................47 LTE Cell ..............................................................................48 RTP Info .............................................................................48 Configuring Logmask .......................................................................... 49 Configuring Logmask Setting ................................................50 Performing AutoCall Test .................................................................... 51 Page 3
XCAL-Auto Mobile User Guide
Creating AutoCall Scenario (For Single Call Test) .................... 52
Other Settings - Naming Log File .....................................91
Creating AutoCall Scenario (For Multiple Call Test) .................. 54
Other Settings - CSV Delimiter ........................................92
AutoCall Test for Sequential Multiple Calls (Multi-Call) ........ 55
Other Settings – Network (RAT/Band) Lock (DM) ...............93
Importing AutoCall Scenario ................................................. 57
Other Settings - RAT & Band Lock (Hidden) .......................94
Starting AutoCall Test (In Classic tab) ................................... 58
Other Settings - External GPS..........................................95
Starting AutoCall Test (In All Scenarios tab) ........................... 60
Other Settings – TTS Alarm .............................................96
Terminating AutoCall Test .................................................... 62
Other Settings – Split log file ...........................................97
Monitoring in Digital Map.................................................................... 63
Master/Slave Test ............................................................................... 98
Displaying Data in Digital Map .............................................. 64
Configuring Master or Slave Mobile ........................................99
Configuring Map Options ...................................................... 65
Starting M/S Test .............................................................. 102
Configuring Map Options – Parameters ............................. 66
Inbuilding Test of Master/Slave Mobiles ................................ 103
Configuring Map Options – Settings ................................. 67
Inbuilding Test .................................................................................. 104
Importing BTS/Repeater Data ......................................... 68
Configuring Inbuilding Test ................................................. 105
Call Result History ............................................................................... 73
Starting Inbuilding Test ...................................................... 108
Uploading Log File ............................................................................... 75
Moving Point Test......................................................... 109
Uploading Setting ............................................................... 79
Fixed Point Test ........................................................... 115
Additional Function ............................................................................. 80
Configuring Inbuilding Options ............................................ 117
Manual Logging .................................................................. 81
Configuring Inbuilding Options – Parameters ................... 118
Replay ............................................................................... 83
Terminating XCAL-Mobile ................................................................. 119
Screen Capture ................................................................... 85
Troubleshooting ................................................................................ 121
About ................................................................................ 86
Related Products ............................................................................... 123
Other Settings .................................................................... 88
Appendix: Configuring AutoCall Scenario ......................................... 124
© Copyright by Accuver APAC Ltd.
Page 4
XCAL-Auto Mobile User Guide
Time Configuration (Voice, Web, Ping, VoLTE) ...................... 125 Time Configuration (FTP) ................................................... 126 Configuration for Each Call Type ......................................... 127 Voice ......................................................................... 127 FTP ............................................................................ 127 Web........................................................................... 128 Ping ........................................................................... 128 VoLTE ........................................................................ 128 Multi Call .................................................................... 129 Appendix: Call Events ....................................................................... 130 Voice ............................................................................... 131 FTP ................................................................................. 131 Web ................................................................................ 131 Ping ................................................................................ 132 VoLTE .............................................................................. 132 Appendix: Parameter Description ..................................................... 133 LTE ................................................................................. 134 Appendix: RTP Analysis in VoLTE ...................................................... 135
© Copyright by Accuver APAC Ltd.
Page 5
XCAL-Auto Mobile User Guide
O
Overveiw
verview
XCAL-Auto Mobile is a test application which can be connected & used with FMS (Fleet Management System) server. XCAL-Auto Mobile can be controlled, configured and monitored in real time basis from FMS server.
XCAL-Auto Mobile operates together with the XCAL-Mobile. XCAL-Mobile, which is an Android based stand-alone application runs on Android smart phones that enables QoS and QoE testing across all WCDMA, GSM, and LTE technologies. XCAL-Mobile application on smart phone in Android OS supports extensive application testing and delivers real-time network measurement and visualization. XCAL-Mobile is provided for both indoor and outdoor measurement while it is also available for field drive test when it is installed inside of a moving vehicle. It supports remote control function by connecting with other server solution series of Accuver. All features can be controlled by using normal handset keys.
© Copyright by Accuver APAC Ltd.
Page 6
XCAL-Auto Mobile User Guide
Getting Started
Special Features Generates and automatically.
Specification
terminates
voice
and
data
calls Technology: LTE Qualcomm
Creates and edits measurement scenarios in portable smart phone. Performs voice and data call measurement simultaneously. Monitors statistics in real-time in message, graph, table, and map. Provides multiple types of call events and parameters for technologies.
Terminal: Android smart phone OS up to Jelly Bean (v4.1) Recommended RAM memory: 812 MB Call Type: Voice, FTP, Web, Ping, VoLTE, Multi Call RF Parameter: Android RF Info, LTE Summary, LTE Signal, LTE Cell
Shows monitoring data in mobile window as the logging file is provided in *.drm(drx) and *.csv format. Supports both indoor and outdoor measurement. Supports Replay mode. Exports logging automatically.
file
to
server
both
manually
and
Reports errors of the program via e-mail automatically.
© Copyright by Accuver APAC Ltd.
Page 7
XCAL-Auto Mobile User Guide
G
Getting Started
etting Started
This chapter describes how to install XCAL-Auto Mobile application in smart phone: How to Connect a PC to an Android-OS smart phone. How to install a file explorer application in Android-OS. How to copy XCAL-Auto Mobile program (*.apk) to Android-OS smart phone.
© Copyright by Accuver APAC Ltd.
Page 8
XCAL-Auto Mobile User Guide
Getting Started
Connecting PC and Smart Phone In order to install XCAL-Auto Mobile application on your smart phone, you first need to connect your smart phone and PC by phone cable.
1. Connect PC and an Android-OS smart phone by phone cable.
© Copyright by Accuver APAC Ltd.
2. Swipe down from the top of smart phone screen to open notification center.
3. Tap USB connected.
4. Tap Turn on USB storage button. 5. PC and Android-OS smart phone is connected successfully.
Page 9
XCAL-Auto Mobile User Guide
Getting Started
Installing File Explorer Application (ES File Explorer) ES File Explorer application helps you to navigate through your smart phone.
1. Tap Market icon on your smart phone to open Android Market.
© Copyright by Accuver APAC Ltd.
2. Android Market main screen appears. Tap Search icon.
3. Search for ES File Explorer.
4. Download and install the ES File Explorer application on your smart phone. ES File Explorer application is successfully installed.
Page 10
XCAL-Auto Mobile User Guide
Getting Started
Transferring XCAL-Auto Mobile Program File You need to copy and paste XCAL-Auto Mobile application file in *.apk format onto your smart phone.
1. In PC, open driver of smart phone.
2. Create a new folder.
3. Copy and paste XCAL-Auto Mobile program file (*.apk) into the new folder.
4. In smart phone, tap ES File Explorer icon to execute.
XCAL-Auto Mobile program file (*.apk) is provided upon purchase.
© Copyright by Accuver APAC Ltd.
Page 11
XCAL-Auto Mobile User Guide
1. Tap the new folder which was created via PC.
Getting Started
2. Tap XCAL-Auto Mobile program file (*.apk) to execute.
3. Tap Install button.
4. XCAL-Auto Mobile application is successfully downloaded and installed.
Make sure that there is enough hard disc capacity in the smart phone. XCAL-Auto Mobile program file (*.apk) is approx. 10 MB.
© Copyright by Accuver APAC Ltd.
Page 12
XCAL-Auto Mobile User Guide
S
Starting XCAL-Auto Mobile
tarting XCAL-Auto Mobile
By now, you have completed all necessary steps before starting and are ready to use XCAL-Auto Mobile application on your smart phone.
Before you start XCAL-Auto Mobile, make sure Settings – Date and time - Auto (Use network-provided values) is checked. Internet access is available (WiFi, 3G or 4G).
© Copyright by Accuver APAC Ltd.
Page 13
XCAL-Auto Mobile User Guide
Prior to using XCALMobile, you should get a valid SW License Key. You may request Accuver sales representative for valid Key by sending your IMSI, IMEI or MAC address information of device.
Starting XCAL-Auto Mobile
1. Tap Check Box of valid Key and License Download button.
2. License Download Screen appears.
3. Main screen of XCALMobile appears.
MAC address will not be shown when internet access (WiFi or 3G or 4G) is unavailable.
© Copyright by Accuver APAC Ltd.
Page 14
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
Switching XCAL-Auto Mobile
1. Execute Change XCALAuto Mobile by clicking menu button.
© Copyright by Accuver APAC Ltd.
2. The above screen appears.
Page 15
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
Graphic User Interface XCAL-Mobile XCAL-Mobile’s intuitive and user-friendly user interface helps your measurement projects.
XCAL-Mobile version Taps Classic or All Scenario tab. XCAL-Mobile version Swipes left and right to select call type. Taps combo box to select Auto Call scenario. Taps combo box to select Auto Call scenario. Shows Scenario details. Starts AutoCall. AutoCall Setting, Call History, Other Setting, Log Upload, Logmask Setting For detail, see Configuring AutoCall Scenario, Call Result History, Uploading Log File, Additional Function Shows data and serving lines in Google AutoCall Setting, Call History, Othermap. Setting, Log Upload, Logmask Setting For detail of call result, see Monitoring in Digital Map.Call Result History, Uploading Log For detail, see Configuring AutoCall Scenario,
File, Additional Function
Shows data and serving lines in Google map. Shows RFofinformation of Monitoring smart phone real-time. For detail call result, see in in Digital Map.
For detail of RF information, see RF Information
Select and start of AutoCall scenario. Showscall RFtype information smart based phoneonincall real-time. For detail of AutoCall test, see AutoCall Test. For detail of RF information, see RF Information Select call type and start AutoCall based on call scenario. For detail of AutoCall test, see AutoCall Test.
© Copyright by Accuver APAC Ltd.
Page 16
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
XCAL-Auto Mobile XCAL-Auto Mobile’s intuitive and user-friendly user interface helps your measurement projects. RTU ID
XCAL-Auto Mobile version Shows Log upload file list. Shows RTU Information For detail, see LTE Summary View. Shows Status/Parameters For detail, see LTE Cell Measurement. Shows Parameters For detail, see LTE Signal View.
Shows Test Scenario details. Starts AutoCall.
Display Map Master/Slave Setting
Starts Idle logging.
Shows RTP Information Change to XCAL-Mobile
XCAL-Auto Mobile Main Window Shows Signaling Message This window is displayed when the user clicks menu button of phone. XCAL-Auto Mobile Menu
© Copyright by Accuver APAC Ltd.
Page 17
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
Status Icon Bar Status Icon Bar is placed at the upper right corner of XCAL-Auto Mobile/XCAL-Mobile screen. Icon
Icon Name AutoCall
Description
Green: AutoCall test is in progress without any problem. Red: AutoCall test is stopped abnormally during running. Gray: AutoCall test is not in progress.
Logging File
Green: Measurement data is properly saving in logging file. Red: Measurement data is stopped saving abnormally in logging file. Gray: Measurement data is not saving in logging file.
DM Data Collection GPS Status
/
Green On: DM data is being collected from modem. Red: DM data is not being collected from modem. : Network GPS is enabled. When it is turned to black, Network GPS is not enabled properly. : GPS information from GPS inside the smart is being collected without any problem. When it is blinking, there is issues with GPS
Master
Master/Slave is working.
/ Slave
The number of small boxes in the icon stand for number of Slave mobiles connected to Master mobile. For details, see Master/Slave Test.
IP Frame
Red: IP Frame function is working. When it is in black, IP Frame function is not enabled. For details, see Other Settings.
© Copyright by Accuver APAC Ltd.
Page 18
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
XCAL-Auto Mobile Menu Map XCAL-Auto Mobile enables you to change map setting in Google map. To open Map Options, tap Menu button on smart phone hardware. Items
BTS On/Off Legend On/Off
Description
Shows/Hides BTS in map. Shows/Hides legend in map.
Route On/Off
Shows/Hides Route in map.
Parameter
Selects parameters of technologies to display in map. Parameter Common : App. DL Thp, APP. UL Thp, Network Type LTE : RSSI, RSRP, RSRQ, SINR
© Copyright by Accuver APAC Ltd.
Page 19
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
RTP Info RTP Info screen shows Rx Packet Loss Rate, Rx RTP Throughput, Rx Inter Arrival Packet Delay, Rx Inter Arrival Packet Jitter, One Way Delay, Rx/Tx RTP Packet Count, and Round Trip Time
Rx Packet Loss Rate
RTT
Rx RTP Throughput
One Way Delay
Rx Inter Arrival Packet Delay
Counterpart UE
Rx Inter Arrival Packet Jitter One Way Delay Rx RTP Packet Count Tx RTP Packet Count
Interarrival Jitter Lost Packet Num Measuring UE Interarrival Jitter Lost Packet Num
R-Factor
© Copyright by Accuver APAC Ltd.
Page 20
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
Signaling Message Signaling Messages screen shows RRC messages of LTE technology.
LTE RRC Messages
Tap
a
message
from
Signaling Message list, and Corresponding code is shown
© Copyright by Accuver APAC Ltd.
Page 21
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
Master/Slave Configuration Master Device Configuration
1. Click M/S.
© Copyright by Accuver APAC Ltd.
2. Click Master when the above screen is displayed.
3. The device is registered as above.
Page 22
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
Slave Device Configuration
1. Click M/S.
© Copyright by Accuver APAC Ltd.
2. Click Slave when the above screen is displayed.
3. Click the device willing to designate as Master. (If this device is registered before, the user directly check the RTU ID.)
Page 23
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
If the Master device is not registered, execute the next level as below
1. Click Settings –Bluetooth. (Execute Master and Slave device both.)
© Copyright by Accuver APAC Ltd.
2. Check My device in Master device. In Slave device, search and click the device in Available devices. And the Bluetooth request window will pop-up.
3. Go back to M/S setting window and click
4. Check the device list. .
Page 24
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
Destination Configuration
1. Get GPS data clicking .
© Copyright by Accuver APAC Ltd.
2. Find desired test location and click long.
3. In Select a destination window, click OK. If change location, click Cancel.
4. The OK is clicked in previous step, the above window is displayed. If use Google Map navigation function, click OK. If not, click Cancel.
Page 25
XCAL-Auto Mobile User Guide
Google Map Navigation Example.
© Copyright by Accuver APAC Ltd.
Starting XCAL-Auto Mobile
5. Click
6. Download site list inside of Cluster clicking RCP in above screen.
Page 26
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
SCFT Station Measurement Configuration
..
1. Click
.
© Copyright by Accuver APAC Ltd.
2. Configure Select Type, Test Type, Site, Cycle in above screen.
3. Configure Select Type.
4. Configure Test type.
Page 27
XCAL-Auto Mobile User Guide
5. Configure Site.
© Copyright by Accuver APAC Ltd.
Starting XCAL-Auto Mobile
6. Configure Cycle. When complete, click Save button.
7. The above screen is displayed when setting is completed. Click Start button.
8. Autocall test is started and the above screen is displayed.
Page 28
XCAL-Auto Mobile User Guide
9. After test, the next station test asking window pops up. If yes, click OK. If no, click Cancel.
Starting XCAL-Auto Mobile
10. When clicks OK, the next station will be set as above.
(After Station6 Test, which is the last station, the window will not pop up.)
© Copyright by Accuver APAC Ltd.
Page 29
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
SCFT Moving Measurement Configuration
..
1. Click
.
© Copyright by Accuver APAC Ltd.
2. Configure Select Type, Test Type, Site, Cycle in above screen.
3. Configure Select Type.
4. Configure Test type.
Page 30
XCAL-Auto Mobile User Guide
5. Configure Site.
© Copyright by Accuver APAC Ltd.
Starting XCAL-Auto Mobile
6. Configure Cycle. When complete, click Save button.
7. The above screen is displayed when setting is completed. Click Start button.
Page 31
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
Moving Master/Slave Scenario Configuration After setting, the scenario is assigned automatically. If want to change the scenario, follow the procedure as below.
1. Select Master Scenario.
© Copyright by Accuver APAC Ltd.
2. Click OK button.
3. Select Slave Scenario.
4. Click OK button.
Page 32
XCAL-Auto Mobile User Guide
5. When Setting is completed, the above screen is displayed. Click Start button.
Starting XCAL-Auto Mobile
6. Autocall test is started and the Slave screen is displayed.
Slave Screen
When Master device is started, the Autocall test is started at the same time with Slave device.
© Copyright by Accuver APAC Ltd.
Page 33
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
Cluster Measurement Configuration
..
1. Click
.
© Copyright by Accuver APAC Ltd.
2. Configure Select Type, Test Type, Site, Cycle in above screen.
3. Configure Select Type.
4. Cluster is configured in automatically.
Page 34
XCAL-Auto Mobile User Guide
5. Configure Cycle in Select Cycle Count. When completed, click Save button.
© Copyright by Accuver APAC Ltd.
Starting XCAL-Auto Mobile
6. When the setting is completed, the above screen is displayed.
Page 35
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
Cluster Master/Slave Scenario Configuration After setting, the scenario is assigned automatically. If want to change the scenario, follow the procedure as below.
1. Select Master Scenario.
© Copyright by Accuver APAC Ltd.
2. Click OK button.
3. Select Slave Scenario.
4. Click OK button.
Page 36
XCAL-Auto Mobile User Guide
5. When Setting is completed, the above screen is displayed. Click Start button.
Starting XCAL-Auto Mobile
6. Autocall test is started and the Slave screen is displayed.
Slave Screen
When Master device is started, the Autocall test is started at the same time with Slave device.
© Copyright by Accuver APAC Ltd.
Page 37
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
Upload after Measurement
1. Click Stop button.
2. Select termination type. Complete: End test. In Progress: Test following this test.
© Copyright by Accuver APAC Ltd.
3. Click OK button to upload. If you don’t want to upload, click Cancel button.
If there is a Slave device, the upload request window will pop up in Master window.
(If check ‘Do not ask again’, the previous set value will maintain without upload request window executing.)
Page 38
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
..
4. Click
.
© Copyright by Accuver APAC Ltd.
5. You can check the above upload list.
Page 39
XCAL-Auto Mobile User Guide
Starting XCAL-Auto Mobile
Log Manager Setting Item Select File Name Filter
Check the user desired log file type.
Auto DRM/DRX upload(Only all scenario)
After Autocall, display DRM/DRX file upload request pop-up or not.
Auto DRM/DRX upload(Do not ask again)
Configure Auto DRM/DRX pop-up executing. It can only configure when Auto DRM/DRM Upload is activated.
FTP Server Setting
© Copyright by Accuver APAC Ltd.
Description
Configure FTP server which uploads the log file.
Page 40
XCAL-Auto Mobile User Guide
T
Terminating XCAL-Auto Mobile
erminating XCAL-Auto Mobile
When you have completed all necessary measurement test with XCAL-Auto Mobile or you want to terminate the application while measurement, you can terminate the application.
Press Home button on smart phone hardware, and XCAL-Auto Mobile application runs in background mode
© Copyright by Accuver APAC Ltd.
Page 41
XCAL-Auto Mobile User Guide
1. When you want to terminate XCAL-Auto Mobile application, tap Back button on smart phone hardware.
© Copyright by Accuver APAC Ltd.
Terminating XCAL-Auto Mobile
2. Select the desired menu. Go to the Background Cancel
3. XCAL-Auto Mobile application is terminated.
Kill the XCAL-Auto Mobile
Page 42
XCAL-Auto Mobile User Guide
R
RF Information (Qualcomm Chipset)
F Information (Qualcomm Chipset)
XCAL-Mobile displays real-time RF information of smart phone. XCAL-Mobile shows following RF parameters. Android RF Signal Messages
LTE Cell RTP Summary
LTE Summary LTE Signal RF parameters in blue color are available depending on device type. For details of parameter description of each technology, see Appendix: Parameter Description.
© Copyright by Accuver APAC Ltd.
Page 43
XCAL-Auto Mobile User Guide
1. In main screen of XCAL-Mobile, tap RF button.
RF Information (Qualcomm Chipset)
2. To select RF parameter, swipe down the green bar at the top of the screen. You can see various RF information view types. Select a view type icon. For details, see next pages.
3. The selected view type screen appears.
Swipe left and right to monitor other RF Information screens. Swipe up and down to monitor more data in a RF Information screen.
© Copyright by Accuver APAC Ltd.
Page 44
XCAL-Auto Mobile User Guide
RF Information (Qualcomm Chipset)
Summary List of RF Information Icon Android RF Signal Message
Description Displays all the information collected from Android OS. Displays Layer3 message for all technologies supported.
LTE Summary
Displays major RF KPIs for LTE in table.
LTE Signal
Displays major RF KPIs for LTE in graph.
LTE Cell RTP Info
Displays signal strength and information from serving and neighbor LTE cells measured by the device. Displays packet analysis from RTP messages when running VoLTE autocall. It contains the following parameters: Rx Packet Loss, Rx RTP Throughput, Rx Delay, Rx Delta Delay, Rx Jitter, One Way Delay, RTP Packet Count, Round Trip Time.
© Copyright by Accuver APAC Ltd.
Page 45
XCAL-Auto Mobile User Guide
RF Information (Qualcomm Chipset)
Android RF
Signal Messages
Android RF screen shows basic RF information provided by Android
Signal Messages screen shows RRC messages of corresponding
OS.
technology. Signal Messages is available depending on device type. Current Network/Phone Type Operator
LTE RRC/NAS messages
Latitude Longitude Data State Current CPU usage Usage/APP Memory Battery AutoCall Log File Size SD Free Space Phone Model Phone OS Ver Rooting DM Time(Received)
© Copyright by Accuver APAC Ltd.
Tap
a
message
from
Signal
Message list, and corresponding code is shown.
Page 46
XCAL-Auto Mobile User Guide
RF Information (Qualcomm Chipset)
LTE Summary
LTE Signal
LTE Summary screen shows LTE Parameters.
LTE Signal screen shows RSRP, RSRQ, RSSI, Tx Power, SINR, CQI,
LTE Summary is available depending on device type.
and Rank Index. LTE Signal is available depending on device type.
RSSI Tx Power PCI (Serving) RSRP (Serving) RSRQ (Serving) SINR (Ant0/1) CQI (CW0/1) Rank Index UL Power Headroom UL/DL RB Num (Avg.) UL/DL MCS (QPSK/16QAM/64QAM) PDSCH/PUSCH BLER PDSCH/PUSCH Throughput UL/DL MAC Throughput. Path Loss Traffic State Wideband PMI MCC/MNC EARFCN (DL/UL) Bandwidth (DL/UL) Band Indicator Tracking Area Code Cell ID (Serving) Allowed Access EMM State/Substate DL/UL Transmission Mode Num of Tx/Rx Antenna
© Copyright by Accuver APAC Ltd.
RSRP (Ant0/1) RSRQ (Ant0/1) RSSI (Ant0/1) Tx Power(PUSCH) SINR(Ant0/1) CQI Rank Index UL/DL RB Num (Avg.) PDSCH/PUSCH Thp DL/UL MAC Thp.. Following parameters are shown during VoLTE measurement. Rx Delay Rx Jitter Rx Packet Loss
Page 47
XCAL-Auto Mobile User Guide
RF Information (Qualcomm Chipset)
LTE Cell
RTP Info
LTE Cell screen shows Set, EARFCN, PCI, RSRP, RSRQ, and Cell
VoLTE Summary screen shows Rx Packet Loss, Rx RTP Throughput,
Graph. Colors of Set and Graph line are the same.
Rx Delay, Rx Delta Delay, Rx Jitter, One Way Delay, RTP Packet
LTE Cell is available depending on device type.
Count, and Round Trip Time. RTP Info is available on VoLTE call running.
Set
Rx Packet Loss Rate
EARFCN
Rx RTP Throughput
PCI
Rx Delay
RSRP
Rx Jitter
RSRQ
Rx Inter-arrival time difference Rx Inter-arrival jitter One Way Delay Rx/Tx RTP Packet Count
RTT Tap RSRP, RSRQ button to show RSRP and RSRQ of Cell Measurement. Default is set to RSRP. Tap RSRQ button to initiate graph.
© Copyright by Accuver APAC Ltd.
One Way Delay Inter arrival Jitter Lost Packet Number (cumulative)
Page 48
XCAL-Auto Mobile User Guide
C
Configuring Logmask
onfiguring Logmask
Before you begin measurement project, you are able to define log codes to collect and monitor. By selecting necessary log codes for each technology, you may save time for creating logging file and performance capacity. Log codes list varies depending on chipset type.
© Copyright by Accuver APAC Ltd.
Page 49
XCAL-Auto Mobile User Guide
Configuring Logmask
Configuring Logmask Setting In Logmask Setting screen, select technology tab at the top of the screen and select the check boxes of log codes to collect and monitor.
1. Tap Menu - Log Mask Setting button.
© Copyright by Accuver APAC Ltd.
2. Logmask Option Setting screen appears. Tap a technology tab to configure log codes at the top of the screen.
3. Tap + button to expand log code list for the technology.
4. Select the checkboxes of log codes to measure and tap Apply & Save button. Or, Tap Recommend button to select recommended log codes.
Page 50
XCAL-Auto Mobile User Guide
P
Performing AutoCall Test
erforming AutoCall Test
XCAL-Mobile generates and terminates voice and data calls automatically. Configures and edits AutoCall scenario (for Single/Multiple call test). Starts AutoCall test. Terminates AutoCall test.
© Copyright by Accuver APAC Ltd.
Page 51
XCAL-Auto Mobile User Guide
Performing AutoCall Test
Creating AutoCall Scenario (For Single Call Test) Before you start AutoCall test, you need to pre-configure AutoCall scenario (script). AutoCall scenario can be configured and edited in smart phone. For Single call AutoCall test, XCAL-Mobile processes AutoCall test call by call. It supports call types of Voice, FTP, Web, Ping, and VoLTE.
1. In main screen of XCAL-Mobile, tap Menu tab.
2. Tap AutoCall Settings. Or, tap Add/Edit button next to scenario combo box of Main screen to move to AutoCall Scenario creation screen directly.
© Copyright by Accuver APAC Ltd.
3. Tap a call type.
5. Enter a call name in Call Name entry field.
4. Get Scenario: Downloads created AutoCall Scenario from FTP server to XCALMobile. See Downloading AutoCall Scenario.
Page 52
XCAL-Auto Mobile User Guide
1. Configure AutoCall scenario.
Performing AutoCall Test
2. Tap Save button.
3. A new AutoCall scenario is created successfully.
4. Tap Call Name combo box, and you may find the created scenario in the list.
For detail of how to configure AutoCall scenario for each call type, see Appendix: Configuring AutoCall Scenario.
To edit existing scenario, open a scenario configuration screen, edit setting, and tap Save To create more scenarios, tap New
© Copyright by Accuver APAC Ltd.
button.
button.
Page 53
XCAL-Auto Mobile User Guide
Performing AutoCall Test
Creating AutoCall Scenario (For Multiple Call Test) Before you start AutoCall test, you need to pre-configure AutoCall scenario (script). AutoCall scenario can be configured and edited in smart phone. XCAL-Mobile processes AutoCall test for multiple calls sequentially (Multi-Call) supporting all call types. AutoCall test for multiple calls applies the AutoCall scenarios pre-configured for single call tests.
For details of how to configure AutoCall scenario for single call test, see Creating AutoCall Scenario (For Single Call Test).
© Copyright by Accuver APAC Ltd.
Page 54
XCAL-Auto Mobile User Guide
Performing AutoCall Test
AutoCall Test for Sequential Multiple Calls (Multi-Call) XCAL-Mobile processes AutoCall test for multiple call types sequantially.
1. In main screen of XCAL-Mobile, tap Menu tab.
2. Tap AutoCall Settings. Or, tap Add/Edit button next to scenario combo box of Main screen to move to AutoCall Scenario creation screen directly.
© Copyright by Accuver APAC Ltd.
3. Tap Multi-Call.
4. Tap scenario combo box to select scenarios sequentially, and the selected call scenarios are listed. 5. Tap checkboxes of the selected call scenarios to include and process multi call test.
Page 55
XCAL-Auto Mobile User Guide
6. Configure Repeat Count of call test. Create logging file for each scenario: Select the checkbox if you want to create logging file (*.drm) for respective AutoCall scenario.
© Copyright by Accuver APAC Ltd.
Performing AutoCall Test
7. Tap Save button to save test options. 8. Tap Start button to start Multi-Call test.
9. Multi-Call test is started moving to Call Stat. tab, and shows test status in table and graph.
11. Tap AUTOCALL STOP button to terminate the test while measurement.
10. Tap the graph at the bottom of the screen, and shows status data in table. Tap the table to show data in graph vice versa.
Page 56
XCAL-Auto Mobile User Guide
Performing AutoCall Test
Importing AutoCall Scenario Created AutoCall scenario can be downloaded from ftp server to XCAL-Mobile. Name of AutoCall Scenario file in FTP should be AutoCallScenarioAlias.ini or AutoCallScenarioSet.ini.
1. Tap Menu – AutoCall Settings button.
© Copyright by Accuver APAC Ltd.
2. Tap Get Scenario button in AutoCall Settings screen.
3. GET SCENARIO screen appears. Configure ftp server information to download AutoCall scenario.
4. Tap Get button.
Page 57
XCAL-Auto Mobile User Guide
Performing AutoCall Test
Starting AutoCall Test (In Classic tab) You may start AutoCall test by tapping Start button in Main tab, and AutoCall test is started based on configured AutoCall scenario.
1. Tap Main tab.
2. Swipe left and right on Call Type section to select a call type to test.
4. Tap Start button to start AutoCall.
5. AutoCall test starts.
3. And tap Scenario Name combo box to select a call scenario.
© Copyright by Accuver APAC Ltd.
Page 58
XCAL-Auto Mobile User Guide
6. Main screen moves to Call Stat. tab, and shows test status in table and graph.
© Copyright by Accuver APAC Ltd.
Performing AutoCall Test
7. Tap the graph at the bottom of the screen, and shows status data in table. 8. Tap the table to show data in graph vice versa.
9. During measurement, tap Map button to display measurement data and serving line graphically in Google map in real-time. For details, see Monitoring in Digital Map.
10. When automated call test is automatically terminated based on pre-configured call script, Result History screen appears. For details, see Call Result History.
Page 59
XCAL-Auto Mobile User Guide
Performing AutoCall Test
Starting AutoCall Test (In All Scenarios tab) You may start AutoCall test by tapping Start button in Main tab, and AutoCall test is started based on configured AutoCall scenario.
1. Tap Main tab.
© Copyright by Accuver APAC Ltd.
2. Tap All Scenarios tab.
3. Select a pre-configured AutoCall scenario, and tap START button to start AutoCall.
4. AutoCall test starts.
Page 60
XCAL-Auto Mobile User Guide
5. Main screen moves to Call Stat. tab, and shows test status in table and graph.
Performing AutoCall Test
6. Tap the graph at the bottom of the screen, and shows status data in table. 7. Tap the table to show data in graph vice versa.
© Copyright by Accuver APAC Ltd.
8. During measurement, tap Map button to display measurement data and serving line graphically in Google map in real-time. For details, see Monitoring in Digital Map.
9. When automated call test is automatically terminated based on pre-configured call script, Result History screen appears. For details, see Call Result History.
Page 61
XCAL-Auto Mobile User Guide
Performing AutoCall Test
Terminating AutoCall Test XCAL-Mobile normally terminates an AutoCall test automatically when it runs through the whole course of the AutoCall scenario (script). However, it can be also be terminated by tapping AUTOCALL STOP button during AutoCall measurement. When it is terminated, Result History screen appears. Tap one of AutoCall tests, its details are shown. For detail, see Call Result History.
1. AutoCall test is terminated automatically.
© Copyright by Accuver APAC Ltd.
2. Or, you can terminate AutoCall test while measurement.(Auto Call Stop Button)
Page 62
XCAL-Auto Mobile User Guide
M
Monitoring in Digital Map
onitoring in Digital Map
Measurement data and serving lines are visualized in digital map in real-time during measurement. Internal GPS of smart phone is used for location information, and if you import BTS/Repeater data, map displays their information. Digital map supports two map types; image map and satellite map. The speed at which digital map displays greatly depends on the internet access speed of the handset itself. 3G coverage area shows faster update than that of 2G coverage area. XCAL-Mobile basically support Google map for monitoring data in smart phone screen. If you want to use Baidu map, select Baidu map option from Map Options – Settings. For details, see Configuring Map Options – Settings.
Displays data in digital map. Configures map options. Configuring Map Options - Parameters Configuring Map Options - Settings. Imports BTS/Repeater Data
© Copyright by Accuver APAC Ltd.
Page 63
XCAL-Auto Mobile User Guide
Monitoring in Digital Map
Displaying Data in Digital Map XCAL-Mobile enables you to see measurement data and serving lines in Google map.
1. In main screen of XCAL-Mobile, tap Map tab.
© Copyright by Accuver APAC Ltd.
: Marks current location in green color in digital map.
: Shows satellite
2. Tap Menu button on smart phone hardware to open Setting window.
: Shows image map.
Page 64
XCAL-Auto Mobile User Guide
Monitoring in Digital Map
Configuring Map Options XCAL-Mobile enables you to change map setting in Google map. To open Map Options, tap Menu button on smart phone hardware. Items
Description
BTS On/Off
Shows/Hides BTS in map.
RPT On/Off
Shows/Hides Repeater in map.
Legend On/Off Parameter
Shows/Hides legend in map. Selects parameters of technologies to display in map. For details, see Configuring Map Options – Parameters.
Clear Call Event On/Off Settings
Clears data in map. Shows/Hides call events in map. Configures symbol size, update time interval, minimum distance for data update, user location, BTS/RPT size, serving line width, and importing BTS data from FTP/local disk. For details, see Configuring Map Options – Settings.
Route On/Off Capture
© Copyright by Accuver APAC Ltd.
Shows/Hides Route in map. Captures current screen.
Page 65
XCAL-Auto Mobile User Guide
Monitoring in Digital Map
Configuring Map Options – Parameters Parameters button in Map Options menu selects parameters of technologies to display in map. Tap Parameters button, and Parameters pop-up screen appears. Select technology and corresponding parameter you want to display on the map. Items Common LTE
© Copyright by Accuver APAC Ltd.
Description App. DL Thp, APP. UL Thp, Network Type RSSI, RSRP, RSRQ, SINR
Page 66
XCAL-Auto Mobile User Guide
Monitoring in Digital Map
Configuring Map Options – Settings Settings button in Map Options menu configures symbol size, update time interval, minimum distance for data update, user location, BTS/RPT size, serving line width, and importing BTS data from FTP server or local disk. Items
Description
Symbol Size
Configures symbol size that is currently displayed in the map.
Update Time
Configures time to update to the map. (unit: sec)
Min. Distance
Configures minimum distance to move to update to the map. (unit: meter)
Auto Focus
Places user location at the center of map when the current location is out of the map.
Offline Map
Loads and displays mobile local disc map when data connection (3G, WiFi, LTE, etc.) is unavailable.
Baidu Map
Shows Baidu map from China.
BTS/RPT Size
Configures BTS/Repeater size.
Line Width Size
Configures serving line width.
BTS Update From FTP
Imports BTS data from FTP server or Local Disk. Tap BTS Update From FTP Server / Local
Server / Local Disk
disk button, and configure FTP server / Local Disk information where BTS data file is saved. BTS data file should be in *.ini format. For details, see Importing BTS/Repeater Data. Some FTP server requires Passive Mode on.
BTS/RPT Clear
© Copyright by Accuver APAC Ltd.
Clear stored BTS/RTS data in map
Page 67
XCAL-Auto Mobile User Guide
Monitoring in Digital Map
Importing BTS/Repeater Data Existing BTS/Repeater data file in FTP server or smart phone local disc can be imported to XCAL-Mobile.
[File Name Format] BTS File: name of technology.ini Repeater File: name of technology_R.ini
© Copyright by Accuver APAC Ltd.
Page 68
XCAL-Auto Mobile User Guide
1. In main screen of XCAL-Mobile, tap Map tab.
Monitoring in Digital Map
2. Tap Menu button on smart phone hardware to open Setting window.
3. BTS Update From FTP Server: Imports existing BTS/RPT data file from designated FTP server. 4. BTS Update From Local Disk: Imports existing BTS/RPT data file from smart phone local disc.
© Copyright by Accuver APAC Ltd.
Page 69
XCAL-Auto Mobile User Guide
[BTS Update from FTP Server] a. Tap BTS Update from FTP Server button. BTS DB Server Settings screen appears.
© Copyright by Accuver APAC Ltd.
Monitoring in Digital Map
b. Configure FTP information, and tap BTS Update or Repeater Update button.
c. XCAL-Mobile application connects to the configured FTP server and Server Connected pop-up message appears.
e. Tap Yes button.
d. Tap to select *.ini file to import from DB file list.
Page 70
XCAL-Auto Mobile User Guide
f.
Make sure DB Updated pop-up message is displayed.
© Copyright by Accuver APAC Ltd.
Monitoring in Digital Map
g. Tap Save button to load imported BTS/RPT data file to map.
h. Imported BTS/RPT data is displayed in map.
Page 71
XCAL-Auto Mobile User Guide
Monitoring in Digital Map
[BTS Update from Local Disk]
c. Cell site DB Update screen appears.
a. Tap BTS Update from Local Disk button. BTS Update From Local Disk screen appears.
d. Tap to select *.ini file to import from DB file list.
e. Tab Yes button.
f.
The selected BTS/RPT file is imported to XCAL-Mobile with the pop-up message of DB Updated
b. Tap BTS/Repeater Update button.
© Copyright by Accuver APAC Ltd.
Page 72
XCAL-Auto Mobile User Guide
C
Call Result History
all Result History
XCAL-Mobile provides a list of AutoCall test you have completed and its details. The list of AutoCall test result (Result History) is shown from; Result History list after terminating AutoCall test Call Result History in Menu tab
© Copyright by Accuver APAC Ltd.
Page 73
XCAL-Auto Mobile User Guide
1. In main screen of XCAL-Mobile, tap Menu tab.
3. Result History list appears.
2. Tap Call Result History.
3G
, WiFi
Call Result History
, LTE
© Copyright by Accuver APAC Ltd.
4. Tap one of AutoCall tests, and XCALMobile shows its details.
5. Only FTP, Throughput Info appears when tapping test result in Detail Info.
icons in Result History list shows each call test has been performed in 3G or WiFi or LTE environment.
Page 74
XCAL-Auto Mobile User Guide
U
Uploading Log File
ploading Log File
XCAL-Mobile enables you to upload test logging file to a designated FTP server.
When AutoCall test is completed, log files are generated in *.drm and *.csv format as a pair. Logging files in *.csv format help to see results of measurement data on smart phone itself. Logging files are saved in XCAL-Mobile/Logging folder.
© Copyright by Accuver APAC Ltd.
Page 75
XCAL-Auto Mobile User Guide
1. In main screen of XCAL-Mobile.
Uploading Log File
2. Tap Menu tab. And Tap Log Upload button.
3. Do you want to turn Wi-Fi on? Pop-up screen is shown.
5. A list of logging files is shown.
4. Log Upload function is only available when WiFi is on.
© Copyright by Accuver APAC Ltd.
Page 76
XCAL-Auto Mobile User Guide
6. User can upload checked logging files to a designated FTP Server.
Uploading Log File
: Select all logging files. : Unselect all selected files. : Delete selected files.
When tapping Upload button without configuring Upload setting at the topright of the screen, Not Found Server address is popped up at the bottom of the screen.
7. FTP server configuration screen appears.
: Configure FTP Server. For details, see Uploading Setting.
© Copyright by Accuver APAC Ltd.
Page 77
XCAL-Auto Mobile User Guide
8. Configure FTP server to upload logging files. 9. Tap Save button. 10. Tap Back button
© Copyright by Accuver APAC Ltd.
Uploading Log File
11. Tap Upload button. 12. Progress bar is shown.
13. When uploading process is finished, Upload End (Complete) 100% message is shown. Tap the screen to return the previous screen.
If you stop while uploading, End by User message is shown and uploading process is stopped.
Page 78
XCAL-Auto Mobile User Guide
Uploading Log File
Uploading Setting XCAL-Mobile enables you to configure uploading options in Upload Server screen.
1. Tap Set button in Log Upload screen.
2. Upload Server (FTP) screen appears. 3. Configure FTP options; FTP server address, Port number, user ID/PW, Server Path.
4. DRM Auto Upload: Uploads log file in *.drm format onto FTP server automatically when AutoCall test is terminated.
6. Tap Save button at the upper right side of Upload Server (FTP) screen to complete configuration. 7. Completion pop-up message appears at the bottom of the screen.
5. E-Mail Notification: Automatically sends message to the configured e-mail address when uploading is completed.
© Copyright by Accuver APAC Ltd.
Page 79
XCAL-Auto Mobile User Guide
A
Uploading Log File
dditional Function
XCAL-Mobile provides you with further functions. Manual Logging Replay Screen Capture About (License Return, Help) Other Settings (Naming Log File, CSV Delimiter, RAT & Band Lock, External GPS,TTS Alarm, Split log file)
© Copyright by Accuver APAC Ltd.
Page 80
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
Manual Logging Basically, XCAL-Mobile automatically generates and saves logging file after AutoCall test. It also allows you to manually generate and save logging file, which includes monitoring signal and packets coming from smart phone, without AutoCall test. If AutoCall test is started during manual logging, XCAL-Mobile stops generating manual logging file, and starts generating AutoCall logging file. XCAL-Mobile gives first priority on AutoCall logging file.
1. Tap Menu button on smart phone hardware to pop Manual Logging function. Tap Logging start button.
© Copyright by Accuver APAC Ltd.
2. When Manual Logging function is on, manual logging running icon is displayed at the upper left corner of screen.
3. Tap Menu button on smart phone hardware. Tap Logging Stop button to stop manual logging.
4. Manual Logging drm file will be generated on Log Upload Screen.
Page 81
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
Manual Logging function runs in background mode. You can use other smart phone features while running Manual Logging function of XCALMobile in background mode.
1. When Manual Logging function is on, manual logging running icon is displayed at the upper left corner of screen.
© Copyright by Accuver APAC Ltd.
2. Tap Back button on smart phone hardware to terminate XCALMobile application. For detail, see Terminating XCALMobile.
3. A confirmation pop-up screen appears. Tap Yes button.
4. XCAL-Mobile application is terminated, and Manual Logging function runs in background mode.
Page 82
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
Replay Replay function replays existing logging file. RF information of smart phone will be displayed. Logging files in *drm format are available for Replay function.
1. Tap Menu button on smart phone hardware to pop Replay function. Tap Replay button.
© Copyright by Accuver APAC Ltd.
2. Tap Add button.
3. A list of logging files is shown. Tap one of logging file to replay.
4. Information of selected logging file is displayed. 5. Tap Click to Replay button.
Page 83
XCAL-Auto Mobile User Guide
6. Replay status is shown in percentage at the top of Replay screen.
Chapter 11. Additional Function
8. User can set the Replay speed using top of Screen. (1x, 2x, 3x)
7. Replay is completed showing replay status of 100% at the top of Replay screen.
© Copyright by Accuver APAC Ltd.
Page 84
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
Screen Capture For the easier troubleshooting purpose, Screen Capture function captures the current screen and report message to Accuver along with the captured screen image.
1. Tap Menu button on smart phone hardware, and tap Screen Capture button.
© Copyright by Accuver APAC Ltd.
2. Captured image files are listed. Select captured image you want to report error. Tap Send button.
3. My Info Setting screen appears. Configure your information, and tap Send to Accuver button.
4. Error is reported via email successfully.
Page 85
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
About About screen checks registration status, returns the currently used XCAL-Mobile License, and opens Quick Guide. About screen shows license type, expiration date, supportable technology, chipset, supportable AutoCall types, and functions.
1. Tap Menu button on smart phone hardware to pop About function. Tap About button.
© Copyright by Accuver APAC Ltd.
2. About screen shows Device Type, License Type, License date information, chipset, supportable AutoCall type, technologies, and functions.
3. To return the currently registered and using license, tap Return the License button at the bottom of the screen.
4. Tap Return the License button, and confirmation screen pops up. Tap Yes button to return License.
Page 86
XCAL-Auto Mobile User Guide
5. To delete the currently registered and using license, tap Delete the License in Mobile button at the bottom of the screen.
Chapter 11. Additional Function
6. Tap Delete the License in Mobile button and confirmation screen pops up. Tap Yes button to return License.
7. To open Quick Guide file, tap Show the Quick Guide button in About screen.
9. Quick Guide and User Guide of XCAL-Mobile is opening. Swipe up and down the screen to read.
8. To open User Guide file, tap Show the User Guide button in About screen.
10. To close tap Back button on smart phone hardware.
Quick Guide and User Guide are not opened during AutoCall test.
© Copyright by Accuver APAC Ltd.
Page 87
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
Other Settings Options screen enables you to configure extra options for program starting up operation, logging file, and etc. To open Options screen, tap Menu – Other Settings button. Configure options, and tap Save button to save setting. Items Startup
Description Configures options related to the program start-up. Screen Always on: Literally, XCAL-Mobile screen is always on. Auto Start: Executes XCAL-Mobile program when powering on the smart phone device. Auto Logging: Starts Manual Logging when executing XCAL-Mobile application. Manual logging in Background mode: Runs manual logging in background mode. Manual logging is processed while using other smart phone applications. Manual logging is started when selecting Menu – Logging Start.
Logging
Configures options related to logging file. Packet Capture: Save IP Packet Capture data using PCAP function Save to DRM File: Includes packet capture data to the current logging file (*.drm file). Save to PCAP File: Saves packet capture data to another file (*.pcap file) separately. IP Frame (to DRM): Adds IP data using DM interface to the current logging file (*.drm file) : Configures packet length of IP Frame. For SIP and RTP of VoLTE, configure as 1,500. When it is configured as 1,500 for high throughput testing, it may cause loss of DM data. : When it is checked, air plane ON/Off runs automatically. This icon is recommended for mobiles with Qualcomm chipset. : Configures for some special devices such as Galaxy Note2.
© Copyright by Accuver APAC Ltd.
Page 88
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
(Continue) Items Logging
Description XCAL Format: Includes Timestamp data to existing log codes. Real Time Compress: Compresses logging file (*.drm -> *.drx) Path: Designates logging file save path. Naming Log File: Enables you to configure name of log file before/after AutoCall. For details, see Other Settings – Naming Log File. Naming Log File (Before AutoCall): Configures log file name before starting AutoCall. Naming Log File (After AutoCall): Configures log file name when AutoCall test is completed. Confirm Start Autocall: Pop-up screen appears, when AutoCall starts. CSV Delimiter (Current: Tab): For details, see Other Settings - CSV Delimiter.
Phone Set Mode
Configures network mode of smart phone device. Network (RAT/Band) Lock (DM): Tap Set button to configure technology, band, and UARFCN/ARFCN of WCDMA/GSM using NV Read/Write functions. Network type varies depending on License key type. It is supported by Galaxy S2 LTE and Galaxy S4 LTE. RAT/Band Lock (Hidden): For Galaxy S3 (GT-I9305)/Galaxy Note2 (GT-N7105) only. Configure data network and band for test. For details, see Other Settings – RAT & Band Lock.
Logcat
Logcat Logging: Logging the log information output by Android OS and applications. Logcat Filter: Filtering the specific log messages. Set the Logcat command, Timestamp, Alternate log buffer and Filter-spec. Save Logcat files (Separately): Save Logcat files separately.
© Copyright by Accuver APAC Ltd.
Page 89
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
(Continue) Items GPS
Description Ext.GPS: Connects external GPS for location information. For details, see Other Settings – External GPS. Internal GPS: Network GPS:
TTS Alarm
TTS Alarm Message: When the GPS status or DM status is abnormal, then voice alarm or pop-up message will appear. It is divided into two categories, System and Transition. System Voice Alarm is on when GPS and DM status are abnormal, Transition Voice Alarm is on when LTE-PCI status is abnormal.
Split log file
Adjust log file size by user-set time or size. Per Time: Split log file per time. Per Size: Split log file per size.
© Copyright by Accuver APAC Ltd.
Page 90
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
Other Settings - Naming Log File XCAL-Mobile application is designed to save log file automatically when AutoCall or Manual Logging test is completed. With Naming Log File option, you may configure name of log file in *.drm format. You can configure before or after AutoCall or Manual Logging test.
1. Tap Menu – Other Settings. 2. Tap the checkbox for Naming Log File (Before/After AutoCall).
© Copyright by Accuver APAC Ltd.
3. Naming Log File (Before AutoCall): Configures name of log file (*. drm) before starting AutoCall or Manual Logging test.
4. Naming Log File (After AutoCall): Configures name of log file (*.drm) after completing AutoCall or Manual Logging test.
5. Log file is saved with the user pre-configured log file name.
Page 91
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
Other Settings - CSV Delimiter XCAL-Mobile application is designed to create paired log files in *drm and *csv format when AutoCall or Manual Logging test is completed. With CSV Delimiter option, you may configure delimiter in *.csv file between comma and tab. Default is set to comma.
1. Tap Menu – Other Settings. 2. Default is set to Comma.
© Copyright by Accuver APAC Ltd.
3. Tap the checkbox for CSV Delimiter to change delimiter to Tab.
Examples of *.csv files with delimiter of Comma and Tab.
Page 92
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
Other Settings – Network (RAT/Band) Lock (DM) RAT & Band Lock function enables the device to select Radio Access network and bands which user wants to set using NV Read/Write function. After setting the RAT or bands, user needs to reboot the device manually. Support Mobile: Galaxy S2 LTE and Galaxy S4 LTE
1. Tap Menu – Other Settings. 2. Tap to select SET button for Network(RAT/Band) Lock(DM)
© Copyright by Accuver APAC Ltd.
3. SET button for RAT Lock shows RAT Lock screen. 3-1. Tap to select the checkboxes of technologies, and tap SET button.
4. SET button for Band Lock (Hidden) shows Band Lock screen. Tap Conversion icon at the right side of Band Lock to converse to RAT Lock screen, and vice versa.
4-1. Tap Check button for the Radio Access technology to be selected and tap OK button. 4.2 Tap to select checkboxes of bands, and tap OK button.
Page 93
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
Other Settings - RAT & Band Lock (Hidden) RAT & Band Lock function enables you to configure data network and band for test. Proper firmware is need for RAT & Band Lock function. Support Mobile: Galaxy Note2 (GT-N7105), Galaxy S3 (SGH-I747M/GT-I9305T/SGH-I747/GT-I9305), Galaxy S4.
1. Tap Menu – Other Settings. 2. Tap to select SET button for RAT Lock (hidden) or Band Lock (Hidden).
© Copyright by Accuver APAC Ltd.
3. SET button for RAT Lock shows RAT Lock screen. 3-1. Tap to select the checkboxes of technologies, and tap SET button.
4. SET button for Band Lock (Hidden) shows Band Lock screen. Tap Conversion icon at the right side of Band Lock to converse to RAT Lock screen, and vice versa.
4-1. Tap + button to unfold technology band. 4-2. Tap to select checkboxes of bands, and tap SET button.
Page 94
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
Other Settings - External GPS In order to minimize errors during measurement test, external GPS can be connected through Bluetooth function and used for XCAL-Mobile.
1. Tap Menu – Other Settings. 2. Tap the checkbox for Ext.GPS.
© Copyright by Accuver APAC Ltd.
3. When Bluetooth function is not activated, Bluetooth permission request pop-up screen appears. Tap Yes button.
4. Make sure Bluetooth enabled pop-up message appears. 5. Tap Scan for Device button to list up paired Bluetooth.
6. Green dot at the right top corner of the screen means external GPS is connected properly. 7. Red dot means external GPS is not connected. 8. Column of GPS Information in RF Information screen displays External GPS.
Page 95
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
Other Settings – TTS Alarm In order to detect abnormal status of device during measurement test, TTS Alarm function is used. When the GPS status or DM status is abnormal, then voice alarm or pop-up message will appear.
1. Tap Menu – Other Settings. 2. Tap to select SET button for TTS Alarm Manager.
© Copyright by Accuver APAC Ltd.
3. Set button for Voice Alarm Setting.
4. Tap to select the checkboxes of TTS or Toast function, and tap Save button.
Page 96
XCAL-Auto Mobile User Guide
Chapter 11. Additional Function
Other Settings – Split log file Split log file function divides a log file into time and size unit.
1. Tap Menu – Other Settings.
© Copyright by Accuver APAC Ltd.
2. Per time: split log file per time. Configure time as user desired time.
3. Per size: split log file per size. Configure size as user desired size.
4. Check creation of several log files as 10MB unit.
Page 97
XCAL-Auto Mobile User Guide
M
Master/Slave Test
aster/Slave Test
XCAL-Mobile builds Master/Slave test feature to measure several Slave test mobiles simultaneously under the control of one Master mobile. Test mobiles can perform measurement test as a master or slave mobiles by configuring in XCAL-Mobile application. Up to three slave mobiles can be controlled by one master mobile. Slave mobiles are available for in-building test.
Master/Slave feature runs for authorized license key users only. For authorized license key, contact to Accuver Support. Master/Slave function is supported for smart phone models in Android OS version greater than 4.0 (Ice cream sandwich). Some Master mobile models may be unable to connect more than 2 Slave mobiles due to Bluetooth function. It is recommended to use smart phones manufactured by Samsung Electronics. Configures for Master or Slave mobile in XCAL-Mobile application. Starts M/S test under the control of one master mobile.
© Copyright by Accuver APAC Ltd.
Page 98
XCAL-Auto Mobile User Guide
Master/Slave Test
Configuring Master or Slave Mobile In XCAL-Mobile application, you can define the test mobile as master or slave side. Master and Slave mobiles are to be configured in parallel. Following procedure instructs how to define the test mobile as master or slave and assign AutoCall scenario for master and slave mobiles respectively. Up to three slave mobiles can be assigned for one master mobile.
1. Tap Menu button on smart phone hardware, and tap M/S button.
© Copyright by Accuver APAC Ltd.
2. Select Master or Slave. 3. To configure the test mobile as a master mobile, tap Master. To configure the test mobile as a slave mobile, tap Slave.
4. Tap Master or Slave icon ( / ) in the status icon bar at the upper right corner of the screen to switch mode.
Master-1. In Master side, tap Bluetooth Search button to connect Slave mobile to Master mobile.
Page 99
XCAL-Auto Mobile User Guide
Slave-1. In Slave side, tap Connect to Device button.
Master/Slave Test
Slave-2. Bluetooth Connect pop-up screen appears. Slave-3. Select a MAC address of Master to connect from the list. Bluetooth Connect pop-up screen disappears automatically.
© Copyright by Accuver APAC Ltd.
Slave-4. Connection to master mobile is completed.
Master-2. (In Master side) When Slave mobile is connected to Master mobile properly, connection status is showed as Connected. MAC address of Slave mobile is displayed for respective Device ID.
Page 100
XCAL-Auto Mobile User Guide
Master-3. When three Slave mobiles are connected to Master mobile properly, the status icon displays three small LEDs in MS icon. Number of LEDs in MS icon in the status icon stands for number of Slave mobiles connected to Master mobile.
© Copyright by Accuver APAC Ltd.
Master/Slave Test
Master-4. Tap Master Scenario Set or Scenario Set button to assign AutoCall scenario for master and slave mobile. Master-5. Choose a Scenario pop-up screen appears. Select an AutoCall scenario.
5. Master Scenario Set: Assigns AutoCall scenario of master mobile. 6. Scenario Set: Assigns AutoCall scenario of respective slave mobile. Pre-configured AutoCall scenarios are listed in Choose a Scenario screen. For details of how to configure a new AutoCall scenario, see Creating AutoCall Scenario.
Page 101
XCAL-Auto Mobile User Guide
Master/Slave Test
Starting M/S Test You completed configuration of master/slave mode for the smart phone installed XCAL-Mobile application and assignment of AutoCall scenario for master and slave mobiles respectively. Master/Slave function enables you to start AutoCall test for all connected master and slave mobiles at the same time.
1. Make sure type and name of AutoCall scenario is properly assigned for master and slave mobile.
© Copyright by Accuver APAC Ltd.
2. Slave mobile displays details of the selected AutoCall scenario in the screen.
3. In Master mobile, tap AutoCall Start button to start AutoCall test for master and slave mobile at the same time. Master and slave mobile start AutoCall test.
4. To terminate AutoCall test, tap Menu button on smart phone hardware, M/S button, and AutoCall Stop button in order.
Page 102
XCAL-Auto Mobile User Guide
Master/Slave Test
Inbuilding Test of Master/Slave Mobiles Master/Slave mobiles are able to perform inbuilding test supporting both Moving and Fixed point modes. Master and Salve mobiles save the same inbuilding measurement options. When inbuilding test options are configured in Master mobile, they are configured in Slave mobile automatically. Inbuilding configurations and test processes are the same of normal XCAL-Mobile application. For details of Inbuilding test, see Inbuilding test.
1. Make sure Master and Slave configuration is completed properly.
© Copyright by Accuver APAC Ltd.
2. Tap Inbuilding Start button in Master mobile. Configure Inbuilding test options.
3. Start inbuilding test in Master mobile, Slave mobiles are started in the same condition automatically.
4. When inbuilding test is completed, tap Done button in Master mobile. Inbuilding tests in Slave mobiles are terminated automatically.
Page 103
XCAL-Auto Mobile User Guide
I
Inbuilding Test
nbuilding Test
XCAL-Mobile enables you to perform measurement inside of a building. Configures Inbuilding test. Starts Inbuilding test. Moving Point: Performs call test while moving inside of a building. Fixed Point: Performs call test at a certain measurement point inside of a building.
© Copyright by Accuver APAC Ltd.
Page 104
XCAL-Auto Mobile User Guide
Inbuilding Test
Configuring Inbuilding Test Before starting Inbuilding test, configure Inbuilding test.
1. In main screen of XCAL-Mobile, tap Menu tab.
© Copyright by Accuver APAC Ltd.
2. Tap Inbuilding.
3. Inbuilding List screen appears. Tap Add button.
4. Inbuilding Setting screen appears. Enter a building name in Building entry field.
Page 105
XCAL-Auto Mobile User Guide
5. Tap Floor button, and swipe up and down to select floors.
© Copyright by Accuver APAC Ltd.
Inbuilding Test
6. Tap Upper/Under button. The left section designates ground floors and above ground floors. The right section numbers starting with B designates basement floors.
7. Swipe up and down to select floors and Tap Done button.
8. Select a measurement type between Moving and Fixed. Moving: Performs call test while moving inside of a building. For detail, see Moving Point Test. Fixed: Performs call test at a certain measurement point inside of a building. For detail, see Fixed Point Test.
Page 106
XCAL-Auto Mobile User Guide
9. Tap Get GPS button to configure current GPS information (or enter longitude and latitude data in Lon and Lat entry field). Address1 will automatically be filled up with address of current location as it is suggested by Google Map Search.
Inbuilding Test
10. Enter an Address in Address 2 entry field.
12. Inbuilding – Fixed/Moving Screen appears.
11. Tap Save button to save Inbuilding configuration, and tap START button.
Some mobile requires tapping Get GPS button several times due to network condition.
© Copyright by Accuver APAC Ltd.
Page 107
XCAL-Auto Mobile User Guide
Inbuilding Test
Starting Inbuilding Test Indoor measurements can be accommodated in with AutoCall feature. After completing configuration of Inbuilding test, you may start Inbuilding test. Following procedure instructs how to start Inbuilding test.
1. In main screen of XCAL-Mobile, tap Menu tab.
© Copyright by Accuver APAC Ltd.
2. Tap Inbuilding.
3. Select a building name.
4. Tap START button to start Inbuilding test.
Page 108
XCAL-Auto Mobile User Guide
Inbuilding Test
Moving Point Test By selecting Moving type for Inbuilding, XCAL-Mobile will perform measurements while moving among points inside of a building. The following procedure describes the process to follow after tapping the START button to start Inbuilding test.
1. Tap START button to start Inbuilding test.
© Copyright by Accuver APAC Ltd.
2. Inbuilding – Moving screen appears.
3. Tap the combo box for Call Name to select call scenario.
4. Select floor.
Page 109
XCAL-Auto Mobile User Guide
5. Select building image file. Select Image: Selects existing image file inside of smart phone.
Inbuilding Test
6. Selected image file is shown.
7. Pinch open and out to zoom in and out of the image.
8. Tap a starting point on the image (floor map) to perform AutoCall test, and tap Yes to confirm this point is starting point.
Take Photo: Takes photo.
© Copyright by Accuver APAC Ltd.
Page 110
XCAL-Auto Mobile User Guide
9. XCAL-Mobile is ready to start Inbuilding test (with AutoCall), and Start button is activated. Tap Start button, AutoCall test will begin. Move to the second point.
© Copyright by Accuver APAC Ltd.
Inbuilding Test
10. Inbuilding test is started, and its status is displayed at the lower left side of screen. Call measurement screen is shown for a few seconds and will return to Inbuilding image screen.
11. When you are arriving at the second point, tap the second point on image. Tap Yes button to confirm.
12. Configured parameters are shown on the image.
Page 111
XCAL-Auto Mobile User Guide
13. Tap the third point.
Inbuilding Test
14. Then, start to move to the third point. Continue the same processes for following points.
© Copyright by Accuver APAC Ltd.
15. Tap Menu button on smart phone hardware to activate settings.
16. Tap Legend Off button to hide legend in the image.
Page 112
XCAL-Auto Mobile User Guide
17. Tap Parameters button to open parameters setting screen. Parameters are categorized by Common, LTE, 3G, 2G, CDMA, and EVDO.
© Copyright by Accuver APAC Ltd.
Inbuilding Test
18. Configure parameter.
19. Selected parameter is shown in image.
20. Tap Settings button to configure Update Time to apply parameter values.
Page 113
XCAL-Auto Mobile User Guide
21. Tap Done button to terminate test.
Inbuilding Test
22. When AutoCall is finished based on scenario, call test is automatically terminated. 23. Inbuilding test is completed, and Clear button is activated. To remove points, tap Clear button.
When Inbuilding test starts, Done button is activated. Selecting Done button will terminate/stop AutoCall test and Inbuilding test which is running.
© Copyright by Accuver APAC Ltd.
Page 114
XCAL-Auto Mobile User Guide
Inbuilding Test
Fixed Point Test By selecting Fixed XCAL-Mobile will perform measurements at a measurement point location inside of a building. The following procedure describes the process beginning with the START button to start the Inbuilding measurements:
1. Tap START button to start Inbuilding test, and Inbuilding – Fixed screen appears.
2. Tap the combo box for Call Name to select call scenario.
3. Select building image file. Select Image: Selects existing image file inside of smart phone. Take Photo: Takes photo.
© Copyright by Accuver APAC Ltd.
4. Selected image file is shown. Select a certain point on image to measure, and tap Yes button to confirm the selected point is at the correct location.
Page 115
XCAL-Auto Mobile User Guide
5. XCAL-Mobile is ready to start Inbuilding test, and Start button is activated. Tap Start button.
© Copyright by Accuver APAC Ltd.
Inbuilding Test
6. Inbuilding test for Fixed type is started.
7. When AutoCall is finished based on scenario, call test is terminated automatically. Or, to stop call test manually, tap DONE button.
8. Inbuilding test at a fixed point is terminated, and Clear button is activated. To perform more tests at fixed points, tap Clear button, and repeat steps 4 - 8.
Page 116
XCAL-Auto Mobile User Guide
Inbuilding Test
Configuring Inbuilding Options XCAL-Mobile enables you to change Inbuilding map setting in Inbuilding screen. To open Inbuilding Options, tap Menu button on smart phone hardware. Items Legend On/Off Parameter
Description Shows/Hides legend in map. Selects parameters of technologies to display in Inbuilding. For details, see Configuring Inbuilding Options – Parameters.
© Copyright by Accuver APAC Ltd.
Settings
Configures data update time in Inbuilding screen.
Capture
Screen Capture
Page 117
XCAL-Auto Mobile User Guide
Inbuilding Test
Configuring Inbuilding Options – Parameters Parameters button in Inbuilding Options menu selects parameters of technologies to display in Inbuilding. Tap Parameters button, and Parameters pop-up screen appears. Select technology and corresponding parameter you want to display on the Inbuilding. Items Common
Description App. DL Throughput /APP. UL Throughput Network Type
LTE
RSSI / RSRP RSRQ /SINR
© Copyright by Accuver APAC Ltd.
Page 118
XCAL-Auto Mobile User Guide
T
Terminating XCAL-Mobile
erminating XCAL-Mobile
When you have completed all necessary measurement test with XCAL-Mobile or you want to terminate the application while measurement, you can terminate the application. During AutoCall test, XCAL-Mobile application cannot be terminated. Stop AutoCall test first by tapping AUTOCALL STOP button in AutoCall test screen, and terminate the application. For details of how to terminate AutoCall test, see Terminating AutoCall Test. Press Home button on smart phone hardware, and XCAL-Mobile application runs in background mode
© Copyright by Accuver APAC Ltd.
Page 119
XCAL-Auto Mobile User Guide
1. When you want to terminate XCAL-Mobile application, tap Back button on smart phone hardware.
© Copyright by Accuver APAC Ltd.
Terminating XCAL-Mobile
2. Exit configuration pop-up screen appears. Tap Yes button.
3. XCAL-Mobile application is terminated.
Page 120
XCAL-Auto Mobile User Guide
T
Troubleshooting
roubleshooting
While using XCAL-Mobile, the program pops up a troubleshooting alarm screen when the program is terminated compulsively or by anonymous errors and launched again. You may report error to Accuver Technical Support team directly. Error report is sent to Technical Support team via an e-mail automatically.
© Copyright by Accuver APAC Ltd.
Page 121
XCAL-Auto Mobile User Guide
1. When you execute XCAL-Mobile after the program has been terminated compulsively or by anonymous errors, an alarm screen pops up.
Troubleshooting
2. Tap Send Error Report button to report error to Accuver Technical Support team.
3. My Info Setting screen appears. Configure user information.
4. Tap Send to Accuver button to report the error via an e-mail automatically.
Don’t Send: Ignores the alarm screen, and do not show the alarm screen again. Later: Shows the alarm screen next time you execute XCALMobile.
© Copyright by Accuver APAC Ltd.
Page 122
XCAL-Auto Mobile User Guide
R
Related Products
elated Products
XCAL-Mobile is compatible with Accuver’s other server-based solution series below.
is an autonomous total measurement and monitoring solution with web-based centralized management. Simply by installing XCAL-Auto in any vehicles, XCAL-Auto automatically collects data over the air and its central server controls remote-units and status information.
is a web-based total integrated platform that post-processes log files and provides engineers with a high level KPI and call failure view of the network via web client access. It also supports automatic reporting, automatic diagnostics of call failures, data export, download of log files, and etc.
© Copyright by Accuver APAC Ltd.
Page 123
XCAL-Auto Mobile User Guide
A
Appendix : Configuring AutoCall Scenario
ppendix: Configuring AutoCall Scenario
XCAL-Mobile supports the following AutoCall types; Voice, FPT, Web, Ping, VoLTE and Multi Call.
© Copyright by Accuver APAC Ltd.
Page 124
XCAL-Auto Mobile User Guide
Appendix: Configuring AutoCall Scenario
Time Configuration (Voice, Web, Ping, VoLTE) Following displays items commonly configured for voice call tests.
Enter a call name in the entry field.
Enter a call name in the entry field. Maximum time period to sustain connection calls Number of call attempts to repeat
Maximum time to setup radio link connection Time period to wait to start a new call after ending a call
© Copyright by Accuver APAC Ltd.
Page 125
XCAL-Auto Mobile User Guide
Appendix: Configuring AutoCall Scenario
Time Configuration (FTP) Followings displays items commonly configured for data call tests.
Enter a call name in the entry field. Enter a call name in the entry field. Time to complete task. . Number of call attempts to repeat.
Time period to log in FTP Server Maximum time to setup network connection for a call. (Time Period to connect to data service) Time period to wait to start a new call after ending a call. (Time Period to change Flight Mode)
None: Idle – T.Setup(Log in) - Traffic Airplane Mode: Idle (Airplane ON) – Setup (Airplane Off) – T.Setup(Log in) – Traffic Wi-Fi Mode: Idle – Setup (Wi-Fi ON) – T.Setup(Log in) – Traffic
© Copyright by Accuver APAC Ltd.
Page 126
XCAL-Auto Mobile User Guide
Appendix: Configuring AutoCall Scenario
Configuration for Each Call Type Followings are configuration options for each call type.
Voice
FTP Voice Type: 1)Ori : Call Send Test 2)Ter : Call Receive Test 3)Con : Continuous Call Test (Traffic Time unlimited) Dial Number: Phone Number
When tapping HW Menu button and tapping Speaker On button, you can use speakerphone function while processing Voice AutoCall test. For details of MOS Setting in Voice, see MOS Setting configuration.
© Copyright by Accuver APAC Ltd.
FTP: Down: Download data Up: Upload data Passive Mode: FTP Server Option FTP IP Address: Targeting URL FTP User ID: FTP Server Setting FTP Password: FTP Server Setting FTP Server Path: FTP Folder Full Name Setting(Down/Up) FTP File Name: Name of the original file to be downloaded from server (For Download test) Kilo(k) & Mega(m) Unit Support: ex) 100k, 230k, 2m, 10m, … (For Upload test) Upload File Delete: Removes upload file every time test is terminated. Pending: If select Pending ON 1)Interval: Set max time limitation that allows pending conditions 2)Threshold: Set data throughput limitation that allows pending conditions
Page 127
XCAL-Auto Mobile User Guide
Appendix: Configuring AutoCall Scenario
Web
VoLTE Web Type: 1)Browsing : Web Browsing Test 2)HTTP Download : Web Downloading Test 3)HTTP Upload : Web Uploading Test Default Time out: Web Test End Event Delay Option(Default : 2 second) URL: Input scenario name and URL address in entry field
Voice Type: 1)Ori : Call Send Test 2)Ter : Call Receive Test 3)Con : Continuous Call Test in Origination (Traffic Time unlimited) Dial Number : Phone Number RTP TIMEOUT: Drop is pegged when none of RTP packets are received during the RTP TIMEOUT(second) set by user PickUp Delay PickUp Count
Ping Destination: Input IP address or URL of ping test destination Count: Input ICMP request count TTL: Input Time To Live (1 – 255) Packet size: Input size of data bytes to be transmitted Interval: Input ICMP request interval (second unit) Success Rate: Test Success Setting Value > Fail Rate Test Fail Setting Value < Fail Rate Fail Rate=[(Ping Count – Proceeded Count) + Fail of Proceeded count] / Ping Count
© Copyright by Accuver APAC Ltd.
Page 128
XCAL-Auto Mobile User Guide
Appendix: Configuring AutoCall Scenario
Multi Call Multi Call enables you to perform test based
on
multiple
call
scenarios
sequentially. 1. Tap scenario combo box to select scenarios sequentially, and the selected call scenarios are listed. 2. Tap to select checkboxes of call scenario you want to include and process multi call. 3. Configure Repeat Count of call test. Create logging file for each scenario: Select the checkbox if you want to create logging file (*.drm) for respective AutoCall scenario. 4. Tap Save button. 5. Tap Start button to start automated Multi Call test. For
detail
of
how
to
configure
test
options of Multi-Call, see AutoCall Test for Sequential Multiple Calls (Multi-Call).
© Copyright by Accuver APAC Ltd.
Page 129
XCAL-Auto Mobile User Guide
A
Appendix : Call Events
ppendix: Call Events
XCAL-Mobile provides test result with call events by call types depending on AutoCall types.
© Copyright by Accuver APAC Ltd.
Page 130
XCAL-Auto Mobile User Guide
Appendix : Call Events
Voice
Web
Events Setup Fail
Description Setup fail occurs when radio link setup failure happens.
Drop
Call drop during progress of traffic
Idle
* CDMA : Fail to receive general page message * WCDMA : Fail to receive rrc Connection Request
Events
Description
Traffic Fail
Traffic fail is declared if connection to application layer fails after finishing PPP layer connection.
Page Connect Fail Pending
message
Page Connect Fail is declared when a wrong web site address is configured. If throughput is sustained under predefined threshold for designated time threshold, then pending is declared and the call will be dropped.
FTP
Time Out
If download or upload from/to application cannot be finished during predefined traffic time interval, Time Out
Events
Description
Traffic Fail
Traffic fail is declared if connection to application layer fails after finishing PPP layer connection. *This event is available for data service such as FTP, TFTP
is declared. Error
Number of calls with various errors such as No ATDT, modem Error and port error. These errors are related to test phone.
and HTTP Pending
If throughput is sustained under predefined threshold for designated time threshold, then pending is declared and the call will be dropped *This event is available for FTP
Time Out
If download or upload from/to application cannot be finished during predefined traffic time interval, Time Out is declared. *This parameter is available for FTP
© Copyright by Accuver APAC Ltd.
Page 131
XCAL-Auto Mobile User Guide
Appendix: Call Events
Ping
VoLTE
Events
Description
Events
Fail
Fail is declared when wrong IP and URL are configured.
Setup Fail
Error
Description Setup
Fail
is
declared
when
API
message:
Traffic fail is declared depending on the success Ratio.
CallEstablished is not received until Setup Time is
Number of calls with various errors such as No ATDT,
completed.
modem Error and port error. These errors are related to test phone.
© Copyright by Accuver APAC Ltd.
Drop
Drop is declared when API Call Ended is received between Traffic Start and Traffic Time ends
Page 132
XCAL-Auto Mobile User Guide
A
Appendix : Parameter Description
ppendix: Parameter Description
Detailed descriptions of parameters for each technology are listed.
© Copyright by Accuver APAC Ltd.
Page 133
XCAL-Auto Mobile User Guide
Appendix: Parameter Description
LTE Parameter RSSI Tx power PCI(Serving) RSRP(Serving) RSRQ(Serving) SINR(Ant0/Ant1) CQI(CW0/CW1) Rank Index UL Power Headroom RB Num Avg. (DL/UL) MCS(DL/UL)
Description
Parameter
Received Signal Strength indication measured Transmitted power of the device
Traffic State
Reference Signal Received Power for the serving cell(dBm) Reference
Signal
Received
Quality
for
the
Wideband PMI
Signal to Interference and Noise ratio for the serving cell(dB) Channel Quality Indicator of CW0 and CW1
Mobile Network Code
EARFCN(DL/UL) Bandwidth(DL/UL) Band Indicator Tracking Area Code
use in addition to the power being used by
Cell ID(Serving)
and UL Modulation Index and Percentages of Modulation schemes assigned(QPSK/16QAM/64QAM) Block Error Rate for PDSCH channel (%)
PUSCH BLER
Block Error Rate for PUSCH channel (%)
PDSCH Throughput
Throughput measured in PDSCH channel(Kbps)
PUSCH Throughput
Throughput measured in PUSCH channel(Kbps)
Wideband Precoding Matrix Indicator
MNC
How much transmission power left for a UE to
Average Resource Block number assigned in DL
Current traffic status of device Mobile Country Code
Rank Indicator
current transmission.
Downlink path loss computed in the device
MCC
serving cell(dB)
PDSCH BLER
MAC Throughput
(DL/UL) Path Loss
Physical Cell Identity of the serving cell
Description
Allowed Access EMM State EMM Substate Transmission Mode (DL/UL) Num of Antenna(Tx/Rx)
Channel
number
and
Frequency(MHz)
the
device is selecting Bandwidth assigned(MHz) Band Indicator in LTE Tracking Area Code which the current eNB belongs to E-UTRAN Cell Identifier for the serving cell Allowed Access on the cell based on network select mode Indicated by NAS Current EPS Mobility Management State Current EPS Mobility Management Substate Transmission mode in DL and UL Number of antenna being used currently
Throughput measured in MAC layer.
© Copyright by Accuver APAC Ltd.
Page 134
XCAL-Auto Mobile User Guide
A
Appendix : RTP Analysis in VoLTE
ppendix: RTP Analysis in VoLTE
Audio and Video stream are sent through RTP protocol.
© Copyright by Accuver APAC Ltd.
Page 135
XCAL-Auto Mobile User Guide
Appendix: RTP Analysis in VoLTE
The following items will be calculated by decoding RTP packets and calculating the methods mentioned. They will calculate every packet received and display every second in XCAL-Mobile. Parameter Rx Delay
Description Time difference of RTP timestamps from previous RTP packet and current RTP packet Rx Delay = R(i) – R(i-1)
Inter Arrival time Difference
It is the time difference in relative transit time expressed as D(i, j) = {R(i) – R(i-1)} – {S(j) – S(i-1)} Here, S(j) is the RTP timestamp from packet j sent and R(i) is the RTP timestamp from packet i received
Inter-Arrival Jitter
It is calculated over packets that arrived consecutively as follows. If J(i) represents the Inter-Arrival Jitter for packet, i and D (i – 1, i) represents Inter-Arrival Time Difference between consecutive packets, i – 1 and i, then Inter-Arrival Jitter is calculated as,
Jitter value for the first packet is considered zero. It is calculated at every packet and averaged over one second. Loss Packet Packet Loss Rate
The number of packets lost. RTP Sequence Number helps detect packet losses. It is calculated as,
. It is calculated at every second. RTP Throughput
Over DL, the throughput is measured as,
It is calculated at every second.
© Copyright by Accuver APAC Ltd.
Page 136
© Copyright by Accuver Co., Ltd.