Forcibly Software Loading Procedure (Applicable For BTS3900 and BTS3900A)
Prepared by: Md. Abdullah-Al-Mamun Staff ID: 00718390
Contents
Starting the Site Maintenance Terminal System Locally Logging In to the BTS Forcibly Loading Software of GTMU Activating Software of GTMU Site Opstart Adding DRFU Software Loading of DRFU Activating Software of DRFU Troubleshooting case
2009-05-06
HUAWEI Confidential
Page1, Total16
Document Title
Security Level:
Starting the Site Maintenance Terminal System Before starting the Site Maintenance Terminal, firstly, set the IP address of the Site Maintenance Terminal PC; secondly, connect the Site Maintenance Terminal PC to the BTS; finally, log in to the Site Maintenance Terminal.
Setting the IP Address of the Site Maintenance Terminal PC 1. Windows XP operating system as an example. On the Windows XP operating system, choose Start > Control Panel. 2. Select Network Connections. A dialog box is displayed. Right-click the Local Area Connection icon. 3. Choose Properties on the shortcut menu,. The Local Area Connection Properties dialog box is displayed. 4. Select Internet Protocol (TCP/IP). 5. Click Properties. The Internet Protocol (TCP/IP) Properties dialog box is displayed. 6. Select Use the following IP address. 7. Enter the correct IP address, subnet mask, and default gateway. Ensure that the IP address of the Site Maintenance Terminal PC and the IP address (192.168.0.72/255.255.255.0) of the BTS are located in the same network segment, so that a local maintenance path can be set up. 8. Click OK to complete the setting.
2009-05-06
HUAWEI Confidential
Page2, Total16
Document Title
Security Level:
Locally Logging In to the BTS We can run the Site Maintenance Terminal to directly log in to the BTS.
Prerequisites • The Site Maintenance Terminal PC is connected properly to the BTS. • The Site Maintenance Terminal PC is installed with the latest site maintenance terminal software. Procedure 1. Double-click btsm.exe to start the Site Maintenance Terminal System. If the communication between the Site Maintenance Terminal PC and the BTS is not set up, the Communication failed dialog box is displayed, as shown in figure.
2. Click Yes. The Set Communication Port Parameter dialog box is displayed, as shown in figure
3. In the Select Communication Port area, click Network Port. In the Configure IP area, set the IP address to 192.168.0.72.
2009-05-06
HUAWEI Confidential
Page3, Total16
Document Title
Security Level:
4. Click OK. The Site Maintenance Terminal System window is displayed, as shown in Figure
5. On the Site Maintence Terminal System, choose User and then Login. Enter User Name (Omc by default) and User Password (omc by default) to log in.
2009-05-06
HUAWEI Confidential
Page4, Total16
Document Title
Security Level:
6. In maintenance console, select the BTS to be maintained, and then press F5. A box for entering the operation passwords appears at the top of the window. Enter cf + hours (24 hour). If the current time of the system is 14:32, enter cf14. If the times 9:00am enter cf09, then press Enter.
7. The following Window will displayed with more function
2009-05-06
HUAWEI Confidential
Page5, Total16
Document Title
Security Level:
8. Get Site Management Right. Click OK of the Message box.
Forcibly Loading Software of GTMU 1. This function is performed to load software to the main control board. The main control board of the base station is the GTMU. Select Site0 > Double Click the Function Forced Software Load. In the dialog box Browse the required File for GTMU i.e. gtmudown.pck. Enter the latest Version and File ID: GTMU_MAIN. Then Click Start….
2009-05-06
HUAWEI Confidential
Page6, Total16
Document Title
Security Level:
2. We can view the loading progress in the Site Maintenance Terminal System. If the software is loaded successfully, the Loading software successfully message is displayed on the status bar.
Activating Software of GTMU NOTE: Once Software Loading complete wait approximate 2 minute then start Activating Software. 1. Select Site0 > Double Click the Function Software Activation. The dialog box is displayed. In the Version area, enter the version number. In the File ID drop-down list, select the file ID, as shown in figure
2009-05-06
HUAWEI Confidential
Page7, Total16
Document Title
Security Level:
2. Click OK. The Software activation successfully message is displayed on the status bar at the bottom of the dialog box.
3. Make sure from the Board Information of GTMU that the loaded Software Version is correct.
2009-05-06
HUAWEI Confidential
Page8, Total16
Document Title
Security Level:
Site Opstart 1. Select Site0 > Double Click the Function Site Opstart.The dialog box is displayed. Click OK.
2. The Site Opstart successfully message is displayed on the status bar at the bottom of the dialog box.
2009-05-06
HUAWEI Confidential
Page9, Total16
Document Title
Security Level:
Adding DRFU 1. In the left pane of the Site Maintenance Terminal System window, select Board. In the right pane of the window, double-click Board Configuration. The Board Configuration window is displayed Double Click on GTMU. Then Topology Configuration window is displayed as shown in figure.
2. Collect Topology info first. Click ADD RRU. Deploy DRRU window is displayed enter Card Type; card No, SFP No and Hop No.
2009-05-06
HUAWEI Confidential
Page10, Total16
Document Title
Security Level:
3. The following example for Single Band (900MHz): TRX configuration 4/4/4.
DRFU Position in Topology config (4/4/4)_ 900MHz
4. The following example for Duel Band (900 MHz and 1800MHz) 4/4/4 + 4/4/4 Topology configuration:
DRFU0 & DRFU1_900 DRFU6 & DRFU7_1800 DRFU2 & DRFU3_900 DRFU8 & DRFU9_1800 DRFU4 & DRFU5_900 DRFU10 & DRFU11_1800
2009-05-06
HUAWEI Confidential
Page11, Total16
Document Title
Security Level:
5. DRFU position info details in Topology configuration:
DRFU0 & DRFU1_900
DRFU6 & DRFU7_1800
DRFU2 & DRFU3_900
DRFU8 & DRFU9_1800
DRFU4 & DRFU5_900
DRFU10 & DRFU11_1800
2009-05-06
HUAWEI Confidential
Page12, Total16
Document Title
Security Level:
Software Loading of DRFU 1. Once DRFU adding complete then Select Site0 > Double Click the Function Forced Software Load. In the dialog box Browse the required File for DRFU i.e. drfudown.pck. Enter the latest Version and File ID: DRFU_MAIN. Then Click Start….
2. We can view the loading progress in the Site Maintenance Terminal System. If the software is loaded successfully, the Loading software successfully message is displayed on the status bar.
2009-05-06
HUAWEI Confidential
Page13, Total16
Document Title
Security Level:
Activating Software of DRFU 1. Select Site0 > Double Click the Function Software Activation. The dialog box is displayed. DRFU board downloading progress % message is displayed on the status bar at the bottom of the dialog box. So DRFU software activation starts automatically once loading complete successfully. There are no specified sequences for activating the software of the boards.
2. Note it will take long time. So have to wait until all DRFU’s loading complete. Once any DRFU downloading progress 100% complete, check the respective DRFU Board Information the version correct or not.
2009-05-06
HUAWEI Confidential
Page14, Total16
Document Title
Security Level:
Troubleshooting case 1 Phenomenon Description: Even though GTMU software loading completed successfully the Version still not updated.
Suggestions and Summary: This is occurred due to Execute the function Software Activation without waiting few minutes (approx 2 min) after Loading Software Successfully. So have to wait few minutes once loading Software Successfully.
2009-05-06
HUAWEI Confidential
Page15, Total16
Document Title
Security Level:
Troubleshooting case 2 Phenomenon Description: Even DRFU Software activation in progress but not completed 100% and immediately takes other DRFU and continue activation progress. Suggestions and Summary: Check how many DRFU failed to update the version and Start the Software Activation process for those DRFU separately. Select Site0 > Double Click the Function Software Activation. The dialog box is displayed. In the dialog box Enter the latest Version, Board No. and File ID: DRFU_MAIN. Then Click OK.
Troubleshooting case 3 Phenomenon Description: During the activation of the DRFU board software, if the Site Maintenance Terminal prompts that the software activation failed. Suggestions and Summary: Check the communication between the BBU and the DRFU. 1. Check the status of the CPRI0 LED on the GTMU panel of the BBU and the status of the CPRI0 and CPRI1 LEDs on the DRFU panel. All the LEDs are in the on in green status. (The status of the LED corresponding to the CPRI port that is not in use should be Off.) 2. Check that the signal cables between cascaded DRFUs are securely connected to the CPRI0 and CPRI1 ports. 3. Check that one end of the CPRI signal cable is securely connected to the CPRI0 port on the DRFU and the other end is securely connected to the CPRI port on the BBU. 4. Check the SFP male connectors at both ends of the CPRI signal cable. If the connector is faulty, replace it.