Manual de Configuração para exteriorização de alarmes para gabinetes eltek e equipamentos 2g tipo nokiaDescripción completa
agilent dso user manual
Guia de inicio rapido para sistemas de visión KEYENCEDescripción completa
Descrição: W10 DS
Rectifier 1 phasaFull description
Descripción: Eltek FP2 commissioning
Physics Class 12th Project Report on Half Wave Rectifier
Descripción completa
Manual de usuario de rectificador Eltek Flatpack
Full description
jbvhDescripción completa
fgg
DC rectifier systems
Full description
Full description
C a s s e t t e / R a c k
AC/DC Rectifiers
5 600W
X Seri Series es - Front end prod products ucts
Features • 180V 180VAC AC to 264VA 264VACC input input • Up to to 92% effici efficiency ency • Powe Powerr factor factor correctio correctionn • Hot plu plugga ggable ble • Fron Frontt panel LED LED indicators indicators • 12C Serical Serical communicat communications ions bus bus • AC and and DC fail fail alarm alarm • Overt Overtemper emperature ature alarm
Specifications INPUT Universal AC Frequency Current Inrush current Power factor DC input versions OUTPUT Voltage Sink current Regulation Current Current limit setpoint Short circuit current Noise
316
180-264VAC. 47-63Hz. See table. 30A peak. .99 @ typ @ 230VAC, full load. See table.
Rise time Dynamic response Turn on delay Load sharing Reverse output current Efficiency
12V. 100mA. ±1%. See table. See table. See table. 40mV rms typ (10kHz to 20MHz). 30 dBrnc (measured without external battery). 150mV p-p (10kHz to 20Mhz). 400msec max. 3% max. 3.5 sec max. ±5% of full load. 0.5A. 90-92% depending on output voltage.
ENVIRONMENTAL Ope pera rati ting ng tem empe pera ratu turre Storage te temperature
See tab able le.. –40°C to to +8 +85°C.
GENERAL Dimensions Weight
404.8 x 81.3 x 131.5 mm. 6.8 kg.
STANDARDS Safety standard EMI/EMC Cond Co nduc uctitive ve Em Emis issi sion onss NEBS
IEEE-C62.41 EN61000-3-2 EN61000-3-3 EN61000-4-2
EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 CE
EN60950, UL60950/UL1801. Conforms to EN55022, Level B. EN55 EN 5502 022, 2, Le Leve vell B & FCC FCC Cl Clas asss B EMC, Surge Standards, and Electrical Safety per GR1089-CORE. IEEE Recommended Practice on Surge Voltages in Low-Voltage Low-Vo ltage AC. Power Circuits. Category A2. Limits fo for ha harmonic cu current em emissions fo for cl class D equipment. Limits fo for vo voltage flfluctuations an and flflicker in in lo low-voltage systems. Electrostatic di discharge immunity te test. Le Level 4. 4. All us user accessible ports. Damage free, operational and nonoperational. Criterion B. Radiated, radio-frequency, electromagnetic field immunity test. Level 3: 10 V/m. Electrical fa fast transient/burst immunity test. Level 4 Surge immunity test. Installation Class 4. 6 kV: Line to Line, Criterion A. 6 kV: Line to Ground, Criterion A. RF Common Mode. Level 3, Criterion A. Magnetic Field. Level 3, Criterion A. Voltage dips, short interruptions and voltage variations. Yes, meets 73/23/EEC and 93/68/EEC directives.