Use of instruments
Frosi rosio o 17A Inspe spectio ction n work & equip quipm ment ent
slid slide e#1
Inspection Equipment
Utstyr utlagt
Frosi rosio o 17A Inspe spectio ction n work & equip quipm ment ent
slid slide e#2
Inspection after application After application the following must be checked y
Climatic
conditions (Ventilation,
Temperature and humidity) y
Curing
/ drying of the film
y
Dry fi fillm th thic ickn knes esss (D (DF FT)
y
Adhesion
y
Holi Ho lida day y de dete tect ctio ion n (i (iff re requ quir ired ed))
Frosi rosio o 17A Inspe spectio ction n work & equip quipm ment ent
slid slide e#3
ISO 2808 - 97 Method No.1 Wet film measuring comb
Microns 250
225 200 175 150 125 100
Wet 75
50
25
Steel
Frosio 17A Inspection work & equipment
slide # 4
paint
ISO 2808 Wet film thickness gauge Measure wet paint film Here: 25 microns between the teeth
0459-21
4932-81
Frosio 17A Inspection work & equipment
slide # 5
Using
³PIG´ Universal on a ship¶s hull PIG = Paint Inspection Gauge Destructive test method Possible to verify the number of coats applied Possible to measure the thickness of each individual coat
Frosio 17A Inspection work & equipment
Cd-4932-100
slide # 6
PIG Paint Inspection Gauge Mainly for laboratory use
4932-100
Frosio 17A Inspection work & equipment
slide # 7
ISO 2808 - 97
Determination of film thickness Method
No. 6:
Magnetic
method
Magnetic induction principle (Method 6 A) Permanent magnetic principle (Method 6 B) Instruments for magnetic, metallic substrates Calibration must be done in accordance with instructions from the manufacturer
Before testing the paint system must be properly cured. Frosio 17A Inspection work & equipment
slide # 8
ISO 2808 - 97
Determination of film thickness Method
No. 7 - Eddy current method
High frequency electromagnetic instrument For non-magnetic substrates Calibration in accordance with the manufacturers instruction
Frosio 17A Inspection work & equipment
slide # 9
ISO 2808 - 97
Determination of film thickness Method
No. 10 - On blast cleaned steel substrates
Electromagnetic instruments Calibration on a smooth stee l surface min. 1,2 mm thick For DFT measurement, not less than 25 and preferably above 50 microns Number of readings, as a guide: ± 1 reference area: At least 3 readings evenly ± 2 reference areas for every square meter for flat plates ± 4 reference areas for every length for a web ± 2 reference areas every metre length for a flange ± 2 reference areas every metre length for a pipe Frosio 17A Inspection work & equipment
slide # 10
ISO 2808 - Magnetic and electromagnetic Dry film thickness gauges Dry film thickness gauge Calibrate on smooth surface to zero and to thickness similar to be measured Check with your calibration foil frequently Plastic material foils wear easily. Replace frequently. No internal memory in gauge
Frosio 17A Inspection work & equipment
Cd-4932-82
slide # 11
ISO 2808 - Magnetic and electromagnetic Dry film thickness gauges Dry film thickness gauge Calibrate on smooth surface to zero and to thickness similar to be measured Check with your calibration foil frequently Plastic material foils wear easily. Replace frequently. No internal memory in gauge Inspection \ Dryfilmthickness1
Frosio 17A Inspection work & equipment
slide # 12
Magnetic and Electromagnetic Dry Film Thickness Gauges ISO 2808 Dry film thickness gauge Calibrate on smooth surface to zero and to thickness similar to be measured Check with your calibration foil frequently Plastic material foils wear easily. Replace frequently. Some models have internal memory.
Tørrfilm målere Elektr. Magn.
Frosio 17A Inspection work & equipment
slide # 13
SSPC - PA 2
Measuring DFT on small areas Procedure 1.
Area of 10 m2: 5 spot measurements
2.
Each spot measurement: The average of 3 individual readings made on one small area
3.
The average of 5 spot measurements must be within specified range of film thickness
4.
Single spot measurements may be as low as 80% of specified minimum film thickness
5.
Individual readings included in the spot measurements may be less than 80% of minimum thickness
Frosio 17A Inspection work & equipment
slide # 14
SSPC - PA 2
Number of film thickness measurements Case
Area
Selection of Measurements
1.
10 m2
5 spots (on each spot: 3 measurements)
2.
30 m2
As for case 1 for each 10 m 2
3. 4.
Up
to100 m2
Above 100 m2
Select 3 areas, each of 10 m 2 The first 100 m 2 as for case 3 For each following 100 m 2 select randomly one area of 10 m2
Note: If measurements outside the specification for any 10 m 2 in case 3 or 4 above are found, then each 10 m 2 shall be measured
Frosio 17A Inspection work & equipment
slide # 15
Instruments for measuring surface roughness
Stylus instruments Elcometer Mod. 123 Testex Press-O-film Microscope Comparator ±Rugotest No. 3 ±ISO 8503 etc.
Frosio 17A Inspection work & equipment
slide # 16
Surface Roughness acc. to ISO 8503 Example of a reference comparator: Clemco Surface profile comparator comprising four segments. Clemco - grit Clemco shot also available Check if the profile is according to specification and the paint manufacturer¶s recommendation
Clemco Compartor
Frosio 17A Inspection work & equipment
slide # 17
Using
Inspection Tools: Mirror and Flash light
Visu Visual al in inspec specttion Importan rtantt to tool ols s tto o be able to inspect areas difficult to access Jan,
Frosi rosio o 17A 17A Inspe nspect ctio ion n work ork & equi equip pmen ment
speil, lykt
slid slide e # 18
ISO ISO 850 8502 2 ± 4 Hum Humid idit ity y Guidance on the estim estimation ation of the probability of condensation prior to paint application 1. 2. 3. 4.
Air temperature % Relative hu humidity Steel temperature Dew point
Steel temperature min. 3 oC above the dew point
Frosi rosio o 17A 17A Inspe nspect ctio ion n work ork & equi equip pmen ment
slid slide e # 19
Contact Thermometer Ele Elect ctro roni nic c ins instr trum ume ent for measuring the steel temperature Steel temp tempe eratu rature re must be min. 3oC above the dew point Other types of thermometers are also available. E.g. magnetic thermometers
Steel temperature
Frosi rosio o 17A 17A Inspe nspect ctio ion n work ork & equi equip pmen ment
slid slide e # 20
Measuring the Relative Humidity ISO 8502 - 4 Photo: Sling hygrometer for measuring: - Dry temperature - Wet temperature Measure the temperature in the vicinity of the work Calculate the relative humidity Use together with dew point calculator
Frosio 17A Inspection work & equipment
slide # 21
Dew Point Calculator ISO 8502 - 4 For calculation of dew point To be used together with surface temperature thermometer and sling hygrometer. Use this frequently during pre-treatment, application and drying of the paint. Recommendation: Every 6 hours and when weather conditions are changing
Frosio 17A Inspection work & equipment
slide # 22
Salt Test Equipment - Bresle Test ISO 8502 - 6 (Sampling) ISO 8502 - 9 (Conductivity) Equipment for sampling and measuring content of water soluble salt on substrate Bresle method
Bresle sett
Frosio 17A Inspection work & equipment
slide # 23
How to measure the salt level on a surface Water soluble salts will be removed by water jetting Here: The substrate is cleaned at a pressure of 2000 bar Salt level is measured by the Bresle method Dissolve the salt inside the frame of the patch Measure the conductivity of the water sample
For 15 ml sample size, multiply conductivity measured in S by a factor of 6 to get mg salt per m2 Pre-treatment: Wj_saltlevel1
Frosio 17A Inspection work & equipment
slide # 24
Calculating salt level on the substrate Formula:
(L2 ± L1) x 6 = mg sa lt per m2
L2
= S after cleaning
L1
= S before cleaning
Water sample, ml:
10
15
20
50
Constant in formula: 4
6
8
20
Frosio 17A Inspection work & equipment
slide # 25
Assessment of Dust on Steel Surfaces Prepared for Painting. ISO 8502-3
Tape
Blast cleaned steel
Approved Not approved
Frosio 17A Inspection work & equipment
slide # 26
Frosio 17A Inspection work & equipment
slide # 27
ASTM D 4752-87
Curing test of Zinc - ethylsilicate with MEK.
Glove
Rag
MEK
Rubbing 50 x
No Zinc on the Rag: Cured Approved
A lot of Zinc on Rag: Not cured Further curing / Reblasting
Frosio 17A Inspection work & equipment
slide # 28
ASTM D 4752-87 MEK curing test of zinc ethyl silicate Left: One cured and uncured test plate Right: Uncured zinc over coated. Result: Delamination
0807-2
A-4
Frosio 17A Inspection work & equipment
slide # 29
ASTM D 47524752 -87
Curing test of Zinc ± ± ethyl silicate with MEK. Glove
MEK
Rag
Inspection /
Frosio 17A Inspection work & equipment
Zincsilicate_curing1
slide # 30
ASTM D 3359-87 Adhesion testing by knife and adhesive tape
There are two test methods The method to select depends on the DFT Method A: DFT above 125 microns Method B: DFT below 125 microns (Above 125 if wider cuts are used) Method A: X - cut. Tape test Method B: Cross - cut. Tape test
Frosio 17A Inspection work & equipment
slide # 31
ASTM 3359-87.
Method B
Adhesion testing < 50 microns = 1 mm apart (11 cuts) 50 - 125 microns = 2 mm apart (6 cuts) > 125 microns = Method A 1. 2. 3. 4. 5. 6. 7.
Cuts: 20 mm long Brush with a soft brush Examine Cuts: 20 mm long at 90o on the original cuts Brush with... Tape 75 mm Within 90 + 30 sec. remove tape
Frosio 17A Inspection work & equipment
slide # 32
Classification of adhesion test results. Method B. (Example for six parallel cuts). 5B
None
4B
3B
2B
1B
0B
Greater
than 6 5%
5B The edges of the cuts are completely smooth; none of the lattice is detached 4B Small flakes of the coating is detached at intersections: 5% of the area is affected 3B Small flakes of the coating are detached along edges and at intersections of cuts. The area affected is 5 to 15% of the lattice. 2B The coating has flaked along the edges and on parts of the squares. The area affected is 15 to 35% of the lattice. 1B The coating has flaked along the edges of cuts in large ribbons and whole squares have detached. The area affected is 35 to 65 % of the lattice. 0B Flaking and detachment worse than Grade 1B.
Frosio 17A Inspection work & equipment
slide # 33
ISO 2409
Cross-cut test Cutting
tool Single bladed knife or Multi-blade cutting tool with 6 cutting edges spaced 1 mm or 2 mm apart
Spacing of cuts 0 - 60 microns: 0 - 60 microns: 60 - 120 microns: 121 - 250 microns:
1 2 3 3
mm mm mm mm
spacing, spacing, spacing, spacing,
Frosio 17A Inspection work & equipment
hard substrates soft substrates hard/soft substrates hard/soft substrates
slide # 34
ISO 2409
Cross-cut test Procedure: Make 6 parallel cuts with defined space in the coating. Repeat operation, crossing original cuts at 90o so that a grid pattern is formed. Brush with soft brush. Apply adhesive tape and pull off. Classify results in accordance with table 1.
Frosio 17A Inspection work & equipment
slide # 35
ISO 2409 Cross cut adhesion test Cross cut adhesion test Cut vertical and horizontal lines to form a grid Apply a strong tape Pull off the tape Evaluate according to the standard
Frosio 17A Inspection work & equipment
Cd-4932-91
slide # 36
ISO 2409 Cross-cut adhesion test Left: A good type of cross-cut tool Right: Evaluation of performed test
0002-002
0002-001
Frosio 17A Inspection work & equipment
slide # 37
Classification of Adhesion Test Results. (Example for six parallel cuts). 5B
None
4B
3B
2B
1B
0B
Greater
than 6 5%
5B The edges of the cuts are completely smooth; none of the lattice is detached 4B Small flakes of the coating is detached at intersections: 5% of the area is affected 3B Small flakes of the coating are detached along edges and at intersections of cuts. The area affected is 5 to 15% of the lattice. 2B The coating has flaked along the edges and on parts of the squares. The area affected is 15 to 35% of the lattice. 1B The coating has flaked along the edges of cuts in large ribbons and whole squares have detached. The area affected is 35 to 65 % of the lattice. 0B Flaking and detachment worse than Grade 1B.
Frosio 17A Inspection work & equipment
slide # 38
ISO 2409 Classification of Cross-cut test Classi-
fication 0 1
Appearance of surface Six parallel cuts
Description Completely
smooth: none of the squares detached Small flakes at the Intersections. Area affected 5 %
2
Flaked along the edges and/or at the Intersections. Area affected: 5-15%
3
Flaked along the edges, wholly in large ribbons, and/or partly or wholly on different parts of the squares. Area affected: 15-35%
4
Flaked along the edges in large ribbons and/or some squares have detached partly or wholly. Area affected: 35-65%
5
Any degree of flaking that cannot even be classified by 4. Frosio 17A Inspection work & equipment
slide # 39
ISO 2409 Cross cut adhesion test Cross cut adhesion test Cut vertical and horizontal lines to form a grid Apply a strong tape Pull off the tape Evaluate according to the standard
Inspection /
Frosio 17A Inspection work & equipment
slide # 40
Adhesion_crosscut1
ISO 4624
Pull-off test for adhesion Instruments:
Elcometer Adhesion Tester Saeberg Adhesion Tester (pneumatic) Hate Adhesion Tester (hydraulic) PAT Other
Failure:
Adhesion failure: Between coats or between or substrate and 1st coat Cohesion failure: Inside a coat
Frosio 17A Inspection work & equipment
slide # 41
ISO 4624
Pull-off test for adhesion Procedure :
Test dollies glued onto the coating Adhesive: Cyano-acrylate or solvent free epoxy Remove adhesive and coating around the dollies Pull off test-dollies vertical to the surface Read adhesion value and report the type of fracture
Fractures: Adhesion failure - fracture between coats or substrate and 1. coat Cohesion failure - fracture within a coat
Frosio 17A Inspection work & equipment
slide # 42
ISO 4624 Pull-off dollies glued to the structure Pull off adhesion test Dollies are glued to the structure with a strong glue Prior to pull-off: Cut around the dolly, through the paint film and down to the substrate material Frosio 17A Inspection work & equipment
Cd-4932-102
slide # 43
ISO 4624 Pull-off testing of paint on a structure Pull off adhesion test. Destructive test method Here, connecting of the device for pulling off the dollies Read and note the value Several types of instruments are available
Frosio 17A Inspection work & equipment
Cd-4932-101
slide # 44
ISO 4624 Area after pull-off testing Pull off adhesion test The adhesive failure fracture between coats or between coating and substrate must be evaluated Note adhesion failure, % The cohesive failure fracture within the coating- must be evaluated. Note cohesion failure, % Also: Note glue failure, %
Frosio 17A Inspection work & equipment
Cd-4932-103
slide # 45
ISO 4624 Pull-off dollies glued to the structure Pull off adhesion test Dollies are glued to the structure with a strong glue Prior to pull-off: Cut around the dolly, through the paint film and down to the substrate material Record the pull-off value Evaluate the failure Frosio 17A Inspection work & equipment
Inspection / Adhesion_pulloff1
slide # 46
ASTM G 62 - 85 Method A
Pinhole detection.
Low
voltage.
Low voltage: < 75 V DC To detect pinholes, voids or metal particles to be in the range of 25-250 microns. Effective for paint films up to a DFT of 500 microns if a wetting agent is used in the water. This is a non-destructive test.
Frosio 17A Inspection work & equipment
slide # 47
ASTM G-62-85, method A Low voltage holiday detector Photo: Low voltage pinhole detector Detecting pinholes, voids or metal particles in paint film up to 250 microns Non destructive test method Will only detect defects down to bare metal The sponge must be wetted Do not use excessive water Frosio 17A Inspection work & equipment
Cd-4932-92
slide # 48
ASTM G-62-85, method A Low voltage pinhole detector Photo: Low voltage pinhole detector Detecting pinholes, voids or metal particles in paint film up to 250 microns Non destructive test method Will only detect defects down to bare metal The sponge must be wetted Do not use excessive water
0002-004
Frosio 17A Inspection work & equipment
slide # 49
ASTM G-62-85, method A Low voltage pinhole detector Detecting pinholes, voids or metal particles in paint film up to 250 microns Non destructive test method Will only detect defects down to bare metal The sponge must be wetted Do not use excessive water Frosio 17A Inspection work & equipment
Inspection
slide # 50
/ Pore_detection1
ASTM G 62 Method B
Holiday detection. High voltage:
High
voltage.
900 - 20.000 V
Used to detect pinholes, voids and areas with thin paint films This is a destructive test.
Frosio 17A Inspection work & equipment
slide # 51
ASTM G-62-85, method B High voltage holiday detector
Destructive
test method for detecting pinholes, voids and thin spots in paint film Adjust voltage according to the film thickness or the paint manufacturers recommendation Gives a light or signal when pinhole or weak point is detected
Frosio 17A Inspection work & equipment
Cd-4932-93
slide # 52
ASTM G-62-85, method B High voltage holiday detector
Destructive
test method for detecting pinholes, voids and thin spots in paint film Adjust voltage according to the film thickness or the paint manufacturers recommendation Gives a light or signal when pinhole or weak point is detected
0002-005
Frosio 17A Inspection work & equipment
slide # 53
ASTM G 62 Method B
Holiday detection.
High voltage: 900 - 20.000 V
Used
to detect pinholes, voids and areas with thin paint films
This is a destructive test.
High
voltage.
Inspection /
Frosio 17A Inspection work & equipment
Holiday_detection1
slide # 54
ISO 12944
General standard for corrosion protection: Paints
and varnishes - Corrosion protection of steel structures by protective paints systems. Part 1 Part 2 Part 3 Part 4 Part 5 Part
6 Part 7 Part 8
General introduction. Classification of environments. Design considerations. Types of surface and surface preparation. Protective paint systems. Laboratory performance test methods. Execution and supervision of paint work. Development of specifications for new work and maintenance.
Frosio 17A Inspection work & equipment
slide # 55
ISO 8504 - 1
General principles
Selection of methods
Frosio 17A Inspection work & equipment
slide # 56
ISO 8504
Surface preparation methods:
Part 1:
General principles. Part 2: Abrasive blast-cleaning. Part 3: Hand- and power-tool cleaning.
Frosio 17A Inspection work & equipment
slide # 57
ISO 8504 - 2
Abrasive blast-cleaning
Methods Effectiveness Fields of application
Frosio 17A Inspection work & equipment
slide # 58
ISO 8504 - 3
Hand and Power-tool Cleaning
Methods Equipment to be used Procedure to be followed
Frosio 17A Inspection work & equipment
slide # 59
Using
solvents to determine generic type of paint Paint dissolves: Physically drying
Rag soaked with solvent
No reaction: Chemically curing
Steel
2
Lifting/Wrinkling: Oxidatively curing
coat paint
Frosio 17A Inspection work & equipment
slide # 60
Using
solvents to determine generic type of paint Use a rag soaked with solvent No reaction: Chemically curing Paint dissolves: Physically drying Lifting/Wrinkling:
Inspection /
Oxidatively curing Frosio 17A Inspection work & equipment
slide # 61
Determine_generic1
Standards relating to mechanical properties Property
Standard / Test method
Adhesion (Cross cut) Adhesion (Pull-off)
ISO 2409, DIN 53251, BS 3900-E6, ASTM 3359 ISO 4624, ASTM 4541, BS 3900 - E10
Adhesion (Shear strength)
ASTM D 1002 (Specified for Chartek)
Hardness
ISO 2815
(Buchholz - methode)
Hardness Hardness Elasticiy
ISO 1522 (K ønig - pendel) Barchol ISO 1520 (Cupping test)
Flexibility
ISO 6860 ASTM D 522 BS 3900 - E11 (Conical mandrel)
Impact resistance
ISO/TR 6272 - 79E
ASTM D 2794 - 84
DIN 55669
BS 3900 - E3
Frosio 17A Inspection work & equipment
slide # 62
Testing and evaluation. marine atmosphere (1 of 2) Test method Physical
Standards
Comments
ISO 2409 ISO 4624 ISO 1510 ISO 1520 ISO 2815 ISO 6272 ISO 2813 ASTM D 4060
Before and after exposure Before and after exposure Before and after exposure Before and after exposure
testing
Adhesion Adhesion Flexibility Elasticity Hardness Impact resistance Gloss Abrasion resistance
Exposure conditions: Saltspray Prohesion test UV-cabinet Condensation chamber Humidity chamber Weathering Resistance to liquids
ISO 7253 or ASTM B 117 ASTM G 53 ISO 6270 BS 3900 ISO 2810 ISO 2812
Frosio 17A Inspection work & equipment
Oil,
petroleum , etc.
slide # 63
Testing and evaluation. marine atmosphere (2 of 2) Test method
Standards
Comments
Evaluation of paint films Blistering Rust Cracking Flaking Chalking Scribe
ISO 4628/2 ISO 4628/3 ISO 4628/4 ISO 4628/5 ISO 4628/6 ASTM D 1654
Evaluation of the liquid paint Appearance in tin
ISO 2431
Viscosity
ISO 2884
³Flow
Application properties
Frosio 17A Inspection work & equipment
slide # 64
time´
Abrasion resistance Weigh the painted sample Install it in the apparatus and run 1000 cycles Measure the weight loss
Testing paints \ Abrasion resistance1
Frosio 17A Inspection work & equipment
slide # 65
Flexibility test Use a thin test panel Measure the paint film thickness Carry out the impact test on the rear side of the test panel Determine the highest level of impact load before any crack or defect in the paint film occurs Testing paints \ Flexibility_test1
Frosio 17A Inspection work & equipment
slide # 66
Impact test Use a thick test panel Measure the paint film thickness Carry out the impact test on the painted side of the test panel Determine the highest level of impact load before any crack or defect in the paint film occurs Testing paints \ Impact_test1
Frosio 17A Inspection work & equipment
slide # 67
Reference area should: be representative to the remaining area coated with the same system. be available for inspection at any time. be marked thoroughly to indicate "ref.area" not be overcoated
Frosio 17A Inspection work & equipment
slide # 68
Controlled application Inspection of: » » » » » »
steelwork cleaning surface preparation (blastcleaning) painting curing completed system
Frosio 17A Inspection work & equipment
slide # 69