Industrial Steam Turbines The comprehensive product range from 2 to 250 megawatts
Answers for energy.
A Full Range of World-class Industrial Steam Turbines Whatever your need for a prime mover, Siemens can provide you with versatile, reliable and proven industrial steam turbines. A world leader in steam turbine technology, with over 100 years of experience and continuous development, and a fleet of more than 20,000 installed turbines, we are a prime partner for your business.
Siemens oers a comprehensive range ofsteamturbinesfrom45 kWto1,200 MW, withtheexibilitytoaddressthespecic requirementsforyourapplication.For our range o predesigned steam turbines withapoweroutputfrom45 kWupto 10 MWandforlargesteamturbinesfrom 250 MWto1,200 MW,weofferseparate portolio brochures.
Type
Steam parameters up to:
Ourindustrialsteamturbinesmeetcus- tomer requirements or economic instal lation and operation as well as providing excellentexibilityforcomplexindustrial processes.So,whetheryouneedagenerator drive or power generation or a mechanicaldriveforcompressors,blowers andpumps,justtalktousandtogether we can select the turbine or turboset which is optimally suited to your needs.
Ofcoursewestrictlyadheretotheguidelines laid down in the quality standards ISO19001andISO14001.Notonlythe steamturbines,butalsoassociatedeldprovenhigh-techproductsareavailable rom the Siemens range. These include generators,instrumentationandcontrols, aswellasauxiliaryandancillarysystems.
Output (MW) 20
40
60
80
100
120
SST-100
65 bar, 480° C
SST-150
103 bar, 505° C
SST-200
110 bar, 520° C
SST-300
120 bar, 520° C
SST-400
140 bar, 540°C
SST-500
30 bar, 400°C
SST-600
140 bar, 540° C
SST-700
165 bar, 585° C
Dualcasing/reheatornon-reheat
SST-800
140 bar, 540° C
Centeradmission
SST-900
165 bar, 585° C
140
160
180
Doubleow
Singlecasing/non -reheatDualcasing/ reheat
250
Fields of application Siemens industrial steam turbines increase the efciency o power generation and improve the economy o industrial applications.
Industries • Chemistry • Food&Beverage • Independentpowerproducers • Manufacturingindustries • • • •
SST-100 (up to 8.5 MW)
SST-150 (up to 20 MW)
SST-200 (up to 10 MW)
SST-300 (up to 50 MW)
SST-400 (up to 65 MW)
SST-500 (up to 100 MW)
SST-600(upto100MW)
SST-700(upto175MW)
SST-800(upto150MW)
SST-900(upto250MW)
Mines,metalandcementplants Oilandgasindustry Papermills/wood-workingindustry Petrochemistry/Reneries
• Smelters/Steel • Sugarandethanolplants • Utilitiesandmunicipalities Applications • Biomasspowerplants • • • •
Captivepowerplants Cogeneration/CHP Combinedcyclepowerplants Districtheatingplants
• Geothermalplants • Heat-recovery • Mechanicaldrives • Ships/Offshore • Solarthermalplants • Wasteincinerationplants Main advantages • Highefciency • Highreliability/availability • Customizedprovensolutions • Compactdesign • Simpleinstallationandmaintenance
Industrial steam turbines The comprehensive Siemens product range from 2 to 250 megawatts
SST-100
SST-150
SST-200
up to 8.5MW TheSST-100isasingle-casingturbine,geared forgeneratordrive;pre-engineeredincluding bladingasacost-effectivesolution.Mainlyused or industrial applications.
up to 20MW TheSST-150isasingle-casingturbine,providing geareddrivetoa1,500or1,800rpmgenerator andpackagedinaskid-mounteddesign.For powergeneration,itprovideshighefficiency together with a very compact arrangement.
up to 10MW TheSST-200isasingle-casingturbine,geared or with direct drive suited to both generator and mechanicaldrives.Usedforindustryandpower generation applications.
Technical data
Technical data
Technical data
•Poweroutputupto8.5 MW •Inletpressureupto65bar / 945psi •Inlettemperatureupto480°C/895°F •Rotationalspeedupto7,500rpm •Exhaustpressure(backpressure) upto10bar /145psi •Exhaustpressure(condensing) upto1bar/ 14.5psi •Exhaustarea0.22m 2 /2.4sq.ft.
•Poweroutputupto20MW •Inletpre ssureupto103bar /1,495psi •Inletsteamtemperatureupto505°C /940 ° F •Rotationalspeedupto13,300rpm •Bleedupto25bar/365psi •Controlledextractionupto16bar/230psi •Exhaustpressure(backpressure) upto10bar /145psi •Exhaustpressure(condensing) upto0.25bar/ 3.6psi •Exhaustarea0.28–1.6m 2 /3.0–17.2sq.ft.
•Poweroutputupto10 MW •Inletpres sureupto110bar/ 1595psi •Inlettemperatureupto520° C /970° F •C ontrolledextractionupto16bar/ 230psi andupto350°C/560°F •Bleedupto60bar / 870psi •Exhaustpressure(backpressure) upto16bar /230psi •Exhaustpressure(condensing) upto0.25bar/3.6psi •Exhaustarea0.17– 0.34m2 /1.8– 3.7sq.ft.
Typical dimensions
Typical dimensions
Typical dimensions
Length8m/26ft. Width3.7m /12.1ft. Height3.4m/ 11.2ft.
Length12m/ 39ft. Width4m/13.1ft. Height5m/16.4ft.
Length4m/13.1ft.* Width2m/ 6.5ft.* Height2.5m/8.2ft.*
Features
Features
Features
•Backpressure/ condensingtype •Packageunitdesign •Radialexhaust •Simpledesign,rigidrotor •Oilsystemintegratedinbaseframe •Separateoilandsteampiping
•Backpressure/condensingtype •Packageunitdesign •P re-engineeredturbinemodules, modular peripherals •Singlecontrolledextraction •Radialexhaust •Separatedoilandsteampiping
•Backpressure/ condensingtype •Packageunitdesign •Extensivepre-design •High-speed,downward/upwardexhaust •Customizedsteampath •Shortdeliverytime
*turbineskidonly
SST-300
SST-400
SST-500
up to 50MW TheSST-300isasingle-casingturbine, gearedforgeneratordrive.Ithasacompact andflexibledesignwithahighdegreeof standardization.Usedforpowergeneration applications.
up to 65MW TheSST-400isasingle-casingturbine, gearedforgeneratordrive.Ithasacompact andflexibledesignwithahighdegreeof standardization.Usedforindustryandpower generation applications.
up to 100MW TheSST-500isasingle-casingturbine,gearedor withdirectdrive.Itissuitedtobothgenerator and mechanical drives to accommodate large volumeflows.Typicallyusedaslow-pressure casingintwo-cylinderapplications.
Technical data
Technical data
Technical data
•Poweroutputupto50MW •Inletpres sure120bar /1,740psi •Inlettemperature520°C / 970°F •Rotationalspeedupto12,000rpm •C ontrolledextractionupto45bar / 655psi andupto400°C/750°F •Bleedupto60bar /870psi •Exhaustpressure(backpressure) upto16bar /230psi •Exhaustpressure(condensing) upto0.3bar/ 4.4psi •Exhaustarea0.28–1.6m2 / 3.0– 17.2sq.ft.
•Poweroutputupto65 MW •Inletpressureupto140bar/ 2,030psi •Inlettemperatureupto540° C / 1,005° F •Rotationalspeed3,000–8,000rpm •C ontrolledextractionupto45bar/ 655psi andupto450°C/840°F •Bleedupto60bar / 870psi •Exhaustpressure(backpressure) upto25bar/ 365psi •Exhaustpressure(condensing) upto0.3bar/4.4psi •Exhaustarea1.3 – 3.0m2 /14.0 – 32.5sq.ft.
•Poweroutputupto100 MW •Inletpressureupto30bar / 435psi •Inlettemperatureupto400°C / 750° F •Rotationalspeedupto15,000rpm •Bleedupto2,atvariouspressurelevels •Exhaustarea2x0.175– 3.5m2 / 2x1.9– 24.8sq.ft.
Typical dimensions
Typical dimensions
Typical dimensions
Length12m/ 39ft. Width4m/13.1ft. Height5m /16.4ft.
Length18m / 59ft. Width8.5m / 28ft. Height5.5m/18ft.
Length19m/ 62ft. Width6m/20ft. Height5m/16.4ft.
Features
Features
Features
•Backpressure/ condensingtype •P re-engineeredturbinemodules, modular peripherals •Twocontrolledextractions •Radial/ axialexhaust •Adaptivestageupto16bar •Packageunitdesign •Customizedsteampath
•Backpressure/condensingtype •P re-engineeredturbinemodules, modular peripherals •Twocontrolledextractions,radial/ axialexhaust •Adaptivestageupto16bar •Semi-packageunitdesign •Customizedsteampath •Shortdeliverytime
•Double-flowcondensingturbine •Standardturbinemodules,modular peripherals •Throttle-controlled •Highlycustomized •Customizedsteampath
SST-600
SST-700
SST-800
up to 100 MW TheSST-600isasingle-casingturbine,geared or with direct drive; suited to both generator andmechanicaldrives.Usedfortailor-made applicationsformostcomplexprocessesin industry and power generation.
up to 175 MW TheSST-700isadual-casingturbineconsisting ofagearedHPmoduleandLPmodule.Used forpowergenerationapplications,especially in combined cycle and solar thermal power plants. Each module can be used independently or can be combined or the optimal coniguration.
up to 150MW TheSST-800isasingle-casingdirect-driveturbine with reverse low design or generator applications.Usedfortailor-madeapplications formostcomplexprocessesinindustryand power generation.
Technical data
Technical data
Technical data
•Poweroutputupto100 MW •Inletpressureupto140bar/ 2,030psi •Inlettemperatureupto540°C/1,005°F •Rotationalspeed3,000 –15,000rpm •D oublecontrolledextractionupto65bar/ 945psi •Bleedupto5,atvariouspressurelevels •Exhaustpressure(backpressure) upto55bar/800psi •Exhaustarea0.175m2 –3.5m2 / 1.9 – 38sq.ft.
•Poweroutputupto175 MW •Inletpressure(withreheat)upto 165bar/ 2,395psi •Inlettemperature(withreheat)upto 585°C/1,085°F •Reheattemperatureupto415° C / 780° F •Rotationalspeed3,000 – 13,200rpm •C ontrolledextractionupto40bar/580psi andupto415° C /780° F •Bleedupto7;upto120bar /1,740psi •Exhaustpressure(backpressure) upto40bar/580psi •Exhaustpressure(condensing) upto0.6bar/8.5psi •Exhaustpressure(districtheating) upto3bar/ 45psi •Exhaustarea1.7– 11m2 /18.3 –118sq.ft.
•Poweroutputupto150 MW •Inletpressureupto140bar/ 2,030psi •Inlettemperatureupto540° C /1,005°F •Rotationalspeed3,000 – 3,600rpm •D ouble-controlledextractionupto 45bar/ 655psi •Bleedupto6,atvariouspressurelevels •Exhaustpressurevacuumupto 14bar / 205psi •Exhaustarea1.1 – 5.6m2 /11.8 – 60.3sq.ft.
Typical dimensions
Typical dimensions
Typical dimensions
Length19m/62ft. Width6m/20ft. Height5m /16.4ft.
Length22m/73ft.* Width15m/59ft.* Height6m/20ft.*
Length20m/66ft. Width8.5m/28ft. Height6m/ 20ft.
Features •Backpressure/ condensingtype •Standardturbinemodules,modular peripherals •Innercasingforhighsteamparameters •Secondsteaminjectionpossible •Packageunitdesign •Radial/ axialexhaust •Highlycustomized •Customizedsteampath
Features
Features
•Backpressure/condensingtype •Pre-engineeredturbinemodules •Parallelarrangementpossible •Provensolutionforsolarthermalpowerplants •Simpleextractionincrossoverpipe •Axial / radialexhaust •Reheatapplications •Customizedsteampath
•Backpressure/ condensingtype •Standardturbinemodules,modular peripherals •Innercasingforhighsteamparameters •Axial/radialexhaust •Packageunitdesign •Highlycustomized •Customizedsteampath
* including condenser
SST-900 up to 250 MW TheSST-900isasingle-casingturbinefor 2-polegeneratorsforpowergenerationand industry.SST-900RHisadual-casingturbine or reheat applications.
Technical data •Poweroutputupto250MW •Inletpressure(withreheat)upto 165bar /2,395psi •Inlettemperature(withreheat)upto 585°C/1,085°F •Reheattemperatureupto580° C /1,075° F •R otationalspeed3,000 – 3,600rpm; HPupto13,200rpm(forreheat) •Bleedupto7;upto60bar/ 870psi •C ontrolledextractionupto55bar/800psi andupto480°C/895°F •Exhaustpressure(backpressure) upto16bar /230psi •Exhaustpressure(condensing) upto0.6bar /8.5psi •Exhaustpressure(districtheating) upto3bar/45psi •Exhaustarea1.7 – 11m2 /18.3–118sq.ft.
Typical dimensions Length20.5m / 67ft.* Width11m/36ft.* Height10m /33ft.*
* including condenser
Features •Backpressure/ condensingtype •Pre-engineeredturbinemodules •Twocontrolledextractions •Adaptivestageupto16bar •Butterflyvalveupto55bar •Axial / radialexhaust •Reheatapplications •Customizedsteampath
Publishedbyandcopyright©2009: SiemensAG Energy Sector Freyeslebenstrasse1 91058Erlangen,Germany SiemensAG Energy Sector Oil&GasDivision Wolfgang-Reuter-Platz 47053Duisburg,Germany SiemensAG Lutherstrasse51 02826Görlitz,Germany SiemensEnergyInc. 10730TelgeRoad Houston,Texas77095,USA Formoreinformation,pleasecontact ourCustomerSupportCenter. Phone:+491805247000 Fax: +491805242471 (Chargesdependingonprovider) E-mail:
[email protected] Oil&GasDivision OrderNo.E50001-G410-A101-V3-4A00 PrintedinGermany Dispo34806,c4bs7477SWS04093. Printedonelementarychlorine-free bleached paper. All rights reserved. Trademarksmentionedinthisdocument arethepropertyofSiemensAG,itsafliates, or their respective owners. Subject to change without prior notice. The inormation in this document contains general descriptions o the technical options available,whichmaynotapplyinallcases. The required technical options should thereore be specifed in the contact.
www.siemens.com/energy