Technical Data Sheet
9 1/2" OnTrak II
Directional Sensor Vibration, Stick-Slip
35.1 ft (10.7 m)
For reservoir navigation applications, the OnTrak MPR sensors provide eight multi-depth resistivity measurements enabling optimum well placement. Two gamma ray detectors mounted on opposite sides of the tool provide an indication of approaching bed boundaries and can be used to provide an image of the wellbore. The annular pressure reading enables fast reaction to wellbore stability issues and monitoring of the dynamics behavior of the BHA (with stick-slip and vibrations) allows the optimization of drilling parameters and improvements in reliability. Service Benefits Real time Reservoir Navigation and accurate well placement Geological confirmation of bed boundaries with azimuthal gamma ray Fast two-way communication between surface and downhole saves time Optimum directional control due to sensors closer to the bit Fewer well control issues and improved reliability Fully modular system allows the complete integration of high end LWD services (SoundTrak™, LithoTrak™, CoPilot®, TesTrak™) ® Excellent log quality when used with AutoTrak G3.0 applications at high ROP High frequency phase resistivity measurements for superior vertical resolution and improved definition of thin beds and fluid contacts Low frequency attenuation resistivity measurements for increased depth of investigation gives better estimates of Rt with a greater immunity to environmental effects
© 2006 Baker Hughes Incorporated. All rights reserved. OTK2-20-60-0950-00-A
Stop Sub
12.1 ft (3.7 m) BCPM
OnTrak Sensor Sub - Directional measurements - Multiple propagation resistivity - Azimuthal gamma ray - Gamma ray imaging - Annular and borehole pressure both flow on and flow off - Vibration and stick slip monitoring - Enhanced memory, including a high speed dump capability - Integrated Stabilizer Communication and power module - Regulated complete systems power - Downlink functionality - High speed mud pulse telemetry
2.4 ft (0.7 m)
OnTrak
9 1/2" OnTrak II
Azimuth Gamma Ray
12.5 ft (3.8 m) Annular Pressure 23.0 ft (7.0 m)
9.6 ft (2.9 m)
MPR
5.5 ft (1.6 m)
2.4 ft (0.7 m)
Stop Sub
INTEQ developed the 9 1/2" OnTrak™ II to be a fully integrated MWD/LWD tool, providing real time Directional, Gamma, MPR® resistivity, downhole pressure and vibration measurements from a single sub. The OnTrak tool has been uniquely designed to take into account all the challenges present in the most demanding rotary steerable applications. The OnTrak sensor sub works in conjunction with the AdvantageSM surface system to deliver optimal directional control, precise formation evaluation and data to enable reservoir navigation whilst drilling. This innovative design delivers increased reliability, reduces the number of connections and offers optimized sensor-to-bit distance in a compact BHA (bottom hole assembly). The tool combines an integrated sensor sub with a power and communications module supplying the following capabilities:
17.3 ft (5.3 m)
9 1/2" OnTrak II General Tool Specifications Hole Size Range Nominal Tool OD Length Weight Connections Primary Power Source
Sensor Specifications (continuation) 12 1/4" (31.1 cm) - 26" (66.0 cm) 9 1/2" 23.0 ft (7.0 m) 7,275 lbs (3,300 kg) Up: INTEQ Modular Connection4 Down: INTEQ Modular Connection4 Drilling Fluid driven Turbine
Operating Specifications and Limits Flow Rate Extreme Low Flow Flow Rate Low Flow Flow Rate Standard Flow Rate Moderate High Flow Flow Rate High Flow
Maximum WOB Maximum Tool Rotation Maximum Drilling Torque (at the Bit) Maximum Torque to Failure Maximum Overpull to Failure (w/o Rotation) Maximum Tensile Load Maximum Temperature Operating Survival Maximum Hydrostatic Pressure Maximum Bit Pressure Drop Sand Content Maximum LCM
300 (360*) - 500 gpm 1,140 (1,370*) - 1,870 lpm 430 (515*) - 755 gpm 1,630 (1,955*) - 2,860 gpm 605 (725*) - 1,090 gpm 2,290 (2,750*) - 4,130 lpm 805 (965*) - 1,480 gpm 3,050 (3,660*) - 5,600 lpm 865 (1,040*) - 1,600 gpm 3,280 (3,955*) - 6,050 lpm (*) - min. flow rate for Downlink Operation 505 klbs (2,250 kN) 400 rpm 64,905 ft-lbs (88 kNm) 112,846 ft-lbs (153 kNm) 1,348 klbs (6,000 kN) 1,978 klbs (8,800 kN) 302°F (150°C) 311°F (155°C) 25,000 psi (1,725 bar) No Limitation 1% max. volume, acc. to API 13B (<0.5 % recommended) 40 ppb = 114 kg/m³ (Any pumping of LCM must be carried out according to AutoTrak G3 operations manual)
Maximum DLS for Tool Passage
Maximum RPM Variation Maximum Axial & Lateral Vibration
Standard BHA w/DC With Rotation: 5°/100ft Without Rotation: 9°/100ft Flexible BHA w/CSDP With Rotation: 7°/100ft Without Rotation: 10°/100ft ±80% Maximum deviation from Operating RPM (e.g. 100 RPM: Operating Range=20-180) 5 g RMS (1 - 250 Hz; 1 sec integration) or equivalently 45 g peak (0.025 sec shock pulse duration) (from recorded memory or as flagged by corresponding real-time severity level)
Sensor Specifications Azimuthal Gamma Ray Distance from bottom of tool Sensor Type Measurement Range Accuracy Vertical Resolution
12.5 ft (3.8 m) Scintillation (x2) API GR 0 - 500 API ±2.5 API @ 100 API and ROP = 60 ft/hr (18.3 m/hr) 6" (15.3 cm)
Multiple Propagation Resistivity Distance from bottom of tool 2 MHz Resistivity Phase Difference
5.4 ft (1.6 m) Range: Accuracy:
0.1 - 3,000 ohm-m ±0.85% (0.1 - 50 ohm-m) ±0.4 mmho/m (>50 ohm-m) Range: 0.1 - 500 ohm-m Accuracy: ±1.75% (0.1 - 25 ohm-m) ±0.85 mmho/m (>25 ohm-m) 8" (20 cm) for 90 % response in conductive beds
Attenuation
Vertical Resolution 400 kHz Resistivity Phase Difference
Range: Accuracy:
0.1 - 1,000 ohm-m ±0.85% (0.1 - 25 ohm-m) ±0.8 mmho/m (>25 ohm-m) Range: 0.1 - 200 ohm-m Accuracy: ±4% (0.1 - 10 ohm-m) ±4.0 mmho/m (>10 ohm-m) 12" (30 cm) for 90% response in conductive beds
Attenuation
Vertical Resolution Pressure (Annular, Flow Off Pressure) Distance from bottom of tool Range Accuracy Resolution Directional Distance from bottom of tool Sensor Type
9.6 ft (2.9 m) 0 - 25,000 psi ± 0.25% of full scale 5 psi 17.3 ft (5.3 m) Tri-axial Accelerometer Tri-axial Flux Gate Operator selectable (default: 3°) Resolution Accuracy1 0.09° ±0.1° 0.35° ±1.0°
MTF/GTF switching Measurement Range Inclination 0° - 180° Azimuth2,3 0° - 360° Toolface Magnetic2 0° - 360° Gravity3 0° - 360° Total Magnetic Field 0 - 100,000 nT Dip Angle2 -90° - 90° Vibration, Rotation & Stick-Slip Vibration Distance from bottom of tool Sensor Axial Vibration Type Lateral Vibration Acceleration Range Frequency Range Real-time log options
1.4° 1.4° 35 0.04°
17.3 ft (5.3 m) One Accelerometer, z direction Two Accelerometers, x-y direction 0 - ±15 g 0 - 82 Hz Lateral and Axial vibration; transmitted as severity level Min., Max., Average & Max. lateral and axial vibration in g-RMS and as severity level
Post Run / Memory log options Rotation & Stick-Slip Sensor Type Rotation Speed Real-time log options
Two Axis Magnetometer 0 - ±1,000 RPM (±1 % Accuracy) Downhole RPM, Stick-Slip transmitted as severity level Min., Max., Average RPM, Stick-Slip & Backward Rotation severity
Post Run / Memory log options
1 3
All Sensor accuracies are 2 Sigma confidence Accuracy applies to inclinations greater than 5.0°
±1.5° ±1.5° ±100 ±0.2°
2 4
For a typical magnetic field value at 30° latitude To connect to INTEQ components only
Headquarters INTEQ 2001 Rankin Road Houston, Texas 77073 713-625-4200 www.inteq.com © 2006 Baker Hughes Incorporated. All rights reserved. Although the information contained herein is believed to be accurate, no other representations are made concerning the information. Under no circumstances shall INTEQ be liable for any incorrect or incomplete information. All technical specifications and commercial information concerning the products and/or services described herein may be changed at any time without further notice. Refer to Supplemental Technical Specifications (TDS-20-60-0000-00) for further environmental specific specifications and information on the application, operation, and handling of INTEQ tools.