SAUDI ARAMCO ID/PID - 3/01/05 - REV 0 (Standards Cutoff - August 2004) SAIC NUMBER
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS Skid for Haza Hazardous rdous Locations - Zone or DIV DIV 2 locationsMaterial Receiving PROJECT TITLE
SA IC-J -6019 WBS / BI / JO NUMBER
EQUIPMENT ID NUMBER(S)
EQUIPMENT DESCRIPTION
LAYOUT DRAWING NUMBER
REV. NO.
SCHEDULED TEST DATE & TIME
ACTUAL TEST DATE & TIME
DATE APPROVED
1-Oc t -05
QR NUMBER
INST
CONTRACTOR / SUBCONTRACTOR
EQPT CODE
SYSTEM ID.
PURCHASE ORDER NUMBER
PLANT NO.
EC / PMCC / MCC NO. QUANTITY INSP.
MH's SPENT
TRAVEL TIME
SAUDI ARAMCO USE ONLY SAUDI ARAMCO TIP NUMBER
SAUDI ARAMCO ACTIVITY NUMBER
SAUDI ARAMCO INSPECTION LEVEL
CONTRACTOR INSPECTION LEVEL
ITEM No.
ACCEPTANCE CRITERIA
REFERENCE
A
Doc um ent Rev iew and Certi fi cati on
A1
Review Quality Documentation for Material Receiving.
A2
Material identification Procedure reviewed and shall be implemented for all materials, parts and components, including partially fabricated assemblies.( Based on project specs, which define the length of tube and part number in the drawings)
Schedule "Q" Attachment Attachment lV Sec. 3.2
A3
New and Unused - Instrumentation Instrumentation materials shall shall be new new and unused. unused.
Schedule "G" Sec. 4.1
A4
As Designed Designed - Instrumentatio Instrumentation n materials materials shall be in accordance accordance with the Saudi Aramco-approved project-specific design drawings, diagrams, schedules, lists, databases, and associated documents. See Attachments Attachments 1, 2 and 3
Schedule "G" Sec. 4.1
A5
Free of Damage - Instrumentation material s shall be free of damage. All Incoming material shall be visually inspected for damage and conformance to all applicable inspection releases with Material Test Report (MTR).
Schedule "Q" Attachment Attachment lV Sec 7.1
A6
QC Before Installation - Instrumentation materials shall conform to all applicable requirements, standards, and specifications prior to release to be used as part of the work.
Schedule "Q" Attachment Attachment lV Sec 7.1
A7
Traceability - Instrumentation materials shall be traceable from the manufacturer and supplier through delivery, storage, fabrication, erection, installation, repair, modification and use.
Schedule "Q" Attachment Attachment lV Sec. 3.3
A8
Verify that the contractor or it's Saudi Aramco approved third party inspector performed the quality activities at the supplier and sub-supplier locations as required by the inspection level assigned for the materials and equipment identified in SAER-1972 Inspection Requirements.
Schedule Q Attachment Attachment llI Sec 1.2
A9
Vendor to provide usual warranty from the packaged unit manufacturer. The warranty to include all materials, workmanship and performance characteristics in accordance with his standard terms and conditions. Components supplied by the packaged unit vendor will include, but are not limited to field instruments, controls, valves, safety systems, prewired field interfaces, plant control system interfaces and electrical systems.
34-SAMSS-831 Sec. 1
A10
Inspection: The items manufactured to this specification (34-SAMSS831) are subject to verification by the Buyer's Inspection Representative per Saudi Aramco Inspection Requirement Form 175-340200, attached to the Purchase Order.
34-SAMSS-831, Sec. 10.2
A11
The Contractor to produce certification that the equipment shall operate continuously without any degradation and should comply with a minimum -maximum range of 10°C(50°F) to 35°C(95°F) in indoor Air conditioned or a range of 0°C (32°F) to 55°C (32°F) in outdoor sheltered and to a range of 0°C (32°F) to 65°C (149°F) ( in outdoor unsheltered conditions)
34-SAMSS-831, Sec. 5.1
Schedule Q, Att, IV, Sec. Sec. 3.1.
Page 1 of 14
WORK PERMIT REQUIRED?
PASS
FAIL
N/A
RE-INSP DA DA TE
SAUDI ARAMCO ID/PID - 3/01/05 - REV 0 (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS Skid for Haza Hazardous rdous Locations - Zone or DIV DIV 2 locationsMaterial Receiving PROJECT TITLE
SAIC NUMBER
SA IC-J -6019 WBS / BI / JO NUMBER
ITEM No.
ACCEPTANCE CRITERIA
REFERENCE
A12
Vendor to provide certification that the equipment complies the following: Humidity Indoor humidity design basis shall be 20% to 80% relative humidity. Outdoor design basis shall be 5% to 95% relative humidity (non condensing).
34-SAMSS-831, Sec. 5.2
A13
Contractor to provide certification that the equipment meets the severe dust and contaminants requirements detailed below: 5.3.1 Onshore Environment Usual airborne dust concentration is 1 mg/m³. During sandstorms, dust concentrations may reach 500 mg/m³. Particle size distribution is as follows: • 95% of all particles are less than 20 micrometers • 50% of all particles are less than 1.5 micrometers Elements present in dust include compounds of calcium, silicon, magnesium, aluminum, potassium, chlorides and sodium. When wetted (high humidity conditions) these compounds function as electrolytes and can result in severe corrosion. Other pollutants present in the atmosphere under the most extreme conditions are: H2S 20 ppm (vol/vol) Hydrocarbon 150 ppm (vol/vol) SO2 10 ppm (vol/vol) CO 100 ppm (vol/vol) NOx 5 ppm (vol/vol) O3 1 ppm (vol/vol)
34-SAMSS-831, Sec. 5.3.1
A14
Storage, Handli Handli ng, and Preservation
A15
The manufacturer's storage, handling and preservation instructions to be followed.
B
Schedule Q, Att, IV, Sec Sec 5.
General General Requirements
B1
All materials shall be suitable suitable for for the specified specified service, service, and the Vendor Vendor shall obtain a written approval from the Buyer for all selected materials in severe process services. All wetted parts in sour service shall conform to NACE MR0175 - 2002.
34-SAMSS-831 Sec. 9
B2
The Vendor shall submit a list of all selected instrument manufacturers, instrument model numbers and specification sheets for approval by the Buyer.
34-SAMSS-831 Sec. 9.1
B3
Electrical Requirements: All Electrical equipment intended for operation in locations classified under the requirements of NFPA 70, Article 500, 500, shall be listed or labeled labeled by any of the the agencies agencies listed in appendix 2 (Attachment 3 and 4)
34-SAMSS-831, Sec. 7.1
B4
Conduit sealing fittings shall be labeled or listed by UL, FM or CSA.
34-SAMSS-831, Sec. 7.1
C.
Material Material Requirements for instru ments, pipin g and tubin g/ Fittings
C1
Purchase Order and Instrument specification sheet criteria shall be confirmed and compared with instrument stainless steel tags / labels and nameplates, and shipment checked for damage, prior to acceptance of the shipment
Schedule Q, Att IV, Sec. Sec. 7.1.
C2
All process-connecte process-connected d instruments instruments shall shall be cast or or forged steel, stainless stainless steel or a suitable corrosion resistant alloy equal to or better than the ASTM specifications. specifications.
34-SAMSS-831, Sec. 9.1
C3
Cast iron shall not be used for hydrocarbon service, or for any flangemounted instrument.
34-SAMSS-831, Sec. 9.1
C4
Instrument enclosures shall be steel or copper free aluminum, suitable for the environmental conditions.
34-SAMSS-831, Sec. 9.1
Page 2 of 14
DATE APPROVED
1-Oc t -05
QR NUMBER
INST
CONTRACTOR / SUBCONTRACTOR
PASS
FAIL
N/A
RE-INSP DA DA TE
SAUDI ARAMCO ID/PID - 3/01/05 - REV 0 (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS Skid for Haza Hazardous rdous Locations - Zone or DIV DIV 2 locationsMaterial Receiving PROJECT TITLE
SAIC NUMBER
SA IC-J -6019 WBS / BI / JO NUMBER
ITEM No.
ACCEPTANCE CRITERIA
REFERENCE
C5
Enclosures for instruments in outdoor plant areas shall be NEMA Type 4 in accordance with NEMA ICS 6 and NEMA 250 or IEC 60529 Type IP 65.
SAES-J-902, Sec. 7.1
C6
The field junction box , in a Class I, Zone 2 location and in nonhazardous areas , shall be a single door NEMA Type 4X or IEC 60529 Type IP 66 box. The box construction shall meet the following requirements: 7.2.1 Type 316 stainless steel body, door and hardware. 7.2.2 Continuously welded seams, finished smooth. 7.2.3 Continuous stainless steel hinge with removable pin. 7.2.4 Stainless steel captive clamps. 7.2.5 Data/Print pocket on inside of door. 7.2.6 External mounting brackets. 7.2.7 Collar studs for mounting inside panel. 7.2.8 Ground stud for terminating A/C safety ground wire. 7.2.9 Painted steel panel (back-pan); in 'severe corrosive environments' a stainless-steel panel shall be used.
SAES-J-902, Sec. 7.2
C7
C8
C9
C10
Instrument enclosures and junction boxes having an internal volume exceeding 2,000 cm³ shall be provided with Type 300 Series stainless steel breather and drain fittings, or a combination breather and drain fitting. Instrument Piping and Tubing Process connections up to and including the first block valve (the root valve) shall comply with 01SAMSS-017, Table -1 (See Attachment -1). Piping and tubing materials downstream of the first block valve shall comply with check list items ( B14 to B16) / paragraphs : All threaded threaded fittings fittings shall be forged carbon steel steel or stainless stainless steel steel per ASME B16.11, B16.11, and be Class 3000 3000 for systems rated rated up to to and including including ANSI Class 900, 900, and Class 6000 for systems systems rated ANSI ANSI Class 1500. 1500. All threaded connections shall be tapered per ASME B1.20.1. The minimum size of auxiliary piping and tubing for mechanical equipment shall be 1/2-inch NPS with the exception of air compressor packages which shall be 3/8-inch NPS.
SAES-J-902, Sec. 7.3 34-SAMSS-831, Sec. 9.1
34-SAMSS-831, Sec. 9.1
01-SAMSS-017, Sec. 5.1.3
C11
All piping, tubing and and valves shall be adequately adequately supported supported and and fastened fastened in a manner which facilitates replacement, and prevents vibration. Refer to Drawing AB-036521 for valve bracing.(Attachment-2)
01-SAMSS-017, Sec. 5.1.4
C12
Unions are not permitted in pressurized lines carrying flammable or toxic fluids unless they are required for removal or assembly of the equipment and cannot otherwise be substituted by flanges..
01-SAMSS-017, Sec. 5.1.8
All piping systems systems shall shall be provided provided with vent vent valves valves at high points and and drain valves at low points. Horizontal runs in pressure piping shall slope C13 gradually towards drain points. The minimum slope of drain lines shall be 1:50.
01-SAMSS-017, Sec. 5.1.9
A block valve, valve, 3/4-inch 3/4-inch NPS minimum, minimum, shall be be installed in each instrument take-off connection and shall be located as close as feasible C14 to the line, vessel, or mechanical equipment. Thermocouples and thermometers are excluded from the 3/4-inch NPS minimum requirement.
01-SAMSS-017, Sec. 5.1.10
Pipe may be bent where necessary to achieve the desired configuration. Bending of the pipe shall conform to the following: Pipe bends shall have surfaces free of cracks and buckles. Flattening of the cross section of C15 bends shall not exceed 8 percent of the nominal pipe diameter. Bending procedures and required heat treatment shall be in accordance with ASME B31.3. B31.3.
01-SAMSS-017, Sec. 5.1.11 and Sec 6.2
Page 3 of 14
DATE APPROVED
1-Oc t -05
QR NUMBER
INST
CONTRACTOR / SUBCONTRACTOR
PASS
FAIL
N/A
RE-INSP DA DA TE
SAUDI ARAMCO ID/PID - 3/01/05 - REV 0 (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS Skid for Haza Hazardous rdous Locations - Zone or DIV DIV 2 locationsMaterial Receiving PROJECT TITLE
SAIC NUMBER
SA IC-J -6019 WBS / BI / JO NUMBER
ITEM No.
ACCEPTANCE CRITERIA
REFERENCE
C16
Tubing: Stainless steel tubing shall be seamless, annealed, minimum wall thickness 1.24 mm, per ASTM A269, Grade TP-316L. Instrument air tubing shall be ¼ inch, 3/8 inch, or ½ inch OD stainless steel. Wall thickness shall be 0.75 mm or larger.
34-SAMSS-831, Sec. 9.2.2.1
C17
Fittings: 316 stainless steel compression fittings shall be either Crawford Swagelok, Parker Hannifin A-Lok, Parker Hannifin Corp. CPI or Hoke Gyrolock. Any proposal to use fittings other than those listed above shall be reviewed by Supervisor, Instrumentation Unit, Process Instrumentation Division, P&CSD.
34-SAMSS-831, Sec. 9.2.2.2
C18
Flexible hoses shall be stainless steel armored, with integral connectors. The hose length shall not exceed 600 mm. The hose lining shall be suitable for the process and operating conditions.
34-SAMSS-831, Sec. 9.2.2.2
Valves and and Manifolds : Forged carbon steel valves shall conform to C19 ASTM A105, A105, Grade 2. Forged Forged stainless stainless steel valves valves shall comply comply with ASTM A182, A182, Grade F316.
34-SAMSS-831, Sec. 9.3
C20
Gate Valves Valves (Excludi ng th e Root Valve): Gate valves shall be forged steel, with ratings as required, but at least Class 800 at 454°C. Gate valves shall have 316 stainless steel trim and stem, solid wedge, reduced bore, renewable stellited seat, and a hand wheel. Furthermore, they shall be suitable for repacking under pressure. Gate valves shall have internal screw rising stems for services below 175°C. An outside screw and yoke design is required for services at and above 175°C.
34-SAMSS-831, Sec. 9.3.1
C21
Needle Valves: Needle valves shall be bar stock steel, with ratings as required, but at least Class 3000.
34-SAMSS-831, Sec. 9.3.2
Needle valves shall have 316 stainless steel trim, integral seat, and welded bonnet. Needle valves shall have internal screw rising stems. Manifolds: Manifolds for flow meter service shall have a rating Class 6000 at 95°C, or Class 4000 at 260°C. Manifolds shall have 316 C23 stainless steel body, bonnet, stem and seat, and teflon packing. Connections shall be ½ inch NPT female at oval flange surface. D. D. Instrumentation Requirements C22
D1
General power wiring, for circuits up to 600 V to ground and a maximum current rating of 15 A, shall be stranded copper; flame retardant PVC, XLPE or XLPO insulated; size 14 AWG; have an insulation minimum temperature rating of 90°C and shall comply with NFPA 70 or IEC 60502-1.
34-SAMSS-831, Sec. 9.3.1 34-SAMSS-831, Sec. 9.3.3
34-SAMSS-831, Sec. 7.1.1
Instrumentation signal wiring shall be stranded copper; flame retardant PVC, XLPE or XLPO insulated and shall have an insulation minimum temperature rating of 90°C. The minimum wire size shall be: • 16 AWG single twisted pair/triad from instruments to the nearest skid D2 mounted junction box. Cables carrying analog signals shall also be shielded. • 18 AWG for multi-twisted pair/triad cables from junction boxes to other junction boxes boxes or marshalling cabinets. cabinets. • 22 AWG for multi-conductor cable inter-cabinet wiring.
34-SAMSS-831, Sec. 7.1.1
D3
Specialty cables (e.g., High Temperature, communication, network cables) shall be certified by any of the agencies listed in Appendix 2.(Attachment 3)
34-SAMSS-831, Sec. 7.1.1
D4
Pair/triads of multi-twisted multi-twisted pair/triad control cables shall be numbered. numbered.
34-SAMSS-831, Sec. 7.1.1
D5
Except for thermocouple wiring, black and white are the preferred colors for pair conductors and black, white and red for triad conductors unless otherwise specified in the purchase order. Blue color insulation or jacket shall only be used for intrinsically safe installation.
34-SAMSS-831, Sec. 7.1.1
Page 4 of 14
DATE APPROVED
1-Oc t -05
QR NUMBER
INST
CONTRACTOR / SUBCONTRACTOR
PASS
FAIL
N/A
RE-INSP DA DA TE
SAUDI ARAMCO ID/PID - 3/01/05 - REV 0 (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS Skid for Haza Hazardous rdous Locations - Zone or DIV DIV 2 locationsMaterial Receiving PROJECT TITLE
ITEM No.
SAIC NUMBER
SA IC-J -6019 WBS / BI / JO NUMBER
ACCEPTANCE CRITERIA
REFERENCE
D6
Splices are not permitted in wiring. When wiring must be extended, connections shall be made via terminal blocks.
34-SAMSS-831, Sec. 7.1.1
D7
Terminals Wiring connections shall be made to channel (rail) mounted terminal blocks. These terminal blocks shall have tubular box clamp connector and compression bar or yoke for wire termination. More than two connections per terminal point are not allowed. If open screw type terminals are used, terminal lugs shall be ring tongue, compression type, with insulated sleeves.
34-SAMSS-831, Sec. 7.1.2
D8
Fused terminals shall be used for power distribution, alarm and shutdown systems.
34-SAMSS-831, Sec. 7.1.2
D9
All packaged packaged unit wiring, wiring, intended intended for for interface with plant wiring, shall shall be terminated in junction boxes.
34-SAMSS-831, Sec. 7.1.3
D10
Wire Tagging Interconnecting wires between skid mounted components and between skid mounted instruments and the skid termination panel shall be tagged. Each tag shall identify the device to which the opposite end of the wire is connected. Heat shrink or ferrule type wire tags with permanently embossed identification markings shall be used.
34-SAMSS-831, Sec. 7.1.4
D11
Provision for grounding the skid structure shall be made at diagonally opposite corners. The skid structure shall be designed to accommodate two-hole compression connector, for (2/0 AWG) copper conductor, at each corner.
34-SAMSS-831, Sec. 7.1.5
An identification tag or nameplate of 316 stainless steel shall be attached securely to the equipment with SS or Monel fasteners. The tag shall be marked with raised alphanumeric or die stamped with the following information: • Saudi Aramco Purchase Order number • D12 Manufacturer • Part/Model Number • Serial Number • Date of Manufacture • Mark/Tag Number The tag or nameplate shall be located so that the information can be read after installation of the equipment or components.
34-SAMSS-913, Sec. 10.3.2
Class I, Divisi Divisi on 2. In Class I, Division 2 locations, meters, instruments, and relays shall comply with 501.3(B)(1) through (B)(6). That is all meters, instruments, and relays, including kilowatt-hour meters, instrument transformers, resistors, rectifiers, and thermionic tubes, shall be provided with enclosures identified for Class I, D13 Division 1 locations. Enclosures for ClassI, Division 1 locations include explosion proof enclosures and purged and pressurized enclosures. Alternatively, Alternatively, equipment equipment shall shall be permitted permitted to be be marked to indicate indicate the temperature class for which it is suitable, using the temperature class (T Code) of Table 500.8(B).- See Attachment 4
Page 5 of 14
NEC Article 501.3(B)
DATE APPROVED
1-Oc t -05
QR NUMBER
INST
CONTRACTOR / SUBCONTRACTOR
PASS
FAIL
N/A
RE-INSP DA DA TE
SAUDI ARAMCO ID/PID - 3/01/05 - REV 0 (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS Skid for Haza Hazardous rdous Locations - Zone or DIV DIV 2 locationsMaterial Receiving PROJECT TITLE
SAIC NUMBER
SA IC-J -6019 WBS / BI / JO NUMBER
ITEM No.
ACCEPTANCE CRITERIA
REFERENCE
D14
Wiring Methods. In Class I, Division 2 locations, the following wiring methods shall be permitted: 1) Ensure that the conduit shall be rigid non-metallic conduit, elctrical metallic tubing, threaded rigid metal conduit, and joints shall be made up with at least five threads fully engaged. 2) Type MI cable shall be installed and supported in a manner to avoid tensile stress at the termination fittings and ensure that the fittings shall be listed for the location. 3) Type MC-HL cable listed for use in Class I Div. 1 locations with gas/vaportight continuous corrugated metallic sheath, an overall jacket of suitable polymetric material, separate grounding conductors in accordance with 250.122 and provided with termination fittings listed for the application. 4) Type ITC-HL cable listed for use in Class I Div. 1 locations, with a gas/vaportight continuous corrugated metallic sheath, an overall jacket of suitable polymetric material and provided with termination fittings listed for the application. NEC para. 501.4 (A)(1)(a-d) 5) Enclosed gasketed busways, enclosed gasketed wireways. 6) Type PLTC cable in accordance with the provisions of Article 725, or in
NEC Article 501.4(B)
D15
Flexible Cords, Class I, Divisi Divisi ons 1 and 2 . A flexible cord shall be permitted for connection between portable lighting equipment or other portable utilization equipment and the fixed portion of their supply circuit. The length of the flexible cord shall be continuous. Flexible cords are used shall be as follows: (1) Of a type listed for extra-hard usage (2) Contain, in addition to the conductors of the circuit, a grounding conductor complying with 400.23 (3) Connected to terminals or to supply conductors in an approved manner (4) Supported by clamps or by other suitable means in such a manner that there is no tension on the terminal connections (5) Provided with suitable seals where the flexible cord enters boxes, fittings, or enclosures of the explosion proof type
NEC Article 501.11
E.
Local Control and Alarm Display Cabinet Requirements Finish: The cabinet finish shall be per manufacturer's standard unless stated otherwise. The color of the coating shall be as specified in the Design: Vortex coolers, heat pumps or air conditioners may be used to reduce internal cabinet temperature with the prior approval of Supervisor,
34-SAMSS-831, Sec. 7.2.1 34-SAMSS-831, Sec. 7.2.2
E3
Drawings: Vendor shall provide wiring diagrams or wiring list showing termination strips and all electronic interconnections, with names and equipment/terminal identification. All spare terminals, terminal strips and wires shall appear on the vendor wiring drawings or list.
34-SAMSS-831, Sec. 7.2.3
E4
Indication Indication Li ghts , Pushbuttons and Switches Indication lights, pushbuttons and switches shall be of the oil tight, heavy duty type. Longlife type dated lamps or LED cluster lamps shall be used. Indication lights and pushbuttons shall have the following color: Red - abnormal, trip, shutdown, off, closed, emergency Yellow - (pre-) alarm Green normal, on, open, permissive start
34-SAMSS-831, Sec. 7.2.4
E5
Controllers and Instrumentation: The vendor shall ensure that all equipment, including digital controllers and displays are suitable for operation in the ambient conditions specified in Specification sheet. Controllers and displays shall be installed in locations where vibration is negligible. Digital displays shall be screened from direct sunlight.
34-SAMSS-831, Sec. 7.2.5
E1 E2
Page 6 of 14
DATE APPROVED
1-Oc t -05
QR NUMBER
INST
CONTRACTOR / SUBCONTRACTOR
PASS
FAIL
N/A
RE-INSP DA DA TE
SAUDI ARAMCO ID/PID - 2/19/05 - REV A (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS Skid for Haza Hazardous rdous Locations - Zone or DIV DIV 2 locationsMaterial Receiving
SAIC NUMBER
SA IC-J -6019
DATE APPROVED
1-Oc t -05
QR NUMBER
INST
At tac hm ent 1 Sheet 1 of 2 -- Materi Mat eri al s elec ti on and Jo in in g Met ho ds -01-SAMSS-017
Page 7 of 14
SAUDI ARAMCO ID/PID - 2/19/05 - REV A (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS Skid for Haza Hazardous rdous Locations - Zone or DIV DIV 2 locationsMaterial Receiving
SAIC NUMBER
SA IC-J -6019
DATE APPROVED
1-Oc t -05
QR NUMBER
INST
At tac hm ent 1 - Sheet 2 of 2 - Mater ial sel ect io n an d J oi ni ng Meth od s -01-SA MSS-017
Page 8 of 14
SAUDI ARAMCO ID/PID - 2/19/05 - REV A (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS Skid for Haza Hazardous rdous Locations - Zone or DIV DIV 2 locationsMaterial Receiving
SAIC NUMBER
SA IC-J -6019
DATE APPROVED
QR NUMBER
1-Oc t -05
Attac At tachm hm ent 2 -- Valve brac b racin ings gs st d DWG AB -036521 sht sh t 1 rev r ev 08
Page 9 of 14
INST
SAUDI ARAMCO ID/PID - 2/19/05 - REV A (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS Skid for Haza Hazardous rdous Locations - Zone or DIV DIV 2 locationsMaterial Receiving
SAIC NUMBER
SA IC-J -6019
DATE APPROVED
1-Oc t -05
QR NUMBER
INST
Attac At tachm hm ent 3 -- App ro val Agenc Ag encies ies for fo r Equi Eq ui pm ent in Hazardo us Area. Ar ea.
Page 10 of 14
SAUDI ARAMCO ID/PID - 2/19/05 - REV A (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS Skid for Haza Hazardous rdous Locations - Zone or DIV DIV 2 locationsMaterial Receiving
SAIC NUMBER
SAIC-J-6019
DATE APPROVED
1-Oc t -05
Attac At tachm hm ent 4 -- Elect ri cal Equip Equ ip ment men t Temper Tem peratu ature re clas c lass s NEC tabl e 500.8(B) 500.8(B)
Page 11 of 14
QR NUMBER
INST-
SAUDI ARAMCO ID/PID - 2/19/05 - REV A (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS General- Mechanic Mechanic al Equipm ent Skid- Zone or DIV 2 locations-Material Receiving Receiving (Does not apply for Custo m
SAIC NUMBER
SA IC-J -6019
DATE APPROVED
TESTING
QR NUMBER
INST
Attac At tachm hm ent 5 -- Temperat Temp eratur ure e senso sen sors rs in therm th ermow owell ell s , STD. Dwg. A B-036019 sht sh t 1 r ev 21
Page 12 of 14
SAUDI ARAMCO ID/PID - 2/19/05 - REV A (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS General- Mechanic Mechanic al Equipm ent Skid- Zone or DIV 2 locations-Material Receiving Receiving (Does not apply for Custo m
SAIC NUMBER
SAIC-J-6019
DATE APPROVED
TESTING
QR NUMBER
INST
Attac At tachm hm ent 6 -- Liqu Li quid id level lev el guag g uage e gl asses, ass es, ins i ns trum tr um ent pi pi ng detail det ails s l ib. ib . Dwg DB950046
At tach ment 4 -- Elect ri cal Equ ip ment Temp eratu re c las s NEC tabl e 500.8(B)
Page 13 of 14
SAUDI ARAMCO ID/PID - 2/19/05 - REV 0 (Standards Cutoff - August 2004)
SAUDI ARA MCO INSPECTION INSPECTION CHECKL CHECKLIS IS General- Mechanic Mechanic al Equipm ent Skid- Zone or DIV 2 locations-Material Receiving Receiving (Does not apply for Custo m
SAIC NUMBER
SAIC-J-6019
DATE APPROVED
1-Oc t -05
QR NUMBER
INST
Attac At tachm hm ent 7 -- Strai ght gh t pip p ipe e requi req uirem rem ents ent s for f or Orifi Ori fi ce , Vent uri ur i an d flo f low w nozzl n ozzles es Std. St d. Dwg Dw g AAA A-
Page 14 of 14