Home
Add Document
Sign In
Register
JSA #13 -H2S Detector
Home
JSA #13 -H2S Detector
Job safety Analysys...
Author:
arunvrajan2008
111 downloads
397 Views
87KB Size
Report
DOWNLOAD .PDF
Recommend Documents
h2s
h2sDeskripsi lengkap
H2S
H2SDescripción completa
H2S Handbook
h2sDescription complète
H2s Manual
HSEQ FORUMDescription complète
H2S safety
Bulletin for H2S
KERACUNAN H2S
GFull description
Manual H2S
manuel de seguridad de H2SDescripción completa
H2s Manual
HSEQ FORUMFull description
CURSO H2S
EXELENTE MANUAL DE H2S
H2S Ambien.pdf
Deskripsi lengkap
forensik h2s
h2s
H2S Libretto
Libretto of How to Succeed in Business without Really Trying
gas h2s
Full description
H2S Ambien.pdf
Triptico H2S
Triptico H2SDescripción completa
amdal udara H2S
Full description
H2S Contingency Plan
OverviewFull description
ACIDO SULFIDRICO H2S
Descripción completa
H2S Manual - Shell
H2S ManualDescription complète
Hoja de Seguridad h2s
.Descripción completa
Holiday Detector
Manual Holiday Detector
h2s Hand Book[2]
Description complète
KESELAMATAN KRJA H2S
Curso internacional de H2S. Um estudo aprofundado sobre o tema. Excelente e completo.Full description
Metal Detector
Metal Detector
Job Safety Analysis Sheet JOB DESCRIPTION: Functional Testing of H2S Detectors
JSA Ref. No. JSA / KOC / 13
Facility:
Permit No. Date:
Work Area / Equipment:
PERSONAL PROTECTIVE EQUIPMENT & TOOLS: Hard Hat, Safety Shoes, Hand Gloves, Coverall, Portable Radio, Escape Mask SEQUENCE OF BASIC JOB STEPS
POTENTIAL HAZARDS Non – compliance of HSE MS Procedures
Yes / No
PRECAUTIONS
Refer HSEMS Procedure - Doc. No. SA.KOC.004 “Permit to Work”.
Take a Cold Work Permit from Asset Owner.
Ensure test bottle (containing H2S Gas of 10 ppm concentration) & accessories are free from defect & not leaking.
Refer manufacturer instruction for refilling of test gas bottle.
Assess the risk & Override the H2S detector to be function tested.
Do not remove override prior to resetting the alarm in the panel.
Maintain a radio communication between worker at Gas Detector site and the person stationed near F & G panel / Control Room.
Ensure the identity of detector before charging the gas into it.
Defective Tool & Equipment Planning Unintended Shutdown of Facility / Equipment
Lack of Communication
Wrong Identity of Gas Detector
Excessive Charging of H2S to Detector
Apply only the required amount of gas as needed to actuate the detector sensor.
Refer manufactures instruction for functional testing & calibration of detector.
Toxic Gas Leak
Keep the Test Bottle valve closed when not in use.
Do not bring any naked flame or spark generating equipment near the test gas bottle.
Do not dismantle or puncture the test gas bottle even if empty.
Confirm the alarm communication.
Keep the test bottle in safe and secured location.
Do not dispose the empty bottle unsafely.
Refer manufacturer instruction for safe disposal / transportation of empty bottle.
Ensure proper wind up & housekeeping at worksite.
Remove the gas detector override after resetting the alarm in the panel.
Functional Testing Fire & Explosion
Fault Alarm
Unsafe Storage / Disposal of Test Bottle
Windup & Housekeeping
Scattered Material
Additional Hazards (Other than indicated above)
JSA Done By
Name: KOC / ID. No. Controlling Team: Signature:
Designation: Company: Contract No.(If Applicable): Date:
on
gas
charging
through
radio
×
Report "JSA #13 -H2S Detector"
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
×
Sign In
Email
Password
Remember me
Forgot password?
Sign In
Our partners will collect data and use cookies for ad personalization and measurement.
Learn how we and our ad partner Google, collect and use data
.
Agree & close