Nuz − N 3741.54 − 2767 = = 0.36 Nuz − N 3741.54 − 1006.88 bal
a = βKH = 0.09248 × 0.36 × 0.3 = 9.98784 × 10 u
= Na = 2767 × 9.98784 × 10 M add, y u
Edifice Consultants (Pvt) Ltd
−3
− 3 = 27.63kNm
Basic Structural Element Designs to BS 8110-1:1997
Reference
Calculations
Cl.3.8.2.4
Minimum Moments
BS 8110-1:1997
exx = 0.05 × 500 = 25mm > 20mm M = 2767 × 0.020 = 55.34kNm < 153.8kNm xx,min e yy = 0.05 × 300 = 15mm < 20mm M = 2767 × 0.015 = 41.51kNm < 27.63kNm yy, min
Hence Design Moments
M = 153.8kNm xx M
Cl.3.8.4.5 BS 8110-1:1997
YY
= 41.51kNm
Biaxial Bending
b' = 300 − 30 − 10 −
h' = 500 − 30 − 10 −
25 2 25 2
= 247.5mm = 447.5mm
β = 0.3
M xx = 153.8 = 0.34 h′ 447.5 M yy b′
=
41.51 247.5
= 0.17
M M xx > YY h′ b′ Hence Column is Bending about XX axis. M′x = M + β x
Edifice Consultants (Pvt) Ltd
h′
447.5 × 41.51 = 176.32kNm M = 153.8 + 0.3 × b′ y 247.5
Output
Basic Structural Element Designs to BS 8110-1:1997
Reference
Column Design
Calculations Design of Main Reinforcement
Charts by IstructE d
447.5
=
h
≈ 0.90
500 N
=
bhf cu M
ρ=
3
300 × 500 × 30
=
2 bh f cu Hence
2767 × 10
176.32 × 10
= 0.61
3
2 300 × 500 × 30
ρf y
=
f cu
= 0.08
0.4
0.4 × 30 460
A
sc bh
=
A
sc bh
=
A
sc 2
=
0.4 × 30 460 0.4 × 30 460
×
2 300 × 500 = 3913mm
2 1956mm
Provided Reinforcement per Face is 4T25. A
sc,provided
=
2 1964mm
Hence provided Reinforcement is Satisfactory.
Table 3.25
Checks for Minimum Area of Reinforcement
BS 8110-1:1997
100A sc bh A sc =
= 0.4
0.4 × 300 × 500 100
= 600mm2
Hence provided reinforcement satisfied the minimum reinforcement requirement.
Edifice Consultants (Pvt) Ltd
Output
Basic Structural Element Designs to BS 8110-1:1997
Reference
Calculations Checks for Maximum Area of Reinforcement
Cl.3.12.6.1 BS 8110-
100Asc bh
=
6
1:1997 A sc =
6 × 300 × 500 100
= 9000mm2 > 3928mm2
Hence Maximum Area of Reinforcement is Ok. At Laps At a Lap 4T25 bars are lapped. 2 A sc = 12 × 491 = 5892mm A sc =
5892 300 × 500
× 100 = 3.93 < 10%
Cl.3.12.7.1
Design of Links
BS 8110-
Largest Compression bar
1:1997
Hence Diameter of the shear link should be larger than 25/4=6mm.
=25mm
Hence T10 Links were provided. Shear Link spacing should be less than 12 times smallest compression bar. (12x25=300mm) But link details required to mitigate seismic effects are stringent than this. Hence shear link details were provided to mitigate the seismic effects.
Design of Links to mitigate Seismic Effects
Detailing of the shear links were done as per “Reinforcement Detailing to mitigate seismic effects “ published by Society of Structural Engineers, Sri Lanka. Column confinement zone depth ( Adjacent to Beams) is greater of (a) 500mm (b)
lo
6
=
3400/6 ≈ 600mm
(c) Maximum dimension of column (500mm)
Edifice Consultants (Pvt) Ltd
Output
Basic Structural Element Designs to BS 8110-1:1997
Reference
Calculations
Hence Depth of the confinement zone is taken as 600mm. In confinement zones and at laps spacing of links/ cross ties shall be greater of (a) 100mm (b)
Minimum Column Dimension 3 300 3
but greater than 50mm
= 100mm > 50mm
Diameter of the links/ cross ties should be greater than 8mm. Hence T10 links at 100mm spacing provided throughout since column bears are lapped at two location between a given floor height.