Flow sensors and transmitters, flow meters
The flow rate meter type SU is an inline flow rate meter. The propagation time of the sound depends to a large extent on the medium (gaseous, liquid). Therefore information about the type of medium must be given to the measuring system so that the respective correction factors can be included. In addition to simple flow rate monitoring the SU also monitors the temperature of the medium. It is displayed on site and provided for signal processing. This makes the system particularly suitable for the monitoring of cooling circuits, because temperature and flow rate can be monitored at the same time. The processed information for integration into the process and further processing is of course important for the user. The SU provides a variety of possibilities for representing and processing the data. In addition to the display of all settings and process data on site there are also various possibilities of signal processing. If continuous documentation of processes is required the measured values are available via analogue outputs (0...10 V / 4...20 mA). Binary evaluation of measured values is part of the standard. Pulse outputs for counting and totaliser functions are available internally as well as externally. There is also the possibility to allocate an output to the function of a preset counter. In this case a switched signal is provided after a preset flow rate. The operating principle is simil ar to that of an electronic water meter. A compact design which is ready for connection and can be adapted to various process connections enables the SU ultrasonic flow rate meter to be used in a wide range of applications. All functions described here can be set directly on site via alphanumeric menu navigation, but they can also be set before installation.
1
2
3
1. Piezoceramic sound transducer 2. Measuring length 3. Piezoceramic sound transducer Differential tran sit time principle: Sound pulses are alternately emitted and detected in and against the direction of flow
using piezoceramic sound transducers. The flow rate is exactly calculated from the difference of the transit time (in the nanosecond range from 0.5 to 500 ns). Reliably, wear-and maintenance-free.
n o i l t a a r m e r n f o e n G i s e l c i t r a f o t s i L s r o s n e s l e v e L s r o s n e s w o l F
e s r r u s o s s e r n P e s e r u t a s r e r p o m s e n T e s
c i t s s o m n e g t a s i y D s s e i l p n p o , u i t s s r a m e u t e l a s w v y o E s p
Four-digit alphanumeric display for information on site: Current flow rate, accumulated total quantity and medium temperature. l/min or m3/ h can be selected as the unit of measurement. Two LEDs indicate the switch points.
n y o g i o t c l e o n n h n c o e C t
s e i r o s s e c c A r n e o m l i t o a s e c a t i u c n m r c i h o d v c f e n n r e T i a s
Visit our website: www.ifm-electronic.com
45
Flow sensors and transmitters, flow meters
Flow sensors
Housing / Process connection
Application / Medium Flow range temperature
Selection chart
Supply voltage DC
[cm/s]
AC
[°C]
Application
Sensor material Stainless Titanium steel Page Page
PTFE Page
Thermal flow sensors and transmitters with integrated control monitor type SI5... sealing cone fitting adapter
liquids: 3...300 gases: 200...3000
-25...80
•
•
52 / 54
–
–
ifm adapter thread
liquids: 3...300 gases: 200...3000
-25...95 -25...120*
•
–
66
–
–
mounting clamp
air: 100...1000
-10...50
•
•
–
–
58
56
–
–
type SI6...
type SLG
Thermal flow sensor with integrated control monitor for flow and temperature detection type SI5... sealing cone fitting adapter
* max. 1 hour at 60 °C operating temperature
For industrial applications
46
For hygienic areas and viscous media
For hazardous areas
liquids: 3...300 gases: 200...3000
-25...80
•
–
Flow sensors and transmitters, flow meters
Flow sensors
Housing / Process connection
Application / Flow range
Selection chart
Medium temperature [°C] -20...60 -20...80 0...120
[cm/s]
Application
Sensor material Stainless Titanium Ceramic steel Page Page Page
Thermal flow sensors with external control monitor type SF (ceramic) G 1/4
liquids: 0...60
–
•
–
–
–
63
G 1/2
liquids: 0...60
–
•
–
–
–
63
G 1/2
liquids: 0...60
–
•
–
–
–
63
G 1/4
liquids: 0...60
–
•
–
–
–
63
type SF (ceramic)
type SF (ceramic)
type SF (ceramic)
For industrial applications
48
For hygienic areas and viscous media
For hazardous areas
General information
Notes and explanations
5-
7
9 - 15
s e l c i t r a f o t s i L
17 - 3 5
s r o s n e s l e v e L
List of articles
Order numbers in alphanumeric order
Level sensors
Continuous and point level measurement
Flow sensors
Flow sensors and transmitters, flow meters
37 - 7 7
Pressure sensors
Pressure sensors and transmitters
79 -127
Temperature sensors
Temperature sensors and transmitters
129 -153
Diagnostic systems
Systems for vibration diagnosis
155 -171
Evaluation systems, power supplies
Connection technology
Accessories
Technical information and customer service
n o i l t a a r m e r n f o e n G i
s r o s n e s w o l F
e s r r u s o s s e r n P e s e r u t a s r e r p o m s e n T e s
c i t s s o m n e g t a s i y D s s e i l p n p o , u i t s s r a m e u t e l a s w v y o E s p
Amplifiers, transformer and switched-mode power supplies
173 -189
Complete ifm product range
191 -215
Accessories fluid sensors and diagnostic systems
217 - 228
Wiring diagrams Scale drawings Technical glossary ifm information and ordering service
232 - 234 236 - 271 272 - 281 282 - 291
n y o g i o t c l e o n n h n c o e C t
s e i r o s s e c c A r n e o m l i t o a s e c a t i u c n m r c i h o d v c f e n n r e T i a s
3
Flow sensors and transmitters, flow meters
Housing / Dimensions
Monitoring Flow
[mm]
Flow / Temperature
Flow / Wire
Application
DC
AC
Page
Page
Control monitors
s e l c i t r a f o t s i L
type VS3000 25 x 103.5 x 100
•
•
•
64
n o i l t a a r m e r n f o e n G i
64
s r o s n e s l e v e L
type VS0200 Ex-i 55 x 75 x 110
–
–
•
70
s r o s n e s
70
w o l F
e s r r u s o s s e r n P e s e r u t a s r e r p o m s e n T e s
c i t s s o m n e g t a s i y D s s e i l p n p o , u i t s s r a m e u t e l a s w v y o E s p
n y o g i o t c l e o n n h n c o e C t
s e i r o s s e c c A r n e o m l i t o a s e c a t i u c n m r c i h o d v c f e n n r e T i a s
For industrial applications
For hygienic areas and viscous media
For hazardous areas
49
Flow sensors and transmitters, flow meters
Flow sensors
Housing / Process connection
Measuring Measuring principle range Nm3 / h Nl / min