5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Optical DAS Equipment
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
11/108
5/24/2018
ION-M Fiber Optical CommSc ope ION-M DAS Tra ining - slide pdf.c om
Distributed Antenna System
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
22/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Basic Components
• Optical Master Unit
• Optical Remote Unit
• Single-Mode Optical Fiber Backbone
• Antennas
• Operation & Maintenance Platform RMC600, Keyboard and Monitor
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
33/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Master
• Integral Rack Mount Controller
• Optical Transceiver
• Optional Redundant Power Supplies
• Configurable Dry Contact Alarms
• RF Distribution for Flexible Configurations – Multiple Frequency Bands – Independent Sectorization
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
44/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Master
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
5
5/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Master Front View
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
6
6/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Master Rear View
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
7 7/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
2 OTRx Subrack
• Used for Multi-Operator and/or Multi-Band systems
• Supports 2 OTRx‟s, 3 BTS Connect Modules per OTRx • BTS Connect Modules used for RF Distribution to OTRx Module • Height is 3HU
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
8 8/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
3 OTRx Subrack
• Used for single or multi operators in single band or multi band applications • Optional space for power supply • SAB can be included in this subrack • Supports 1 BTS Connect Module per OTRx • Height is 3HU
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
9 9/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
4 OTRx Subrack
• Used for single or multi operators in single or multi band applications • Optional space for power supply • Supports 1 to 4 BTS Connect Modules • Height is 3HU
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
10 10/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Optical Transceiver SMRU (OTRx)
Converts RF to optic
3 RF inputs for different frequency bands.
OPTO
Auto-leveling for optical loss up to 10 dB
• E-2000/APC optical connector. • 1310/1550 nm for downlink/uplink paths, respectively. Optical Transceiver
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
11 11/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
System Diagram: Star Configuration
MMR Remote
161988: OTRx 4-21 1800-2200 800-1000 360-500
E O
UL 1310 nm
1800-2200 800-1000 360-500
1550 nm
O E
DL
MMR Remote
• One OTRx for each Remote Unit
161988: OTRx 4-21 1800-2200 800-1000 360-500
E O
UL 1310 nm
1800-2200 800-1000 360-500
• Separate optical fiber for each Remote Unit
1550 nm
O E
• Standard system configuration
DL
MMR Remote
161988: OTRx 4-21 1800-2200 800-1000 360-500
E O
UL 1310 nm
1800-2200 800-1000 360-500
1550 nm
O E
DL
MMR Remote
161988: OTRx 4-21 1800-2200 800-1000 360-500
E O
UL 1310 nm
1800-2200 800-1000 360-500
1550 nm
O E
DL
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
12 12/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Mini Master Controller (MMC plus)
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
13 13/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Display and Keyboard Equipment
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
14 14/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Leveling Adapter
• The front panel RF connectors provide access to the DL and UL RF signals that would be input to the OTRx. • Input signal levels can be adjusted prior to the OTRx and measured through the leveling adapter. • The leveling adapter is used in place of the OTRx to aid in leveling the downlink path. • The front panel interface connectors are SMA-Female.
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
15 15/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Duplexers
7612767-00
Duplexer Passive 698-716 776-787 728-757
7597010-00
Duplexer Passive 806-824 851-869
7597012-00
Duplexer Passive 824-849 869-894
7597020-00
Duplexer Passive 880-915 925-960
7597024-00
Duplexer Passive 1850-1915 1930-1995
7543460-00
Duplexer Passive 1710-1755 2110-2155
Mounted in the rear of the subrack.
TX TX/RX RX
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
16 16/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Duplexer Unit
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
17 17/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Indoor Racks 24HU, 38HU, 47HU • 24 HU – H x W x D: 1260 x 605 x 700 mm – (50 x23.8 x 27.6”)
– Weight: 82 kg, 180 lbs • 38 HU – H x W x D: 1860 x 605 x 700 mm – (73 x2 3.8 x 27.6”) – Weight: 109 kg, 240 lbs
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
18 18/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Rack Fan Sets
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
19 19/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Indoor Rack Installation
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
20 20/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Indoor Rack Installation
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
21 21/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Indoor Rack Installation
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
22 22/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Indoor Rack Anchorage Kit
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
23 23/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Outdoor Rack
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
24 24/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Outdoor Rack Options
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
25 25/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Rack Power Supply Unit
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
26 26/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Rack 4 Power Supply Unit
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
27 27/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Rack 8 Power Supply Unit
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
28 28/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
8 Power Supply Unit
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
29 29/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Power Supply Unit (PSU)
• 7159468: 85 to 264 VAC Input • 7159467: 36 to 76 VDC Input U1
+ -
• Output is 12VDC, 150W • One PSU supports up to 7 OTRx‟s
U1 Test
• N+1 Redundancy is provided when using one PSU more than required
Power Supply
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
30 30/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Power Supply Subrack – 4 PSU
• 7163420: Supports 1 to 4 AC PSU‟s and RAB • 7163421: Supports 1 to 4 DC PSU‟s and RAB
• Supports 1 to 4 OTRx subracks • Height is 3 HU
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
31 31/108
5/24/2018
Power Supply Subrack – 8 PSU
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• 7163765: Supports 1 to 8 DC PSU‟s and RAB • Supports 1 to 8 OTRx subracks • 7163764: Supports 1 to 8 AC PSU‟s and RAB • Height is 6HU
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
32 32/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Indoor Rack Power Cable Installation
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
33 33/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Rack AC Power Terminal Block Connections
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
34 34/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Rack DC Power Terminal Block Connections
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
35
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
35/108
ION-M Master Cable Routing
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
36
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
36/108
ION-M Outdoor Rack Power Cable Installation
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
37
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
37/108
ION-M Multi Rack Interconnect Cable Installation
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
38
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
38/108
ION-M Installation Electrical Installation
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
39
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
39/108
ION-M Rack Power Loading
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
40
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
40/108
5/24/2018
RF Combining Section
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
41
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
41/108
5/24/2018
4-Way Combiners
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• ID 7161269-00 : 698-960 MHz 1
• ID 7160615 : 1710-1990 MHz • ID 7160614 : 1920-2170 MHz
2
3
• Combines four input into a common output. Typically a duplexer is required to separate UL/DL. • The signal level into each port can be adjusted with a variable attenuator 0-10 dB typically. • The front panel interface connectors are SMA-Female • Max. input power per port: 27.5dBm
4
RF Probe 4-Way Combiner
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
42
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
42/108
4-Way Splitters
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• Splits a single input to four outputs. Typically a duplexer is required to separate UL/DL.
1
• The front panel interface connector is SMAFemale
IN
2
7612781-01 Splitter Rear Mount 4-way 698-960 6.5dB IL 3
4-way Splitter with Att. d B d B
4 160641 4-Way Splitter
7615789-00 Splitter Rear Mount 4-way 1710-2170 6.5dB IL 7614494-00 Splitter 3HU 4-way 698-960, 10-20 dB IL 7163801
Splitter 3HU 4-way 1710-2170, 12-21 dB IL
7618755
Front Panel Kit for front mounting
d B d B
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
43
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
43/108
5/24/2018
BTS Connect 2 Port 698-960 MHz
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ID# 7614493-00
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
44
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
44/108
BTS Connect 3 Port 1710-2170 MHz
5/24/2018
ID# 7164621
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
45
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
45/108
BTS Connect 4 Port 698-960,1700-2200 MHz
5/24/2018
ID# 7546702-02
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
46
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
46/108
BTS Connect Attenuators
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
47
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
47/108
Intelligent Point of Interface (i-POI)
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
UL1 UL2 UL1,2
UL1,2
UL DIV1,2
UL DIV1,2
DL/ UL1
DL/ UL2
DL 1,2 DL 1,2
DL1,2 DL1,2
•
Support of 2 independent BTS sources
•
Termination loads for 2 x 46 dBm
•
Un-duplexing of in-coming signal
•
Measurement of RF-power from BTS and to BTS
•
Signal combining
•
Support of duplexed and non-duplexed signal
•
Support of UL diversity
•
Support of E911 call detection
•
Test-tone generator for easy leveling and trouble-shooting
UL1 DIV UL2 DIV E911-UL1 E911-UL2 (DIV) E911 Sync
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
48
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
48/108
Intelligent Point of Interface (i-POI)
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Subrack address display
DC main input & interface to system controller
with subrack alarm status
via backplane connectors
LMT Interface
External Alarms 2 software defined inputs 2 software defined output 1 Summary-alarm
Up to 8 independent POI modules
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
49
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
49/108
Intelligent Point of Interface (i-POI)
5/24/2018
Active Version
CommSc ope ION-M DAS Tra ining - slide pdf.c om
•
46 dBm input power per BTS port (2 ports)
•
Supports duplexed, non-duplexed & uplink diversity BTS inputs
•
-153 dBc PIM @ 2 x 20 Watts
•
Up to 8 POI modules (sectors) per subrack
• Automatic level control over a 60 dB range in 0.5 dB increments •
Integrated tone generator for end-to-end signal leveling
•
Real time power measurement & display
•
End-to-end front panel fault indication (SW dependant)
•
Can be used with third party DAS systems (internal web server) and fully integrated to the CommScope DAS solution
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
50
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
50/108
Rack Alarm Board (RAB)
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• Collects and provides alarm outputs for Power Supply Units DOOR
PSU/FAN
PSU1
PWR
(PSU) • Collects and provides alarm outputs for door and cabinet fan
• Alarm outputs would be connected to Rack Master Controller (RMC)
PSU2
PSU3
• RAB would be mounted in PSU subrack
PSU4
PSU5
PSU6
PSU7
PSU8
RAB
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
51
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
51/108
ION-M Remote- M Cabinet
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Remote is available in various band configuration. Reference specific remote datasheet for power consumption.
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
52
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
52/108
ION-M Remote- M Cabinet
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
53
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
53/108
ION-M Remote- M Cabinet Connections
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
54
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
54/108
ION-M Remote - Grounding
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
55
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
55/108
ION-M Remote - Electrical Connections
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
56
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
56/108
ION-M Remote - Electrical Connections
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
57
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
57/108
ION-M Remote - Antenna Connections
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
58
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
58/108
ION-M Remote – Optical Fiber Connection
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
59
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
59/108
ION-M Remote – Optical Fiber Connection
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
60
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
60/108
ION-M System Fiber Optics Specifications 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• Only One Optical Fiber Required – Integral WDM Combines Uplink and Downlink Signals on a Common Fiber – Downlink at 1310 nm – Uplink at 1550 nm – 10 dB Optical Link Budget – Optical Fiber Loss ~0.4 dB/km (1310 nm) – 10 dB optical budget for all RF parameters implies 25 km(15 miles) fiber length
• Low Profile E2000-APC Connector – Integral Dust Cover – Easy Insertion and Snap Connection
1310 nm
1550 nm
(2nd window)
(3rd window)
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
61
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
61/108
ION-M Remote Mechanical Installation 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
62
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
62/108
ION-M Remote Mechanical Installation 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
63
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
63/108
ION-M Remote Mechanical Installation 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
64
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
64/108
ION-M Remote Mechanical Installation- Wall Mounting 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
65
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
65/108
ION-M Remote Mechanical Installation - Pole Mounting 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
66
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
66/108
ION-M Remote Mechanical Installation - Pole Mounting 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
67
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
67/108
ION-M Remote Status LED 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
68
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
68/108
ION-M Remote- ML Cabinet 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Reference specific remote datasheet for power consumption.
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
69
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
69/108
ION-M Remote- W Cabinet 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
ION-M Remote is available in various band configuration. Reference specific remote datasheet for power consumption.
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
70
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
70/108
ION-M Single Band Remote Block Diagram 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Antenna
Duplexer O Optical Input
PA
E
WDM O
MicroController
LNA
E
Power Supply
Heat Exchanger
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
71
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
71/108
Dual Band Remote Block Diagram 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Antenna
PA Duplexer
O
Optical Input
E
PA
WDM
O
LNA
LNA
E
MicroController
Power Supply
Heat Exchanger
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
72
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
72/108
ION-M17HP/19P Remote Specifications
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
73
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
73/108
ION-M DAS System Diagram 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Antenna Master Subrack
Remote Unit
B
External UL POI
C
Subrack UL POI
o
e
e
o
A
o
RX
BTS
e
D
o
TX
ION-M system gain specified from point A to point B
e External DL POI
Subrack DL POI
Antenna
Remote Unit
o
e
e
o
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
74
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
74/108
ION-M DAS System Diagram 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
75
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
75/108
TMO LIT HUB Plumbing 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
76
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
76/108
Basic Link Budget LIT 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
77
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
77/108
ION-M DAS System Diagram 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
78
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
78/108
ION-M 700 LTE MIMO/850/1900 design 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
79
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
79/108
ION M Remote Active Cooling 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• Small Form Factor
• Fans Are Easily Replaced • Fan Speed Varies – Fan Speed Increases as Heat sink Temperature Rises – Fan Speed Decreases, or Stops, when Heat sink Temperature is Low
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
80
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
80/108
ION-M Remote Passive Cooling 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• Insensitive to Dust
• No Acoustic Noise Emission • Useful for Tunnel Applications
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
81
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
81/108
ION M Remote Accessories 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• Fan Protection Cover – Additional Environment Protection
• Mounting Brackets – Wall Mount Option – Pole Mount Option
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
82
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
82/108
ION-M Remote Overcoat Housing 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• Offers Protection – Environment – Vandalism
• Reduces Acoustical Noise • May be Painted for Specific Requirements
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
83
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
ION-M Remote Master Controller Software Login
83/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
At first login, enter the Username (owner ), enter the default password (Apwd4own)> (case-sensitive, no blanks allowed). Changing the password is described in chapter 3.4.5 Owner Settings.
Microsoft Windows Login username: mikom or andrew password: mikom or andrew PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
84
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
ION-M Software
84/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
85
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
85/108
ION M Software 5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
H o m e : leads back to the home page; L o g o u t : to log out of the system.
The Tree View displays the current system topology determined during auto-setup in tree format. C u r r e n t A l a r m S t at u s shows the number of current alarms in order of their severities.
Alarm severities are also indicated by a color code. The Home frame shows the current software version as well as supplementary information on the software of thefor Master Controller. Tree View – the menus available the selected unit.When a unit is selected from the
The main frame provides a system overview in graphic form. The three main menus –S u p e r v i s i o n , C o n f i g u r a t i o n , and Ma i n te n a n ce – are the same for all unit types; only the available submenus vary depending on the type of unit.
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
86
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
ION-M Tree View
86/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• MC=Master Controller 1 per system (master unit including RMC600 & MMC+)
• SRMU=Subrack master unit (MU OTRX)up to ~50 per controller
• RU=Remote unit 1 per SRMU
• SAB=System alarmboard 1 per system (option)
• RAB=Rack alarmboard 1 per rack (option)
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
87
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
SRMU (OTRx) Menu
87/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
88
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
ION-M Remote (RU) Menu
88/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
89
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
HW/RF Parameters
89/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
90
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
RAB Menu (Rack Alarm Board)
90/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• The RAB collects alarms from up to 8 PSUs, two fan sets, one door alarm and mains-failure (if an UPS is connected).
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
91
SAB Menu (System Alarmboard )
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
91/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
92
Active Alarms and History
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
92/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• This screen shows all the alarms that are active in the whole system. • These alarm messages will also be displayed in the „Alarm History ‟.
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
93
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
Handling of ‘Alarms’
93/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• MMC+ Master Controller software will show all existing alarms in the system • All alarms can be resolved with a „process of elimination‟ and respective units can be replaced/repaired as needed
Click on to get summary
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
94
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
Remote Unit Alarm Indication
94/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
•
Following alarms are indicated from LED at connector flange:
•
LED off:
No power
» Bad power supply » No VAC input
•
LED green:
No alarm
•
LED yellow:
Alarms not directly related to RU » External alarms » Optical RX alarm » all ALC alarms
•
LED red:
Alarms directly related to RU » Power alarms 12 & 28 V » Temperature » Fan » I2C Bus » Optical TX alarm » Amplifier “power down“
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
95
RU Alarms
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
95/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• If showing alarm at RU site; check with HUB or NOC to see what the alarm is reported in Master Controller software. – ALC Alarm: Check RF input level, Check RU ALC settings. – PA Alarm: Check RF input level, Check amplifier software configuration, Reset amplifier via software, hard reset unit (disconnect power). – Temperature Alarm: Check if fans are working, ensure proper airflow (airdeflectors), power down unit to alleviate further over-heating. – Unit Unavailable: Check fiber, try spare fiber.
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
96
SRMU Alarms
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
96/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
•Flashing “E” No connection with RU: Check fiber, RU power, and controller software for alarm message. •Flashing “I”
I2C
Bus Error: Re-seat card in subrack, replace OTRx.
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
97
Alarms and Troubleshooting
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
97/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• SRMU Alarms – Fiber optic RX/TX alarm – Bus I2C failure – System temperature – Fiber optic DL/UL current – Unit unavailable
A detailed list of all alarms is provided in the User Manual for Optical Master unit.
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
98
Cannot Connect to the MMC+
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
98/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• What is the status light telling you?
• Do you have a network connection (LAN) on your computer? • What is the IP address that has been assigned to your computer?
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
99
Cannot connect to the MMC+
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
99/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• If you have a network connection established with your computer try NetMeeting. • NetMeeting allows you to controll the MMC+ desktop. Start
Run conf
• Username = andrew Password = andrew • NetMeeting not included with Windows 7 (Windows XP Virtual Mode)
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
100
Cannot connect to the MMC+
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
100/108
5/24/2018
• MMC+ is a Windows2000 PC.
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• Controller services run on the PC to perform many software functions. • Sometimes these services will not get started correctly and not allow web access to the ION-M software.
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
101
ION-M Master Unit Installation
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
101/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
The Master Unit is CoLocated with Base Stations
Easy Accessible
Easy Maintenance
Decrease Costs
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
102
ION-M Remote Installation
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
102/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Invisible Mounting
RF Portion Below Ground
Cooling Portion Integrated in Lower Portion of Waste Basket
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
103
ION-M Remote Installation
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
103/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
104
ION-M Remote Installation
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
104/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Invisible Mounting
Installed inside the light pole
Cooling accomplished inside pole
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
105
ION-M Remote Installation
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
105/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Minimal Visual Impact
Residential Setting
Standard wooden utility pole
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
106
CommScope TECHNICAL SUPPORT
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
106/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
• WWW.COMMSCOPE.COM – http://www.commscope.com/andrew/eng/product/cov_cap/index.html
• CommScope Wireless Solutions - Joliet, IL 60433 Customer Support Center 800-255-1479
• CommScope Distributed Coverage and Capacity Solutions Technical Support - Garner, NC 27529 888-297-6433
PRIVATE AND CONFIDENTIAL © 2012 CommScope, Inc
107
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining
107/108
5/24/2018
CommSc ope ION-M DAS Tra ining - slide pdf.c om
Thank you!
http://slide pdf.c om/re a de r/full/c ommsc ope -ion-m-da s-tra ining