INTERNATIONAL STANDARD
ISO 14617-1
--`,,``,`-`-`,,`,,`,`,,`---
Second edition 2005-07-15
Graphical symbols for diagrams — Part 1: General information and indexes Symboles graphiques pour schémas — Partie 1: Informations générales et index
Reference number ISO 14617-1:2005(E)
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 Not for Resale
ISO 14617-1:2005(E)
PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated.
--`,,``,`-`-`,,`,,`,`,,`---
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2005 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body in the country of the requester. ISO copyright office Case postale 56 • CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail
[email protected] Web www.iso.org Published in Switzerland
ii
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Contents
Page
Foreword............................................................................................................................................................ iv Introduction ........................................................................................................................................................ v 1
Scope ......................................................................................................................................................1
2
Normative references ............................................................................................................................1
3
Terms and definitions ...........................................................................................................................1
4
Arrangement of ISO 14617....................................................................................................................2
5
Registration numbers............................................................................................................................3
6
Presentation of graphical symbols ......................................................................................................4
7
Application rules and examples...........................................................................................................5
8
Use of graphical symbols .....................................................................................................................5
9
Lettering..................................................................................................................................................5
10
Indexes....................................................................................................................................................6
Annex A (informative) Alphabetical index ........................................................................................................7 Annex B (informative) Index of graphical symbol registration numbers ....................................................34 Annex C (informative) Cross-reference index ................................................................................................41 Bibliography ......................................................................................................................................................55
--`,,``,`-`-`,,`,,`,`,,`---
iii
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 14617-1 was prepared by Technical Committee ISO/TC 10, Technical product documentation, Subcommittee SC 10, Process plant documentation and tpd-symbols. This second edition cancels and replaces the first edition (ISO 14617-1:2002), of which it constitutes a minor revision. ISO 14617 consists of the following parts, under the general title Graphical symbols for diagrams :
Part 1: General information and indexes
Part 2: Symbols having general application
Part 3: Connections and related devices
Part 4: Actuators and related devices
Part 5: Measurement and control devices
Part 6: Measurement and control functions
Part 7: Basic mechanical components
Part 8: Valves and dampers
Part 9: Pumps, compressors and fans
Part 10: Fluid power converters
Part 11: Devices for heat transfer and heat engines
Part 12: Devices for separating, purification and mixing
Part 13: Devices for material processing
Part 14: Devices for transport and handling of material
Part 15: Installation diagrams and network maps --`,,``,`-`-`,,`,,`,`,,`---
iv
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Introduction
--`,,``,`-`-`,,`,,`,`,,`---
The purpose of ISO 14617 in its final form is the creation of a library of harmonized graphical symbols for diagrams used in technical applications. This work has been, and will be, performed in close cooperation between ISO and IEC. The ultimate result is intended to be published as a standard common to ISO and IEC, which their technical committees responsible for specific application fields can use in preparing International Standards and manuals.
v
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
--`,,``,`-`-`,,`,,`,`,,`---
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
INTERNATIONAL STANDARD
ISO 14617-1:2005(E)
Graphical symbols for diagrams — Part 1: General information and indexes
1
Scope
This part of ISO 14617 serves as an introduction to all the other parts. In particular, it gives information on the creation and use of registration numbers for identifying graphical symbols used in diagrams, rules for the presentation and application of these symbols, and examples of their use and application. It includes three indexes: an alphabetical index and an index of registration numbers — both concerned uniquely with ISO 14617 — and an index of cross-references to related items found in other International Standards. For the fundamental rules of creation and application of graphical symbols in diagrams, see ISO 81714-1.
--`,,``,`-`-`,,`,,`,`,,`---
2
Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 81714-1:1999, Design of graphical symbols for use in the technical documentation of products — Part 1: Basic rules
3
Terms and definitions
For the purposes of this document, the following terms and definitions apply. NOTE The list has been restricted to terms whose meaning is not obvious and which have not been defined elsewhere in an International Standard, or which have been defined in various ways in different standards. In preparing these definitions, ISO and IEC standards on terminology have been consulted; see the references in parentheses. However, most of the definitions in those standards were prepared by different technical committees within a restricted scope. This means that many terms so defined have to be given more general or neutral definitions when applied in the context of graphical symbols.
3.1 function activity proper to anything, mode of action by which it fulfils its purpose EXAMPLE
To measure, to control, to indicate.
3.2 product thing produced by natural process or manufacture; result EXAMPLE
An element, a component or a device.
1
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
3.3 component constituent part of equipment that cannot be physically divided into smaller parts without losing its character [IEC 60050-131] 3.4 device assembly of components to perform a required function EXAMPLE
An actuating device, a centrifuge.
[IEC 60050-151] 3.5 element part of a component EXAMPLE
A filter element in a filter, a contact in an electromechanical relay.
--`,,``,`-`-`,,`,,`,`,,`---
3.6 graphical symbol visually perceptible figure used to transmit information independently of language [ISO 81714-1] 3.7 terminal line line of a graphical symbol ending at a connect node NOTE
A connect node is a location on a graphical symbol intended for connection (ISO 81714-1).
[ISO 81714-1] 3.8 connecting line graphical symbol representing a functional connection, a mechanical link, a pipeline, a duct, or an electric connection [IEC 61082-1]
4 4.1
Arrangement of ISO 14617 Domains of application
The complete ISO 14617 is to consist of a number of other parts in addition to those listed in the Foreword. Among the parts under preparation are ISO 14617-13, concerned with graphical symbols for material processing, and ISO 14617-14, concerned with the symbols representing devices for transport and handling of material. This part of ISO 14617 is an introduction to all the other parts. ISO 14617-2 to ISO 14617-6 cover graphical symbols for use in most technical fields. ISO 14617-7 to ISO 14617-12 cover those for use in all fields except the electrotechnical. ISO 14617-15 comprises graphical symbols for use in installation diagrams and on network maps for pipelines, ducts and electric connections.
2
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E) --`,,``,`-`-`,,`,,`,`,,`---
4.2
Subdivision of parts
Each part of ISO 14617 is divided into clauses that each deal with graphical symbols for a particular group of generic products or functions. When appropriate, clauses are given subclauses, as follows using the example of Clause 7 from ISO 14617-2: Clause 7
Directions
Subclause 7.1
Symbols of basic nature
Subclause 7.2
Application rules for the symbols in 7.1
Subclause 7.3
Symbols giving supplementary information
Subclause 7.4
Application rules for the symbols in 7.3
Subclause 7.5
Application examples
Where certain subclauses are further subdivided, this has been done along the following lines. Take, for example, 4.3 in ISO 14617-2: Subclause 4.3
Symbols giving supplementary information
Subclause 4.3.1
Input and output labels
Subclause 4.3.2
General functions
Subclause 4.3.3
Mathematical operations
Subclause 4.3.4
Change of discrete state at specified values of a characteristic quantity
Subclause 4.3.5
Logic negation, logic inversion, inputs and outputs for auxiliary power supply
When a cross-reference is made to a particular graphical symbol or application rule or application example, its location is given within parentheses after the registration number of the symbol, rule or example. EXAMPLE 1
“See R101 (4.2.1)” directs the reader to application rule R101, located in subclause 4.2.1.
When cross-referencing to another part, the part number is also included. EXAMPLE 2
5
A cross-reference to symbol 142 in ISO 14617-2 is given as “See 142 (2-4.3.2.28)”.
Registration numbers
IMPORTANT — A direct relationship does not necessarily exist between graphical symbols, application rules and application examples using registration numbers that share the same numerals. For example, while graphical symbol 101 correlates to both application rule R101 and application example X101, it correlates as well to application examples X102 to X114; whereas symbol 114, to take just one other example, is unrelated to R114 and X114.
5.1
Graphical symbol
Each graphical symbol is assigned a unique registration number. In principle, this number is arbitrarily chosen. No information can be derived from it. The registration number will remain unchanged throughout the lifetime of the corresponding graphical symbol, including in future revisions of this publication. If a graphical symbol is changed in the future, the registration number shall be supplemented with one or more characters. If the graphical symbol is substantially changed, it shall instead be given a new registration number.
3
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
5.2
Application rule
Each application rule has a registration number in the same way as the graphical symbols, except that the registration number starts with the letter R (e.g. R101).
5.3
Application example
Each application example has a registration number in the same way as the graphical symbols, except that the registration number starts with the letter X (e.g. X101).
6 6.1
Presentation of graphical symbols General
ISO 14617 establishes graphical symbols to be used in diagrams such as overview diagrams, flow diagrams and circuit diagrams.
6.2
Graphical symbols of same shape but different meaning
Graphical symbols having the same shape but different meanings have different registration numbers. This implies that it is possible to distinguish between same-shape graphical symbols in a CAD (computer-aided design) system, provided that each symbol has been recalled from a CAD library using the appropriate registration number. For a person reading a diagram, the intended meaning can normally be recognized by the context of the diagram. When this is not possible, graphical symbols having the same shape shall be provided with supplementary information. For examples, see the symbols for connections in ISO 14617-3 and the rules for adding symbols giving supplementary information such as application rule R402 in the same part.
6.3
Different forms of graphical symbols
In some cases, different forms of a graphical symbol can occur. These different forms are given separate registration numbers. The primary reason for having two or more forms for the same symbolization is that they convey differing amounts of information. Symbols having different forms and differing amounts of information (e.g. those for use in overview diagrams and those for use in circuit diagrams) are marked Form 1, Form 2, etc. This marking is also used in some cases where the different forms contain the same amount of information, but where more than one form is justified because of different application methods in the rules for preparing diagrams.
Dimensions of graphical symbols
The graphical symbols in ISO 14617 have been designed in accordance with the rules given in ISO 81714-1. The module size M = 2,5 mm has been used. For small graphical symbols, the symbol is shown double its normal size, applying the same module and the same line width. Such symbols are marked “200 %”. For the auxiliary grid system defined in ISO 81714-1, the module 0,25 M has been used.
6.5
Descriptions
In those cases where ISO and IEC have the same term for different items, the term has been provided with ISO and IEC superscripts, for example, line ISO and line IEC.
4
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
--`,,``,`-`-`,,`,,`,`,,`---
6.4
ISO 14617-1:2005(E)
7
Application rules and examples
The application rules give information on how to design composite symbols and how to apply the graphical symbols in a diagram. The application examples are to be regarded as guidelines. In order to facilitate their use, the application examples are accompanied by information on which graphical symbols have been used to compose the examples shown. EXAMPLE
8 8.1
“101, 123” in 2-4.5.8 signifies that the example X108 is built up from graphical symbols 101 and 123.
Use of graphical symbols Choice of graphical symbols
Rules for the choice of graphical symbols are given in the standards for the preparation of diagrams.
8.2
Dimensions of graphical symbols
Symbols may be increased in size, for example, in order to allow all terminals to be represented. They may also be reduced in size. In both cases, the original line width shall be maintained.
8.3
--`,,``,`-`-`,,`,,`,`,,`---
Further rules for the use of graphical symbol sizes and line widths are given in the standards dealing with the preparation of diagrams.
Auxiliary lines
In some cases, the symbol has been shown together with auxiliary lines in order to indicate its correct location in relation to other symbols or the recommended location of connecting lines. Such auxiliary lines are not part of the symbol and are shown dotted (very short dashes). EXAMPLE 1
Symbol 181 — logic negation — shown at an outline of a symbol indicated by a dotted rectangle.
EXAMPLE 2 symbol 2101.
An auxiliary line indicating the correct location of the symbol for a connection to a two-way valve,
8.4
Variants of graphical symbols
The rules for diagram layout give the possibility of arranging circuits horizontally or vertically, and of arranging circuits for feedback and similar signals in a direction opposite to the normal one. For that purpose, different variants of the graphical symbols exist. The rules for the creation of the different variants are given in ISO 81714-1.
9
Lettering
For lettering, see ISO 81714-1.
5
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E) --`,,``,`-`-`,,`,,`,`,,`---
10 Indexes The alphabetic index given in Annex A can be used to find a graphical symbol for a certain component, device or function wherever the meaning (description) is known. This index also covers the application examples. The registration number index given in Annex B can be used to locate a graphical symbol whose registration number is already known. The cross-reference index given in Annex C is intended as a link between the registration numbers and the corresponding descriptions in other, existing ISO and IEC standards.
6
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Annex A (informative) Alphabetical index
This alphabetical index can be used to find a graphical symbol for a certain component, device, or function if its meaning (description) is already known. The index also covers the application examples.
Description
RegisLocation tration (Partnumber subclause)
Above ground hydrant .................................... 3122 Access chamber – Circular-shaped ~, inspection well ............. 3087 Acoustic signalling device ............................... 866 Active area – Double-acting hydraulic actuator with different ∼s.......................................... 721 – Double-acting pneumatic actuator with different ~s.......................................... 722 Actuating device.............................................. 741 – of double-acting diaphragm actuator type ............................................................ X743 – of electric motor type ................................. X2131 – of pneumatic motor type ............................ X742 – of single-acting fluid cylinder type .............. X741 – operated by pneumatic power stored inside actuator ........................................... X747 – operating with touch effect......................... X744 – Spring-operated ~ with manual spring charging ..................................................... X745 – Spring-operated ~ with spring charging by electric motor ........................................ X746 – Spring-loaded ~ ......................................... X2005 Actuating devices............................................ – Actuator – Cam-operated ~......................................... 714 – Device for restricted access to ~................ 692 – Double-acting diaphragm ~ ....................... 726 – Double-acting ~ of fluid cylinder type......... X2107 – Double-acting hydraulic ~ .......................... 719 – Double-acting, hydraulic ~ with different active areas ................................. 721 – Double-acting, pneumatic ~....................... 720 – Double-acting pneumatic ~ with different active areas ................................. 722 – Flow-target-operated ~ .............................. 716 – Fluid-level-operated ~................................ 715 – in the form of a double-acting fluid cylinder ...................................................... 724 X713 X2107 – in the form of a hydraulic motor with alternative directions of flow ...................... 2407 – in the form of a pneumatic motor .............. X712 – in the form of a pneumatic motor with alternative directions of flow ...................... 2408 – in the form of a single-acting fluid cylinder ...................................................... 723 – Manual ~.................................................... 681 – Manual ~ in the form of key ....................... 687 – Manual ~ in the form of lever ..................... 688 – Manual ~ in the form of pedal .................... 689
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
15-7.2 15-5.1.7 5-10.1.4 4-6.1.11 4-6.1.12 4-7.1.1 4-7.5.3 8-4.5.4.1 4-7.5.2 4-7.5.1 4-7.5.7 4-7.5.4 4-7.5.5 4-7.5.6 7-4.5.5 4-7
Description
RegisLocation tration (Partnumber subclause)
– Manual ~ in the form of removable handle.........................................................686 – Manual ~ in the form of treadle...................690 – Manual ~ operated by pulling .....................683 – Manual ~ operated by pushing ...................682 – Manual ~ operated by pushing and pulling .........................................................684 – Manual ~ operated by turning.....................685 – Manual ~ with special shape for safety purpose.......................................................691 – operating when actual temperature is less than set value ..................................X717 – Single-acting diaphragm ~..........................725 X2136 X2138 X2152 – Single-acting hydraulic ~ ............................717 – Single-acting pneumatic ~ ..........................718 Actuators – Automatic ~.................................................– See also Hydraulic actuators, Pneumatic actuators, Manually operated actuators Additional simplifications..................................– Adjustability......................................................201
4-6.1.4 4-5.1.12 4-6.1.16 8-4.5.1.7 4-6.1.9 – Non-linear ~ ................................................202 – Pre-set ~ .....................................................203
4-6.1.11 4-6.1.10 4-6.1.12 4-6.1.6 7-4.1.5 4-6.1.5 7-4.1.4 4-6.1.14 4-6.5.3 8-4.5.1.7 4-6.1.17 4-6.5.2 4-6.1.18 4-6.1.13 4-5.1.1 4-5.1.7 4-5.1.8 4-5.1.9
– Resistor with continuous ~..........................X203 – Resistor with electric-motor-operated ~......X205 – Resistor with manual ~ ...............................X204 – Resistor with pre-set ~................................X201 – Resistor with ~ in five steps ........................X202 See also Variability Adjustable capacity – Hydraulic pump with ~ ................................X2401 X2402 – Liquid pump with ~......................................X2301 X2302 – Over-centre hydraulic pump with ~.............X2407 Adjustable gain – Amplifier with ~ ...........................................X207 Adjustable hydraulic rotary torque converter.....................................................X2431 Adjustable restrictor (valve) .............................X2211 X2212
4-5.1.6 4-5.1.10 4-5.1.3 4-5.1.2 4-5.1.4 4-5.1.5 4-5.1.11 4-6.5.5 4-6.1.15 8-4.5.4.6 8-4.5.4.8 8-5.5.2 4-6.1.7 4-6.1.8 4-6 3-9 2-5.1.1 8-4.3.1.3 8-5.3.3 9-4.3.1 10-4.3.1 10-5.3.1 14-4.3.1 2-5.1.2 2-5.1.3 8-4.3.1.4 8-5.3.4 10-4.3.2 2-5.5.3 2-5.5.5 2-5.5.4 2-5.5.1 2-5.5.2 10-4.5.1 10-4.5.2 9-4.5.1 9-4.5.2 10-4.5.7 2-5.5.7 10-5.5.1 8-6.5.3.1 8-6.5.3.2
7
--`,,``,`-`-`,,`,,`,`,,`---
Not for Resale
ISO 14617-1:2005(E)
RegisLocation tration (Partnumber subclause)
– with adjustable flow in one direction and restricted flow in the other ..................X2213 Adjustable speed – Hydraulic motor with ~................................X2415 – Hydraulic pump driven by shaft with ~........X2404 – Liquid pump driven by shaft with ~ .............X2303 Adsorption pump..............................................2335 2336 Affected area ...................................................2177 Agglomeration – Size enlarging by sintering,~ coagulation, or flocculation .........................2809 Air conditioner..................................................X3152 – for pneumatic systems................................2691 Air conditioning ................................................3151 Air fin cooler with induced draft........................X2505 Air lubricator.....................................................X2674 Alarm ...............................................................3066 – High pressure ~ ..........................................X1062 – Indicating and transmitting of level, registering, and ~........................................X1065 – Light ~.........................................................3067 Air conditioner for pneumatic systems.............2691 Air fin cooler with induced draft........................X2505 Air lubricator.....................................................X2674 Alarm – High pressure ~ ..........................................X1062 – Indicating and transmitting of level, registering, and ~........................................X1065 Alarming...........................................................1051 All-or-nothing relay – Electromechanical ~ with some contacts delayed.........................................X653 – Electromechanical ~, the whole relay delayed when coil is energized...................X654 Alternative directions – Direction of propagation, energy, or signal flow, ~ (half-duplex)..........................250 – Gas pump, compressor, fan with ~ of flow .............................................................2304 – Hydraulic pump/motor with ~ of flow .........2413 – Hydraulic motor with ~ of flow ....................2407 – Hydraulic pump with ~ of flow.....................2403 – in general, except for energy and signal flow...................................................245 246 Limited circular motion in ~.........................X253 Liquid pump with ~ of flow ..........................2303 of circular motion ........................................256 of propagation, energy, or signal flow (half-duplex)................................................250 – Pneumatic motor with ~ of flow ..................2408 – Pneumatic pump, compressor with ~ of flow .........................................................2404 – Pneumatic pump/motor with ~ of flow ........2414 – Rectilinear motion in ~ with intermediate dwell.......................................X256 Amplification ....................................................115 – – – –
Amplifier...........................................................891 892 – Differential ~ ...............................................X910 – Summing ~ .................................................X909 – with adjustable gain ....................................X207 – with return channel .....................................893 894
8-6.5.3.3 10-4.5.15 10-4.5.4 9-4.5.3 9-5.1.5 9-5.1.6 8-6.3.7 13-4.3.9 15-9.5.2 12-7.1.1 15-9.3.2 11-4.5.5 12-6.5.4 15-4.3.16 6-7.5.22 6-7.5.25 15-4.3.17 12-7.1.1 11-4.5.5 12-6.5.4 6-7.5.22 6-7.5.25 6-7.3.1.1
Description
– with the gain compensated for frequency variations ..................................X110 Amplifying equipment – Enclosure with ~ .........................................X3081 Analogue signal ...............................................234 Analogue signal processing – Devices for ~ ..............................................– Anchor point.....................................................3004 AND-elements – Component consisting of two identical ~ ...................................................X346 X347 AND-function (Logic ~) ....................................142 Angle – Measuring transducer for ~ ........................X769 Angled globe type spring-loaded vacuum valve operating when pressure is lower than set value ..................................X2125 Angled two-way valve......................................2102 Annealing – Heat treatment, for example, ~ or tempering ...................................................2807 Anti-clockwise rotation .....................................X250 X251 X2416 X2417 X2419 X2422 X2423 Anti-siphon trap................................................2038
4-4.5.3 4-4.5.4 2-7.1.8 6-4.3.3 9-4.1.4 10-4.1.13 10-4.1.7 10-4.1.3 2-7.1.5 14-4.3.3 2-7.1.6 2-7.5.8 9-4.1.3 2-7.1.14 2-7.1.8 10-4.1.8 10-4.1.4 10-4.1.14 2-7.5.11 2-4.3.2.5 6-7.3.3.1 5-12.1.1 5-12.1.2 5-12.5.10 5-12.5.9 2-5.5.7 5-12.1.3 5-12.1.4
Approximately constant force, motion, or flow .............................................................223 Area – Affected ~ ...................................................2177 Areas – Double-acting hydraulic actuator with different active ~..................................721 – Double-acting pneumatic actuator with different active ~..................................722 Arrestor – Flame ~ ......................................................2036 Automatic actuators.........................................– Automatic closing – Quick-release coupling element of female type with ~ .....................................567 – Quick-release coupling element of male type with ~ ........................................566 – Quick-release coupling element which fits into another coupling element of the same type with ~ ................568 Automatic operation.........................................144 – of final controlling element..........................1022 – of pump ......................................................X1031 – of valve controlled by analogue signal .......X1028 X1035 – of valve with infinite number of stable positions .....................................................X1034 X1036 – of valve with automatic return to closed position............................................X1026 – of valve with automatic return to open position ..............................................X1027 – of valve with automatic return towards closed position ..............................X1029 – of valve with automatic return towards open position ................................X1030
8
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause) 2-4.5.10 15-5.5.1 2-6.1.14 6-4.3.5 5-12 15-4.1.4 2-11.5.3 2-11.5.4 2-4.3.2.28 6-7.3.3.12 5-4.5.19 8-4.5.3.5 8-4.1.2 13-4.3.7 2-7.5.5 2-7.5.6 10-4.5.16 10-4.5.17 10-4.5.19 10-4.5.22 10-4.5.23 7-5.1.12 15-10.3.5 2-6.1.3 8-6.3.7 4-6.1.11 4-6.1.12 7-5.1.10 4-6 3-8.1.6 3-8.1.5 3-8.1.7 2-4.3.2.30 6-6.1.2 6-6.5.11 6-6.5.8 6-6.5.15 6-6.5.14 6-6.5.16 6-6.5.6 6-6.5.7 6-6.5.9 6-6.5.10
© ISO 2005 – All rights reserved Not for Resale
--`,,``,`-`-`,,`,,`,`,,`---
Description
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
– of valve with two stable positions, open and closed ........................................ X1032 X1033 Automatic return – Control-switch operated by turning with ~ from two extreme positions ............. X686 – device ........................................................ 654 – Directional control valve with ~ .................. X688 – Single-acting hydraulic cylinder with ~....... X2442 – Manually operated control-switch with ~ ......................................................... X685 – Manually operated valve with ~ ................. X1022 – Valve with diaphragm actuator and ~ ........ X2101 Auxiliary location – in central control room ............................... 1102 – in local control room or on local control panel .............................................. 1104 Auxiliary power supply – Input or output for ~ ................................... 183 Averaging – Device for ~ ............................................... X903 – function component ................................... X105
--`,,``,`-`-`,,`,,`,`,,`---
Back-pressure control valve, selfoperating.................................................... X2132 Back-up – function ...................................................... – – Temperature indication and control performed by computer with ~ by discrete device........................................... X1081 Bag.................................................................. 2068 Bag filter.......................................................... X2606 Ball .................................................................. 2014 2015 Ball type .......................................................... 2122 – control valve, operated by diaphragm actuator or by manual actuator.................. X2138 – Spring-loaded ~ non-return valve .............. X2115 – three-way valve with double-acting cylinder actuator ........................................ X2107 Barrel .............................................................. 2067 Basic elements (for actuators and actuating devices)...................................... – Bath scrubber.................................................. X2622 Beam – Non-guided, electromagnetic ~.................. 411 Bearing............................................................ 2006 Bed filter – of fixed type ............................................... X2609 – of fluidized type.......................................... X2610 Bed filter element – of fixed type ............................................... 2603 – of fluidized type.......................................... 2604 Bellows – Expansion ~............................................... 533 Belt conveyor – Mobile ~ with scraper flights and adjustable elevation ................................... X3804 – Uni-directional driven ~ by electric motor.......................................................... X3801 – with adjustable length ................................ X3806 Belt filter .......................................................... X2608 Belt type .......................................................... 3821 – with scraper flights ..................................... 3822 Bending – Material forming by ~ or folding ................. 2804 Belt filter .......................................................... X2608
Description
Bias..................................................................162 6-6.5.12 6-6.5.13
– Device for ~ ................................................X904 – function component ....................................X103 Bidirectional information bus type ....................443 Bidirectional, simultaneously............................247 Bimetal.............................................................327 Binary logic elements.......................................– Binary logic functions .......................................– Binary signal ....................................................236
4-5.5.6 4-4.1.9 6-6.3.4 4-5.5.8 10-6.5.2 4-5.5.5 6-6.5.2 8-4.5.1.1 6-7.3.4.2 6-7.3.4.4 2-4.3.5.3 5-12.5.3 2-4.5.5 8-4.5.4.2 6-9 6-9.5.1 7-6.1.8 12-4.5.6 7-4.1.20 7-4.1.21 8-4.3.2.2 8-4.5.4.8 8-4.5.2.5 8-4.5.1.7 7-6.1.7 4-4 12-4.5.22 3-4.1.7 7-4.1.12 12-4.5.9 12-4.5.10 12-4.1.4 12-4.1.5 3-7.1.3 14-4.5.4 14-4.5.1 14-4.5.6 12-4.5.8 14-4.3.6 14-4.3.7 13-4.3.4 12-4.5.8
Biologic filter.....................................................X2634 Biologic type.....................................................2623 Bistable element – RS-~ ...........................................................X112 Bleed line .........................................................422 Blind .................................................................2043 – flange pair...................................................517 – Spectacle ~ in closed position ....................2044 – Spectacle ~ in open position.......................2045 Blocking device................................................664 Blocking of electric current...............................3063 – Device for ~ in a pipeline ............................X3011 Boiler................................................................2531 – feed-water vessel with deaerator................X2071 – of electrode type .........................................X2533 – of fired type .................................................X2531 – with dome ...................................................2532 – with superheater .........................................X2534 Boilers ..............................................................– Bore – Reduced ~ ..................................................2130 Boring, drilling ..................................................2815 Boss with – insertion pipe ..............................................803 – Temperature sensor in a ~ well ..................X801 – well .............................................................801 Brake – applied in unactuated state.........................2012 – disengaged in unactuated state..................2011 – Solenoid-operated ~ applied at no-voltage...................................................X652 Branches – Connection with n parallel identical ~ .........601 – Eight connections, four of them branching....................................................X602 – Three parallel identical ~ ............................X601 Branching of a bundle ......................................X607 X608 Brazed joint ......................................................515 Breaking – Size reduction by crushing, ~, or pulverisation ...............................................2808 Buffer head ......................................................2007 Buffer – Hydraulic ~..................................................X2007 – Spring equipped ~ ......................................X2006 Bulldozer ..........................................................3867 Burglar detector ...............................................X3141 Buffer head ......................................................2007 Bundle – Branching of a ~ .........................................X607 X608 – Exit from or entrance into a ~ .....................603 Bunker..............................................................2064 – Open ~........................................................X2074
2-4.3.3.2 6-7.3.3.16 5-12.5.4 2-4.5.3 3-4.3.7 14-4.3.4 2-10.1.5 5-11 6-8 2-6.1.16 6-4.3.7 12-4.5.34 12-4.3.11 2-4.5.12 3-4.1.10 7-5.1.17 3-6.1.7 7-5.1.18 7-5.1.19 4-4.1.20 6-6.3.9 15-4.3.13 15-4.5.11 11-7.1.1 7-6.5.11 11-7.5.3 11-7.5.1 11-7.1.2 11-7.5.4 11-7 8-4.3.2.10 13-4.3.15 5-5.1.3 5-5.5.1 5-5.1.1 4-4.1.5 7-4.1.18 4-4.1.4 7-4.1.17 4-4.5.2 3-9.1.1 3-9.5.2 3-9.5.1 3-9.5.7 3-9.5.8 3-6.1.5 13-4.3.8 7-4.1.13 7-4.5.7 7-4.5.6 14-7.1.7 15-8.5.11 7-4.1.13 3-9.5.7 3-9.5.8 3-9.1.3 7-6.1.4 7-6.5.14
9
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause)
Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
Burst of sinusoidal flow ....................................226 Bus – Bidirectional information ~ type ..................443 – Unidirectional information ~ type ................442 Butterfly type....................................................2126 Cable (pipe unit) ..............................................449 – Four pipelines forming a unit ......................X421 – Four pipelines, two of them forming a ~ .....X422 Calendering .....................................................2826 Cam driven mechanical counter with output closing at each n events ..................X877 Cam profile ......................................................713 – and roller.....................................................X711 Cam-operated actuator....................................714 Candle filter......................................................X2606 Cap – End ~ ..........................................................518 Capacitive type ................................................IEC Capillary type ...................................................432 Cargo ship .......................................................3881 Cargo ships......................................................– Cartridge filter ..................................................X2606 Cascade control – Temperature-flow rate ~ .............................X1105 Casting or moulding.........................................2801 Casting machine ..............................................X2801 Casting machines and machine tools..............– Catalytic type ...................................................2661 – Purifier of ~ .................................................X2651 Central control room – Auxiliary location in a ~...............................1102 – Primary location in a ~................................1101 – Temperature indication in a ~.....................X1075 – Temperature indication in a ~, instrument not accessible to operator.........X1076 Centrifugal filter................................................X2614 Centrifuge – Decanter ~..................................................X2620 – High-speed ~ ..............................................X2619 – rotor ............................................................2608 Chain or wire driven type .................................3823 Change – of pipe dimension; pipe reducer .................516 Change of state when the characteristic quantity – is approximately equal to the set value ......175 – is equal to the set value..............................174 – passes the set value from above................172 – passes the set value from below ................171 – passes the upper set value from below or the lower set value from above ..............173 Characteristic quantity – Actuator operating when the ~ passes the set value...................................733 – Change of state when the ~ is approximately equal to the set value ..........175 – Change of state when the ~ is equal to the set value ...........................................174 – Change of state when the ~ passes the set value from above ...............172 – Change of state when the ~ passes the set value from below.............................171
2-6.1.6 3-4.3.7 3-4.3.6 8-4.3.2.6 3-4.3.14 3-4.5.14 3-4.5.15 13-4.3.26 5-8.5.7 4-6.1.3 7-4.1.3 4-6.5.1 4-6.1.4 12-4.5.6 3-6.1.8 5-4.3.1.13 3-4.3.2 14-7.1.16 14-7 12-4.5.6 6-10.5 13-4.3.1 13-4.5.1 13-4 12-5.3.1 12-5.5.1 6-7.3.4.2 6-7.3.4.1 6-7.5.35 6-7.5.36 12-4.5.14 12-4.5.20 12-4.5.19 12-4.1.9 14-4.3.8 3-6.1.6 2-4.3.4.5 2-4.3.4.4 2-4.3.4.2 8-4.3.1.6 2-4.3.4.1 8-4.3.1.5 2-4.3.4.3 4-6.1.19 2-4.3.4.5 2-4.3.4.4 2-4.3.4.2 8-4.3.1.6 2-4.3.4.1 8-4.3.1.5
Description
RegisLocation tration (Partnumber subclause)
– Change of state when the ~ passes the upper set value from below or the lower set value from above ..................173 Characteristics for force, motion, mass flow, magnetic flow, and signals.................– Check function: See Non-return function Check valve: See Non-return valve Chemical type..................................................2622 Circular motion – Direction of ~ ..............................................255 – limited in alternative directions ...................X253 – with alternative directions ...........................256 – with unspecified direction ...........................254 Circular shape..................................................445 Circular-shaped access chamber, inspection well ............................................3087 Cistern for atmospheric pressure.....................2061 Cistern for atmospheric pressure.....................2061 Clock................................................................842 – Master ~ .....................................................843 Clocks..............................................................– Clock-wise rotation ..........................................X249 X250 X251 X2304 X2305 X2306 X2405 X2406 X2407 Closed end of pipeline or duct .........................503 Closed flow path ..............................................2172 Closed flow path of a leak-free valve...............2173 Closed tank for atmospheric pressure.............X2061 Clutch – disengaged in unactuated state .................2009 – engaged in unactuated state ......................2010 – Solenoid-operated ~, disengaged at no-voltage...................................................X651 Coagulation – Size enlarging by sintering, agglomeration, ~, or flocculation ................2809 Coating, for example, painting .........................2827 Coil – Heating or cooling ~ ...................................2501 Column – Tray ~, fractionating ~.................................X2625 X5626 Combined non-return valve and manually actuated stop valve ....................................X2112 Combustion engine – External ~ ...................................................2583 – Internal ~ ....................................................2582 – Internal ~ with reciprocating pistons ...........X2581 – Internal ~ with rotating pistons....................X2582 Comparing .......................................................140 Compensated – Amplifier with gain ~ for frequency variations ....................................................X110 – output .........................................................128 – Pressure and temperature ~ flow control valve ...............................................X2216 X2217
2-4.3.4.3 2-6 12-4.3.10 2-7.1.13 12-4.3.2 2-7.5.8 2-7.1.14 2-7.1.12 12-4.3.1 3-4.3.10 15-5.1.7 15-10.3.6 7-6.1.1 5-8.1.2 5-8.1.3 5-8 2-7.5.4 2-7.5.5 2-7.5.6 9-4.5.4 9-4.5.5 9-4.5.6 10-4.5.5 10-4.5.6 10-4.5.7 3-5.1.3 8-6.3.2 8-6.3.3 7-6.5.1 4-4.1.2 7-4.1.15 4-4.1.3 7-4.1.16 4-4.5.1 13-4.3.9 13-4.3.27 11-4.1.3 12-4,5,25 12-4.5.26 8-4.5.2.2 11-10.1.3 11-10.1.2 11-10.5.1 11-10.5.2 2-4.3.2.26 6-7.3.3.11 2-4.5.10 2-4.3.2.14 8-6.5.3.6 8-6.5.3.7
--`,,``,`-`-`,,`,,`,`,,`---
10
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
– Pressure ~ flow control valve..................... X2214 ................................................................... X2215 – Pressure ~ flow control valve with overflow to reservoir .................................. X2218 X2219 – Pressure ~ flow divider .............................. X2220 Compensating input ........................................ 127 Complex – device ........................................................ 101 – function ...................................................... 145 145 Component consisting of – one AND-element and three OR-elements X348 – two identical AND-elements....................... X346 X347 Component selecting the highest input signal as output signal ...................... X106 Compressing screw conveyor......................... X3811 Components (in general) ................................ – Compression filter, compression by piston, screw, plate or membrane.............. X2612 Compressor .................................................... 2302 2402 – with alternative directions of flow ............... 2304 Compressors................................................... – Compressors for fluid power ........................... – Computer – Function performed by a ~ with back-up ... X1081 Computing....................................................... 1075 – Flow rate ~................................................. X1072 X1073 – Level ~ ....................................................... X1074 Condenser ...................................................... X2501 Condensers..................................................... – Conductive electrode type .............................. IEC Connection – Functional ~ ............................................... 401 – Internal ~.................................................... 451 – Internal ~ in pressure relief valve............... X435 – joints .......................................................... – – joints of specified design............................ – – of test point ................................................ 1066 – with n parallel, identical branches .............. 601 Connection boxes, access chambers, inspection wells, distribution centres ....................................................... – Connections .................................................... – – between three components (bundle) ......... X606 – Crossing of symbols for ~ .......................... X401 – Eight ~, four of them branching (single-line representation) ........................ X602 – Joint of ~ .................................................... 501 – Three ~ (single-line representation)........... X341 X342 – Three ~ with changed sequence (single-line representation) ........................ X605 – Three ~ with reversed sequence (single-line representation) ........................ X604 – Three ~ with the same sequence between two components (singleline representation) .................................... X603 – Fixed portion of ~....................................... 576 – Movable portion of ~ .................................. 577 Connectors...................................................... – Constant force, motion, or flow ....................... 221
Description
RegisLocation tration (Partnumber subclause)
8-6.5.3.4 8-6.5.3.5
Constant force, motion, or flow ........................222
8-6.5.3.8 8-6.5.3.9 8-6.5.3.10 2-4.3.2.13
Contactor – Electropneumatically operated ~ ................X405 Container for atmospheric pressure ................2061 Continuous pneumatic-hydraulic – converter.....................................................2435 – intensifier ....................................................2436 Continuous variability.......................................212 Control – Cascade ~ .................................................X1105 – Flow rate feedback ~ ..................................X1104 X1108 – Flow rate feedback ~, based on square root value of flow rate .....................X1106 – Flow rate feedback ~ with automatic closing of valve at flow rate higher than set value .............................................X1107 – Indication and feedback ~ of electric reactive power ............................................X1061 – Manual, remote ~ of a control valve with indication of the set value....................X1103 – Manual, remote ~ of valve with infinite number of stable positions and indication of valve position..........................X1102 – Manual, remote ~ of a valve with automatic return to closed position.............X1101 – Temperature-flow rate cascade ~...............X1105 – with back-up ...............................................– Control damper with double-acting fluid cylinder .......................................................X2153 Control line (fluid power systems)....................422 Control panel – Auxiliary location in a local control room or on a local ~....................................1104 – Primary location in a local control room or on a local ~....................................1103 Control room – Auxiliary location in a central ~ ...................1102 – Auxiliary location in a local ~ or on a local control panel.......................................1104 – Primary location in a central ~ ....................1101 – Primary location in a local ~ or on a local control panel.......................................1103 Control valve – Ball type ~, operated by diaphragm actuator or by manual actuator...................X2138 – Diaphragm-operated de-superheater control valve................................................X2136 – Direct hydraulically operated directional ~..X2164 X2165 – Directional leak-free ~ with two ports and two positions........................................X2183 – Directional servo-~ valve with positive overlapping in mid-position.........................X2175 – Directional servo-~ with negative overlapping in mid-position.........................X2176 – Directional ~ with four ports and three distinct positions, automatic return to mid-position ................................................X2003 – Directional ~ with four positions, operated by a lever and with one stable position and automatic return from the other positions ..............................X688 – Directional ~ with pilot valve .......................X2171 X2172 X2173 X2174
2-4.1.1 2-4.3.2.31 6-7.3.3.14 2-11.5.5 2-11.5.3 2-11.5.4 2-4.5.6 14-4.5.11 2-4 12-4.5.12 9-4.1.2 10-4.1.2 9-4.1.4 9-4 10-4 6-9.5.1 6-7.3.1.25 6-7.5.32 6-7.5.33 6-7.5.34 11-4.5.1 11-4 5-4.3.1.14 3-4.1.1 6-4.1.1 3-4.3.16 3-4.5.18 3-5 3-6 6-7.3.1.16 3-9.1.1 15-5 3-4 3-9.5.6 3-4.5.1 3-9.5.2 3-5.1.1 6-4.1.2 2-11.5.1 2-11.5.2 3-9.5.5 3-9.5.4 3-9.5.3 3-8.1.8 3-8.1.9 3-8 2-6.1.1 9-4.3.2 10-4.3.3
2-6.1.2 9-4.3.3 10-4.3.4 3-4.5.5 7-6.1.1 10-5.1.2 10-5.1.4 2-5.3.2 6-10.5 6-10.4 6-10.8 6-10.6 6-10.7 6-7.5.21 6-10.3 6-10.2 6-10.1 6-10.5 6-9 8-5.5.3 3-4.1.10 6-7.3.4.4 6-7.3.4.3 6-7.3.4.2 6-7.3.4.4 6-7.3.4.1 6-7.3.4.3 8-4.5.4.8 8-4.5.4.6 8-6.5.1.4 8-6.5.1.5 8-6.5.1.23 8-6.5.1.15 8-6.5.1.16 7-4.5.3
4-5.5.8 8-6.5.1.11 8-6.5.1.12 8-6.5.1.13 8-6.5.1.14
--`,,``,`-`-`,,`,,`,`,,`---
11
© ISOfor2005 – All rights reserved Copyright International Organization Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
– Directional ~ with three ports and three positions ............................................X2181 X2182 – Directional ~ with three ports and two positions...............................................X2179 X2180 – Electrically operated directional ~...............X2177 X2178 – Electrohydraulically or manually operated directional ~ with spring return to resting position (mid-position) ......X2168 – Electropneumatically operated directional ~ with spring return....................X2167 – Float-operated ~ .........................................X2134 – Flow ~, pressure and temperature compensated..............................................X2216 X2217 – Flow ~, pressure compensated ..................X2214 X2215 – Flow ~, pressure compensated, with overflow to reservoir ...................................X2218 X2219 – Lever-operated directional ~, detained in all three positions....................................X2169 – Lever operated directional ~ with three positions and spring return to resting position (mid-position).....................X2163 – Manually operated directional ~, detained in both positions with restricted access to the actuator.................X2170 – Manually operated directional ~ with spring return to resting position ..................X2161 – Manually operated needle type ~ ...............X2137 – Manually or electrically operated directional ~ with spring return....................X2166 – Pneumatically operated directional ~ with spring return to resting position...........X2162 – Self-operating back-pressure ~ ..................X2132 – Self-operating pressure reducing ~ ............X2133 – with actuating device of electric motor type...................................................X2131 See also Directional control valve Control-switch – Manually operated ~...................................X685 – Manually operated ~ with manually disengaged latch ........................................X657 – Manually operated ~ with electrically disengaged latch ........................................X658 – Manually operated multi-position ~.............X656 – operated by lever with four operation directions ....................................................X684 – operated by pulling .....................................X682 – operated by pushing ...................................X681 – operated by pushing and pulling.................X683 – operated by turning.....................................X687 – operated by turning with automatic return from the two extreme positions ........X686 Controller – Feedback ~.................................................895 896 – Feedback ~ with internal set point adjustability.................................................X911 – Feedback ~ for rotational speed.................X912 – Feedback ~ with PID characteristic and many inputs .........................................X913 Controlling........................................................792 1053 Controlling unit – Hydraulic ~ .................................................X107
12
8-6.5.1.21 8-6.5.1.22 8-6.5.1.19 8-6.5.1.20 8-6.5.1.17 8-6.5.1.18 8-6.5.1.8 8-6.5.1.7 8-4.5.4.4 8-6.5.3.6 8-6.5.3.7 8-6.5.3.4 8-6.5.3.5 8-6.5.3.8 8-6.5.3.9 8-6.5.1.9 8-6.5.1.3 8-6.5.1.10 8-6.5.1.1 8-4.5.4.7 8-6.5.1.6 8-6.5.1.2 8-4.5.4.2 8-4.5.4.3 8-4.5.4.1 4-5.5.5 4-4.5.7 4-4.5.8 4-4.5.6 4-5.5.4 4-5.5.2 4-5.5.1 4-5.5.3 4-5.5.7 4-5.5.6 5-12.1.5 5-12.1.6 5-12.5.11 5-12.5.12 5-12.5.13 5-4.3.2.2 6-7.3.1.3 2-4.5.7
Description
RegisLocation tration (Partnumber subclause)
Conversion ......................................................111 112 – Devices for purification by ~ .......................– – of analogue flow rate signal to digital form ............................................................X1071 – of fluid or mechanical energy by intermediate fluid step: Devices for ~ .........– – of mechanical energy to fluid energy or vice versa: Devices for ~ ........................– – without connection between input and output circuits ......................................113 114 Converter – Adjustable hydraulic rotary torque ~...........X2431 – DC to DC ~.................................................X111 See also Pneumatic-hydraulic converter, Signal converter, Torque converter Converting .......................................................1075 Conveyor – Belt ~ with adjustable length.......................X3806 – connected to a feeding belt conveyor with scraper flights coming from below ......X3805 – Compressing screw ~.................................X3811 X3813 – Reversible ~ ...............................................X3802 – Uni-directional belt ~ driven by electric motor..............................................X3801 – with rotary vane feeder...............................X3812 Conveyors – Two ~ of roller type interlinked by a turntable .....................................................X3815 Conveyors and associated devices .................– Cooler – Air fin ~ with induced draft ..........................X2505 – Water-sprayed ~.........................................X2504 Cooling coil ......................................................2501 Cooling tower...................................................2521 X2521 – with forced draft..........................................X2523 – with induced draft .......................................X2522 Cooling towers.................................................– Correlation ......................................................263 – between the rotational direction of an hydraulic pump with alternative directions of flow and the direction of flow ..................X261 – between two motions..................................X260 – for a reversible liquid pump ........................X2307 – for a reversible hydraulic pump ..................X2408 Counter............................................................841 – Cam driven mechanical ~ with output closing at each n events .............................X877 – counting downwards with pre-set to n events......................................................X872 – Electromechanical ~...................................X873 – Electromechanical ~ indicating a new event when the electrical pulse disappears (postponed action) ...................X874 – Electromechanical ~ with electrical reset to 0 ....................................................X876 – Electromechanical ~ with manual reset to 0 ....................................................X875 – with reset to 0 .............................................X871 Counter-clockwise: See Anti-clockwise Counting devices .............................................– Coupling – Clamped flange ~ .......................................513 – Flange ~ .....................................................511 – Flexible ~ ....................................................512 – Quick-release ~ ..........................................X563
2-4.3.2.1 2-4.3.2.2 12-5 6-7.5.31 10-5 10-4 2-4.3.2.3 2-4.3.2.4 10-5.5.1 2-4.5.11 6-7.3.1.25 14-4.5.6 14-4.5.5 14-4.5.11 14-4.5.13 14-4.5.2 14-4.5.1 14-4.5.12 14-4.5.15 14-4 11-4.5.5 11-4.5.4 11-4.1.3 11-6.1.1 11-6.5.1 11-6.5.3 11-6.5.2 11-6 2-7.3.3 2-7.5.15 2-7.5.14 9-4.5.7 10-4.5.8 5-8.1.1 5-8.5.7 5-8.5.2 5-8.5.3 5-8.5.4 5-8.5.6 5-8.5.5 5-8.5.1 5-8 3-6.1.3 3-6.1.1 3-6.1.2 3-8.5.1
--`,,``,`-`-`,,`,,`,`,,`---
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
RegisLocation tration (Partnumber subclause)
Coupling element – Quick-release ~ of female type.................. 564 – Quick-release ~ of female type with automatic closing ....................................... 567 – Quick-release ~ of male type..................... 563 – Quick-release ~ of male type with automatic closing ....................................... 566 – Quick-release ~ which fits into another coupling element of the same type............ 565 – Quick-release ~ which fits into another coupling element of the same type with automatic closing................................ 568 Covered lorry, van........................................... 3869 Covered railway wagon or covered trailer....... 3872 Crane .............................................................. 3841 – Overhead, travelling crane ~ ..................... X3842 – travelling on two mono-rails ....................... X3841 Cranes, lifts, hoists, and materials handling robots .......................................... – Critical flow nozzle .......................................... 774 Critical flow nozzle type................................... 774 Cross-connection device................................. 3085 Cross-connection point with three pipelines, power or telecommunication lines ............. X3082 Crossing of symbols for connections .............. X401 Crushing – Size reduction by ~, breaking, or pulverisation............................................... 2808 Cryo pump ...................................................... 2339 Cushion........................................................... 2444 – Double-acting hydraulic cylinder with adjustable ~ on each side of the piston ..... X2444 Cyclone separator........................................... X2618 Cyclonic type................................................... 2621 Damper – Control ~ with double-acting fluid cylinder . X2153 – Multi-leaf ~ ................................................. X2151 – Three-way ~ with diaphragm actuator ....... X2152 – Two- or three-way ~................................... 2151 Dampers ......................................................... – DC to DC converter......................................... X111 De-superheater control valve, diaphragmoperated..................................................... X2136 De-superheater, humiditor .............................. X2503 Dead band ...................................................... 137 Deaerator – Boiler feedwater vessel with ~ ................... X2070 Decanter centrifuge......................................... X2620 Delay............................................................... 123 Delay device ................................................... 651 652 – with delay in both directions....................... 653 Delay element with switch-on delay................ X108 Delayed output................................................ X113 Density ............................................................ 1054 Desalination (desalting) plant.......................... X3209 Detector, pilot switch....................................... 3132 – Dust ~ ........................................................ X3137 – Earthquake ~ ............................................. X3144 – Fire ~.......................................................... X3135 – Heat (temperature) ~ ................................. X3132 – Light ~........................................................ X3134
Description – – – –
3-8.1.3 3-8.1.6 3-8.1.2 3-8.1.5 3-8.1.4 3-8.1.7 14-7.1.9 14-7.1.12 14-5.1.1 14-5.5.2 14-5.5.1 14-5 7-5.1.4 5-4.3.1.6 15-5.1.5 15-5.5.2 3-4.5.1 13-4.3.8 9-5.1.9 10-6.1.11 10-6.5.4 12-4.5.18 12-4.3.3 8-5.5.3 8-5.5.1 8-5.5.2 8-5.1.1 8-5 2-4.5.11 8-4.5.4.6 11-4.5.3 2-4.3.2.23 5-12.3.5 6-7.3.3.8 7-6.5.10 12-4.5.20 2-4.3.2.9 6-7.3.3.2 4-4.1.6 6-6.3.1 4-4.1.7 6-6.3.2 4-4.1.8 6-6.3.3 2-4.5.8 2-4.5.13 6-7.3.1.4 15-10.5.9 15-8.1.2 15-8.5.7 15-8.5.14 15-8.5.5 15-8.5.2 15-8.5.4
Motion ~......................................................X3138 Passage ~...................................................X3139 for pressure changes (burglar detector) .....X3141 for pressure higher than the setting value ...........................................................X3140 – Smoke ~ .....................................................X3136 – Sound ~ ......................................................X3133 – Vibration ~ ..................................................X3142 – Vibration ~ for vertical vibrations.................X3143 Detent for detaining in – discrete position..........................................655 – discrete position, shown in disengaged position .......................................................656 – discrete position, shown in engaged position .......................................................657 – any position ................................................659 – any position, drift to the left permitted.........660 Device for – averaging....................................................X903 – bias .............................................................X904 – blocking of electric current in a pipeline......X3011 – division........................................................X902 – high limitation..............................................X906 – high limitation, where the input value can be negative ..........................................X908 – low limitation ...............................................X907 – mixing .........................................................2671 – restricted access.........................................692 – reverse function ..........................................X905 – separating...................................................2601 – summing .....................................................X901 Device serving as heat pump or refrigerator ..................................................X2553 Devices (in general) .........................................– Devices for – analogue signal processing ........................– – conversion of fluid or mechanical energy by intermediate fluid step................– – conversion of mechanical energy to fluid energy or vice versa............................– – mixing .........................................................– – purification by conversion ...........................– – separating...................................................– – storage........................................................– – measurement, control, and protection ........– Diaphragm .......................................................2003 Diaphragm .......................................................2004 – -operated de-superheater control valve ...........................................................X2136 – Pressure vessel with ~................................X2073 – type.............................................................2003 2128 Diaphragm actuator – Double-acting ~ ..........................................726 – operating a valve ........................................X2101 X2102 X2132 – Single-acting ~............................................725 Difference.........................................................1054 Difference pressure transmitting and indication.....................................................X1054 Differential – amplifier ......................................................X910 – type.............................................................793 X768 Diffusion pump.................................................2332
15-8.5.8 15-8.5.9 15-8.5.11 15-8.5.10 15-8.5.6 15-8.5.3 15-8.5.12 15-8.5.13 4-4.1.11 6-6.3.5 4-4.1.12 4-4.1.13 4-4.1.15 6-6.3.6 4-4.1.16 6-6.3.7 5-12.5.3 5-12.5.4 15-4.5.11 5-12.5.2 5-12.5.6 5-12.5.8 5-12.5.7 12-6.1.1 4-5.1.12 5-12.5.5 12-4.1.1 5-12.5.1 11-8.5.3 2-4 5-12 10-5 10-4 12-6 12-5 12-4 7-6 15-8 7-4.1.9 7-4.1.10 8-4.5.4.6 7-6.5.13 5-4.3.1.3 8-4.3.2.8 4-6.1.16 8-4.5.1.1 8-4.5.1.2 8-4.5.4.2 4-6.1.15 6-7.3.1.4 6-7.5.14 5-12.5.10 5-4.3.2.3 5-4.5.18 9-5.1.2
13
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause)
--`,,``,`-`-`,,`,,`,`,,`---
Description
Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
Diffusion-ejector pump.....................................2333 Digital signal.....................................................235 – Conversion analogue to ~ ..........................X1071 Dimension – Change of pipe ~ ........................................516 Direct hydraulically operated directional control valve ...............................................X2164 X2165 Direction – Correlation between rotational and flow ~s of a hydraulic pump........................X261 – in general, except for energy and signal flow...................................................241 242 – Motor rotating in anti-clockwise ~ with pump in clockwise ~ ...................................X250 X251 – of circular motion ........................................255 – of mass flow in pipeline ..............................X242 – of mass flow in valve ..................................X243 – of propagation, energy, or signal flow (simplex) .....................................................249 – Unspecified ~ of circular motion .................254 – Working ~ of hydraulic power .....................243 – Working ~ of pneumatic power...................244 Directional control valve – Direct hydraulically operated ~ ...................X2164 – Direct hydraulically operated ~, different affecting areas ..............................X2165 – Direct pneumatically operated ~, spring return to resting position ..................X2162 – Directional leak-free control valve, two ports, two positions ..............................X2183 – Electrically operated ~ ................................X2177 X2178 – Electrohydraulically or manually operated ~, spring return ............................X2168 – Electropneumatically operated ~, spring return ...............................................X2167 – Leak-free ~ with two ports and two positions .....................................................X2183 – Lever-operated ~, detained in all positions .....................................................X2169 – Lever operated ~, three positions, spring return ...............................................X2163 – Manually operated ~, detained in both positions, restricted access to actuator. .....X2170 – Manually operated ~, spring return to resting position ...........................................X2161 – Manually or electrically operated ~, spring return ...............................................X2166 – with four ports and three distinct positions, automatic return to mid-position ................................................X2003 – with four positions, operated by lever, one stable position and automatic return from other positions..........................X688 – with pilot valve ............................................X2171 X2172 X2173 X2174 – with three ports, three positions..................X2181 X2182
14
9-5.1.3 2-6.1.15 6-4.3.6 6-7.5.31 3-6.1.6 8-6.5.1.4 8-6.5.1.5 2-7.5.15 2-7.1.1 14-4.3.2 15-10.3.3 2-7.1.2 2-7.5.5 2-7.5.6 2-7.1.13 12-4.3.2 2-7.5.1 2-7.5.2 2-7.1.7 6-4.3.2 2-7.1.12 12-4.3.1 2-7.1.3 2-7.1.4 8-6.5.1.4 8-6.5.1.5 8-6.5.1.2 8-6.5.1.23 8-6.5.1.17 8-6.5.1.18 8-6.5.1.8 8-6.5.1.7 8-6.5.1.23 8-6.5.1.9 8-6.5.1.3 8-6.5.1.10 8-6.5.1.1 8-6.5.1.6 7-4.5.3 4-5.5.8 8-6.5.1.11 8-6.5.1.12 8-6.5.1.13 8-6.5.1.14 8-6.5.1.21 8-6.5.1.22
Description
RegisLocation tration (Partnumber subclause)
– with three ports, two positions ....................X2179 X2180 Directional servo-control valve with negative overlapping in mid-position.........................X2176 Directional servo-control valve with positive overlapping in mid-position.........................X2175 Directions.........................................................– – Alternative ~ in general, except for energy and signal flow ..........................245 – Bidirectional, simultaneously ......................247 – Propagation, energy, or signal flow in two simultaneous ~ (full-duplex).................251 – Rectilinear motion in two ~ with dwell.........X257 See also Alternative directions Disc – Rupturing ~.................................................2035 – type.............................................................2126 – with knife ....................................................2606 Disc and plate (knife) separator.......................X2615 Dish-washer.....................................................X2624 Displacement type: See Positive ~ Displacer..........................................................771 – type.............................................................771 Display unit ......................................................851 Displaying discrete state..................................1052 Displays ...........................................................– Disposal plant – Waste ~ (waste tip).....................................X3215 Distribution centre............................................3083 Dividing ............................................................161 – by laser beam.............................................2814 – by sawing ...................................................2811 – by shearing.................................................2812 – material.......................................................2810 Division – Device for ~ ................................................X902 Dome – Boiler with ~................................................2532 Double L-bore in four-way valve ......................2115 Double-acting diaphragm actuator ..................726 Double-acting fluid cylinder – Actuator in form of ~...................................724 X713 X2153 – with adjustable cushions ............................X2444 – with double-ended piston rod .....................X2443 Double-acting hydraulic actuator .....................719 – with different active areas...........................721 Double-acting hydraulic cylinder......................2442 – different piston areas, adjustable cushions X2444 – of telescopic type........................................2450 Double-acting pneumatic actuator...................720 – with different active areas...........................722 Double-acting pneumatic cylinder ...................2448 – of telescopic type........................................2451 – with double-ended piston rod .....................X2443 Drain funnel .....................................................2040 Drain line..........................................................422 Drift – to the left permitted.....................................660 Drilling, boring..................................................2815 Driverless, automatic fork lift truck, including remote controlled ........................3863 Duct .................................................................405 – Closed end of ~ ..........................................503 – elements.....................................................–
8-6.5.1.19 8-6.5.1.20 8-6.5.1.16 8-6.5.1.15 2-7 14-4.3.3 14-4.3.4 2-7.1.9 6-4.3.4 2-7.5.12 7-5.1.9 8-4.3.2.6 12-4.1.7 12-4.5.15 12-4.5.24 7-4.1.6 5-4.3.1.2 5-9.1.1 6-7.3.1.2 5-9 15-0.5.15 15-5.1.3 2-4.3.3.1 6-7.3.3.15 13-4.3.14 13-4.3.11 13-4.3.12 13-4.3.10 5-12.5.2 11-7.1.2 8-4.3.1.9 4-6.1.16 4-6.1.14 4-6.5.3 8-5.5.3 10-6.5.4 10-6.5.3 4-6.1.9 4-6.1.11 10-6.1.5 10-6.5.4 10-6.1.9 4-6.1.10 4-6.1.12 10-6.1.6 10-6.1.10 10-6.5.3 7-5.1.14 3-4.1.10 4-4.1.16 6-6.3.7 13-4.3.15 14-7.1.3 3-4.1.5 3-5.1.3 7-5
--`,,``,`-`-`,,`,,`,`,,`---
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
– Insulated ~ ................................................. X322 – Planned ~ .................................................. 412 – Located in a rectangular ~ , for example, pipelines, conductors, or cables ................ 3055 – Pipeline or conductor within a six-pipe ~ .. X3002 – with thermal insulation ............................... X322 Duct or pipe – Located in a circular, ~ for example, conductors or cables.................................. 3054 Ducts – Group of ~.................................................. 406 – Group of planned ~.................................... 413 – Joint of ~ .................................................... 501 Ducts, Installation of pipelines and ~ .............. – Duplex: See Full-duplex Dust................................................................. 3144 – detector...................................................... X3137 Dwell – at return point............................................. X257 – Intermediate ~............................................ X255 – Intermediate ~, alternative directions......... X256 Earthquake detector........................................ X3144 Effect – Magnetic field ~.......................................... 119 – Proximity ~................................................. 121 – Touch ~...................................................... 122 Ejector pump................................................... 2331 Electric current – Device for blocking of ~ in a pipeline ......... X3011 Electric electrode type..................................... IEC Electric heating element type.......................... IEC Electric hot water generating plant.................. X3203 Electric induction liquid pump.......................... 2352 2353 Electric induction type ..................................... IEC Electric liquid pump......................................... 2351 Electric motor and pump, motor rotating anti-clockwise, pump rotating clockwise .... X250 X251 Electric pumps ................................................ – Electric thermal power and hot water generating plant – Combined ~ ............................................... X3204 Electric type..................................................... 435 3203 Electric variable............................................... 1055 Electric window foil.......................................... 3133 Electrically insulating mechanical link, shaft, wire .................................................. 404 – Flexible ~ ................................................... X404 Electro-thermal type........................................ IEC Electrode furnace............................................ X2536 Electrode type – Conductive ~.............................................. IEC – Electric ~.................................................... IEC Electrohydraulically operated two-stage pressure relief valve................................... X2196 X2197 Electrohydraulically or manually operated directional control valve with spring return to resting position (mid-position)................ X2168 Electromagnetic – Non-guided ~ beam ................................... 411 – separator.................................................... X2628 – type ............................................................ IEC Electromechanical all-or-nothing relay – some contacts delayed.............................. X653 – whole relay delayed ................................... X654
10.5.2 3-4.1.8 15-4.3.5 15-4.5.2 3-4.5.7 15-4.3.4 3-4.1.6 3-4.1.9 3-5.1.1 15-4 15-8.3.4 15-8.5.7 2-7.5.12 2-7.5.10 2-7.5.11 15-8.5.14 2-4.3.2.6 2-4.3.2.7 2-4.3.2.8 9-5.1.1 15-4.5.11 11-7.3.4 11-7.3.3 15-10.5.3 9-6.1.2 9-6.1.3 11-7.3.5 9-6.1.1 2-7.5.5 2-7.5.6 9-6 15-10.5.4 3-4.3.5 15-0.3.12 6-7.3.1.5 15-8.1.3 3-4.1.4 3-4.5.4 12-4.3.8 11-7.5.6 5-4.3.1.14 11-7.3.4 8-6.5.2.6 8-6.5.2.7 8-6.5.1.8 3-4.1.7 12-4.5.28 12-4.3.5 4-4.5.3 4-4.5.4
Description
RegisLocation tration (Partnumber subclause)
Electromechanical counter ..............................X873 – indicating when the pulse disappears (postponed action)......................................X874 – electrical reset to 0......................................X876 – manual reset to 0........................................X875 Electromechanical indicator.............................864 – with automatic return ..................................X893 – without automatic return (manual reset) .....X894 Electromechanical position indicator................865 Electropneumatically operated – contactor.....................................................X405 – control valve with spring return ...................X2167 Electrostatic – separator ....................................................X2627 – type.............................................................IEC Emergency acting ............................................1076 Emergency stop – Manual actuator with special shape ...........691 Enabling input ..................................................126 Enclosure.........................................................3084 – with amplifying equipment ..........................X3081 End – cap..............................................................518 – Closed ~ of pipeline or duct ........................503 Energy flow – Alternative directions of ~ ...........................250 – Direction of ~ ..............................................249 – Directions of ~ simultaneously in both directions possible ......................................251 Engines with reciprocating or rotary pistons ........................................................– Entrainment pumps..........................................– Entrance into a bundle .....................................603 Entrapment pump ............................................2335 Entrapment pumps ..........................................– Envelope (tank)................................................301 Envelopes ........................................................– Equipment........................................................101 – Escalator – function .......................................................3834 – going downwards and to the left.................X3819 – going downwards and to the right ..............X3817 – going upwards and to the left .....................X3818 – going upwards and to the right ...................X3816 Even flow – Liquid pump with substantially ~.................X2309 Events – Number of ~................................................1076 Exhaust valve – Pilot-operated non-return valve ..................X2233 Exit from a bundle ............................................603 Expansion – bellows........................................................533 – loop.............................................................531 – sleeve .........................................................532 External combustion engine ............................2583 Extremely – high.............................................................1084 1085 – low ..............................................................1089 1090
5-8.5.3 5-8.5.4 5-8.5.6 5-8.5.5 5-10.1.2 5-10.5.1 5-10.5.2 5-10.1.3 3-4.5.5 8-6.5.1.7 12-4.5.27 12-4.3.4 6-7.3.1.26 4-5.1.11 2-4.3.2.12 15-5.1.4 15-5.5.1 3-6.1.8 3-5.1.3 2-7.1.8 6-4.3.3 2-7.1.7 6-4.3.2 2-7.1.9 6-4.3.4 11-10 9-5 3-9.1.3 9-5.1.5 9-5 2-9.1.1 11-4.1.1 12-4.1.2 2-9 2-4.1.1 2-4 14-4.3.16 14-4.5.19 14-4.5.17 14-4.5.18 14-4.5.16 9-4.5.9 6-7.3.1.26 8-6.5.4.3 3-9.1.3 3-7.1.3 3-7.1.1 3-7.1.2 11-10.1.3 6-7.3.2.4 6-7.3.2.5 6-7.3.2.9 6-7.3.2.10
--`,,``,`-`-`,,`,,`,`,,`---
15
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
Extruding – Material forming by ~ or pultruding .............2806
--`,,``,`-`-`,,`,,`,`,,`---
Facsimile..........................................................151 Fan...................................................................2302 – with alternative directions of flow................2304 Feedback control – Flow rate ~..................................................X1101 X1108 – Flow rate ~ and automatic closing..............X1107 – Flow rate ~, square root value....................X1106 – of electric reactive power............................X1061 Feedback controller .........................................895 896 X911 – for rotational speed.....................................X912 – with PID characteristic and many inputs.....X913 Feeder – Screw ~ with feeding funnel .......................X3809 X3810 – Conveyor with vibrating rotary vane ~ ........X3814 – Vane ~ rotor................................................3807 Feeding funnel, hopper....................................3806 Feeding funnel – Screw feeder with ~ ...................................X3809 X3810 Female type – Quick-release coupling element of ~ ..........564 Filter.................................................................X2601 X2602 – Bag ~, candle ~, leaf ~, cartridge ~ ............X2606 – Bed ~, fixed type.........................................X2609 – Bed ~, fluidized type ...................................X2610 – Belt ~, roll ~ ................................................X2608 – Biologic ~....................................................X2634 – Centrifugal ~ ...............................................X2614 – Compression ~ ...........................................X2612 – press...........................................................X2611 – with rotating drum .......................................X2603 – with rotating drum and scraper...................X2604 – with spray ...................................................X2607 Filter element ...................................................2602 – Bed ~, fixed type.........................................2603 – Bed ~, fluidized type ...................................2604 Final controlling element – Automatic operation of ~ ............................1022 – Manual operation of ~.................................1021 Final controlling elements – Operation of ~.............................................– Finned tube......................................................2502 Fire 8.3.2 – detector.......................................................X3135 Fired heater .....................................................X2537 Fired type.........................................................2541
– Boiler of ~ ...................................................X2531 – Stove or water heater of ~ ..........................X3151 First aid fire hose reel ......................................3124 Fittings .............................................................– – for sensors and measuring transducers .....– Fixed portion of a connector pair .....................576 Flag..................................................................716 Flame arrestor .................................................2036
13-4.3.6 2-4.3.2.35 9-4.1.2 9-4.1.4 6-10.4 6-10.8 6-10.7 6-10.6 6-7.5.21 5-12.1.5 5-12.1.6 5-12.5.11 5-12.5.12 5-12.5.13 14-4.5.9 14-4.5.10 14-4.5.14 14-4.1.3 14-4.1.2
Description
Flange – Blind ~ pair .................................................517 Flange coupling, flange pair.............................511 – Clamped ~..................................................513 Flare.................................................................2591 Flexible coupling ..............................................512 Flexible, electrically insulating mechanical link, shaft ....................................................X404 Flexible mechanical link...................................X402 X403 Flexible pipeline, hose .....................................X411 X412 Flexible pipelines, two of them of flexible type.X413 Flexible type.....................................................444 452 Float-operated control valve ...........................X2134 Float type .........................................................715 Flocculation – Size enlarging by sintering, agglomeration, coagulation, or ~ ................2809 Flow – Approximately constant ~...........................223 – Burst of sinusoidal ~ ...................................226 – Constant ~..................................................221
14-4.5.9 14-4.5.10 3-8.1.3 12-4.5.1 12-4.5.2 12-4.5.6 12-4.5.9 12-4.5.10 12-4.5.8 12-4.5.34 12-4.5.14 12-4.5.12 12-4.5.11 12-4.5.3 12-4.5.4 12-4.5.7 12-4.1.3 12-4.1.4 12-4.1.5 6-6.1.2 6-6.1.1 6-6 11-4.1.4 3142 1515-8.5.5 15-10.3.9 11-7.5.7 11-7.3.2 12-4.3.9 15-9.3.1 15-10.3.9 11-7.5.1 15-9.5.1 15-7.4 3-7 5-5 3-8.1.8 7-4.1.5 7-5.1.10
222 – Hydraulic pump with pulse-shaped ~ .........X2410 – Hydraulic pump with sinusoidal ~...............X2411 – Pulse-shaped ~ ..........................................225 – Saw-tooth shaped ~ ...................................227 – Sinusoidal ~................................................224 – to open air ..................................................2174 Flow control valve – Pressure and temperature compensated ~...........................................X2216 X2217 – Pressure compensated ~ ...........................X2214 X2215 – Pressure compensated ~, with overflow to reservoir ..........................................X2218 X2219 Flow divider, pressure compensated ~............X2220 Flow elbow type...............................................776 Flow nozzle......................................................773 – Critical ~ .....................................................774 – Flow rate measuring transducer, sensor of ~ type..........................................X760 Flow nozzle type ..............................................773 – Critical ~ .....................................................774 Flow path – Closed ~ .....................................................2172 – Closed ~, leak-free .....................................2173 – Open ~ .......................................................2171 Flow straightener .............................................2032 Flow rate ..........................................................1056 – computing...................................................X1072 X1073 – feedback control .........................................X1104 X1108 – feedback control, square root.....................X1106 – feedback control, automatic closing ...........X1107 – indication ....................................................X1048
16
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause) 3-6.1.7 3-6.1.1 3-6.1.3 11-11.1.1 3-6.1.2 3-4.5.4 3-4.5.2 3-4.5.3 3-4.5.11 3-4.5.12 3-4.5.13 3-4.3.8 3-4.3.9 8-4.5.4.4 5-4.3.1.1 13-4.3.9 2-6.1.3 2-6.1.6 2-6.1.1 9-4.3.2 10-4.3.3 2-6.1.2 9-4.3.3 10-4.3.4 10-4.5.10 10-4.5.11 2-6.1.5 9-4.3.4 10-4.3.6 2-6.1.7 2-6.1.4 10-4.3.5 8-6.3.4 8-6.5.3.6 8-6.5.3.7 8-6.5.3.4 8-6.5.3.5 8-6.5.3.8 8-6.5.3.9 8-6.5.3.10 5-4.3.1.8 7-5.1.3 7-5.1.4 5-4.5.10 5-4.3.1.5 5-4.3.1.6 8-6.3.2 8-6.3.3 8-6.3.1 7-5.1.6 6-7.3.1.6 6-7.5.32 6-7.5.33 6-10.4 6-10.8 6-10.6 6-10.7 6-7.5.8
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
– measuring transducer, sensor of flow nozzle type................................................. X760 – sensor........................................................ X759 – transmitting and registering of ratio ........... X1053 Flow-target operated actuator......................... 716 Fluid cylinder – Actuating device, the main element of which is single-acting ~.......................... X741 – Actuator in the form of a doubleacting ~ ...................................................... X713 – Actuator in the form of a doubleacting ~ ...................................................... 724 – Actuator in the form of a singleacting ~ ...................................................... 723 See also Hydraulic cylinder, Pneumatic cylinder Fluid cylinders ................................................. – Fluid motor: See Hydraulic motor, Pneumatic motor Fluid motors .................................................... – Fluid-level-operated actuator .......................... 715 Force............................................................... 1073 – Approximately constant ~ .......................... 223 – Constant ~ ................................................. 221 222 – Pulse-shaped ~.......................................... 225 – Saw-tooth shaped ~................................... 227 – Sinusoidal ~ ............................................... 224
--`,,``,`-`-`,,`,,`,`,,`---
Flushing valve with pipe interrupter................. 3109 Folding – Material forming by bending or ~ ............... 2804 Forging – Material forming by ~ ................................. 2802 Fork lift truck.................................................... 3862 – Driverless, automatic~, including remote controlled ....................................... 3863 Four-way valve................................................ 2104 – with actuating device of electric motor type X2105 Fraction ........................................................... 1056 Fractionating column....................................... X2625 – with passage for gas.................................. X2626 Freezer............................................................ 2551 X2552 Freezers.......................................................... – Frequency ....................................................... 1069 Freshwater infiltration plant ............................. X3208 Full-duplex ...................................................... 251 Functional connection ..................................... 401 Functional links and junctions ......................... – Functional type – Pure ~ ........................................................ 431 Functional unit................................................. 101
Functional units............................................... – Functions ........................................................ –
Description
Funnel – Drain ~ ........................................................2040 Furnace............................................................2533 – Electrode ~ .................................................X2536 Furnaces..........................................................–
5-4.5.10 5-4.5.9 6-7.5.13 4-6.1.6 7-4.1.5 4-7.5.1 4-6.5.3 4-6.1.14 4-6.1.13 10-6 10-4 4-6.1.5 7-4.1.4 6-7.3.1.23 2-6.1.3 2-6.1.1 9-4.3.2 10-4.3.3 2-6.1.2 9-4.3.3 10-4.3.4 2-6.1.5 9-4.3.4 10-4.3.6 2-6.1.7 2-6.1.4 10-4.3.5 15-6.9 13-4.3.4 13-4.3.2 14-7.1.2 14-7.1.3 8-4.1.4 8-4.5.1.5 6-7.3.1.6 12-4.5.25 12-4.5.26 11-8.1.1 11-8.5.2 11-8 6-7.3.1.19 15-10.5.8 2-7.1.9 6-4.3.4 3-4.1.1 6-4.1.1 6-4 3-4.3.1 6-4.3.1 2-4.1.1 13-4.1.1 15-9.1.1 15-10.1.1 2-4 2-4
Gain – Amplifier with adjustable ~..........................X207 Gas ..................................................................322 Gas discharge tube – Protective ~.................................................X321 Gas holder .......................................................X2066 Gas pump ........................................................2302 – of positive displacement type .....................X2310 – with alternative directions of flow................2304 See also Pneumatic pump Gas turbine ......................................................2573 Gas turbines.....................................................– Gas-lift pump....................................................2334 Gate type .........................................................2124 Gauge ..............................................................1057 Gear pair – Mechanical ~ ..............................................2008 – Mechanical ~, higher rotational speed on the output side than that on the input side ....................................................X249 General purpose valves...................................– Generating plant – Electric hot water ~ .....................................X3203 – Heat-pump hot water ~...............................X3205 – Heat-pump refrigeration coolant ~ ..............X3206 – Hot water ~ .................................................X3201 – Hot water ~ fired type .................................X3202 Generator: See Tachometer generator, Steam generator, etc. Getter ion pump ...............................................2338 Getter pump.....................................................2335 2337 Globe type........................................................2121 – Non-return valve of ~ ..................................X2113 – Spring-loaded safety valve of ~ ..................X2114 – Two-way valve of ~ with quick-acting coupling ......................................................X2106 Glueing – Joining, for example, by riveting, ~ welding, brazing or soldering......................2823 Going between a storey above and a storey below, for example, pipeline, cable, or conductor bundle .........................3060 Going to a storey above, – for example, pipeline, cable, or conductor bundle ........................................3058 – Pipeline direction of flow upwards ..............X3004 X3005 – Pipeline ~ coming from a storey below; direction of flow upwards ............................X3008 X3009 Going to a storey below – for example, pipeline, cable, or conductor bundle. .......................................3059 – Pipeline ~; direction of flow downwards......X3006 X3007 Group of – pipelines, ducts...........................................406 – planned pipelines, ducts .............................413 Grouping – Label ~........................................................107
7-5.1.14 11-7.1.3 11-7.5.6 11-7 2-5.5.7 2-10.1.2 2-10.5.1 7-6.5.6 9-4.1.2 9-4.5.10 9-4.1.4 11-9.1.3 11-9 9-5.1.4 8-4.3.2.4 6-7.3.1.7 4-4.1.1 7-4.1.14 2-7.5.4 8-4 15-10.5.3 15-10.5.5 15-10.5.6 15-10.5.1 15-10.5.2 9-5.1.8 9-5.1.5 9-5.1.7 8-4.3.2.1 8-4.5.2.3 8-4.5.3.4 8-4.5.1.6 13-4.3.23 15-4.3.10 15-4.3.8 15-4.5.4 15-4.5.5 15-4.5.8 15-4.5.9 15-4.3.9 15-4.5.6 15-4.5.7 3-4.1.6 3-4.1.9 2-4.3.1.2
17
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause)
Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
Gravity slide – Spiral ~ .......................................................X3808 – Straight ~ ....................................................X3807 Gravity type......................................................3832 – Spiral ~ (sliding)..........................................3833 Grinding – Surface treatment by removal of material, for example, by, ~, honing, polishing, or sanding...................................2824 Guide bracket, for example, for pipelines ........3005 Half-duplex.......................................................250
--`,,``,`-`-`,,`,,`,`,,`---
Hand ................................................................1058 Hand-held shower............................................3108 Handle – Manual actuator in the form of a removable ~................................................686 Heat – exchanger type ...........................................2501 – pump hot water generating plant................X3205 – pump refrigeration coolant generating plant............................................................X3206 – pump type; temperature decrease .............3202 – pump type; temperature increase...............3201 – (temperature) detector................................X3132 – (temperature) sensor..................................X3131 – treatment, for example, annealing or tempering ...............................................2807 Heat exchanger ...............................................X2501 – of double-pipe type .....................................2515 – of floating type ............................................2512 – of plate type ................................................2516 – of spiral type ...............................................2517 – Regenerative pre-heater ............................2518 – type.............................................................2501 – with coil-shaped tubes ................................2514 – with straight tubes.......................................2511 – with three flow paths...................................X2502 – with U-shaped tubes...................................2513 Heat exchangers..............................................– – with specified design ..................................– Heat pump .......................................................2551 X2551 – Device serving as a ~ or refrigerator ..........X2553 Heat pumps .....................................................– Heater – Fired ~ ........................................................X2537 Heating – Electric ~ element type ...............................IEC Heating coil ......................................................2501 High .................................................................1081 – Extremely ~ ................................................1084 1085 – limitation: See below – or low..........................................................1091 – pressure alarm............................................X1062 – selection: Component selecting ~ ..............X106 – Very ~ .........................................................1082 1083 High limitation ..................................................133 134 – Device for ~ ................................................X906
14-4.5.8 14-4.5.7 14-4.3.14 14-4.3.15
Description
– Device for ~, input value can be negative......................................................X908 High-speed centrifuge .....................................X2619 Higher or lower quantity level – Transition to a ~..........................................132 Higher quantity level – Transition to a ~..........................................130
13-4.3.24 15-4.1.5 2-7.1.8 6-4.3.3 6-7.3.1.8 15-6.8 4-5.1.6 15-10.3.8 15-10.5.5 15-10.5.6 15-0.3.11 15-0.3.10 15-8.5.2 15-8.5.1 13-4.3.7 11-4.5.1 11-5.1.5 11-5.1.2 11-5.1.6 11-5.1.7 11-5.1.8 11-7.3.6 12-4.3.7 11-5.1.4 11-5.1.1 11-4.5.2 12-4.3.7 11-5.1.3 11-4 11-5 11-8.1.1 11-8.5.1 11-8.5.3 11-8 11-7.5.7 11-7.3.3 11-4.1.3 6-7.3.2.1 6-7.3.2.4 6-7.3.2.5 6-7.3.2.11 6-7.5.22 2-4.5.6 6-7.3.2.2 6-7.3.2.3 2-4.3.2.19 5-12.3.1 6-7.3.3.4 2-4.3.2.20 5-12.3.2 6-7.3.3.5 5-12.5.6
Highest value – Selection of ~..............................................138 Hoist, lift ...........................................................3842 Hoists...............................................................– Honing – Surface treatment by removal of material, for example, by grinding, ~, polishing, or sanding ..................................2824 Hopper.............................................................3806 Hose type ........................................................2129 Hot water generating plant...............................X3201 – Combined electric thermal power and ~.....X3204 – Electric ~.....................................................X3203 – fired type.....................................................X3202 – Heat-pump ~ ..............................................X3205 Humidifier.........................................................X2521 Humiditor .........................................................X2503 Humidity...........................................................1063 Hydrant – Above ground ~ .........................................3122 – Underground ~ ...........................................3121 – Wall ~ .........................................................3123 Hydrants and related devices ..........................– Hydraulic actuator – Double-acting ~ ..........................................719 – Double-acting ~ with different active areas ..........................................................721 – Single-acting ~............................................717 Hydraulic buffer................................................X2007 Hydraulic controlling unit..................................X107 Hydraulic cylinder – Double-acting ~ ..........................................2442 – Double-acting ~ of telescopic type .............2450 – Double-acting ~ with different piston areas and cushions ....................................X2444 – Single-acting ~ of extension type ...............2441 – Single-acting ~ of retraction type................2446 – Single-acting ~ of retraction type with spring return ...............................................X2442 – Single-acting ~ of telescopic type...............2443 Hydraulic motor................................................2405 – Actuator in the form of ~ .............................2407 – Reversible ~ ...............................................X2420 – Rotodynamic ~ ...........................................X2414 – Semi-rotary ~..............................................2415 – Stepping ~ ..................................................X2421 – with adjustable speed.................................X2415 – with alternative directions of flow................2407 – with anti-clockwise rotation.........................X2416 ...................................................................X2417 – with anti-clockwise rotation, independent direction of flow...........................................X2419 – with positive displacement with adjustable capacity.....................................X2413 X2418 Hydraulic power source: See Working direction of hydraulic power Hydraulic pump................................................2401
18
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause) 5-12.5.8 12-4.5.19 2-4.3.2.18 11-8.3.3 2-4.3.2.16 11-8.3.1 2-4.3.2.24 6-7.3.3.9 14-5.1.2 14-5
13-4.3.24 14-4.1.2 8-4.3.2.9 15-10.5.1 15-10.5.4 15-10.5.3 15-10.5.2 15-10.5.5 11-6.5.1 11-4.5.3 6-7.3.1.13 15-7.2 15-7.1 15-7.3 15-7 4-6.1.9 4-6.1.11 4-6.1.7 7-4.5.7 2-4.5.7 10-6.1.5 10-6.1.9 10-6.5.4 10-6.1.1 10-6.1.3 10-6.5.2 10-6.1.7 10-4.1.5 4-6.1.17 10-4.5.20 10-4.5.14 10-4.1.15 10-4.5.21 10-4.5.15 10-4.1.7 10-4.5.16 10-4.5.17 10-4.5.19 10-4.5.13 10-4.5.18 10-4.1.1
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
RegisLocation tration (Partnumber subclause)
– driven by a shaft with adjustable speed ......................................................... X2404 – of uni-flow type........................................... X2409 – Over-centre ~, adjustable capacity ............ X2407 – Reversible ~............................................... X2408 – Rotodynamic ~, external leakage .............. X2403 – with alternative directions of flow ............... 2403 – with built-in electric motor (wet rotor)......... X2425 – with clockwise rotation ............................... X2405 X2406 – with positive displacement, adjustable capacity...................................................... X2402 X2401 – with positive displacement, pulsating flow ............................................................ X2410 – with positive displacement, sinusoidal flow ............................................................ X2411 See also Liquid pump Hydraulic pump/motor..................................... 2409 – with alternative directions of flow ............... 2413 – with anti-clockwise rotation ........................ X2422 X2423 – with different directions of flow................... 2411 Hydraulic rotary torque converter.................... 2434 – Adjustable ~............................................... X2431 Hydraulic semi-rotary motor............................ 2415 X2412 Hydraulic stepping motor ................................ X2421 Hydraulic torque converter – Adjustable ~............................................... X2431 Hydraulic type ................................................. 434 Hygienic valve................................................. X2241 X2242 X2243 X2244 Hygienic valves ............................................... – Hysteresis ....................................................... 124 Identical branches – Connection with n parallel, ~...................... 601 – Connection with three parallel ~ ................ X601 Identical items – Three ~ ...................................................... 343 – Two ~......................................................... 342 – Two or more ~ ........................................... 344 345 Impact on process........................................... 1072 In-line rotary mixer .......................................... X2672 In-line static mixer ........................................... X2673 Indicating......................................................... 148 1059 – and transmitting of level, registering, alarming ..................................................... X1065 – measuring instrument ................................ 832 Indication – Correlation ~ .............................................. 263 – Measuring point inside vessel, temperature transmitting and ~.................. X1059 – of affected area.......................................... 2177 – of differential pressure ............................... X1054 – of flow rate ................................................. X1048 – of level in vessel ........................................ X1957 – of level in vessel by viewing....................... X1058 – of position without detention ...................... 658 – of positions of controlled element .............. 701 702 703 704
10-4.5.4 10-4.5.9 10-4.5.7 10-4.5.8 10-4.5.3 10-4.1.3 10-4.5.25 10-4.5.5 10-4.5.6 10-4.5.2 10-4.5.1 10-4.5.10 10-4.5.11 10-4.1.9 10-4.1.13 10-4.5.22 10-4.5.23 10-4.1.11 10-5.1.5 10-5.5.1 10-4.1.15 10-4.5.12 10-4.5.21 10-5.5.1 3-4.3.4 8-7.5.1 8-7.5.2 8-7.5.3 8-7.5.4 8-7 2-4.3.2.10 6-7.3.3.3 3-9.1.1 3-9.5.1 2-11.1.3 2-11.1.2 2-11.1.4 2-11.1.5 6-7.3.1.22 12-6.5.2 12-6.5.3 2-4.3.2.32 6-7.3.1.9 6-7.5.25 5-7.1.2 2-7.3.3 6-7.5.19 8-6.3.7 6-7.5.14 6-7.5.8 6-7.5.17 6-7.5.18 4-4.1.14 4-5.3.1 4-5.3.2 4-5.3.3 4-5.3.4
Description
– Temperature ~ and control performed by computer with backup by discrete device ..........................X1081 – Temperature ~ in a central control room ...........................................................X1075 – Temperature ~ in a central control room; instrument not accessible to operator ......................................................X1076 – Temperature ~ in a local control room or on a local control panel...........................X1077 Indication and feedback control of reactive power ............................................X1061 Indicator – Electromechanical position ~......................865 – Electromechanical ~ ...................................864 – Electromechanical ~ with automatic return ..........................................................X893 – Electromechanical ~ without automatic return (manual reset) ..................................X894 – Mechanical ~ ..............................................863 – Over-current relay with mechanical ~ without automatic return (manual reset) .....X895 Induction – Electric ~ pump...........................................2352 2353 – Electric ~ type .............................................IEC Industrial truck..................................................3861 Industrial trucks, vehicles, and cargo ships .....– Infiltration plant – Freshwater ~...............................................X3208 Infinite number of intermediate positions of valve .......................................................2175 X1026 Information.......................................................3062 Information bus – of bidirectional type.....................................443 – of unidirectional type...................................442 Information processing function.......................1041 – performed by time-sharing..........................1042 – with enabling...............................................X1043 – with negated enabling (disabling) ...............X1044 – with negated input ......................................X1041 – with negated output ....................................X1042 – with retained output signal..........................X1045 Information processing functions .....................– Inherent variability............................................204 – Non-linear ~ ................................................205 Input – by keyboard ................................................153 – Compensating ~ .........................................127 – Enabling ~...................................................126 – for auxiliary power supply ...........................183 – label ............................................................106 Input and output circuits – Signal converter, measuring transducer without connection between ~ ....................755 756 Insertion pipe ...................................................802 – Boss with ~ .................................................803 – Temperature sensor in an ~ .......................X802 Inspection well – Circular-shaped access chamber, ~ ..........3087 Installation of pipelines and ducts ....................– Instrument – Indicating ~ .................................................832 – Integrating ~................................................834 – Recording ~ ................................................833 Insulated pipeline or duct .................................X322
6-9.5.1 6-7.5.35 6-7.5.36 6-7.5.37 6-7.5.21 5-10.1.3 5-10.1.2 5-10.5.1 5-10.5.2 5-10.1.1 5-10.5.3 9-6.1.2 9-6.1.3 11-7.3.5 14-7.1.1 14-7
15-10.5.8 8-6.3.5 6-6.5.6 15-4.3.12 3-4.3.7 3-4.3.6 6-7.1.1 6-7.1.2 6-7.5.3 6-7.5.4 6-7.5.1 6-7.5.2 6-7.5.5 6-7 2-5.1.4 2-5.1.5 2-4.3.2.37 2-4.3.2.13 2-4.3.2.12 2-4.3.5.3 2-4.3.1.1 5-4.1.5 5-4.1.6 5-5.1.2 5-5.1.3 5-5.5.2 15-5.1.7 15-4 5-7.1.2 5-7.1.4 5-7.1.3 2-10.5.2
19
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause)
--`,,``,`-`-`,,`,,`,`,,`---
Description
Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
Insulating – Electrically ~ mechanical link, shaft, wire ...404 – material.......................................................325 Insulation – Jacketed (sleeved) pipeline with thermal ~ ....................................................X410 – Pipeline or duct with thermal ~ ...................X322 – Pipeline with thermal ~, heated or cooled by a separate circuit........................X408 Integral, total ....................................................1067 Integrating........................................................1067 Integrating measuring instrument ....................834 Intensifier – Continuous pneumatic-hydraulic pressure ~ ..................................................2436 – Linear pneumatic-hydraulic pressure ~ ......2432 Interlocking device ...........................................666
--`,,``,`-`-`,,`,,`,`,,`---
Intermediate dwell – Rectilinear motion in alternative directions with ~..........................................X256 – Rectilinear motion with ~ ............................X255 Intermediate positions – Infinite number of ~ of valve .......................2175 Intermediate stop – Rectilinear motion with ~ ............................X254 Internal combustion engine..............................2582 – with reciprocating piston(s).........................X2581 – with rotating pistons....................................X2582 Internal connection ..........................................451 – in a pressure relief valve.............................X435 Inversion – Logic ~........................................................182 Ion exchange separator ...................................X2633 Ion exchange type ...........................................2624 Ionizing radiation – Sensor for ~................................................X764 – type.............................................................IEC Item – One ~ only ..................................................341 Items – Three identical ~.........................................343 – Two Identical ~ ...........................................342 – Two or more identical ~ ..............................344 345 Jacket ..............................................................2131 Jacketed (sleeved) pipeline .............................X409 – with thermal insulation ................................X410 Jet motor..........................................................2574 – Turbo-fan ~.................................................2575 Joining, for example, by riveting, glueing, welding, brazing or soldering......................2823 Joint – screwed ......................................................514 – Underground ~ of pipeline or cable ............X3001 – welded, brazed, or soldered .......................515 Joint of – connections ................................................501 – multiple electrically insulating mechanical links .........................................X509 – multiple functional links, links, or pipelines .....................................................X506 – mechanical parts permitting motion of the parts in two or more dimensions...........2005 Junction box, connection box, .........................3081
3-4.1.4 2-10.1.3 3-4.5.10 3-4.5.7 3-4.5.8 6-7.3.1.17 6-7.3.1.17 5-7.1.4 10-5.1.4 10-5.1.3 4-4.1.22 6-6.3.10 2-7.5.11 2-7.5.10 8-6.3.5 2-7.5.9 11-10.1.2 11-10.5.1 11-10.5.2 3-4.3.16 3-4.5.18 2-4.3.5.2 12-4.5.33 12-4.3.12 5-4.5.14 11-7.3.1 2-11.1.1 2-11.1.3 2-11.1.2 2-11.1.4 2-11.1.5 8-4.3.2.11 3-4.5.9 3-4.5.10 11-9.1.4 11-9.1.5 13-4.3.23 3-6.1.4 15-4.5.1 3-6.1.5 3-5.1.1 6-4.1.2 3-5.5.9 3-5.5.6 3-5.1.2 7-4.1.11 15-5.1.1
Description
Key – Manual actuator in the form of a ~..............687 Keyboard – Input by ~....................................................153 Knife – Disc with ~ ..................................................2606 L-bore – Double ~ in four-way valve .........................2115 – in three- or four-way valve ..........................2113 Label – Input or output ~ .........................................106 Label grouping .................................................107 X114 Latching device................................................661 – Control-switch with ~ ..................................X657 – shown in disengaged position ....................662 – shown in engaged position.........................663 Laser – Dividing by ~ beam.....................................2814 – generator ....................................................IEC Lathe 13-4.5.2 Launcher..........................................................2042 Lavatory – Public ~.......................................................X3214 Leaf filter ..........................................................X2606 Leak-free valve – Closed flow path of ~..................................2173 Leakage connection Hydraulic pump with ~ .....................................X2403 Length..............................................................1057 Level ................................................................1062 – computing...................................................X1074 – indication ....................................................X1057 – operated actuator .......................................715 – sensor.........................................................X751 – Transition to a higher or lower quantity ~ ...132 – Transition to a higher quantity ~ .................130 – Transition to a lower quantity ~ ..................131 Level measuring transducer – of float type.................................................X752 – of optical type, separate source .................X755 – of sonic type, integral source......................X753 – of sonic type, separate source ...................X754 Lever – Control-switch operated by ~, four operation directions ....................................X684 – Directional control valve, operated by ~ .....X688 – Manual actuator in form of ~.......................688 Lever-operated directional control valve – detained in all positions ..............................X2169 – three positions with spring return to resting position (mid-position).....................X2163 Lift, hoist ..........................................................3842 Lifts ..................................................................– Lift-type non-return valve .................................X2113 Light – alarm ..........................................................3067 – detector ......................................................X3134 Limit .................................................................261 Limitation – Device for high ~ ........................................X906 – Device for high ~, input value can be negative......................................................X908
20
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause) 4-5.1.7 2-4.3.2.37 12-4.1.7 8-4.3.1.9 8-4.3.1.7 2-4.3.1.1 2-4.3.1.2 2-4.5.14 4-4.1.17 6-6.3.8 4-4.5.7 4-4.1.18 4-4.1.19 13-4.3.14 13-4.3.13 X2802 7-5.1.16 15-0.5.14 12-4.5.6 8-6.3.3 10-4.5.3 6-7.3.1.7 6-7.3.1.12 6-7.5.34 6-7.5.17 4-6.1.5 5-4.5.1 2-4.3.2.18 11-8.3.3 2-4.3.2.16 11-8.3.1 2-4.3.2.17 11-8.3.2 5-4.5.2 5-4.5.5 5-4.5.3 5-4.5.4 4-5.5.4 4-5.5.8 4-5.1.8 8-6.5.1.9 8-6.5.1.3 14-5.1.2 14-5 8-4.5.2.3 15-4.3.17 15-8.5.4 2-7.3.1 5-12.5.6 5-12.5.8
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
– Device for low ~ ......................................... X907 – High ~ ........................................................ 133 134 – Low ~ ......................................................... 135 136
--`,,``,`-`-`,,`,,`,`,,`---
– of high values of flow rate signal................ X1069 Limited circular motion in alternative directions ................................................... X253 Linear fluid motor – Double-acting ~ ......................................... 724 – Double-acting, hydraulic ~ ......................... 2442 – Single-acting ~........................................... 723 2441 – Single-acting ~ of hydraulic, telescopic type ............................................................ 2443 Linear fluid motors .......................................... – Linear pneumatic-hydraulic converter............. 2431 Linear pneumatic-hydraulic pressure intensifier ................................................... 2432 Link – Electrically insulating mechanical ~ ........... 404 – Flexible, electrically insulating mechanical ~ ............................................. X404 – Flexible ~ ................................................... X402 X403 – Mechanical ~ ............................................. 402 403 Links – Joint of two mechanical parts permitting motion in two or more dimensions................................................. 2005 Liquid .............................................................. 321 Liquid pump .................................................... 2301 – driven by shaft with adjustable speed........ X2303 – Electric induction ~..................................... 2352 2353 – Electric ~.................................................... 2351 – of over-centre type..................................... X2306 – of positive displacement type, adjustable capacity .................................... X2301 – of uni-flow type........................................... X2308 – Reversible ~............................................... X2307 – Rotodynamic ~ with adjustable capacity, actuator shown ........................... X2302 – with substantially even flow ....................... X2309 – with alternative directions of flow ............... 2303 – with built-in electric motor (wet rotor)......... X2311 – with clockwise rotation ............................... X2304 X2305 See also Hydraulic pump Loader – Log ~.......................................................... 3866 – Wheel ~ ..................................................... 3865 Local control panel – Auxiliary location in a local control room or on a ~ ........................................... 1104 – Primary location in a local control room or on a ~ ........................................... 1103
5-12.5.7 2-4.3.2.19 5-12.3.1 6-7.3.3.4 2-4.3.2.20 5-12.3.2 6-7.3.3.5 2-4.3.2.21 5-12.3.3 6-7.3.3.6 2-4.3.2.22 5-12.3.4 6-7.3.3.7 6-7.5.29 2-7.5.8 4-6.1.14 10-6.1.5 4-6.1.13 10-6.1.1 10-6.1.7 10-6 10-5.1.1 10-5.1.3 3-4.1.4 3-4.5.4 3-4.5.2 3-4.5.3 3-4.1.2 3-4.1.3
3-5.1.2 2-10.1.1 15-10.3.4 9-4.1.1 15-10.3.7 9-4.5.3 9-6.1.2 9-6.1.3 9-6.1.1 9-4.5.6 9-4.5.1 9-4.5.8 9-4.5.7 9-4.5.2 9-4.5.9 9-4.1.3 9-4.5.11 9-4.5.4 9-4.5.5
Description
– Temperature indication in a local control room or on a ~ ................................X1077 Local control room – Auxiliary location in a ~ or on a local control panel ...............................................1104 – Primary location in a ~ or on a local control panel ...............................................1103 – Temperature indication in a ~ or on a local control panel....................................X1077 Located – in a circular duct or pipe, for example, conductors or cables ..................................3054 – in a rectangular duct, for example, pipelines, conductors, or cables .................3055 – on a tray, for example, pipelines, conductors, or cables; endpoints indicated. ....................................................3056 – on a tray, for example, pipelines, conductors, or cables; continuous ..............3057 – on poles, for example, pipeline, cable, or power line.....................................3053 – underground, for example, pipeline, cable, or joint .............................................3051 – underwater, for example, pipeline or cable.......................................................3052 Location – Auxiliary ~ in a central control room ...........1102 – Auxiliary ~ in a local control room or on a local control panel...............................1104 – Primary ~ in a central control room.............1101 – Primary ~ in a local control room or on a local control panel...............................1103 Locomotive ......................................................3875 Log loader........................................................3866 Logic – AND-function ..............................................142 – – – –
elements (Binary ~) ....................................– functions (Binary ~).....................................– inversion .....................................................182 negation......................................................181
– OR-function ................................................143 Loop – Expansion ~................................................531 Lorry.................................................................3868 Low ..................................................................1086 – Device for ~ limitation .................................X907 – Extremely ~.................................................1089 1090 – High or ~ .....................................................1091 – limitation......................................................135 136 – Very ~ .........................................................1087 1088 Lower quantity level – Transition to ~.............................................131
14-7.1.6 14-7.1.5
Lowest value – Selection of ~..............................................139
6-7.3.4.4 6-7.3.4.3
Lubricator – Air ~ ............................................................X2674
6-7.5.37 6-7.3.4.4 6-7.3.4.3 6-7.5.37 15-4.3.4 15-4.3.5 15-4.3.6 15-4.3.7 15-4.3.3 15-4.3.1 15-4.3.2 6-7.3.4.2 6-7.3.4.4 6-7.3.4.1 6-7.3.4.3 14-7.1.15 14-7.1.6 2-4.3.2.28 6-7.3.3.12 5-11 6-8 2-4.3.5.2 2-4.3.5.1 6-7.3.3.18 2-4.3.2.29 6-7.3.3.13 3-7.1.1 14-7.1.8 6-7.3.2.6 5-12.5.7 6-7.3.2.9 6-7.3.2.10 6-7.3.2.11 2-4.3.2.21 5-12.3.3 6-7.3.3.6 2-4.3.2.22 5-12.3.4 6-7.3.3.7 6-7.3.2.7 6-7.3.2.8 2-4.3.2.17 11-8.3.2 2-4.3.2.25 6-7.3.3.10 12-6.5.4
21
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause)
Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
--`,,``,`-`-`,,`,,`,`,,`---
Magnet – Permanent ~...............................................326 – Permanent ~ type .......................................326 Magnetic field effect.........................................119 Male type – Quick-release coupling element of ~ ..........563 Manual .............................................................1058 Manual actuator ...............................................681 – in form of a key...........................................687 – in form of a lever.........................................688 – in form of a pedal........................................689 – in form of a removable handle ....................686 – in form of a treadle......................................690 – operated by pulling .....................................683 – operated by pushing ...................................682 – operated by pushing and pulling.................684 – operated by turning.....................................685 – with special shape for safety purpose.......................................................691 Manual operation of – final controlling element..............................1021 – valve ...........................................................X1021 – valve with automatic return to closed position .......................................................X1022 – valve with delayed automatic return to closed position............................................X1023 – valve with infinite number of stable positions .....................................................X1025 – valve with two stable positions ...................X1024 Manual, remote control of – control valve with indication of set value ...........................................................X1103 – valve with infinite number of stable positions, indication of valve position .........X1102 – valve with automatic return to closed position .......................................................X1101 Manual reset – Electromechanical counter with ~ to 0........X875 Manual setting of set value of feedback control function ...........................................X1047 Manual switching .............................................X1046 Manually operated – actuators.....................................................– – control-switch..............................................X685 – directional control valve: See below – multi-position control-switch .......................X656 – needle type control valve............................X2137 Manually operated control-switch – with electrically disengaged latch ...............X658 – with manually disengaged latch .................X657 Manually operated directional control valve – detained in both positions, restricted access to actuator. .....................................X2170 – with spring return to resting position...........X2161 Manually or electrically operated directional control valve with spring return...................X2166 Manually or electrohydraulically operated directional control valve with spring return to resting position (mid-position) ......X2168 Machine tools...................................................– Mass flow – Direction of ~ in pipeline .............................X242 – Direction of ~ in valve .................................X243 Master clock.....................................................843 Material forming by – bending or folding .......................................2804 – extruding or pultruding................................2806 – forging.........................................................2802 – pressing ......................................................2803
2-10.1.4 12-4.3.6 2-4.3.2.6 3-8.1.2 6-7.3.1.8 4-5.1.1 4-5.1.7 4-5.1.8 4-5.1.9 4-5.1.6 4-5.1.10 4-5.1.3 4-5.1.2 4-5.1.4 4-5.1.5 4-5.1.11 6-6.1.1 6-6.5.1 6-6.5.2 6-6.5.3 6-6.5.5 6-6.5.4 6-10.3 6-10.2 6-10.1 5-8.5.5 6-7.5.7 6-7.5.6 4-5 4-5.5.5 4-4.5.6 8-4.5.4.7 4-4.5.8 4-4.5.7 8-6.5.1.10 8-6.5.1.1 8-6.5.1.6 8-6.5.1.8 13-4 2-7.5.1 2-7.5.2 5-8.1.3 13-4.3.4 13-4.3.6 13-4.3.2 13-4.3.3
Description
– rolling ..........................................................2805 Material of other type .......................................328 Materials ..........................................................– – handling robot.............................................3843 Measurement – in pipeline ...................................................X1012 – inside pressure vessel................................X1011 – Point of ~ ....................................................1011 – – Torque ~ .....................................................795 Measuring instrument – Indicating ~ .................................................832 – Integrating ~ ...............................................834 – Recording ~ ................................................833 Measuring instruments ....................................– Measuring point inside vessel, temperature transmitting and indication..........................X1059 Measuring transducer......................................753 754 759 796 – for angle .....................................................X769 – for flow rate.................................................X760 – for pressure ................................................X758 – for temperature, voltage as output, contact closing when temperature is greater than set value.................................X770 – Level ~ of float type ....................................X752 – Level ~ of optical type, separate source.....X755 – Level ~ of sonic type, integral source .........X753 – Level ~ of sonic type, separate source.......X754 – Position ~ of differential transformer type...X768 – Pressure ~..................................................X758 – Signal converter or ~ ..................................X765 – Temperature ~ with built-in sensor of semiconductor type ....................................X762 – utilizing the synchro effect ..........................760 – without connection between input and output circuits .............................................755 756 Measuring transducers ....................................– Measuring transformers...................................– Mechanical elements.......................................– Mechanical gear pair .......................................2008 – with higher rotational speed on the output side than that on the input side........X249 Mechanical indicator........................................863 – in over-current relay....................................X895 Mechanical link ................................................402 403 – Electrically insulating ~ ...............................404 – Flexible ~ ....................................................X402 X403 – Flexible, electrically insulating ~ .................X404 – Joint of ~s...................................................501 Mechanically driven – compressors...............................................– – compressors for fluid power .......................– – fans.............................................................– – pumps.........................................................– – pumps for fluid power .................................– Membrane .......................................................2003 2004 Membrane type................................................2003 Milling...............................................................2821 Mixer................................................................X2671 – In-line rotary ~ ............................................X2672 – In-line static ~ .............................................X2673
22
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause) 13-4.3.5 2-10.1.6 2-10 14-5.1.3 6-5.5.2 6-5.5.1 6-5.1.1 6-5 5-4.3.2.5 5-7.1.2 5-7.1.4 5-7.1.3 5-7 6-7.5.19 5-4.1.3 5-4.1.4 5-4.1.8 5-4.3.2.6 5-4.5.19 5-4.5.10 5-4.5.8 5-4.5.20 5-4.5.2 5-4.5.5 5-4.5.3 5-4.5.4 5-4.5.18 5-4.5.8 5-4.5.15 5-4.5.12 5-4.1.9 5-4.1.5 5-4.1.6 5-4 5-6 7-4 4-4.1.1 7-4.1.14 2-7.5.4 5-10.1.1 5-10.5.3 3-4.1.2 3-4.1.3 3-4.1.4 3-4.5.2 3-4.5.3 3-4.5.4 3-5.1.1 9-4 10-4 9-4 9-4 10-4 7-4.1.9 7-4.1.10 5-4.3.1.3 13-4.3.21 12-6.5.1 12-6.5.2 12-6.5.3
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
Mixing – Device for ~ ............................................... 2671 – Devices for ~.............................................. – Mixing element – rotary.......................................................... 2672 – static .......................................................... 2673 Mixing outlet tap.............................................. 3104 – in taphole ................................................... 3105 – on wall........................................................ 3106 Moisture .......................................................... 1063 Momentarily .................................................... 1063 Momentary and partial reversal of motion....... 262 Monitoring – Television transmission and ~ ................... X1060 Mono-rail ......................................................... 3851 – Crane travelling on two ~s ......................... X3841 Motion – in alternative directions, circular................. 256 – Approximately constant ~ .......................... 223 – Constant ~ ................................................. 221 --`,,``,`-`-`,,`,,`,`,,`---
222 – detector...................................................... X3138 – Direction of circular ~ ................................. 255 – Limited circular ~ in alternative directions ................................................... X253 – Momentary and partial reversal of ~ .......... 262 – Oscillating ~ ............................................... 228 – Pulse-shaped ~.......................................... 225 – Reciprocating ~.......................................... X252 – Rectilinear ~ with alternative directions and intermediate dwell ....................... X256 – Rectilinear ~ with dwell at the return point ........................................................... X257 – Rectilinear ~ with intermediate dwell ......... X255 – Rectilinear ~ with intermediate stop........... X254 – Rectilinear ~ with partial reversal at an intermediate position............................. X258 – Saw-tooth shaped ~................................... 227 – Sinusoidal ~ ............................................... 224 – Unspecified direction of circular ~.............. 254 Motions – Correlation between two ~......................... X260 Motor and pump – Electric ~; motor rotating anti-clockwise, pump clockwise ......................................... X250 X251 Motors: See Electric motors, Fluid motors, Hydraulic motors, Pneumatic motors, etc. Moulding – Casting or ~ ............................................... 2801 Movable portion of connector pair................... 577 Moving part of non-return valve ...................... 2163 Multi-function................................................... 1071 Multi-leaf damper ............................................ X2151 Multi-line representation – Transition between ~ and single-line representation............................................ 602 Multi-position control-switch ............................ X656 Multi-variable................................................... 1071 Multiplying ....................................................... 1073
Description
Needle type......................................................2125 Needle type control valve – Manually operated ~ ...................................X2137 Negation (Logic ~) ...........................................181
12-6.1.1 12-6 12-6.1.2 12-6.1.3 15-6.4 15-6.5 15-6.6 6-7.3.1.13 6-7.3.1.13 2-7.3.2 6-7.5.20 14-6.1.1 14-5.5.1
Negative-going pulse .......................................230 Negative-going step.........................................232 Non-guided, electromagnetic beam.................411 Non-ionizing, electromagnetic radiation – Sensor for ~ ................................................X763 Non-linear adjustability.....................................202 Non-linear, inherent variability .........................205 Non-return function ..........................................2111 Non-return valve – Combined ~ and manually actuated stop valve ...................................................X2112 – Moving part of a ~.......................................2163 – of globe type; lift-type..................................X2113 – of swing-type ..............................................X2114 – Pilot-controlled double ~ .............................X2234 – Pilot-operated ~ closed by pilot pressure......................................................X2232 – Pilot-operated ~ opened by pilot pressure against return spring....................X2233 – Seat of ~ .....................................................2162 – Spring-loaded ~ ..........................................X2231 – Spring-loaded ~ of ball type........................X2115 – Weight-loaded ~ .........................................X2111 Nozzle – Critical flow ~ ..............................................774 – Critical flow ~ type ......................................774 – Flow ~ .........................................................773 – Flow ~ type .................................................773 – Spray ~ .......................................................2037
2-7.1.14 2-6.1.3 2-6.1.1 9-4.3.2 10-4.3.3 2-6.1.2 9-4.3.3 10-4.3.4 15-8.5.8 2-7.1.13 12-4.3.2 2-7.5.8 2-7.3.2 2-6.1.8 2-6.1.5 9-4.3.4 10-4.3.6 2-7.5.7
Nuclear reactor, hot-water type........................X2532 Nuclear type.....................................................IEC Number of events ............................................1076
2-7.5.11 2-7.5.12 2-7.5.10 2-7.5.9 2-7.5.13 2-6.1.7 2-6.1.4 10-4.3.5 2-7.1.12 12-4.3.1 2-7.5.14 2-7.5.5 2-7.5.6
13-4.3.1 3-8.1.9 8-6.1.3 6-7.3.1.21 8-5.5.1 3-9.1.2 4-4.5.6 6-7.3.1.21 6-7.3.1.23
One item only...................................................341 Open air – Flow to ~ .....................................................2174 Open bunker ....................................................X2074 Open flow path.................................................2171 Open store .......................................................2065 Operation – Automatic ~.................................................144 – Automatic ~ of final controlling element......1022 – Automatic ~ of pump...................................X1031 – Automatic ~ of valve ...................................X1026 X1027 X1028 X1029 X1030 X1032 X1033 X1034 X1035 X1036 – Manual ~ of final controlling element ..........1021 – Manual ~ of valve .......................................X1021 X1022 X1023 X1024 X1025 – of final controlling elements ........................– Optical type ......................................................IEC
8-4.3.2.5 8-4.5.4.7 2-4.3.5.1 6-7.3.3.18 2-6.1.10 2-6.1.12 3-4.1.7 5-4.5.13 2-5.1.2 2-5.1.5 8-4.3.1.1 8-5.3.1 8-4.5.2.2 8-6.1.3 8-4.5.2.3 8-4.5.2.4 8-6.5.4.4 8-6.5.4.2 8-6.5.4.3 8-6.1.2 8-6.5.4.1 8-4.5.2.5 8-4.5.2.1 7-5.1.4 5-4.3.1.6 7-5.1.3 5-4.3.1.5 7-5.1.11 11-4.1.2 12-4.1.10 11-7.5.2 11-7.3.1 6-7.3.1.26 2-11.1.1 8-6.3.4 7-6.5.14 8-6.3.1 7-6.1.5 2-4.3.2.30 6-6.1.2 6-6.5.11 6-6.5.6 6-6.5.7 6-6.5.8 6-6.5.9 6-6.5.10 6-6.5.12 6-6.5.13 6-6.5.14 6-6.5.15 6-6.5.16 6-6.1.1 6-6.5.1 6-6.5.2 6-6.5.3 6-6.5.4 6-6.5.5 6-6 5-4.3.1.19
23
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause)
Not for Resale
--`,,``,`-`-`,,`,,`,`,,`---
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
OR-function (Logic ~).......................................143 Orifice plate......................................................772 Orifice plate type..............................................772 Oscillating motion ............................................228 Other type (of material)....................................328 Outlet tap .........................................................3101 – in taphole ....................................................3102 – Mixing ~ ......................................................3104 – Mixing ~ in taphole .....................................3105 – Mixing ~ on wall..........................................3106 – on wall ........................................................3103 – Self-closing ~..............................................3107 Output – Compensated ~..........................................128 – for auxiliary power supply ...........................183 – label ............................................................106 – Over-current relay with delayed ~ ..............X113 – Postponed ~ ...............................................129 Over-centre hydraulic pump with adjustable capacity.....................................X2407 Over-centre liquid pump ..................................X2306 Over-current relay............................................X113 – with mechanical indicator without automatic return (manual reset) .................X895 Page printing....................................................150 Painting – Coating, for example, ~ .............................2827 Pair – Blind flange ~..............................................517 – Clamped flange ~ .......................................513 – Flange ~ .....................................................511 – Mechanical gear ~ ......................................2008 Parallel identical branches...............................X601 – Connection with n ~ ....................................601 Partial – Momentary and ~ reversal of motion..........262 – Rectilinear motion with ~ reversal...............X258 Passage detector.............................................X3139 Pedal – Manual actuator in the form of ~.................689 Perforating .......................................................152 Permanent magnet ..........................................326 – separator ....................................................X2629 – type.............................................................326 Pig receiver......................................................2042 Pilot-controlled double non-return valve ..........X2234 Pilot-operated non-return valve – closed by pilot pressure..............................X2232 – opened by pilot pressure against return spring ...............................................X2233 Pilot switch, detector........................................3132 Pilot valve – Directional control valve with ~ ...................X2171 X2172 X2173 X2174 Pipe – Boss with insertion ~ ..................................803 – Four pipelines or conductors in a ~ and five pipelines or conductors in another .......................................................X3003 – Located in a circular duct or ~, for example, conductors or cables...................3054 Pipe break valve – Directional leak-free control valve, two ports, two positions ..............................X2183
2-4.3.2.29 6-7.3.3.13 7-5.1.2 5-4.3.1.4 2-6.1.8 2-10.1.6 15-6.1 15-6.2 15-6.4 15-6.5 15-6.6 15-6.3 15-6.7 2-4.3.2.14 2-4.3.5.3 2-4.3.1.1 2-4.5.13 2-4.3.2.15 10-4.5.7 9-4.5.6 2-4.5.13 5-10.5.3 2-4.3.2.34 13-4.3.27 3-6.1.7 3-6.1.3 3-6.1.1 4-4.1.1 7-4.1.14 3-9.5.1 3-9.1.1 2-7.3.2 2-7.5.13 15-8.5.9 4-5.1.9 2-4.3.2.36 2-10.1.4 12-4.5.29 12-4.3.6 7-5.1.16 8-6.5.4.4 8-6.5.4.2 8-6.5.4.3 15-8.1.2 8-6.5.1.11 8-6.5.1.12 8-6.5.1.13 8-6.5.1.14 5-5.1.3 15-4.5.3 15-4.3.4 8-6.5.1.23
Description
– closing when flow rate is higher than set value .....................................................X2122 Pipe – Insertion ~...................................................802 Pipe interrupter – Flushing valve with ~ .................................3109 Pipe reducer ....................................................516 Pipe unit...........................................................449 Pipeline ............................................................405 – Closed end of ~ ..........................................503 – elements.....................................................– – ends............................................................– – ends of specified design.............................– – Exit or entrance of individual ~ ...................603 – Flexible ~, hose ..........................................X411 X412 X413 – or conductor within a six-pipe duct .............X3002 – with 5 % slope to the left.............................X3010 Pipeline going to a storey – above; direction of flow upwards ................X3004 – above coming from a storey below; direction of flow upwards............................X3008 X3009 – below; direction of flow downwards............X3006 X3007 – Insulated ~..................................................X322 – Jacketed (sleeved) ~ ..................................X409 – Jacketed (sleeved) ~, with thermal insulation ....................................................X410 – of circular shape .........................................445 – of flexible type ............................................444 – of rectangular shape...................................446 – of twisted type ............................................448 – Planned ~ ...................................................412 – Twisted ~ of rectangular shape ..................X406 – with thermal insulation................................X322 – with thermal insulation, heated or cooled by separate circuit...........................X408 Pipelines – Four pipelines forming a unit ......................X421 – Four pipelines, two of them forming a unit...........................................................X421 – Four pipelines, two of them of flexible type.................................................X413 – Group of ~ ..................................................406 – Group of planned ~ ....................................413 – Joint of ~.....................................................501 – Three pipelines in single-line representation ............................................X431 X432 – Twisting of ~ ...............................................450 – Two ~ (inlet and outlet) connected to a heat exchanger or heating radiator .........X349 Pipelines and ducts, Installation of ~ ...............– Piston type.......................................................2127 Pitot tube type..................................................778 Planing.............................................................2817 Planned – Group of ~ pipelines, ducts.........................413 – pipeline, duct ..............................................412 Plant.................................................................101 Plants...............................................................– Plate for separating..........................................2607 Plug..................................................................577 Plug type..........................................................2123 Plunger ............................................................711 Plunger type.....................................................2127
24
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause) 8-4.5.3.2 5-5.1.2 15-6.9 3-6.1.6 3-4.3.14 3-4.1.5 3-5.1.3 7-5 3-5 3-6 3-9.1.3 3-4.5.11 3-4.5.12 3-4.5.13 15-4.5.2 15-4.5.10 15-4.5.4 15-4.5.8 15-4.5.9 15-4.5.6 15-4.5.7 2-10.5.2 3-4.5.9 3-4.5.10 3-4.3.10 3-4.3.8 3-4.3.11 3-4.3.8 3-4.1.13 3-4.5.6 3-4.5.7 3-4.5.8 3-4.5.14 3-4.5.14 3-4.5.13 3-4.1.6 3-4.1.9 3-5.1.1 3-4.5.16 3-4.5.17 3-4.3.15 2-11.5.6 15-4 8-4.3.2.7 5-4.3.1.10 13-4.3.17 3-4.1.9 3-4.1.8 2-4.1.1 2-4 12-4.1.8 3-8.1.9 8-4.3.2.3 4-6.1.1 7-4.1.1 8-4.3.2.7
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
Pneumatic actuator – Double-acting ~ ......................................... 720 – Double-acting ~ with different active areas.......................................................... 722 – Single-acting ~........................................... 718 Pneumatic cylinder – Double-acting ~ ......................................... 2448 – Double-acting ~ with double ended piston rod ................................................... X2443 – Double-acting ~ of telescopic type............. 2451 – Single-acting ~ of extension type............... 2445 – Single-acting ~ of retraction type ............... 2447 – Single-acting ~ of telescopic type .............. 2449 Pneumatic motor............................................. 2406 – Actuating device, the main element of which is ~............................................... X742 – Actuator in the form of ~ ............................ X712 – Rotodynamic ~........................................... X2424 – Semi-rotary ~ ............................................. 2416 – with alternative directions of flow ............... 2408 Pneumatic power – Actuating device operated by ~ stored inside the actuator ..................................... X747 Pneumatic power source: See Working direction of pneumatic power Pneumatic pump............................................. 2402 – with alternative directions of flow ............... 2404 See also Gas pump Pneumatic pump/motor................................... 2410 – with alternative directions .......................... 2414 – with one direction....................................... 2412 Pneumatic semi-rotary motor.......................... 2416 Pneumatic type ............................................... 433 Pneumatic-air lubricator .................................. X2674 Pneumatic-hydraulic converter – Continuous ~ ............................................. 2435 – Linear ~...................................................... 2431 Pneumatic-hydraulic pressure intensifier – Continuous ~ ............................................. 2436 – Linear ~...................................................... 2432 Pneumatically operated directional control valve with spring return.............................. X2162 Point of measurement..................................... 1011 – – in pipeline................................................... X1012 – inside pressure vessel ............................... X1011 Poles – Located on ~, for example, pipeline, cable, or power line.................................... 3053 Polishing – Surface treatment by removal of material, for example, by grinding, honing, ~, or sanding ................................. 2824 Pond................................................................ 3206 – Sewage after-treatment ~ .......................... X3213 Port ................................................................. 561 Ports................................................................ – Position ........................................................... 1057 – Electromechanical ~ indicator.................... 865 – Indication of ~ without detention ................ 658 – measuring transducer of differential transformer type......................................... X768 – Transitory ~................................................ 2176 Positions – Indication of ~ of controlled element.......... 701 702 703 704
4-6.1.12 4-6.1.8 10-6.1.6 10-6.5.3 10-6.1.10 10-6.1.2 10-6.1.4 10-6.1.8 10-4.1.6 4-7.5.2 4-6.5.2 10-4.5.24 10-4.1.16 10-4.1.8 4-7.5.7 10-4.1.2 10-4.1.4 10-4.1.10 10-4.1.14 10-4.1.12 10-4.1.16 3-4.3.3 12-6.5.4 10-5.1.2 10-5.1.1 10-5.1.4 10-5.1.3 8-6.5.1.2 6-5.1.1 6-5 6-5.5.2 6-5.5.1 15-4.3.3
13-4.3.24 15-0.3.15 15-0.5.13 3-8.1.1 3-8 6-7.3.1.7 5-10.1.3 4-4.1.14
4-5.3.1 4-5.3.2 4-5.3.3 4-5.3.4
RegisLocation tration (Partnumber subclause)
– Infinite number of intermediate ~ of valve ...........................................................2175 Positive displacement type ..............................2321
4-6.1.10
5-4.5.18 8-6.3.6
Description
– Hydraulic motor of ~ ...................................X2413 – Hydraulic pump of ~....................................X2401 X2402 X2410 X2411 – Liquid pump of ~.........................................X2301 Positive-going – pulse ...........................................................229 – step.............................................................231 Postponed action – Electromechanical counter with ~...............X874 Postponed output.............................................129 Power...............................................................1060 – indication.....................................................X1049 Power source: See Working direction of hydraulic power, pneumatic power Power supply – Input or output for auxiliary ~ ......................183 Pre-heater – of regenerative type....................................2518 Pre-set adjustability..........................................203
– Resistor with ~ ............................................X201 Press filter ........................................................X2611 Pressing – Material forming by ~ ..................................2803 Pressure...........................................................1066 – and temperature compensated flow control valve................................................X2216 – compensated flow control valve .................X2214 X2215 – Continuous pneumatic-hydraulic ~ intensifier ....................................................2436 – Linear, pneumatic-hydraulic ~ intensifier ....................................................2432 – measuring transducer.................................X758 – pilot switch ..................................................X716 – testing facility by direct connection to the process flow..........................................X1052 – transmitting .................................................X1051 Pressure changes – Detector for ~ (burglar detector) .................X3141 Pressure higher than the setting value – Detector for ~..............................................X3140 Pressure reducing control valve – of self-operating type ..................................X2133 Pressure reducing valve ..................................X2198 X2199 – Single-stage, hydraulic ~ ............................X2200 – Two-stage ~................................................X2201 Pressure relief valve – Electrohydraulically operated twostage ~........................................................X2196 X2197 – Single-stage ~.............................................X2191 X2192 – Single-stage ~ with external drain ..............X2193 – Two-stage ~ with provision for remote control.........................................................X2194 X2195 Pressure sensor...............................................X756 – of strain gauge type ....................................X757
8-6.3.5 9-4.3.5 10-4.3.8 10-4.5.13 10-4.5.1 10-4.5.2 10-4.5.10 10-4.5.11 9-4.5.1 2-6.1.9 2-6.1.11 5-8.5.4 2-4.3.2.15 6-7.3.1.10 6-7.5.9
2-4.3.5.3 11-5.1.8 2-5.1.3 8-4.3.1.4 8-5.3.4 10-4.3.2 2-5.5.1 12-4.5.11 13-4.3.3 6-7.3.1.16 8-6.5.3.6 8-6.5.3.7 8-6.5.3.4 8-6.5.3.5 10-5.1.4 10-5.1.3 5-4.5.8 4-6.5.4 6-7.5.12 6-7.5.11 14-8.5.11 15-8.5.10 8-4.5.4.3 8-6.5.2.8 8-6.5.2.9 8-6.5.2.10 8-6.5.2.11 8-6.5.2.6 8-6.5.2.7 8-6.5.2.1 8-6.5.2.2 8-6.5.2.3 8-6.5.2.4 8-6.5.2.5 5-4.5.6 5-4.5.7
--`,,``,`-`-`,,`,,`,`,,`---
25
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
Pressure vessel ...............................................2062 2063 X2072 – with diaphragm ...........................................X2073 – with external electric heater........................X2070 – with heating or cooling jacket .....................X2069 Primary location – in a central control room .............................1101 – in a local control room or on a local control panel ...............................................1103 Printing.............................................................149 – Page ~ ........................................................150 Process – Impact on ~.................................................1072 Processing (functions): See Information processing Profile – Cam ~.........................................................713 – Cam ~ and roller.........................................X711 Propagation – Alternative directions of ~ (half-duplex)................................................250 – Direction of ~ (simplex)...............................249 – Directions of ~ simultaneously in both directions possible (full-duplex) ..................251 Protection unit for potable water systems........3134 Protective gas discharge tube .........................X321 Proximity effect ................................................121 Public lavatory .................................................X3214 Pulling – Control-switch operated by ~......................X682 – Manual actuator operated by ~...................683 Pulsating flow – Hydraulic pump with ~ ................................X2410 Pulse – Negative-going ~ ........................................230 – Positive-going ~..........................................229 Pulse-shaped force, motion, or flow ................225 Pultruding – Material forming by extruding or ~..............2806 Pulverisation – Size reduction by crushing, breaking, or ~ .2808 Pump – Liquid ~ ......................................................2301 – of adsorption type .......................................2336 – of cryo type .................................................2339 – of diffusion type ..........................................2332 – of diffusion-ejector type ..............................2333 – of ejector type .............................................2331 – of entrapment type......................................2335 – of gas-lift type .............................................2334 – of getter type...............................................2337 – of getter ion type.........................................2338 See also Liquid pump, Hydraulic pump, Gas pump, Pneumatic pump, etc. Pumping station ...............................................X3211 Pumping system ..............................................X101 Pure functional type .........................................431 Purge line.........................................................422 Purification by conversion – Devices for ~ ..............................................–
26
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
7-6.1.2 7-6.1.3 7-6.5.12 7-6.5.13 7-6.5.10 7-6.5.9 6-7.3.4.1 6-7.3.4.3 2-4.3.2.33 2-4.3.2.34
Description
RegisLocation tration (Partnumber subclause)
Purifier – of catalytic type...........................................X2651 – using conversion ........................................2651 Pushing – Control-switch operated by ~......................X681 – Manual actuator operated by ~ ..................682 Pushing and pulling – Control-switch operated by ~......................X683 – Manual actuator operated by ~ ..................684
4-6.1.3 7-4.1.3 4-6.5.1
Quality..............................................................1067 Quantity ...........................................................1076 – Actuator operating when characteristic ~ passes set value.........................................733 – Change of state when characteristic ~ is equal to set value....................................174 – Change of state when characteristic ~ is approximately equal to set value ............175 – Change of state when characteristic ~ passes set value from below......................171
2-7.1.8 6-4.3.3 2-7.1.7 6-4.3.2
– Change of state when characteristic ~ passes upper set value from below or lower set value from above ........................173 – Change of state when characteristic ~ passes set value from above......................172
6-7.3.1.22
2-7.1.9 6-4.3.4 15-8.1.4 2-10.5.1 2-4.3.2.7 15-0.5.14
Quantity level – Transition to higher or lower ~....................132
4-5.5.2 4-5.1.3
Quick-acting valve ...........................................X2004 – closing by spring actuator when temperature is higher than 125 °C ............X2123 Quick-release coupling ....................................X563 Quick-release coupling element – fitting into another coupling element of the same type.........................................565 – fitting into another coupling element of the same type and with automatic closing ........................................................568 – of female type.............................................564 – of female type with automatic closing.........567 – of male type................................................563 – of male type with automatic closing............566 Quick-release couplings ..................................–
10-4.5.10 2-6.1.10 2-6.1.9 2-6.1.5 9-4.3.4 10-4.3.6 13-4.3.6 13-4.3.8 15-10.3.7 9-5.1.6 9-5.1.9 9-5.1.2 9-5.1.3 9-5.1.1 9-5.1.5 9-5.1.4 9-5.1.7 9-5.1.8 15-0.5.11 2-4.5.1 3-4.3.1 6-4.3.1 3-4.1.10 12-5
– Transition to higher ~..................................130 – Transition to lower ~ ...................................131
Radiation..........................................................– Radiation..........................................................1068 – Sensor for ionizing ~...................................X764 – Sensor for non-ionizing ~ ...........................X763 Radioactive type ..............................................IEC Railway tanker or trailer tanker ........................3874 Railway track ...................................................3852 Railway turntable serving four railway tracks..........................................................X3852 Railway wagon – Covered ~ or covered trailer.......................3872 – or trailer for non-solid material....................3873 – tip, platform tip............................................3855 – tip, platform tip at the end of a railway track adjacent to a bunker ..........................X3853 Rate of change – Time ~ ........................................................1061 Ratio ................................................................1056 Reaction vessel with spray nozzles.................X2635
12-5.5.1 12-5.1.1 4-5.5.1 4-5.1.2 4-5.5.3 4-5.1.4 6-7.3.1.17 6-7.3.1.26 4-6.1.19 2-4.3.4.4 2-4.3.4.5 2-4.3.4.1 8-4.3.1.5 2-4.3.4.3 2-4.3.4.2 8-4.3.1.6 2-4.3.2.18 11-8.3.3 2-4.3.2.16 11-8.3.1 2-4.3.2.17 11-8.3.2 7-4.5.4 8-4.5.3.3 3-8.5.1 3-8.1.4 3-8.1.7 3-8.1.3 3-8.1.6 3-8.1.2 3-8.1.5 3-8 2-8 6-7.3.1.18 5-4.5.14 5-4.5.13 5-4.3.1.18 14-7.1.14. 14-6.1.2 14-6.5.2 14-7.1.12 14-7.1.13 14-6.1.5 14-6.5.3 6-7.3.1.11 6-7.3.1.6 12-4.5.35
--`,,``,`-`-`,,`,,`,`,,`---
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
--`,,``,`-`-`,,`,,`,`,,`---
Reaming.......................................................... 2816 Receiver.......................................................... 794 Receiving – Transmitting and ~ ultrasonic type............. IEC Receiving ultrasonic type ................................ IEC Reception........................................................ 253 Reciprocating motion ...................................... X252 Reciprocating or rotary pistons – Engines with ~ ........................................... – Reciprocating steam engine ........................... 2581 Recording........................................................ 149 1068 – measuring instrument ................................ 833 – of flow rate with summation of volume....... X1056 – temperature meter ..................................... X851 Rectangular shape.......................................... 446 – Twisted pipeline with ~............................... X406 Rectilinear motion – with alternative directions and intermediate dwell........................................................... X256 – with dwell at return point ............................ X257 – with intermediate dwell .............................. X255 – with intermediate stop................................ X254 – with partial reversal at intermediate position ...................................................... X258 Reduced bore ................................................. 2130 Refrigeration coolant generating plant – Heat-pump ~.............................................. X3206 Refrigerator ..................................................... 2551 X2552 – Device serving as heat pump or ~ ............. X2553 Refrigerators ................................................... – Regenerative pre-heater ................................. 2518 Registering...................................................... 149 1068 – Flow rate ~ of ratio between two flow rates ................................................... X1053 – Indicating and transmitting of level, ~, and alarming .............................................. X1065 – Temperature ~ by scanning....................... X1055 – Voltage ~ ................................................... X1050 Release valve – Self-operating ~ ......................................... 2181 Relief valve – Electrohydraulically operated twostage pressure ~........................................ X2196 X2197 – Single-stage pressure ~............................. X2191 X2192 – Single-stage pressure ~ with external drain........................................................... X2193 – Spring-loaded globe type ~........................ X2135 – Two-stage pressure ~ with provision for remote control....................................... X2194 X2195 Remote control – Manual, ~ of control valve with indication of set value ................................................ X1103 – Manual, ~ of valve with infinite number of stable positions and indication of valve position ............................................. X1102 – Manual, ~ of valve with automatic return to closed position............................. X1101 Removable handle – Actuator with ~........................................... 686 Removal of material – Surface treatment by, ~ for example, by grinding, honing, polishing, or sanding ...... 2824
13-4.3.16 5-4.3.2.4 5-4.3.1.17 5-4.3.1.16 2-7.1.11 2-7.5.7 11-10 11-10.1.1 2-4.3.2.33 6-7.3.1.18 5-7.1.3 6-7.5.16 5-7.5.4 3-4.3.11 3-4.5.6 2-7.5.11 2-7.5.12 2-7.5.10 2-7.5.9 2-7.5.13 8-4.3.2.10 15-10.5.6 11-8.1.1 11-8.5.2 11-8.5.3 11-8 11-5.1.8 2-4.3.2.33 6-7.3.1.18 6-7.5.13 6-7.5.25 6-7.5.15 6-7.5.10 8-8.1.1 8-6.5.2.6 8-6.5.2.7 8-6.5.2.1 8-6.5.2.2 8-6.5.2.3 8-4.5.4.5 8-6.5.2.4 8-6.5.2.5 6-10.3 6-10.2 6-10.1 4-5.1.6 13-4.3.24
Description
Reset – Electromechanical counter with manual ~ to 0..............................................X875 Resistor – adjustable in five steps ...............................X202 – with continuous adjustability .......................X203 – with electric-motor-operated adjustability.................................................X205 – with manual adjustability.............................X204 – with non-linear inherent variability ..............X206 – with pre-set adjustability .............................X201 Resolving .........................................................794 Restricted access – Device for ~ to actuator ..............................692 – to actuator of directional control valve ........X2170 Restriction with pre-set adjustability.................X2031 Restrictor..........................................................2031 Restrictor valve ................................................X2141 Restrictor (valve) – Adjustable ~................................................X2211 X2212 – with adjustable flow in one direction and restricted flow in the other....................X2213 Return – Automatic ~ device .....................................654 Reversal – Momentary and partial ~ of motion.............262 – Rectilinear motion with partial ~ at intermediate position ..................................X258 Reverse............................................................163 Reverse function – component..................................................X104 – Device for ~ ................................................X905 Reversible – conveyor .....................................................X3802 – hydraulic motor ...........................................X2418 X2420 – hydraulic pump ...........................................X2408 – liquid pump .................................................X2307 Ridged shape...................................................447 Riveting – Joining, for example, by ~, glueing, welding, brazing or soldering......................2823 Robot – Materials handling ~ ...................................3843 Robots, material handling ~ .............................– Roll filter ...........................................................X2608 Roller................................................................712 – Cam profile and ~ .......................................X711 Roller type........................................................3824 Rolling – Material forming by ~ ..................................2805 Ropeway type, overhead type .........................3825 Rotatable stator type........................................791 Rotary mixer.....................................................X2671 X2672 Rotary mixing element .....................................2672 Rotary type.......................................................2405 Rotary vane feeder – Conveyor with ~..........................................X3812 X3813 Rotation – Electric motor and pump, motor rotating anti-clockwise, pump clockwise..................X250 X251
5-8.5.5 2-5.5.2 2-5.5.3 2-5.5.5 2-5.5.4 2-5.5.6 2-5.5.1 5-4.3.2.4 4-5.1.12 8-6.5.1.10 7-5.5.1 7-5.1.1 8-4.5.5.1 8-6.5.3.1 8-6.5.3.2 8-6.5.3.3 4-4.1.9 6-6.3.4 2-7.3.2 2-7.5.13 2-4.3.3.3 6-7.3.3.17 2-4.5.4 5-12.5.5 14-4.5.2 10-4.5.18 10-4.5.20 10-4.5.8 9-4.5.7 3-4.3.12 13-4.3.23 14-5.1.3 14-5 12-4.5.8 4-6.1.2 7-4.1.2 4-6.5.1 14-4.3.9 13-4.3.5 14-4.3.10 5-4.3.2.1 12-6.5.1 12-6.5.2 12-6.1.2 5-4.3.1.11 14-4.5.12 14-4.5.13 2-7.5.5 2-7.5.6
27
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause)
Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
Rotodynamic type ............................................2322 – Hydraulic motor of ~ ...................................X2414 X2403 – Liquid pump of ~.........................................X2302 – Pneumatic motor of ~ .................................X2424 RS-bistable element ........................................X112 Rupturing disc..................................................2035 Safety – acting ..........................................................1076 – function .......................................................2112
--`,,``,`-`-`,,`,,`,`,,`---
– Manual actuator with special shape for ~ purpose ..............................................691 Safety valve – Globe type spring-loaded ~ ........................X2124 – opening when the pressure p is higher than the set value ............................X2121 – Spring-loaded ~ ..........................................X2002 – Spring-loaded ~ detained open after operation.....................................................X655 – Weight-loaded ~ .........................................X2001 Salinity meter ...................................................X846 Salt 0.3.14 Sanding – Surface treatment by removal of material, for example, by grinding, honing, polishing, or ~ ................................2824 Saw-tooth shaped force, motion, or flow .........227 Sawing – Dividing by ~ ..............................................2811 Scanning..........................................................1060 – Temperature registering by ~ and alarm ..........................................................X1055 Scraper ............................................................2605 Scraper flights – Belt type with ~ ..........................................3822 Screen .............................................................2602 X2601 X2602 – Vibrating ~ ..................................................X2605 – with rotating drum .......................................X2603 – with rotating drum and scraper...................X2604 Screw conveyor – Compressing ~ ..........................................X3811 Screw feeder with feeding funnel.....................X3809 X3810 Screw type .......................................................3830 Screwed joint ...................................................514 Scrubber – Bath ~ .........................................................X2622 – Spray ~ .......................................................X2621 Seal for penetration of construction – for example, a wall; sealed wall duct .........3002 – partitioning a space with different air pressure......................................................3003 Sealing, for example, by caulking ....................2828 Seat of non-return valve ..................................2162 Selection of – highest value ..............................................138 – lowest value................................................139 – the lowest flow rate signal ..........................X1070 Self-closing outlet tap.......................................3107 Self-operating – back-pressure control valve........................X2132
9-4.3.6 10-4.3.9 10-4.5.14 10-4.5.3 9-4.5.2 10-4.5.24 2-4.5.12 7-5.1.9 6-7.3.1.26 8-4.3.1.2 8-5.3.2 4-5.1.11 8-4.5.3.4 8-4.5.3.1 7-4.5.2 4-4.5.5 7-4.5.1 5-7.5.3 3205 15-
13-4.3.24 2-6.1.7 13-4.3.11 6-7.3.1.10 6-7.5.15 12-4.1.6 14-4.3.7 12-4.1.3 12-4.5.1 12-4.5.2 12-4.5.5 12-4.5.3 12-4.5.4 14-4.5.11 14-4.5.9 14-4.5.10 14-4.3.12 3-6.1.4 12-4.5.22 12-4.5.21 15-4.1.2 15-4.1.3 13-4.3.28 8-6.1.2 2-4.3.2.24 6-7.3.3.9 2-4.3.2.25 6-7.3.3.10 6-7.5.30 15-6.7 8-4.5.4.2
Description
– pressure reducing control valve .................X2133 – release valve ..............................................2181 Semi-rotary – hydraulic motor...........................................2415 X2412 – pneumatic motor.........................................2416 Semiconductor – Temperature measuring transducer with sensor of ~ type ..................................X762 – type.............................................................IEC Sensing............................................................1055 Sensor .............................................................751 752 – Flow rate ~..................................................X759 – for ionizing radiation ...................................X764 – for non-ionizing radiation ............................X763 – Heat (temperature) ~ ..................................X3131 – Level ~........................................................X751 – Pressure ~..................................................X756 – Pressure ~, strain gauge type ....................X757 – Temperature ~ in boss with well.................X801 – Temperature ~ in insertion pipe..................X802 – Temperature ~, thermocouple type ............X761 Sensors ...........................................................– Separating – Device for ~ ................................................2601 – Devices for ~ ..............................................– – Plate for ~ ...................................................2607 Separator – Cyclone ~ ...................................................X2618 – Disc and plate (knife) ~...............................X2615 – Electromagnetic ~.......................................X2628 – Electrostatic ~.............................................X2627 – Permanent-magnet ~ .................................X2629 – Settling ~ ....................................................X2616 – Settling ~ with space for reject and with reject outlet..........................................X2617 – Thermal ~ using direct-heating source.......X2632 – Thermal ~ using electrical heating..............X2631 – Thermal ~ using heating or cooling coil ..............................................................X2630 Sequence – Three connections with changed ~ ............X605 – Three connections with reversed ~ ............X604 Servo-control valve – Directional ~ with negative overlapping.................................................X2176 – Directional ~ with positive overlapping.................................................X2175 Set value – Actuator operating when characteristic quantity passes ~ .......................................733 – Change of state when characteristic quantity passes ~ from above ....................172 – Change of state when characteristic quantity passes ~ from below.....................171 – Change of state when characteristic quantity is approximately equal to ~ ...........175 – Change of state when characteristic quantity is equal to ~ ..................................174 – Characteristic quantity, change of state when characteristic quantity passes upper set value from below or lower ~ from above.................................173 Setting of set value – Manual ~.....................................................X1047 Settling separator.............................................X2616
28
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause) 8-4.5.4.3 8-8.1.1 10-4.1.15 10-4.5.12 10-4.1.16 5-4.5.12 5-4.3.1.20 6-7.3.1.5 5-4.1.1 5-4.1.2 5-4.5.9 5-4.5.14 5-4.5.13 15-8.5.1 5-4.5.1 5-4.5.6 5-4.5.7 5-5.5.1 5-5.5.2 5-4.5.11 5-4 12-4.1.1 12-4 12-4.1.8 12-4.5.18 12-4.5.15 12-4.5.28 12-4.5.27 12-4.5.29 12-4.5.16 12-4.5.17 12-4.5.32 12-4.5.31 12-4.5.30 3-9.5.5 3-9.5.4 8-6.5.1.16 8-6.5.1.15 4-6.1.19 2-4.3.4.2 8-4.3.1.6 2-4.3.4.1 8-4.3.1.5 2-4.3.4.5 2-4.3.4.4
2-4.3.4.3 6-7.5.7 12-4.5.16
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
--`,,``,`-`-`,,`,,`,`,,`---
– with space for the reject and with reject outlet ................................................ X2617 Sewage – after-treatment pond .................................. X3213 – treatment plant........................................... X3212 – water .......................................................... 3204 Shaft................................................................ 402 403 – Electrically insulating ~ .............................. 404 – Flexible, electrically insulating ~ ................ X404 Shape – Circular ~ ................................................... 445 – Rectangular ~ ............................................ 446 – Ridged ~ .................................................... 447 Shearing – Dividing by ~ ............................................. 2812 Shelf store....................................................... 2066 Ship – Cargo ~...................................................... 3881 Ships ............................................................... – Shower – Hand-held ~ ............................................. 3108 Shuttle valve – Directional control valve, three ports, three positions ........................................... X2181 X2182 – Directional control valve, three ports, two positions .............................................. X2179 X2180 Sieve ............................................................... X2601 X2602 – Vibrating ~.................................................. X2605 Signal – Analogue ~ ................................................ 234 ................................................................... – Binary ~ ..................................................... 236 ................................................................... – Digital ~...................................................... 235 Signal converter .............................................. 753 – for electric power ....................................... X114 – or measuring transducer............................ X765 – without connection between input and output circuits...................................... 755 756 Signal converters ............................................ – Signal flow – with alternative directions (half-duplex)...... 250 – with one direction (simplex) ....................... 249 – with simultaneous ~ in both directions possible (full-duplex).................................. 251 Signal processing – Devices for analogue ~.............................. – Signalling device – Acoustic ~ .................................................. 866 Signalling devices ........................................... – Silencer ........................................................... 2033 Simplex – Direction of propagation, energy, or signal flow .................................................. 249 Simplifications ................................................. – – Additional ~................................................ – Single-acting diaphragm actuator ................... 725
12-4.5.17 15-0.5.13 15-0.5.12 15-0.3.13 3-4.1.2 3-4.1.3 3-4.1.4 3-4.5.4 3-4.3.10 3-4.3.11 3-4.3.12 13-4.3.12 7-6.1.6 14-7.1.16 14-7 15-6.8 8-6.5.1.21 8-6.5.1.22 8-6.5.1.19 8-6.5.1.20 12-4.5.1 12-4.5.2 12-4.5.5 2-6.1.14 6-4.3.5 2-6.1.16 6-4.3.7 2-6.1.15 6-4.3.6 5-4.1.3 2-4.5.14 5-4.5.15 5-4.1.5 5-4.1.6 5-4 2-7.1.8 6-4.3.3 2-7.1.7 6-4.3.2 2-7.1.9 6-4.3.4 5-12 5-10.1.4 5-10 7-5.1.7 2-7.1.7 6-4.3.2 2-11 3-9 4-6.1.15
Description
Single-acting fluid cylinder – Actuating device with the main element in the form of single-acting fluid cylinder.....X741 – Actuator in the form of a ~ ..........................723 Single-acting hydraulic actuator.......................717 – of extension type ........................................2441 – of retraction type .........................................2446 – of telescopic type........................................2443 – with automatic return, spring.......................X2442 – with drain ....................................................X2441 Single-acting pneumatic actuator.....................718 – of extension type ........................................2445 – of retraction type .........................................2447 – of telescopic type........................................2449 Single-line representation ................................– – Transition between multi-line and ~............602 Single-stage pressure reducing valve..............X2200 Single-stage pressure relief valve....................X2191 X2192 Single-stage pressure relief valve with external drain ..............................................X2193 Sintering – Size enlarging by ~, agglomeration, coagulation, or flocculation .........................2809 Sinusoidal – Burst of ~ flow.............................................226 Sinusoidal flow – Hydraulic pump with ~ ................................X2411 Sinusoidal force, motion, or flow......................224 Siphon, anti-siphon trap ...................................2038 2038 Size reduction by crushing, breaking, or pulverisation ...............................................2808 Sleeve – Expansion ~................................................532 – for penetration of construction, for example, a wall; wall duct ..........................3001 Slide – Spiral gravity ~............................................X3808 – Straight gravity ~.........................................X3807 Slope................................................................3061 – Pipeline with 5 % ~ to the left .....................X3010 Smoke..............................................................3143 – detector.......................................................X3136 Socket..............................................................576 Soldered joint ...................................................515 Soldering – Joining, for example, by riveting, glueing, welding, brazing or ~ ....................2823 Solenoid – -operated brake applied at no-voltage........X652 – -operated clutch, disengaged at no-voltage...................................................X651 – -operated valve...........................................X2103 Sound ..............................................................3141 – (acoustic) alarm ..........................................3068 – detector.......................................................X3133 – (letter symbol).............................................3064 Spectacle blind – in closed position ........................................2044 – in open position ..........................................2045 Speed ..............................................................1069 Spiral gravity – slide ............................................................X3808 – (sliding) type ...............................................3833
4-7.5.1 4-6.1.13 4-6.1.7 10-6.1.1 10-6.1.3 10-6.1.7 10-6.5.2 10-6.5.1 4-6.1.8 10-6.1.2 10-6.1.4 10-6.1.8 2-11 3-9.1.2 8-6.5.2.10 8-6.5.2.1 8-6.5.2.2 8-6.5.2.3 13-4.3.9 2-6.1.6 10-4.5.11 2-6.1.4 10-4.3.5 7-5.1.12 15-10.3.5 13-4.3.8 3-7.1.2 15-4.1.1 14-4.5.8 14-4.5.7 14-4.3.5 15-4.3.11 15-4.5.10 15-8.3.3 15-8.5.6 3-8.1.8 3-6.1.5 13-4.3.23 4-4.5.2 4-4.5.1 8-4.5.1.3 15-8.3.1 15-4.3.18 15-8.5.3 15-4.3.14 7-5.1.18 7-5.1.19 6-7.3.1.19 14-4.5.8 14-4.3.15
29
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause)
Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
Spray nozzle ....................................................2037 Spray scrubber ................................................X2621 Spring ..............................................................2002 – Single-acting hydraulic cylinder with automatic return by ~..................................X2442 Spring equipped buffer ....................................X2006 Spring-loaded – actuating device..........................................X2005 – Angled, globe type ~ vacuum valve............X2125 – ball type non-return valve ...........................X2115 – globe type relief valve.................................X2135 – non-return valve..........................................X2231 – safety valve.................................................X2002 – safety valve detained open after operation.....................................................X655 Spring operation – Actuating device, spring-operated with manual spring charging.......................X745 – Actuating device, spring-operated with spring charging by electric motor ........X746 Square root extraction of flow rate signal ........X1068 Square-shaped access chamber, inspection well ............................................3086 Stabilizer – Voltage ~ ....................................................X109 Stabilizing ........................................................125 Stack................................................................2041 State: See Change of state Static mixing element.......................................2673 Steam engine – of reciprocating type ...................................2581 Steam generator ..............................................2531 X2535 Steam generators ............................................– Steam trap .......................................................2181 Steam turbine ..................................................2571 – with centre inlet...........................................2572 – with centre inlet and outlet taps ..................X2571 Steam turbines.................................................– Step – Negative-going ~ ........................................232 – Positive-going ~..........................................231 Stepping function .............................................233 Stepping hydraulic motor.................................X2421 Stepwise variability ..........................................211 Sterling motor ..................................................2583 Stirrer ...............................................................X2671 Stop – Intermediate ~ ............................................X254 Storage – Devices for ~ ..............................................– Store – Open ~........................................................2065 – Shelf ~ ........................................................2066 Storey – Going between a ~ above and a ~ below, for example, pipeline, cable, or conductor bundle....................................3060 – Going to a ~ above, for example, pipeline, cable, or conductor bundle...........3058 – Going to a ~ below, for example, pipeline, cable, or conductor bundle...........3059 Stove or water heater of fired type...................X3151 Straight gravity slide.........................................X3807
7-5.1.11 11-4.1.2 12-4.1.10 12-4.5.21 4-4.1.10 7-4.1.8 10-6.5.2 7-4.5.6 7-4.5.5 8-4.5.3.5 8-4.5.2.5 8-4.5.4.5 8-6.5.4.1 7-4.5.2 4-4.5.5 4-7.5.5 4-7.5.6 6-7.5.28 15-5.1.6 2-4.5.9 2-4.3.2.11 7-5.1.15 12-6.1.3 11-10.1.1 11-7.1.1 11-7.5.5 11-7 8-8.1.1 11-9.1.1 11-9.1.2 11-9.5.1 11-9 2-6.1.12 2-6.1.11 2-6.1.13 10-4.3.7 10-4.5.21 2-5.3.1 11-10.1.3 12-6.5.1 2-7.5.9 7-6 7-6.1.5 7-6.1.6
15-4.3.10 15-4.3.8 15-4.3.9 15-9.5.1 14-4.5.7
Description
RegisLocation tration (Partnumber subclause)
Straightener – Flow ~.........................................................2032 Strain gauge type.............................................IEC Strainer ............................................................X2601 X2602 Subtraction function component ......................X102 Subtraction of flow rate signals........................X1067 Summing .........................................................1067 – amplifier......................................................X909 – Device for ~ ................................................X901 – of flow rate signals......................................X1066 – of volume....................................................X1056 Superheater – Boiler with ~................................................X2534 Surface treatment by removal of material, for example, by grinding, honing, polishing, or sanding ..................................2824 Surface treatment without removal of material, for example, by rolling..................2825 Swing-type non-return valve............................X2114 Switching .........................................................1069 – Manual ~.....................................................X1046 – Temperature ~............................................X1063 X1064 Switching device – Three-pole electromechanical ~.................X659 Synchro effect – Measuring transducer utilizing the synchro effect .............................................760 Synchronizing ..................................................141 T-bore in a three- or four-way valve.................2114 T-joint...............................................................X504 X505 X507 X508 – of mechanical links .....................................X501 X502 Tachometer generator .....................................759 – of DC type ..................................................X766 – of optical type .............................................X767 Tank (envelope)...............................................301 Tank (for storing) – Closed ~ for atmospheric pressure ............X2061 – for atmospheric pressure............................2061 – – – –
truck............................................................3870 with conic bottom........................................X2062 with conic roof ............................................X2063 with conic roof and provided with internal heating or cooling coil ....................X2068 – with conic roof and surface of liquid provided with floating balls .........................X2067 – with floating roof .........................................X2065 – with torispheric roof ....................................X2064 Tanker – Railway ~ or trailer ~...................................3874 Tanks (envelopes) ...........................................– Tanks (for storing)............................................– Tap: See Outlet tap Tapping............................................................2819 Technical plants and systems .........................– Telescopic cylinder – Double-acting, hydraulic ~..........................2450 – Double-acting, pneumatic ~ .......................2451 – Single-acting, hydraulic ~ ...........................2443 – Single-acting, pneumatic ~.........................2449
7-5.1.6 5-4.3.1.12 12-4.5.1 12-4.5.2 2-4.5.2 6-7.5.27 6-7.3.1.17 5-12.5.9 5-12.5.1 6-7.5.26 6-7.5.16 11-7.5.4 13-4.3.24 13-4.3.25 8-4.5.2.4 6-7.3.1.19 6-7.5.6 6-7.5.23 6-7.5.24 4-4.5.9 5-4.1.9 2-4.3.2.27 8-4.3.1.8 3-5.5.4 3-5.5.5 3-5.5.7 3-5.5.8 3-5.5.1 3-5.5.2 5-4.1.8 5-4.5.16 5-4.5.17 2-9.1.1 11-4.1.1 12-4.1.2 7-6.5.1 7-6.1.1 15-10.3.6 14-7.1.10 7-6.5.2 7-6.5.3 7-6.5.8 7-6.5.7 7-6.5.5 7-6.5.4 14-7.1.14. 2-9 7-6 13-4.3.19 15-10 10-6.1.9 10-6.1.10 10-6.1.7 10-6.1.8
--`,,``,`-`-`,,`,,`,`,,`---
30
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
--`,,``,`-`-`,,`,,`,`,,`---
Television transmission and monitoring.......... X1060 Temperature ................................................... 1070 – and flow rate cascade control .................... X1105 – detector...................................................... X3132 – indication.................................................... X1059 – measuring transducer with built-in sensor of semiconductor type.................... X762 – measuring transducer with output contact ....................................................... X770 – meter with output contact........................... X843 – meter with dial in °C................................... X842 – pilot switch ................................................. X717 – Pressure and ~ compensated flow control valve............................................... X2216 X2217 – Recording ~ meter ..................................... X851 – registering by scanning and alarm............. X1055 – sensor........................................................ X3131 – sensor in an insertion pipe......................... X802 – sensor, thermocouple type ........................ X761 – switching .................................................... X1063 X1064 Tempering – Heat treatment, for example, annealing or ~ ............................................................ 2807 Test point ........................................................ 154 – Connection of ~ ......................................... 1066 Testing – Pressure ~ facility ...................................... X1052 Thermal – insulation.................................................... X322 X408 X410 – separator using direct-heating source ....... X2632 – separator using electrical heating .............. X2631 – separator using heating or cooling coil ...... X2630 Thermal power – Combined electric ~ and hot water generating plant ......................................... X3204 Thermocouple ................................................. 757 – Temperature sensor, ~ type ...................... X761 Thermometer .................................................. 831 Threading........................................................ 2820 Three identical items....................................... 343 Three-pole electromechanical switching device ........................................................ X659 Three-way – damper with diaphragm actuator ............... X2152 – valve .......................................................... 2103 – valve with diaphragm actuator................... X2102 – valve with fluid cylinder actuator ................ X2107 Threshold ........................................................ 137 Time ................................................................ 1061 Time rate of change ........................................ 1061 Time-sharing – information processing function ................. 1042 Tip – Railway wagon ~, platform ~ ..................... 3855 – Railway wagon ~, platform ~ at the end of a railway track adjacent to a bunker ...... X3853 Torque converter – Hydraulic, rotary ~...................................... 2434 – Hydraulic, rotary, adjustable ~ ................... X2431 Torque measurement...................................... 795 Touch effect .................................................... 122 – Actuating device, operating with ~............. X744
6-7.5.20 6-7.3.1.20 6-10.5 15-8.5.2 6-7.5.19 5-4.5.12 5-4.5.20 5-7.5.2 5-7.5.1 4-6.5.5 8-6.5.3.6 8-6.5.3.7 5-7.5.4 6-7.5.15 15-8.5.1 5-5.5.2 5-4.5.11 6-7.5.23 6-7.5.24 13-4.3.7 2-4.3.2.38 6-7.3.1.16 6-7.5.12 3-4.5.7 3-4.5.8 3-4.5.10 12-4.5.32 12-4.5.31 12-4.5.30 15-10.5.4 5-4.1.7 5-4.5.11 5-7.1.1 13-4.3.20 2-11.1.3 4-4.5.9 8-5.5.2 8-4.1.3 8-4.5.1.2 8-4.5.1.7 2-4.3.2.23 5-12.3.5 6-7.3.3.8 6-7.3.1.11 6-7.3.1.11 6-7.1.2 14-6.1.5 14-6.5.3 10-5.1.5 10-5.5.1 5-4.3.2.5 2-4.3.2.8 4-7.5.4
Description
Tracer...............................................................711 Track – Railway ~ ....................................................3852 – turntable......................................................3854 Tracks and associated devices........................– Trailer – Covered railway wagon or covered ~ ........3872 Transducer – Measuring ~: See Measuring transducer Transition – to a higher or lower quantity level ...............132 – to a higher quantity level.............................130 – to a lower quantity level ..............................131 Transition between multi-line and single-line representation............................602 Transitory position............................................2176 Transmission....................................................252 – Television ~ and monitoring........................X1060 Transmitter.......................................................796 Transmitters.....................................................– Transmitting .....................................................1070 – and receiving, ultrasonic type .....................IEC – of difference pressure.................................X1054 – of level ........................................................X1065 – of pressure..................................................X1051 – of ratio between two flow rates ...................X1053 – of temperature ............................................X1059 – of ultrasonic type.........................................IEC Trap – Anti-siphon ~...............................................2038 – Steam ~ ......................................................2181 Traverser, traversing platform..........................3853 – with one railway track on one side and two railway tracks on the other ...................X3851 Tray – Located on a ~, for example, pipelines, conductors, or cables; endpoints indicated. ....................................................3056 – Located on a ~, for example, pipelines, conductors, or cables; continuous ..............3057 Tray column .....................................................X2625 – with passage for gas...................................X2626 Treadle.............................................................690 Trip-free mechanism........................................665 Truck – Container ~ .................................................3864 – Driverless, automatic~, including remote controlled........................................3863 – Fork lift ~ ....................................................3862 – Industrial ~ .................................................3861 – Tank ~.........................................................3870 Trucks ..............................................................– Turbine: See Steam turbine, Gas turbine, Water turbine, Wind turbine, etc. Turbine type .....................................................2405 Turbo-fan jet motor ..........................................2575 Turbo-molecular type .......................................2323 Turn table.........................................................3808 – Railway ~ serving four railway tracks .........X3852 – Two conveyors of roller type interlinked by a ~..........................................................X3815 Turning.............................................................2822 – Actuator operated by ~ ...............................685
4-6.1.1 7-4.1.1 14-6.1.2 14-6.1.4 14-6 14-7.1.12
2-4.3.2.18 11-8.3.3 2-4.3.2.16 11-8.3.1 15-10.3.1 2-4.3.2.17 11-8.3.2 15-10.3.2 3-9.1.2 8-6.3.6 2-7.1.10 6-7.5.20 5-4.3.2.6 5-4 6-7.3.1.20 5-4.3.1.17 6-7.5.14 6-7.5.25 6-7.5.11 6-7.5.13 6-7.5.19 5-4.3.1.15 7-5.1.12 8-8.1.1 14-6.1.3 14-6.5.1
15-4.3.6 15-4.3.7 12-4.5.25 12-4.5.26 4-5.1.10 4-4.1.21 14-7.1.4 14-7.1.3 14-7.1.2 14-7.1.1 14-7.1.10 14-7 5-4.3.1.11 11-9.1.5 9-4.3.7 14-4.1.4 14-6.5.2 14-4.5.15 13-4.3.22 4-5.1.5
31
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
RegisLocation tration (Partnumber subclause)
Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
– Control-switch operated by ~......................X687 – Control-switch operated by ~, automatic return..........................................X686 Twisted – pipeline, or duct ..........................................448 – rectangular pipeline or duct ........................X406 Twisting of pipelines ........................................450 Two identical items ..........................................342 Two or more identical items.............................344 345 Two-stage pressure reducing valve.................X2201 Two-stage pressure relief valve with provision for remote control ........................X2194 X2195 Two-way valve with diaphragm actuator..........X2101 Two-way valve with solenoid actuator .............X2103 Two- or three-way damper...............................2151 Two-way valve .................................................2101 – Angled ~ .....................................................2102 – with electric motor actuator.........................X2104 Ultrasonic type – Receiving ~.................................................IEC – Transmitting and receiving ~ ......................IEC – Transmitting ~.............................................IEC Unclassified variable or function ......................1074 Underground – Located, ~ for example, pipeline, cable, or joint .............................................3051 – hydrant........................................................3121 – joint of pipeline or cable..............................X3001 Underwater – Located ~, for example, pipeline or cable ...........................................................3052 Uni-directional belt conveyor driven by electric motor..............................................X3801 Uni-flow – hydraulic pump ...........................................X2409 – liquid pump .................................................X2308 Unidirectional information bus type..................442 User's choice ...................................................1064 1065 1072 1075 Vacuum............................................................1066 Vacuum cleaner...............................................X2613 Vacuum pump .................................................2302 See also Entrainment pumps, Entrapment pumps Vacuum valve – Angled globe type, spring-loaded ~............X2125 Vacuum vessel ................................................2062 2063 Value – Selection of highest ~ .................................138 – Selection of lowest ~ ..................................139 Valve: See also Control valve, Safety valve, Shut-off valve, Non-return valve, Directional control valve, etc. Valve for fluid power ........................................2161 Valves – for fluid power systems...............................– – with special functions..................................– Van ..................................................................3869
4-5.5.7 4-5.5.6 3-4.3.13 3-4.5.6 3-4.3.15 2-11.1.2 2-11.1.4 2-11.1.5 8-6.5.2.11 8-6.5.2.4 8-6.5.2.5 8-4.5.1.1 8-4.5.1.3 8-5.1.1 8-4.1.1 8-4.1.2 8-4.5.1.4 5-4.3.1.16 5-4.3.1.17 5-4.3.1.15 6-7.3.1.24 15-4.3.1 15-7.1 15-4.5.1 15-4.3.2 14-4.5.1 10-4.5.9 9-4.5.8 3-4.3.6 6-7.3.1.14 6-7.3.1.15 6-7.3.1.22 6-7.3.1.25 6-7.3.1.16 12-4.5.13 9-4.1.2
8-4.5.3.5 7-6.1.2 7-6.1.3 2-4.3.2.24 6-7.3.3.9 2-4.3.2.25 6-7.3.3.10
8-6.1.1 8-6 8-8 14-7.1.9
Description
RegisLocation tration (Partnumber subclause)
Vane feeder – Conveyor with rotary ~ ...............................X3812 X3813 – Conveyor with vibrating rotary ~.................X3814 – rotor ............................................................3807 Variability .........................................................– – Continuous ~ ..............................................212 – Inherent ~ ...................................................204 – Non-linear, inherent ~.................................205 – Resistor with non-linear inherent ~.............X206 – Stepwise ~..................................................211 See also Adjustability Variable area flow type ....................................777 Vehicles ...........................................................– Vent .................................................................2039 Venturi element................................................775 Venturi tube type..............................................775 Very high..........................................................1082 1083 Very low...........................................................1087 1088 Vessel – Boiler feedwater ~ with deaerator...............X2071 – Pressure or vacuum ~ ................................2062 2063 – Pressure ~..................................................X2072 – Pressure ~ with diaphragm ........................X2073 – Pressure ~ with external electric heater .....X2070 – Pressure ~ with heating or cooling jacket ..........................................................X2069 – Reaction ~ with spray nozzles....................X2635 Vibrating screen, sieve ....................................X2605 Vibrating – Conveyor with ~ rotary vane feeder ...........X3814 – (tactile) alarm..............................................3069 – type.............................................................3831 Vibration...........................................................3831 – detector ......................................................X3142 – detector for vertical vibrations.....................X3143 Viewing ............................................................1057 Viewing glass...................................................2034 Voltage – registering...................................................X1050 – stabilizer .....................................................X109 Volume meter based on time integration of flow rate ..................................................X855 Wall hydrant.....................................................3123 Washing machine with spinning ......................X2623 Waste ..............................................................3207 – disposal plant (waste tip)............................X3215 Water heater – Stove or ~ of fired type ...............................X3151 Water heaters, air conditioners........................– Water tower plant.............................................X3210 Water-sprayed cooler ......................................X2504 Water turbine ...................................................X2414 Waterworks......................................................X3207 Weight..............................................................1073 2001 Weight-loaded – non-return valve .........................................X2111 – safety valve ................................................X2001 Welded joint.....................................................515 Welding – Joining, for example, by riveting, glueing, ~, brazing or soldering ..................2823
14-4.5.12 14-4.5.13 14-4.5.14 14-4.1.3 2-5 2-5.3.2 2-5.1.4 2-5.1.5 2-5.5.6 2-5.3.1 5-4.3.1.9 14-7 7-5.1.13 7-5.1.5 5-4.3.1.7 6-7.3.2.2 6-7.3.2.3 6-7.3.2.7 6-7.3.2.8 7-6.5.11 7-6.1.2 7-6.1.3 7-6.5.12 7-6.5.13 7-6.5.10 7-6.5.9 12-4.5.35 12-4.5.5 14-4.5.14 15-4.3.19 14-4.3.13 15-8.3.5 15-8.5.12 15-8.5.13 6-7.3.1.7 7-5.1.8 6-7.5.10 2-4.5.9 5-7.5.5 15-7.3 12-4.5.23 15-0.3.16 15-0.5.15 15-9.5.1 15-9 15-0.5.10 11-4.5.4 10-4.5.14 15-10.5.7 6-7.3.1.23 7-4.1.7 8-4.5.2.1 7-4.5.1 3-6.1.5 13-4.3.23
--`,,``,`-`-`,,`,,`,`,,`---
32
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Description
RegisLocation tration (Partnumber subclause)
Well – Boss with ~ ................................................ 801 Wet rotor ......................................................... X2311 X2425 Wheel.............................................................. 2013 – loader......................................................... 3865 Window foil – Electric~..................................................... 3133 Wind turbine.................................................... X2424 Wire................................................................. 403 – Chain or ~driven type ................................ 3823 – Electrically insulating ~ .............................. 404 Working direction of – hydraulic power.......................................... 243 X246 – pneumatic power ....................................... 244
5-5.1.1 9-4.5.11 10-4.5.25 7-4.1.19 14-7.1.5 15-8.1.3 10-4.5.24 3-4.1.3 14-4.3.8 3-4.1.4 2-7.1.3 2-7.5.3 2-7.1.4
--`,,``,`-`-`,,`,,`,`,,`---
33
© ISOfor2005 – All rights reserved Copyright International Organization Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
Annex B (informative) Index of graphical symbol registration numbers
--`,,``,`-`-`,,`,,`,`,,`---
This registration number index may be used to find a graphical symbol whose registration number is known. RegisLocation tration (Partnumber subclause) 101
2-4.1.1 13-4.1.1 15-9.1.1 15-10.1.1
106 107 111 112 113
2-4.3.1.1 2-4.3.1.2 2-4.3.2.1 2-4.3.2.2 2-4.3.2.3
114
2-4.3.2.4
115 119 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137
2-4.3.2.5 6-7.3.3.1 2-4.3.2.6 2-4.3.2.7 2-4.3.2.8 2-4.3.2.9 6-7.3.3.2 2-4.3.2.10 6-7.3.3.3 2-4.3.2.11 2-4.3.2.12 2-4.3.2.13 2-4.3.2.14 2-4.3.2.15 2-4.3.2.16 11-8.3.1 15-10.3.1 2-4.3.2.17 11-8.3.2 15-10.3.2 2-4.3.2.18 11-8.3.3 2-4.3.2.19 5-12.3.1 6-7.3.3.4 2-4.3.2.20 5-12.3.2 6-7.3.3.5 2-4.3.2.21 5-12.3.3 6-7.3.3.6 2-4.3.2.22 5-12.3.4 6-7.3.3.7 2-4.3.2.23 5-12.3.5 6-7.3.3.8
Description Complex device, functional unit, equipment, plant, function Complex device, functional unit, equipment Complex device, functional unit, plant, function Complex device, functional unit, plant, function Label (Input or output label) Label grouping Conversion Conversion Conversion without connection between input and output circuits Conversion without connection between input and output circuits Amplification
RegisLocation tration (Partnumber subclause)
171
2-4.3.2.24 6-7.3.3.9 2-4.3.2.25 6-7.3.3.10 2-4.3.2.26 6-7.3.3.11 2-4.3.2.27 2-4.3.2.28 6-7.3.3.12 2-4.3.2.29 6-7.3.3.13 2-4.3.2.30 2-4.3.2.31 6-7.3.3.14 13-4.3.29 2-4.3.2.32 2-4.3.2.33 2-4.3.2.34 2-4.3.2.35 2-4.3.2.36 2-4.3.2.37 2-4.3.2.38 2-4.3.3.1 6-7.3.3.15 2-4.3.3.2 6-7.3.3.16 2-4.3.3.3 6-7.3.3.17 2-4.3.4.1
172
8-4.3.1.5 2-4.3.4.2
173
8-4.3.1.6 2-4.3.4.3
Transition to a higher or lower quantity level
174
2-4.3.4.4
High limitation
175
2-4.3.4.5
High limitation
181
Low limitation
182 183
2-4.3.5.1 6-7.3.3.18 2-4.3.5.2 2-4.3.5.3
Magnetic field effect Proximity effect Touch effect Delay Hysteresis Stabilizing Enabling input Compensating input Compensated output Postponed output Transition to a higher quantity level
138 139 140 141 142 143 144 145 148 149 150 151 152 153 154 161 162 163
Transition to a lower quantity level
201 Low limitation Dead band; threshold
34
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
2-5.1.1 8-4.3.1.3 8-5.3.3 9-4.3.1 10-4.3.1 10-5.3.1 14-4.3.1
Description Selection of highest value Selection of lowest value Comparing Synchronizing Logic AND-function Logic OR-function Automatic operation Complex function Complex function, multi-function Indicating Registering; recording, printing Page printing Facsimile Perforating Input by keyboard Test point Dividing Bias Reverse Change of state when the characteristic quantity passes a set value from below Change of state when the characteristic quantity passes a set value from above Change of state when the characteristic quantity passes an upper set value from below or a lower set value from above Change of state when the characteristic quantity is equal to a set value Change of state when the characteristic quantity is approximately equal to a set value Logic negation Logic inversion Input or output for auxiliary power supply Adjustability
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
RegisLocation tration (Partnumber subclause) 202 203
204 205 211 212 221 222 223 224
2-5.1.2 2-5.1.3 8-4.3.1.4 8-5.3.4 10-4.3.2 2-5.1.4 2-5.1.5 2-5.3.1 2-5.3.2 2-6.1.1 9-4.3.2 10-4.3.3 2-6.1.2 9-4.3.3 10-4.3.4 2-6.1.3
241
2-6.1.4 10-4.3.5 2-6.1.5 9-4.3.4 10-4.3.6 2-6.1.6 2-6.1.7 2-6.1.8 2-6.1.9 2-6.1.10 2-6.1.11 2-6.1.12 2-6.1.13 10-4.3.7 2-6.1.14 6-4.3.5 2-6.1.15 6-4.3.6 2-6.1.16 6-4.3.7 2-7.1.1
242
14-4.3.2 15-10.3.3 2-7.1.2
243 244 245
2-7.1.3 2-7.1.4 2-7.1.5
246
14-4.3.3 2-7.1.6
247 249
14-4.3.4 2-7.1.7
250
6-4.3.2 2-7.1.8
251
6-4.3.3 2-7.1.9
225 226 227 228 229 230 231 232 233 234 235 236
252 253 254 255 256 261
6-4.3.4 2-7.1.10 2-7.1.11 2-7.1.2 12-4.3.1 2-7.1.13 12-4.3.2 2-7.1.14 2-7.3.1
RegisLocation tration (Partnumber subclause)
Description Non-linear adjustability Pre-set adjustability
262 263 301
402 403 404
2-7.3.2 2-7.3.3 2-9.1.1 11-4.1.1 12-4.1.2 2-10.1.1 15-10.3.4 2-10.1.2 2-10.1.3 2-10.1.4 12-4.3.6 2-10.1.5 2-10.1.6 2-11.1.1 2-11.1.2 2-11.1.3 2-11.1.4 2-11.1.5 3-4.1.1 6-4.1.1 3-4.1.2 3-4.1.3 3-4.1.4
Inherent variability Non-linear inherent variability Stepwise variability Continuous variability Constant force, motion, or flow
321
405 406 411 412 413 422
3-4.1.5 3-4.1.6 3-4.1.7 3-4.1.8 3-4.1.9 3-4.1.10
Analogue signal
431
Digital signal
432 433 434 435 442 443 444 445 446 447 448 449 450 451 452 501
Transmission Reception Circular motion, unspecified direction
503 511 512 513 514 515 516 517 518 531 532 533 561 563
3-4.3.1 6-4.3.1 3-4.3.2 3-4.3.3 3-4.3.4 3-4.3.5 3-4.3.6 3-4.3.7 3-4.3.8 3-4.3.10 3-4.3.11 3-4.3.12 3-4.3.13 3-4.3.14 3-4.3.15 3-4.3.16 3-4.3.9 3-5.1.1 6-4.1.2 3-5.1.3 3-6.1.1 3-6.1.2 3-6.1.3 3-6.1.4 3-6.1.5 3-6.1.6 3-6.1.7 3-6.1.8 3-7.1.1 3-7.1.2 3-7.1.3 3-8.1.1 3-8.1.2
Direction of circular motion
564
3-8.1.3
322 325 326 327 328 341 342 343 344 345 401
Constant force, motion, or flow Approximately constant force, motion, or flow Sinusoidal force, motion, or flow Pulse-shaped force, motion, or flow Burst of sinusoidal flow Saw-tooth shaped force, motion, or flow Oscillating motion Positive-going pulse Negative-going pulse Positive-going step Negative-going step Stepping function
Binary signal Direction in general, except for energy and signal flow Direction in general, except for energy and signal flow Working direction of hydraulic power Working direction of pneumatic power Alternative directions in general, except for energy, propagation, and signal flow Alternative directions in general, except for energy, propagation, and signal flow Bidirectional, simultaneously Direction of propagation, energy, or signal flow (simplex) Alternative directions of propagation, energy, or signal flow (half-duplex) Directions of propagation, energy, or signal flow, simultaneously in both directions possible (full-duplex)
Alternative directions of circular motion Limit
Description Momentary and partial reversal of motion Correlation indication Envelope, tank Liquid Gas Insulating material Permanent magnet Permanent-magnet type Bimetal Material of other type One item only Two identical items Three identical items Two or more identical items Two or more identical items Functional connection Mechanical link, shaft Mechanical link, shaft, wire Electrically insulating mechanical link, shaft, wire Pipeline, duct Group of pipelines, ducts Non-guided, electromagnetic beam Planned pipeline, duct Group of planned pipelines, ducts Pilot (control), drain, purge, or bleed line in fluid power systems Pure functional type Capillary type Pneumatic type Hydraulic type Electric type Unidirectional information bus type Bidirectional information bus type Flexible type Circular shape Rectangular shape Ridged shape Twisted pipeline, or duct Cable Twisting of pipelines Internal connection Flexible type Joint of connections Closed end of pipeline or duct Flange coupling, flange pair Flexible coupling Clamped flanged coupling Screwed joint Welded, brazed, or soldered joint Change of pipe dimension, pipe reducer Blind flange pair End cap Expansion loop Expansion sleeve Expansion bellows Port Quick-release coupling element of male type Quick-release coupling element of female type
--`,,``,`-`-`,,`,,`,`,,`---
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
35
ISO 14617-1:2005(E)
565
3-8.1.4
566
3-8.1.5
567
3-8.1.6
568
3-8.1.7
576 577 601
3-8.1.8 3-8.1.9 3-9.1.1
602
3-9.1.2
603 651
656
3-9.1.3 4-4.1.6 6-6.3.1 4-4.1.7 6-6.3.2 4-4.1.8 6-6.3.3 4-4.1.9 6-6.3.4 4-4.1.11 6-6.3.5 4-4.1.12
657
4-4.1.13
658 659
4-4.1.14 4-4.1.15 6-6.3.6 4-4.1.16
652 653 654 655
660
681 682 683 684
6-6.3.7 4-4.1.17 6-6.3.8 4-4.1.18 4-4.1.19 4-4.1.20 6-6.3.9 4-4.1.21 4-4.1.22 6-6.3.10 4-5.1.1 4-5.1.2 4-5.1.3 4-5.1.4
685 686
4-5.1.5 4-5.1.6
687 688 689 690 691
4-5.1.7 4-5.1.8 4-5.1.9 4-5.1.10 4-5.1.11
692 701
4-5.1.12 4-5.3.1
702
4-5.3.2
703
4-5.3.3
704
4-5.3.4
661 662 663 664 665 666
Description Quick-release coupling element which fits into another coupling element of the same type Quick-release coupling element of male type with automatic closing Quick-release coupling element of female type with automatic closing Quick-release coupling element which fits into another coupling element of the same type with automatic closing Fixed portion of a connector pair; socket Movable portion of a connector pair; plug Connection with n parallel, identical branches Transition between multi-line and singleline representation Exit from or entrance into a bundle Delay device Delay device Delay device with delay in both directions Automatic return device Detent for detaining in a discrete position Detent for detaining in a discrete position in disengaged position Detent for detaining in a discrete position in engaged position Indication of position without detention Detent for detaining in any position Detent for detaining in any position; drift to the left permitted Latching device Latching device in disengaged position Latching device in engaged position Blocking device Trip-free mechanism Interlocking device Manual actuator Manual actuator operated by pushing Manual actuator operated by pulling Manual actuator operated by pushing and pulling Manual actuator operated by turning Manual actuator in the form of a removable handle Manual actuator in the form of a key Manual actuator in the form of a lever Manual actuator in the form of a pedal Manual actuator in the form of a treadle Manual actuator with special shape for safety purpose Device for restricted access to actuator Indication of positions of a controlled element Indication of positions of a controlled element Indication of positions of a controlled element Indication of positions of a controlled element
RegisLocation tration (Partnumber subclause) 711
717 718 719 720 721
4-6.1.1 7-4.1.1 4-6.1.2 7-4.1.2 4-6.1.3 7-4.1.3 4-6.1.4 4-6.1.5 5-4.3.1.1 7-4.1.4 4-6.1.6 7-4.1.5 4-6.1.7 4-6.1.8 4-6.1.9 4-6.1.10 4-6.1.11
722
4-6.1.12
723
4-6.1.13
724
4-6.1.14
725 726 733
4-6.1.15 4-6.1.16 4-6.1.19
741 751 752 753 754 755
4-7.1.1 5-4.1.1 5-4.1.2 15-8.1.1 5-4.1.3 5-4.1.4 5-4.1.5
756
5-4.1.6
757 759 760
5-4.1.7 5-4.1.8 5-4.1.9
771
5-4.3.1.2 7-4.1.6 5-4.3.1.4 7-5.1.2 5-4.3.1.5 7-5.1.3 5-4.3.1.6 7-5.1.4 5-4.3.1.7 7-5.1.5 5-4.3.1.8 5-4.3.1.9 5-4.3.1.10 5-4.3.2.1 5-4.3.2.2 5-4.3.2.3 5-4.3.2.4 5-4.3.2.5 5-4.3.2.6 5-5.1.1 5-5.1.2 5-5.1.3 5-7.1.1 5-7.1.2 5-7.1.3
712 713 714 715 716
772 773 774 775 776 777 778 791 792 793 794 795 796 801 802 803 831 832 833
36
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Description Plunger; tracer Roller Cam profile Cam-operated actuator Fluid-level-operated actuator Float type Fluid-level-operated actuator Flow-target-operated actuator Single-acting hydraulic actuator Single-acting pneumatic actuator Double-acting hydraulic actuator Double-acting pneumatic actuator Double-acting hydraulic actuator with different active areas Double-acting pneumatic actuator with different active areas Actuator in the form of a single-acting fluid cylinder Actuator in the form of a double-acting fluid cylinder Single-acting diaphragm actuator Double-acting diaphragm actuator Actuator operating when a characteristic quantity passes a set value Actuating device Sensor Sensor Signal converter, measuring transducer Measuring transducer Signal converter, measuring transducer without connection between input and output circuits Signal converter, measuring transducer without connection between input and output circuits Thermocouple Tachometer generator Measuring transducer utilizing the synchro effect Displacer type Displacer Orifice plate type Orifice plate Flow nozzle type Flow nozzle Critical flow nozzle type Critical flow nozzle Venturi tube type Venturi element Flow elbow type Variable area flow type Pitot tube type Rotatable stator type Controlling Differential type Resolving/Receiver Torque measurement/Transformer Measuring transducer; transmitter Boss with well Insertion pipe Boss with insertion pipe Thermometer Indicating measuring instrument Recording measuring instrument
© ISO 2005 – All rights reserved Not for Resale
--`,,``,`-`-`,,`,,`,`,,`---
RegisLocation tration (Partnumber subclause)
ISO 14617-1:2005(E)
834 841 842 843 851 863 864 865 866 891 892 893 894 895 896 1011 1021
5-7.1.4 5-8.1.1 5-8.1.2 5-8.1.3 5-9.1.1 5-10.1.1 5-10.1.2 5-10.1.3 5-10.1.4 5-12.1.1 5-12.1.2 5-12.1.3 5-12.1.4 5-12.1.5 5-12.1.6 6-5.1.1 6-6.1.1
1022
6-6.1.2
1041 1042
6-7.1.1 6-7.1.2
1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072
6-7.3.1.1 6-7.3.1.2 6-7.3.1.3 6-7.3.1.4 6-7.3.1.5 6-7.3.1.6 6-7.3.1.7 6-7.3.1.8 6-7.3.1.9 6-7.3.1.10 6-7.3.1.11 6-7.3.1.12 6-7.3.1.13 6-7.3.1.14 6-7.3.1.15 6-7.3.1.16 6-7.3.1.17 6-7.3.1.18 6-7.3.1.19 6-7.3.1.20 6-7.3.1.21 6-7.3.1.22
1073 1074 1075 1076
6-7.3.1.23 6-7.3.1.24 6-7.3.1.25 6-7.3.1.26
1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1101 1102 1103
6-7.3.2.1 6-7.3.2.2 6-7.3.2.3 6-7.3.2.4 6-7.3.2.5 6-7.3.2.6 6-7.3.2.7 6-7.3.2.8 6-7.3.2.9 6-7.3.2.10 6-7.3.2.11 6-7.3.4.1 6-7.3.4.2 6-7.3.4.3
1104
6-7.3.4.4
2001
7-4.1.7
RegisLocation tration (Partnumber subclause)
Description Integrating measuring instrument Counter Clock Master clock Display unit Mechanical indicator Electromechanical indicator Electromechanical position indicator Acoustic signalling device Amplifier Amplifier Amplifier with return channel Amplifier with return channel Feedback controller Feedback controller Point of measurement Manual operation of a final controlling element Automatic operation of a final controlling element Information processing function Information processing function performed by time-sharing Alarming Displaying discrete state Controlling Density/Difference Electric variable/Sensing Flow rate/Ratio, fraction Gauge, position, length/Viewing Hand Indicating Power/Scanning Time/Time rate of change Level Moisture, humidity/Momentarily User's choice User's choice Pressure/Connection of test point Quality/Integral, total/Integrating, summing Radiation/Registering, recording Speed, frequency/Switching Temperature/Transmitting Multi-variable/Multi-function User's choice/Impact on process by valve, pump, etc. Weight, force/Multiplying Unclassified User's choice/Converting, computing Number of events, quantity/Emergency or safety acting High Very high Very high Extremely high Extremely high Low Very low Very low Extremely low Extremely low High or low Primary location in a central control room Auxiliary location in a central control room Primary location in a local control room or on a local control panel Auxiliary location in a local control room or on a local control panel Weight
2002 2003 2004 2005
2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2061 2062 2063 2064 2065 2066 2067 2068 2101 2102 2103 2104 2111 2112 2113 2114 2115 2121 2122 2123 2124 2125 2126
7-4.1.11 7-4.1.12 7-4.1.13 4-4.1.1 7-4.1.14 4-4.1.2 7-4.1.15 4-4.1.3 7-4.1.16 4-4.1.4 7-4.1.17 4-4.1.5 7-4.1.18 7-4.1.19 7-4.1.20 7-4.1.21 7-5.1.1 7-5.1.6 7-5.1.7 7-5.1.8 7-5.1.9 7-5.1.10 7-5.1.11 11-4.1.2 12-4.1.10 7-5.1.12 15-10.3.5 7-5.1.13 7-5.1.14 7-5.1.15 7-5.1.16 7-5.1.17 7-5.1.18 7-5.1.19 7-6.1.1 15-10.3.6 7-6.1.2 7-6.1.3 7-6.1.4 7-6.1.5 7-6.1.6 7-6.1.7 7-6.1.8 8-4.1.1 8-4.1.2 8-4.1.3 8-4.1.4 8-4.3.1.1 8-5.3.1 8-4.3.1.2 8-5.3.2 8-4.3.1.7 8-4.3.1.8 8-4.3.1.9 8-4.3.2.1 8-4.3.2.2 8-4.3.2.3 8-4.3.2.4 8-4.3.2.5 8-4.3.2.6
Spring Membrane type; diaphragm type Membrane; diaphragm Membrane; diaphragm Joint of two mechanical parts permitting motion of the parts in two or more dimensions Bearing Buffer head Mechanical gear pair Clutch, disengaged in unactuated state Clutch, engaged in unactuated state Brake, disengaged in unactuated state Brake, applied in unactuated state Wheel Ball Ball Restrictor Flow straightener Silencer Viewing glass Rupturing disc Flame arrestor Spray nozzle Siphon, anti-siphon trap Vent Drain funnel Stack Pig receiver: launcher Blind Spectacle blind in closed position Spectacle blind in open position Container, tank, cistern for atmospheric pressure Pressure or vacuum vessel Pressure or vacuum vessel Bunker Open store Shelf store Barrel Bag Two-way valve Angled two-way valve Three-way valve Four-way valve Non-return function; check function Safety function L-bore in a three- or four-way valve T-bore in a three- or four-way valve Double L-bore in a four-way valve Globe type Ball type Plug type Gate type Needle type Disc or butterfly type
37
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
4-4.1.10 7-4.1.8 5-4.3.1.3 7-4.1.9 7-4.1.10 3-5.1.2
Description
--`,,``,`-`-`,,`,,`,`,,`---
RegisLocation tration (Partnumber subclause)
Not for Resale
ISO 14617-1:2005(E)
RegisLocation tration (Partnumber subclause) 8-4.3.2.7 8-4.3.2.8 8-4.3.2.9 8-4.3.2.10 8-4.3.2.11 8-5.1.1 8-6.1.1 8-6.1.2 8-6.1.3 8-6.3.1 8-6.3.2 8-6.3.3 8-6.3.4 8-6.3.5
2176 2177 2181
8-6.3.6 8-6.3.7 8-8.1.1
2301 2302
9-4.1.1 15-10.3.7 9-4.1.2
2303
9-4.1.3
2304
9-4.1.4
2321
2323 2331 2332 2333 2334 2335 2336 2337 2338 2339 2351 2352 2353 2401 2402 2403
9-4.3.5 10-4.3.8 9-4.3.6 10-4.3.9 9-4.3.7 9-5.1.1 9-5.1.2 9-5.1.3 9-5.1.4 9-5.1.5 9-5.1.6 9-5.1.7 9-5.1.8 9-5.1.9 9-6.1.1 9-6.1.2 9-6.1.3 10-4.1.1 10-4.1.2 10-4.1.3
2404
10-4.1.4
2405
5-4.3.1.11 10-4.1.5 10-4.1.6 4-6.1.17
--`,,``,`-`-`,,`,,`,`,,`---
2127 2128 2129 2130 2131 2151 2161 2162 2163 2171 2172 2173 2174 2175
2322
2406 2407
10-4.1.7 2408
4-6.1.18 10-4.1.8
2409 2410 2411
10-4.1.9 10-4.1.10 10-4.1.11
2412
10-4.1.12
Description Piston type, plunger type Diaphragm type Hose type Reduced bore Jacket Two- or three-way damper Valve for fluid power systems Seat of a non-return valve Moving part of a non-return valve Open flow path Closed flow path Closed flow path of a leak-free valve Flow to open air Infinite number of intermediate positions of a valve Transitory position Affected area Self-operating release valve, steam trap or vent Liquid pump Gas pump, vacuum pump, compressor, fan Liquid pump with alternative directions of flow Gas pump, compressor, fan with alternative directions of flow Positive displacement type Rotodynamic type Turbo-molecular type Ejector pump Diffusion pump Diffusion-ejector pump Gas-lift pump Entrapment pump Adsorption pump Getter pump Getter ion pump Cryo pump Electric liquid pump Electric induction liquid pump Electric induction liquid pump Hydraulic pump Pneumatic pump, compressor Hydraulic pump with alternative directions of flow Pneumatic pump with alternative directions of flow Rotary type, turbine type Hydraulic motor Pneumatic motor Actuator in the form of a hydraulic motor with alternative directions of flow Hydraulic motor with alternative directions of flow Actuator in the form of a pneumatic motor with alternative directions of flow Pneumatic motor with alternative directions of flow Hydraulic pump/motor Pneumatic pump/motor Hydraulic pump/motor acting as a pump with one direction of flow and as a motor in the other direction of flow Pneumatic pump/motor acting as a pump with one direction of flow and as a motor in the other direction of flow
RegisLocation tration (Partnumber subclause) 2413
10-4.1.13
2414
10-4.1.14
2415 2416 2431 2432
10-4.1.15 10-4.1.16 10-5.1.1 10-5.1.3
2434 2435 2436 2441
10-5.1.5 10-5.1.2 10-5.1.4 10-6.1.1
2442
10-6.1.5
2443 2444 2445
10-6.1.7 10-6.1.11 10-6.1.2
2446
10-6.1.3
2447
10-6.1.4
2448
10-6.1.6
2449
10-6.1.8
2450
10-6.1.9
2451
10-6.1.10
2501
11-4.1.3 11-7.3.6 12-4.3.7 15-10.3.8 11-4.1.4 11-5.1.1 11-5.1.2 11-5.1.3 11-5.1.4 11-5.1.5 11-5.1.6 11-5.1.7 11-5.1.8 11-6.1.1 11-7.1.1 11-7.1.2 11-7.1.3 11-7.3.2 12-4.3.9 15-9.3.1 15-10.3.9 11-8.1.1 11-9.1.1 11-9.1.2 11-9.1.3 11-9.1.4 11-9.1.5 11-10.1.1 11-10.1.2 11-10.1.3 11-11.1.1 12-4.1.1 12-4.1.3 12-4.1.4
2502 2511 2512 2513 2514 2515 2516 2517 2518 2521 2531 2532 2533 2541
2551 2571 2572 2573 2574 2575 2581 2582 2583 2591 2601 2602 2603
38
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Description Hydraulic pump/motor acting as a pump with alternative directions of flow or as a motor with alternative directions of flow Pneumatic pump/motor acting as a pump with alternative directions of flow or as a motor with alternative directions of flow Hydraulic semi-rotary motor Pneumatic semi-rotary motor Linear pneumatic-hydraulic converter Linear pneumatic-hydraulic pressure intensifier Hydraulic rotary torque converter Continuous pneumatic-hydraulic converter Continuous pneumatic-hydraulic intensifier Single-acting hydraulic extension cylinder with single-ended piston rod Double-acting hydraulic cylinder with single-ended piston rod Single-acting hydraulic telescopic cylinder Cushion Single-acting pneumatic extension cylinder with single-acting piston rod Single-acting hydraulic retraction cylinder with single-ended piston rod Single-acting pneumatic retraction cylinder with single-ended piston rod Double-acting pneumatic cylinder with single-ended piston rod Single-acting pneumatic telescopic cylinder Double-acting hydraulic telescopic cylinder Double-acting pneumatic telescopic cylinder Heating or cooling coil Heat exchanger type Finned tube Heat exchanger with straight tubes Heat exchanger of floating type Heat exchanger with U-shaped tubes Heat exchanger with coil-shaped tubes Heat exchanger of double-pipe type Heat exchanger of plate type Heat exchanger of spiral type Regenerative pre-heater Cooling tower Boiler, steam generator Boiler with dome Furnace Fired type
Heat pump, refrigerator, or freezer Steam turbine Steam turbine with centre inlet Gas turbine Jet motor Turbo-fan jet motor Reciprocating steam engine Internal combustion engine External combustion engine Flare Device for separating Screen or filter element Bed filter element of fixed type
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
2604 2605 2606 2607 2608 2621 2622 2623 2624 2651 2661 2671 2672 2673 2691 2801 2802 2803 2804 2805 2806 2807
12-4.1.5 12-4.1.6 12-4.1.7 12-4.1.8 12-4.1.9 12-4.3.3 12-4.3.10 12-4.3.11 12-4.3.12 12-5.1.1 12-5.3.1 12-6.1.1 12-6.1.2 12-6.1.3 12-7.1.1 13-4.3.1 13-4.3.2 13-4.3.3 13-4.3.4 13-4.3.5 13-4.3.6 13-4.3.7
2808
13-4.3.8
2809
13-4.3.9
2810 2811 2812 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823
13-4.3.10 13-4.3.11 13-4.3.12 13-4.3.14 13-4.3.15 13-4.3.16 13-4.3.17 13-4.3.18 13-4.3.19 13-4.3.20 13-4.3.21 13-4.3.22 13-4.3.23
2824
13-4.3.24
2825
13-4.3.25
2826 2827 2828 3001
13-4.3.26 13-4.3.27 13-4.3.28 15-4.1.1
3002
15-4.1.2
3003
15-4.1.3
3004 3005 3051
15-4.1.4 15-4.1.5 15-4.3.1
3052
15-4.3.2
3053
15-4.3.3
3054
15-4.3.4
3055
15-4.3.5
RegisLocation tration (Partnumber subclause)
Description Bed filter element of fluidized type Scraper Disc with knife Plate for separating Centrifuge rotor Cyclonic type Chemical type Biological type Ion exchange type Purifier using conversion Catalytic type Device for mixing Rotary mixing element Static mixing element Air conditioner for pneumatic systems Casting or moulding Material forming by forging Material forming by pressing Material forming by bending or folding Material forming by rolling Material forming by extruding or pultruding Heat treatment, for example, annealing or tempering Size reduction by crushing, breaking, or pulverization Size enlarging by sintering, agglomeration, coagulation, or flocculation Dividing material Dividing by sawing Dividing by shearing Dividing by laser beam Boring, drilling Reaming Planing Broaching Tapping Threading Milling Turning Joining, for example, by riveting, glueing, welding, brazing or soldering Surface treatment by removal of material, for example, by grinding, honing, polishing, or sanding Surface treatment without removal of material, for example, by rolling Calendering Coating, for example, painting Sealing, for example, by caulking Sleeve for penetration of construction, for example, a wall; wall duct Seal for penetration of construction, for example, a wall; sealed wall duct Seal for penetration of construction partitioning a space with different air pressure. Anchor point Guide bracket, for example, for pipelines Located underground, for example, pipeline, cable, or joint Located underwater, for example, pipeline or cable Located on poles, for example, pipeline, cable, or power line Located in a circular duct or pipe, for example, conductors or cables Located in a rectangular duct, for example, pipelines, conductors, or cables
3056
15-4.3.6
3057
15-4.3.7
3058
15-4.3.8
3059
15-4.3.9
3060
15-4.3.10
3061 3062 3063 3064 3065 3066 3067 3068 3069 3081 3082
14-4.3.5 15-4.3.11 15-4.3.12 15-4.3.13 15-4.3.14 15-4.3.15 15-4.3.16 15-4.3.17 15-4.3.18 15-4.3.19 15-5.1.1 15-5.1.2
3083 3084 3085 3086
15-5.1.3 15-5.1.4 15-5.1.5 15-5.1.6
3087
15-5.1.7
3101 3102 3103 3104 3105 3106 3107 3108 3109 3121 3122 3123 3124 3132 3133 3134 3141 3142 3143 3144 3151 3201 3202 3203 3204 3205 3206 3207 3801 3806 3807 3808 3821 3822 3823 3824 3825
15-6.1 15-6.2 15-6.3 15-6.4 15-6.5 15-6.6 15-6.7 15-6.8 15-6.9 15-7.1 15-7.2 15-7.3 15-7.4 15-8.1.2 15-8.1.3 15-8.1.4 15-8.3.1 15-8.3.2 15-8.3.3 15-8.3.4 15-9.3.2 15-10.3.10 15-10.3.11 15-10.3.12 15-10.3.13 15-10.3.14 15-10.3.15 15-10.3.16 14-4.1.1 14-4.1.2 14-4.1.3 14-4.1.4 14-4.3.6 14-4.3.7 14-4.3.8 14-4.3.9 14-4.3.10
Located on a tray, for example, pipelines, conductors, or cables; endpoints indicated Located on a tray, for example, pipelines, conductors, or cables; continuous Going to a storey above, for example, pipeline, cable, or conductor bundle Going to a storey below, for example, pipeline, cable, or conductor bundle Going between a storey above and a storey below, for example, pipeline, cable, or conductor bundle Slope, for example, of a pipeline Information Blocking of electric current Sound Control Alarm Light alarm Sound (acoustic) alarm Vibrating (tactile) alarm Connection box, junction box Consumers terminal, service entrance equipment Distribution centre Enclosure Cross-connection device Square-shaped access chamber, inspection well Circular-shaped access chamber, inspection well Outlet tap Outlet tap in taphole Outlet tap on wall Mixing outlet tap Mixing outlet tap in taphole Mixing outlet tap on wall Self-closing outlet tap Hand-held shower Flushing valve with pipe interrupter Underground hydrant Above ground hydrant Wall hydrant First aid fire hose reel Detector, pilot switch Electric window foil Protection unit for potable water systems Sound Fire Smoke Dust Air conditioning Heat pump type; temperature increase Heat pump type; temperature decrease Electric type Sewage water Salt Pond Waste Conveyor Feeding funnel, hopper Vane feeder rotor Turn table Belt type Belt type with scraper flights Chain or wire driven type Roller type Ropeway type, overhead type
39
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Description
Not for Resale
--`,,``,`-`-`,,`,,`,`,,`---
RegisLocation tration (Partnumber subclause)
ISO 14617-1:2005(E)
RegisLocation tration (Partnumber subclause)
3832 3833 3834 3841 3842 3843 3851 3852 3853 3854 3855 3861 3862 3863
14-4.3.11 14-4.3.12 14-4.3.13 15-8.3.5 14-4.3.14 14-4.3.15 14-4.3.16 14-5.1.1 14-5.1.2 14-5.1.3 14-6.1.1 14-6.1.2 14-6.1.3 14-6.1.4 14-6.1.5 14-7.1.1 14-7.1.2 14-7.1.3
3864 3865 3866 3867 3868 3869 3870 3871 3872 3873
14-7.1.4 14-7.1.5 14-7.1.6 14-7.1.7 14-7.1.8 14-7.1.9 14-7.1.10 14-7.1.11 14-7.1.12 14-7.1.13
3874 3875 3881 IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC
14-7.1.14. 14-7.1.15 14-7.1.16 5-4.3.1.13 5-4.3.1.14 5-4.3.1.16 5-4.3.1.12 5-4.3.1.15 5-4.3.1.17 5-4.3.1.18 5-4.3.1.19 5-4.3.1.20 11-7.3.1 11-7.3.4 11-7.3.3 11-7.3.5 12-4.3.8 12-4.3.5 12-4.3.4 13-4.3.13
Bucket type Screw type Vibration, vibrating type Gravity type Spiral gravity (sliding) type Escalator function Crane Lift, hoist Materials handling robot Mono-rail Double rail, railway track Traverser, traversing platform Track turntable Railway wagon tip, platform tip Industrial truck Fork lift truck Driverless, automatic fork lift truck, including remote controlled Container truck Wheel loader Log loader Bulldozer Lorry Covered lorry, van Tank truck Open railway wagon or open trailer Covered railway wagon or covered trailer Railway wagon or trailer for non-solid material Railway tanker or trailer tanker Locomotive Cargo ship Capacitive type Conductive electrode type Receiving ultrasonic type Strain gauge type Transmitting ultrasonic type Transmitting and receiving ultrasonic type Radioactive type Optical type Semiconductor type Ionizing radiation type, nuclear type Electric electrode type Electric heating element type Electric induction type Electro-thermal type Electromagnetic type Electrostatic type Laser generator
--`,,``,`-`-`,,`,,`,`,,`---
3828 3830 3831
Description
40
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Annex C (informative) Cross-reference index
This index of cross-references is intended to link those graphic symbols with registration numbers to corresponding items in other, existing ISO and IEC standards. Symbol registration No.
Item in existing International Standard IEC 60617
ISO 1219-1
ISO 3511
ISO 4067-1
ISO R538
101
02-01-01 to -03
5.3.2 to 5.3.5
3-3.1.1.1 3-3.1.2.1 3-3.3.1
4.5.0 5.3.0
1.3; 1.4
106
12-09-01 to -50
107
12-54.6
111, 112
02-17-06, 06A
113, 114
02-17-07 02-08-07
115
02-03-12 12-09-08A 12-09-08B 12-29
119
02-08-04
121
02-13-06
122
02-13-07
123
02-08-05 12-40-01
124
12-30-01
3-3.1.2.6
125
IEC 60417-5302
126
12-09-11
127
13-05-13
128 129
Others
9.5.2.2 12-09-01
130 131
(10-11-01)
132 133, 134
10-17.1
2-8.3
135, 136
10-17.1
2-8.4
137
10-17-02
138
2-8.5
139
2-8.6
140
12-38-05
41
--`,,``,`-`-`,,`,,`,`,,`---
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
141
08-02-08
142
12-27-02
143
12-27-01
144
02-03-11
145
12-54-01
148
(08-01-01)
149
(08-04-12) (09-06-03)
150
(09-06-06)
151
(09-06-04)
152
(09-06-05)
153
(09-06-03)
154
02-17-05
ISO 1219-1
ISO 3511
ISO 4067-1
3-3.1.1.2
(8.0.0)
ISO R538
Others
(8.0.1)
161
ISO 31-11
162
2-8.13
163
2-8.7
171
02-06-01
172
02-06-02
173
02-06-03
174
02-06-04
175
02-06-05
181
12-07-01, 02
182
12-07-03 to -06
183
12-10-01 13-05-01, 02
201
02-03-01
202
02-03-02
203
02-03-05
204
02-03-03
205
02-03-04
211
02-03-07
212
03-03-09
221
02-02-03
2-10.2.1 to -10.2.4
5.4.2.3
222 223
02-02-12
224
02-02-04
225
10-12-04
226
02-10-03 --`,,``,`-`-`,,`,,`,`,,`---
42
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
227
02-10-06
228
02-04-06
229
02-10-01
230
02-10-02
231
02-10-04
232
02-10-05
233
02-03-07
234
02-17-08
2-8.11 3-3.1.1.2.1
235
02-17-09
2-8.11 3-3.1.1.2.2
236
12-33-03, 05 to 08
241, 242
02-04-01
ISO 1219-1
ISO 3511
5.4.2.1 5.4.1.1
243
5.4.1.1
244
5.4.1.2 5.4.2.1
ISO 4067-1
ISO R538
Others
4.1.8
1.1.1
ISO 3753-4.5.1 ISO 3952-1-1.8.1 IEC 60375
245, 246
02-04-02
ISO 3952-1-1.8.5
249
02-05-01
250
02-05-03
251
02-05-02
252
02-05-04
253
02-05-05
254
10-07-15
6.2.2.4
ISO 3952-1-1.8.1
255
02-04-03
5.4.2.2
ISO 3952-1-1.8.1
256
02-04-04
5.4.2.2
ISO 3952-1-1.8.5
261
02-04-05
1-5.1.4
ISO 3952-1-1.8.10
262
ISO 3952-1 1.8.4
263
06-09-03 07-15-16 to -18
301
02-01-04, 05
321
02-97-03
3-3.3.3.4
322
02-07-04
3-3.3.3.5
325
02-07-02
326
02-17-03
327 328
IEC 60375 IEC 61082-1 (Figure 68) IEC 61082-2 (Figure 20) ISO 3753-4.7.1
3-3.3.3.6
--`,,``,`-`-`,,`,,`,`,,`---
5.3.6
IEC 60051-1-F-15
02-07-01
43
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
341 to 343
03-01-02
344
03-01-03
ISO 1219-1
ISO 3511
ISO 4067-1
ISO R538
Others
3-3.4.3.1
345
IEC 61082-1-4.6.3
401
03-01-01
1-5.1.2
402 to 404
02-12-01, 04
5.3.1.4; 8.2.2
3-3.2.4.1
405
02-12-01
5.3.1.1, 2
1-5.1 to -5.4 3-3.4
ISO 3952-1-3.2 4.1.0 to 2; 5.1.0
1.1
4.1.7
2.4
ISO 3753-4.5.1
406 411
10-01-06
412, 413 422
5.3.1.2
431
1-5.1.2 3-3.4.2.1
432
2-5.4 3-3.4.3.4
433
2-5.2 3-3.4.3.2
434
2-5.3 3-3.4.3.3
435
5.4.3.1
442
12-55-01
443
12-55-02
444
03-01-06
445
10-07-03
446
10-07-01
447
10-07-04
448
10-07-11
449
03-01-09, 10
450
03-01-08
2-5.1 3-3.4.3.1
6.1.2.3
451
IEC 61082-2-2.4.4.2
501
6.1.2.3 03-02-01
503
6.1.2.1
1-5.1.3
4.1.4; 4.2.0
2.2, 3
4.2.2
2.5
ISO 3753-4.5.2
5.4.3.2
511
--`,,``,`-`-`,,`,,`,`,,`---
452
512 513 514
2.7
515
ISO 2553
44
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
ISO 1219-1
ISO 3511
ISO 4067-1
ISO R538
517
4.2.5
2.13
518
4.1.11
2.12
531
4.1.10
2.10
532
4.1.10
2.9
533
4.1.10
2.11
Others
516
561 563
6.2.2.3
4.2.1
564
6.2.2.3
4.2.1
565
6.2.2.3
566
6.2.2.3
567
6.2.2.3
568
6.2.2.3
576
03-03-09
577
03-03-10
601
03-02-09
2.8
602
IEC 61082-1-4.4.7.2
603
IEC 61082-1-4.4.7.2 02-12-05
652
02-12-06
653
07-05-05
654
02-12-07
7.3.2.3
655
02-12-08
7.2.1.3
656
02-12-09
7.2.1.3
657
02-12-10
7.2.1.3
--`,,``,`-`-`,,`,,`,`,,`---
651
2-3.7 3-3.2.3.5
4.3.5
659
2-3.7 3-3.2.3.5
4.3.5
660
2-3.7
658
(3.12)
7.2.1.3
661 to 663
02-12-12, 13
7.2.1.4
3-3.2.3.1, 3-3.2.3.2
664
02-12-14
665
07-13-11
666
02-12-11
681
02-13-01
7.3.1.1
3-3.2.2.1
682
02-13-05
7.3.1.2
683
02-13-03
7.3.1.3
684
4.1
ISO 3753-4.6.4
7.3.1.4
45
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
6.0.0
Not for Resale
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
685
02-13-04
686
02-13-12
687
02-13-13
688
02-13-11
7.3.1.5
689
02-13-10
7.3.1.6
ISO 1219-1
ISO 3511
ISO 4067-1
ISO R538
3-3.2.2.7
6.0.4
4.5
725
2-6.4.1 3-3.2.2.2
6.0.6
4.8
726
2-6.4.2
690
Others
7.3.1.7
691
02-13-08
692
02-13-02
701 to 704
07-11-06
711
7.3.2.1
712
02-13-15
713
02-13-18
714
02-13-16
715
02-14-01
716
02-14-03
7.3.2.4
717
7.3.4.2.5
718
7.3.4.2.1
719
8.1.3.9
720 721 722 723
8.2.2.1
724
8.2.2.3
733
07-16-01
741
(02-13-20)
751, 752
(09-09-09)
3-3.3.1
753, 754
02-17-06 08-07-01 to -03
3-3.1.2.6
755, 756
02-17-07
757
08-06-01, 02
759
06-04-01
760
08-09-02
6.0.1
ISO 3753-4.6.5
(7.0)
3-3.3.3.2 11.1.2.5
3-3.3.9.3
771
3-3.3.5.3
772
3-3.3.2.5
773
3-3.3.2.4
--`,,``,`-`-`,,`,,`,`,,`---
46 Organization for Standardization Copyright International Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
ISO 1219-1
ISO 3511
ISO 4067-1
ISO R538
Others
774 775
3-3.3.2.3
776 777
3-3.3.2.6
778 791 to 796
08-09-02
801
3-3.3.1.3
802
3-3.3.1.4
803
3-3.3.1.5
--`,,``,`-`-`,,`,,`,`,,`---
831
08-02-14
11.1.2.3
3-3.3.3.7
7.0.0
832
08-01-01
11.1
3-3.1.1.2
8.0.0
833
08-01-02
3-3.1.1.3
8.0.1
834
08-01-03
(11.1.2.4.3)
841
02-14-02
11.1.2.1.4, 5
842
08-08-01
843
08-08-02
851
12-52-01
863
(08-10-03)
864
08-10-03
865
08-10-04
866
08-10-06 to -12
891, 892
10-15-01, 02; 12-29-01, 02
893, 894
10-15-04 11-06-04
895, 896
06-19-01
1.4
3-3.1.2.8
3-3.1.2.2
1011
1-6.1.7
1021
1-3.5.3
1022
1-3.5.1
1041
1-3.2
1042
4-3.1
1051 to 1076
1-Table 2-Table
1081
2-Table, note 4
1082, 1083 1084, 1085 1086
2-Table, note 4
47
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
ISO 1219-1
ISO 3511
ISO 4067-1
ISO R538
Others
1087, 1088 1089, 1090 1091 1101
1-5.2
1102 1103
2-7
1104
2-7
2001
3-3.2.2.8
6.0.3
4.4
3-3.2.2.6
6.0.2
4.3
3-3.3.7.3
6.0.6
4.8
2002
5.4.3.6
2003, 2004 2005
ISO 3952-1-2.1.1
2006
ISO 3953-4-9.8.1
2007
--`,,``,`-`-`,,`,,`,`,,`---
2008
02-12-23
2009
02-12-17
2010
02-12-18
2011
02-12-22
2012
02-12-21
2013
2014, 2015 2031
5.4.3.7
3-3.5.1.7
2032 2033
11.2.4
5.3.4
2034 2035 2036
5.2.5
2037
5.3.3
2038
6.2
2039
4.3.11
2040
6.3 6.1
2041 2042
4.4.4
2043 2044, 2045
2.14
2061
5.3.6.1
2062, 2063
5.3.6.2; 8.4.2
ISO 3753-4.7.1
2064
48
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
ISO 1219-1
ISO 3511
ISO 4067-1
ISO R538
Others
1-3.6 3-3.2.1.1
4.3.0
1.2
ISO 3753-4.6
2102
4.3.1
3.2
2103
4.3.2
3.3
2104
4.3.3
2111
4.3.4
3.4
2112
4.3.5
3.11
2065 2066 2067 2068 2101
11-03-09
2113
3.25
2114 2115 2121
3.1 to 3
2122 2123 2124
3.23 9.5.2.1.2
3.22
ISO 3753-4.6.1
2125
3.15
ISO 3753-4.6.3
2126
3.18
2127 2128 2129 2130 2131 2151
5.2.2
2161
5.3.5.1
2162
5.4.3.8
2163
5.3.2.3
2171
5.4.2.1
2172
5.4.3.2
2173
9.3.2
2174
6.2.2.2
2175
9.1.1.8
2176
9.1.1.7
2177
7.3.4.1.2
2181
4.3.12
2301
4.5.6
5.6
--`,,``,`-`-`,,`,,`,`,,`---
49
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
ISO 1219-1
ISO 3511
ISO 4067-1
2302
ISO R538
Others
4.5.6; 5.3.1
2303 2304 2321
ISO 3753-4.1.1
2322 2323
ISO 3753-4.1.1.6
2331
ISO 3753-4.1.1.4
2332
ISO 3753-4.1.1.5
2333 2334 2335
ISO 3753-4.1.2
2336
ISO 3753-4.1.2.1
2337
ISO 3753-4.1.2.2
2338 2339
ISO 3753-4.1.2.4
2351 2352 2353 2401
8.1.2.1
2402
8.1.2.3
2403 2404 2405 2406
8.1.2.2
2407 2408
8.1.3.3
2409
8.1.3.4
2410 2411 2412 2413
8.1.3.5
2414
(8.1.3.5)
2415
(8.1.3.6)
2416
8.1.3.6
2431
8.3.1
2432
8.3.2
2433
8.3.2
--`,,``,`-`-`,,`,,`,`,,`---
50
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
ISO 1219-1
2434
8.3.2
2435
8.3.1
2436
8.3.2.1
2441
02-13-21
8.2.2.1
2442
02-13-22
8.2.2.3
2443
8.2.3.1
2444
8.2.2.4
2445
8.2.2.1
2446
(8.2.2.2)
2447
(8.2.2.2)
ISO 3511
ISO 4067-1
2-6.4.5 3-3.2.2.4
6.0.5
ISO R538
Others
ISO 3753-4.6.6
2448 2449
8.2.3.1
2450
8.2.3.2
2451
(8.2.3.2)
2501
10.2.2.7
4.5.5; 5.3.5, 6
2502 2511 2512 2513 2514 2515 2516 2517 2518 2521 2531 --`,,``,`-`-`,,`,,`,`,,`---
2532 2533 2541
4.5.2, 4.5.3
2551 2571 2572 2573 2574 2575 2581
51
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
ISO 1219-1
ISO 3511
ISO 4067-1
ISO R538
Others
2582 2583 2591 2601 2602
5.5 5.3.1.2
4.5.7
5.4
2603 2604 2605 2606 2607 2608 2621 2622 2623 --`,,``,`-`-`,,`,,`,`,,`---
2624 2651 2661 2671 2672 2673 2691
10.2.2.6
2801 2802 2803 2804
ISO 7000-0390
2805
ISO 7000-0194
2806 2807
ISO 7000-0535
2808 2809 2810 2811
ISO 7000-0303
2812
ISO 7000-0387
2814 2815
ISO 7000-0268
2816
ISO 7000-0291
2817
ISO 7000-0368
52
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
ISO 1219-1
ISO 3511
ISO 4067-1
ISO R538
Others
2818
ISO 7000-0292
2819
ISO 7000-0384
2820
ISO 7000-0382
2821
ISO 7000-0371
2822
ISO 7000-0365
2823 2824 2825 2826
ISO 7000-0883
2827 2828 3001 3002 3003
03-04-07
3004 3005 3051
11-03-01
3052
11-03-02
3053
11-03-03
3054
11-03-04
3055 3056 3057 3058
11-12-01
3059
11-12-02
3060
11-12-03
3061 3062 3063 3064
10-01-04
3065
IEC 61175
3066
IEC 61175
3067 3068 3069 3081
11-12-05
3082
11-12-06
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
--`,,``,`-`-`,,`,,`,`,,`---
Not for Resale
53
ISO 14617-1:2005(E)
Symbol registration No.
Item in existing International Standard IEC 60617
3083
11-12-07
ISO 1219-1
ISO 3511
ISO 4067-1
ISO R538
Others
3085
11-04-03
3086
11-04-07 --`,,``,`-`-`,,`,,`,`,,`---
3084
3087 3101…3124 3132
07-16-01
3133…3808 3821
ISO 7000-0229
3822…3881
54
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
ISO 14617-1:2005(E)
Bibliography
ISO 561:1989, Coal preparation plants — Graphical symbols
[2]
ISO 1219-1:1991, Fluid power systems and components — Graphic symbols and circuit diagrams — Part 1: Graphic symbols
[3]
ISO 1219-2:1995, Fluid power systems and components — Graphic symbols and circuit diagrams — Part 2: Circuit diagrams
[4]
ISO 3511-1:1977, Process measurement control functions and instrumentation — Symbolic representation — Part 1: Basic requirements
[5]
ISO 3511-2:1984, Process measurement control functions and instrumentation — Symbolic representation — Part 2: Extension of basic symbols
[6]
ISO 3511-3:1984, Process measurement control functions and instrumentation — Symbolic representation — Part 3: Detailed symbols for instrument interconnection diagrams
[7]
ISO 3511-4:1985, Industrial process measurement control functions and instrumentation — Symbolic representation — Part 4: Basic symbols for process computer, interface, and shared display/control functions
[8]
ISO 3753:1977, Vacuum technology — Graphical symbols
[9]
ISO 3952-1:1981, Kinematic diagrams — Part 1: Graphical symbols
[10]
ISO 3952-2:1981, Kinematic diagrams — Part 2: Graphical symbols
[11]
ISO 3952-3:1979, Kinematic diagrams — Part 3: Graphical symbols
[12]
ISO 3952-4:1984, Kinematic diagrams — Part 4: Graphical symbols
[13]
ISO 4067-1:1984, Technical drawings — Installations — Part 1: Graphical symbols for plumbing, heating, ventilation and ducting
[14]
ISO 4067-2:1980, Building and civil engineering drawings — Installations — Part 2: Simplified representation of sanitary appliances
[15]
ISO 4067-6:1985, Technical drawings — Installations — Part 6: Graphical symbols for supply water and drainage systems in the ground
[16]
ISO 5784-1:1988, Fluid power systems and components — Fluid logic circuits — Part 1: Symbols for binary logic and related functions
[17]
ISO 5784-2:1989, Fluid power systems and components — Fluid logic circuits — Part 2: Symbols for supply and exhausts as related to logic symbols
[18]
ISO 5784-3:1989, Fluid power systems and components — Fluid logic circuits — Part 3: Symbols for logic sequencers and related functions
[19]
ISO 5859:1991, Aerospace — Graphic symbols for schematic drawings of hydraulic and pneumatic systems and components
[20]
ISO 81714-1:1999, Design of graphical symbols for use in the technical documentation of products — Part 1: Basic rules
--`,,``,`-`-`,,`,,`,`,,`---
[1]
55
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
ISO 14617-1:2005(E)
[21]
ISO/R 538:1967, Conventional signs to be used in the schemes for the installations of pipeline systems in ships
[22]
ISO/R 644:1967, Conventional signs to be used in the schemes for the installations of ventilation systems in ships
[23]
ISO/R 784:1968, Conventional signs to be used in the schemes for the installations of sanitary systems in ships
[24]
ISO/TR 8545:1984, Technical drawings — Installations — Graphical symbols for automatic control
[25]
IEC 60050-131:2002, International Electrotechnical Vocabulary — Part 131: Circuit theory
[26]
IEC 60050-151:2001, International Electrotechnical Vocabulary — Part 151: Electrical and magnetic devices
[27]
IEC 60051-1:1988, Direct acting indicating analogue electrical-measuring instruments and their accessories — Definitions and general requirements common to all parts
[28]
IEC 60617 (all parts):—1), Graphical symbols for diagrams
[29]
IEC 61082-1:1991, Preparation of documents used in electrotechnology — General requirements
[30]
IEC 61082-2:1993, Preparation of documents used in electrotechnology — Function-oriented diagrams
[31]
IEC 61082-3:1993, Preparation of documents used in electrotechnology — Connection diagrams, tables and lists
1)
Under revision.
--`,,``,`-`-`,,`,,`,`,,`---
56
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
© ISO 2005 – All rights reserved Not for Resale
--`,,``,`-`-`,,`,,`,`,,`---
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale
--`,,``,`-`-`,,`,,`,`,,`---
ISO 14617-1:2005(E)
ICS 01.080.30 Price based on 56 pages
© ISO 2005 – All rights reserved
Copyright International Organization for Standardization Reproduced by IHS under license with ISO No reproduction or networking permitted without license from IHS
Not for Resale