LEGEND
GENERAL NOTES:
2. 3.
4.
ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS, THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE RULES AND REGULATIONS OF THE LOCAL ENFORCING AUTHORITY, AND THE REQUIREMENTS OF THE LOCAL POWER. THE ELECTRICAL WORKS SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER. THE ELECTRIC SERVICE VOLTAGE SHALL BE SINGLE PHASE 3-WIRE WITH GROUND 230V 60HZ.
THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF INCOMING POWER FOR CONNECTION INCLUDING THE LOCATION OF METER CENTER.
6.
ALL PIPE SLEEVES SHALL BE PROVIDED WITH PROPER SUPPORT OR ANCHORAGE NECESSARY FOR PERMANENT CONNECTION WITH CONCRETE WALLING OR BEAM. ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES, PANELBOARDS, LIGHTING FIXTURES AND ALL NON-CURRENT CARRYING METAL PARTS SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE.
7.
8. 9. 10.
11. 12.
13.
SINGLE POLE SWITCH
1-40w FLUORESCENT LAMP
S2bc / S2
2-GANG SWITCH ELECTRICAL SERVICE ENTRANCE
LIGHTING FIXTURE M 01
PP
THE ELECTRICAL WIRING INSTALLATION SHALL BE DONE IN INTERMEDIATE METALLIC CONDUIT (IMC) ELECTRICAL METALLIC CONDUIT (EMT). FLEXIBLE METALLIC CONDUITS SHALL ALSO BE USED WHERE REQUIRED. MINIMUM SIZE FOR ALL CONDUITS SHALL BE 15mm INSIDE DIAMETER ELECTRICAL TRADE SIZE MINIMUM SIZE OF PULLBOX TO BE USED SHALL BE 150x150x100mm. ALL WIRES FOR INDOOR INSTALLATION SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE THWN/THHN UNLESS OTHERWISE INDICATED. THE
5.
Sa / S
KWHM
KILOWATT-HOUR METER
BRANCH CIRCUIT HOMERUN
ACU OUTLET
DUPLEX CONVENIENCE OUTLET
LIGHTING LINE, CONCEALED ON CLNG.
E.RANGE OUTLET
POWER LN., EMBEDDED ON SLAB/WALL
REFRIGERATOR OUTLET
TELEPHONE OUTLET
WEATHERPROOF OUTLET
CABLE TV OUTLET
ABOVE COUNTER OUTLET
PANEL BOARD
PP,LP,PB
ALL 20-AMPERE CIRCUIT HOMERUNS TO PANELBOARDS OF MORE THAN 30 METERS IN 2 LENGTH SHALL BE 5.5mm UNLESS OTHERWISE SPECIFIED CONDUIT ROUTING SHOWN IS ESSENTIALLY DIAGRAMMATICAL. CONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE COORDINATION REQUIREMENTS OF UTILITIES & OTHER TRADES.
PANEL
1.
CHANDELIER
ANY DISCREPANCY IN LOCATION AND RATINGS OF EQUIPMENT AND APPARATUS SHALL BE VERIFIED WITH THE ENGINEER/OWNER OR ANY OF HIS REPRESENTATIVES AND CHANGES SHALL BE MADE ACCORDINGLY. ALL MATERIALS TO BE USED AND EQUIPMENT TO BE INSTALLED SHALL BE NEW AND MUST BE OF THE APPROVED TYPE FOR THE PARTICULAR LOCATION AND PURPOSE INTENDED.
S1
S1
S2
ALL CONDUITS AND RACEWAY PENETRATIONS THROUGH FIRE OR SMOKE RATED WALLS AND FLOORS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAME AND HOT GASSES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC OF FIRE STOPS ASTM-E-814. PROVIDE A UL LISTED THROUGH PENETRATION FIRE STOP SYSTEM NUMBERED PER UL FIRE RESISTANCE DIRECTORY.
S2 S2
MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS: SWITCHES : 1,370MM ABOVE FLOOR FINISH RECEPTACLES : 300MM ABOVE FLOOR FINISH : 170MM ABOVE COUNTER TOP PANEL BOARD : 1800MM ABOVE FLOOR FINISH
150
1 E-1
PROJECT & LOCATION
POWER & AUXILIARY LAYOUT SCALE:
1:100 MTS.
OWNER
SHEET CONTENTS
SHT NUMBER
ALL PLANS AND SPECIFICATIONS, AS INSTRUMENTS
GENERAL NOTES
OF SERVICE, ARE THE PROPERTY OF THE DESIGNER
ENGINEER
AND CANNOT BE COPIED OR DUPLICATED IN PART OR IN WHOLE WITHOUT WRITTEN PERMISSION,THIS MUST HAVE TO BE RETURNED WHEN NO LONGER IN USE.