KONELSAN Elevator Remote Control
Systems
EVO PRO + A3 ELEVATOR REMOTE CONTROL
CARD
www.konelsan.com.tr
LIST OF PARAMETERS 00: LANGUAGE SELECTION (TURKISH/ENGLISH) 01: ELEVATOR TYPE 02: REMOTE CONTROL TYPE 03: NUMBER OF STOPS 04: NUMBER OF BASEMENTS 05: DOOR TYPE 06: BUSY-STATE DURATION 07: LOCK WAITING TIME
08: WAITING TIME ON EACH FLOOR 9: HIGH SPEED DURATION 10: LOW SPEED DURATION 11: DOOR MAXIMUM DURATION 12: PARKING LOT COURSE DURATION 13: PARKING LOT STOP 14: FIRE STOP 15: DIRECTION ARROW FLASH 16: CHANGE PASSWORD 17: CANCEL PASSWORD 18: MAINTENANCE CONDUCTED 19: MAINTENANCE DURATION 20: ERROR LIST 21: DIGITAL ADJUSTMENT 22: DOOR SPECIAL ADJUSTMENT 23: SAVING (ACTIVE/CANCEL) 24: DUBLEX SELECTION 25: CALL TRANSFER 26: PHASE PROTECTION (ACTIVE/CANCEL) 27: PTC (ACTIVE/CANCEL) 28: CABINET SERIAL CARD (ACTIVE/CANCEL) 29: AUTOMATIC DOOR OPENING DURATION
www.konelsan.com.tr
TECHNICAL SPECIFICATIONS:
Sizes Lenght * Width * Height (mm) Operation temperature Protection class Moisture Network Control Entries Control Supply Voltage Power consumption Security Circuit Voltage Control Signal Entries Control Signal Exits
267 / 201 / 35 •0 - +60 ‚C IP20 <95% 3 x 380V, 50Hz, N 24 • 5 Vdc Max. 400mA 10W, for 24VDC At maximum 230Vac (For Hydraulic elevators, 24Vdc in emergency descending!!!) 24 • 5 Vdc 24 • 5 Vdc Short-Circuit Protected
- 2-line 16-character LCD screen and 4-key keyboard - RS-485 serial communication for group operations - RS-485 serial communication for serial installation connection with the cabinet - Keeping the last 20 errors in memory - Internal door bridging security circuit - Internal phase linear engine protection circuit Internal control entry and exits for two automatic doors
www.konelsan.com.tr
OPENING SCREEN
EVO PRO +A3 SERIAL NO : XXXXX
When the system is energized, on the LCD screen, s creen we call "START UP SCREEN" appears. On this screen, software version and serial number of the card you are using are s hown. After waiting for two seconds, the screen passes on to the screen called "HOME SCREEN".
MAIN SCREEN RECORD WAITING...
D:15 +25.4 V
RECORD WAITING...
D:15 +24.0 V
01981
In the main screen, supply voltage of remote control card (100) and stop number where elevator is located are shown.
If numerator type encoder numerator is selected
REVISION FROM CARD
Revision from Card D:15 +24.0 V
By pressing exit button for 2 seconds, change status of elevator to revision and move through up and down buttons.
www.konelsan.com.tr
GROUP OPERATION SCREEN
Group (AB----) P A D:15 24.0 V
Status of six units of panels are provided on the screen as follows.
A-B-C-D-E-F: Specifies the group identities for remote control panels .
A-a
: Specifies whether remote control panel with connection is
P-A
included in group operation or not. ( If small letter is shown, elevator is out of group) : Specifies the group identity owned by controlling remote control panel
--
: Specifies remote control panels that does not exist or not connected.
『
: Shows the speed of communication.
www.konelsan.com.tr
ENTERING THE MENU 00:Language Selection Turkish
Password ? 00000 Serial.code (ABGFY)
To enter the menu, press the ENTER button for 3 seconds. If any passwords are not specified for entry permit, (00000: start up password), the first parameter on the screen, "LANGUAGE" note will appear. If any other password is specified previously, enter the ri ght password by using UP and DOWN buttons. Then press the "ENTER" button to confirm password. If the password is right, the first parameter will appear on the screen. If it is wrong, the warning on the screen will appear saying "WRONG PASSWORD !! ENTRY MADE" and the card will return to main screen, wrong password entry does not block your card. In order to learn the only true password, you can retrieve t he password by contacting our company.
In order navigate through program parameters, UP and DOWN buttons are used and to change parameter values, ENTER and EXIT buttons are used. After changing parameter value by UP and DOWN buttons, in order to save the change, you can press ENTER button to change a parameter permanently. If you do not want to change, you can turn to previous adjustments by pressing EXIT button.
00: Language Selection Turkish -
By this parameter, language selection is made.
www.konelsan.com.tr
TURKISH: Turkish ENGLISH: English
01: Elevator Type Double Speed
You can adjust the drive type of your elevator by means of this parameter.
-
SINGLE SPEED ELEVATOR: For single-speed elevators, this setting should be selected.
-
DOUBLE SPEED ELEVATOR: For double-speed elevators, this setting should be selected.
-
VVVF WITH ROPE: Stepless geared (asynchronous mechanical) and non-geared (synchronous
mechanical) -
HYDRAULIC: For hydraulic elevators, this setting should be selected.
For elevators, this setting should be selected. Besides, " RECOVERY TYPE" parameter should be adjusted in accordance with system.
02: Remote
You can adjust the remote control type of your elevator by means of this
www.konelsan.com.tr
04: Number of Basements 01
05:Door Type Shock Doors
You can adjust the number of basements with this parameter. If elevator remote control type is done in descend, then for the floor under number of basements, the collection is made in ascend. Note: It is used in remote control types except collecting during descend.
You can adjust open-close signal type for automatic doors by means of this parameter.
-
STROKE DOORS: They are only used in elevators without automatic doors.
-
C.AUTO LIMITED : It is only used in elevators with automated limited cabinet doors.
-
C.AUTO UNLIMITED : It is only used in elevators with automated unlimite d cabinet doors.
-
FULLY AUTO LIMITED : It is only used in elevators with fully automatic limited doors.
-
FULLY AUTO UNLIMITED: It is only used in elevators with fully automatic unlimited doors.
As per EN 81-1/2 standards, automatic door should stay inactive only in states
www.konelsan.com.tr
07: Lock waiting time 8 seconds
-
After receiving door closed signal, the maximum duration to be waited for arrival of lock (140) signal is adjusted with this parameter. [second]
8-30 Seconds
8: Waiting on the Floor Duration
During collecting, you can adjust waiting duration at stop before sending to other record from this parameter. [second]
-3.15Seconds
According to EN81-1 and EN81-2 standards, at least 2 seconds of waiting before moving should be adjusted for manual door elevators, when cabinet arrives at the stop. This parameter should be kept in simple controlled (non-collecting) elevators the same as ƒCABINET LAMP„ time and should be adjusted at least as 2 seconds.
www.konelsan.com.tr
11: Door Max. Duration
If the elevator is not closed at the end of duration adjusted with this parameter,
control
panel will return in out of service state. This function can be canceled if required. [second]
- 15-250 Seconds : It is duration to pass into open door error. 12: Arrival to Park Duration -
0-250 Seconds
13: Fire Stop
-
You can adjust the fire stop with this parameter. When Fire (SIDE) entrance is active, elevator directl y goes to that floor and waits with its doors open. With cancelation of fire signal, the elevator returns to normal operation conditions.
CANCEL: Fire stop is not defined in the system.
1-16: Fire stop is defined in the system.
15: Direction Arrow Flash
-
You can adjust the duration of waiting before going to park stop by means of this parameter. [second]
You can adjust flashing of direction arrow while t he Elevator is in motion, by means of this parameter.
CANCEL: Direction arrows are switched on directly according to movement direction.
ACTIVE: Direction arrows flash according to movement direction.
19: Maintenance Duration
As long as your card is in operation, adjusted value of this paramet er will decrease by 1 points. For instance, if adjusted to 45 days, this parameter will show the value of 15 days after 30 days and 45 days
- 45 -250 days
later the value will be 0. In the event of 0 value for this parameter, movement type of elevator is adjusted by MAINTENANCE DURATION END parameter. [day].
20: Error list
With this parameter, stop names are monitored starting from the last error till the first one, and then option of error deletion appears. All errors are deleted by pressing ENTER button.
21: Digital Adjustment
In order to change stop number, while stop number is flashing, using UP-DOWN buttons, find the stop you want to change to. Then, by pressing ENTER button, enable flashing of digital value. By using UPDOWN buttons again, adjust desired digital value for that stop. After adjusting the value you prefer, press the EXIT button again to exit adjusting. Or to adjust another stop, press ENTER button to enable flashing of stop number and repeat the procedures.
www.konelsan.com.tr
25: Transfer Call
With this parameter, if the elevator is operating and
external calls are connected on a
single panel, this parameter is ACTIVATED, on other conditions, CANCELED.
26: Phase Protection
You can use this parameter to activate phase deficiency and phase order control.
-
CANCEL: Deactivated.
-
ACTIVE: Phase not lined
-
ACTIVE: Phase lined
www.konelsan.com.tr
29: Auto Door Opening Duration
-
With this parameter, duration from the opening of the door to stop is entered.
05-20 Seconds
29: Single Door Full Auto
With this parameter, if elevators with stroke door have only one automatic door, floors with automatic doors is sp ecified.
31: RP Delay
In VVVF systems with rope, main contractor may be demanded to descend with delay. In such conditions, RP relay exit delay is adjusted from this parameter. However, in hydraulics elevators, it is used as engine delay [in milliseconds]
-
00000-25000 Milliseconds
32: Rev. Course of
You can adjust the course of action for lower-upper limit breaker in revision with this parameter.
www.konelsan.com.tr
34: Star Triangle
With this parameter, you can adjust the duration for engine to wait before passing to triangle connection after finishing star connection at the start in hydraulic systems. [seconds] [For hydraulic systems]
- 00000-25000 Milliseconds
35: Engine Valve Duration
-
In hydraulic systems, delay of valves at s tart up can be adjusted from this parameter. [seconds] [For hydraulic systems]
00000-25000 Milliseconds
35: Door Open Leveling In order to activate level renewal, this parameter is used. [For VVVF with Rope and Hydraulic elevators] (Without activating this parameter, floor adjustment within cabinet cannot be conducted)
-
CANCEL: Level renewal canceled.
www.konelsan.com.tr
39: Objective Floor Flash
-
CANCEL: it is canceled ACTIVE : it is activated
40: Display Output
-
When this parameter is active, elevator display will show the floor elevator is heading on each floor change.
With this parameter, Evo Pro remote control card andevo-serial card's display output adjustments are conducted.
7 SEGMENT OUTPUT : Normal GRAY CODE OUTPUT : Gray Code Output BINARY CODE OUTPUT : Gray code output
www.konelsan.com.tr
43: M. Break
Monitoring
-
CANCEL: it is canceled ACTIVE : it is activated
44: Numerator Type
-
If this parameter is active, it is necessary for break monitoring contacts to be connected, in the event of cancellation in machines without gears, errors will not be detected in the event of a3 turning into involuntary state. Therefore, it should not be canceled, if it is canceled, our company is not responsible. NOTE: If you receive break monitoring error, press exit button for 30 seconds.
With this parameter, floor sensor selection of the elevator is conducted.
STANDARD M0 : Standard M0 numerator STANDARD M1 : Standard M0 numerator ML1&ML2 : ML1-ML2 numerator as per a3 standards (for hydraulic) ENCODER : Used in shaft copying as per a3 standards
www.konelsan.com.tr
48: Encoder Divider
With this parameter, it is entered based on speed of elevator, number of pulse and engine speed. EXAMPLE: The value entered for 1ms 1500 speed engine 1024 pulse encoder is 26. If the encoder is connected to regulator, then for 1024 pulse encoder is 1.
-
ENCODER DIVIDER CALCULATION : Engine speed x encoder pulse count / 60 /
elevator speed EXAMPLE: 1000 = ACQUIRED RESULT EXAMPLE: Engine speed:160 X encoder pulse: 2048 =327, 680 … 60 = 5,461 … elevator speed:1000 = 5,461 (entered as 5)
49: Position Reset
51: Regulator
Control card will keep its latest position on its memory even though network electricity is interrupted. However, in certain special situations, a position reset may be demanded after retrieval of elevator electricity. In this case, the elevator will descend until it reached the bottommost floor 817 breaker. When it reaches the bottommost floor, floor numerator is reseted. For instance, in systems with battery recovery units, this parameter can be activated to ensure position reseting.
If this parameter is active, it is necessary for regulator monitoring
www.konelsan.com.tr
55: Long Floor Path
On this screen, it adjusts slowing down distance when elevator moves a floor distance or more.
56: Gon g Sound
It enables or disables gong sound in serial communication.
5. First Installation
If this parameter is active, it allows you to conduct depth detection and floor adjustment inside cabinet. Identification of Depth: The elevator is taken into revision position from depth position. Exit button is pressed for 3 sec. After the elevator starts to move, the button is released. Encoder reseting command appears on LCD screen. And after visiting the bottommost compulsory breaker, it move upwards with learning command. By slowing down in the previous stop of the top floor, it completes the top floor. Then it completes the bottommost floor
EVO PRO+ A3Signs on Remote Control Card: R S L3 N 1 2 L†R1 L†R2 A3 / B3 A5 / B5 A15 10A 120 130 140 10B RGA
Mains Supply
Network Neutral Cabinet Supply Entry Cabinet Lamp Supply L Opening Magnet Relay Contact Partner L Opening Magnet Relay Contact Opening L Opening Signal K Closing Signal On/Off Signal Partner Security Circuit Neutral Cycle Stop circuit Plug Contact Circuit Max. 230Vac Lock Circuit Contactors' Neutral Output Regulator Monitoring Entry Only for VVVF or hydraulic systems
FRN
Break Monitoring Entry
ML1
ML1 or M1 Signal M signal
ML2 141
Descend slower stopper
Only used in VVVF non-geared engines
Magnetic switch entries. Signal connection varies as per drive type of elevator. It is used in hydraulic and VVVF systems, ML1, ML2 or Encoder numerator systems.
www.konelsan.com.tr
3. FAULT CODES CODE
1 2 3 4 5 7 8 9 10 11 13 14 15 16 17 18 19 20
ERROR STOP CAST PLUG CAST LOCK CAST KRC ERROR PTC ERROR NUMERATOR ERROR. JF ERROR LOCK NOT GIVEN PLUG NOT GIVEN NO KSR R - PHASE ERROR S - PHASE ERROR T - PHASE ERROR PHASES GONE LOW VOLTAGE (PRESS EXIT BUTTON FOR 60 SECONDS TO EXIT FAULT SCREEN) (PRESS EXIT BUTTON FOR 60 SECONDS TO EXIT FAULT SCREEN) (PRESS EXIT BUTTON FOR 60 SECONDS TO EXIT FAULT SCREEN) (THIS ERROR EPPEARS IF READING IS 817 OR 818 CUTTING)
www.konelsan.com.tr
14. PHYSICAL DIMENSIONS Front View
Card holding hole
m m 1 0 m 2
LCD indicator Adjustment Buttons
M3 screw 257mm