CATV OUTDOOR AMPLIFIER Plug-in Module Series, ALSC Modules
ALSC-0 Automatic Level Level & Slope Control Control
ALSC-04 Automatic Level Level & Slope Control Control
Descriptions : The ALSC-0 & ALSC-04 modules are operated by broadband detecting technology to control output level. The & ALSC-0 & ALSC-04 are designed with two functional devices which offer an easy way for adjustment. a. Adjusting Trimmer Trimmer - To adjust the control point to a proper level position. b. High/Low Switch Switch - It means user can simply toggle the switch to position high high or low depending on different channel loading. The ALSC-04 module is only for MT-3512, MT-3532, MT-3202 and series amplifier. The ALSC-0 module is only for LE-3010 series amplifier
Specifications : Model Number Frequency Range Controller Operative Set Point Range Temp. Drift Ref. To Set point Controller Error Control Range Reset Time Supply Voltage Current Consumption Temp. Range Impedance Dimensions Net Weight
ALSC -04
MHz dBuV dBc dB/dB dB sec V mA
mm g
ALSC -0
47 ~ 862 MHz Lo Level : 86 ~ 98 Hi Level : 96 ~ 106 0.005 0.02 4 2 15 5% 60 20% -20 ~ +70 75 65.2(L) x 21.2(W) x 34.5(H) 50.2 x 15.2 x 34.3 18
Specifications are subject to change without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan ZINWELL Corporation
CATV OUTDOOR AMPLIFIER Plug-in Module Series, ALSC Modules
ALSC-0 Automatic Level Level & Slope Control Control
ALSC-04 Automatic Level Level & Slope Control Control
Descriptions : The ALSC-0 & ALSC-04 modules are operated by broadband detecting technology to control output level. The & ALSC-0 & ALSC-04 are designed with two functional devices which offer an easy way for adjustment. a. Adjusting Trimmer Trimmer - To adjust the control point to a proper level position. b. High/Low Switch Switch - It means user can simply toggle the switch to position high high or low depending on different channel loading. The ALSC-04 module is only for MT-3512, MT-3532, MT-3202 and series amplifier. The ALSC-0 module is only for LE-3010 series amplifier
Specifications : Model Number Frequency Range Controller Operative Set Point Range Temp. Drift Ref. To Set point Controller Error Control Range Reset Time Supply Voltage Current Consumption Temp. Range Impedance Dimensions Net Weight
ALSC -04
MHz dBuV dBc dB/dB dB sec V mA
mm g
ALSC -0
47 ~ 862 MHz Lo Level : 86 ~ 98 Hi Level : 96 ~ 106 0.005 0.02 4 2 15 5% 60 20% -20 ~ +70 75 65.2(L) x 21.2(W) x 34.5(H) 50.2 x 15.2 x 34.3 18
Specifications are subject to change without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan ZINWELL Corporation
CATV / MATV PASSIVE DEVICES 862 MHz, 2 Outputs + Built-in Diplexer Isolated Surge Protector
TAP 10dB OUT OUT 70~862MHz
IN 5~862MHz
H L
H L
DATA 24~55MHz (Revers,Band) 70~862MHz (Forward,Band)
ART-D2455-10 ART-D2455 -10
Features : ART-D2455-10 features the built-in diplexer to eliminate harmonic distortion for cable modern application; ART ART-D2455-10 with extra high pass filter to eliminate ingress noise. Low insertion loss to RF signals ADC-3 aluminum alloy die-casting housing with powder coating Special "F" connector for waterproof and good contact Good Shielding
Specifications : Description
Freq. Range (MHz) IN - OUT
In Insertion Loss IN - DATA Return Loss Isolation
IN , OUT , DATA OUT - DATA
Specifications
5 ~ 55
40 dB typ. 30 dB min.
70 ~ 770
2 dB typ. 3.2 dB max.
770 ~ 862
2 dB typ. 3.5 dB max.
5 ~ 12
40 dB typ. 30 dB min.
24 ~ 55
1.5 dB typ. 2.5 dB max.
70 70 ~ 862
8.5 dB typ. 10 dB max.
24 ~ 55
14 dB min.
70 70 ~ 862
10 dB min.
5 ~ 55
30 dB min.
70 70 ~ 862
18 dB min.
High Voltage Protect Fr From input inner conductor to output inner conductor
1KV/ 10mA
Fr From input inner conductor to output outer conductor
during 1 minute
From input outer conductor to output inner conductor From input outer conductor to output outer conductor Impedance Waterproof Condition
75 2
1.0kg/cm
Ne Net Weight Specifications are subject to change without notice. Special specifications can be specified by order.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan ZINWELL Corporation
60seconds
130 g
CATV / MATV PASSIVE DEVICES CATV / MATV Surge Protectors (Plastic Pedestal for ART-*)
ART-MP
Model Number System : ART-UV-3A
Protector = A: Arrester Start frequrncy = 1: 10 MHz, 2: 24 MHz 3: 30 MHz, 7: 70 MHz . Pass band = U: UHF, V: VHF . Product series number .
ART-UV-17A-10A
10: 10 dB tap out + high pass filter, 10A: Main output + high pass filter . Protector = A: Arrester Start frequrncy Out/F = 1: 10 MHz, 3: 30 MHz, 7: 70 MHz . Start frequrncy Out = 1: 10 MHz, 3: 30 MHz, 7: 70 MHz . Pass band = U: UHF, V: VHF . Product series number .
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV PASSIVE DEVICES 862 MHz, 2 Outputs Isolated Surge Protector
OUT 10~862MHz IN
OUT/F 70~862MHz HIGH PASS
ART-UV-17A
Features : Low insertion loss for RF signals ADC-3 aluminum alloy die-casting housing with powder coating Special "F" connector for waterproof and good contact Good shielding
Specifications : Description Frequency Range
Specifications In - DATA
10 ~ 862 MHz
In - Out
70 ~ 862 MHz
In - DATA Insertion Loss In - Out Isolation
Out - DATA
10 ~ 862 MHz
4.0 dB typ. 4.6 dB max.
10 ~ 30 MHz
50 dB min.
30 ~ 55 MHz
40 dB min.
70 ~ 862 MHz
4.6 dB typ. 5.2 dB max.
10 ~ 862 MHz
20 dB min.
Return Loss
14 dB min.
High Voltage Protect From input inner conductor to output inner conductor
AC 1KV/ 10mA
From input inner conductor to output outer conductor
during 1 minute
From input outer conductor to output inner conductor From input outer conductor to output outer conductor Connectors
"F" Female
Impedance Waterproof Condition Net Weight
75 2
1.0kg/cm 60seconds 125 g
Specifications are subject to c hange without notice. Special specifications can be s pecified by order.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV PASSIVE DEVICES 770 MHz, 1 Output Isolated Surge Protector Features : Low insertion loss for RF signals ADC-3 aluminum alloy die-casting housing with powder coating Special "F" connector for waterproof and good contact Good shielding
ART-UV-1A (2A, 3A, 7A)
Specifications : Model Number Pass Band
ART-UV-1A
ART-UV-2A
10 ~ 770 (MHz)
Insertion Loss (In - Out)
10 ~ 450
0.5 dB max.
5 ~ 12
450 ~ 770
1.0 dB max.
24 ~ 770
1.0 dB max.
770 ~ 862
1.2 dB max.
Model Number Pass Band
24 ~ 770 (MHz)
ART-UV-3A
ART-UV-7A
30 ~ 770 (MHz)
Insertion Loss (In - Out)
45 dB min.
70 ~ 770 (MHz)
10 ~ 20
45 dB min.
10 ~ 50
45 dB min.
30 ~ 50
1.0 dB max.
70 ~ 90
1.0 dB max.
50 ~ 550
0.5 dB max.
90 ~ 550
0.5 dB max.
550 ~ 770
1.0 dB max.
550 ~ 770
1.0 dB max.
Model Number
ART-UV-1A (2A, 3A, 7A)
Return Loss
14 dB min. 1 KV AC/10 mA during 1 minute
High Voltage Protect
From input inner conductor to output inner/ output conductor From input outer conductor to output inner/ output conductor
Connectors
"F" Female
Impedance
75 1.0 kg/cm 2
Waterproof Condition Dimensions
60 seconds
71 x 63 x 68.5 mm (with connectors)
Weight
114 g
Specifications are subject to c hange without notice. Special specifications can be s pecified by order.
HPF
IN
OUT
IN
ART-UV-1A
OUT
ART-UV-2A (3A, 7A)
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV PASSIVE DEVICES 862 MHz, 2 Outputs + Built-in Diplexer Semi-Isolated Surge Protector
e w N TAP 10dB
OUT 70~862MHz
IN
DATA
5~862MHz
24~55MHz (Revers Band) 70~862MHz (Forward Band)
ARTS-D2455-10
Features : ARTS-D2455-10 features the built-in diplexer to eliminate harmonic distortion for cable modern application; ARTS-D2455-10 with extra high pass filter to eliminate ingress noise. Low insertion loss to RF signals Semi- isolation surge protector for better shielding performance ADC-3 aluminum alloy die-casting housing with powder coating Special "F" connector for waterproof and good contact
Specifications : Description
Freq. Range (MHz) IN - OUT
Insertion Loss IN - DATA
40 dB typ. 30 dB min.
70 ~ 770
2 dB typ. 3.2 dB max.
770 ~ 862
2 dB typ. 3.5 dB max.
5 ~ 12
40 dB typ. 30 dB min. 1.5 dB typ. 2.5 dB max.
70 ~ 862
8.5 dB typ. 10 dB max.
24 ~ 55
14 dB min.
70 ~ 862
10 dB min.
OUT
70 ~ 862
10 dB min.
OUT - DATA
5 ~ 55
30 dB min.
70 ~ 862
18 dB min.
Return Loss
Surge Withstand
5 ~ 55
24 ~ 55
IN, DATA
Isolation
ARTS-D2455-10
IN
Waterproof Condition
1 KV (max.) , 1.2/ 50 us 1.0 kg/cm 2
Impedance
60seconds
75
Connectors
"F" Female
Net Weight
125 g
Specifications are subject to change without notice. Special specifications can br specified by order.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV PASSIVE DEVICES 862 MHz, 2 Outputs Semi-Isolated Surge Protector e w N OUT/F 70-862MHz
IN
OUT 10-862MHz
ARTS-UV-17A
Features : Low insertion loss for RF signals Semi- isolation surge protector for better shielding performance ADC-3 aluminum alloy die-casting housing with powder coating Special "F" connector for waterproof and good contact
Specifications : Description
Freq. Range (MHz) IN - DATA
Insertion Loss IN - OUT
10 ~ 862
ARTS-UV-17A
4.0 dB typ. 4.6 dB max.
10 ~ 30
50 dB min.
30 ~ 55
40 dB min.
70 ~ 862
4.6 dB typ. 5.2 dB max.
Isolation
OUT - DATA
10 ~ 862
20 dB min.
Return Loss
DATA
10 ~ 862
14 dB min.
IN, OUT
70 ~ 862
14 dB min.
Surge Withstand
IN
Waterproof Condition
1 KV (max.) , 1.2/ 50 us 1.0 kg/cm 2
Impedance
60seconds
75
Connectors
"F" Female
Net Weight
120 g
Specifications are subject to change without notice. Special specifications can br specified by order.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV PASSIVE DEVICES 862 MHz, 1 Output Semi-Isolated Surge Protector OUT
IN
e w N
ARTS-UV-1A
OUT
IN
ARTS-UV-1A ( 2A, 7A ) ARTS-UV-2A (7A)
Features : Low insertion loss for RF signals Semi- isolation surge protector for better shielding performance ADC-3 aluminum alloy die-casting housing with powder coating Special "F" connector for waterproof and good contact
Specifications : Description Insertion Loss
Freq. Range (MHz) IN - OUT
Description
ARTS-UV-1A
10 ~ 450
0.5 dB max.
450 ~ 862
1 dB max.
Freq. Range (MHz)
ARTS-UV-2A
5 ~ 12 Insertion Loss
IN - OUT
Description Insertion Loss
24 ~ 770
1.0 dB max.
770 ~ 862
1.2 dB max.
Freq. Range (MHz) IN - OUT
Description IN, OUT
Surge Withstand
IN
ARTS-UV-7A
10 ~ 50
45 dB min.
70 ~ 90
1 dB max.
90 ~ 550
0.5 dB max.
550 ~ 862
1 dB max.
Freq. Range (MHz)
Return Loss
45 dB min.
ARTS-UV-xA
24 ~ 862
Waterproof Condition
14 dB min. 1 KV (max.) , 1.2/ 50 us 2
1.0 kg/cm
Impedance
60seconds
75
Connectors
"F" Female
Net Weight
115 g
Specifications are subject to change without notice. Special specifications can br specified by order. ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan
HEAD-END SYSTEM 750 MHz UHF / VHF Agile Modulator, Rack-Mounted Type
C1000-UVM
Features and Characteristics: Convenient and accurate direct output frequency setting achieved with PLL/digital frequency synthesizer design Low spurious for adjacent channel application (Agile with single-sided band design) Minimum 52 dBmV (112 dB V) RF output level Output level continuously adjustable Volume Control and Visual-Aural carrier level ratio adjustable All controls are front panel accessible. Main AC power loop-through is provided at back panel Built-in 110 ~ 230 V switching power supply for a direct AC powering TV System: PAL-B/G, NTSC
Block Diagram: IF Out 1 AUDIO
2
5
6
7
Channel Filter Out
IF In 8
12
13
14
15
PRE EMP
16
VIDEO
CLAMP
21
22 ATT
9
3
20
4
11
10 PLL
18
17 PLL 19
22
Channel Filter In 22 VHF Out
HEAD-END SYSTEM 750 MHz UHF / VHF Agile Modulator, Rack-Mounted Type Specifications : C1000-UVM
Model Number
PAL B/G
Frequency Range
MHz
Tuning Increment
MHz
NTSC
47 ~ 750 1/10/100
1/10/100
dBmV
+52
Output Level (Adjustable)
dB
0 ~ -18
Output
Aural/Visual Carrier Ratio (Adjustable)
dB
-12 ~ -20
Section
Visual Carrier Frequency Tolerance
KHz
±10
Aural/Visual Carrier Spacing
MHz
Spurious Output (Inband)
dBc
< -52
C/N Ratio In Channel
dB
> 65
Output Level RF
5.5
4.5
75
Output Impedance IF Section
Aural Frequency
MHz
33.4
41.25
Visual Frequency
MHz
38.9
45.75
Composite IF Loop Output
Aural Carrier Level
dBmV
+20
Visual Carrier Level
dBmV
+35 75
Output/Input Impedance Vp-p
Input Level Frequency Response
Video Section
f v - 0.5 MHz to f v + 4.75 MHz
dB
f v - 0.5 MHz to f v + 4.2 MHz
dB
0.6 ~ 1.5
-
±1.0
±1.0
P-P Video to RMS Hum Ratio
dB
48
Video S/N Ratio, Weighted
dB
58
Differential Gain
%
<4
deg
<4
C/L Delay Inequality
ns
< 20
Over Modulation Indicator
%
87.5 ± 2.5
Differential Phase
75
Input Impedance
Audio Section
Input Level for 50KHz deviation, source impedance 600
dBm
-8 ~ 10
-
Input Level for 25KHz deviation, source impedance 600
dBm
-
-8 ~ 10
Frequency Response
50 Hz to 15 KHz
dB
±3.0
400 Hz to 10 KHz
dB
±1.0
Pre-Emphasis-Mono
us
Audio S/N
dB
60
Total Harmonic Distortion
%
<1
Over Modulation Indicator
KHz
75
50 ± 2
25 ± 2
10K, unbalanced
Input Impedance Voltage
Vac
110 ~ 230
Frequency
Hz
60 / 50
mA
250
Temperature Range
°C
0 to +50
Power Consumption
W
12
Dimension
mm
483 x 44 x 285
Net Weight
Kg
3.3
Power Requirements General
50
Fuse
Specifications are subject to change without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
HEAD-END SYSTEM 862 MHz UHF / VHF Agile Modulator, Rack-Mounted Type
C1000-UVM
Features and Characteristics: Convenient and accurate direct output frequency setting achieved with PLL/digital frequency synthesizer design Low spurious for adjacent channel application (Agile with single-sided band design) Minimum 52 dBmV (112 dBuV) RF output level Output level continuously adjustable Volume Control and Visual-Aural carrier level ratio adjustable All controls are front panel accessible. Main AC power loop-through is provided at back panel Built-in 110 ~ 230 V switching power supply for a direct AC powering TV System: PAL-B/G, NTSC
Block Diagram: IF Out 1 AUDIO
2
5
6
7
Channel Filter Out
IF In 8
12
13
14
15
PRE EMP
16
VIDEO
CLAMP
21
22 ATT
9
3
20
4
11
10 PLL
18
17 PLL 19
22
Channel Filter In 22 VHF Out
HEAD-END SYSTEM 862 MHz UHF / VHF Agile Modulator, Rack-Mounted Type Specifications : C1000-UVM
Model Number
PAL B/G
Frequency Range
MHz
Tuning Increment
MHz
NTSC
47 ~ 862 1/10/100
1/10/100
dBmV
+52
Output Level (Adjustable)
dB
0 ~ -18
Output
Aural/Visual Carrier Ratio (Adjustable)
dB
-12 ~ -20
Section
Visual Carrier Frequency Tolerance
KHz
±10
Aural/Visual Carrier Spacing
MHz
Spurious Output (Inband)
dBc
< -52
C/N Ratio In Channel
dB
> 65
Output Level RF
5.5
4.5
75
Output Impedance IF Section
Aural Frequency
MHz
33.4
41.25
Visual Frequency
MHz
38.9
45.75
Composite IF Loop Output
Aural Carrier Level
dBmV
+20
Visual Carrier Level
dBmV
+35 75
Output/Input Impedance Vp-p
Input Level Frequency Response
Video Section
f v - 0.5 MHz to f v + 4.75 MHz
dB
f v - 0.5 MHz to f v + 4.2 MHz
dB
0.6 ~ 1.5
-
±1.0
±1.0
P-P Video to RMS Hum Ratio
dB
48
Video S/N Ratio, Weighted
dB
58
Differential Gain
%
<4
deg
<4
C/L Delay Inequality
ns
< 20
Over Modulation Indicator
%
87.5 ± 2.5
Differential Phase
75
Input Impedance
Audio Section
Input Level for 50KHz deviation, source impedance 600
dBm
-8 ~ 10
-
Input Level for 25KHz deviation, source impedance 600
dBm
-
-8 ~ 10
Frequency Response
50 Hz to 15 KHz
dB
±3.0
400 Hz to 10 KHz
dB
±1.0
Pre-Emphasis-Mono
us
Audio S/N
dB
60
Total Harmonic Distortion
%
<1
Over Modulation Indicator
KHz
75
50 ± 2
25 ± 2
10K, unbalanced
Input Impedance Voltage
Vac
110 ~ 230
Frequency
Hz
60 / 50
mA
250
Temperature Range
°C
0 to +50
Power Consumption
W
12
Dimension
mm
483 x 44 x 285
Net Weight
Kg
3.3
Power Requirements General
50
Fuse
Specifications are subject to change without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
SATELLITE TVRO DEVICES Accessories for Outlet Socket
COVER-300
COVER-300A
FRAME-300
FRAME-300A
DCB-01
COVER-400A
CVP-273
TR-1
Features : COVER-300: Wall outlet cover with round edges COVER-300A: Wall outlet cover with square shape COVER-400A: Cover for 4-output outlet FRAME-300: Wall outlet frame with round edges FRAME-300A: Wall outlet frame with square shape DCB-01 : DC Block/RF Pass CVP-273 : 75 terminator for "F" female ports TR-1 is a 75 terminator for all types TV wall outlets except MX-600A series wall outlet socket, because it is not a DC block terminator Redundant port should be properly terminated to maintain the best performance of the entire distribution network
Specifications : Description Dimensions Packing Accessories
COVER-300
COVER-300A/400A
FRAME-300
FRAME-300A
76 x 76 x 9 (mm)
80 x 80 x 8 (mm)
76 x 76 x 32 (mm)
80 x 80 x 32 (mm)
1000 pcs per Carton
200 pcs per carton
2 pairs of screws included per set
4 pairs of screws included per set
Material, Color Description Connectors Standard Packing DC blocking
ABS plastic; white, Off white DCB-01
CVP-273
TR-1
"F" Female / Male
"F" Male
N/A
100 pcs per P.E. bag
100 pcs per P.E. bag
500 pcs per P.E. bag
YES
Impedance
NO 75
Specifications are subject to c hange without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV PASSIVE DEVICES Covers for Outlet Socket
COVER-200
COVER-301B
COVER-200A
COVER-401A
Specifications : Description
COVER-200
COVER-200A/401A
COVER-301B
Dimensions
76 x 76 x 9 (mm)
80 x 80 x 8 (mm)
84 x 84 x 8 (mm)
TV, Radio
TV, Radio / TV, Radio, Data1, Data2
TV, Radio, Data
Ports Color
white, off white
Material
ABS plastic
Packing
1000 pcs per Carton
Weight
7.7 Kg per Carton ( packing and screws included )
Accessories
2 pairs of screws included per set
Specifications Specifications are subject to c hange without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan ZINWELL Corporation
CATV / MATV INDOOR AMPLIFIER
1000 MHz Mini Drop Amplifier
DA-110 series
Features : Mini size Up to 1000 MHz Bi-directional Superior flatness Remote or local power supply supply available Power indication Surge protection Suitable for multimedia CATV CATV and Cable Modem application
Application Diagram :
(Option)
Local Power Supply
Remote Power Supply
CATV / MATV INDOOR AMPLIFIER
1000 MHz Mini Drop Amplifier Specifications : Description Gain
DA-110-xx
5 ~ Fr
-1.5 dB min.
Fd ~ 1000
11.5 1 dB
Return Loss Noise Figure
16 dB min. Fr ~ 750
5.5 dB typ.
750 ~ 1000
6.5 dB typ.
Output level
77 chs 75 dBuV
Composite Second Order (CSO)
-55 dBc
Composite Triple Beat (CTB)
-60 dBc
Supply Voltage
12 ~ 16 VDC , Local Powering or Remote Powering
Current Dissipation
70 mA typ.
Surge Protection
1kV, ring wave , high impedance
Impedance
Connector
"F" Female
Net Weight
85 g
Standard Accessory
Power adaptor 12 ~ 16 VDC, 200 mA an and Co Coaxial Cable
Optional Accessory
Power Inserter (HDA-PI)
75 £
Specifications Specifications are subject to c hange without notice. DA-110-F54R42
Fr= 42 MHz, Fd= 54 MHz
DA-110-F70R55
Fr= 55 MHz, Fd= 70 MHz
DA-110-F84R65
Fr= 65 MHz, Fd= 84 MHz
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan ZINWELL Corporation
CATV OUTDOOR AMPLIFIER
Plug-in Module Series, Diplexer and High Pass Filters Modules
DPX-** Diplexers
Specifications : Model Number
DPX-30/47
DPX-40/51
DPX-42/54
Freq. Range 5 ~ 30
Insertion
Freq.
47 ~ 400
40
51 ~ 350
40
54 ~ 350
Loss
High
5 ~ 30
40
5 ~ 40
40
(dB)
Freq.
47 ~ 860
0.8
51 ~ 860
5 ~ 450
40
450 ~ 860
25
(dB)
DPX-65/84
5 ~ 860 MHz
Low
Isolation (MHz)
DPX-55/70
0.75
5 ~ 40
0.75
5 ~ 42
0.75
5 ~ 55
1
5 ~ 65
1
40
70 ~ 300
40
84 ~ 350
40
5 ~ 42
40
5 ~ 55
40
5 ~ 65
40
0.8
54 ~ 860
0.8
70 ~ 860
1
84 ~ 860
1
5 ~ 450
40
5 ~ 450
40
5 ~ 450
40
5 ~ 450
40
450 ~ 860
25
450 ~ 860
25
450 ~ 860
25
450 ~ 860
25
5~7
30
5~7
30
5~7
30
5~7
30
5~7
30
Return
Input
7 ~ 30
25
7 ~ 40
20
7 ~ 42
20
7 ~ 55
18
7 ~ 65
18
Loss
(MHz)
47 ~ 400
20
51 ~ 350
20
54 ~ 350
20
70 ~ 300
18
84 ~ 350
18
400 ~ 860
18
350 ~ 860
17
350 ~ 860
17
300 ~ 860
17
350 ~ 860
16
Low
5~7
30
5~7
30
5~7
30
5~7
30
5~7
30
(MHz)
7 ~ 30
25
7 ~ 40
20
7 ~ 42
20
7 ~ 55
18
7 ~ 65
18
High
47 ~ 400
20
51 ~ 350
20
54 ~ 350
20
70 ~ 300
18
84 ~ 350
18
(MHz)
400 ~ 860
18
350 ~ 860
17
350 ~ 860
17
300 ~ 860
17
350 ~ 860
16
(dB)
Impedance Dimensions Weight
75 50.2(L) x 15.2(W) x 34(H) m m 10 g
Specification are subject to change without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV PASSIVE DEVICES Indoor VHF/ UHF Diplexer
LPF VHF OUT (5~250MHz) INPUT
HPF UHF OUT (470~900MHz)
DUV-250
Features : Used for 5 ~ 250 MHz/ 470 ~ 900 MHz separation or combination RFI shielding and zinc alloy die-casting case with nickel plated 350 mA bi-directional power passing for IN-UHF
Specifications: Description
Freq. Range (MHz)
DUV - 250
5 ~ 250
1 dB max.
470 ~ 900
20 dB min.
40 ~ 250
20 dB min.
470 ~ 900
1 dB max.
40 ~ 250
20 dB min.
470 ~ 900
20 dB min.
5 ~ 250
10 dB min.
470 ~ 900
10 dB min.
VHF OUT
5 ~ 250
10 dB min.
UHF OUT
470 ~ 900
10 dB min.
IN - VHF Insertion Loss IN - UHF Isolation
VHF - UHF
IN
Return Loss
Power Pass
IN
UHF
350 mA
Connectors
"F" Female
Impedance
75
Dimensions (with connectors)
56 x 50 x 22 mm
Weight
61 g
Specifications are subject to c hange without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV OUTDOOR AMPLIFIER Plug-in Module Series, Jumper and Attenuators Modules
FA-0
FA-** Attenuators
Jumper
Specifications : Description
5 ~ 1000
Frequency Range (MHz)
Return Loss (dB)
5 ~ 750 MHz
28 typ. 24 min.
750 ~ 1000 MHz
24 typ. 20 min. 75
Impedance 5 ~ 750 MHz
Flatness (dB)
750 ~ 1000 MHz
Dimensions
±
0.3
±
0.4
39.2(L) x 19.2(W) x 34(H) mm
Weight
6g
Through Value Freq. Range
FA-0
FA-1
FA-2
FA-3
FA-4
FA-5
FA-6
FA-7
FA-8
FA-9
FA-10
5 ~ 550
0.10
1
2
3
4
5
6
7
8
9
10
550 ~ 750
0.10
1.1
2.1
3.1
4.1
5.1
6.1
7.1
8.1
9.1
10.1
750 ~ 1000
0.15
1.2
2.2
3.2
4.2
5.2
6.2
7.2
8.2
9.2
10.2
FA-12
FA-13
FA-14
FA-15
FA-16
FA-17
FA-18
FA-19
FA-20
11
12
13
14
15
16
17
18
19
20
550 ~ 750
11.1
12.1
13.1
14.1
15.1
16.1
17.1
18.1
19.1
20.1
750 ~ 1000
11.2
12.2
13.2
14.2
15.2
16.2
17.2
18.2
19.2
20.2
Freq. Range FA-11 5 ~ 550
Specifications are subject to change without no tice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Single Output
FMT-5510F
Features : Wide operating voltage range 30 ~ 90 V AC Modular design making maintenance easy and function flexible Optional reverse amplifier and transmitter module providing capability of advanced two-way data, video, and telephony services Uses hybrid module for power doubling amplification Forward single output with an optional tap output Mounting scheme: strand or pedestal installation All RF / AC ports are equipped with arresters for protection Automatic level control (ALC) with high/ low switch for easy setup
Descriptions : The FMT-5510 is the best solution for delivering video, data and telephony service over the HFC network. The optical node is offered with a variety of plug-in pads, equalizers, directional couplers and automatic level control in order to customize the unit to your coaxial link and frequency plan. The optical input level indicators are displayed with red and green LEDs, for monitoring the lower, normal and higher input level according to -7 dBm ~ +3 dBm. The optical input test point can read the optical input level accurately by measuring the DC level directly. The modular design of the optical reverse transmitter makes field installation easy. Any existing Zinwell's MT-35 series can be upgraded to trunk line optical node function by replacing the original one with the top cover of FMT-55 series.
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Single Output Block Diagram :
Specifications : RF Amplifier Model Number
FMT-5510F-28PD
Frequency Range
MHz
862
Frequency Response
dB
0.75
Mini Full Gain
dB
28
Operation
Not include ALC
dB
26
Gain
Include ALC
dB
26
Gain Control
Adjustable
dB
0 ~ 18
(Plug-in)
Fixed
dB
0 ... 9 (in 1 dB step)
Slope Control
Adjustable
dB
None
(Plug-in)
Fixed
dB
0, 3, 6, 8, 9
AGC (Thermal compensation)
dB
2 (built-in)
ALC (Auto level control)
dB
4 (optional)
NTSC
77 chs. +
Ref. Output Level*
312 MHz digital dBuV
97 / 104 / 98 (55 / 550 / 862 MHz)
Composite Second Order (CSO)
dB
-63
Composite Triple Beat (CTB)
dB
-63
Cross Modulation (XMOD)
dB
-62
Noise Figure
dB
8
Return Loss
dB
16 typ. 12 min.
Current Consumption
mA
1200 including RA: 80 / ALC: 60
Specifications are subject to change without not ice.
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Single Output Receiver Module Output Frequency Range
MHz
47 ~ 862
Input Optical Wavelength
nm
1250 ~ 1600
Input Power Range
mW
0.2 ~ 2 (-7 dBm ~ 3 dBm)
Absolute Max. Input Power
mW
5 (7 dBm)
Frequency Response
dB
0.5
Optical Input Return Loss
dB
40
Output Return
47 ~ 550 MHz
dB
16
Loss
550 ~ 862 MHz
dB
14
RF Output Level*
-3 dBm Optical Input
dBmV
19 0.8 (79 dBuV)
0 dBm Optical Input
dBmV
25 0.8 (85 dBuV)
Input Connector
FC / APC
Input Optical Type
Cladding 125 um, cor 9 um
9 / 125 Single mode
Green On
Normal (0.2 mW ~ 2 mW)
Red On
Over (> 2 mW)
Green & Red Off
Below (< 0.2 mW)
LED Indicator
Input Optical Test Point
V
0.5 mW (-3 dBm) = 0.5 V , 1.0 mW (0 dBm) = 1.0 V
(1 volt / 1 mW)
2.0 mW (+3 dBm) = 2.0 V,
Current Consumption
DC
250 mA max. @ 24 V DC
* Assumes 3.8% modulati on index per channel, 1310(min.)
Transmitter Module (Optional) Frequency Range
MHz
5 ~ 100
Current Consumption
mA
50
Output Power
mW
0.5 (-3 dBm)
Optical Fiber
core 9 um,
9 / 125 single mode
cladding 125 um Wavelength Power Consumption RF input to Transmitter
nm
1310
W
0.5 @ 24 V DC, 20 mA
dBuV
90 dBuV *
Output Connector
FC/ APC C/N (dB)
2 ch., 3 ch.
4 ch.
5 ch.
Optical Link Loss
(@ RF input level=
(@ RF input level=
(@ RF input level=
(dB)
96 dBuV )
92 dBuV )
90 dBuV )
0
58
56
54
3
55
53
51
6
52
50
48
9
49
47
45
12
46
44
42
* Channel loading is 5 CW carriers at T7 through T11 with the reference RF input level.
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Single Output General Specifications : I/O Test Ports
dB
-20 1 , to input & output level
Switching Power Supply Output Rating
A
1.5 @ 24 V DC
Surge Protection
V
7,000, 1.2 x 50 s
Power Consumption &
W
31 @ 35 ~ 90 V DC; 30 ~ 90 V AC
Requirement
47 ~ 63 Hz square or sinusoidal wave
Operationg Temperature
C
-40 ~ +60
Operating Humidity
%
5 ~ 95
mm
320(L) x 255(W) x 140(H)
Dimensions (with connectors)
5/8" - 24 NEF Female
Thread Ports for In/Out Conn.
Impedance
75
Net Weight
Kg
Specifications are subject to change without not ice.
Model Number System : FMT-5510 F - 28 PD PD -- Power doubling Forward gain -- 28dB Frequency range F -- 862 Mhz One outputBone tap out Optical transmitter & receiver node
OER - 55 20 F F -- 862 MHz 20 -- 2.0 mW FMT-55 series use OER -- Optical-to-electrical receiver
ORT - 55 05 FP FP -- FP type transmitter 05 -- 0.5 mW FMT-55 series use ORT -- Optical reverse transmitter
5.5
CATV OUTDOOR AMPLIFIER Modules & Plug-in Position of FMT-5510F
862 MHz FS-86/6
Module
Type
Module Code
Module Description
Remark
Input EQ.
Fixed value
FA-0
0 ~ 1000 MHz, 0 dB Jumper
Standard
Attenuator
Fixed value
FA-0, 1, 2 ~ 10
Fixed value pad
Adjustable
MA-18
0 ~ 18 dB adj. attenuator
Fixed value
FA-0
0 ~ 1000 MHz, 0dB Jumper
FS-86/3, 6, 8, 9, 11,
860 MHz fixed value input EQ.
Output EQ.
12, 14, 16, 17, 19 ALC
ALC-04
4 dB Automatic Level Control
TOE-4/4
862 MHz 4 dB splitter
Output
TOE-6/2
862 MHz 6 dB tap off
Passive
TOE-10/1
862 MHz 10 dB tap off
TOE-15/1
862 MHz 15 dB tap off
DPX-30/47
5 ~ 30 MHz & 47 ~ 862 MHz Split
DPX-40/51
5 ~ 40 MHz & 51 ~ 862 MHz Split
DPX-42/54
5 ~ 42 MHz & 54 ~ 862 MHz Split
DPX-55/70
5 ~ 55 MHz & 70 ~ 862 MHz Split
DPX-65/84
5 ~ 65 MHz & 84 ~ 862 MHz Split
RB-J0
0 ~ 1000 MHz, 0 dB Jumper
RA-18E-30 (30A)
5 ~ 30 MHz 18 dB Gain
RA-18E-40 (A)
5 ~ 40 MHz 18 dB Gain
RA-18E-42A
5 ~ 42 MHz 18 dB Gain
RA-18E-55 (55A)
5 ~ 55 MHz 18 dB Gain
RA-18E-65 (65A)
5 ~ 65 MHz 18 dB Gain
Diplexer
Reverse
* Standard: module will be included with shipment Please see the detailed specifications of plug-in modules from Zinwell's catalog.
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Single Output Assembly Diagram :
Optional plug-in type reverse transmitter ORT-5505FP
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Balanced Dual Output
FMT-5520 F
Features : Wide operating voltage range 30 ~ 90 V AC Optical level indicators available Modular design making maintenance easy and function flexible Optional reverse amplifier and transmitter module providing capability of advanced two-way data, video, and telephony services Uses hybrid module for power doubling amplification Forward balance dual output Mounting scheme: strand or pedestal installation All RF / AC ports are equipped with arresters for protection Automatic level control (ALC) with a high/ low switch for easy setup
Descriptions : The FMT-5520 is the best solution for delivering video, data and telephony service over the HFC network. The optical node is offered with a variety of plug-in pads, equalizers, directional couplers and automatic level control in order to customize the unit to your coaxial link and frequency plan. The optical input level indicators are displayed with red and green LEDs, for monitoring the lower, normal and higher input level according to -7 dBm ~ +3 dBm. The optical input test point can read the optical input level accurately by measuring the DC level directly. The modular design of the optical reverse transmitter makes field installation easy. Any existing Zinwell's MT-35 series can be upgraded to trunk line optical node function by replacing the original one with the top cover of FMT-55 series.
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Balanced Dual Output Block Diagram :
Specifications : RF Amplifier Model Number
FMT-5520F-28PD
Frequency Range
MHz
862
Frequency Response
dB
0.75
Mini Full Gain
dB
28
Operation
Not include ALC
dB
26
Gain
Include ALC
dB
26
Gain Control
Adjustable
dB
0 ~ 18
(Plug-in)
Fixed
dB
0 ... 9 (in 1 dB step)
Slope Control
Adjustable
dB
None
(Plug-in)
Fixed
dB
0, 3, 6, 8, 9
AGC (Thermal compensation)
dB
2 (built-in)
ALC (Auto level control)
dB
4 (optional)
NTSC
129 chs.
dBuV
97 / 106
Ref. Output Level*
(55 / 862 MHz) Composite Second Order (CSO)
dB
-59
Composite Triple Beat (CTB)
dB
-52
Cross Modulation (XMOD)
dB
-60
Noise Figure
dB
8
Return Loss
dB
16 typ. 12 min.
Current Consumption
mA
1200 including RA: 80 / ALC: 60
Specifications are subject to change without not ice.
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Balanced Dual Output Receiver Module Output Frequency Range
MHz
47 ~ 862
Input Optical Wavelength
nm
1250 ~ 1600
Input Power Range
mW
0.2 ~ 2 (-7 dBm ~ 3 dBm)
Absolute Max. Input Power
mW
5 (7 dBm)
Frequency Response
dB
0.5
Optical Input Return Loss
dB
40
Output Return
47 ~ 550 MHz
dB
16
Loss
550 ~ 862 MHz
dB
14
RF Output Level*
-3 dBm Optical Input
dBmV
19 0.8 (79 dB V)
0 dBm Optical Input
dBmV
25 0.8 (85 dB V)
Input Connector Input Optical Type
FC / APC Cladding 125 m, cor 9 m
9 / 125 Single mode
Green On
Normal (0.2 mW ~ 2 mW)
Red On
Over (> 2 mW)
Green & Red Off
Below (< 0.2 mW)
LED Indicator
Input Optical Test Point
V
0.5 mW (-3 dBm) = 0.5 V , 1.0 mW (0 dBm) = 1.0 V
(1 volt / 1 mW)
2.0 mW (+3 dBm) = 2.0 V…
Current Consumption
DC
250 mA max. @ 24 V DC
* Assumes 3.8% modulati on index per channel, 1310(min.)
Transmitter Module (Optional) Frequency Range
MHz
5 ~ 100
Current Consumption
mA
50
Output Power
mW
0.5 (-3 dBm)
Optical Fiber
core 9 m,
9 / 125 single mode
cladding 125 m Wavelength Power Consumption RF input to Transmitter
nm
1310
W
0.5 @ 24 V DC, 20 mA
dBV
90 dBV *
Output Connector
FC/ APC C/N (dB)
2 ch., 3 ch.
4 ch.
5 ch.
Optical Link Loss
(@ RF input level=
(@ RF input level=
(@ RF input level=
(dB)
96 dBV )
92 dBV )
90 dBV )
0
58
56
54
3
55
53
51
6
52
50
48
9
49
47
45
12
46
44
42
* Channel loading is 5 CW carriers at T7 through T11 with the reference RF input level.
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Balanced Dual Output General Specifications : I/O Test Ports
dB
-20 1 , to input & output level
Switching Power Supply Output Rating
A
1.5 @ 24 V DC
Surge Protection
V
7,000, 1.2 x 50 s
Power Consumption &
W
42 @ 35 ~ 90 V DC; 30 ~ 90 V AC
Requirement
47 ~ 63 Hz square or sinusoidal wave
Operationg Temperature
C
-40 ~ +60
Operating Humidity
%
5 ~ 95
mm
320(L) x 255(W) x 140(H)
Dimensions (with connectors)
5/8" - 24 NEF Female
Thread Ports for In/Out Conn.
Impedance
75
Net Weight
Kg
Specifications are subject to change without not ice.
Model Number System : FMT-5520F-28PD PD: Power doubling Forward gain -- 28dB Frequency range F -- 862 MHz Balanced dual output, no tap out Optical transmitter & receiver node
OER - 55 20 F F -- 862 MHz 20 -- 2.0 mW FMT-55 series use OER -- Optical-to-electrical receiver
ORT - 55 05 FP FP -- FP type transmitter 05 -- 0.5 mW FMT-55 series use ORT -- Optical reverse transmitter
Note : For assembly diagram, please refer to FMT-5510F.
5.5
CATV OUTDOOR AMPLIFIER Modules & Plug-in Position of FMT-5520F
862 MHz FS-86/6
Module
Type
Module Code
Module Description
Remark
Input EQ.
Fixed value
FA-0
0 ~ 1000 MHz, 0 dB Jumper
Standard
Attenuator
Fixed value
FA-0, 1, 2 ~ 10
Fixed value pad
Adjustable
MA-18
0 ~ 18 dB adj. attenuator
Fixed value
FA-0
0 ~ 1000 MHz, 0dB Jumper
FS-86/3, 6, 8, 9, 11,
860 MHz fixed value input EQ.
Output EQ.
12, 14, 16, 17, 19 ALC
Diplexer
Reverse
ALC-04
4 dB Automatic Level Control
DPX-30/47
5 ~ 30 MHz & 47 ~ 862 MHz Split
DPX-40/51
5 ~ 40 MHz & 51 ~ 862 MHz Split
DPX-42/54
5 ~ 42 MHz & 54 ~ 862 MHz Split
DPX-55/70
5 ~ 55 MHz & 70 ~ 862 MHz Split
DPX-65/84
5 ~ 65 MHz & 84 ~ 862 MHz Split
RB-J0
0 ~ 1000 MHz, 0 dB Jumper
RA-18E-30 (30A)
5 ~ 30 MHz 18 dB Gain
RA-18E-40 (A)
5 ~ 40 MHz 18 dB Gain
RA-18E-42A
5 ~ 42 MHz 18 dB Gain
RA-18E-55 (55A)
5 ~ 55 MHz 18 dB Gain
RA-18E-65 (65A)
5 ~ 65 MHz 18 dB Gain
* Standard: module will be included with shipment Please see the detailed specifications of plug-in modules from Zinwell's catalog.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Unbalanced Dual Output
FMT-5530F
Features : Wide operating voltage range 30 ~ 90 V AC Optical level indicators available Modular design making maintenance easy and function flexible Optional reverse amplifier and transmitter module providing capability of advanced two-way data, video, and telephony services Uses hybrid module for power doubling amplification Forward unbalanced dual output Mounting scheme: strand or pedestal installation All RF / AC ports are equipped with arresters for protection Automatic level control (ALC) with a high/ low switch for easy setup
Descriptions : The FMT-5530 is the best solution for delivering video, data and telephony services over the HFC network. The optical node is offered with a variety of plug-in pads, equalizers, directional couplers and automatic level control in order to customize the unit to your coaxial link and frequency plan. The optical input level indicators are displayed with red and green LEDs, for monitoring the lower, normal and higher input level according to -7 dBm ~ +3 dBm. The optical input test point can read the optical input level accurately by measuring the DC level directly. The modular design of the optical reverse transmitter makes field installation easy. Any existing Zinwell's MT-35 series can be upgraded to trunk line optical node function by replacing the original one with the top cover of FMT-55 series.
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Unbalanced Dual Output Block Diagram :
Specifications : Forward Path Model Number
FMT-5530F-2636PD MAIN
AUX
AMP. Type
Power Doubling
Frequency Range
MHz
862
Frequency Response
dB
0.75
Mini Full Gain
dB
26
36
Operation Gain
Not include
dB
24
34
(ALC)
Include
dB
24
34
Gain Control
Adjustable
dB
0 ~ 18
(Plug-in Module)
Fixed
dB
0 ... 20 (in 1 dB step)
Slope Control
Adjustable
dB
None
(Plug-in Module)
Fixed
dB
0, 3, 6, 8, 9
AGC (Thermal Compensation)
dB
2 (Built -in)
ALC (Auto Level Control)
dB
4
Operating Tilt
dB
9
Output Level
NTSC
77 chs. +
77 chs. +
(Reference)
chs.
312 MHz digital
312 MHz digital
dBuV
90 / 94 / 87
97 / 104 / 98
(MHz)
(55 / 550 / 862)
(55 / 550 / 862)
Composite Second Order (CSO)
dB
-68
-61
Composite Triple Beat (CTB)
dB
-67
-60
Cross Modulation (XMOD)
dB
-65
-62
Noise Figure
dB
8
9
Return Loss
dB
16 typ. 12 min.
Current Consumption
mA
1200 including RA: 80 / ALC: 60
Specifications are subject to change without not ice.
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Unbalanced Dual Output Receiver Module Output Frequency Range
MHz
47 ~ 862
Input Optical Wavelength
nm
1250 ~ 1600
Input Power Range
mW
0.2 ~ 2 (-7 dBm ~ 3 dBm)
Absolute Max. Input Power
mW
5 (7 dBm)
Frequency Response
dB
0.5
Optical Input Return Loss
dB
40
Output Return
47 ~ 550 MHz
dB
16
Loss
550 ~ 862 MHz
dB
14
RF Output Level*
-3 dBm Optical Input
dBmV
19 0.8 (79 dB V)
0 dBm Optical Input
dBmV
25 0.8 (85 dB V)
Input Connector Input Optical Type
FC / APC Cladding 125 m, cor 9 m
9 / 125 Single mode
Green On
Normal (0.2 mW ~ 2 mW)
Red On
Over (> 2 mW)
Green & Red Off
Below (< 0.2 mW)
LED Indicator
Input Optical Test Point
V
0.5 mW (-3 dBm) = 0.5 V , 1.0 mW (0 dBm) = 1.0 V
(1 volt / 1 mW)
2.0 mW (+3 dBm) = 2.0 V…
Current Consumption
DC
250 mA max. @ 24 V DC
* Assumes 3.8% modulati on index per channel, 1310(min.)
Transmitter Module (Optional) Frequency Range
MHz
5 ~ 100
Current Consumption
mA
50
Output Power
mW
0.5 (-3 dBm)
Optical Fiber
core 9 m,
9 / 125 single mode
cladding 125 m Wavelength Power Consumption RF input to Transmitter
nm
1310
W
0.5 @ 24 V DC, 20 mA
dBV
90 dBV *
Output Connector
FC/ APC C/N (dB)
2 ch., 3 ch.
4 ch.
5 ch.
Optical Link Loss
(@ RF input level=
(@ RF input level=
(@ RF input level=
(dB)
96 dBV )
92 dBV )
90 dBV )
0
58
56
54
3
55
53
51
6
52
50
48
9
49
47
45
12
46
44
42
* Channel loading is 5 CW carriers at T7 through T11 with the reference RF input level.
CATV OUTDOOR AMPLIFIER Trunk Line Optical Node with Forward Unbalanced Dual Output General Specifications : I/O Test Ports
dB
-20 1 , to input & output level
Switching Power Supply Output Rating
A
1.5 @ 24 V DC
Surge Protection
V
7,000, 1.2 x 50 s
Power Consumption &
W
42 @ 35 ~ 90 V DC; 30 ~ 90 V AC
Requirement
47 ~ 63 Hz square or sinusoidal wave
Operationg Temperature
C
-40 ~ +60
Operating Humidity
%
5 ~ 95
mm
320(L) x 255(W) x 140(H)
Dimensions (with connectors)
5/8" - 24 NEF Female
Thread Ports for In/Out Conn.
Impedance
75
Net Weight
Kg
Specifications are subject to change without not ice.
Model Number System : FMT-5530F-2636PD PD: Power doubling AUX out gain: 36 -- 36 dB gain Line out gain: 26 -- 26 dB gain Frequency range F -- 862 MHz Unbalanced dual output, no tap out Optical transmitter & receiver node
OER - 55 20 F F -- 862 MHz 20 -- 2.0 mW FMT-55 series use OER -- Optical-to-electrical receiver
ORT - 55 05 FP FP -- FP type transmitter 05 -- 0.5 mW FMT-55 series use ORT -- Optical reverse transmitter
Note : For assembly diagram, please refer to FMT-5510F.
5.5
CATV OUTDOOR AMPLIFIER Modules & Plug-in Position of FMT-5530F
862 MHz FS-86/6
Module
Type
Module Code
Module Description
Remark
Input EQ.
Fixed value
FA-0
0 ~ 1000 MHz, 0 dB Jumper
Standard
Attenuator
Fixed value
FA-0, 1, 2 ~ 10
Fixed value pad
Adjustable
MA-18
0 ~ 18 dB adj. attenuator
Fixed value
FA-0
0 ~ 1000 MHz, 0dB Jumper
FS-86/3, 6, 8, 9, 11,
860 MHz fixed value input EQ.
Output EQ.
12, 14, 16, 17, 19 ALC
Diplexer
Reverse
ALC-04
4 dB Automatic Level Control
DPX-30/47
5 ~ 30 MHz & 47 ~ 862 MHz Split
DPX-40/51
5 ~ 40 MHz & 51 ~ 862 MHz Split
DPX-42/54
5 ~ 42 MHz & 54 ~ 862 MHz Split
DPX-55/70
5 ~ 55 MHz & 70 ~ 862 MHz Split
DPX-65/84
5 ~ 65 MHz & 84 ~ 862 MHz Split
RB-J0
0 ~ 1000 MHz, 0 dB Jumper
RA-18E-30 (30A)
5 ~ 30 MHz 18 dB Gain
RA-18E-40 (A)
5 ~ 40 MHz 18 dB Gain
RA-18E-42A
5 ~ 42 MHz 18 dB Gain
RA-18E-55 (55A)
5 ~ 55 MHz 18 dB Gain
RA-18E-65 (65A)
5 ~ 65 MHz 18 dB Gain
* Standard: module will be included with shipment Please see the detailed specifications of plug-in modules from Zinwell's catalog.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV PASSIVE DEVICES Frame for Outlet Socket
FRAME-300A
FRAME-300
FRAME-300B
Specifications : Description
FRAME-300
FRAME-300A
Color
FRAME-300B
white, off white
Material
ABS plastic
Dimensions
76 x 76 x 32 (mm)
80 x 80 x 32 (mm)
84 x 84 x 30 (mm)
Packing
200 pcs per carton
Weight
7.7 Kg per Carton ( packing and screws included )
Accessories
4 pairs of screws included per set
Specifications are subject to c hange without notice.
Accessories for Outlet Socket Features :
DCB-01
CVP-273
DCB-01 : DC Block/RF Pass CVP-273 : 75 terminator for "F" female ports TR-1 is a 75 terminator designed to match the metal clip port of all wall outlet socket TR-1 cannot be used with the model MX-600A-( ) series, because this is not a DC/AC block terminator
TR-1
Specifications : Description
DCB-01
CVP-273
TR-1
"F" Female / Male
"F" Male
N/A
100 pcs per P.E. bag
100 pcs per P.E. bag
500 pcs per P.E. bag
Connectors Standard Packing DC blocking Impedance
YES
NO 75
Specifications are subject to change without not ice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV OUTDOOR AMPLIFIER Plug-in Module Series, Fixed Equalizer Modules
FS-55/** (550 MHz EQ) FS-75/** (750 MHz EQ) FS-86/** (860 MHz EQ)
Specifications : Model Number
FS-55/**
FS-75/**
FS-86/**
47 ~ 550 MHz
47 ~ 750 MHz
47 ~ 860 MHz
Frequency Range
22 typ. 18 min.
Return Loss (dB)
0.4 typ. 1.0 max.
Insertion Loss (dB)
75
Impedance Dimensions
39.2(L) x 19.2(W) x 34(H ) mm 6g
Weight Freq. Range
FS-55/1
FS-55/2
FS-55/3
FS-55/4
FS-55/5
FS-55/6
FS-55/7
FS-55/8
FS-55/9
FS-55/10
54 ~ 550
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
47 ~ 550
1.1
2.1
3.1
4.2
5.3
6.3
7.3
8.3
9.3
10.4
Freq. Range
FS-55/11 FS-55/12 FS-55/13 FS-55/14 FS-55/15 FS-55/16 FS-55/17 FS-55/18 FS-55/19 FS-55/20
54 ~ 550
11.0
12.0
13.0
14.0
15.0
16.0
17.0
18.0
19.0
20.0
47 ~ 550
11.4
12.4
13.4
14.5
15.5
16.6
17.7
18.7
19.7
20.8
FS-75/1
FS-75/2
FS-75/3
FS-75/4
FS-75/5
FS-75/6
FS-75/7
FS-75/8
FS-75/9
FS-75/10
54 ~ 750
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
47 ~ 750
1.1
2.1
3.2
4.2
5.2
6.2
7.3
8.3
9.3
10.3
Freq. Range
Freq. Range
FS-75/11 FS-75/12 FS-75/13 FS-75/14 FS-75/15 FS-75/16 FS-75/17 FS-75/18 FS-75/19 FS-75/20
54 ~ 750
11.0
12.0
13.0
14.0
15.0
16.0
17.0
18.0
19.0
20.0
47 ~ 750
11.3
12.4
13.4
14.4
15.5
16.5
17.5
18.5
19.5
20.5
FS-86/6
FS-86/8
Freq. Range FS-86/3
FS-86/9 FS-86/11 FS-86/12 FS-86/14 FS-86/16 FS-86/17 FS-86/19
54 ~ 860
3.0
6.0
8.0
9.0
11.0
12.5
14.0
15.5
17.0
18.5
47 ~ 860
3.1
6.2
8.2
9.2
11.2
12.7
14.3
15.8
17.3
18.8
Specifications are subject to c hange without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV INDOOR AMPLIFIER 862 MHz 30 dB Amplifier
HA-30F
Features : Designed for CATV, MATV and SMATV RF signal distribution One Push-Pull hybrid amplification module provides maximum 30 dB gain with very low inter-modulation and harmonic distortion in HA-30F. High output level Wide band amplifications Input level and tilt equalizer continuously adjustable Built-in power supply and stabilizing circuit for direct AC powering Two test ports for convenient input and output signal monitoring without transmission service interrupted Both input and output ports equipped with surge protection devices against surge and atmospheric discharge The anodized aluminum housing for shielding and heat-sinking
Block Diagram ATT
EQ
IN
OUT
I/P Test Point
I/P Test Point 12VDC Power
Supply
CATV / MATV INDOOR AMPLIFIER 862 MHz 30 dB Amplifier Specifications : Description
HA-30F
RF Amplification Device Max. Gain
Push-Pull Hybrid Module dB
31 ¡ Ó1.5 (47 ~ 750 MHz) 30 ¡ Ó1.5 (750 ~ 862 MHz)
Flatness
dB
Ó1.5
Gain Control (adj)
dB
0 ~ 18 ¡ Ó3
Tilt Control (adj)
dB
0 ~ 18 ¡ Ó3
Noise Figure
dB
8.5 typ.
Return Loss
dB
16 typ. 12 min.
Output Level (Ref.)
104 dBuV flat 135 chs. NTSC *
Composite Second Order (CSO)
dB
-60 min.
Composite Triple Beat (CTB)
dB
-61 min.
Cross Modulation (X-MOD)
dB
-62 min.
Test Point
dB
-20 ¡ Ó2 (related to Input & Output)
Power Consumption
W
13
Power Supply (¡ Ó10%)
Vac
117, 60 Hz or 230, 50 Hz
Operating Temperature
-10 ~ +60
Connectors
"F" Female
Impedance
75
Dimensions (with connectors)
mm
228(L) x 136(W) x 54( H)
Net Weight
Kg
1.43
* for digital channels at 550 ~ 862 MHz , carriers are -10 dB lower relative to analog channels. ** Power supply voltage to be specified in order. Specifications are subject to change without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV INDOOR AMPLIFIER
550 MHz 30 dB/ 40 dB/ 50 dB Amplifier
HA-30C HA-40C HA-50C
Features : Designed for CATV, MATV and SMATV RF signal distribution One Push-Pull hybrid amplification module provides maximum 30 dB gain with very low inter-modulation and harmonic distortion in HA-30C. Two-stage amplification is designed in HA-40C and HA-50C High output level (126 dBV @ -60 dB IMA I/P 2 chs, or 106 dB V @ -57 dB IMA I/P 60 chs.) Wide band amplifications ( HA-30C works up to 550 MHz and HA-40 / 50C works up to 550 MHz without inter-band cuts) Input level and tilt equalizer continuously adjustable Built-in power supply and stabilizing circuit for direct AC powering Two test ports for convenient input and output signal monitoring without transmission service interrupted Both input and output ports equipped with surge protection devices against surge and atmospheric discharge The anodized aluminum housing for shielding and heat-sinking
Block Diagram ATT
EQ
IN
OUT
24VDC I/P Test Point
Power
Supply
O/P Test Point
CATV / MATV INDOOR AMPLIFIER
550 MHz 30 dB/ 40 dB/ 50 dB Amplifier Specifications : Model Number Frequency Range
HA-30C
MHz
Flatness
HA-50C
47 ~ 550
RF Amplification Device Max. Gain
HA-40C
Push-Pull Hybrid Module dB
32.5 1.5
43.5 1.5
51 1.5
dB
1.2
Gain Control (adj)
dB
0 ~ 20
Tilt Control (adj)
dB
0 ~ 20
Noise Figure
dB
7.5 typ.
Return Loss
dB
18 typ. 12 min.
Test Point
dB
-20 2 (compared to Input & Output)
Power Consumption
W
Power Supply ( 10%)
Vac
117, 60 Hz or 230, 50 Hz
Operating Temperature
C
-10 ~ +60
dBV
106 (at 60 ch, -54 dBIMD)
Max. Output
20
22
Connectors Impedance
"F" Female
Input & Output Port
Neon Tube or Surge Arrestor
Surge Protection Internal Fuse Dimensions (with connectors) Weight
75
0.8 A, 250 V, 6 x 32 mm mm
228(L) x 136(W) x 54( H)
Kg
1.43
Housing
Aluminum housing with 2 heat-sinker
* Power supply voltage to be specified in order. Specifications are subject to c hange without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan
25
CATV / MATV INDOOR AMPLIFIER CATV MDU Ampl ifier --- - 862 MHz 45 dB Gain
HAE-45F
Features : 862 MHz wide band amplifier for CATV, MATV application High output level Level control and slope control continuously adjustable Built-in power supply and stabilizing circuit for direct AC powering Two test ports for convenient input and output signal monitoring without transmission service interrupted Both input and output ports equipped with surge protection devices against surge and atmospheric discharge The aluminum housing for excellent heat-sinking and reliability.
Model Number System : HAE-45F Forward frequency: F -- 862 MHz Forward gain: 45 -- 45 dB gain Zinwell's new CATV MDU amplifier
CATV / MATV INDOOR AMPLIFIER CATV MDU Amp lif ier ---- 8 62 MHz 4 5 dB Gain Specifications : Model Number
HAE-45F
Frequency Range
MHz
47 ~ 862
dB
45 Ó2
Gain Control (adj)
dB
0 ~ 18
Tilt Control (adj)
dB
0 ~ 18
Noise Figure
dB
6.5
Return Loss
dB
16 typ. 12 min.
Gain
Output Level (Ref.)
100 dBuV flat 77 channels
Composite Second Order (CSO)
dB
-54 min.
Composite Triple Beat (CTB)
dB
-51 min.
Cross Modulation (X-MOD)
dB
-58 min.
Test Point
dB
-20 ¡ Ó2 (related to Input & Output)
Power Consumption
W
6
Power Supply (¡ Ó10%)
Vac
110, 60 Hz or 230, 50 Hz
Operating Temperature
-10 ~ +50
Connectors
"F" Female
Impedance
75
Dimensions (with connectors) Weight
mm
222(L) x 136(W) x 54( H)
Kg
1.4
* Power supply voltage to be specified in order. Specifications are subject to c hange without notice.
Block Diagram : ATT
EQ OUT
IN
Vcc I/P Test Point
Power Supply
O/P Test Point
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV PASSIVE DEVICES Attenuator
HAT-5 (10, 15, 20, 5U, 10U, 15U, 20U)
Features : Optimizing upstream signals or downstream signals to improve system performance when deploying cable modem application RFI shielding metal case with standard "F" connector "F" male / "F" female connectors complied to SCTE standards
Specifications : Description
Freq. (MHz)
Insertion
5 ~ 55
Loss
70 ~ 770
5 ± 1 dB
10 ± 1 dB
15 ± 1 dB
20 ± 1 dB
Description
Freq. (MHz)
HAT-5U
HAT-10U
HAT-15U
HAT-20U
Insertion
5 ~ 55
5 ± 1 dB
10 ± 1 dB
15 ± 1 dB
20 ± 1 dB
Loss
70 ~ 100
HAT-5
HAT-10
HAT-15
HAT-20
2 dB max.
3 dB max.
100 ~ 770
1.5 dB max.
Description
Freq. (MHz)
HAT-xx, xxU
Return Loss
5 ~ 55
10 dB min.
70 ~ 770
10 dB min.
Impedance Dimensions (with connectors)
75 13.5(D) x 51.5(L) mm
Weight
22 g
Specifications are subject to c hange without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2007 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV INDOOR AMPLIFIER 6 KV, 1 GHz Drop Amplifier with Active / Passive Return
s n o i t a c i f i c e p S y r a n i m i l e r P
HDA-xx-M 1 port series
Standard Package: 1. HDA Amplifier 2. AC/DC Adapter 3. 6 feet RG-59 Cable
Listed Power Supply 120 Vac: U L R
230 Vac: CE
Features :
1 GHz high quality 1-way drop amplifier Low noise, high isolation with excellent gain flatness Built-in passive or active return path Adapter and power inserter available for local or remote powering Zinc alloy die-casting housing making free from RFI and heat-sinking problem 6 KV ring wave surge protection SCTE compliance and CE compliance
Application Diagram : Local Powering
Remote Powering
(Option)
CATV / MATV INDOOR AMPLIFIER 6 KV, 1 GHz Drop Amplifier with Active / Passive Return
s n o i t a c i f i c e p S y r a n i m i l e r P
General Specifications : Description
Specification
Power Source
12 ~ 16 Vdc 300 mA
From power supply or cable powering
Power Consumption
250 mA max.
Screening Surge
Class B (According to EN50083-2)
Ring Wave*
0.5us 100KHz 6KV
ESD**
15 KV
Impedance
75
Connector
"F" Female
Dimensions
111.6 x 96.3 x 29.0 mm
Net Weight
220 g
* Surge applied to INPUT & OUT + PWR without DC INPUT.
** All ports must withstand a 15KV charge to the outer conduction of each port with no performance degradation. *** Apply with CW carriers and refer to the worst case channel.
HDA-R series Specifications : Forward Path
Model Number
HDA-R30-1-M
HDA-R42-1-M
MHz
47 ~ 1000
54 ~ 1000
dB
15 typ. 13.5 min.
15 typ. 13.5 min.
Return Loss
dB
18 typ. 16 min.
18 typ. 16 min.
Flatness
dB
1.0
1.0
Noise Figure
dB
4 typ. 5 max.
4 typ. 5 max.
Frequency Range Gain
Frequency Range
55.25/547.25
55.25/745.25
55.25/547.25
55.25/745.25
Output Level
87dBuV flat
84dBuV flat
87dBuV flat
84dBuV flat
Channel Loading
77ch NTSC
110ch NTSC
77ch NTSC
110ch NTSC
Distortion*
MHz
CSO
dBc
57
57
57
57
CTB
dBc
72
72
72
72
X-MOD
dBc
69
68
69
68
Model Number
HDA-R55-1-M
HDA-R65-1-M
MHz
70 ~ 1000
84 ~ 1000
dB
15 typ. 13.5 min.
15 typ. 13.5 min.
Return Loss
dB
18 typ. 16 min.
18 typ. 16 min.
Flatness
dB
1.0
1.0
Noise Figure
dB
4 typ. 5 max.
4 typ. 5 max.
Frequency Range Gain
Frequency Range
77.25/547.25
77.25/745.25
121.25/547.25
121.25/745.25
Output Level
87dBuV flat
84dBuV flat
87dBuV flat
84dBuV flat
Channel Loading
74ch NTSC
107ch NTSC
72ch NTSC
105ch NTSC
Distortion*
MHz
CSO
dBc
57
57
57
57
CTB
dBc
72
72
72
72
X-MOD
dBc
69
68
69
68
Return Path (Passive) Return Signal Frequency
MHz
5 ~ 30/ 42/ 55/ 65 (depending on order)
Insertion Loss
dB
1 typ. 1.6 max.
1 typ. 1.6 max.
Return Loss
dB
18 typ. 16 min.
18 typ. 16 min.
* Apply with CW carriers and refer to the worst case channel. Specifications are subject to change without notice.
CATV / MATV INDOOR AMPLIFIER 6 KV, 1 GHz Drop Amplifier with Active / Passive Return HDA-RA series Specifications :
s n o i t a c i f i c e p S y r a n i m i l e r P
Forward Path
Model Number
HDA-RA30-1-M
HDA-RA42-1-M
MHz
47 ~ 1000
54 ~ 1000
dB
15 typ. 13.5 min.
15 typ. 13.5 min.
Return Loss
dB
16 typ. 14 min.
16 typ. 14 min.
Flatness
dB
1.0
1.0
Noise Figure
dB
4 typ. 5 max.
4 typ. 5 max.
Frequency Range Gain
Frequency Range
55.25/547.25
55.25/745.25
55.25/547.25
55.25/745.25
Output Level
87dBuV flat
84dBuV flat
87dBuV flat
84dBuV flat
Channel Loading
77ch NTSC
110ch NTSC
77ch NTSC
110ch NTSC
Distortion*
MHz
CSO
dBc
57
57
57
57
CTB
dBc
72
72
72
72
X-MOD
dBc
69
68
69
68
Model Number
HDA-RA55-1-M
HDA-RA65-1-M
MHz
70 ~ 1000
84 ~ 1000
dB
15 typ. 13.5 min.
15 typ. 13.5 min.
Return Loss
dB
16 typ. 14 min.
16 typ. 14 min.
Flatness
dB
1.0
1.0
Noise Figure
dB
4 typ. 5 max.
4 typ. 5 max.
Frequency Range Gain
Frequency Range
77.25/547.25
77.25/745.25
121.25/547.25
121.25/745.25
Output Level
87dBuV flat
84dBuV flat
87dBuV flat
84dBuV flat
Channel Loading
74ch NTSC
107ch NTSC
72ch NTSC
105ch NTSC
Distortion*
MHz
CSO
dBc
57
57
57
57
CTB
dBc
72
72
72
72
X-MOD
dBc
69
68
69
68
Return Path (Active)
Return Signal Frequency Gain
MHz
5 ~ 30/ 42/ 55/ 65 (depending on order)
dB
10 typ. 9 min.
10 typ. 9 min.
Return Loss
dB
18 typ. 14 min.
18 typ. 14 min.
Flatness
dB
0.8
0.8
Noise Figure
dB
6 typ. 7 max.
6 typ. 7 max.
Output Level
Channel Loading Output Distortion
116 dBuV
116 dBuV
116 dBuV
116 dBuV
1ch
2chs
1ch
2chs
56
52
56
52
dBc
* Apply with CW carriers and refer to the worst case channel. Specifications are subject to change without notice.
Model Number System : HDA - R 42 - 1 - M
Mini housing 1 output port
Return/Forward Splitting Freq: 30: 30 / 47 MHz 42: 42 / 54 MHz 55: 55 / 70 MHz 65: 65 / 84 MHz R : With passive return RA: With active return
High quality 1 GHz CATV drop amplifier
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV INDOOR AMPLIFIER 6 KV, 1 GHz Drop Amplifier with Active / Passive Return
HDA-xx-N 1 port series
HDA-xx-N 2 ports series
HDA-xx-N 4 ports series
Standard Package: 1. HDA Amplifier 2. AC/DC Adapter 3. 6 feet RG-59 Cable
Listed Power Supply 120 Vac: U L R
230 Vac: CE
Features : 1 GHz high quality 1 / 2 / 4 -way drop amplifier Low noise, high isolation with excellent gain flatness Built-in passive or active return path Adapter and power inserter available for local or remote powering Zinc alloy die-casting housing making free from RFI and heat-sinking problem 6 KV ring wave surge protection SCTE compliance and CE compliance
Block Diagram Vcc
REGULATOR
DC IN
Vcc RF OUT/DC IN
RF IN
H L
H L
RF OUT RF OUT
RF OUT
CATV / MATV INDOOR AMPLIFIER 6 KV, 1 GHz Drop Amplifier with Passive Return General Specifications : Description
Specification
Power Source
12 ~ 16 Vdc 200 mA From power supply or cable powering
Power Consumption
130 mA max. (Passive Return) 200 mA m ax. (Active Return)
Screening Surge
Class B (According to EN50083-2) Ring Wave*
0.5us 100KHz 6KV 200A
ESD**
15 KV
Impedance
75
Connector
"F" Female
Dimensions
136.0 x 112.4 x 27.3 mm
Net Weight
390 g
* Surge applied to INPUT & OUT + PWR without DC INPUT. ** All ports must withstand a 15KV charge to the outer conduction of each port with no performance degradation.
Specifications : Forward Path Model Number
HDA-R( )-1-N
Frequency Range
MHz dB
Frequency Range
MHz
HDA-R( )-4-N
47 / 54 / 70 / 84 ~ 1000 (depending on order)
Number of Output Port Gain
HDA-R( )-2-N
1
2
4
15 typ. 13.5 min.
11.5 typ. 10 min.
8 typ. 6 min.
55.25/ 547.25
55.25/ 745.25
55.25/ 547.25
55.25/ 745.25
55.25/ 547.25
55.25/ 745.25
Output Level
27 dBmV flat
24 dBmV flat
24 dBmV flat
20 dBmV flat
20 dBmV flat
17 dBmV flat
Channel Loading
77ch NTSC
110ch NTSC
77ch NTSC
110ch NTSC
77ch NTSC
110ch NTSC
Distortion*
CSO
dBc
57
57
57
57
57
57
CTB
dBc
72
72
72
72
72
72
XMOD
dBc
69
68
69
68
69
68
Flatness
dB
1.0
Noise Figure
dB
4 typ. 5 max.
Return Loss
dB
Isolation (Out - Out)
dB
18 typ. 16 min. -
22 typ. 18 min.
22 typ. 18 min.
Return Path (Passive) Return Signal Frequency
MHz
5 ~ 30 / 42 / 55 / 65 (depending on order)
Insertion Loss
dB
Flatness
dB
1 typ. 1.6 max.
0.8
Return Loss
dB
18 typ. 16 min.
Isolation (Out - Out)
dB
-
4.4 typ. 5.2 max.
24 typ. 20 min.
*Measured with CW carries, signal analyzer and spectrum analyzer. References to the worst case channel. Specifications are subject to change without notic e.
Model Number System : HDA - R 42 - 2 - N New housing Number of output ports: 1: 1 port, 2: 2 ports, 4: 4 ports Return/Forward Splitting Freq: 3: 30 / 47 MHz, 42: 42 / 54 MHz, 5: 55 / 70 MHz, 6: 65 / 84 MHz R : With passive return RA: With active return High quality 1 GHz CATV drop amplifier
7.5 typ. 8.2 max.
24 typ. 20 min.
CATV / MATV INDOOR AMPLIFIER 6 KV, 1 GHz Drop Amplifier with Active Return Specifications : Forward Path Model Number
HDA-RA( )-1-N
Frequency Range
MHz
Number of Output Port Gain
dB
Frequency Range
HDA-RA( )-4-N
1
2
4
15 typ. 13.5 min.
11.5 typ. 10 min.
8 typ. 6 min.
55.25/ 547.25
55.25/ 745.25
55.25/ 547.25
55.25/ 745.25
55.25/ 547.25
55.25/ 745.25
Output Level
27 dBmV flat
24 dBmV flat
24 dBmV flat
20 dBmV flat
20 dBmV flat
17 dBmV flat
Channel Loading
77ch NTSC
110ch NTSC
77ch NTSC
110ch NTSC
77ch NTSC
110ch NTSC
Distortion*
MHz
HDA-RA( )-2-N 47 / 54 / 70 / 84 ~ 1000 (depending on order)
CSO
dBc
57
57
57
57
57
57
CTB
dBc
72
72
72
72
72
72
XMOD
dBc
69
68
69
68
69
68
Flatness
dB
1.0
Noise Figure
dB
4 typ. 5 max.
Return Loss
dB
Isolation (Out - Out)
dB
16 typ. 14 min. -
22 typ. 18 min.
22 typ. 18 min.
Return Path (Active) Return Signal Frequency
MHz
5 ~ 30 / 42 / 55 / 65 (depending on order)
Gain
dB
Return Loss
dB
18 typ. 14 min.
Flatness
dB
0.8
Noise Figure
dB
Isolation (Out - Out)
dB
Output Level Channel Loading Output Distortion
dBc
10 typ. 9 min.
6 typ. 7 max.
7 typ. 5.5 min.
9.5 typ. 10.5 max. 24 typ. 20 min.
-
3.5 typ. 2 min.
13 typ. 14 max. 24 typ. 20 min.
56 dBmV
56 dBmV
56 dBmV
56 dBmV
56 dBmV
56 dBmV
1ch
2chs
1ch
2chs
1ch
2chs
56
52
56
52
56
52
*Measured with CW carries, signal analyzer and spectrum analyzer. Ref erences to the worst case channel. Specifications are subject to change without notice.
Application Diagram : Local Power Supply
Remote Power Supply
(Option)
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV INDOOR AMPLIFIER Power Inserter for HDA Amplifier
HDA-PI
Features : Power inserter for HDA-Series 1 GHz drop amplifier All F-type IN/OUT connectors for convenient CATV applications Low insertion loss RF shielding zinc alloy die-casting case with nickel plated
Specifications : Description
Specification
Insertion Loss
0.6 dB typ. 1 dB max.
Isolation Return Loss DC Pass
60 dB typ. 5 ~ 862 MHz
18 dB min.
862 ~ 1000 MHz
23 dB min.
DC IN
÷ HAD
DC IN
÷ RX
12 ~ 16 Vdc 300 mA None
Hum Modulation (operating)
70 dB typ.
RFI Ingress
> 100 dB
Connectors
"F" Female
Impedance Dimensions (with connectors)
75 49(L) x 47(W) x 19( H) mm
Net Weight
42 g
Specifications are subject to change without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan
CATV / MATV INDOOR AMPLIFIER 70 ~ 770 MHz Drop Amplifier with Gain and Slop Control
HDA-RA5-1-20J-N
Features : The 1 GHz high quality 1-way drop amplifier Switchable return path modes: amplifier, pass, cut-off EQ switchable 0/5 dB 15 KV bi-wave surge protection Power adapter and power inserter available for local or remote powering Main board consisting of FR-4 glass fiber PCB and sophisticated SMT technology to achieve high stability Zinc alloy die-casting housing making free from RFI and heat-sinking problem
HDA-RA5-1-20J Block Diagram
Regulator
DC IN
Att EQ5dB 0dB IN
H L
H Amp
Pass Cut-off
L
OUT
Test Port
CATV / MATV INDOOR AMPLIFIER
70 ~ 770 MHz Drop Amplifier with Gain and Slop Control Specifications : HDA-RA5-1-20J-N
Model Number
Forward AMP. 1 Out
Reverse AMP.
70 ~ 770 MHz
5 ~ 55 MHz
Frequency Range
AMP : 12 ~ 17 dB Gain
20 ~ 25 dB
PASS : -2 dB typ. -4 dB min. CUT : -60 dB typ. -45 dB min.
Return Loss
8 dB min.
10 dB min.
Noise Figure
8 dB typ.
5.5 dB typ.
EQ Switch
0/ -5 dB
-
Frequency Range
55.25/ 547.25 MHz
Output Level
93 dBuV flat
120 dBuV
Channel Loading
75 ch NTSC
1 ch NTSC
Distortion*
-60 dB (CTB)
-62 dB (2nd order)
HUM Modulation Surge Resistance Withstand
-70 dB 15
KV, (1.2/ 50 us) for IN, OUT & Power Port
Power Consumption
230 mA / 12 VDC max.
Power Source
12 ~ 16 V DC 250 mA From power supply or cable powering
Connectors
"F" Female
Net Weight
360 g + (Adapter) 160 g
Impedance
75
* Measured with CW carriers, signal analyzer and spectrum analyzer. References the worst case channel. Specifications are subject to c hange without notice.
ZINWELL TRANSMISSION BUSINESS UNIT 7F, 512, Yuan Shan Rd., Chung Ho City, Taipei Hsien 235, Taiwan Tel: 886-2-2225-1929 Fax: 886-2-2225-1447 e-mail:
[email protected] http://www.zinwell.com.tw c 2008 ZINWELL Corporation All rights reserved. Printed in Taiwan