Abstracted guidance for Design of Beams to BS 8110Full description
Structural Design Calculation
Design Calculation for a Staircase to BS 8110-1:1997Full description
Full description
design steps based on BS8110
Design Calculation for a Staircase to BS 8110-1:1997
BS 8110 P1 ExplanationFull description
Structural use of concrete — Part 1: Code of practice for design and constructionFull description
Design of an RC column to BS8110Full description
Full description
Design Example of Timber Column to BS 5268
Design of Concrete Column
Full description
Column DesignFull description
Tinh toan pakage.......
Basic Structural Elements Designs to BS 8110-Part 1:1997
3.0
COLUMN DESIGN
3.1
UNBRACED SHORT COLUMN DESIGN
X-X axis
Y-Y Axis
Y-Y Axis
X-X axis
Figure 3.1: General arrangement
Edifice Consultants Pvt.Ltd
Page 27
Basic Structural Elements Designs to BS 8110-Part 1:1997
Reference
Calculations
Out Put
Column is designed as un braced column. Cl.3.8.1.6
Calculation of Column effective height.
BS 8110-1:1997
Effective Length for X-X Plane Bending ( L ex )
L ox -Clear height between end restraints. L ox
= Floor
to Floor Height − Beam along Y direction
L ox
= 3600 − 600 =
3000mm
(Dimension of column for XX axis Bending h = 750 mm and Depth of the Beam along Y direction is 600mm.) Cl.3.8.1.6.2
Hence Top Condition is 1.
BS 8110-1:1997
Ground Beam Depth is 900mm. Hence Bottom Condition -1
Table 3.2
Hence β = 1.2
BS 8110-1:1997
L ex L ex h
= βL ox = 1.2 × 3000 = 3600mm =
3600 750
=
4.8 < 10
Hence Column is short in X-X direction.
Cl.3.8.1.6
Effective Length for Y-Y Plane Bending ( L ey )
BS 8110-1:1997
See Figure 1. L oy -Clear height between end restraints. L oy =Floor to Floor Height-Beams along Y direction
L oy
=
3600 − 600 = 3000mm
Other Design Information
f cu
2
= 30N/mm
Cover to Reinforcement is 30mm. T25 Main bars and T10 Links are to be used.
Edifice Consultants Pvt.Ltd
Page 28
Basic Structural Elements Designs to BS 8110-Part 1:1997
Reference
Calculations
Out Put
(Depth of the Beam along X direction is 600mm.) Cl.3.8.1.6.2
Hence Top Condition is 1.
BS 8110-1:1997
Ground Beam Depth is 900mm. Hence Bottom Condition -1
Table 3.2
Hence β = 1.2
BS 8110-1:1997
L ey
= βL oy = 1.2 × 3000 = 3600mm
L ey
=
b
3600 400
= 9 < 10
Hence Column is short in Y-Y direction.
Short Column
Hence column is a short column.
Cl.3.8.1.7
Checks for Slenderness limit of un braced column
BS 8110-1:1997
L oy
= 3000mm
60b = 60 × 400 = 24000 L oy
< 60b
Hence Slenderness Limit is Ok.
Design Loads from SAP 2000 Model
Column is designed for ULS 1 Load Combination.(Critical) N = 5464 kN
Mxx
Myy
Edifice Consultants Pvt.Ltd
=
524 kNm
=
23kNm
Page 29
Basic Structural Elements Designs to BS 8110-Part 1:1997
Reference
Calculations
Cl. 3.8.2.4
Checks for Minimum Eccentricity
BS 8110-1:1997
Minimum eccentricity in X-X Plane Bending emin , x
=
0.05h or 20 mm which ever is greater
emin , x
=
0.05 × 750 = 37.5mm
Out Put
Hence minimum eccentricity is 20mm. Hence M min,x
= Ne
min,x
= 0.020 × 5464 = 109.28kNm < 524kNm
Hence Design moment about X-X axis taken as 524kNm. Minimum eccentricity in Y-Y Plane Bending
emin,y
=
e min , x
0.05b or 20mm which ever is greater
= 0.05 × 400 = 20mm
Hence minimum eccentricity is 20mm. Hence Mmin , x
= Ne
min , x
= 0.020 × 5464 = 109.28kNm > 20.3kNm
Hence Design moment about Y-Y axis taken as 109.28kNm.
Reinforcement Design for Column (See Figure 3.2)
h′ = 750 − 30 − 10 −
b′ = 400 − 30 − 10 − Mx h′
=
My b′ Mx h′
=
>
524 697.5
=
109.28 347.5
25 2 25 2
=
697.5mm
=
347.5mm
0.75
=
0.31
My b′
Hence Column is designed for an increased moment about X-X axis.
Edifice Consultants Pvt.Ltd
Page 30
Basic Structural Elements Designs to BS 8110-Part 1:1997
Figure 3.2: Column axis convention
Figure 3.3: Reinforcement Detailing of the Column Section
Edifice Consultants Pvt.Ltd
Page 31
Basic Structural Elements Designs to BS 8110-Part 1:1997
Reference
Calculations
M′x
= Mx +
7
β =1−
=
7 6
M 2 bh f cu
h
My
N
×
5464 × 10
3
400 × 750 × 30 697.5 347.5
5464 × 10
=
bhf cu
=
b′
524 + 0.3 ×
N
d
′
6 bhf cu
β =1−
M′x
h
Out Put
702.5 750
× 109.28 =
=
6 590 × 10 2 400 × 750 × 30 =
590kNm
3
400 × 750 × 30
=
= 0.29 < 0.3
0.61
= 0.09
0.93
From Appendix D of “Manual for the Design of Reinforced Concrete Building Structures”
ρf y
= 0.42
f cu ρ=
As
As bh
= 0.42 ×
30 460
2
× 400 × 750 = 8217mm
The area of reinforcement should be detailed in as per Figure 8.3. Table 3.25
Checks for Minimum Area of Reinforcement
100A sc bh A sc
=
= 0.4
0.4 × 400 × 750 100
2
= 1200mm
Provided reinforcement satisfied the minimum reinforcement requirement.
Edifice Consultants Pvt.Ltd
Page 32
Basic Structural Elements Designs to BS 8110-Part 1:1997
Reference
Calculations
Cl. 3.8.2.4
Checks for maximum area of reinforcement
BS 8110-1:1997
100A sc bh A sc
=
Out Put
=6
6 × 400 × 750
100
= 18000mm
2
Hence provided area of reinforcement is within the maximum allowable.
At Laps At a Lap 8T25 bars are lapped. Hence Total 24 Bars ar e at the cross section (16+8) 2
A sc
= 24 × 491 = 11784mm
A sc
=
11784 × 100 750 × 400
Cl. 3.8.4.6
Checks for Shear
BS 8110-1:1997
Mx N
=
590 5464
= 3.93% < 10%
= 0.11
0.6h = 0.6 × 0.750 = 0.45
Hence a shear check is not required.
Cl.3.12.7.5
Design of Links
BS 8110-1:1997
Largest Compression bar
=25mm
Hence Diameter of the shear link should be larger than 25/4=6mm. Hence T10 Links were provided. Shear Link spacing should be less than 12 times smallest compression bar. (12x20=240mm) But link details required to mitigate seismic effects are stringent than this. Hence shear link details were provided to mitigate the seismic effects.
Edifice Consultants Pvt.Ltd
Page 33
Basic Structural Elements Designs to BS 8110-Part 1:1997
Reference
Calculations
Out Put
Design of Links to mitigate Seismic Effects
Detailing of the shear links were done as per “Reinforcement Detailing to mitigate seismic effects “ published by Society of Structural Engineers, Sri Lanka. Column confinement zone depth ( Adjacent to Beams) is greater of (a) 500mm (b)
lo
6
= 500mm
(c) Maximum dimension of column (750mm) Hence Depth of the confinement zone is taken as 750mm. In confinement zones and at laps spacing of links/ cross ties shall be greater of (a) 100mm (b)
Minimum Column Dimension 3
400 3
but greater than 50mm
= 133.33mm > 50mm
Diameter of the links/ cross ties should be greater than 8mm. Hence T10 links at 100mm spacing provided throughout since column bars are lapped at two location between a given floor height.