Pengoperasian Water Injection PlantFull description
calculate water treatment plant
Deskripsi lengkap
Schematic diagram of water filtration plant, showing all steps, screening, sedimentation through alum and clarifier, then sand filteration and then pumping to over head reservoir.
deals with hardness and water softening by lime-soda ash process. also includes information on indices..
Softening PointFull description
my reportFull description
To design a water treatment plant first and foremost thing is calculation/estimation of plant capacity in which plant has to run up to design period without trouble.
Design of water Treatment Plant-MandviDescription complète
P.S: Pass Karado does not entertain the short cuts to make engineering easy. So we have disabled the downloading. Pass Karado is just a forum to reduce information asymmetry which is prevalent in I...
P.S: Pass Karado does not entertain the short cuts to make engineering easy. So we have disabled the downloading. Pass Karado is just a forum to reduce information asymmetry which is prevale…Full description
J E P T
Manufacturers Man ufacturers & Sup Suppliers pliers of o f Wa Water ter Treatme Treatment nt Plant Pl ant
WATER SERVIC ICES
J E P T
Spares & Equi Equipm pment
Manufacturers Man ufacturers & Suppli Suppliers ers of o f Water Treat Treatment ment Plant Pl ant
Spares & Equi Equipm pmen ent t
WATER SERVIC ICES Water Wat er Treatment Treatment Plant
Spares
JEPT ASSOCIATES
Water Softening Plant JEPT Associates supplies an extensive and comprehensive range of Water Softening Plant. The presence of hardness salts (calcium and magnesium ions) in the make up water supplies to boilers, cooling and process waters can have a serious impact on their performance. Loss of heat transfer in boilers and poor cooling in re-circulating cooling systems results in an increase in both energy and water consumption, and an increase in operating costs. The reliable JEPT standard range effectively removes these hardness salts and provides a valuable return on your investment. Standard range: Model Model Model Model
132 - Water Softeners up to 5m3/hr 230/250 - Water Softeners up to 15m3/hr 360/LF - Normal-Flow Water Softeners up to 20m3/hr 360/HF - High-Flow Water Softeners up to 50m3/hr
The standard range of units provides service 50 m3/hour, and configuring the units in a provide a further increase in design flow
flow rates from 0.65m3/hour to duplex or triplex system will rates.
The water softeners have capacities which a total input hardness level of 200ppm
vary from 4.3m3 to 420m3 with expressed as calcium carbonate.
The water softeners use the well-proven "Ion the hard water ions of calcium and resultant water to service is typically less
Exchange" process to convert magnesium to sodium ions. The than 4 ppm total hardness.
JEPT Water Softeners have several different automatic plant regeneration:
control options for instigating
•
• •
Water meter control - regenerates after a specified volume of water by counting electrical pulses f rom the meter supplied with the softener Time-clock control - regenerates at regular pre-set time intervals Microprocessor Microproces sor Control System programmed for water hardness and flow rate
The softener vessels are of a seamless pressure vessel in GRP construction with moulded polyethylene inner and glass fibre reinforced wound outer shell for durability and long life. The control valves are of the hydraulic double piston multiport type. Valves can be "top mount" or "side mount" entry for increased flow capacity. The JEPT range of softening units have several options of salt/brining systems: Single brine tank
Combined salt and brine tank for higher salt usage bulk salt systems. Raw water break tanks, booster pump sets, level control systems and other ancillary equipment are available as standard. Typical Boiler Uses: Water Softner plants meeting sugar Industry requirements for treated boiler in put water Laundries. Boiler make up for low pressure boilers Brewing/soft drinks Blended for process waters in high hardness areas Dyeing Food processing Cooling tower make-up. *Services available Water Softner trouble shooting. -----------------------------------------------------------------------------------------------------------------------------
Dated:- 22-7-2011 Ref.#.WBR262k9
To, Mr. ------------------.
Subject: -
Quotation for water softening plant Capacity = 20m3/hr
Dear Sir, This refers to our discussion, and we are pleased to offer the below mention quotation. The plant will have the following specifications.
1. Filtration system Bag filter (to filter any water suspension) .
2. Softening Vessel Qty.
2 No. (one operational one stand by).
Flow Rate
20m3/hr.
Vessel Material
M.S inner fiber-glass coated.
Media
Cation exchange resin.
Bed-Height
40_44 ins.
3. Softener control valve Auto Control valve Time Base Automatic regeneration.
4. Skid Structure The unit will be skid mounted made of carbon steel frame,
Total Amount:-
Water Softening Plant RS:- 7,00,000/( excluding all taxes). As stated per-quotation above.
Terms and Conditions :-
1234-
50% payment in advance. 35% payment on delivery 15% payment on Successful running of plant. Time of delivery one month after receiving advance payment . 5- One year warrantee against manufacturing defects