SF46-486 ⌧ Regular
August 25, 2003
Safety
Credit/CallCode:
PROC ID:
Page 1 of 4
Job Code: 13310G Merchandise code:
DIVISION 46 SOURCE 106
REFRIG
FRESH FOOD SECTION NOT COLD BAFFLE FROSTED / ICED UP KENMORE BY WHIRLPOOL SIDE BY SIDE REFRIGERATORS WITH NON-ELECTRONIC INDEPENDENT INDEPENDENT TEMPERATURE CONTROL SYSTEMS MODELS:
See attached listing for Non-Electronic Independent Temperature Control (ITC) Models using Baffle P/N 2209751, Serial Numbers SM0999999 and before. NOTE: ITC model production was discontinued after SM0999999. CONDITION:
Interior moisture causes frost/ice buildup in the air chute and baffle area. Ice binds the gate in the closed position and breaks the linkage as the baffle tries to open. CORRECTION:
Replacement baffle assemblies with a stronger gate linkage are now available. See Fig. 1. Baffle Gate Original Improved
Figure 1
DEPARTMENT 702PSS – PRODUCT ENGINEERING MANAGER DEPARTMENT 702PSO – PARTS BUYER
SF46-486
August 25, 2003 Page 2 of 4 To minimize or eliminate interior moisture and frost buildup do the following: 1. Remove frost/ice buildup in the air chute or baffle area. 2. Replace the baffle. Make sure it is properly installed with no air leakage around its seal. Use Permagum or silicone (Silastic) to insure a tight seal. See Fig. 2. 3. Check door gasket for good seal. Correct if necessary. 4. Check ice chute door for complete closure. Repair as needed. 5. Seal the water reservoir tubing grommet opening with Permagum or silicone. See Fig. 3. 6. Check and seal mullion to deck rail gap with silicon. Also seal deck rail to inner liner, if needed. See Fig. 4. Permagum or silicone
Silicone gap
If needed Figure 2
Figure 3
Figure 4
7. Check top mullion to cabinet flange for offset gap. Repair gap with Spacer Kit #8201543 and seal according to kit instructions. See Fig. 5. 8. Check corner covers for air leaks and seal underneath side, if necessary. See Fig. 6.
Repair gap with Spacer Kit
Seal if separated
Figure 5
Seal underneath corner cover with silicone, if needed. Figure 6
DEPARTMENT 702PSS – PRODUCT ENGINEERING MANAGER DEPARTMENT 702PSO – PARTS BUYER
SF46-486
August 25, 2003 Page 3 of 4 9. Check and seal wiring harness grommet in the top of the ice and water dispenser housing". See Fig. 7
Figure 7
PARTS:
⌧
Order Part (see below) Truck stock NOT NOT recommended.
Verify by model number, and then order P/N 2209751 Baffle from Division 46, Source 106 following the normal ordering procedures. If needed, order Spacer Kit P/N 8201543.. NOTE: There are two very similar baffle assemblies. Figure 8 can can be used to correctly identify part number 2209751, the baffle used on non-electronic temperature control models.
Two harness connectors
White motor cover
Figure8
DEPARTMENT 702PSS – PRODUCT ENGINEERING MANAGER DEPARTMENT 702PSO – PARTS BUYER
SF46-XXX
Date Page 4 of KENMORE NON-ELECTRONIC MODELS with 2209751 BAFFLE (Serial Numbers SM0999999 and Before) 106.50202990
106.50585000
106.50792002
106.59297991
106.59599991
106.50202991
106.50585001
106.50793000
106.59297992
106.59599992
106.50202992
106.50587000
106.50793001
106.59297993
106.59599993
106.50202993
106.50589000
106.50793002
106.59297994
106.59702990
106.50203990
106.50589001
106.50794000
106.59299990
106.59702991
106.50203991
106.50592000
106.50794001
106.59299991
106.59702992
106.50203992
106.50592002
106.50794002
106.59299992
106.59702993
106.50203993
106.50592003
106.50799000
106.59299993
106.59704993
106.50204990
106.50593000
106.50799001
106.59299994
106.59707990
106.50204991
106.50593002
106.50799002
106.59502990
106.59707991
106.50204992
106.50593003
106.59202990
106.59502991
106.59707992
106.50204993
106.50594000
106.59202991
106.59502992
106.59707993
106.50209990
106.50594002
106.59202992
106.59502993
106.59709990
106.50209991
106.50594003
106.59202993
106.59504993
106.59709991
106.50209992
106.50599000
106.59204992
106.59507990
106.59709992
106.50209993
106.50599002
106.59204993
106.59507991
106.59709993
106.50502990
106.50599003
106.59207990
106.59507992
106.59792990
106.50502991
106.50702990
106.59207991
106.59507993
106.59792991
106.50502992
106.50703990
106.59207992
106.59509990
106.59792992
106.50503990
106.50704990
106.59207993
106.59509991
106.59792993
106.50503991
106.50709990
106.59209990
106.59509992
106.59794993
106.50503992
106.50782000
106.59209991
106.59509993
106.59797990
106.50504990
106.50782001
106.59209992
106.59592990
106.59797991
106.50504991
106.50784000
106.59209993
106.59592991
106.59797992
106.50504992
106.50784001
106.59292990
106.59592992
106.59797993
106.50509990
106.50785000
106.59292991
106.59592993
106.59799990
106.50509991
106.50785001
106.59292992
106.59594993
106.59799991
106.50509992
106.50787000
106.59292993
106.59597990
106.59799992
106.50582000
106.50789000
106.59292994
106.59597991
106.59799993
106.50582001
106.50789001
106.59294993
106.59597992
106.50584000
106.50792000
106.59294994
106.59597993
106.50584001
106.50792001
106.59297990
106.59599990
DEPARTMENT 702PSS – PRODUCT ENGINEERING MANAGER DEPARTMENT 702PSO – PARTS BUYER