Flow Con Conttro roll – Baker Baker Plugs Plugs Standard and Surset
Europe Learning Centre WCP Train Training ing Schlumberger
Presentation Objectives Ÿ
Famililiar Fam iarization ization with with Baker flow flow cont ontrol rol equ equipm ipment ent
Ÿ
Standard and Surset Landing Nipple and lock specifications
Ÿ
Baker Probes, shanks and prongs
Ÿ
Equalization devices and their associated running/pulling tools
Ÿ
Running Run ning procedures procedures
Ÿ
Pulling proc procedu edures res
Ÿ
Baker Nomenclature
a er – an ng n pp es Two T wo Ba Bak ker sy syst ste ems – St Sta andard and Su Surrse sett
Ÿ
Firstt we will Firs will conc oncent entrate rate on Baker standard equ equipm ipment ent
Ÿ
Th T here are two st sta andard la lan ndin ing g nip ipp ple less
Ÿ
Both are nogo landing nipples nipples
Ÿ
Both have have a profi profile, le, seal seal bore and nogo
Ÿ
Even though Even though they they have have nogo shoulders shoulders Baker have have a sel selec ective tive system due to the lock type Ÿ
a er
an ng n pp es
Top nogo la To lan ndin ing g nip ipp ple – the nogo is above the seal bore Ÿ
ID of the nipple nipple is is th the e seal bore dimension dimension
Ÿ
Willll acc Wi accep eptt th the e following locks
Ÿ
M ,G ,G,F ,F and and W S – select selectiv ive e du due to to lock All L Sliding Sliding side doors have have an F nipp nipple le profile profile
a er
an ng n pp es
Bottomnog nogo o landing landing nipple nipple – th the e nogo nogo is below the th e seal bore Ÿ
ID of the nipple nipple is is the dimensi dimension on of the nogo nogo shoulder, small smaller er than seal bore Ÿ
Willll acc Wi accep eptt th the e following locks
Ÿ
Z,R,E and and K Always installed below an F nipple of the same nominal size
ow ng an non ow ng app c at ons Equalizing Equali zing assembli assemblies es can c an be added added to all the standard locks loc ks to form form plugs Ÿ
Gauge carr Gauge carries ies (bom (bomb b hangers hangers)) can can be added to two two loc locks ks to be be used in flowing flowing app applilic cations Ÿ
W loc lock k in the the top nogo nogo F nipple nipple
Ÿ
Z lo loc ck in the bottom nogo R nipple nipple
Ÿ
V packing packing are attac attached hed to to Equali Equalizing zing dev devic ices es
Ÿ
tan ar
Ÿ
a er omenc ature
Abov bove e is is show shown n the the title title given to a stan standard dard Baker Baker plug
From th the e title th the e correc correctt nipple, nipple, loc lock k and equali equalizing zing assem ass embly bly/f /flow low cont ontrol rol devic device e can can be be selecte selected d Ÿ
qua z ng ev c es Th T hree types use sed d in st sta andard Ba Bak ker plu lug gs
Ÿ
H – Prong ty type, prong run and set after plug bod body y is set. 2 runs to set and 2 runs to pull Ÿ
G – Prong ty type, prong prong run with plug bod body y. 1 run to to set set and 2 runs to pull Ÿ
Ÿ
R – M elon type, type, 1 run to to set set and and 1 run to to pull pull
qua z ng ev c es
ro es,
an s an
rongs
Stan tandard dard Baker Baker require add additio itions ns to run and pull pull th the e devices Ÿ
To run the device a Sh To Sha ank is attach che ed to the runnin ing g tool Ÿ
To T o pull the device a Pro Prob be is attach che ed to the pull llin ing g tool
Ÿ
Ÿ
For equalization Prongs are used
ro es,
an s an
rongs
Similar probes can have modifi odific cations, e.g. Ÿ
A & AC AC probes probes cann cannot ot be be used for the same operation, an AC AC probe probe has no internal thread th read to acc accept a prong Ÿ
An M1 Probe has a telltale shear pin where where an M prob probe e has not. Ÿ
unn ng oo s C1 – used to to run W, Z, Z, G,R G,R and and S locks, loc ks, can can be be used to to run FB FB & RB stand tanding ing valves Ÿ
E Selective Selective – used to to run run S selective selective locks loc ks with with all th the e dogs dogs retracted Ÿ
G Selec Selecttive – used to run run S selectiv selective e locks loc ks with with up fac facing ing dogs dogs trail trailing ing Ÿ
C1 can be used to run run the the S selec sel ectiv tive e lock loc k with with th the e up facing facing dog dogss trailing Ÿ
unn ng oo s Bake akerr M pu pulllling ing tool tool used to run and and pull pull several locks Ÿ
E, M (loc (locks) ks) and and B (safety valve) loc locks ks can can be run using the the M pulli pulling ng tool tool Ÿ
With this this tool th the e probe is also also used to set the th e devic device e Ÿ
E.g. when an M1 E.g. M 1 probe is used to set devic dev ices, es, the probe probe has a shear shear pin to indicate indic ate correc orrectt sett setting ing Ÿ
a er o t et runn ng too Ÿ
Image shows RZB
Soft set tool Soft tool allow allowss for set settin ting g with without out jarr jarring ing as no pins are she sheared ared Ÿ
Preven revents ts jarri jarring ng forces forces dam damaging aging the the gaug gauges es or disturbing the recording device Ÿ
Ÿ
NOTE – no pac packin king gs are fit fitted to dev devic ice e
a er W loc lock k and and G equalizing equalizing dev devic ice e
Ÿ
Plug – ho hold ld pressure fromabo abov ve and and below below
Ÿ
Prong run wi with th plug bod body y – 1 run to to set
Ÿ
Collet and collet bowl prevent prong moving down
Ÿ
Shear pin pin (brass) (brass) prevents prevents the prong moving moving up
Ÿ
Run on C1 C1 – 1 x Alum Aluminum inum (prong) 2 x Bras Brasss (body (body))
Ÿ
Bras rasss pins pins through body have 2 options
Ÿ
a er
– sett ng pu ng
Depends on C1 pinning, best to pin allowing for overov er-pu pullll,, pins pins below fis fishin hing g nec neck k Ÿ
RIH – set down RIH down in nipple, nipple, jar down to land on nog nogo, o, dogss loc dog lock k into into profile, profile, over over pull pull to confirm confirm Ÿ
J ar up to sh she ear Br Bra ass pin inss belo low w FN on body, C1 moves up pulling prong to sealing position, then aluminum pin through prong shears Ÿ
Prong loc lock k in sealing posi position tion by coll ollet et and coll ollet et bowl Ÿ
a er
– sett ng pu ng
To pull device To ice,, pull prong usi sin ng SB/ SB/JJ DC to equali lizze, B prob probe e must must be be attac attache hed d to to SB SB/J DC to pull pull plug body bod y, B probe coll collapses apses th the e dogs dogs when eng engaging aging FN FN Ÿ
Ÿ
W2 lock has different dogs, different pivot position
Small aller er sized sized G equ equali alizing zing assem assemblies blies hav have e two pins through the collet bowl sleeve Ÿ
SB or J DC must must be be used to to pull pull de dev vic ice e as skirt may may contact body preventing shearing off Ÿ
a er Ÿ
Bottom nogo option for R nipples
Ÿ
Same function as FWG
Ÿ
Sam ame e running/pulli running/pulling ng proc procedu edures res as FWG
Bec ecause ause of FN ang angle le and pulli pulling ng to tool ol OD dif difference ference Otis pu pulllling ing tool tool should be us used Ÿ
Ÿ
Ensure equalization before latching lock
a er Ÿ
Plug does not have have a nogo shou shoulder lder
Can be run using either a C1, G selective or E selective running tools Ÿ
Shan hank k holds dogs in run running ning posi position, tion, prong holds melon in equ equali alizing zing pos position ition Ÿ
When pulling device, Kobe plug on equalizing body is brok broken en to to allow allow pressure equali equalizzation Ÿ
a er
sett ng pu ng
Run using an A shank and pulled using an AC probe with an equali equalizing zing prong prong attac attached hed Ÿ
C1 with a locator ring to find the F nipple nogo shoulder Ÿ
G selective tool holds the down facing dogs retracted Ÿ
Upon location of nipple pick up, up facing dogs locate the profile, half jar up shears C1 pins and releases releas es down facing facing dogs dogs lockin locking g dev devic ice e in nipple nipple Ÿ
a er
sett ng pu ng
To pull the device To ice,, an A or AC probe must be use sed d attached to the pulling tool Ÿ
Th T he probe rele lea ase sess the up facin cing g dogs
Ÿ
After equalization, jar up or over pull to release the device Ÿ
E – selec selecttiv ive e tool tool holds holds all dog dogss retrac retractted ed,, allow allowss for passing pass ing of sam same e sized sized F nipples nipples,, pins on on running running tool tool shear to release release the upp upper er dogs and setting setting is as per on previous tools Ÿ
oc c art
tan ar
a er summary
Two nip Two ipp ple less use sed d, F – top nogo, R – bottom nogo To T op nogo lo lock ckss – M ,G,F,S and W Bottom nogo loc locks ks Z,R, Z,R, E and K Th T hree equali lizzin ing g device icess H and G (prong) R (melo lon n) C1,, G and C1 and E selec selective tive running running tools tools used on S loc locks ks C1 running tool on W and Z locks M pu pulllling ing tool tool used to run run and and pull pull E and M loc locks ks Probes, Shanks Shanks and Prong rongss W and Z loc locks ks used used on gauge gauge hanger hanger operations Soft set set tool tool used to set gauges gauges in in F and and R nipples nipples Gauge Gaug e hanger adapter known known as B attac attachm hment ent
Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ
a er urs rse et equ pment Standard equipment equipment did not meet meet pressur pressure e rating rating needs of the industry Ÿ
New system need needed ed henc hence e Surset Surset was was developed
Ÿ
New nipples dev developed eloped that that inc included luded press pressure ure ratings
Ÿ
Retain F and R nogo positioning
Ÿ
A <10 <10K K, H 1010-15K and V >1 >15K
Ÿ
New nipples becam became e AF, AF, HF, HF, VF, AR, HR and VR VR
Ÿ
a er urs rse et equ pment Locks made to match nipples hence AF went into an AF nipple, nipple, of VR lock lock matc matched hed a VR nipple nipple Ÿ
Only two equalizing equalizing de dev vic ices es use H – pron prong g and M – melon (sometimes known as R) Ÿ
Ÿ
One running tool (model A) to run all locks
Ÿ
Can be pulled with Baker M (Otis GS)
a er urset n pp es an
oc s
•Top nogo nipples AF, HF and VF
•Top nogo loc locks ks AF, AF, HF and VF
•Bottom nogo nipples AR, HR and VR
•Bottom nogo locks AR, HR and VR
Baker Surs Surset et AFH AFH,, HFH, HFH, VFH VFH (ARH,HRH, (ARH,HRH, VRH) VRH) •AF lock with H (prong) equalizing device
•Two runs to set, two runs to pull
•Prong sized sized to prevent debris entering plug (extend (extended ed FN should be used) used) • •M odel A R/T with with D probe probe used to run plug
Bak aker er Surset Surset AFM , HFM , VF VFM M (ARM , HRM ,V ,VR RM ) •One run to set and one run to pull
•M ust be be used in clean clean wells wells
•Sam ame e runn runniing and pull pulling ing tools tools as top nogo equipment
•Snap ring to secure melon and lock in set positions
Bak aker er Surset S urset Mode M odell A run running ning too tooll (D prob probe) e) •If device is not set correctly, running tool does not release plug
•Brass shear screws sc rews for set settin ting g of plug plug
•Brass shear pin to allow for over pull and shearing off
•Snap ring to hold tool in in release release posi position tion
a er urset - runn ng an sett ng
a er urset – sett ng pu ng devic ice e is locat located ed correctly the hen n the • If dev running tool will release from the plug •Snap ring in running tool holds retainer FN dogs dogs in in release posi position tion •Snap ring ring holds exp expander ander mandrel mandrel in set set position •To pull device use either Baker M or Otis GS - en ensure sure eq equa ualizat lization ion be before fore pulling
a er urse rsett su sum mmar ary y • Locks fit in matched landing nipples i.e, AF into AF •Three pressure pressure ratings av avail ailable able •Tw Two o equal equalizing izing assem assemblies blies in use H and M (R (R)) •M odel A runn running ing tool with with D probe probe to set •Pulled with either a Baker M or Otis GS •T2 type standing valve adapter used i.e. AFT2