Up dated 10/6/11 4:12 A10/P10LT.
REQUIREMENTS NO. A. I.
II.
B.
LIFE SAVING APPLIANCES
EQUIPMENT COMMUNICATIONS RADIO LIFE SAVING APPLIANCE (SLS Cons 2001, Ch.IV.) 1. Two Way VHF Radiotelephone Radiotelephone Apparatus (SLS Cons 2001, Ch.IV, Ch.IV, Part C, Reg.7.1. & 7.2. 2. Search And Rescue Radar Transponder (SART) 9 GHZ. (SLS Cons 2001, Ch.IV, Part C, Reg.7.3.) 3. Emergency Position Indicating and Radio Beacon (EPIRB) 406 Mhz. (SLS Cons 2001, Ch.IV, Part C, Reg.7.1.6., & 8.3.) DISTRESS FLARES 1. Rock Rocket et Para Parach chut utee Fla Flare ress (SL (SLS S Con Conss 2001 2001,, Ch. Ch.II III, I, Part Part B, Reg. Reg.6. 6.3. 3.))
2. Red Hand Flare 3. Smoke Signal PERS PERSON ONAL AL LIFE LIFE SAVI SAVING NG APPL APPLIA IANC NCES ES (SLS Cons 2001, Ch.III, Reg.1.) 1. Life Buoy (SLS Cons 2001, Ch.III, Reg.1.)
2. Life Life Jack Jacket et (SLS (SLS Cons Cons 2001 2001,, Ch. Ch.II III, I, Reg. Reg.1. 1.3, 3, Reg. Reg.2 2 & Reg. Reg.3. 3.))
C.
3. Immersion Suits dan Thermal Protective Aids (SLS Cons 2001, Ch.III, Reg. 4.) MUST MUSTER ER LIS LIST T AND AND EMER EMERGE GENC NCY Y INST INSTRU RUCT CTIO IONS NS (SLS Cons 2001, Ch.III, Part B, Reg.8.)
FOR
REQUIREMENTS
REMARKS
3 Unit 2 Unit 2 Unit 1 Unit I Unit
Kapal dengan ukuran GT. 500 atau lebih Kapal dengan ukuran GT. 300 s/d GT. 500 Kapal dengan ukuran GT. 500 atau lebih Kapal dengan ukuran GT. 300 s/d GT. 500
12 Pcs Pcs (Min (Minim imal al)) utk utk Kapa Kapal, l, 4 Pcs Pcs unt untuk uk Sekoci / Rescue boat 6 Pcs utk Sekoci / Rescue boat 2 Pcs untuk Sekoci / Rescue Boat 8 Pcs , LOA < 60 meter 12 Pcs , LOA 60 s/d 120 meter 18 Pcs , 120 s/d 180 meter Juml Jumlah ah Pela Pelaya yarr + 10 10 % untu untuk k ana anakk-an anak ak Tidak perlu
Tergantung penempatan
D. E.
LINE LINE THRO THROW WING ING APPL APPLIA IANC NCES ES (SLS Cons 2001, Ch.III, Part B, Reg.18.) SURVIVAL CRAFT (SLS Cons 2001, Ch.III, Part B, Reg.11.)
F. G. H.
I NF NFL AT AT AB AB LE LE L IF IFE RA RAFT (SLS Cons 2001, Ch.III, Part B, Reg.26.2.) HYDR HYDROS O STA TATI TIC C REL RELEA EASE SE UNIT UNITS S (SLS Cons 2001, Ch.III, Part B, Reg.20.9.) RESCUE BOAT (SLS Cons 2001, Ch.III, Part B, Reg.21.2.)
I.
TANGGA EMERGENCY (SLS Cons 2001, Ch.III, Part B, Reg.11.7. & Reg.23.1.) (SLS Con Conss 200 2001, 1, Ch. Ch.II III, I, Par Partt B, Reg. Reg.37 37.) .) LAMP LAMPU U EMBA EMBARK RKAS ASII / DEBA DEBARK RKAS ASII (SLS
J.
PASSANGER AND CARGO SHIPS
4 Unit Jumlah pelayar Jumlah pelayar Jumlah ILR 2 Unit 1 Unit
Kapal dengan ukuran GT. 500 atau lebih
Diletakkan di Anjungan
- Dilengkapi Tali (30m), minimal 2 set. - Dilengkapi lampu (holmes light), minimal ½ jumlah keseluruhan L/B - Dilengkapi 2 (dua) ‘Self Activating Smoke Signal With Light’ (MOB). Masi Masing ng-m -mas asin ing g dil dilen engk gkap apii Lam Lampu pu dan dan Pel Pelui uit. t. Dite Ditemp mpat atka kan n di di Rua Ruang ng penumpang, di kabin Crew, di anjungan dan di Ruang control mesin. Tidak perlu - Muster list hrs ditempatkan di anjungan, ECR, dan Crew Accomodation Space. - Instruksi-instruksi Instruksi-instruksi darurat untuk penumpang juga harus ada, seperti : dimana Muster station berada, petunjuk/instruksi yg hrs dikerjakan penumpang bila keadaan darurat, instruksi cara menggunakan Life Jacket, dll. Tali dan rocket jadi satu paket. Diletakkan di Anjungan. 30 % dari jumlah pelayar dilambung kiri dan 30 % di lambung kanan. Sisanya yg 40 % diisi / dilengkapi dilengkapi oleh oleh ILR. Tergantung Capasitas sekoci penolong, sisanya dimuat di ILR. Tergantung Jumlah ILR GT. 500 keatas. GT. 500 kebawah.
Minimal 2 Unit
Minimal Satu Unit setiap sisi kapal
Mamp Mampu u Mene Menera rang ngii den denga gan n jela jelass
Dite Ditemp mpat atka kan n di di dek dekat at sek sekoc oci, i, ILR ILR,, dan dan di di dek dekat at tang tangga ga dar darur urat at
Up dated 10/6/11 4:12 A10/P10LT.
REQUIREMENTS NO. A. I. II.
FIRE FIGHTING
ARRANGEMENT FOR
EQUIPMENT FIRE EXTINGUISHERS PERMANEN FIRE EXTINGUISHERS (SLS Cons 2001, Ch.II-2, Part A, Reg.5, Reg.8, Reg.9, Reg.10.) PORTABLE FIRE EXTINGUISHERS (SLS Cons 2001, Ch.II-2, Part A. Reg.6.) 1. Foam Fire Extinguishers. Capasitas antara 9 liter s/d 13,5 liter. (SLS Cons 2001, Ch.II-2, Part A. Reg.6.4.) 2. Dry Chemical Fire Extinguishers 3. CO2 Fire Extinguishers
PASSANGER AND CARGO SHIPS
REQUIREMENTS
Tidak dirinci jumlahnya Tidak dirinci jumlahnya Tidak dirinci jumlahnya
B.
C. D.
FIREMAN’S OUTFIT (SLS Cons 2001, Ch.II-2, Part A, Reg.17.) 1. Baju Tahan Api dan perlengkapannya (Baju, celana, sepatu, sarung tangan, helmet, safety lamp, dan Kapak. (SLS Cons 2001, Ch.II-2, Part A, Reg.17.1.1.) 2. Breathing Apparatus dan perlengkapannya (smoke mask, regulator, selang karet, tabung Oksigen berkapasitas 1200 liter. (SLS Cons 2001, Ch.II-2, Part A, Reg.17.1.2.) 3. Tabung Oksigen minimal mempunyai kapasitas 1200 ltr. 4. Tali penyelamat (Safety line). (SLS Cons 2001, Ch.II-2, Part A, Reg.17.2.) INTERNATIONAL SHORE CONNECTION FIRE HYDRANT (SLS Cons 2001, Ch.II-2, Part A, Reg.4.6.)
- Satu diantaranya, harus ditempatkan didekat pintu masuk ruang tersebut. - GT.1000 atau lebih, minimal memiliki 5 Pcs Portable fire Extinguisher. - Bila dilengkapi Boiler, satu ruangan minimal harus mempunyai pemadam busa dengan kapasitas 135 liter.
2 Sets
---
2 Sets
---
2 Cylinder Tergantung jumlah BA sets 1 ( Satu ) set Jumlah tidak dirinci. Disetiap kompartemen harus ada Jumlah minimal sama dengan Fire Hydrant
F.
FIRE HOSE (SELANG PEMADAM KEBAKARAN)(SLS Cons 2001, Ch.II-2, Part A, Reg.4.7.) NOZZLE (SLS Cons 2001, Ch.II-2, Part A, Reg.4.8.)
G.
KOTAK SOPEP (MARPOL 73/78 Cons 2002, Annex I, Ch.IV, Reg.26.)
H. I.
LAMPU EMERGENCY (LAMPU DARURAT) (SLS Cons 2001, Ch.II-1, Part D, Reg.41 & Reg.42.) GENERAL ALARM (SLS Cons 2001, Ch.II-2, Part A, Reg.12.)
Jumlah tidak dirinci
J. K.
HEAT DETECTOR ( SLS Cons 2001, Ch.II-2, Part A, Reg.12.3.3.) SMOKE DETECTOR (SLS Cons 2001, Ch.II-2, Part A, Reg.12.3.2.)
Jumlah tidak dirinci Jumlah tidak dirinci
L. M.
WATER SPRINKLER (SLS Cons 2001, Ch.II-2, Part A, Reg.12.2.1, Reg.12.3, Reg.12.6) O IL & WAT ER SE PARAT OR (MARPOL Cons 2002, Annex I, Ch.II, Reg.9 (7).)
Jumlah tidak dirinci
E.
REMARKS
Jumlah tidak dirinci
Untuk cadangan BA sets Panjang tali tidak disebutkan GT. 500 atau lebih, minimal memiliki satu set Jarak antar hydrant : Mampu dicapai oleh Nozzle tipe Jet. Coupling yang terpasang harus sejenis dengan fire hydrant. Ditempatkan secara berkelompok dalam bagian yang terpisah, tiap kelompok tidak lebih dari 200 buah. Harus terbuat dari bahan anti karat dan dapat bekerja pada suhu antara 68 C hingga 79 C. Isinya : Neos, pasir, serbuk gergaji, sepon busa, sapu lidi, serok, ember, majun, dan kek kayu. D i e me rg en cy st ati on, ru ang p enum pan g, ga ng -ga ng , anjungan, dan di kamar mesin. Mampu menjangkau seluruh ruangan. Control panel berada di anjungan dan di ‘fire control panel’ Di dapur, dan di kompartemen mesin Di anjungan, ECR, kompartemen penumpang dan ABK. Di Car deck ˚
1 (satu) Pc J um la h ti da k d ir inc i
˚