kriteria penggunaan waterproofing pada bangunanFull description
WaterproofingFull description
WaterproofingFull description
ITP
KP-00+++-CQ712-G0011_Rev.A_ITP for for Cathodic Protection ( CP )Description complète
KP-00+++-CQ712-G0011_Rev.A_ITP for for Cathodic Protection ( CP )Full description
ITPFull description
Some people don't know what is ITP. With this sample, I hope everyone clear about ITP.
Descripción: Mobile Scraper Traps Inspection and Test Plan NAWCPF-MSBI-NCPF-360-QC-ITP-84003_Rev C03
Full description
Inspection Test Plan(ITP) Painting WorksDescrição completa
metode pengujian integral waterproofingDeskripsi lengkap
INSPECTION & TEST PLAN REF. NO NO.: ITP-6005-041
PROJECT: RUWAIS HOUSING COMPLEX EXPANSION – PHASE III CONSTRUCTION OF MARRIED STAFF ACCOMMODATION FACILITIES AND RELATED INFRASTRUCTURE PACKAGE IV PROJECT NO. 6005, AGREEMENT NO.116005C1
REV. NO.:
00
DATE :27/06/2010 Page 1 of 2
ACTIVITY: ROOF WATERPROOFING AREA: ALL BUILDINGS LEVEL: N/A
ITEM NO.
DESCRIPTION
SPECIFICATION/CRITERIA
INSPECTION & ACCEPTANCE ITL CONT. ADNOC
REMARKS / REPORT NO.
01- Material.
Approved Material for water water proofing proofing
Civil Specification Vol.4 Sec. 07122 Clause 2.1
H
H
MVR
02- Project Condition.
Comply with manufacturer's recommendations
Civil Specification Vol.4 Sec. 07122 & MS6005-041 REV 00
H
S
Method Statement.
03- Preparation of Substrates.
Substrate shall be clear of foreign material and oil/greasy substance, uneven surface and it should be smooth
Civil Specification Vol.4 Sec. 07122 Clause 2.1
H
H
I T R
Material should delivered on site un open bearing the manufacturers brand name and description of content, polythene, membrane, flashing and adhesive adhesive and shall be stored in dry area, protection board place flat above above the ground surface.
Civil Specification Vol.4 Sec. 07122
W
S
As per manufacture recommendation to ensure full compliance as required in specification Civil Specification Vol.4 Sec. 07122
W
W
a) Surface preparation and cleaning
MS-6005-041 REV 00
H
W
b) Light Weight Foam concrete
MS-6005-041 REV 00
H
H
c) Waterproofing Primer DUPRIME as per manufacturer recommendations
MS-6005-041 REV 00
H
W
d) Waterproofing membrane 4mm thick
MS-6005-041 REV 00
H
H
H
W
H
H
04- Product Delivery and storage
05- Method of Application.
06. APPLICATION
As per manufacture method statement and manufacturer recommendations.
e) Geo textile Layer as per approved shop drawings. f)Insulation board
PROJECT: RUWAIS HOUSING COMPLEX EXPANSION – PHASE III CONSTRUCTION OF MARRIED STAFF ACCOMMODATION FACILITIES AND RELATED INFRASTRUCTURE PACKAGE IV PROJECT NO. 6005, AGREEMENT NO.116005C1
INSPECTION & TEST PLAN REF. NO.: ITP-6005-041 REV. NO.:
00
DATE :27/06/2010 Page 2 of 2
ACTIVITY: ROOF WATERPROOFING AREA: ALL BUILDINGS LEVEL: N/A
ITEM NO.
DESCRIPTION
SPECIFICATION/CRITERIA
g) Geo textiles Layer and aluminum flashing at the edges with flexible sealant h) Precast Concrete tiles 60X60X5CM and 25mm Washed aggregate LEGEND :
H - HOLD FOR INSPECTION
Associated Constructions & Investments Co. LLC
MS-6005-041 REV 00
H
H
MS-6005-041 REV 00
H
H
REMARKS / REPORT NO.
ITR
W - WITNESS INSPECTION
MAIN CONTRACTOR :
INSPECTION & ACCEPTANCE ITL CONT. ADNOC
S - SURVEILLANCE INSPECTION MAIN CONTRACTOR APPROVAL