T-2 WCDMA Project, Slovenia
Base Station Implementation
Cable Labelling on Base Station Sites Work Instruction
Document type: Creator: Reviewer: Approver: Date approved: Function: Number/Version
DN99551773_T-2/1.0en
Work Instruction D. Cobbe G. Robinson G. Robinson 28 Sept 2007 Network Implementation Copyright © Nokia Siemens Networks
Page
28 Sept 2007
1(8)
Cable Labelling on Base Station Sites
CONTENTS 1 GENERAL ................................................................................................................................................ 3 1.1 Scope of Document........................................................................................................................ 3 1.2 Materials Required......................................................................................................................... 3 1.3 Definitions ...................................................................................................................................... 3 1.4 Document Revision History ........................................................................................................... 3 2 CABLE LABELS ....................................................................................................................................... 4 2.1 Power & Signal Cable Labels ........................................................................................................ 4 2.2 Antenna Line Cable Labels............................................................................................................ 4 3 DDF/ODF AND CIRCUIT BREAKER LABELS .............................................................................................. 6 4 CABLE LABELLING PROCEDURE ............................................................................................................... 7 4.1 Location of Antenna Cable Labels................................................................................................. 7 4.1.1 Fixing of Antenna Cable Labels...........................................................................................................7
4.2 Fixing of Self-Adhesive Cable Labels ............................................................................................ 8 4.3 Fixing of Unit Identification Labels ................................................................................................. 8
Number/Version
DN99551773_T-2/1.0en
Copyright © Nokia Siemens Networks
Page
28 Sept 2007
2(8)
Cable Labelling on Base Station Sites
1
GENERAL
1.1
Scope of Document The purpose of this document is to define the cable labels, DDF/ODF and circuit breaker labels, to be provided and installed on the T-2 Flexi Node-B base station sites in Slovenia.
1.2
Materials Required For each base station site a full set of labels is required, consisting of the label type and text given in the following Table 1 and Table 2.
1.3
Definitions AC BSS BTS DC DDF FSM GND WCDMA IU NSN ODF OU PCM RFM Rx SSD TRX Tx
1.4
Alternating Current Base Station Subsystem Base Transceiver Station Direct Current Digital Distribution Frame Flexi System Module (Flexi Node-B BTS) Ground Global System for Mobile Communications Indoor Unit (microwave radio) Nokia Siemens Networks Optical Distribution Frame Outdoor Unit (microwave radio) Pulse Code Modulation RF Module (Flexi Node-B BTS) Main Receiver Site Specific Documentation Transmitter Receiver unit Transmitter
Document Revision History DATE 28 Sept 2007
Number/Version
DN99551773_T-2/1.0en
ISSUE 1.0
AUTHOR D. Cobbe
CHECKED BY
SUMMARY OF CHANGES
G. Robinson
First Release
Copyright © Nokia Siemens Networks
Page
28 Sept 2007
3(8)
Cable Labelling on Base Station Sites
2
CABLE LABELS The NSN cable labelling system consists of two identical labels on each cable, one label on each end of the cable. The identification text on the label indicates the function of the cable and the equipment to which it is connected.
2.1
Power & Signal Cable Labels The NSN recommended cable label types for the power and signal cables are the self-adhesive wraparound paper type with printed text, for example; BRADY LASERTABTM type ELAT-18-361 and ELAT-19-361 or equivalent (see Figure 4). The cable label must be of the correct size for the cable to which it is fitted, such that the transparent film entirely covers the printed text on the label. The text on the label must be clearly printed in large bold black font of optimised size for the label. Typically two or three lines of text are printed on each label to improve visibility when attached to the cable.
2.2
Antenna Line Cable Labels The labels used on the antenna RF feeder cables are outdoor UV resistant pre-printed tag type, having black bold printed/etched characters on a yellow background, - see Figure 1. Each label consists of characters, “Sx/A/x45" indicating the sector, the antenna, and the connected port +45/-45 of the antenna. The tag labels are attached to the RF cable with black UV resistant plastic cable ties.
Size: 20mm x 70mm Font: Arial 40pt Bold Colour: Black Text on Yellow Background
RF Cable
S2/A/+45 Black UV Resistant Cable Ties
Tag Label Example
Figure 1:
Number/Version
DN99551773_T-2/1.0en
Antenna RF Cable Labels
Copyright © Nokia Siemens Networks
Page
28 Sept 2007
4(8)
Cable Labelling on Base Station Sites
Table 1: Standard Cable Labels for Flexi Node-B Base Station Sites APPLICATION
GROUND CABLES
SPECIFIC USE
TEXT
BTS1 System Module earth cable
Optical Cable to RF Module 1 OPTICAL CABLES
Optical Cable to RF Module 2
Optical Cable to RF Module 3
Flexbus RF Cable 1, IU to OU MICROWAVE RADIO Flexbus RF Cable 2, IU to OU
DC supply for System Module 1 (-48V)
DC supply for System Module 1 (GND, 0V) DC SUPPLY CABLES
DC supply for RF Module 1 (-48V)
DC supply for RF Module 2 (-48V)
DC supply for RF Module 3 (-48V)
BTS1 Interface 1 PCM E1 cable
BTS1 Interface 2 PCM E1 cable PCM CABLES BTS1 Interface 3 PCM E1 cable
BTS1 Interface 4 PCM E1 cable ALARM CABLES
Alarm cable from BTS 1 to Krone Alarm Terminal Block
BTS RF ANTENNA FEEDER CABLES
GND BTS 1 GND RFM 1 Optical RFM 1 RFM 2 Optical RFM 2 RFM 3 Optical RFM 3 Flexbus 1 Flexbus 1 Flexbus 1 Flexbus 2 Flexbus 2 Flexbus 2 BTS 1 FSM 1 -48V DC BTS 1 FSM 1 0V DC RFM 1 -48V DC RFM 1 RFM 2 -48V DC RFM 2 RFM 3 -48V DC RFM 3 BTS 1 PCM 1 IF1 BTS 1 PCM 2 IF 2 BTS 1 PCM 3 IF 3 BTS 1 PCM 4 IF 4 BTS 1 External Alarm I/P
Type
Size *
Colour
Typical Qty: Flexi Node-B
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
Self Adv.
1
Blk/Wh
2
BTS 1 Sector 1, Antenna -45° connector, feeder cable
S1/A/-45
Tag
Blk/Yel
2
BTS 1 Sector 1, Antenna +45° connector, feeder cable
S1/A/+45
Tag
Blk/Yel
2
BTS 1 Sector 2, Antenna -45° connector, feeder cable
S2/A/-45
Tag
Blk/Yel
2
BTS 1 Sector 2, Antenna +45° connector, feeder cable
S2/A/+45
Tag
Blk/Yel
2
BTS 1 Sector 3, Antenna -45° connector, feeder cable
S3/A/-45
Tag
Blk/Yel
2
BTS 1 Sector 3, Antenna +45° connector, feeder cable
S3/A/+45
Tag
Blk/Yel
2
* Note: Label Size v. Cable Diameter:Size
Brady LASERTAB
Label Size
Label Print Area Size
1
ELAT-18-361
25 x 33 mm
25 x 11 mm
<8 mm
2
ELAT-19-361
25 x 80 mm
25 x 24 mm
<20 mm
Number/Version
DN99551773_T-2/1.0en
Max Cable Diameter
Copyright © Nokia Siemens Networks
Page
28 Sept 2007
5(8)
Cable Labelling on Base Station Sites
3
DDF/ODF AND CIRCUIT BREAKER LABELS At each BTS site the following items, which are directly connected to the BTS equipment, are to be labelled:•
AC Circuit Breakers to Flexi Power Modules
•
DC Circuit Breakers to Flexi System/RF Modules
•
DDF panel for PCM E1 connections to BTS
•
ODF panel for STM-1 connections to BTS
•
Alarm Panel for BTS External Alarm connections
The NSN recommended label types are the DYMO (RhinoPRO® range thermal-transfer printer) or equivalent with tape type self-adhesive label. The self adhesive labels are to be placed on, or adjacent to, the relevant item to clearly indicate its function. The standard label set for each BTS site is given in Table 2 below.
Table 2: DDF.ODF and Circuit Breaker Labels at Flexi Node-B Base Station Sites TEXT
Ref *
Typical Qty: Flexi Node-B
BTS Ext Alarms
1
1
BTS Transmission
1
1
BTS Opt STM-1
1
1
Node-B
2
1
AC Circuit Breaker to Flexi Power/RF Module 1
RFM1
2
1
AC Circuit Breaker to Flexi Power/RF Module 2
RFM2
2
1
AC Circuit Breaker to Flexi Power/RF Module 3
RFM3
2
1
LOCATION
DESCRIPTION
BTS External Alarm Panel (Krone) label
DDF/ODF BTS Transmission DDF Panel PCM/E1 label BTS Transmission ODF Panel (STM-1) label AC/DC Circuit Breaker to Flexi Power/System Module
Circuit Breaker Labels
* Note: Label Details:Reference
Label Size
Font
Font Size
Colour
1
12 x 25 mm
Arial
24pt
Black text on white background
2
12 x 20 mm
Arial
18pt
Black text on white background
Number/Version
DN99551773_T-2/1.0en
Copyright © Nokia Siemens Networks
Page
28 Sept 2007
6(8)
Cable Labelling on Base Station Sites
4
CABLE LABELLING PROCEDURE
4.1
Location of Antenna Cable Labels Two labels are attached to each feeder cable, refer to Figure 2. For each installed feeder one label must be attached in each of the following positions:• at the top end of the feeder cable. • at the bottom end of the feeder cable. Antenna
BTS Jumper Cable Label
Feeder Cable
Label
RF External Jumper Cable
Module
Figure 2:
4.1.1
Location of Feeder Cable Labels
Fixing of Antenna Cable Labels The antenna cable labels are attached to the RF cables using two black UV resistant cable ties. White or transparent cable ties must not be used in areas exposed to sun radiation! 1. Attach one label to the each end of the feeder cable. 2. Place the labels such that they are easily visible on all cables for future identification. 3. Cut the plastic ties short and tight so that no sharp edges are remaining.
S2/A/+45
Figure 3:
Number/Version
DN99551773_T-2/1.0en
Fixing of Feeder Cable Labels
Copyright © Nokia Siemens Networks
Page
28 Sept 2007
7(8)
Cable Labelling on Base Station Sites
4.2
Fixing of Self-Adhesive Cable Labels The self-adhesive labels are fitted to the cables by simply wrapping the label around the cable, see Figure 4 below. Ensure that the correct label size is used such that the protective transparent plastic part of the label always covers the print area of the label.
Label Print Area GND BTS 1 GND
Transparent Plastic Figure 4:
4.3
Fixing of Self Adhesive Labels
Fixing of Unit Identification Labels The self adhesive labels are to be placed on, or adjacent to, the relevant item to clearly indicate its function.
Figure 5:
Number/Version
DN99551773_T-2/1.0en
Example of Circuit Breaker Labels
Copyright © Nokia Siemens Networks
Page
28 Sept 2007