Junos Enterprise Switching
Chapter 7: High Availability
© 2011 Juniper Networks, Inc. All rights reserved. | www.juniper.net | Worldwide Education Services
Chapter Objectives After successfully completing this chapter, you will be
able to: • List and describe features that promote high availability • Configure and monitor high availability features • Describe key concepts and components of a Virtual Chassis • Explain the operational details of a Virtual Chassis • Implement a Virtual Chassis and verify its operations
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-2
Agenda: High Availability Overview of High Availability Networks Link Aggregation Groups Redundant Trunk Groups Virtual Chassis
• Overview of Virtual Chassis • Configuring and Monitoring a Virtual Chassis
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-3
What Is High Availability? The ability to ensure a high degree of operational
continuity to a resource for a user community • Typically measured over a specific period of time
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-4
High Availability Networks High availability networks include provisions that allow
for the maximum amount of uptime and accessibility 1. Is the base functionality of the network’s hardware, software, protocols, and overall operations protected? 2. When a failure occurs, how will the overall system or network react and what level of recovery can be expected?
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-6
High Availability Features EX Series switches support a number of features to
help increase uptime and availability including: • Link aggregation groups (LAGs) • Redundant Trunk Groups (RTG) • Virtual Chassis
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-7
Agenda: High Availability Overview of High Availability Networks Link Aggregation Groups Redundant Trunk Groups Virtual Chassis
• Overview of Virtual Chassis • Configuring and Monitoring a Virtual Chassis
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-8
What Is It? Link aggregation combines multiple Ethernet
interfaces in to a single link layer interface, also known as a link aggregation group (LAG) or bundle • Defined in the 802.3ad standard Participating interfaces are known as member links
Commonly used on trunk port connections Switch-1
ge-0/0/12
Switch-2
ge-0/0/13
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-9
Benefits of 802.3ad Link Aggregation Benefits of 802.3ad link aggregation include:
• Increases bandwidth • Provides link efficiency • Creates physical layer redundancy
Switch-1
ge-0/0/12
Switch-2
ge-0/0/13
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-10
Link Requirements and Considerations Interface requirements and considerations include:
• Duplex and speed must match • Up to eight member links per LAG • Member links do not need to be contiguous ports nor must
they be on the same switch when part of a Virtual Chassis Switch-2
Switch-1 ge-0/0/1 … … … ge-0/0/5 ge-0/0/10 … … ge-0/0/13
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-11
Traffic Processing and Forwarding Traffic processing and forwarding considerations:
• RE generated traffic is always sent on the lowest member link • IP traffic hashing uses Layer 2, Layer 3, and Layer 4 details • Non-IP traffic hashing uses source and destination MAC addresses RE traffic
Switch-2
Switch-1 ge-0/0/1
IP traffic Non-IP traffic ge-0/0/13
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-12
Link Aggregation Control Protocol LACP performs link monitoring and controls the
member links that form a single logical channel You can set the LACP mode as active or passive:
• Active mode initiates transmission of LACP packets • Passive mode responds to LACP packets Switch-1 ae1
Switch-2 ae1
ae0
ae0
Note: At least one device must be configured for active mode for the link to become operational. © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-13
Implementing LAGs (1 of 2) Create an aggregated Ethernet interface: {master:0}[edit chassis] user@Switch-1# run show interfaces terse | match ae0 {master:0}[edit chassis] user@Switch-1# set aggregated-devices ethernet device-count 1 {master:0}[edit chassis] user@Switch-1# commit configuration check succeedscommit complete {master:0}[edit chassis] user@Switch-1# run show interfaces terse | match ae0 ae0 up down
Link state remains down until operational member links are added to LAG
Switch-2
Switch-1 ge-0/0/12 ae0
ae0 ge-0/0/13
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-14
Implementing LAGs (2 of 2) Configure the aggregated Ethernet interface and
associate desired member links with the LAG: {master:0}[edit interfaces] user@Switch-1# set ae0 unit 0 f amily ethernet-swit ching {master:0}[edit interfaces] user@Switch-1# set ae0 aggregated-ether-options lacp active {master:0}[edit interfaces] user@Switch-1# set ge-0/0/12 ether-options 802.3ad ae0 {master:0}[edit interfaces] user@Switch-1# set ge-0/0/13 ether-options 802.3ad ae0 {master:0}[edit interfaces] user@Switch-1# commit configuration check succeedscommit complete {master:0}[edit interfaces] user@Switch-1# run show interfaces ge-0/0/12.0 up up ge-0/0/13.0 up up ae0 up up ae0.0 up up
© 2011 Juniper Networks, Inc. All r ights reserved.
terse | match ae0 aenet --> ae0.0 aenet --> ae0.0
Switch-2
Switch-1 ge-0/0/12 ae0
ae0 eth-switch
Worldwide Education Services
ge-0/0/13
www.junip er.net | 7-15
Monitoring LAGs Use the
show interfaces output to determine
state information for aggregated interfaces: {master:0} user@Switch-1> show interfaces terse | match ae0 ge-0/0/12.0 up up aenet --> ae0.0 ge-0/0/13.0 up up aenet --> ae0.0 ae0 up up ae0.0
up
up
eth-switch
{master:0} user@Switch-1> show interfaces extensive ae0.0 | LACP Statistics: LACP Rx LACP Tx ge-0/0/12.0 26 516 ge-0/0/13.0 25 519 Marker Statistics: Marker Rx Resp Tx ge-0/0/12.0 0 0 ge-0/0/13.0 0 0 Protocol eth-switch, Generation: 195, Route Flags: None
find "LACP Statistics:" Unknown Rx Illegal Rx 0 0 0 0 Unknown Rx Illegal Rx 0 0 0 0 table: 0
• Note that other commands exist that show similar details
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-16
Test Your Knowledge Given the sample outputs, can you guess what might
be causing ae0.0 to remain in the down state? {master:0} lab@Switch-1> show interfaces terse | match ae0 ge-0/0/12.0 up up aenet --> ae0.0 ge-0/0/13.0 up up aenet --> ae0.0 ae0 up down ae0.0
up
down eth-switch
{master:0} lab@Switch-1> show interfaces extensive ae0.0 | find "LACP Statistics:" LACP Statistics: LACP Rx LACP Tx Unknown Rx Illegal Rx ge-0/0/12.0 0 224 0 0 ge-0/0/13.0 0 223 0 0 Marker Statistics: Marker Rx Resp Tx Unknown Rx Illegal Rx ge-0/0/12.0 0 0 0 0 ge-0/0/13.0 0 0 0 0 Protocol eth-switch, Generation: 195, Route table: 0 Flags: None
• The remote device does not have LACP enabled
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-17
Agenda: High Availability Overview of High Availability Networks Link Aggregation Groups Redundant Trunk Groups Virtual Chassis
• Overview of Virtual Chassis • Configuring and Monitoring a Virtual Chassis
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-18
What Is It? A redundant trunk group provides a quick and simple
failover mechanism for redundant Layer 2 links • Can be used as a replacement for STP on access switches that are connected to two aggregation switches Switch-1
ge-0/0/1
Switch-2
RSTP ge-0/0/2
RTG Switch-3
© 2011 Juniper Networks, Inc. All r ights reserved.
Switch-4
Worldwide Education Services
Switch-5
www.junip er.net | 7-19
How Does It Work? Only active link is used to forward traffic, other links
serve as backup links and do not forward traffic • When active link fails, a backup link becomes active
Switch-1
ge-0/0/1
Switch-2
ge-0/0/2
Switch-3
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-20
Configuration Considerations RTG is typically only configured on access switches
• RTG and STP are mutually exclusive on a given port • STP BPDUs received on RTG links are discarded • STP is configured on aggregation switches Switch-1 RSTP
ge-0/0/1
Switch-2
ge-0/0/2
ge-0/0/8
ge-0/0/10
RTG Switch-3
Switch-4
Switch-5
Note: A maximum of 16 redundant trunk groups per switch. © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-21
Case Study: Topology and Objectives Objectives:
• Implement RTG on Switch-3 to ensure that only a single path is available toward the aggregation switches • Ensure that Switch-3 forwards user traffic out ae0.0 whenever it is operational Switch-1
Switch-2
Switch-3
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-22
Case Study: Configuring RTG You configure RTG under the [edit ethernet-
switching-options] hierarchy: {master:0}[edit ethernet-switching-options] user@Switch-3# set redundant-trunk-group group rtg-1 interface ae0.0 primary {master:0}[edit ethernet-switching-options] user@Switch-3# set redundant-trunk-group group rtg-1 interface ge-0/0/10.0 {master:0}[edit ethernet-switching-options] user@Switch-3# show redundant-trunk-group { group rtg-1 { interface ge-0/0/10.0; interface ae0.0 { primary; } } }
Interface marked as primary is always active when operational
Switch-1
Switch-2
Switch-3
Note: If primary knob is omitted, highest-numbered interface initially becomes active link but does not preempt lower-numbered interfaces functioning as the active link in failure and recovery scenarios © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-23
Case Study: Monitoring RTG Use
show redundant-trunk-group to monitor
RTG operations: {master:0} user@Switch-3> show redundant-tr unk-group Group Interface State Time of last flap name rtg-1
ae0.0 Up/Pri/Act ge-0/0/10.0 Up
Flap count
Never Never
0 0
(Pri) = Primary interface with preemption enabled (Act) = Active interface currently forwarding traffic Switch-1
Switch-2
ae0.0 is selected as the primary interface for the rtg-1 RTG group
Switch-3 © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-24
Lab 6: Implementing LAGs and RTG Configure and monitor LAGs and RTG.
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-25
Agenda: High Availability Overview of High Availability Networks Link Aggregation Groups Redundant Trunk Groups Virtual Chassis Overview
of Virtual Chassis
• Configuring and Monitoring a Virtual Chassis
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-26
What Is It? Two or more interconnected EX Series switches
operating as a single Virtual Chassis system Valid chassis combinations
• Two or more (up to 10) EX4200s • Two EX4500s • Two EX4500s with up to eight EX4200s • Two EX8200s including an external routing engine
Up to 10 switches can be interconnected © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-27
Benefits of Virtual Chassis Virtual Chassis benefits include:
• High availability: Redundant REs • Enables the use of NSR
• Simplified network design: Single network entity to manage,
configure, monitor;switches potential elimination of STP; flexible placementand of member
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-29
Virtual Chassis Components Virtual Chassis components include:
• EX Series switches • Participating switches serve as REs or line cards (LCs)
• Virtual Chassis ports (can be dedicated VCPs or uplink ports
converted to extended VCPs through configuration)
• VCPs interconnect PFEs from one switch to another to form a single backplane
Location 1
© 2011 Juniper Networks, Inc. All r ights reserved.
Location 2
Worldwide Education Services
www.junip er.net | 7-31
Virtual Chassis Cabling Options (1 of 3) Dedicated Virtual Chassis daisy-chained ring method
• Longest cable spans the entire Virtual Chassis; maximum length between end systems is 5 meters
Note: The EX4200 Series switches come with a .5 meter cable. You can acquire longer cables in lengths of 1, 3, and 5 meters. © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-32
Virtual Chassis Cabling Options (2 of 3) Dedicated Virtual Chassis braided ring method
• Maximum length between end devices in a Virtual Chassis consisting of 10 EX Series switch is 22.5 meters
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-33
Virtual Chassis Cabling Options (3 of 3) Extended Virtual Chassis ring method
• Maximum circumference of ring using is 100 km; uses 1 GbE or 10 GbE uplinks to extend the distance of the Virtual Chassis
This option is required when the circumference of a Virtual Chassis exceeds 22.5 meters. This option is often used to interconnect wiring closets or data center racks or rows. © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-34
Recommended RE Placement (1 of 2) RE placement recommendations:
• Ensure spatial redundancy and avoid split Virtual Chassis issues and other failure conditions by evenly spacing the master and backup REs (by hop) and by separating REs from uplinks Uplink Uplink
Uplink
Uplink
Dedicated Virtual Chassis daisy-chained ring
© 2011 Juniper Networks, Inc. All r ights reserved.
Dedicated Virtual Chassis braided ring
Worldwide Education Services
www.junip er.net | 7-35
Recommended RE Placement (2 of 2) RE placement recommendations (contd.):
• When implementing an extended Virtual Chassis, you should place the master and backup REs in different locations
Location 2
Location 1
Extended Virtual Chassis ring
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-36
Master and Backup Election Mastership determination: 1. Member with the highest user-configured priority • Priority range is 1–255, factory-default value is 128
2. Member previously functioning as master prior to reboot 3. Member with the longest standing uptime • Difference must be greater than 1 minute
4. Member with the lowest MAC address
• Used as tie breaker if all is equal through the first three determination steps
5. Second member in election decision tree becomes backup switch; all other members are line cards Note: If a master or backup fails, one of the line card switches is elected the new backup switch using the same criteria.
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-37
Member ID and Interface Names All member switches are assigned a member ID (0 –9)
• Member ID is assigned manually through configuration or dynamically from the master switch (usually member ID 0) • Member ID is preserved through reboots • Member ID serves as slot number for interface naming
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-38
Replacing a Member Switch When a member switch is removed, its member ID is
not automatically released and made available nor will the replacement switch automatically inherit the configuration associated with the previous switch • Recommended replacement steps: 1.
Recycle the member ID of the switch being replaced so it becomes the next-lowest available unused member ID
2.
Add replacement switch which should automatically be assigned the recycled member ID and inherit the required configuration
{master:0} user@Switch-1> request virtual-chassis recycle member-id
Note: You recycle member IDs on the master switch. © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-40
Think About It! Given the member ID assignments, what are the
interface names for the highlighted interfaces? • Hint: All member switches are 48 port models and all interfaces are Gigabit Ethernet interfaces Location #2
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-41
Management Connectivity (1 of 2) Single management interface and IP address
• Individual management Ethernet ports (me0) on member switches are tied to a special management VLAN associated with a Layer 3 virtual management Ethernet (VME) interface • The Virtual Chassis system is managed as a single network element; therefore, it has only one management IP address {master:0}[edit] user@Switch-1# show interfaces vme unit 0 { family inet { address 10.210.14.148/27; } } {master:0}[edit] user@Switch-1# run show interfaces terse vme Interface Admin Link Proto Local vme up up vme.0 up up inet 10.210.14.148/27
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
Remote
www.junip er.net | 7-42
Management Connectivity (2 of 2) Single virtual console
• Connection to a console on any member switch in a Virtual Chassis system is redirected to the master switch by the virtual console software running on all member switches
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-43
Software Upgrades You can perform software upgrades for a single
Virtual Chassis member or for all members from the master switch {master:0} user@Switch-1> request system software add member ? Possible completions: Install package on VC Member (0..9)
Master switch performs a software compatibility
check for each member added to the Virtual Chassis • If a version mismatch exists, a syslog message is generated and the newly added switch is placed in an inactive state • Upgrade incompatible switches from the master switch manually or enable the automatic software upgrade option
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-44
Topology Discovery (1 of 3) Virtual Chassis members use VCCP to create a loop-
free topology • LSA-based discovery messages are exchanged between all PFEs and build the member switch and PFE topology maps • Each switch runs the shortest-path first (SPF) algorithm for each PFE which creates PFE map tables between all PFEs • Each PFE builds source ID egress filter tables used to prevent broadcast and multicast packets from looping Switch-1
Switch-2
Switch-3
VCCP LSA-based messages Virtual Chassis cables and backplane
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-45
Topology Discovery (2 of 3) Topology discovery example:
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-46
Topology Discovery (3 of 3) Topology discovery example (contd.):
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-47
Inter-Chassis Packet Flow Packets always take the shortest path through a
Virtual Chassis • Shortest path is determined by hop count and bandwidth • Inter-chassis packet flow examples: 1.
Packets going from ge-0/0/10 to ge-3/0/14 pass through member 4 because it is a shorter path
2.
Packets going from ge-0/0/28 to ge-2/0/47 pass through member 1 because it is a shorter path
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-48
Agenda: High Availability Overview of High Availability Networks Link Aggregation Groups Redundant Trunk Groups Virtual Chassis
• Overview of Virtual Chassis Configuring
and Monitoring a Virtual Chassis
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-49
Virtual Chassis Configuration You enable Virtual Chassis configuration options under
the [edit virtual-chassis] hierarchy: {master:0}[edit virtual-chassis] user@Switch-1# set ? Possible completions: + apply-groups Groups from which to inherit configuration data + apply-groups-except Don't inherit configuration data from these groups > Auto > auto-sw-update fast-failover Fast software failover update mechanism id Virtual Chassis identifier, of type ISO system-id > mac-persistence-timer How long to retain MAC address when member leaves Virtual Chassis > member Member of Virtual Chassis configuration no-split-detection Disable split detection. Only recommended in a 2 member setup preprovisioned Only accept preprovisioned members > traceoptions Global tracing options for Virtual Chassis
• To minimize traffic interruption during an RE failover scenario, enable graceful Routing Engine switchover: {master:0}[edit chassis] user@Switch-1# set redundanc y graceful-swit chover? Possible completions: > graceful-switchover Enable graceful switchover on supported hardware © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-50
Dynamic Configuration Process (1 of 2) Dynamic configuration steps:
1. Install desired master switch: •
Power up desired master switch, switch becomes master and obtains member ID 0, assign mastership priority 255
Master (Active RE) ON
Backup (Backup RE) ON
Linecard
2. Add desired backup switch: •
Connect to master switch using Virtual Chassis cable, power up desired backup switch, switch is elected as backup and dynamically assigned member ID 1, assign mastership priority 255
Linecard
Linecard
{master:0}[edit virtual-chassis] user@Switch-1# set member mastership-pr iority © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-52
Dynamic Configuration Process (2 of 2) Dynamic configuration steps (contd.): Master (Active RE)
3. Add line card switch: •
ON
Connect to switch above with VCB cable, power up third switch —switch becomes line card and is dynamically
Backup (Backup RE)
assigned member ID 2, assign desired mastership priority
Linecard
ON
ON
4. Repeat Step 3 to add subsequent line card switches: •
Last line card switch completes loop by connecting with master
Linecard ON
Linecard ON
{master:0}[edit virtual-chassis] user@Switch-1# set member mastership-pr iority © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-53
Preprovisioned Configuration Example {master:0}[edit virtual-chassis] user@Switch-1# show preprovisioned; member 0 { role routing-engine; serial-number BM0208105168; } member 1 { role line-card; serial-number BM0208124111;
Note when preprovisioned option is used, you do not specify a mastership priority but rather only assign the role to a given device.
} member 2 { role routing-engine; serial-number BM0208124231; } member 3 { role line-card; serial-number BM0208124333; }
Note: You should power on the switch designated as RE0 first, create and activate the desired preprovisioned configuration, and then add the remaining switches. © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-54
Monitoring Virtual Chassis Operations Use the
show virtual-chassis commands to
monitor Virtual Chassis operations: {master:0} user@Switch-1> show virtual-chassis ? Possible completions: <[Enter]> Execute this command active-topology Virtual Chassis active topology device-topology PFE device topology fast-failover Fast failover status login protocol Show Virtual Chassis protocol information status Virtual Chassis information vc-path Show virtual-chassis packet path vc-port Virtual Chassis port information | Pipe through a command
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-55
Verifying Virtual Chassis Port State Use
show virtual-chassis vc-port to view
VCP state and details: {master:0} user@Switch-1> show virtual-chassis vc-port fpc0: -------------------------------------------------------------------------Interface Type Trunk Status Speed Neighbor or ID (mbps) ID Interface PIC / Port vcp-0 Dedicated 2 Up 32000 1 vcp-0 vcp-1 Dedicated 1 Up 32000 1 vcp-1 fpc1: -------------------------------------------------------------------------Interface Type Trunk Status Speed Neighbor or ID (mbps) ID Interface PIC / Port vcp-0 Dedicated 2 Up 32000 0 vcp-0 vcp-1 Dedicated 1 Up 32000 0 vcp-1
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-56
Enabling and Disabling Virtual Chassis Ports Built-in VCPs (vcp-0/vcp-1) are enabled by default
• You can disable or re-enable VCPs in operational mode: {master:0} VC user@Switch-1> request virtual-chassis vc-port set interface vcp-0 disable {master:0} user@Switch-1> show virtual-chassis vc-port fpc0: -------------------------------------------------------------------------Interface Type Trunk Status Speed Neighbor or ID (mbps) ID Interface PIC / Port vcp-0 Dedicated 2 Disabled 32000 vcp-1 Dedicated 1 Up 32000 1 vcp-1 ... {master:0} user@Switch-1> request virtual-chassis vc-port set interface vcp-0 {master:0} user@Switch-1> show virtual-chassis vc-port fpc0: -------------------------------------------------------------------------Interface Type Trunk Status Speed Neighbor or ID (mbps) ID Interface PIC / Port vcp-0 Dedicated 2 Down 32000 vcp-1 Dedicated 1 Up 32000 1 vcp-1 ... © 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-57
Verifying Status Information Use
show virtual-chassis status to view
Virtual Chassis status information: {master:0} user@Switch-1> show configuration virtual-chassis preprovisioned; member 0 { role routing-engine; serial-number BM0208105168; } member 1 { role line-card; serial-number BM0208124231; } {master:0} user@Switch-1> show virtual-chassis status Preprovisioned Virtual Chassis Virtual Chassis ID: 8d5c.a77f.8de8 Member ID 0 (FPC 0)
Status Prsnt
Mastership Serial No Model priority BM0208105168 ex4200-24t 129
Role Master*
1 (FPC 1)
Prsnt
BM0208124231 ex4200-24t
Linecard
© 2011 Juniper Networks, Inc. All r ights reserved.
0
Worldwide Education Services
Neighbor List ID Interface 1 vcp-0 1 vcp-1 0 vcp-0 0 vcp-1 www.junip er.net | 7-59
Summary In this chapter, we:
• Listed and described features that promote high availability • Configured and monitored high availability features • Described key concepts and components of a Virtual
Chassis • Explained the operational details of a Virtual Chassis • Implemented a Virtual Chassis and verified its operations
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-60
Review Questions 1. What is the purpose of LACP? 2. In what situation would you likely find RTG? 3. List some benefits of implementing a Virtual Chassis.
© 2011 Juniper Networks, Inc. All r ights reserved.
Worldwide Education Services
www.junip er.net | 7-61
Lab 7: Virtual Chassis Implement and verify operations of a Virtual Chassis.