kriteria penggunaan waterproofing pada bangunanFull description
WaterproofingFull description
WaterproofingFull description
Full description
U.FL Connector Data sheet
MMCX Connector Data sheet
t24 connectorFull description
HFS
analisaDeskripsi lengkap
proposal penelitian polimerDeskripsi lengkap
This is not for saleFull description
Resumen de caso Harvard sobre American Connector Company.Descripción completa
sFull description
perhitungan shear connector pada struktur komposit baja dan beton.
Case study solution
perhitungan shear connector pada struktur komposit baja dan beton.Deskripsi lengkap
sDeskripsi lengkap
Descripción: Caso de harvard American Connector Company , preguntas resultas
Service manual for Nissan electrical connectors
Chevrolet Aveo 2006 ECM
analisaFull description
WORK INSTRUCTION 013
1 (5)
Network Implementation Site Engineer TI
January 25, 2008 Version 01
Work Instruction WI-013 Waterproofing of Connectors and Grounding Kits
WI-013
Confidential
1 of 5
WORK INSTRUCTION 013
2 (5)
Network Implementation Site Engineer TI
January 25, 2008 Version 01
1.
ALL external connections between jumpers/main feeder/Antenna must be waterproofed in accordance with the manufacturers installation instructions. Points to note are: • Make sure the connection is tight and dry.
•
On connections that are in the vertical plane, the first and last layer of any tape must be applied in an upward direction. This is to prevent water penetration.
Layer
1
2
3
4
5
Rubber / Vinyl
Rubber
Rubber
Rubber
Vinyl
Vinyl
Direction
• •
Single layer coatings (If used) must be applied in an upward direction. Each layer must overlap the ends of the previous layer by 25-50 mm. CABLE TIE 25
25
Layer 1, 2 and 3: STRETCH WRAPPED WRAPS OF SELF AMALGAMATING TAPE / RUBBER (STRETCH 30%, OVERLAPPING 50%) 1 WRAP OF INSULATION TAPE (OVERLAPPING
WI-013
Confidential
Layer 4 : STRETCH WRAPS OF INSULATION TAPE / Vinyl (OVERLAPPING 50%) Layer 5 (last): WRAPS of INSULATION TAPE / Vinyl WITH No STRETCH or pull.
2 of 5
WORK INSTRUCTION 013
3 (5)
Network Implementation Site Engineer TI
January 25, 2008 Version 01
•
The final turns of the last layer of tape must not be pulled or stretched, as this tends to unravel the tape after a short length of time.
•
The upper and lower ends of the waterproofing layer must be bunched with ties cable.
•
Many type of waterproofing material are used depend on the requirement. For rubber and vinyl where used because both of material more flexible to follow the connector surface.
WI-013
Confidential
3 of 5
WORK INSTRUCTION 013
4 (5)
Network Implementation Site Engineer TI
January 25, 2008 Version 01
2.
ALL external feeder groundings must be waterproofed in accordance with the manufacturers installation instructions. Note: If using Butyl type rubber waterproofing kits, the Butyl needs to be “Worked” like dough in order to get each layer to join with each other and become fully waterproof.
Grounding Kit and Connector
WI-013
Confidential
4 of 5
WORK INSTRUCTION 013
5 (5)
Network Implementation Site Engineer TI
January 25, 2008 Version 01
3.
Requirement points for waterproofing feeder system are showed on below picture: