DESCRIPTION 5.. Steel Structure Supply and Construct Steel Super Structure Consisting of
A.
Wall Wall and and Ro Roof of Mate Materi rial al Wa c a ng s requ re rom groun up to roof leaving opening to doors and windows Wall panel is aluminium sandwitch panel thickness of 5 cm Roof panel is aluminium sandwitch panel thickness of 5 cm Insulation at whole roof area ( Fiber glass 50 mm thick 10 kg/M3)
B
Structural St Steel Purlins of UPN 200 spaced @1.50 mt connected to the truss with angle cleat wind bracing for roof as shown in the drawing purlin rods as shown in the drawing Rafter beams of IPE 360 Columns of IPE 360 Connections beween beween rafter and rafter as well as rafter and columns with Bolts of Grade 8.8 Wall bracing as shown in the drawing Anchor bolts with plates to connect steel column with the concrete column
C
Other items Eave gutter and down pipes spout on side walls with projection, All neceesary flashings and trims, foam closer , end lap mastic, connection bolts , sheeting fastener and bed mastic etc Complete work all accoring to drawing.
K2N Architecture and Engineering Consultancy Plc
Block :
UNIT
QTY
Energy Cable
RATE
AMOUNT
Project : Cable factory , PSYGEN - BM
ITEM
DESCRIPTION
K2N Architecture and Engineering Consultancy Plc
Block :
UNIT
QTY
Energy Cable
RATE
AMOUNT
Project : Cable factory , PSYGEN - BM
ITEM
DESCRIPTION
K2N Architecture and Engineering Consultancy Plc
Block :
UNIT
QTY
Energy Cable
RATE
AMOUNT
Project : Cable factory , PSYGEN - BM
ITEM
DESCRIPTION
Block :
UNIT
5.. Steel Structure Supply and Construct Steel Super Structure Consisting of A.
Wall and Roof Material Wa c a ng s requ re rom groun up to roof leaving opening to doors and windows Wall panel is aluminium sandwitch panel thickness of 5 cm Roof panel is aluminium sandwitch panel thickness of 5 cm Insulation at whole roof area ( Fiber glass 50 mm thick 10 kg/M3)
B
Structural Steel Purlins of UPN 200 spaced @1.50 mt connected to the truss with angle cleat wind bracing for roof as shown in the drawing purlin rods as shown in the drawing Rafter beams of IPE 360 Columns of IPE 360 Connections beween rafter and rafter as well as rafter and columns with Bolts of Grade 8.8 Wall bracing as shown in the drawing Anchor bolts with plates to connect steel column with the concrete column
C
Other items Eave gutter and down pipes spout on side walls with projection, All neceesary flashings and trims, foam closer , end lap mastic, connection bolts , sheeting fastener and bed mastic etc Complete work all accoring to drawing. 1