Eltek Valere Telecom Product Overview > January 2010
A Full Line of DC Power Systems > Broadest Industry Product Offering •
Everything from 5 amps to 10,000 amps
> Highest Performance •
High efficiency, high density
Minipack 1U/1,6kW 2U/4,8kW
Compact Systems 2U/7,5kW
FP 2 2U/8kW 6U/8-24kW
FP 2 48-280kW
PP 5,8 54-550kW
Scalable 100-1000kW
Micropack 2U/1kW Small
Slide 2 15/11/2010
Medium
Large
Leading edge Rectifier Modules > Power from 250W to 11KW per module > Designed for harsh environments > Efficiency >96%!
Powerpack 3ph/5800W
Powerpack 3ph/11000W
FP 2 2000-3000W V-Series 1000-2500 W Minipack 400 & 800W Micropack 250W Small
Slide 3 15/11/2010
Medium
LargeC
Smartpa Sma rtpack ck – More than than just a contr controller oller > Scalable controller for systems based on all new and future rectifier families
Rectifiers Smartpack
> Configuration and monitoring •
Front panel
•
WEB
•
Windows SW
> Basic integrated I/O meeting average system requirements > Designed for flexibility and future growth
Slide 4 15/11/2010
N A C
N A C
Smartnode
Battery String Monitor
Smartpa Sma rtpack ck – More than than just a contr controller oller >
Full remote control via: •
• •
>
Comprehensive Battery Management • • • • •
>
Thermal compensation Battery disconnection preventing deep discharge Multi level load shedding Charge control, current and voltage Battery life time prediction
Hybrid solar features • • • •
Slide 5 15/11/2010
Ethernet using standard WEB Browser or EltekValere Windows SW and email alert functionality Modem using alarm alarm “call back” and SMS alert/status report functionality Ethernet based closed private networks using Network Management Systems with SNMP
Generator control (cyclic charging) for reduced fuel consumption Reduced charge current limitation when running gen-sets Startup delay of rectifiers Logging of energy produced from PV panel, genset and other sources
>
Efficiency Management • • • •
>
Manages system system to ‘target’ efficiency Rectifiers disabled based on system load Rectifiers are shuffled to maximize lifetime N+1 redundancy kept as default, but can be removed
Other features • • • • • • • • • •
Multi language menu choice Major and minor alarm trigger levels on all monitors PLC functionality triggering of event trough Boolean functions Battery & load fuse monitoring Mains supervision Event log (10.000 alarms and events) Interval data logging of selected monitors Average and peak peak values values of all monitors Detailed rectifier inventory with internal monitoring Adjustable Adjustable rectifier rectifier ”walk-in”
Smartpa Sma rtpack ck – More than than just a contr controller oller > Additional functionality functionality by optional CAN nodes nodes Battery Monitor
Load Monitor
• Additional monitoring monitoring of battery fuse, temperature, block voltage & current per string
• Additional monitoring monitoring of 8 individual load breakers and currents
I/OMonitor • Additional monitoring monitoring of 6 aux. inputs and 6 extra output relays • 2 temperature probe inputs • 2 Analogue outputs • 2 tacho input readings
Slide 6 15/11/2010
Smartnode RS-232/RS-485 • •
Communication with equipment with proprietary protocols Modem “call-back” “call-back” and SMS feature with GSM modems
Standard Building blocks Outdoor Enclosures
Power modules
Optional kits
SPD
Power Cores
AC distribution kit
Battery string monitoring Battery shelf kit
Indoor Enclosures Additional I&O
Batteries
Slide 7 15/11/2010
CTO – Con Config figure ure To Order Order
Integrated
Indoor cabinet
Tailor-made systems combining standard building blocs Slide 8 15/11/2010
Outdoor cabinet
CTO – Con Config figure ure To Order Order
BOM
Configurator
Slide 9 15/11/2010
Order Office/Logistics
ERP
Manufacturing site
Telecom Product Families Ø
Micropack Minipack Flatpack2 Powerpack Cabinets Remote Power System
Slide 10 15/11/2010
Micropack Rectifier
Acronyms
48V / 250W
(241120.100)
24V / 240W
(241120.200)
12V / 120W
(241120.300)
150mm
Main Characteristics 88mm “2U”
44mm “1U”
Slide 11 15/11/2010
>
Convection-cooled
>
Integrated module alarm
>
Wide AC range
>
CAN Bus communication
(no internal fans)
Micropack Stand-alone
Acronyms
44 mm
Stand-alone Power Core Card (241120.900) 150 mm
134 mm
Main Characteristics
88 mm
Slide 12 15/11/2010
>
Single AC feed
>
1 x alarm output
>
Bulk feed DC out
>
DIN mounted solution
Micropack Controller
Acronyms
Compack
(241120.400)
110 mm
Main Characteristics >
CAN Bus communication
>
User connects via Ethernet port
>
2 x LVD operation support
>
3 x pot. free alarm contacts
>
Supports CAN nodes
70 mm
30 mm
Slide 13 15/11/2010
Micropack Integrated System 2 or 4 module positions > Max 500W or 1000W > Compack controller > Load distribution modules, each with 4x plug in breaker positions > Battery breaker module with 2xBattery MCB, current measurement and LVBD > Optional Bulk-feed module -48V
-48V
> Optional Optional 19” bracket bracket
Batt. dist. module 241120.910
Slide 14 15/11/2010
Load. dist. module 241120.920
Bulk feed module 241120.911
Telecom Product Families Micropack Ø
Minipack Flatpack2 Powerpack Cabinets Remote Power System
Slide 15 15/11/2010
Minipack Rectifiers
Acronyms
48V / 400W
250mm
(241117.120)
48V / 800W WIR
(241117.130)
Main Characteristics 88.9mm “2U”
42.5mm “1U”
Slide 16 15/11/2010
>
Front-to-rear Front-to-rear Airflow
>
Under-wiring Bus
>
Wide AC range
>
CAN Bus communication
Smartpack Controller
Acronyms
Smartpack Extended (242100.110)
144 mm
Smartpack RS-232 Front (242100.111) 43 mm “1U”
Smartpack GB RS-232 Front (242100.114)
109 mm
Smartpack WEB/SNMP 6+6 (242100.118)
Main Characteristics
Slide 17 15/11/2010
>
CAN Bus communication
>
LCD screen and keypad
>
User connects via USB
>
Supports CAN nodes
(Chinese) Chinese)
Minipac Mini pack k Integrat Integrated ed System System – 2U
> 48V/3200W
Slide 18 15/11/2010
> 48V/4800W
•
Up to 4 Rectifiers
•
Up to 6 Rectifiers
•
SmartPack
•
SmartPack
•
Max 10 MCB, (2-30A plug-in breakers)
•
Max 8 MCB, (2-30A plug-in breakers)
•
Max 2 x 60A BB
•
Max 2 x 100A BB
•
LVBD
•
LVBD
•
Optional LVLD
•
Optional LVLD
•
Bulk-feed options
•
Bulk-feed options
Acronyms
Minipack 1U Controller
Acronyms
Compack
(241120.400)
110 mm
Main Characteristics >
CAN Bus communication
>
User connects via Ethernet port
>
2 x LVD operation support
>
3 x pot. free alarm contacts
>
Supports CAN nodes
70 mm
30 mm
Slide 19 15/11/2010
Minipac Mini pack k Integrat Integrated ed System System – 1U
> Bulk feed • •
Slide 20 15/11/2010
Pure DC power power supply – AC in 48V DC DC out, no DC distribution
> DC Distribution •
Optional controller, Compack, for remote monitoring
Integrated DC distribution: -
6 x load fuses, (max. 10A)
-
2 x battery breakers, plug-in type, max 30A
-
Low volt disconnection
-
Fuse monitoring
•
Battery management included temp. compensated charging, automatic or manual battery testing, low volt disconnection, etc.
•
Controller (Compack) for full remote remote monitoring via WEB and traditional alarm contacts
Telecom Product Families Micropack Minipack Ø
Flatpack2 Powerpack Cabinets Remote Power System
Slide 21 15/11/2010
Flatpack2 Rectifiers Standard range 3 2 7 m m
41,5 mm
Acronyms
48V / 2000W
(241115.100)
48V / 2000W B-F
(241115.120)
24V / 2000W WOR
(241115.250)
48V / 3000W
(241119.100)
“1U”
10 9 mm 94
Main Characteristics >
Fan cooled
>
Rear edge-connect
>
Wide AC range
) 92 % ( . f f E
Max Efficiency Zone
90
88 0
Slide 22 15/11/2010
400
800
1200 Pout(W)
1600
2000
Flatpack2 Rectifiers HE range
Acronyms
48V / 2000W
(241115.105)
48V / 3000W
(241119.105)
24V / 1800W
(241115.205)
Main Characteristics
Slide 23 15/11/2010
>
>96% efficiency !!
>
Only 1 FAN
>
100% plug compatible with standard range
(less noise)
96%
95%
Flatpack2 HE Solar Solar Charger Features >
Maximum Power Point Tracking
>
Galvanic isolation
>
Supported by current Smartpacks
Main Characteristics
48V / 1500W
>
Uses same PR as FP2 rectifier
>
Input voltage (tolerance) : 170 170 – 265 VDC VDC
(241115.650) Typical input feed is from one string of between 4 to 6 solar panels
Slide 24 15/11/2010
Flatpack2 Solar Hybrid concept Solar
Load Battery Monitoring*
Solar Batteries
ü
Same modular philosophy as for AC/DC
ü
Common Smartpack control system
ü
Galvanic isolation between panels and
CAN bus Smartpack
~ Mains
I/O* Unit
telecom equipment improves immunity to
Remote Monitoring*
lightning transients
ü
HE technology, 96% efficiency
ü
Maximum Power Point Tracking utilizes
Gen set
*optional
Slide 25 15/11/2010
close to 100% of available solar power Fuel tank
Flatpack2 Flatp ack2 Stan Stand-alo d-alone ne box - DNV
Acronyms
Part number : M20101.000 Suit most Std and HE Flatpack2 rectifiers
(see datasheet for details)
Main Characteristics
Rear view
Slide 26 15/11/2010
>
DNV Approved
>
In-Built alarm monitoring
>
Can work in parallel
>
CAN Bus communication
Smartpack Controller
Acronyms
Smartpack Extended (242100.110)
144 mm
Smartpack RS-232 Front (242100.111) 43 mm “1U”
Smartpack GB RS-232 Front (242100.114)
109 mm
Smartpack WEB/SNMP 6+6 (242100.118)
Main Characteristics
Slide 27 15/11/2010
>
CAN Bus communication
>
LCD screen and keypad
>
User connects via USB
>
Supports CAN nodes
(Chinese) Chinese)
Flatp Fl atpac ack2 k2 – 1U PR “ bu buil ildi ding ng blo blocks cks” ” FP2 2kW 3 7 0 m m d e e p
FP2 3kW > Both PRs are “4 across” > Smartpack can be housed in left-hand slot
Slide 28 15/11/2010
p e e d m m 1 3 4
Acronyms
Flatpack2 Flatp ack2 – Smal Smalll Integr Integrated ated Syste System m
FP2 2kW only
Acronyms
Includes (up to) :
ü 1U Distribution + 1 PR ü 8000W (166A@48V) ü Smartpack ü 2 x 100A Battery breakers ü 6 x 2–60A Load breakers Figure shown is an 8kW system with std 2kW rectifiers
ü 2 x LVD (150A) 5 kg Slide 29 15/11/2010
(excl. rectifiers)
Flatpack2 Flatp ack2 – Medi Medium um Integr Integrated ated Syste System m 2kW and 3kW options
Acronyms
Includes (up to) :
ü 2kW rectifier : rectifier : Up to 32kW ü 3kW rectifier : rectifier : Up to 24kW ü 4U Distribution + 1-4 PR ü Smartpack ü 6 x 100A (3 x 200A) BB ü 21 x 2–125A Load breakers* Figure shown is a 16kW system with std 2kW rectifiers
ü 2 x LVD (up to 600A) * Check datasheet for ot her available combinations
Up to 10 kg (excl. rectifiers) Slide 30 15/11/2010
Flatp Fl atpack ack2 2 – “IF “IFC C Large Large Powe Power” r” 2kW and 3Kw options ü
2kW rectifier : rectifier : Up to 96 kW
ü
3kW rectifier : rectifier : Up to 108 kW
ü
IFC Cabinet : 2000 x 600 x 600 mm
ü
Input 230V/400V 3-phase
ü
2 x Battery & 6 x Load Fuse options opt ions
ü
Secondary 30 x MCB dist. option
Slide 31 15/11/2010
Acronyms
Telecom Product Families Micropack Minipack Flatpack2 Ø
Powerpack Cabinets Remote Power System
Slide 32 15/11/2010
Powerpack Rectifiers
Acronyms
Main Characteristics
2U
>
True 3 Phase rectifier
>
Up to 5800W output
>
CAN Bus communication
>
“Hot-swappable”
>
“4 ac across” 23” PR
364 mm
161 mm
Models 48V 5800W 400/480 Vac
(241246.500)
* Option for “IFC Large Power ” * Derates to 3.5kW at 208VAC input Slide 33 15/11/2010
Powerpack Rectifiers 500 mm
2U
Acronyms
Main Characteristics >
True 3 Phase rectifier
>
Up to 11kW output
>
Basic controller built-in
>
Models for different AC inputs
>
CAN Bus communication
>
Not “hot-swappable”
585 mm
Models 11kW 48V 480VAC (241246.000) * * Derates to 9.6kW w with ith 400VAC input
11kW 48V 208VAC (241246.100)
Slide 34 15/11/2010
Smartpack Controller
Acronyms
Smartpack Extended (242100.110)
144 mm
Smartpack RS-232 Front (242100.111) 43 mm “1U”
Smartpack GB RS-232 Front (242100.114)
109 mm
Smartpack WEB/SNMP 6+6 (242100.118)
Main Characteristics
Slide 35 15/11/2010
>
CAN Bus communication
>
LCD screen and keypad
>
User connects via USB
>
Supports CAN nodes
(Chinese) Chinese)
Powerpack 5,8kW System Solution Main Characteristics
Slide 36 15/11/2010
>
2000 x 600 x 600 mm
>
Up to 20 Rectifiers per cabinet
>
Bulk-Feed or integrated distribution
>
Top or Bottom Entry
>
Maximum 116kW per cabinet
Powerpack 11kW System solution Main Characteristics > 2000 x 600 x 600 mm > Up to 10 Stacked Rectifiers > Bulk-Feed or integrated distribution > Top or Bottom Entry > Maximum 2300 Amps per bay
Slide 37 15/11/2010
Telecom Product Families Micropack Minipack Flatpack2 Powerpack Ø
Cabinets Remote Power System
Slide 38 15/11/2010
Integrated Frame Cabinet (IFC) Current Range H
x
Main Characteristics
W x D (mm)
700 x 600 x 400
>
Cost-effective cabinet
>
Steel construction
>
1.2 Tonn weight capacity
>
Typically “Top Entry”
>
Some sizes have “Flatpacked”
1000 x 600 x 400 1200 x 600 x 600 1500 x 600 x 600 * 1800 x 600 x 400 * 1800 x 600 x 600 * 1800 x 600 x 400 2000 x 600 x 400 2000 x 600 x 600 *
* Available in Silver finish al so
option
Slide 39 15/11/2010
(assemble locally)
Type 2 Outdoor cabinet 15U Type 2 Fan/filter
(237143)
15U Type 2 T20 AC
(250661)
Main Characteristics 888 mm
> Common body with different door type for Fan/filter or Air Conditioner > 19” mounti mounting ng only only > 15U of mounting mounting space * 527 mm 586 mm
Slide 40 15/11/2010
Lower 3U typically for AC Distribution
> Wall, Floor or Pole mount kits
Type 3 Outdoor cabinet Main Characteristics > Single skin, insulated > Select door for cooling option 1 Fan/filter 2 Fan /Filter Air Conditioner Conditioner HEX
> Height 1.5 or 1.8m > Foot print 700 (W) x 760 (D) mm + Cooling option depth Figure shown is 2 Fan/Filter option
Slide 41 15/11/2010
Telecom Product Families Micropack Minipack Flatpack2 Powerpack Cabinets Ø
Slide 42 15/11/2010
Remote Power System
RPS Block diagram “RFT-V “RFT-V” ” Type Type : Remote Feeding Telecommunicat Telecommunication ion – Voltage limited limited
Typical distance : 5 to 10 km
Also known as ‘span power’ or ‘line power’ Slide 43 15/11/2010
DC-DC Converter module
Acronyms
DC / DC Converter >
Converts -48VDC to 190VDC
>
To achieve 380VDC potential, a positive and negative output from a pair are connected to Earth
(Refer to datasheet for specifications)
Slide 44 15/11/2010
VA Limiter module
Acronyms
Output Channels >
Provides 380VDC output, limited to 100W.
>
Provides earth leakage, surge and short circuit protection.
(Refer to datasheet for specifications)
Slide 45 15/11/2010
Remote End module
Acronyms
Remote End Converter > >
Converts DC input to -48VDC. Input voltage and output power depend on the characteristics of the twist pair circuit.
(Refer to datasheet datasheet for specifications) specifications)
Slide 46 15/11/2010
Typical distance : up to 10 km
System Installation example
MDF
+/-190V
- 48V - 48V
M DF =
Slide 47 15/11/2010
Main Distribution Frame
Vision
THE GREATEST POWER IN THE INDUSTRY
Slide 48 15/11/2010