10b8b coding error in optical i nterface de vice Fault ID and name Usedinproducts Detectingunit
2004:EFaultId_OIC_LVDSRecAl LTE FCM,FCT
Source
OptIF
Meaning
The fibre cable has an interference; the data becomes faulty. A physical connection failure between the optical interface and the summing function (caused by bad circuit joints, for example).
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Effect
The cell operation is degraded. The optical interface loses its synchronization if the amount of errors exceeds the defined limit.
Reported alarms
7654CELLOPERATIONDEGRADED
LEDdisplay
Blinking red(optical interfaces) 1. Reset the RF Module behind the faulty optical interface by blocking/unblocking it. 2. If that does not clear the fault situation, replace the RF Module that causes the alarm.
Instructions
3. Reset the System Module. 4. If the System Module is the only source causing the alarm, or actions mentioned above do not clear the fault situation, Replace the System Module that causes the alarm.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d80580967eb2
©2014/6/4NokiaSolutionsandNetworks
2M external reference missing 1/1
2M external reference missing Fault ID and name
1899:EFaultId_2MExtRefMissAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FCM/FCT
Meaning
The reference clock monitoring has detected a loss of 2.048 MHz signal received from an external reference source, connected to Sync In interface of the System Module.
State
Start Cancel /
Unitstatus
Degraded;Working
Unit status attributes
Effect
Reported alarms
LEDdisplay
If other references are available, the synchronization reference source changes to another source. Tuning then follows this new reference. If other references are not available, the BTS master clock (OCXO) tuning is halted and the BTS synchronization drops to holdover mode. 7651 BASE STATION OPERATION DEGRADED 7652 BASE STATION NOTIFICATION Blinkingred Note! Perform the steps below in the listed order until the alarm disappears. 1. Check the cabling (connected to Sync In interface).
Instructions
2. Check if the 2.048 MHz reference source is working normally and the 2.048 MHz signal is available. 3. Replace the alarming module.
Related faults
BTS reference clock missing 3080: EFaultId_BtsReferenceClockMissing
Related information
Fault view
Id:0900d80580a46784
©2014/6/4NokiaSolutionsandNetworks
3GPP/AISG communication administratively disabled 1/1
3GPP/AISG comm unication administratively Fault ID and name
disabled
4142: EFaultId_Communication3gppAdministrativelyDisabledAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM,FCT
Source
ALD
Meaning
HDLC link is disabled for reporting Antenna Line or IUANT port.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LEDdisplay
Instructions
HDLC link will be disabled on reporting Antenna Line or IUANT port. 7652 BASE STATION NOTIFICATION 7654 CELL OPERATION DEGRADED STABLEGREEN To revert change, parameter Communication3gppEnabled should be enabled for reporting Antenna Line.
Related faults
Related information
Fault view
Id:0900d80580a38d7f
©2014/6/4NokiaSolutionsandNetworks
# autonomous reset as recovery action 1/1
# autonomous reset as recovery action Fault ID and name
52: EFaultId_UnitAutonomousResetAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FCM/FCT,FR,FSP
Meaning
The BTS tries to correct a fault situation by performing a recovery reset to a unit, the site or the BTS. In case of RF module reset in RF chaining configuration BTS resets also all RF modules that are further in chain.
State
Transient
Unit status
Working
Unit status attributes Effect
TheBTSisoperational.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablegreen Check the fault history and other active faults of the unit.
Instructions Note! This fault does not require any (special) actions. Related faults
Related information
Fault view
Id:0900d8058095b9e5
©2014/6/4NokiaSolutionsandNetworks
[User defined] 1/2
[User defined] 1400: EFaultId_ExtAl0 1401: EFaultId_ExtAl1 1402: EFaultId_ExtAl2 1403: EFaultId_ExtAl3 1404: EFaultId_ExtAl4 1405: EFaultId_ExtAl5 1406: EFaultId_ExtAl6 1407: EFaultId_ExtAl7 1408: EFaultId_ExtAl8 1409: EFaultId_ExtAl9 1410: EFaultId_ExtAl10 1411: EFaultId_ExtAl11 Fault ID and name
1412: EFaultId_ExtAl12 1413: EFaultId_ExtAl13 1414: EFaultId_ExtAl14 1415: EFaultId_ExtAl15 1416: EFaultId_ExtAl16 1417: EFaultId_ExtAl17 1418: EFaultId_ExtAl18 1419: EFaultId_ExtAl19 1420: EFaultId_ExtAl20 1421: EFaultId_ExtAl21 1422: EFaultId_ExtAl22 1423: EFaultId_ExtAl23 1424: EFaultId_ExtAl24 1425: EFaultId_ExtAl25
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM,FCT
Source
FCM, FCT
Meaning
High or low voltage on the external alarm line. The user specifies the fault text during commissioning.
State
Start Cancel /
Unit status
Working
Unit status attributes Effect
No actual effect to BTS functionality. This is user-specific.
Reported alarms LED display Instructions Related faults
Related information
Fault view
N/A [Userdefined]
[User defined] 2/2
Id:0900d805809549d6
©2014/6/4NokiaSolutionsandNetworks
Address mismatch in summing 1/1
Ad dr ess mi sm atc h in su mm in g Fault ID and name Usedinproducts Detectingunit
2019:EFaultId_Muksu_SsubMmAl LTE FCM,FCT
Source
FCM, FCT, FSP
Meaning
There is a baseband bus address mismatch in the summing. There are two possible causes: 1. A configuration error (two different baseband units functioning) - after an acknowledgement the fault returns. 2. Data corruption on the bus - appears once when unsynchronized data is sent by the baseband.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
RP3 traffic from the baseband is malfunctioning. The System Module operation is degraded.
Reported alarms
7651BASESTATIONOPERATIONDEGRADED
LEDdisplay
Blinkingred
Instructions
Check the antenna mapping to the local cells in the commissioning file.
Related faults
Baseband Bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d805809549e2
©2014/6/4NokiaSolutionsandNetworks
Antenna Carrier configuration failure 1/1
An ten na Carr ier co nf ig ur ati on fai lu re Fault ID and name Usedinproducts Detectingunit
6259: E FaultId_AntennaCarrierMessageFailed LTE FCM/FCT
Source
TX1-n/RX1-n
Meaning
Antenna carrier resources were not successfully set up during cell setup or cell deletion procedure because of failure of RX or TX resource. Affected cell might be not operational.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LED display
Affectedcellmightbenotfullyoperational. 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED N/A
Instructions
Perform the steps below in the listed order until the BTS fault disappears: 1.Check cables towards Radio Module 2.Reset Radio Module 3.Remove faulty unit
Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d80580954a1b
©2014/6/4NokiaSolutionsandNetworks
Antenna Line Device failure 1/1
An ten na Li ne Device fai lu re Fault ID and name Usedinproducts
3100: E FaultId_AntennaLineFailure LTE
Detectingunit
FSM,AntennaLineDeviceitself
Source
FR,MHA,TILT,EFIL
Meaning
The System Module or the device itself has detected an abnormal operation or a failure in the antenna line device.
State
Start Cancel /
Unit status
N/A
Unit status attributes
Effect
Depending on the reported alarms, the fault situation might have no impact on the operation (BASE STATION or CELL NOTIFICATION), the cell capacity might have decreased (CELL OPERATION DEGRADED), or the cell might not be operational at all (CELL FAULTY). 7652 BASE STATION NOTIFICATION
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED 7655 CELL NOTIFICATION
LED display
N/A Note: Perform the steps below in the listed order until the BTS fault disappears. 1. Check the antenna line and antenna line devices. Make sure that the antenna line connectors are in the right torque.
Instructions
2. Reset the alarming RF module by blocking/unblocking it. 3. Replace the faulty parts and/or devices along the antenna line. 4. Replace the RF Module. No connection to unit 10: EFaultId_NoConnectionToUnitAl Antenna line device HW failure 1847: EFaultId_HardwareErrorAl
Related faults
Communication failure 1806: EFaultId_CommunicationFailureAl Antenna Line Device Operation Failure 1871: EFaultId_BusyAl 1872: EFaultId_FormatErrorAl 1873: EFaultId_UnsupportedProcedureAl 1874: EFaultId_OutOfRangeAl
Related information
Fault view
Id:0900d805809549f2
©2014/6/4NokiaSolutionsandNetworks
Antenna line device HW failure 1/1
An ten na l in e dev ic e HW f ail ur e Fault ID and name
1847: EFaultId_HardwareErrorAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FR,TILT
Source
RX,TX,TILT,MHA,EFIL
Meaning
A hardware failure detected by an antenna line device. Usually, this is a permanent fault (the hardware is broken).
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
Reported alarms
LED display
The antenna line device is not working properly. The cell operation is degraded. 7652 BASE STATION NOTIFICATION 7654 CELL OPERATION DEGRADED Stable Green (7652) Alternating Red and Green (7654) 1. Block/unblock the Radio module to give a power-off reset to the antenna line devices.
Instructions 2. If that does not help, replace the antenna line device. Related faults
Antenna Line Device failure 3100: EFaultId_AntennaLineFailure
Related information
Fault view
Id:0900d805809549cd
©2014/6/4NokiaSolutionsandNetworks
Antenna Line Device Operation Failure 1/1
An ten na Li ne Device Operati on Fail ur e 1871: EFaultId_BusyAl Fault ID and name
1872: EFaultId_FormatErrorAl 1873: EFaultId_UnsupportedProcedureAl 1874: EFaultId_OutOfRangeAl
Usedinproducts Detectingunit
LTE FSM
Source
FlexiFilter,FA,AISGMHA,TILT
Meaning
The device is not working properly, the configuration is not valid, or a given parameter is incorrect.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
Reported alarms
Some antenna line device functions maynotwork properly. 7652 BASE STATION NOTIFICATION 7655 CELL NOTIFICATION
LED display
Blinking red (Filter), Stable green (other) 1. Check the functionality of the antenna line device.
Instructions
2. Check the compatibility between the antenna line device and the BTS. 3. Check that the given parameters are in the valid range.
Related faults
Antenna Line Device failure 3100: EFaultId_AntennaLineFailure
Related information
Fault view
Id:0900d805809549e5
©2014/6/4NokiaSolutionsandNetworks
Antenna line failure 1/1
An ten na li ne fai lu re Fault ID and name Usedinproducts Detectingunit
1836: E FaultId_ALOvercurrentAl LTE FlexiFilter,FR
Source
Antenna line
Meaning
Radio Module (60W RRH) or Filter (all others) has detected overcurrent on the antenna line. The antenna line might be damaged (short circuit) or some antenna line device is causing overload. All antenna line devices powered by the antenna line are out of order.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
The antenna line is not operating correctly. The cell capacity decreases.
Reported alarms
7654CELLOPERATIONDEGRADED
LED display
Alternating red and green (RF working, Antenna Line faulty)
Instructions
1. Check the antenna line and antenna line devices. Fix or replace the faulty parts/devices. 2. Alarm is cancelled only at RF Module reset or BTS reset.
Related faults
Related information
Fault view
Id:0900d805809549c4
©2014/6/4NokiaSolutionsandNetworks
Antenna line faulty 1/1
An ten na li ne fau lt y Fault ID and name
4045: E FaultId_AntennaLineFaultyAl
Usedinproducts
FlexiBTS,LTE
Detecting unit
FR
Source
Antenna line
Meaning
An alarm message has been received from the antenna line. The antenna line is faulty.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LEDdisplay
Instructions
The antenna line is not operating correctly. The cell is disabled. 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Periodicredandgreen 1. Check the antenna line and antenna line device that causes the alarm. 2. Fix or replace the faulty parts/devices.
Related faults
Related information
Fault view
Id:0900d80580954a3d
©2014/6/4NokiaSolutionsandNetworks
Antenna line operation degraded 1/1
An ten na li ne op erat io n deg rad ed Fault ID and name Usedinproducts Detecting unit
4046: E FaultId_AntennaLineDegradedAl LTE FR
Source
Antenna Line
Meaning
An alarm message has been received from the antenna line device. The antenna line operation is degraded.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
The antenna line is not operating correctly. The cell capacity decreases.
Reported alarms
7654CELLOPERATIONDEGRADED
LED display
Blinking red (RF working, Antenna Line degraded)
Instructions
1. Check the antenna line and antenna line device that causes the alarm. 2. Fix or replace the faulty parts/devices.
Related faults
Related information
Fault view
Id:0900d80580954a1a
©2014/6/4NokiaSolutionsandNetworks
Antenna link is down 1/1
An ten na li nk is do wn Fault ID and name
476: EFaultId_Rp3BusError
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSPC
Source
FSP, FSM
Meaning
Antenna (RP3) link is down: transmitter or receiver drops from synchronization.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
BTSisnotoperational orthecapacityisdegraded. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
LED display
Stable red (7650), Blinking red (7651)
Instructions
1. If the alarming module is the System Module (FSM1), restart BTS. 2. If that does not help, replace the alarming FSM.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface Failure in replaceable baseband unit 3003: EFaultId_FbiaFailureAl
Related information
Fault view
Id:0900d805809549f4
©2014/6/4NokiaSolutionsandNetworks
Baseband bus configuration of was rejected 1/1
Baseband bus configuration of was rejected Fault ID and name
1811: E FaultId_BbBus_ConfFailedAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT,FSP
Source
FSM/FCT,FSP,OptIF
Meaning
The baseband bus related configuration of was rejected by the HW SW, DSP or RF SW.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
This fault prevents the BTS from functioning. Depending on , some processing resources, some cells, or the whole BTS are out of order. 7650 BASE STATION FAULTY
Reported alarms
7651 BASE STATION OPERATION DEGRADED 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Stable red ( 7650); Blinking Red (7651)
Instructions
Replacethealarmingmodule.
Related faults
Baseband bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d805809549cf
©2014/6/4NokiaSolutionsandNetworks
Baseband Bus failure 1/2
Baseband Bus failure Fault ID and name
3020: E FaultId_BaseBandBusFailure
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM,FR
Source
FSM, FR
Meaning
The FlexiBTS has detected an abnormal operation or a failure in the BTS internal baseband bus. The failure cannot be attributed to a specific module but there are several possible fault sources.
State
Start Cancel /
Unit status
N/A
Unit status attributes
Effect
Depending on the reported alarms, the fault situation might have no impact on the operation (BASE STATION or CELL NOTIFICATION), the BTS capacity might have decreased (BASE STATION or CELL OPERATION DEGRADED, or CELL FAULTY), or the BTS might not be operational at all (BASE STATION FAULTY). 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
Reported alarms
7652 BASE STATION NOTIFICATION 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED 7655 CELL NOTIFICATION
LED display
N/A Note: Perform the steps below in the listed order until the BTS fault disappears. 1. Check the other active BTS faults and act accordingly. 2. Check the cables between the System Module and RF Module.
Instructions
3. Reset the RF Module and/or System Module, depending on the alarm source: a. Reset the RF Module by blocking/unblocking it. b. Reset the System Module by blocking/unblocking it. 4. Replace the alarming RF Module. 5. If the System Module is the source or replacing the RF Module does not clear the fault situation, replace the alarming System Module. Baseband bus configuration of was rejected 1811: EFaultId_BbBus_ConfFailedAl Not able to synchronize baseband bus with 1815: EFaultId_BbBus_SyncFailedAl RF BB Bus Synchronization Error 1904: EFaultId_FrRfBbBusSynchError RF BB Bus Configuration Error 1905: EFaultId_FrRfBbBusConfigError
Related faults
RF BB Bus Connection Transmission Error
Baseband Bus failure 2/2
_ BB bus reception error (summing device) 2016: EFaultId_Muksu_SMTimeOffAl BB bus transmission error 2017: EFaultId_Muksu_SRx10b8bAl BB bus message collision error 2018: EFaultId_Muksu_StxPortCollAl Address mismatch in summing 2019: EFaultId_Muksu_SsubMmAl
Related information
Fault view
Id:0900d805809549eb
©2014/6/4NokiaSolutionsandNetworks
BB bus message collision error 1/1
BB bus message collision error Fault IDa nd name Usedinproducts Detectingunit
2018: EFaultId_Muksu_StxPortCollAl LTE FCM,FCT
Source
FCM, FCT
Meaning
Routed baseband bus messages towards the connected module have collided; the data in the output baseband internal link is lost because the baseband bus is incorrectly configured.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
The RP3 traffic to the connected RF Module is malfunctioning. The BTS operation is degraded because some of the BTS resources are not available.
Reportedalarms
7650BASESTATIONFAULTY
LEDdisplay
Stablered 1. Check antenna mapping to the local cells in the commissioning file.
Instructions
2. Check the cables between the System Module and the connected module. 3. Replace the alarming module.
Related faults
Baseband Bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d805809549e1
©2014/6/4NokiaSolutionsandNetworks
BB bus reception error (summing device) 1/1
BB bus reception error (summing device) Fault ID and name Usedinproducts Detectingunit
2016:EFaultId_Muksu_SMTimeOffAl LTE FCM,FCT
Source
FSP, optIF
Meaning
The master frame in the received baseband bus frame is not in the correct place related to the internally generated master frame pulse. Either the frame has been set into the wrong place (PI delay) or the data itself is in the wrong place.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
The connection to the associated link is lost. The data is partly/completely lost. The worst-case fault effect can expand further from the cell level. This fault can prevent the BTS operation when the RF Module is needed for the required cell configuration. Fault is visible for the first radio in chain only. Fault 10 is sending for the other FRs, when pooling breaks because of the lost sync. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LEDdisplay
Stablered 1. Check the cables between the System Module and the connected module.
Instructions 2. Replace the unit that causes the alarm (System Module). Related faults
Baseband Bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d80580a56f77
©2014/6/4NokiaSolutionsandNetworks
BB bus transmission error 1/1
BB bus transmission error Fault ID and name Usedinproducts Detectingunit
2017: EFaultId_Muksu_SRx10b8bAl LTE FCM,FCT
Source
FCM, FCT
Meaning
A decoding error has been detected in the baseband internal link. The data packet is lost, or the content is corrupted. This situation is also triggered when the links do not synchronize with each other.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect Reportedalarms LEDdisplay
Data traffic to the connected RF Module is malfunctioning. BTS operation is faulty. 7650BASESTATIONFAULTY Stablered 1. Check the cables between the System Module and RF Module.
Instructions
2. Reset the System Module. 3. Replace the alarming module (System Module).
Related faults
Baseband Bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d805809549e0
©2014/6/4NokiaSolutionsandNetworks
Boot configuration inconsistency detected 1/1
Boot configuration inconsistency detected Fault ID and name Usedinproducts
4102: EFaultId_BootConfigurationInconsistencyAl FlexiBTS,LTE
Detectingunit
(FSMr2):FCM,(FSMr3):FCT
Source
FSMr2:FCM,FSPMCUFSMr3:FCT
Meaning
During SW update it was detected that configurations of active and passive SW in HW unit are same. Active and passive SW configuration are compared: - before SW download - during SW activation before active and passive SW switch - during start-up
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
LED display Instructions
Newly downloaded SW will overwrite active SW. Therefore, SW download and activation are not allowed. Currently active SW is still running. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED stable red (7650) , blinking red (7651) Replacethefaultyunit.
Related faults
Related information
Fault view
Id:0900d80580954a39
©2014/6/4NokiaSolutionsandNetworks
BTS Blocked 1/1
BTS Blocked Fault ID and name
50: EFaultId_BTSBlockedAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FCM(FSMr2),FCT(FSMr3)
Meaning
The BTS is blocked with BTS Site Manager. The purpose is to avoid fault indications that might be raised during a BTS maintenance task.
State
Start
Unit status
Working
Unit status attributes
Effect
The BTS does not send faults to the network management system (NMS) when the BTS is blocked. The fault cancellations are sent to the NMS. All cells are disabled.
Reportedalarms
7650BASESTATIONFAULTY
LEDdisplay
Stablegreen
Instructions
To cancel the fault, unblock the BTS. Unblocking the BTS causes a Site Reset (FSMr3) or BTS Reset (FSMr2).
Related faults
Related information
Fault view
Id:0900d80580954a52
©2014/6/4NokiaSolutionsandNetworks
BTS config error (not enough HW for LCR) 1/1
BTS config error (not Fault ID and name Usedinproducts Detectingunit
enough HW for LCR ) 1868: EFaultId_NotEnoughHwForLcrAl LTE FCM,FCT
Source
LCR
Meaning
RF Module cannot serve all cells commissioned to the RF module, there are not enough FSP resources for commissioned cells during BTS startup phase, or FSP/FBBx (Extension BaseBand unit, FBBA or FBBC) has failed (for example, power off or module crashing) to serve commissioned cells during runtime.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
TheBTScapacitydrops.
Reportedalarms
7653CELLFAULTY
LEDdisplay
Stablegreen RF module: Replace the single or dual PA RF module with a triple PA RF module. Alternatively, recommission the BTS with fewer cells. FSP: 1.Block and unblock the system module. 2.If that does not help, replace the system module.
Instructions
FBBx: 1.Ensure that all cables (Power and Baseband bus cables) have been connected to FBBx unit. 2.Block and unblock the system module. 3.If this does not help, replace the FBBx unit. Ensure that there has been installed enough DSP capacity (FSP/FBBx) to BTS if failure occurs in BTS start up phase. Alternatively, recommission the BTS with fewer cells.
Related faults
Configuration error: 3070: EFaultId_ConfigurationError
Related information
Fault view
Id:0900d80580a56f79
©2014/6/4NokiaSolutionsandNetworks
BTS configuration not supported 1/1
BTS configuration not supported Fault ID and name
4097: EFaultId_BtsConfNotSupportedAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCT
Source
FSP
Meaning
FSP does not support requested BTS configuration.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
BTS baseband processing power is decreased. If all FSPs are faulty BTS is not operational. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
LED display
Stable red (7650), Blinking red (7651)
Instructions
Note! Perform the steps below in the listed order until the fault disappears. 1. Change BTS configuration. 2. Reset BTS.
Related faults
Configuration error: 3070: EFaultId_ConfigurationError
Related information
Fault view
Id:0900d80580954a37
©2014/6/4NokiaSolutionsandNetworks
BTS file error 1/1
BTS file error Fault ID and name
1802: E FaultId_FileRequestFlashAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM[FSMr2]/FCT[FSMr3]
Source
FCM,FSP[FSMr2]/FCT,FSP[FSMr3]
Meaning
BPF file or optical interface FPGA file is invalid or missing. The FSP MCU SW file is invalid or missing.
State
Start
Unitstatus
Outoforder;Working
Unit status attributes
Working if there have been problems with the files in the SW package but the BTS is still operational. Out of order when the problems prevents the BTS from reaching the operational state.
Effect
TheBTSisnotoperating. 7650 BASE STATION FAULTY
Reported alarms
7651 BASE STATION OPERATION DEGRADED 7652 BASE STATION NOTIFICATION
LED display
Stable red (7650), Blinking red (7651), Stable green (7652) Note: Perform the following steps in the listed order until the fault disappears: 1. Use BTS Site Manager to perform a full commissioning to the BTS using the NetAct backup upload SCF file as template.
Instructions
2. Download two different software packages so that the faulty file is removed from the BTS. 3. Download the software again. 4. Replace the System Module.
Related faults
BTS internal SW management problem 3090: EFaultId_BtsInternalSwManagementProblem Failure in replaceable baseband unit 3003: EFaultId_FbiaFailureAl
Related information
Fault view
Id:0900d80580a38d81
©2014/6/4NokiaSolutionsandNetworks
BTS internal SW management problem 1/2
BTS internal SW management problem FaultI Da ndn ame
3090: EFaultId_BtsInternalSwManagementProblem
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
FSM,FCT,FR,FT,FSP,Faraday
Meaning
A software update to a m odule or sub-assembly has failed, or a corrupted SW file has been detected in the FLASH.
State
Start
Unit status
N/A
Unit status attributes
Effect
Depending on the reported alarms, the fault situation might have no impact on the operation (BASE STATION or CELL NOTIFICATION), the BTS capacity might have decreased (BASE STATION or CELL OPERATION DEGRADED) or the BTS might be not operational at all (BASE STATION FAULTY). 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
Reported alarms
7652 BASE STATION NOTIFICATION 7654 CELL OPERATION DEGRADED 7655 CELL NOTIFICATION
LED display
N/A Note: Perform the steps below in the listed order until the BTS fault disappears. 1. Check the other active BTS faults. If the ROM disk is corrupted, change the alarming module.
Instructions
2. Reset the RF Module and/or System Module, depending on the BTS fault source: a. Reset the RF Module by blocking/unblocking it. b. Reset the System Module by blocking/unblocking it. 3. Update and activate the SW to the BTS. 4. Check the SW files. 5. Replace the alarming module.
BTS SW download or activation failed 29: EFaultId_FileCorruptionAl 30: EFaultId_SwUpdateAl File corrupted in SW download 28: EFaultId_SwPackageAl Flash operation failure 214: EFaultId_FlashWrAl 215: EFaultId_FlashRdAl 216: EFaultId_FlashEraseAl 217: EFaultId_FlashDrvAl 218: EFaultId_FlashDbChksumAl Related faults
BTS file error
BTS internal SW management problem 2/2
1802: EFaultId_FileRequestFlashAl SW corrupted 1850: EFaultId_SwCorruptedAl 4029: EFaultId_SwCorruptedPermanentAl Unit SW download failed 6: EFaultId_SwDownloadAl BTS vendor specific file fault 6262: EFaultId_InvalidVendorSpecificFile Fault diagnostics rule file error 1866: EFaultId_RulesMissingAl 1867: EFaultId_RulesParsingAl
Related information
Fault view
Id:0900d805809549f1
©2014/6/4NokiaSolutionsandNetworks
BTS is uncommissioned 1/1
BTS is uncommissioned Fault ID and name
4030:EFaultId_NoCommDataAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCMFCT /
Source
FCM(FSMr2)/FCT(FSMr3)
Meaning
Commissioning file download has been started neither from BTS Site Manager, nor from NetAct during autoconfiguration. Autoconfiguration might not be enabled in NetAct, the license is missing or the commissioning file is not found.
State
Start
Unit status
Working
Unit status attributes Effect
TheBTSisnotcommissioned.
Reported alarms
7652BASESTATIONNOTIFICATION
LED display
N/A 1. Check in NetAct that autoconfiguration is enabled and the required license and commissioning file are available.
Instructions
2. Check the autoconnection/autoconfiguration information with BTS Site Manager. 3. Load the correct commissioning file to the BTS.
Related faults
Related information
Fault view
Id:0900d80580954a0c
©2014/6/4NokiaSolutionsandNetworks
BTS Master Clock tuning failure 1/1
BTS Master Clock tuning failure FaultID and name
1818: EFaultId_Ov_OscAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FCM/FCT
Meaning
The OCXO adjustment area is reaching its limit value. The DAC word value of the OCXO is lower than 205 or greater than 3891 (5% of the total adjustment area). The range for the DAC word is 0 - 4095.
State
Start Cancel /
Unit status
Degraded
Unit status attributes The BTS can operate properly for months or even a year when being in the 5% margin area, but eventually the DAC value reaches the adjustment limit (0 or 4095) and the OCXO cannot follow the synchronization reference signal beyond the limit. When the DAC value is 0 or 4095, the effect depends on the network synchronization setting defined in the BTS commissioning. Effects in FDD Frequency Synchronization mode: Assuming that the BTS reference signal has correct accuracy when the DAC value reaches the adjustment limit 0 or Effect
4095 (meaning the alarm indication is real, not caused by incorrect reference), the BTS air interface starts to drift from the correct value and after a while (weeks...months) the 3GPP accuracy limit is not met any more. Even in that stage the BTS might still be operational but the system performance might drop, affecting for example to handovers. Effects in FDD Phase Synchronization mode: When the DAC value reaches the adjustment limit 0 or 4095 the basic LTE system operation effects are the same as in Frequency Synchronization mode but the LTE feature(s) which require Phase Synchronization become(s) non-operational because the OCXO cannot adjust the phase synchronization any more.
Reported alarms
7651BASESTATIONOPERATIONDEGRADED
LEDdisplay
Blinkingred Note! Perform the steps below in the listed order until the fault disappears. 1. Check the other alarms of the BTS and FTM and act accordingly. 2. If there are no other synchronization-related alarms active, start the fast tuning with BTS Site Manager.
Instructions
3. Reset the site. Run fast tuning again. 4. Check the reference signal accuracy by measuring it with a frequency counter (note: requires a good timebase for the counter). The reference signal can be found from the Sync Out interface of the Flexi System Module, the required accuracy is +/-0.015ppm. If the reference accuracy is correct, run fast tuning. 5. If that does not help, replace the system module.
Related faults
Related information
Fault view
Id:0900d805809549c9
©2014/6/4NokiaSolutionsandNetworks
BTS reset required 1/1
BTS reset required Fault ID and name Usedinproducts Detectingunit
4001: EFaultId_BtsResetNeededAl LTE FSM
Source
FR, FSP
Meaning
The BTS detected an RF Module that cannot be put into use without a BTS reset. The RF Module type differs from the previous one or the RF module was not present during startup. FSP overheat occurred. Restoring the FSP normal temperature and resetting BTS is needed in order to put the card back into use. BTS startup: No FSP units detected by the time RP3 configuration starts. The BTS detected an FSP Module that cannot be put into use without a BTS reset. The FSP Module product code differs from the previous one or the FSP module was not present during startup.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
The new installed or failed HW resources are not available before the BTS has been reset. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LEDdisplay Instructions
Stablered 1. Reset (block/unblock)the BTS.
Related faults
Related information
Fault view
Id:0900d80580a3420c
©2014/6/4NokiaSolutionsandNetworks
BTS SW download or activation failed 1/1
BTS SW downl oad or activation Fault ID and name
failed
29: EFaultId_FileCorruptionAl 30: EFaultId_SwUpdateAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FlexiBTS:FCM(FSMr2)/FCT(FSMr3),FR
Meaning
The SW update to the BTS has failed. The error can be caused by a module reset during the SW update, a hardware problem in the module or a corrupted flash file system.
State
Start Cancel /
Unitstatus
Unit status attributes
Effect
Degraded;Working Working - if incompatible software version has been detected on the same unit and corresponding fault 23:EFaultId_IncompatibleSwVersionAl has been already reported. Degraded - in any other case. If the SW download to any HW unit failed, eNB continues operating with the currently running SW version. If the SW activation failed on FCM/FCT in the master FSM, eNB continues operating with the currently running SW version. If the SW activation failed on another HW unit (for example, RF unit), then: i. eNB restarts and operates with the new SW version installed ii. eventually, if eNB is integrated to NetAct, after the automatic recovery SW update, eNB restarts and operates with the old SW version installed 7651 BASE STATION OPERATION DEGRADED
Reported alarms
7654 CELL OPERATION DEGRADED 7655 CELL NOTIFICATION
LEDdisplay
Instructions
Related faults
Blinkingred(7651,7654) 1. Retry the SW update. 2. If other flash memory-related faults are active for the alarming module at the same time, replace the alarming module.
BTS internal SW management problem 3090: EFaultId_BtsInternalSwManagementProblem
Related information
Fault view
Id:0900d80580a3a674
©2014/6/4NokiaSolutionsandNetworks
BTS time not corrected 1/1
BTS time not corrected Fault ID and name
26:EFaultId_NtpTimeNotSetAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCMFCT /
Source
FCM/FCT
Meaning
The SNTP time cannot be fetched from the transport system (FTM) within the time limit.
State
Start Cancel /
Unit status
Working
Unit status attributes Effect
No real time available. Alarms, logs and all reports include incorrect time.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablegreen 1. Check the NTP setting.
Instructions 2. Check the stratum parameter on the NTP server. Related faults
Related information
Fault view
Id:0900d805809548b3
©2014/6/4NokiaSolutionsandNetworks
BTS vendor-specific file fault 1/1
BTS vendor-specific file fault Fault ID and name
6262: EFaultId_InvalidVendorSpecificFile
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FSM
Meaning
There was an opening, reading, or file content problem with a BTS vendor-specific file at BTS startup.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect Reportedalarms LEDdisplay
BTS startup is interrupted and the BTS is not operational. 7650BASESTATIONFAULTY Stablered Note: Perform the steps below in the listed order until the BTS fault disappears.
Instructions
Related faults
1. 2. 3. 4. 5.
Check the other active BTS faults. Reset the System Module by blocking/unblocking it. Update and activate the SW to the BTS. Check the SW files. Replace FSM.
BTS internal SW management problem 3090: EFaultId_BtsInternalSwManagementProblem
Related information
Fault view
Id:0900d80580954a20
©2014/6/4NokiaSolutionsandNetworks
Buffer over/underflow in clock crossing logic 1/1
Buffer ove r/unde rflow in clock crossing logic Fault ID and name Usedinproducts Detectingunit
2054: EFaultId_MuksuRxClkErrorAl LTE FCM
Source
OptIf
Meaning
Clock crossing buffer underflow or overflow in RX block and the received data might be not valid. The fault is an indication of either too large clock drift between received signal and internal clock or wrong RX rate setting.
State
Start
Unit status
Degraded
Unit status attributes Effect
Baseband bus RP3/RP3-01 traffic might work incorrectly. The cell operation is degraded.
Reported alarms
7654CELLOPERATIONDEGRADED
LED display
None 1. Check the status of the module behind the faulty link (power on, and so on).
Instructions 2. Check the alarming fiber connection. Related faults
Related information
Fault view
Id:0900d80580954a3e
©2014/6/4NokiaSolutionsandNetworks
Cell blocked 1/1
Cell blocked Fault ID and name
49: EFaultId_CellBlockedAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
LCR
Meaning
Theuserhasblocked the cell with BTS SiteManager.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
The BTS does not send any faults related to the blocked cell or the modules commissioned to the blocked cell to the network management system (NMS). The fault sending to BTS Site Manager is always enabled. The fault cancellations are always sent to the NMS. Calls through the blocked cell are transferred to another cell. It is not possible to establish new calls through the blocked cell.
Reportedalarms
7653CELLFAULTY
LEDdisplay
Stablegreen
Instructions
To cancel the fault, unblock the cell.
Related faults
Related information
Fault view
Id:0900d80580954a51
©2014/6/4NokiaSolutionsandNetworks
Cell power failure 1/1
Cell power failure FaultI Da ndn ame
4090: EFaultId_TxCarrierInputPowerLowAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
LCR
Meaning
Flexi Radio Module has detected low downlink carrier input power from the Flexi System Module.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect Reportedalarms LED display
Instructions
Thecellisdisabled. 7653CELLFAULTY None 1. Check the other active alarms and act accordingly. 2. If that does not help, block/unblock the system module. 3. FSMr2: If that does not help, replace the system module. FSMr3: If the faulty cell is on the baseband extension module, replace the extension module.
Related faults
Related information
Fault view
Id:0900d80580a467dc
©2014/6/4NokiaSolutionsandNetworks
Commissioning error: 1/1
Commissioning error: Fault ID and name
3060: EFaultId_CommissioningError
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM,FR
Source
FSM, FR, FT
Meaning
Some of the commissioning parameters are either missing or faulty, or there is a mismatch between them.
State
Start
Unit status
N/A
Unit status attributes
Effect
Depending on the reported alarms, the fault situation may have no impact on the operation (BASE STATION or CELL NOTIFICATION), the BTS capacity might have decreased (BASE STATION OPERATION DEGRADED), or the BTS might not be operational at all (BASE STATION FAULTY). 7650 BASE STATION FAULTY
Reported alarms
7651 BASE STATION OPERATION DEGRADED 7652 BASE STATION NOTIFICATION
LED display
N/A Note: Perform the steps below in the listed order until the BTS fault disappears.
Instructions
1. Check the commissioning parameters with the BTS Site Manager Commissioning Wizard. 2. Load the correct commissioning file to the BTS. Transmission parameters missing 1825: EFaultId_PublicIPmissingAl
Related faults
Invalid Configuration file 4036: EFaultId_InvalidConfigurationFileAl Incorrect radio network parameters 6252: EFaultId_FailureInNetworkPlanFile Radio master conflict 4038: EFaultId_RadioMasterConflictAl
Related information
Fault view
Id:0900d805809549ef
©2014/6/4NokiaSolutionsandNetworks
Communication failure 1/1
Communication failure Fault ID and name
1806: EFaultId_CommunicationFailureAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FCM/FCT,FSP,FTM,FR,FF,MHA,RET
Meaning
Communication with an application failed. It has not replied to the message that has been sent/resent to it.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
Some action inside the BTS is interrupted. The BTS does not operate normally. The fault is in the unit reported in the fault source field. 7650 BASE STATION FAULTY
Reported alarms
7651 BASE STATION OPERATION DEGRADED 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Stable red (7650) / (7653), Blinking red (7651) / (7654) 1. Make sure that the unit/module is properly connected. If the unit/module LED does not light up, the unit/module is faulty. Check the alarming unit/module.
Instructions 2. Check the fault history.
System Module failure 3000: EFaultId_SystemModuleFailure
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface Antenna Line Device failure 3100: EFaultId_AntennaLineFailure No connection to Flexi transport submodule 3511: EFaultId_NoConnectionToFtAl
Related information
Fault view
Id:0900d80580a4676a
©2014/6/4NokiaSolutionsandNetworks
Configuration error: 1/2
Configuration error: Fault ID and name
3070: E FaultId_ConfigurationError
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
FSM,FR,AntennaLine,LCR,LCG
Meaning
There is a compatibility problem in the BTS HW/SW versions or the HW/HW configuration. Another possibility is that there is a mismatch in the BTS configuration.
State
Start
Unit status
N/A
Unit status attributes
Effect
Depending on the reported alarms, the fault situation might have no impact on the operation (BASE STATION NOTIFICATION), the BTS capacity might have decreased (BASE STATION OPERATION DEGRADED or CELL OPERATION DEGRADED, or CELL FAULTY), or the BTS might not be operational at all (BASE STATION FAULTY). 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
Reported alarms
7652 BASE STATION NOTIFICATION 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED 7655 CELL NOTIFICATION
LED display
N/A Note: Perform the steps below in the listed order until the BTS fault disappears. 1. Check the installed HW/SW version compatibility and the HW compatibility with the current BTS configuration.
Instructions
2. Check that the BTS cell parameters from the Network management system match the BTS HW configuration (for example frequency, power). 3. Check the Network management system alarms for the alarming local cell (LCR). 4. Recommission the BTS to ensure that all parameters are correctly configured. Unit initialization failure 12: EFaultId_TcomConfigAl 4040: EFaultId_InitFaultManAl Unknown HW resource 94: EFaultId_UnknownUnitType Unit not supported by current BTS SW version 95: EFaultId_NotSupportedUnit Invalid frequency channel for the BTS HW 1807: EFaultId_InvalidFrequencyChannelForBTSHW
Related faults
Incoherency in cell configuration 1856: EFaultId_IncoherencyInCellConfigurationAl
Configuration error: 2/2
Incoherency with RF Modules 1857: EFaultId_IncoherencyWithRFModulesAl BTS config error (Not enough HW for LCR) 1868: EFaultId_NotEnoughHwForLcrAl Incoherency in cell configuration 4000: EFaultId_IncoherencyInConfiguration Incoherency In Cell Configuration 4044: EFaultId_IncoherencyCellConfigurationAl BTS configuration not supported 4097: EFaultId_BtsConfNotSupportedAl
Related information
Fault view
Id:0900d805809549f0
©2014/6/4NokiaSolutionsandNetworks
Cooling fan broken: 1/1
Cooling fan broken: Fault ID and name Usedinproducts Detectingunit
1933: E FaultId_FrFanBroken LTE FR/RFSW
Source
FAN, FAN_GROUP
Meaning
Fan(s)arenotrunning.
State
Start Cancel /
Unitstatus
Outoforder;Degraded
Unit status attributes
Not all fans failed: Module = Degraded, Fan group = degraded All fans failed: Module = Degraded, Fan group = Out Of Order
Effect
If the fans do not rotate as requested, there is a risk that the module temperature rises too high.
Reported alarms
7652BASESTATIONNOTIFICATION
LED display
FR module LED: Blinking red (7652, Fan Group Degraded), Blinking red (7652, Fan Group Out of Order). 1. Check if the fan connector is properly mounted.
Instructions 2. If that does not help, replace the fan module. Related faults
Fan failure 3050: EFaultId_FanFailure
Related information
Fault view
Id:0900d80580a38d85
©2014/6/4NokiaSolutionsandNetworks
Cooling fan broken 1/1
Cooling fan broken Fault ID and name
4078: EFaultId_FanBrokenAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCT
Source
Fan/Fan group
Meaning
Fan(s) are not running although the control is higher than 0.
State
Start Cancel /
Unitstatus
Outoforder;Degraded
Unit status attributes
Not all fans failed: alarming fan = out of order, fan group = degraded All fans failed: all fans and fan group = out of order
Effect
If the fans do not rotate as requested, there is a risk that the module temperature rises too high.
Reported alarms
7652BASESTATIONNOTIFICATION
LED display
Stable Red(Fan Group Out Of Order), Stable Yellow(FAN Group Degraded) 1. Check that the fan is not blocked.
Instructions
2. Check that the fan connector is properly mounted. 3. If that does not help, replace the fan.
Related faults
Fan failure 3050: EFaultId_FanFailure
Related information
Fault view
Id:0900d80580954a32
©2014/6/4NokiaSolutionsandNetworks
Cooling fan has reduced from the set speed 1/1
Cooling f an has reduced from t he set spee d Fault ID and name Usedinproducts Detectingunit
1934: E FaultId_FrFanReducedSetSpeed LTE FR/RFSW
Source
Fansupervision
Meaning
Fan(s) are rotating slower than requested.
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Module = Degraded, Fan group = degraded
Effect
If the fans do not rotate as requested, there is a risk that the module temperature rises too high.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stable/BlinkingYellow 1. Check if the fan connector is properly mounted.
Instructions 2. If that does not help, replace the fan module. Related faults
Fan failure 3050: EFaultId_FanFailure
Related information
Fault view
Id:0900d80580954a12
©2014/6/4NokiaSolutionsandNetworks
Cooling fan is over speeding 1/1
Cooling fan is over speeding Fault ID and name Usedinproducts Detectingunit
1935: E FaultId_FrFanOverSpeed LTE FR/RFSW
Source
RFSW
Meaning
Fan(s) rotatefaster than requested.
State
Start Cancel /
Unit status
Working
Unit status attributes Effect
If the fans rotate faster than requested, they cause unnecessary noise.
Reported alarms
7652BASESTATIONNOTIFICATION
LED display
None
Instructions
Replacethefanmodule.
Related faults
Fan failure 3050: EFaultId_FanFailure
Related information
Fault view
Id:0900d80580954a13
©2014/6/4NokiaSolutionsandNetworks
Cooling fan is over speeding 1/1
Cooling fan is over speeding Fault ID and name
4080: E FaultId_FanOverSpeedAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCT
Source
Fan/Fan group
Meaning
Fan(s) are running faster than requested.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
If the fans rotate faster than requested, unnecessary noise appears.
Reported alarms
7652BASESTATIONNOTIFICATION
LED display
None
Instructions
Replacethefan(s).
Related faults
Fan failure 3050: EFaultId_FanFailure
Related information
Fault view
Id:0900d80580954a34
©2014/6/4NokiaSolutionsandNetworks
Cooling fan speed decreased 1/1
Cooling fan speed decreased Fault ID and name
4079: E FaultId_CoolingFanSpeedDecreasedAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCT
Source
Fan/Fan group
Meaning
Fan(s) speed is deviating too much from the requested control.
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Alarming fan = degraded, fan group = degraded
Effect
If the fan(s) do not rotate as requested, there is a risk that the module temperature rises too high.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
StableYellow 1. Check if the fan is not blocked.
Instructions
2. Check if the fan connector is properly mounted. 3. If that does not help, replace the fan.
Related faults
Fan failure 3050: EFaultId_FanFailure
Related information
Fault view
Id:0900d80580954a33
©2014/6/4NokiaSolutionsandNetworks
Critical bit toggling error 1/1
Critical bit toggling error Fault ID and name
6701: E FaultId_CriticalBitTogglingError
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSP
Source
FSP
Meaning
Non correctable bit toggling error is detected in the critical DSP memory.
State
Start
Unit status
Working
Unit status attributes Effect
CriticalimpactonFSPoperation.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablegreen Note! Perform the steps below in the listed order until the fault disappears.
Instructions
1. Reset the System Module. 2. Replace the System Module.
Related faults
Related information
Fault view
Id:0900d80580954a3c
©2014/6/4NokiaSolutionsandNetworks
Difference between BTS master clock and reference frequency 1/2
Difference between BTS master clock and reference frequency Fault ID and name
9: EFaultId_DacWordChangeAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM
Source
FCM
Meaning
The reference frequency that the BTS master clock receives has changed by about 0.2 ppm or more (which equals the change magnitude of 204 DAC steps or more) during the measurement period, compared to the BTS master clock frequency. The cause of the alarm can be: 1. The reference frequency has changed due to a fault in the transmission network synchronization (which in turn is caused by an equipment fault or a setting error. Note that if the network synchronization malfunction lasts for a long time, the alarm is canceled when the BTS frequency reaches the faulty reference synchronization. The alarm can also be activated if the faulty reference synchronization is corrected and there is again the difference of 0.2 ppm or more. The alarm is canceled whenever the difference becomes smaller than 0.2 ppm. 2. The reference frequency fluctuates continuously due to a great deal of jitter/wander in the transmission network. The alarm is continuously activated/canceled (however, the alarming state might predominate). There is always some jitter/wander in the transmission network; the limits are defined in ITU-T G.823/824/825. 3. If the BTS integrated transport part receives the synchronization information via the 2.048 MHz synchronization input (external clock source), the alarm situation might be caused by a fault of that signal. In that case, the alarm behavior notifications listed with the Iub signal (see above) are also valid in this case. 4. There is an equipment fault in the BTS. The equipment fault is, however, not the most common reason. Normally, the reason is in the Iub/reference signal behavior (see the descriptions above).
State
Start Cancel /
Unit status
Working
Unit status attributes
Effect
This fault does not immediately affect the operations of the BTS, but it is a notification that the BTS master clock frequency deviates from the used reference frequency more than in normal circumstances. The BTS master clock tuning continues in spite of the alarm, but because the BTS master clock adjustment is quite slow to filter the instabilities of the reference clock interface, it takes some time (even several hours) before the BTS operations start to be affected.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Blinkingred Because there are several possibilities for the alarm activation, a BTS Clock Frequency History feature has been developed. You can access the stored history data via BTS Site Manager. You can use the history data as a tool for finding out the reason for the fault/alarm situation (for further instructions about the history feature, see the online help of BTS Site Manager). Depending on the possible reason, follow the instructions below: 1. In case of a fault in the transmission network synchronization, you must correct the network synchronization. The long-term accuracy of the Iub signal must be 0.015 ppm or better (check the correct Iub accuracy by measuring it). No actions on the BTS are necessary. 2. If the basic accuracy of the Iub signal is in order but there is too much instability, that is, the jitter/wander is outside the acceptable limits, you must correct the synchronization of the transmission network. The limits for the jitter/wander are defined in the ITU-T G.823/824/825. No actions on the BTS are needed. 3. In case of a BTS equipment fault, the location might be: Transport part: - First check the alarms of the TRS with BTS Site Manager and act accordingly. - If there are no alarms, check the TRS synchronization settings.
Difference between BTS master clock and reference frequency 2/2
Instructions
, . - If the alarm is still active after the fast tuning is finished, reset the site. If the problem does not disappear in a few minutes, reset the site. - If that does not help, replace the FCM unit. Note that if the reason is in the transmission network synchronization, replacing the faulty unit does not correct the situation. Furthermore, the alarm activity (frequent alarms/cancels) points to an instability in the transmission network, not to a fault in the unit. 4. After the fault situation has been cleared, you might need to tune the BTS master clock because the BTS master clock adjustment is quite slow. You can perform the tuning: - manually by changing the DAC word (during a site visit) - or with fast tuning, in which the BTS master clock is tuned in a few minutes automatically near the Iub reference (normal tuning takes care of the fine tuning). Note, however, that you should only use the fast tuning in case the Iub reference signal is known to be a good one. Otherwise the BTS frequency might be tuned into a totally incorrect value, causing serious problems in the network performance. Background information: The principle is that in the mobile network, the synchronization goes from S1 interface. But in reality that chain might be broken somewhere and, for example, when using leased lines, the BTS may take the reference synchronization from the transmission network of another operator. This does not harm the system if the synchronization of the leased line service provider is also accurate/stabile enough. The BTS uses the incoming synchronization signal as a reference for the Air interface, the accuracy requirement of which is set by 3GPP.
Related faults
Related information
Fault view
Id:0900d80580954a4c
©2014/6/4NokiaSolutionsandNetworks
Distributed site support not enabled 1/1
Distributed site support not enabled Fault ID and name Usedinproducts Detectingunit
4076: E FaultId_DistributedSiteSupportNotEnabledAl LTE FSM
Source
FR
Meaning
Long fiber between FSM and FR detected but Distributed Site feature not enabled (actDistributedSite = False). For FHCC modules fault means long fiber between FSM and customer's device.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LEDdisplay
Instructions
The Radio Module connected to this OptIFis not started. 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Blinkingred/NA Perform the steps below in the listed order until the fault disappears: 1. Either enable the parameter actDistributedSite or switch to a shorter fiber between FSM and FR. 2. Restart FSM.
Related faults
Related information
Fault view
Id:0900d80580a5701d
©2014/6/4NokiaSolutionsandNetworks
DSP overheated 1/1
DSP overheated Fault ID and name Usedinproducts Detectingunit
4101: EFaultId_DspOverheatingAl LTE FCT
Source
FSP
Meaning
DSP overheating was detected during DSP initialization.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
FSP operation is not possible due to overheated and disabled DSP. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
LED display
Stable red (7650), Blinking red (7651)
Instructions
1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the alarming FSP module.
Related faults
Temperature alarm 3040: EFaultId_TemperatureAlarm
Related information
Fault view
Id:0900d80580954a38
©2014/6/4NokiaSolutionsandNetworks
Failure during cell activation 1/1
Failure during cell activation Fault ID and name Usedinproducts
6267: EFaultId_CellActivationFailedAl LTE
Detecting unit
FCM [FSM Rel2] / FCT [FSM Rel3] / CC&T [FQGA]
Source
LCR
Meaning
Cell activation procedure failed because of processing error of cell configuration data. The corresponding cell cannot be enabled.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect Reportedalarms LED display
BTS continues to operate with remaining cells on air or goes to IntegratedToRAN state if there are no more "enabled" cells left. 7653CELLFAULTY N/A 1) Try to block/unblock the cell.
Instructions
2) Try to block/unblock FR module. 3) If it does not help, reset BTS.
Related faults
Related information
Fault view
Id:0900d80580954a30
©2014/6/4NokiaSolutionsandNetworks
Failure in connection between BTS and iOMS or 3rd party tool 1/1
Failure in connection between BTS and iOMS or 3rd p arty tool Fault ID and name Usedinproducts Detectingunit
6261: E FaultId_TraceConnectionFaultyAl LTE FCM/FCT
Source
FCM
Meaning
Failure in Trace connection between BTS and iOMS or 3rd Party Tool.
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Effect
In case of Subscriber trace activation, if the failed trace connection was to be used for sending the Trace Reports, then the BTS considers the trace activation for that subscriber as failed. In case of cell trace and interface trace, if the failed trace connection was to be used for sending the Trace Reports, then the BTS does not start tracing until the trace connection is established successfully.
Reported alarms
7651BASESTATIONOPERATIONDEGRADED
LED display Instructions
N/A Check the connection with iOMS/3rd Party tool.
Related faults
Related information
Fault view
Id:0900d80580954a1c
©2014/6/4NokiaSolutionsandNetworks
Failure in optical RP3 interface 1/2
Failure i n opt ical RP3 interface Fault ID and name Usedinproducts Detectingunit
3030: E FaultId_FailureInOptical_Rp3Interface LTE FSM,FR
Source
FSM, FR
Meaning
The FlexiBTS has detected an abnormal operation or a failure in an optical RP3 interface between two modules. The failure cannot be attributed to a specific module but there are several possible fault sources.
State
Start Cancel /
Unit status
N/A
Unit status attributes
Effect
Depending on the reported alarms, the fault situation might have no impact on the operation (BASE STATION NOTIFICATION) or the BTS capacity might have decreased (BASE STATION OPERATION DEGRADED or CELL OPERATION DEGRADED, or CELL FAULTY) or the BTS might not be operational at all (BASE STATION FAULTY). 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
Reported alarms
7652 BASE STATION NOTIFICATION 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
N/A Note: Perform the steps below in the listed order until the BTS fault disappears. 1. Check the other active BTS faults and act accordingly. 2. Check the cables between the System Module and RF Module. Note that dirty optical connectors may cause the signal level to drop too low.
Instructions
3. Depending on the fault source, reset the RF Module and/or System Module by blocking/unblocking it. 4. Replace the alarming module's Small Form Factor Pluggable (SFP). Check also the SFP in the other end and replace it if needed. 5. Replace the alarming RF Module. 6. If the System Module is the only alarming source or replacing the RF Module does not clear the fault situation, replace the alarming System Module. No connection to unit 10: EFaultId_NoConnectionToUnitAl Frame Clock Missing 1903: EFaultId_FrFrameClockMissing Communication failure 1806: EFaultId_CommunicationFailureAl Module Clock Faulty 1926: EFaultId_FrModuleClockFaulty Optical Interface faulty 2000: EFaultId_OIC_TxAl 2001: EFaultId_OIC_PresAl Receiving failure in Optical Interface 2002: EFaultId_OIC_RxAl
Failure in optical RP3 interface 2/2
Related faults
Optical Interface Data/Control/Ethernet Buffer Full 2006: EFaultId_OIC_DBRxFullAl 2007: EFaultId_OIC_DBTxFullAl 2008: EFaultId_OIC_CBRxFullAl 2009: EFaultId_OIC_CBTxFullAl 2010: EFaultId_OIC_EBFullAl OIC MCU Buffer Full 2011: EFaultId_OIC_MCUBFullAl Frame clock deviation fault 2014: EFaultId_Muksu_SFCRCompDevAl Frame number synchronization error in optical interface 2047: EFaultId_OIC_FrSyncLostAl RP3-01 link conflict 4039: EFaultId_Rp301LinkConflictAl Missing RP3-01 link 4064: EFaultId_MissingRp301LinkAl Loss of primary Opt IF 4161: EFaultId_LossOfPrimaryOptIfAl
Related information
Fault view
Id:0900d80580a5e118
©2014/6/4NokiaSolutionsandNetworks
Failure in replaceable baseband unit 1/2
Failure in replaceable baseband unit Fault ID and name
3003: EFaultId_FbiaFailureAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
FBB
Meaning
The BTS has detected an abnormal operation or a failure in the BTS replaceable baseband unit.
State
Start Cancel /
Unit status
N/A
Unit status attributes
Effect
Reported alarms
LED display
Depending on the reported severity, the BTS capacity might have decreased (BASE STATION OPERATION DEGRADED), or the BTS might not be operational at all (BASE STATION FAULTY). 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED N/A Note: Perform the steps below in the listed order until the BTS fault indication disappears. 1. Check the other active BTS faults and act accordingly.
Instructions
2. Check if the plug-in type baseband unit is installed correctly. 3. Reset the alarming baseband unit. 4. Replace the alarming baseband unit. No connection to unit 10: EFaultId_NoConnectionToUnitAl POST test failed 69: EFaultId_Post_test_failedAl Unknown HW resource 94: EFaultId_UnknownUnitType Flash operation failure 214: EFaultId_FlashWrAl 215: EFaultId_FlashRdAl 216: EFaultId_FlashEraseAl 217: EFaultId_FlashDrvAl 218: EFaultId_FlashDbChksumAl BTS file error 1802: EFaultId_FileRequestFlashAl 1803: EFaultId_FileParsingFailedAl
Related faults
Baseband bus configuration of was rejected 1811: EFaultId_BbBus_ConfFailedAl
Failure in replaceable baseband unit 2/2
Not able to synchronize baseband bus with 1815: EFaultId_BbBus_SyncFailedAl BB bus reception error (summing device) 2016: EFaultId_Muksu_SMTimeOffAl Address mismatch in summing 2019: EFaultId_Muksu_SsubMmAl Antenna link is down 476: EFaultId_Rp3BusError Unit SW download failed 6: EFaultId_SwDownloadAl SRIO chain configuration was rejected 4015: EFaultId_Srio_ConfFailedAl Master unit has lost connection to the slave unit 4019: EFaultId_KeepAliveStatusErrorAl FSP overheating 4077: EFaultId_FspOverheatingAl
Related information
Fault view
Id:0900d80580954a1e
©2014/6/4NokiaSolutionsandNetworks
Failure in trace session 1/2
Failure in trace session Fault ID and name Usedinproducts Detectingunit
6263: EFaultId_TraceSessionAl LTE FCM/FCT
Source
FCM
Meaning
Failure has occurred during activation/deactivation of Trace Session (Subscriber trace or Cell trace or Interface trace session). In case of Subscriber trace, the possible reasons are: Subscriber Trace feature has not been enabled at the BTS. - Id used for the subscriber trace session is already in use for another active subscriber trace session. - Count of subscriber trace sessions at the BTS has reached the maximum number of subscriber trace sessions supported by the BTS (which is 60). - Handover at BTS is ongoing for the UE to be traced In case of Cell/Interface trace, the possible reasons are: - Cell Trace feature has not been enabled at the BTS. - Id used for the cell/interface trace session is already in use for another active cell/interface trace session. - Count of cell and interface trace sessions at the BTS has reached the maximum number of cell and interface trace sessions supported by the BTS (which is 12).
State
Transient
Unit status
Working
Unit status attributes Effect
Trace session (for Subscriber/cell/interface) cannot be activated/deactivated.
Reported alarms
7652BASESTATIONNOTIFICATION
LED display
N/A For failure in Subscriber trace session activation/deactivation, based on the error cause provided as part of the additional info for the alarm raised, following needs to be done: - "Subscriber & Equipment Trace feature not enabled": Enable the subscriber trace feature at BTS. Any events corresponding to the failed subscriber trace and any other subscriber traces started later, which need to be recorded, will be recorded at BTS after the feature has been enabled. - "trace reference in use, trace cannot be started": This problem is out of scope to be fixed at BTS and is scope of NMS(Network Management System) used to activate the subscriber trace. The error means that there is already an active subscriber trace at BTS using the same Trace Reference Number. Possible solution is to try deactivating all subscriber traces and activating them again. - "max number of UE trace session reached, trace cannot be started": This problem is out of
Instructions
scope to be fixed at BTS and is scope of NMS(Network Management System) used for subscriber trace activation. This error indicates that already 60 active subscriber trace sessions (which is the maximum number of active subscriber traces supported at BTS at any point in time) has already been reached at BTS. Try to stop an already active subscriber trace session at NMS before activating any new subscriber trace(s). - "Trace session cannot be started because of ongoing handover for the UE" OR "Trace session cannot be stopped because of ongoing handover for the UE": This problem is out of scope to be fixed at BTS. This problem is transient. Possible solution is to retry activation of
Failure in trace session 2/2
the failed subscriber trace at NMS. For failure in Cell/Interface trace session activation/deactivation, based on the error cause provided as part of the additional info for the alarm raised, following needs to be done: - "Cell trace feature is not enabled": Enable the cell trace feature at BTS. Then try to activate again the required cell/interface trace session(s). The feature flag used for activating cell trace and interface trace is the same. - "trace reference in use, trace cannot be started": This problem is out of scope to be fixed at BTS and is scope of NMS(Network Management System) used to activate the cell/interface trace. The error means that there is already an active cell/interface trace at BTS using the same Trace Reference Number. Possible solution is to try deactivating all cell and interfaces traces. Then try activating them again. - "max number of cell/interface trace sessions reached, trace cannot be started": This problem is out of scope to be fixed at BTS and is scope of NMS(Network Management System) used for cell/interface trace activation. This error indicates that already 12 active cell/interface trace sessions (which is the maximum number of active cell and interface trace sessions put together supported at BTS at any point in time) has already been reached at BTS. Try to stop an already active cell/interface trace session at NMS before activating any new cell/interface trace(s). Related faults
Related information
Fault view
Id:0900d80580954a25
©2014/6/4NokiaSolutionsandNetworks
Fan failure 1/1
Fan failure Fault ID and name Usedinproducts Detectingunit
3050: EFaultId_FanFailure LTE FSM,FR
Source
FSM/FAN, FR
Meaning
A fan, all the fan s or m ore than one fan in the same fan group are rotating slower than requested, are not rotating at all, or the RPM information is not available for the fans. The reason for this fault can be a broken fan.
State
Start Cancel /
Unit status
N/A
Unit status attributes
Effect
Reported alarms
LED display
If the fans are not rotating as expected, there is a risk that the module temperature rises too high. For example, a Temperature fault might be generated from the alarming module. 7652 BASE STATION NOTIFICATION 7655 CELL NOTIFICATION N/A Note: Perform the steps below in the listed order until the BTS fault disappears.
Instructions
1. Check the fan and cabling. 2. Replace the faulty fan module. Fan module operation degraded 0: EFaultId_ChangeFanAl Fan module faulty 1: EFaultId_FanPowerAl
Related faults
No module fan detected 1932: EFaultId_FrNoFansDetected Cooling fan broken 1933: EFaultId_FrFanBroken Cooling fan has reduced from the set speed 1934: EFaultId_FrFanReducedSetSpeed Cooling fan is over speeding 1935: EFaultId_FrFanOverSpeed
Related information
Fault view
Id:0900d805809549ee
©2014/6/4NokiaSolutionsandNetworks
Fan module faulty: 1/1
Fan m odule faulty: FaultID and name Usedinproducts Detectingunit
1:EFaultId_FanPowerAl LTE FCM
Source
FAN
Meaning
All the fans or more than one fan in the same fan group are rotating more slowly than requested.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
alarming fans = out of order, fan group = out of order
Effect
If the fans are not rotating as requested, there is a risk that the module temperature rises too high.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablered 1. Check the fans and connector.
Instructions 2. Replace the fan module. Related faults
Fan failure 3050: EFaultId_FanFailure
Related information
Fault view
Id:0900d80580954a47
©2014/6/4NokiaSolutionsandNetworks
Fan module operation degraded: 1/1
Fan module operation degraded: FaultID and name Usedinproducts Detectingunit
0: EFaultId_ChangeFanAl LTE FCM
Source
FAN
Meaning
A fan is not rotating or is rotating more slowly than at the requested speed, or the RPM information is not available for the fan.
State
Start Cancel /
Unitstatus
Outoforder;Degraded
Unit status attributes
alarming fan = out of order, fan group = degraded
Effect
If the redundant fans cannot cool the module sufficiently, unit overheating might occur. For example, a temperature fault from the FCM might be generated.
Reported alarms
7652BASESTATIONNOTIFICATION
LED display
NORA: Blinking Red, Flexi: Stable Yellow(Fan Group Degraded) 1. Check the fan and connector.
Instructions 2. Replace the fan module. Related faults
Fan failure 3050: EFaultId_FanFailure
Related information
Fault view
Id:0900d80580954a46
©2014/6/4NokiaSolutionsandNetworks
Fan vendor not detected 1/1
Fan vendor not detected Fault ID and name
4073: E FaultId_FanVendorNotDetectedAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCT
Source
FAN1-n
Meaning
Fan speed is too low for successful detection. Detection attempt takes place again after the fan test timer expires.
State
Start Cancel /
Unit status
Working
Unit status attributes Effect
Fan control is not optimized. Effect to noise/temperature level is marginal.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Instructions Related faults
Stablegreen 1. Check the fan and connector. 2. Replace the fan. Fan failure 3050: EFaultId_FanFailure
Related information
Fault view
Id:0900d80580954a2a
©2014/6/4NokiaSolutionsandNetworks
Fatal OSE Error 1/1
Fatal OSE Error Fault ID and name
418: EFaultId_OseFatalErr
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSP
Source
FSP
Meaning
The operating system (OSE) goes into the error handler with a fatal status. The cause can be, for example, an out of memory situation. If only one FSP in BTS generates this fault, there is malfunction in one of the FSP submodules. If all FSPs generate this fault, there is malfunction in the FSM.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
LED display
The BTS capacity decreases or BTS is not operational. The Digital Signal Processing (DSP) does not work correctly. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED Stable red (7650), Blinking red (7651) Note! Perform the steps below in the listed order until the fault disappears.
Instructions
1. Reset the System Module. 2. Replace the System Module.
Related faults
System Module failure 3000: EFaultId_SystemModuleFailure
Related information
Fault view
Id:0900d805809548b4
©2014/6/4NokiaSolutionsandNetworks
Fault diagnostics rule file error 1/1
Fault diagnostics rule file error Fault ID and name
Usedinproducts
1866: EFaultId_RulesMissingAl 1867: EFaultId_RulesParsingAl FlexiBTS,LTE
Detectingunit
FCM[FSMr2]/FCT[FSMr3]
Source
FCM[FSMr2]/FCT[FSMr3]
Meaning
The Fault diagnostics rule file is missing or its parsing has failed.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
TheBTSdoesnotoperate.
Reportedalarms
7650BASESTATIONFAULTY
LEDdisplay
Stablered(7650) Note: Perform the following steps in the listed order until the fault disappears: 1. Download two different software packages so that the faulty file is removed from the BTS.
Instructions 2. Download the software again. 3. Replace the System Module. Related faults
BTS internal SW management problem 3090: EFaultId_BtsInternalSwManagementProblem
Related information
Fault view
Id:0900d8058099e6ce
©2014/6/4NokiaSolutionsandNetworks
File corrupted in SW download 1/1
File corrupted in SW download FaultID and name
28:EFaultId_SwPackageAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FlexiBTS:FCM(FSMr2)/FCT(FSMr3),FR
Meaning
The downloaded SW is corrupted or incorrectly formed.
State
Start Cancel /
Unit status
Working
Unit status attributes Effect
Reported alarms
LEDdisplay
TheBTScontinuesitsoperationwiththeold software. 7652 BASE STATION NOTIFICATION 7655 CELL NOTIFICATION Stablegreen
Instructions
1. Retry the SW update. 2. Save the snapshot and check the download status from the BTS SWDLreport in the snapshot file.
Related faults
BTS internal SW management problem 3090: EFaultId_BtsInternalSwManagementProblem
Related information
Fault view
Id:0900d80580954a4a
©2014/6/4NokiaSolutionsandNetworks
File System access failed 1/1
File System access failed Fault IDa nd name Usedinproducts Detectingunit
4088:E FaultId_FileSystemAccessFailedAl LTE FCM,FCT
Source
FCM, FCT
Meaning
File System access operations like File System mounting or file opening failed.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
Module cannot: 1. Save in file a cause of the SW fallback on request. or 2. Mount passive File System thus read the cause of SW fallback on request from the file.
Reportedalarms
7650BASESTATIONFAULTY
LEDdisplay
Stablered(7650)
Instructions
Update SW to the BTS, unless it is automatically updated by NetAct.
Related faults
Related information
Fault view
Id:0900d80580954a2e
©2014/6/4NokiaSolutionsandNetworks
Filter unit operation failed 1/1
Filter unit operation failed 1840: EFaultId_TuningFailureAl Fault ID and name
1841: EFaultId_UnitFaultyAl 4043: EFaultId_TuningFrequencyOutOfRangeAl
Usedinproducts
LTE
Detectingunit
Flexi Filter, External Filter,RFM
Source
TX1-n RX1-n /
Meaning
A filter has not been able to tune on an appropriate sub-band properly (tuning failure), or another major failure has been detected by the filter (unit faulty).
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
The signal path is unusable. The cells using the faulty unit might not work. 7652 BASE STATION NOTIFICATION
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LEDdisplay
Stablered In case of 4043:EFaultId_TuningFrequencyOutOfRangeAl: reconfigure the frequency settings.
Instructions In case of 1840:EFaultId_TuningFailureAl, 1841:EFaultId_UnitFaultyAl: replace the filter unit. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d805809549c8
©2014/6/4NokiaSolutionsandNetworks
Firmware SW mismatch 1/1
Firmware SW mismatch Fault ID and name
2056:EFaultId_SwMismatchAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCT,FSP
Source
FCT, FSP
Meaning
The SW update to the BTS has failed or BTS SW corrupted.
State
Start
Unitstatus
Outoforder;Working
Unit status attributes
Working - if raised for SSD firmware update. Out of order - in any other case.
Effect
SWupdateneeded.
Reported alarms
LED display
7650 BASE STATION FAULTY 7652 BASE STATION NOTIFICATION Stable red (7650), Stable green (7652) 1. Switch to recently active BTS configuration.
Instructions 2. Retry the SW update. Related faults
Related information
Fault view
Id:0900d80580a34382
©2014/6/4NokiaSolutionsandNetworks
Flash operation failure 1/1
Flash operation failure 214: EFaultId_FlashWrAl 215: EFaultId_FlashRdAl Fault ID and name
216: EFaultId_FlashEraseAl 217: EFaultId_FlashDrvAl 218: EFaultId_FlashDbChksumAl
Usedinproducts Detectingunit
FlexiBTS,LTE FlexiBTS:FCM/FCT
Source
FlexiBTS:FCM/FCT
Meaning
A flash m emory operation failure. If this alarm continuously appears, the flash chip might be broken.
State
Start
Unit status
Degraded
Unit status attributes
Effect
The BTS memory operations, for example the software download and parameter updates, are not stable. ISTI (In Service Time Indicator) value for HW Repair Center might not be correct or readable.
Reported alarms LEDdisplay
7651BASESTATIONOPERATIONDEGRADED Blinkingred FlexiBTS: 1. Check the other active alarms. If the ROM disk is corrupted, change the alarming module.
Instructions
Related faults
2. Block/unblock the alarming module. There are no recovery actions and because of that the block/unblock can be tried once. If that does not help, replace the alarming module.
BTS internal SW management problem 3090: EFaultId_BtsInternalSwManagementProblem
Related information
Fault view
Id:0900d805809548b2
©2014/6/4NokiaSolutionsandNetworks
Frame clock deviation fault 1/1
Frame clock deviation fault Fault ID and name Usedinproducts Detectingunit
2014: EFaultId_Muksu_SFCRCompDevAl LTE FCM,FCT
Source
FCM, FCT
Meaning
Synchronization to the clock control unit frame pulse has been achieved earlier, but it differs from the currently received frame pulse. The internally generated frame clock might have drifted.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
The traffic between the System Module and RF Module is unreliable. Some calls or other connections might be lost.
Reportedalarms
7650BASESTATIONFAULTY
LEDdisplay
Stablered 1. Check the cables between the System Module and RF Module.
Instructions
2. Reset the alarming System Module. 3. Replace the alarming System Module.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d805809549de
©2014/6/4NokiaSolutionsandNetworks
Frame clock missing 1/1
Frame clock missing Fault ID and name
1903:E FaultId_FrFrameClockMissing
Usedinproducts
FlexiBTS,LTE
Detectingunit
FRxLTX /
Source
LTX, RX1-n
Meaning
The System Module clock reference differs from the RF Module clock.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
LED display
Calls are not possible through the affected cell(s) (7653 CELL FAULTY). There can be problems in the calls through the affected cell(s) (7654 CELL OPERATION DEGRADED). 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Stable red (7653), Blinking red (7654) 1. Check the cables between the System Module and RF Module. 2. Block/unblock the RF Module.
Instructions 3. If that does not help, block/unblock the site. 4. If that does not help, replace the alarming RF Module. Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d8058095b9dd
©2014/6/4NokiaSolutionsandNetworks
Frame number synchronization error in optical interface 1/1
Frame number synchronization error in optical interface Fault ID and name Usedinproducts Detectingunit
2047: EFaultId_OIC_FrSyncLostAl LTE FCM,FCT
Source
FSM, OptIF
Meaning
The timing of the new RP1 synchronization burst deviates from the present RP1 timing maintained in the System Module.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
LEDdisplay
The System Module is faulty if this fault is active after a reset. The cell is faulty if this fault is interface-specific. 7650 BASE STATION FAULTY 7653 CELL FAULTY Stablered 1. Reset the System Module that causes the alarm.
Instructions 2. If resetting the module does not help, replace the System Module that causes the alarm. Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d805809549e7
©2014/6/4NokiaSolutionsandNetworks
FSP in resetting state 1/1
FSP in r esetting state Fault ID and name
4068: EFaultId_FspResetAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FSP
Meaning
FSPisundergoingacoldreset.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LED display
The BTS functionality is degraded and/or resources are unavailable. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED Blinking red (7651), Stable red (7650) Note! Perform the steps below in the listed order until the fault disappears:
Instructions
Related faults
1. Reset the BTS. 2. Replace the faulty module/unit. System Module failure 3000: EFaultId_SystemModuleFailure
Related information
Fault view
Id:0900d80580954a22
©2014/6/4NokiaSolutionsandNetworks
FSP overheating 1/1
FSP overheating Fault ID and name
4077: EFaultId_FspOverheatingAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCT
Source
FSP
Meaning
Temperature on FSP board exceeds critical threshold value.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
LEDdisplay
FSP resource is shut down, the BTS operation will be degraded or faulty. FCT and possible other not alarming FSPs are kept powered. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED Stablered(FSP)
Instructions
1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the alarming module.
Related faults
Temperature alarm 3040: EFaultId_TemperatureAlarm
Related information
Fault view
Id:0900d80580954a31
©2014/6/4NokiaSolutionsandNetworks
GPS Receiver alarm: control interface not available 1/1
GPS Receiver alarm: control interface not available Fault ID and name Usedinproducts Detectingunit
4011:EFaultId_GPSSystemElementAl LTE FCM/FCT
Source
FCM/FCT
Meaning
BTS has detected communication problem with the GPS receiver. Fault is ignored until the GPS receiver has reached the commissioned state.
State
Start Cancel /
Unit status
Working
Unit status attributes Effect
The fault has no direct impact on the operation (BASE STATION NOTIFICATION).
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablegreen Perform the steps below in the listed order until the fault disappears. If after autonomous GPS power reset, fault does not get cancelled (wait 5min from fault start prior to starting actions in below).
Instructions
Control Interface not available: 1. The BTS has detected a malfunction in the control interface of the GPS receiver. Possible reason could be that BTS and GPS receiver does not support common interface. Otherwise, perform a (remote) power reset for the GPS receiver. 2. Perform a (remote) BTS site reset for the whole BTS. 3. Perform a power reset for the whole BTS. 4. The cable between the GPS receiver and the BTS might work improperly. Check the pins of the connectors (both ends of the cable) are free from oxide and other kind of dirt, meaning that the pin connection quality is good. 5. The cable between the GPS receiver and the BTS might be faulty. Check the situation and change the cable, if needed. 6. There might be a HW fault in the GPS receiver. Check the operation and change the GPS module, if needed. 7. There might be a HW fault in the BTS System Module. Check the operation and change the System Module, if needed.
Related faults
Related information
Fault view
Id:0900d80580a56fad
©2014/6/4NokiaSolutionsandNetworks
GPS receiver alarm: EEPROM invalid 1/1
GPS receiver alarm: EEPROM invalid Fault ID and name Usedinproducts Detectingunit
4126: EFaultId_GpsReceiverEepromInvalidAl LTE FCM/FCT
Source
GNSS
Meaning
GPS receiver has detected that one or more EEPROM segments have been found to be corrupted at reset and had to be set to their factory default settings.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
The fault has no direct impact on the operation (BASE STATION NOTIFICATION).
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablegreen Perform the steps below in the listed order until the fault disappears.
Instructions
EEPROM invalid: 1. The GPS receiver has detected a malfunction in the EEPROM memory of the GPS receiver. Perform a (remote) power reset for the GPS receiver. 2. There might be a HW fault in the GPS receiver. Check the operation and change the GPS module, if needed.
Related faults
Related information
Fault view
Id:0900d80580954a44
©2014/6/4NokiaSolutionsandNetworks
GPS receiver alarm: no stored position 1/1
GPS receiver alarm: no stored position Fault ID and name Usedinproducts Detectingunit
4124: E FaultId_GpsReceiverNoStoredPositionAl LTE FCM/FCT
Source
GNSS
Meaning
Thereisno accurateposition stored in EEPROM.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
The fault has no direct impact on the operation (BASE STATION NOTIFICATION).
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablegreen Perform the steps below in the listed order until the fault disappears.
Instructions
No stored position: 1. One of the GPS receiver settings is incorrect. Using the manager SW of the GPS receiver, set the receiver to store the position into non-volatile memory. If there is no tick mark in the position storage selection, the GPS receiver runs the site/self survey every time the GPS receiver is reset (either by manager command, by power outage or by a GPS recovery reset). This means that if the GPS receiver installation quality is only an average - and especially if the installation is a poor one - the GPS receiver turns the PPS reference OFF every now and then during the site survey. This means the BTS master clock drops to holdover mode much easier during the survey than during the normal operation.
Related faults
Related information
Fault view
Id:0900d80580954a41
©2014/6/4NokiaSolutionsandNetworks
GPS receiver alarm: not tracking satellites 1/1
GPS receiver alarm: not tracking satellites Fault ID and name Usedinproducts Detectingunit
4122: E FaultId_GpsReceiverNotTrackingSatellitesAl LTE FCM/FCT
Source
GNSS
Meaning
PoorGPSantennainstallation
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
The fault has no direct impact on the operation (BASE STATION NOTIFICATION).
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablegreen Perform the steps below in the listed order until the fault disappears.
Instructions
Not tracking satellites: 1. Absolutely the most common reason for this fault indication is that the GPS antenna installation has not been done properly, that is the sky visibility is not good enough. Refer to the documentation for installations and if there are deviations with the actual installation, re-install the GPS antenna. Note that even when the GPS antenna has a good sky visibility, the problem might be caused by installing the GPS antenna too close to the transmitter antenna(s) of the BTS, causing disturbances for the GPS receiver. 2. There might be a malfunction in the GPS receiver. Perform a (remote) power reset for the GPS receiver. 3. There might be a HW fault in the GPS receiver. Check the operation and change the GPS module, if needed.
Related faults
Related information
Fault view
Id:0900d80580954a40
©2014/6/4NokiaSolutionsandNetworks
GPS receiver alarm: position questionable 1/1
GPS receiver alarm: position questionable Fault ID and name Usedinproducts Detectingunit
4125: E FaultId_GpsReceiverPositionQuestionableAl LTE FCM/FCT
Source
GNSS
Meaning
The receiver is used in stored position but has been moved to a new position after that.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
The fault has no direct impact on the operation (BASE STATION NOTIFICATION).
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablegreen Perform the steps below in the listed order until the fault disappears.
Instructions
Position questionable: 1. The GPS receiver has valid position data but it is not properly in line with the information estimated from the actual satellite visibility. The reason for this fault indication might be that the GPS antenna installation has not been done properly, that is the sky visibility is not good enough. Refer to the documentation for instructions and if there are deviations with the actual installation, re-install the GPS antenna. Note that even when the GPS antenna has a good sky visibility, the problem might be caused by installing the GPS antenna too close to the transmitter antenna(s) of the BTS, causing disturbances for the GPS receiver. 2. There might be a malfunction in the GPS receiver. Perform a (remote) power reset for the GPS receiver. 3. There might be a HW fault in the GPS receiver. Check the operation and change the GPS module, if needed.
Related faults
Related information
Fault view
Id:0900d80580a38d89
©2014/6/4NokiaSolutionsandNetworks
GPS receiver alarm: survey in progress 1/1
GPS receiver alarm: survey in progress Fault ID and name Usedinproducts Detectingunit
4123: E FaultId_GpsReceiverSurveyInProgressAl LTE FCM/FCT
Source
GNSS
Meaning
TheGPS receiverisrunning asite/self survey
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
The fault has no direct impact on the operation (BASE STATION NOTIFICATION).
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablegreen Perform the steps below in the listed order until the fault disappears.
Instructions
Survey in progress: 1. Do nothing. The alarm is informative only. Normally, the GPS receiver runs the survey for two reasons: a) somebody has started the survey manually, b) the GPS receiver has noticed that the position has changed and the receiver has started an automatic survey. Note also that automatic survey takes place every time during first start-up. 2. If the automatic survey takes place every now and then, it might be an indication that the sky visibility is poor and according to the poorly tracked satellites, the GPS receiver concludes that the position has changed. In this case, check the activity of the other faults (BTS fault history data) and if found feasible, make re-installation of the GPS antenna. 3. If the GPS installation is good but still the automatic survey takes place every now and then, there might be a malfunction in the GPS receiver. Perform a (remote) power reset for the GPS receiver. 4. If the actions detailed in previous steps do not correct the situation, there might be a HW fault in the GPS receiver. Check the operation and change the GPS module, if needed.
Related faults
Related information
Fault view
Id:0900d80580954a42
©2014/6/4NokiaSolutionsandNetworks
GTP-U Path Failure 1/1
GTP-U Path Failure Fault ID and name Usedinproducts Detectingunit
6150: E FaultId_GtpuPathFailure LTE FCM,FCT
Source
GTP-U
Meaning
In GTP-U supervision, a network element did not respond to the GTP-U: Echo Request message within time.
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Effect
For S1: The eNB lost the connection to S-GW. All calls using the failed GTP-U data path are released, and new GTP-U data tunnels are not created for the failed GTP-U data path until it works again.
Reported alarms
7657BASESTATIONCONNECTIVITYDEGRADED
LED display
Instructions
N/A 1) Check the GTP-U path supervision configuration of the eNB. 2) Check the supervised network element for proper operation. 3) Check the communication equipment in between the eNB and the supervised network element.
Related faults
Related information
Fault view
Id:0900d80580954a05
©2014/6/4NokiaSolutionsandNetworks
Heating element not working 1/1
Heating element not working Fault ID and name Usedinproducts Detectingunit
1860: EFaultId_HeatingMatNotWorkingAl LTE FCM
Source
FCM
Meaning
The heater control connection of the FSM is faulty, there is no heater or the heater is faulty.
State
Start Cancel /
Unit status
Working
Unit status attributes
Effect
Heating from the heating element is not available. The module temperature may not reach the working level or may reach it very slowly.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablegreen 1. Check whether the heating element exists at all.
Instructions
2. Check the heater control connection and that the heater is working. 3. Replace the alarming component.
Related faults
Related information
Fault view
Id:0900d805809549e3
©2014/6/4NokiaSolutionsandNetworks
Incoherency in cell configuration 1/1
Incoherency in cell configuration Fault ID and name Usedinproducts Detectingunit
1856: EFaultId_IncoherencyInCellConfigurationAl LTE FCM
Source
FR
Meaning
More than one sector configuration types (A, G, H) are configured to the same RF Module.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Thecapacitydrops.Cell(s)mightremaindown.
Reportedalarms
7653CELLFAULTY
LEDdisplay
Stablegreen
Instructions
Recommission the LCRs in a way that only one sector type is used in one RF Module.
Related faults
Configuration error: 3070: EFaultId_ConfigurationError
Related information
Fault view
Id:0900d805809549d7
©2014/6/4NokiaSolutionsandNetworks
Incoherency in cell configuration 1/1
Incoherency in cell configuration Fault ID and name Usedinproducts Detectingunit
4000: EFaultId_IncoherencyInConfiguration LTE FCM
Source
FSM, LCR
Meaning
ToomanyLCRsarecommissionedtooneRFModule.
State
Start Cancel /
Unitstatus
Outoforder;Working
Unit status attributes
Working (FSM) Out of Order (LCR)
Effect
Reported alarms
LEDdisplay
TheBTScapacitymayhavedecreased. 7652 BASE STATION NOTIFICATION 7653 CELL FAULTY Stablegreen
Instructions
Recommission the BTS with a correct number of LCRs per RF Module.
Related faults
Configuration error: 3070: EFaultId_ConfigurationError
Related information
Fault view
Id:0900d805809549ff
©2014/6/4NokiaSolutionsandNetworks
Incoherency In Cell Configuration 1/1
Incoherency In Cell Configuration Fault ID and name Usedinproducts Detectingunit
4044: EF aultId_IncoherencyCellConfigurationAl LTE FSM
Source
LCR
Meaning
Cell configuration is not officially supported.
State
Start
Unit status
Working
Unit status attributes Effect
This cell-specific fault does not prevent cell configuration. It is for informative purposes only.
Reportedalarms
7655CELLNOTIFICATION
LEDdisplay
Stablegreen
Instructions
Check the configuration of the configured cell.
Related faults
Configuration error: 3070: EFaultId_ConfigurationError
Related information
Fault view
Id:0900d80580954a19
©2014/6/4NokiaSolutionsandNetworks
Incoherency with RF Modules 1/1
Incoherency with RF Modules Fault ID and name Usedinproducts Detectingunit
1857: EFaultId_IncoherencyWithRFModulesAl LTE FCM
Source
FR
Meaning
Incorrect cell configuration for RF modules with a different frequency. The same cell is configured for two RF modules which are not at the same frequency.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Thecapacitydrops.Cell(s)mightremaindown.
Reportedalarms
7653CELLFAULTY
LEDdisplay
Stablegreen 1. Check which Radio Modules are at for an incorrect frequency.
Instructions 2. Replace the incompatible Radio Module(s). Related faults
Configuration error: 3070: EFaultId_ConfigurationError
Related information
Fault view
Id:0900d805809549d8
©2014/6/4NokiaSolutionsandNetworks
Incompatible SW version detected 1/1
Incompatible SW version Fault ID and name
Usedinproducts
Detectingunit
detecte d 23: EFaultId_IncompatibleSwVersionAl 24: EFaultId_ObsoleteSwVersionAl LTE
FCM
Source
FCM,FR,FF,FA,FSP,FTM
Meaning
A new module with incompatible SW has probably been inserted in the BTS.
State
Start Cancel /
Unitstatus
Outoforder;Working
Unit status attributes
Working (FCM detected unsupported fsType value in TargetBD downloaded in SW update) Out of Order (Otherwise)
Effect
Resources provided by the module cannot be used, which means that some features might not work. If the fault is reported for FR module, BTSOM does not know the real FR module state, and thus BTS SM keeps FR LED display disabled (grayed). The reason for FR LED status inconsistency is the restriction of RP1 communication only to SW management procedures in case of SW mismatch situation. Hence, there is no possibility to align RF LED and BTS SM LED display status. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
Reported alarms
7652 BASE STATION NOTIFICATION 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Stable red (7650, 7653), blinking red (7651, 7654)
Instructions
Update compatible SW to the BTS (check the SW versions to see the active SW version, and update the active SW version), unless it is automatically updated by NetAct.
Related faults
Related information
Fault view
Id:0900d80580954a4b
©2014/6/4NokiaSolutionsandNetworks
Incorrect radio network parameters 1/1
Incorrect radio network parameters FaultIDa ndn ame
6252:E FaultId_FailureInNetworkPlanFile
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FSM
Meaning
There was an opening, reading, or file content problem with a radio network configuration file at the BTS startup or at activation of delta configuration file. The detected problem can be a file handling problem (for example open, read, and write operations fail) as well as a contents problems (for example no valid RAML2.1 format).
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
BTS is not configured according to radio network plan file. BTS is waiting for the correct radio network configuration file.
Reportedalarms
7650BASESTATIONFAULTY
LEDdisplay
Stablered Note: Perform the steps below in the listed order until the BTS fault disappears.
Instructions
1. Check the commissioning parameters with the BTS Site Manager Commissioning Wizard. 2. Load the correct commissioning file to the BTS.
Related faults
Commissioning error: 3060: EFaultId_CommissioningError
Related information
Fault view
Id:0900d80580954a0d
©2014/6/4NokiaSolutionsandNetworks
Increased BER detected on the optical connection to Radio Module 1/2
Increa sed BER de tected on the opti cal connection to Radio Module Fault ID and name Usedinproducts Detectingunit
1955:E FaultId_IncrBerOnRp3 LTE FRxLTX /
Source
FR
Meaning
Increased bit error rate has been detected on the optical link to radio module which results in sporadical LCV errors in downlink baseband processing.
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Effect
Reported alarms
LEDdisplay
Calls and data transmissions are possible with degraded quality and lower bandwidth because of increased bit error rate on optical connection. 7652 BASE STATION NOTIFICATION 7654 CELL OPERATION DEGRADED Blinkingred Instructions are divided into three sections. Execute steps from section chosen based on best knowledge and common sense to minimize the cost and time effort. Section A: Check on system module side: 1. Check if connector seal is properly mounted and firmly in place. 2. Check if the SFP (Small Form Factor Pluggable) is properly connected/mounted in the System Module. If SFP connection/mounting is not correct readjust the connection/mounting. 3. Check if the LED indicates the faulty SFP (connected to System Module). Replace the SFP if it is faulty. 4. Check if the optical cable is properly connected/mounted in the SFP. 5. Clean the optical connectors that are connected to SFP. Reset RF HW unit by block/unblock procedures and check if this solves the problem.
Instructions
Section B: Check on radio module side: 1. Check if connector seal is properly mounted and firmly in place. 2. Check if the SFP (Small Form Factor Pluggable) is properly connected/mounted in the RF module. If SFP connection/mounting is not correct readjust the connection/mounting. 3. Check if the optical cable is properly connected/mounted in the SFP. 4. Clean the optical connectors at RF module end. Reset RF HW unit by block/unblock procedures and check if this solves the problem. Section C: Check of optical connection: 1. Check if optical cables are not over bend. If yes then replace the optical cable since over bending the optical fiber cables damages the cables and can detach or damage the connectors. 2. OPTIONAL: Test the fiber cable (f.ex. measure the optical attenuation) from System Module end. Please check measuring equipment documentation for instruction details. 3. OPTIONAL: Test the fiber cable (f.ex. measure the optical attenuation) from RF Module end. Please check measuring equipment documentation for instruction details. If alarm is still observed after executing steps from sections: A,B,C replace the RF module.
Increased BER detected on the optical connection to Radio Module 2/2
Related faults
Related information
Fault view
Id:0900d80580a5f1b4
©2014/6/4NokiaSolutionsandNetworks
Internal MTU configuration failure 1/1
Internal MTU configuration failure Fault ID and name Usedinproducts Detectingunit
4025: EFaultId_MtuConfigurationFailureAl LTE FCM
Source
FCM, FSP
Meaning
Internal Maximum Transfer Unit (MTU) configuration failed on FCM or FSP.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LED display
The BTS operation is degraded (FSP) or the BTS is not operational (FCM/all FSPs). 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED Stable red (7650), Blinking red (7651) 1. Reset the alarming System Module.
Instructions 2. Replace the alarming System Module Related faults
System Module failure 3000: EFaultId_SystemModuleFailure
Related information
Fault view
Id:0900d80580954a07
©2014/6/4NokiaSolutionsandNetworks
Invalid Configuration file 1/1
Invalid Configuration file Fault ID and name
4036: EFaultId_InvalidConfigurationFileAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCMFCT /
Source
FCM(FSMr2)/FCT(FSMr3)
Meaning
The commissioning file is missing, or an incorrect SCF file has been detected during BTS startup as follows: 1. Commissioning data: the commissioning file is missing or a parameter has a missing or incorrect value. 2. RNW data: "RNW not found", "RNW has wrong format", "RNW could not be parsed", "RNW has wrong schema", "Validation failed due to incompatible data" or "no RNW cell managedObject is created"
State
Start Cancel /
Unitstatus
Outoforder;Working
Unit status attributes
Out of order: when the problems prevents BTS to reach operational state (wrong or missing RNW data/active commissioning data not readable). Working: if there have been problems with commissioning data in SW package but still BTS is operational.
Effect
The BTS capacity might decrease or there might be interference in calls (commissioning data). BTS startup is interrupted and the BTS is out of order (RNW data).
Reported alarms
7650 BASE STATION FAULTY 7652 BASE STATION NOTIFICATION
LED display
Stable red (7650), Stable green (7652) 1. Check and correct the contents of the commissioning file.
Instructions 2. Recommission the BTS with the valid commissioning file. Related faults
Commissioning error: 3060: EFaultId_CommissioningError
Related information
Fault view
Id:0900d805809549f8
©2014/6/4NokiaSolutionsandNetworks
Invalid frequency channel for the BTS HW 1/1
Invalid frequency channel for Fault ID and name Usedinproducts Detectingunit
the BTS HW
1807: EFaultId_InvalidFrequencyChannelForBTSHW LTE FCM
Source
LCR
Meaning
The requested channel in the startup phase is not acceptable for the BTS hardware, because of an incorrect frequency band and/or a carrier spacing and/or the number of carriers.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
TheBTScapacitypossiblydecreases.
Reportedalarms
7653CELLFAULTY
LEDdisplay
Stablegreen
Instructions
Check the frequencies' parameters against the BTS HW configuration. The frequency is out of the min/max limit of the HW, or the number of carriers for the HW type is exceeded, or the carrier spacing limit is exceeded. There are different types of variations of the HW that might have limitations in the supported frequency range and bandwidth.
Related faults
Configuration error: 3070: EFaultId_ConfigurationError
Related information
Fault view
Id:0900d8058099e648
©2014/6/4NokiaSolutionsandNetworks
Low noise amplifier failure 1/1
Low noise amplifier failure Fault ID and name Usedinproducts Detectingunit
1839: EFaultId_LNAFailureAl LTE FlexiFilter
Source
RX1-n
Meaning
The Filter has detected a malfunction in the LNA unit.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
TheRXpath operating performancehasdecreased. 7652 BASE STATION NOTIFICATION
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Stable red (if all LNAs of the RF module are faulty); Blinking red (if not all LNAs of the RF module are faulty)
Instructions
ReplacethealarmingRadiomodule.
Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d805809549c7
©2014/6/4NokiaSolutionsandNetworks
Mast Head Amplifier fault 1/1
Mast Head Amplif ier fault Fault ID and name Usedinproducts Detectingunit
3120: EFaultId_MastHeadAmplifierFault LTE FSM,FR
Source
FF, AISG MHA
Meaning
The FlexiBTS has detected an abnormal operation or a failure in the Masthead Amplifier (MHA). Note that the Tower Mounted Amplifier (TMA) is a synonym for the MHA and is used by the Antenna Interface Standards Group (AISG).
State
Start Cancel /
Unit status
N/A
Unit status attributes
Effect
Reported alarms
LED display
Depending on the reported alarms, the fault situation might have no impact on the operation (BASE STATION NOTIFICATION), or the BTS capacity may have decreased (BASE STATION or CELL OPERATION DEGRADED). 7652 BASE STATION NOTIFICATION 7654 CELL OPERATION DEGRADED N/A Note: Perform the steps below in the listed order until the BTS fault disappears. 1. Check the cables related to the Masthead Amplifier (MHA).
Instructions
2. Reset the alarming MHA module by blocking/unblocking the RF Module which the MHA is connected to. 3. Replace the faulty device(s).
Related faults
Mast Head Amplifier fault, 1834: EFaultId_AboveCurrentWindowAl 1835: EFaultId_BelowCurrentWindowAl MHA unit operation failure 1869: EFaultId_MinorTMAFaultAl 1870: EFaultId_MajorTMAFaultAl
Related information
Fault view
Id:0900d805809549f3
©2014/6/4NokiaSolutionsandNetworks
Mast Head Amplifier fault above current window, 1/1
Mast Hea d Ampl ifier fault above current w Fault ID and name Usedinproducts Detectingunit
indow ,
1834: EFaultId_AboveCurrentWindowAl LTE FR,FF
Source
MHA
Meaning
The Masthead Amplifier (MHA) does not work properly. The received RF signal level is decreased. If both stages of the LNA on the uplink path fail, the MHA switches the LNA to by-pass mode. In by-pass mode, the MHA has no gain but some loss. If only one stage of the LNA fails, the MHA still has about half of its normal gain. With an integrated MHA (WMHC), the fault might affect both main and diversity branches or just one of them.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
If the MHA is faulty, the RX performance is degraded. The size of the cell might be reduced.
Reported alarms
7654CELLOPERATIONDEGRADED
LED display
Stable red (RF module faulty), Alternating red and green (RF module working, MHA faulty) 1. Check the antenna cables and connectors towards the MHA. Fix or replace the broken parts.
Instructions
2. Restart the MHA by blocking and unblocking the Flexi Radio (FR) Module. NOTE! This operation affects all antenna lines and cells related to the FR Module, not just the faulty one. If the alarm reappears, replace the alarming module.
Related faults
Mast Head Amplifier fault 3120: EFaultId_MastHeadAmplifierFault
Related information
Fault view
Id:0900d8058095b938
©2014/6/4NokiaSolutionsandNetworks
Mast Head Amplifier fault below current window, 1/1
Mast Hea d Ampli fier fault below c urrent wi ndow, Fault ID and name Usedinproducts Detectingunit
1835: EFaultId_BelowCurrentWindowAl LTE FR,FF
Source
MHA
Meaning
The Masthead Amplifier (MHA) does not work properly. The received RF signal level is decreased. If both stages of the LNA on the uplink path fail, the MHA switches the LNA to by-pass mode. In by-pass mode, the MHA has no gain but some loss. If only one stage of the LNA fails, the MHA still has about a half of its normal gain. With an integrated MHA (WMHC), the fault might affect both main and diversity branches or just one of them.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
If the MHA is faulty, the RX performance is degraded. The size of the cell might be reduced.
Reported alarms
7654CELLOPERATIONDEGRADED
LED display
Stable red (RF module faulty), Alternating red and green (RF module working, MHA faulty) 1. Check the antenna cables and connectors towards the MHA. Fix or replace the broken parts.
Instructions
Related faults
2. Restart the MHA by blocking and unblocking the Flexi Radio (FR) Module. NOTE! This operation affects all antenna lines and cells related to the FR Module, not just the faulty one. If the alarm reappears, replace the alarming module. Mast Head Amplifier fault 3120: EFaultId_MastHeadAmplifierFault
Related information
Fault view
Id:0900d8058095b9e4
©2014/6/4NokiaSolutionsandNetworks
Master unit has lost connection to the slave unit 1/1
Master unit has lost connection to the slave unit Fault ID and name
4019: E FaultId_KeepAliveStatusErrorAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FCM[FSMr2],FCT[FSMr3],FSP,DSP
Meaning
Connection to the DSP submodule has been lost or the submodule reports an error situation.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LED display
TheBTSresources havedecreased orthe BTSis faulty. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED Stable red (7650) , Blinking red (7651) Note! Perform the steps below in the listed order until the fault disappears.
Instructions
Related faults
1. Reset the BTS. 2. Replace the faulty module. System Module failure 3000: EFaultId_SystemModuleFailure Failure in replaceable baseband unit 3003: EFaultId_FbiaFailureAl
Related information
Fault view
Id:0900d80580a3421e
©2014/6/4NokiaSolutionsandNetworks
Maximum number of neighbor eNBs/cells exceeded 1/1
Maximum number of neighbor eNBs/cells exceeded Fault ID and name Usedinproducts Detectingunit
6265:EFaultId_MaximumNumberOfNeighbourEnbsOrCellsExceeded LTE FCM/FCT
Source
FCM
Meaning
This alarm indicates that the maximum number of LNADJ and/or LNADJL was exceeded in eNB and that the new object was not stored.
State
Transient
Unit status
Working
Unit status attributes
Effect
The fault has no effect on the base station operation but LNADJ and/or LNADJL object was not stored in eNB.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
StableGreen 1.Check if maximum number of LNADJ was reached. If yes, check if there are LNADJ objects that can be manually deleted. This makes space for new LNADJ information.
Instructions
2.Check if maximum number of LNADJL was reached. If yes, check if there are LNADJL objects related with LNADJ object that can be manually deleted. This makes space for new LNADJ information.
Related faults
Related information
Fault view
Id:0900d80580954a2c
©2014/6/4NokiaSolutionsandNetworks
MHA unit operation failure 1/1
MHA unit operation failure Fault ID and name
Usedinproducts
Detectingunit
1869: EFaultId_MinorTMAFaultAl 1870: EFaultId_MajorTMAFaultAl LTE
AISGMHA
Source
AISG MHA
Meaning
A fault in the Masthead Am plifier (MHA) is detected. The fault reduces the gain perform ance or completely prevents the MHA from functioning.
State
Start Cancel /
Unitstatus
Outoforder;Degraded
Unit status attributes
Degraded (MinorTMAFault) O ut of o rder (MajorTMAFault)
Effect
The MHA gain is decreased or even producing a loss. The cell performance is decreased.
Reported alarms
7652 BASE STATION NOTIFICATION 7654 CELL OPERATION DEGRADED
LED display
Alternating red and green (RF working, MHA faulty)
Instructions
Replacethealarmingmodule.
Related faults
Mast Head Amplifier fault 3120: EFaultId_MastHeadAmplifierFault
Related information
Fault view
Id:0900d805809549e4
©2014/6/4NokiaSolutionsandNetworks
Missing RNW parameter 1/1
Missing RNW parameter Fault ID and name
4009: EFaultId_RnwParameterMissingAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
LCR
Meaning
Mandatory parameter missing in the radio network configuration data.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Therelatedcellremainsdown.
Reportedalarms
7653CELLFAULTY
LEDdisplay
Stablered 1. Check that all mandatory parameters exist in the radio network data for the specific cell.
Instructions 2. Download and activate the corrected commissioning file to the BTS. Related faults
Configuration error: 3070: EFaultId_ConfigurationError
Related information
Fault view
Id:0900d805809549fe
©2014/6/4NokiaSolutionsandNetworks
Missing RP3-01 link 1/1
Missing RP3-01 link Fault ID and name Usedinproducts Detectingunit
4064: EFaultId_MissingRp301LinkAl LTE FCM
Source
RX, TX
Meaning
Not enough RP3-01 links connected between FSM and FR. Commissioned cells cannot be routed via existing RP3-01 links.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
LEDdisplay
Instructions
Not enough RP3-01 capacity for commissioned cells. Commissioned cells using the missing RP3-01 link are not activated. 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Blinkingred 4064 triggered during BTS startup: Note! Perform the steps below in the listed order until the fault disappears. 1. Check if other BTS fault indications are active. 2. Make sure that all RP3-01 fiber links and SFP transceivers between system module and radio module are properly connected and working. Add missing parallel RP3-01 links. 3. Restart the Radio Module. 4. Restart the BTS. 4064 triggered during BTS runtime: Change the faulty optical cable.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d80580954a21
©2014/6/4NokiaSolutionsandNetworks
Module dangerously overheating 1/1
Module dangerously overheating Fault ID and name Usedinproducts Detectingunit
4071: EF aultId_SysDangerouslyOverheatAl LTE FCM
Source
FSP
Meaning
The highest validated temperature value on the FSP board exceeds the threshold value.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
BB resources are shut down, the BTS operation will be faulty. FCM and FTM are kept powered.
Reportedalarms
7650BASESTATIONFAULTY
LEDdisplay
Stablered Note! Perform the steps below in the listed order until the fault disappears.
Instructions
Related faults
1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the alarming module. Temperature alarm 3040: EFaultId_TemperatureAlarm
Related information
Fault view
Id:0900d80580954a27
©2014/6/4NokiaSolutionsandNetworks
No connection to Flexi transport submodule 1/1
No connection to Flexi transport submodule Fault ID and name
3511: E FaultId_NoConnectionToFtAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
FTM
Meaning
The connection to the Flexi Transport submodule (FTM) is lost.
State
Start Cancel /
Unit status
N/A
Unit status attributes Effect Reportedalarms LED display
TheBTSisnotoperational. 7650BASESTATIONFAULTY N/A Note: Perform the steps below in the listed order until the BTS fault disappears.
Instructions
FlexiBTS: 1. Reset the site. 2. Replace the Transport submodule, which is located inside the System Module.
Related faults
No connection to unit 10: EFaultId_NoConnectionToUnitAl Communication failure 1806: EFaultId_CommunicationFailureAl
Related information
Fault view
Id:0900d80580954a00
©2014/6/4NokiaSolutionsandNetworks
No connection to unit 1/1
No connection to unit Fault ID and name
10: EFaultId_NoConnectionToUnitAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FSP,FT,FF,MHA,TILT,FR,FA,extensionFSM,
Meaning
Connection to a module that belongs to the BTS configuration has been lost.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
The module in question is out of use. This fault cancels all the active faults for the same module. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
Reported alarms
7652 BASE STATION NOTIFICATION 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Instructions
Stable red (7650; 7653), blinking red (7651; 7654), alt. red and green (7653 and 7654 [MHA, TILT]), stable green (7652) 1. Make sure that the module is properly connected. If the module LED does not light up, the module is faulty. Check the alarming module. 2. Check the fault history.
System Module failure 3000: EFaultId_SystemModuleFailure Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related faults
Antenna Line Device failure 3100: EFaultId_AntennaLineFailure No connection to Flexi transport submodule 3511: EFaultId_NoConnectionToFtAl WSP failure 3002: EFaultId_EubbWspAl Failure in replaceable baseband unit 3003: EFaultId_FbiaFailureAl
Related information
Fault view
Id:0900d8058099e6d0
©2014/6/4NokiaSolutionsandNetworks
No MME capacity assigned by Core Network 1/1
No MME capacity assigned by Core Network Fault ID and name Usedinproducts Detectingunit
6264: EFaultId_S1ZeroCapPlmns LTE FCM
Source
FCM
Meaning
BTS has encountered few possibly misconfigured PLMNs that cannot be used by BTS for accepting calls from new UEs selecting those PLMNs. These PLMNs that are considered misconfigured by BTS are: - currently configured at BTS for one or more cells - served by one or more MMEs and therefore currently broadcast by BTS's cells but none of these PLMNs have serving MME(s) with relative capacity greater than zero. Because of this, BTS cannot select any of these MMEs for any new UEs attempting registration in these PLMNs. All previously registered UEs in these PLMNs remain unaffected.
State
Start Cancel /
Unit status
Working
Unit status attributes
Effect
BTS cannot accept new UEs attempting registration in any of the reported misconfigured PLMNs. Such an attempt by new UEs results in call failure at BTS. The existing UEs that might
Reported alarms
7652BASESTATIONNOTIFICATION
have already registered in misconfigured PLMN(s) remain unimpacted.
LED display
Instructions
N/A Check and ensure that the PLMNs that have been listed with this BTS fault and that have been configured at BTS for one or more cells have at least one MME serving them and relative capacity of that MME is greater than zero.
Related faults
Related information
Fault view
Id:0900d80580954a26
©2014/6/4NokiaSolutionsandNetworks
No module fan detected 1/1
No module f an detecte d Fault ID and name Usedinproducts Detectingunit
1932: EFaultId_FrNoFansDetected LTE FR/RFSW
Source
RFSW
Meaning
Radio Module cannot identify the used fan type or the fan is not installed at all.
State
Start
Unit status
Working
Unit status attributes Effect
Defaultvaluesforfan parametersaretobeused.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stableorblinkingred(Fan) 1. Check that the fan connector is properly mounted.
Instructions 2. If that does not help, replace the fan module. Related faults
Fan failure 3050: EFaultId_FanFailure
Related information
Fault view
Id:0900d80580954a10
©2014/6/4NokiaSolutionsandNetworks
Not able to synchronize baseband bus with 1/1
Not able to synchron ize ba seband bus wit h Fault ID and name
1815: EFaultId_BbBus_SyncFailedAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT,FSP
Source
FSP,FCM/FCT,OptIF
Meaning
The baseband bus synchronization towards failed.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
This fault can prevent the BTS from functioning when the RF Module is needed for the required cell configuration. 7650 BASE STATION FAULTY
Reported alarms
7651 BASE STATION OPERATION DEGRADED 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display Instructions
Related faults
Stable red(7650): Blinking red (7651) Change the faulty module.
Baseband bus failure 3020: EFaultId_BaseBandBusFailure Failure in replaceable baseband unit 3003: EFaultId_FbiaFailureAl
Related information
Fault view
Id:0900d805809549d0
©2014/6/4NokiaSolutionsandNetworks
OIC MCU Buffer Full 1/1
OIC MCU Buffer Full Fault ID and name Usedinproducts Detectingunit
2011:EFaultId_OIC_MCUBFullAl LTE FCM,FCT
Source
FCM, FCT
Meaning
The control message traffic between the modules is malfunctioning.
State
Start Cancel /
Unit status
Working
Unit status attributes
Effect
There is possibly no immediate effects on the BTS operation, but it might cause an optical interface alarm.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablegreen
Instructions
Check the alarms for the connected module.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d805809549dd
©2014/6/4NokiaSolutionsandNetworks
Optical interface buffer alarm 1/1
Optical interface buffer Fault ID and name Usedinproducts Detectingunit
alarm 2051: EFaultId_Muksu_BufferAl LTE FCM
Source
FCM, OptIF
Meaning
RP3 or Ethernet buffering is not working, and the buffer becomes full. The optical device malfunctions. The fault might be generated because of synchronization problems or incorrect initialization.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
Baseband bus RP3/RP3-01 traffic may not work correctly. The cell operation is degraded.
Reported alarms
7654CELLOPERATIONDEGRADED
LEDdisplay
Blinkingred 1. Depending on the optical interface, reset the module behind the optical interface that causes the alarm by blocking/unblocking it.
Instructions
2. If that does not clear the fault situation, replace the module behind the optical interface that causes the alarm. 3. If the System Module is the only alarm source, or replacing the RF Module does not clear the fault situation, replace the System Module that causes the alarm.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d805809549f5
©2014/6/4NokiaSolutionsandNetworks
Optical Interface Data/Control/Ethernet Buffer Full 1/1
Optical Interface Data/Control/Ethernet Buffer Full 2007: EFaultId_OIC_DBTxFullAl Fault ID and name
2008: EFaultId_OIC_CBRxFullAl 2009: EFaultId_OIC_CBTxFullAl 2010: EFaultId_OIC_EBFullAl
Usedinproducts Detectingunit
LTE FCM,FCT
Source
OptIF
Meaning
The RP3 or Ethernet buffering is not working, and the buffer becomes full. The optical device is malfunctioning. The fault might be generated because of synchronization problems or incorrect initialization.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect Reported alarms LEDdisplay
Baseband bus RP3 traffic to the RF Module is not working. Cell operation is degraded. 7654CELLOPERATIONDEGRADED Blinkingred 1. Swap the alarming and working links, and check where the alarm is reported now.
Instructions
2. If the alarming link remains the same, replace the System Module. 3. If the alarming link changes, replace the module behind that link.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d805809549dc
©2014/6/4NokiaSolutionsandNetworks
Optical Interface faulty 1/1
Optical Interface faulty Fault ID and name
Usedinproducts
Detectingunit
2000: EFaultId_OIC_TxAl 2001: EFaultId_OIC_PresAl LTE
FCM,FCT
Source
OptIF
Meaning
The Small Form Factor Pluggable (SFP) malfunction has occurred, or the SFP module is not physically present (there is no electrical connection). The SFP is a part of the fibre cable package.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
LED display
Instructions
The traffic between the System Module and the connected module is interrupted. The cell operation is faulty. If the fault is reported for primary optical interface, then connection to further radio modules in chain is affected what is indicated via fault 10:EfaultId_NoConnectionToUnitAl for each module. 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Stable red (optical interfaces 1-5 leds) 1. Check that the SFP (Small Form Factor Pluggable) is properly connected in the System Module. 2. Replace the SFP module.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d805809549d9
©2014/6/4NokiaSolutionsandNetworks
Oven oscillator clock missing 1/1
Oven oscillator clock missing Fault ID and name
1819:EFaultId_OcxoClkMissAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM,FCT
Source
FCM, FCT
Meaning
The output signal of the OXCO is missing and the FCM/FCT cannot deliver the 30.72 MHz System Clock required by the other units.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect Reportedalarms LEDdisplay
TheBTSisnotoperational. 7650BASESTATIONFAULTY Stablered 1. Block/unblock the System Module.
Instructions 2. Replace the System Module. Related faults
System Module failure 3000: EFaultId_SystemModuleFailure
Related information
Fault view
Id:0900d805809549ca
©2014/6/4NokiaSolutionsandNetworks
Oven oscillator heating failure 1/1
Oven oscillator heating failure Fault ID and name
1817: EFaultId_Ov_Osc_HeatAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM,FCT
Source
FCM, FCT
Meaning
The OCXO warm-up takes too long and the OCXO does not become active within a period of eight minutes from the power-on. The ambient temperature might also be too low or it changes too fast.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
The system clock frequency starts drifting and the air interface frequency accuracy starts to degrade. The BTS might work properly for a few days without an external reference but the network performance might start to decrease gradually.
Reportedalarms
7650BASESTATIONFAULTY
LEDdisplay Instructions
Related faults
Stablered Replace the alarming System Module.
System Module failure 3000: EFaultId_SystemModuleFailure
Related information
Fault view
Id:0900d805809549c2
©2014/6/4NokiaSolutionsandNetworks
Oven oscillator Missing Pulse 1/1
Oven oscillator Missing Pulse Fault ID and name
1820: EFaultId_OcxoPulseMissingAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM,FCT
Source
FCM, FCT
Meaning
The output signal of the OXCO has some problems and one or more clock pulses are missed.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect Reportedalarms LEDdisplay
TheBTSisnotoperational. 7650BASESTATIONFAULTY Stablered 1. Block/unblock the System Module.
Instructions 2. Replace the System Module. Related faults
System Module failure 3000: EFaultId_SystemModuleFailure
Related information
Fault view
Id:0900d805809549cb
©2014/6/4NokiaSolutionsandNetworks
Parallel RP3-01 link length mismatch 1/1
Parallel RP3-01 link length mismatch Fault ID and name Usedinproducts Detectingunit
4072: E FaultId_ParallelLinkDifferenceTooLargeAl LTE FCM
Source
OptIF
Meaning
- The parallel RP3-01 links towards one radio module have too large mutual length difference (more than 60 meters). The main link is considered as a reference and the secondary link is compared to the main link. - RF sharing has been disabled on master WCDMA.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Nocommissionedcellsareactivated. 7651 BASE STATION OPERATION DEGRADED
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LEDdisplay
Instructions
Stablered Replace parallel RP3-01 fiber links towards one radio module so that the maximum mutual length difference between fibers is less than 60 meters. In case the fault is triggered because of incorrect RF sharing configuration check that RF sharing feature is enabled on synchronization master system module.
Related faults
Related information
Fault view
Id:0900d80580954a29
©2014/6/4NokiaSolutionsandNetworks
Peer system module connection lost 1/1
Peer system module connection lost Fault ID and name Usedinproducts Detectingunit
4110: EFaultId_PeerSystemModuleConnectionLostAl LTE FCM,FCT
Source
FCM, FCT
Meaning
The master system module has lost optical connection to the peer system module.
State
Start Cancel /
Unit status
Working
Unit status attributes
The master system module works properly.
Effect
None
Reported alarms
7652BASESTATIONNOTIFICATION
LED display Instructions
N/A Check the optical connection between master and peer system modules.
Related faults
Related information
Fault view
Id:0900d80580954a3b
©2014/6/4NokiaSolutionsandNetworks
Phich Power Boost not applied 1/1
Phich Power Boost not applied Fault ID and name Usedinproducts Detectingunit
6112: EFaultId_PhichPowerBoostAl LTE FSM
Source
FSP
Meaning
Configured PHICH transmission power boost cannot be applied either partly or at all due to a lack of remaining power after considering (boosted) cell-specific DL RS power, (boosted) PCFICH power and minimum reserved power for PDCCH.
State
Transient
Unit status
Working
Unit status attributes Effect Reportedalarms LED display Instructions
PHICH transmission power is not boosted enough or at all compared to operator's setting. 7655CELLNOTIFICATION None PHICH (Physical HARQ Indication Channel) transmission power boost can be increased by reducing the configured boosts for cell-specific downlink reference signal and/or PCFICH.
Related faults
Related information
Fault view
Id:0900d80580954a28
©2014/6/4NokiaSolutionsandNetworks
Pipe dangerously overheating 1/1
Pipe dangerously overheating Fault ID and name Usedinproducts Detecting unit
1938: E FaultId_FrPipeOverheat LTE FR
Source
TX1-n
Meaning
The validated temperature of any PA sensor is higher than or equal to the predefined value on unit property file.
State
Start Cancel /
Unitstatus
Outoforder;Degraded
Unit status attributes
Degraded - Validated temperature of any PA sensor is greater than or equal to Tdanger (when any TX/RX resources are available on alarming FRM) Out of order - dangerously high temperature occurs longer than tT+danger and PA is turned off (when no RX/TX resources are available on alarming FRM)
Effect
There can be problems with calls made through the affected cell(s).
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Blinking red (FR unit status: degraded), Stable Red (FR unit status: out of order)
Instructions
1. Check the fans and ensure that the ambient temperature on the site is acceptable. 2. If that does not help, replace the alarming RF Module.
Related faults
Temperature alarm 3040: EFaultId_TemperatureAlarm
Related information
Fault view
Id:0900d80580a467c2
©2014/6/4NokiaSolutionsandNetworks
POST test failed 1/1
POST test failed Fault ID and name
69: EFaultId_Post_test_failedAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT,FT
Source
FSP,DSP,FT,FCM/FCT
Meaning
The unit or module has been tested during the BTS power-on self test (POST) and a failure has been detected.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LED display
Because the faulty FSP is not configured, the BTS capacity decreases or the BTS is faulty. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED Stable red ( 7650) , Blinking red ( 7651) FlexiBTS: 1. Block/unblock the alarming unit/module.
Instructions
2. Remove/reinsert the alarming unit/module. 3. Replace the alarming unit/module.
Related faults
System Module failure 3000: EFaultId_SystemModuleFailure
Related information
Fault view
Id:0900d80580954a54
©2014/6/4NokiaSolutionsandNetworks
Power level not supported 1/1
Power level not supported Fault IDa nd name Usedinproducts Detectingunit
4008:E FaultId_PowerLevelNotSupportedAl LTE FSM
Source
LCR
Meaning
The power level defined in the RNW file is not supported by the HW.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Cellsremaindown.
Reportedalarms
7653CELLFAULTY
LEDdisplay
Stablegreen
Instructions
Define a valid TX power level value in the Radio Network configuration file (RNW) and use the Commissioning Wizard in BTS Site Manager to send the file to the BTS.
Related faults
Configuration error: 3070: EFaultId_ConfigurationError
Related information
Fault view
Id:0900d805809549fd
©2014/6/4NokiaSolutionsandNetworks
PPS reference missing 1/1
PPS reference missing Fault ID and name
1898:EFaultId_PpsRefMissAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FCM/FCT
Meaning
The reference clock monitoring has detected a loss of PPS signal in the reference received from the GPS receiver.
State
Start Cancel /
Unitstatus
Degraded;Working
Unit status attributes
Working: -other valid clock reference source is available Degraded: -otherwise
Effect
If other references are available, the synchronization reference source changes to another source, the tuning follows this new reference. If other references are not available, tuning does not follow the external reference any more. Clock tuning is halted and the BTS continues its operation based on the internal oven oscillator. If the FCM [FSMr3: FCT] is approaching the end of its lifetime but the reference frequency is still correct, the BTS and system performance might be normal for months or even one year after the alarm activation (provided that the DAC is not at the edge of the adjustment area).
Reported alarms
7651 BASE STATION OPERATION DEGRADED 7652 BASE STATION NOTIFICATION
LED display
Blinking red (7651); Stable green (7652) 1. Check the GPS receiver installation.
Instructions
2. Check the GPS receiver status. 3. Check the connection between the GPS receiver and FSM.
Related faults
BTS reference clock missing 3080: EFaultId_BtsReferenceClockMissing
Related information
Fault view
Id:0900d80580a38d95
©2014/6/4NokiaSolutionsandNetworks
Radio master conflict 1/1
Radio master conflict Fault ID and name Usedinproducts Detectingunit
4038: EFaultId_RadioMasterConflictAl LTE FCM
Source
FR
Meaning
FSM should be the radio master for RFSW, but notices that RFSW already has another radio master defined.
State
Start
Unit status
Degraded
Unit status attributes
Effect
This fault can prevent BTS from functioning when the RF Module is needed for the required cell configuration.
Reported alarms
7651BASESTATIONOPERATIONDEGRADED
LEDdisplay
Blinkingred
Instructions
Commissioning error. Only one System Module can be set as master for a particular radio resource.
Related faults
Commissioning error: 3060: EFaultId_CommissioningError
Related information
Fault view
Id:0900d80580954a17
©2014/6/4NokiaSolutionsandNetworks
Radio resources switched off 1/1
Radio resources switched off Fault ID and name
4057: EfaultId_RfSwitchedOffAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM
Source
Antenna line
Meaning
The cells, whose TX carriers are served by the affected Antenna Lines are deactivated to reduce the power transmitted by the Power Amplifier in Radio Module. This is to protect the Power Amplifier against a HW failure that might result from operating under excessive VSWR value condition (antenna line impedance mismatch).
State
Start
Unit status
Working
Unit status attributes Effect
Reported alarms
Theaffectedcellsaredisabled. 7652 BASE STATION NOTIFICATION 7655 CELL NOTIFICATION
LED display
Stable red (7653, RF state faulty), Blinking red (7653, RF state degraded), Stable green (7655)
Instructions
1. Check the antenna lines: antennas, antenna cables, connector torques and antenna line devices. 2. Check the antenna line (TX-cable-antenna) impedance matching.
Related faults
Related information
Fault view
Id:0900d80580a56fb1
©2014/6/4NokiaSolutionsandNetworks
Receiving failure in Optical Interface 1/1
Receiving failur e in Optical Interface FaultID and name Usedinproducts Detectingunit
2002:EFaultId_OIC_RxAl LTE FCM,FCT
Source
OptIF
Meaning
The incoming optical signal to the Small Form Factor Pluggable (SFP) is missing, too weak, or the fibre cable has been detached. The connection between the System Module and the RF Module units (Linear Transceiver, Antenna Filter or Antenna Line Device) is broken.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
LED display
The cell(s) of the RF Module behind the broken connection are not operational and the RF Module cannot be used. 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Stable red (appropriate OptIF led 1-5) 1. Check the status of the module behind the faulty link (power on, and so on).
Instructions
2. Check the SFP (Small Form Factor Pluggable) from both ends (the System Module and the module behind the faulty link). The optical interface LED indicates the faulty SFP. Replace the SFP if it is faulty. 3. Clean the connectors, test the fiber cable, and replace it if faulty. 4. If the previous steps do not help, replace the module behind the faulty link.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d805809549da
©2014/6/4NokiaSolutionsandNetworks
RET Antenna control failure 1/1
RET Antenna control failure 1842: EFaultId_MotorJamAl 1843: EFaultId_ActuatorJamAl Fault ID and name
1844: EFaultId_NotCalibratedAl 1845: EFaultId_NotConfiguredAl 1846: EFaultId_ActuatorInterferenceAl
Usedinproducts Detectingunit
LTE TILT
Source
TILT
Meaning
Antenna tilting is not possible or might function incorrectly.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
TheBTScapacitypossiblydecreases. 7652 BASE STATION NOTIFICATION
Reported alarms
7654 CELL OPERATION DEGRADED
LED display
Alternating red and green (RF module working, MHA faulty) 1. Recalibrate the RET antenna.
Instructions 2. If that does not help, replace the RET unit. Related faults
Related information
Fault view
Id:0900d805809549cc
©2014/6/4NokiaSolutionsandNetworks
RF Module blocked 1/1
RF Module blocked FaultID and name Usedinproducts Detectingunit
1931:E FaultId_FrBlocked LTE FRx/LTX
Source
LTX
Meaning
Ashared(Medusa)FRisblocked.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
LEDdisplay Instructions
It is not possible to establish phone calls through the blocked FR. The BTS does not send faults related to the blocked Flexi Radio module (FR) to the network management system (NMS). Fault sending to BTS Site Manager is always enabled. The fault cancels are always sent to the NMS. 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Stablered Unblockthealarmingmodule.
Related faults
Related information
Fault view
Id:0900d80580954a0f
©2014/6/4NokiaSolutionsandNetworks
RF Module failure 1/2
RF Module failure Fault ID and name Usedinproducts Detectingunit
3010:E FaultId_RfModuleFailure LTE FSM,FR
Source
FR
Meaning
The FlexiBTS has detected an abnormal operation or a failure in the internal functionality of the RF Module.
State
Start Cancel /
Unit status
N/A
Unit status attributes
Effect
Depending on the reported alarms, the BTS capacity might have decreased (CELL OPERATION DEGRADED or CELL FAULTY). 7652 BASE STATION NOTIFICATION
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
N/A Note: Perform the steps below in the listed order until the BTS fault disappears.
Instructions
1. Block/unblock RF HW unit. 2. If problem is still observed after step 1 replace RF HW unit. Low noise amplifier failure 1839: EFaultId_LNAFailureAl Filter unit operation failed 1840: EFaultId_TuningFailureAl 1841: EFaultId_UnitFaultyAl 4043: EFaultId_TuningFrequencyOutOfRangeAl RF Module configuring failed 1900: EFaultId_FrConfiguringFailed RF Module critical file not found 1901: EFaultId_FrCriticalFileNotFound RF Module file not found 1902: EFaultId_FrFileNotFound TX out of order 1907: EFaultId_FrTxOutOfOrder RF Module Gain adjusting failure 1908: EFaultId_FrGainAdjust
Related faults
RF Module Filter input power missing
RF Module failure 2/2
_ RX out of order 1911: EFaultId_FrRxOutOfOrder RF Module out of order 1912: EFaultId_FrOutOfOrder No feedback signal 1920: EFaultId_FrNoFeedBackSignal Unit unidentified 1923: EFaultId_FrUnitUnidentified Configuration file corrupted 1924: EFaultId_FrConfigurationFileCorrupted Post test failed 1925: EFaultId_FrPostTestFailed FPGA SW update failed 1928: EFaultId_FrFpgaSwUpdateFailed Antenna Carrier configuration failure 6259: EFaultId_AntennaCarrierMessageFailed
Related information
Fault view
Id:0900d80580a56f85
©2014/6/4NokiaSolutionsandNetworks
RF module filter input power missing 1/1
RF module filter input power missing Fault ID and name Usedinproducts Detectingunit
1910: EFaultId_FrFilterInputPowerMissing FlexiBTS FRx/LTX
Source
TX1-n
Meaning
TheRFModulefilterhasmeasuredtoolowTXpower.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LED display
Calls are not possible through the affected cell(s). 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Stable red (all Antenna Lines of the RF module are faulty); Blinking red (not all Antenna Lines of the RF module are faulty) 1. Block/unblock the RF Module.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d8058095b9df
©2014/6/4NokiaSolutionsandNetworks
RF Module Gain adjusting failure 1/1
RF Module Gain adjusting
failure
Fault ID and name
1908:E FaultId_FrGainAdjust
Usedinproducts
FlexiBTS,LTE
Detectingunit
FRx/LTX
Source
TX1-n
Meaning
TheTXoutputpoweradjustmentfailed.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
There might be problems in the calls through the affected cell(s).
Reported alarms
7654CELLOPERATIONDEGRADED
LEDdisplay
Blinkingred 1. Block/unblock the RF Module.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d805809549d3
©2014/6/4NokiaSolutionsandNetworks
RF module power output faulty 1/1
RF module power output faulty Fault ID and name
1918: E FaultId_FrPowerOutputFault
Usedinproducts
FlexiBTS,LTE
Detecting unit
FR
Source
FR, TX1-n
Meaning
The Power Supply has detected an overvoltage, undervoltage or overcurrent in the RF Module.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LED display
The TX part is out of power and calls are not possible through the affected cell(s). 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Stable red (all activated antenna-carriers faulty); Blinking red (at least one activated antenna-carrier faulty or degraded ) 1. Block/unblock the RF Module.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d8058095b9e0
©2014/6/4NokiaSolutionsandNetworks
Power on #smodLogicalId #pwrLineId line switched off remotely by user 1/1
Power on #smodLogicalId #pwrLineId line switched off remotely by user FaultI Da ndn ame
4107:EFaultId_RfPowerSwitchedOffFromBtsSmAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM,FCT
Source
FCM, FCT
Meaning
Power feeding for given Radio Module has been switched off by user from BTS Site Manager remotely.
State
Start Cancel /
Unit status
Working
Unit status attributes Effect
Radio module is powered off, therefore, calls/data transfers cannot be served by that module.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay Instructions
Stablegreen Enable power feeding towards Radio Module by switching RF power on in BTS Site Manager.
Related faults
Related information
Fault view
Id:0900d80580954a3a
©2014/6/4NokiaSolutionsandNetworks
RNW parameter mismatch 1/1
RNW parameter mismatch Fault ID and name
1896:EFaultId_RnwParameterMismatchAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCMFCT /
Source
FlexiBTS:FCM(FSMr2)/FCT(FSMr3)
Meaning
The RNW configuration data contains a request to create a cell for a non-existing LCR: the LCR ID parameter associated with the object cell does not exist.
State
Start Cancel /
Unit status
Working
Unit status attributes Effect
The BTS resumes the startup but the cells assigned to non-existing LCR IDs are discarded.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Instructions
Stablegreen 1. Check that each cell object is assigned to an existing LCR ID in the Configuration file and make corrections if necessary. 2. Download the corrected Configuration file and reset BTS.
Related faults
Commissioning error: 3060: EFaultId_CommissioningError
Related information
Fault view
Id:0900d805809549f9
©2014/6/4NokiaSolutionsandNetworks
RP3-01 Link Conflict 1/1
RP3-01 Link Conflict Fault ID and name Usedinproducts Detectingunit
4039: E FaultId_Rp301LinkConflictAl LTE FCM
Source
OptIF
Meaning
FSM notices that a shared radio module is connected to different OptIF connectors on peer system modules.
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Effect
This fault can prevent BTS from functioning when the RF Module is needed for the required cell configuration.
Reported alarms
7651BASESTATIONOPERATIONDEGRADED
LEDdisplay
Blinkingred
Instructions
RP3-01 cabling from peer system modules to shared radio module is to be corrected.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d80580954a18
©2014/6/4NokiaSolutionsandNetworks
S1 interface setup failure 1/1
S1 interface se tup f ailure Fault ID and name
6308:E FaultId_S1SetupRetryOut
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM,FCT
Source
LNMME
Meaning
There is no S1 connectivity to an MME, the MME has failed, and so on. If the fault is cancelled, autonomous recovery actions (reset) solved the fault situation.
State
Start Cancel /
Unitstatus
Outoforder;Degraded
Unit status attributes
Unit status is Degraded if at least one other S1 interface is operational, or else the Unit status is Out of order.
Effect
The S1 interface is not available for call setup and existing calls are released.
Reported alarms
LED display
Instructions
7656 BASE STATION CONNECTIVITY LOST 7657 BASE STATION CONNECTIVITY DEGRADED N/A Note: Perform the steps below in the listed order until the alarm disappears: 1. Check availability of MME. 2. Check other faults on MME and BTS. 3. Check the parameters related to S1 interface in the BTS and MME. 4. Reset the BTS.
Related faults
Related information
Fault view
Id:0900d80580a38d97
©2014/6/4NokiaSolutionsandNetworks
S1 interface recovery failure 1/1
S1 interface recovery failure Fault ID and name Usedinproducts Detectingunit
6317:E FaultId_S1ResetRetryOut LTE FCM,FCT
Source
LNMME
Meaning
S1 interface reset has failed after several attempts. This indicates that a severe failure has occurred, for example there is some configuration problem, there is no S1 connectivity, MME has failed, and so on.
State
Start Cancel /
Unitstatus
Outoforder;Degraded
Unit status attributes
Unit status is Degraded if at least one other S1 interface is operational, or the Unit status is Out of order
Effect
The S1 interface is unavailable and the BTS is not available for call setup.
Reported alarms
LED display
Instructions
7656 BASE STATION CONNECTIVITY LOST 7657 BASE STATION CONNECTIVITY DEGRADED N/A Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the availability of MME. 2. Check the connection with MME. 3. Disconnect and reconnect MME.
Related faults
Related information
Fault view
Id:0900d80580a38d99
©2014/6/4NokiaSolutionsandNetworks
S1 SCTP path failure 1/1
S1 SCTP path failure Fault ID and name
6204: EFaultId_S1SctpPathAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
LNMME
Meaning
One of the transport paths (SCTP) in SCTP connection to MME has failed. Only applicable when SCTP multi-homing is supported. An alternate transport path is available to pursue operation.
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Effect
One of the transport paths(SCTP) in SCTP connection to MME has failed. Only applicable when SCTP multi-homing is supported. An alternate transport path is available to pursue the operation.
Reported alarms
7657BASESTATIONCONNECTIVITYDEGRADED
LED display Instructions
N/A 1. Check whether the transport path is alive. 2. Check the configuration of transport addresses at MME.
Related faults
Related information
Fault view
Id:0900d80580954a03
©2014/6/4NokiaSolutionsandNetworks
SRAM operation failure 1/1
SRAM operation f ailure Fault ID and name
1875: EFaultId_SRAMRdAl 1876: EFaultId_SRAMWrAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
FSM
Meaning
The SRAM memory operation failure. If this fault appears continuously, the SRAM chip might be broken.
State
Start
Unit status
Degraded
Unit status attributes Effect
The BTS functionality is degraded and/or resources are unavailable.
Reported alarms
7651BASESTATIONOPERATIONDEGRADED
LEDdisplay
Instructions
Related faults
Blinkingred 1. Check the other active faults. 2. Replace the alarming module.
System Module failure 3000: EFaultId_SystemModuleFailure
Related information
Fault view
Id:0900d805809549e9
©2014/6/4NokiaSolutionsandNetworks
SRIO chain configuration was rejected 1/1
SRIO chain configu ration w as rejecte d Fault ID and name
4015: EFaultId_Srio_ConfFailedAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
FSPC
Meaning
The baseband bus related SRIO configuration for Faraday core was rejected by the platform SW.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
LEDdisplay
The BTS does not function correctly. Some BB processing resources in the BTS are out of use. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED Stablered
Instructions
Replacethealarmingunit.
Related faults
Baseband bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d80580954a01
©2014/6/4NokiaSolutionsandNetworks
Starting temperature below minimum 1/1
Starting temperature below minimum Fault IDa nd name Usedinproducts Detectingunit
1827:EFaultId_StartTempBelowMinAl LTE FCM
Source
BTS
Meaning
The temperature measured from sensor specified in "Temp.Cold.Start.Sensor" (= FSP) is less than "Temp.Cold.Start.Limit" The BTS cannot start properly, because the FSPs cannot be powered up at too cold conditions.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect Reportedalarms LEDdisplay
TheBTScannotstarttotheoperationalstate. 7650BASESTATIONFAULTY Stablered 1. Wait until the module is automatically heated to the required start-up temperature.
Instructions
Related faults
2. If the fault has been active for more than 2 hours, check the environmental conditions of the site. Temperature alarm 3040: EFaultId_TemperatureAlarm
Related information
Fault view
Id:0900d80580a38da7
©2014/6/4NokiaSolutionsandNetworks
Summing service default initialization failed 1/1
Summing service default initialization failed Fault ID and name Usedinproducts Detectingunit
4092: EFaultId_MurkkuDefaultInitFailedAl LTE FCT
Source
FCT
Meaning
Summing service default configuration has failed.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect Reportedalarms LEDdisplay
BTSisnotoperational. 7650BASESTATIONFAULTY Stablered 1. Reset the System Module.
Instructions 2. If a reset does not resolve the fault situation, replace the System Module. Related faults
System Module failure 3000: EFaultId_SystemModuleFailure
Related information
Fault view
Id:0900d80580954a36
©2014/6/4NokiaSolutionsandNetworks
Summing service release from reset failed 1/1
Summing service release from reset failed Fault ID and name Usedinproducts Detectingunit
4081: E FaultId_MurkkuReleaseFromResetFailedAl LTE FCT
Source
FCT
Meaning
Summingservicereleasefromresetfailed.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect Reportedalarms LEDdisplay
BTSisnotoperational. 7650BASESTATIONFAULTY Stablered 1. Reset the System Module.
Instructions 2. If a reset does not resolve the fault situation, replace the System Module. Related faults
Related information
Fault view
Id:0900d80580954a35
©2014/6/4NokiaSolutionsandNetworks
SW corrupted 1/1
SW corrupted Fault ID and name
Usedinproducts
Detectingunit
1850: EFaultId_SwCorruptedAl 4029: EFaultId_SwCorruptedPermanentAl LTE
FCM/FCT
Source
Filter,FR,FTM/FCT
Meaning
A corrupted SW file in the FLASH has been detected. Unit cannot complete start-up.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
The module might have been started with an old SW version and is, therefore, not compatible with other modules. 7650 BASE STATION FAULTY
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LEDdisplay
Blinkingred
Instructions
UpdatetheSWtotheBTS.
Related faults
BTS internal SW management problem 3090: EFaultId_BtsInternalSwManagementProblem
Related information
Fault view
Id:0900d805809549c3
©2014/6/4NokiaSolutionsandNetworks
SW fallback 1/1
SW fallback 4082: EfaultId_FallbackDueToMaxResetLoopCounterValueAl Fault ID and name
4083: EFaultId_FallbackDueToConfigurationDataMigrationFailureAl 4085: EfaultId_FallbackDueToTransportRequestAl
Usedinproducts
LTE
Detectingunit
FSMr2:FCM,FSMr3:FCT
Source
4082: FSMr2: FCM, FSP MCU FSMr3: FCT 4083: FSMr2: FCM FSMr3: FCT 4085: (for FSMr3 only) FSMr3: FCT
Meaning
4082: Source unit reached maximum number of reset retries, that is, source unit cannot finish successfully start-up after SW update. 4083: Source unit requests SW fallback because of critical problem which occurred in start-up after SW update, that is, configuration data migration failure. 4085: Transport SW on source unit indicates need for software fallback.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
SourceunithasinconsistentSWversion. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
LED display
Stable red (7650), Blinking red (7651)
Instructions
In case BTS is not automatically updated by NetAct: Update SW to the BTS with SW version running on BTS before SW update causing SW fallback.
Related faults
Related information
Fault view
Id:0900d80580954a2d
©2014/6/4NokiaSolutionsandNetworks
Synchronization error in RP1 receiver 1/1
Synchronization error in RP1 receiver Fault ID and name
Usedinproducts
Detectingunit
2048: EFaultId_Casa2Rp1CrcAl 2049: EFaultId_Casa2Rp1FramePhaseAl LTE
FCM
Source
FSM
Meaning
The frame alignment is lost or the frame burst has a CRC error when the System Module is working as a synchronization slave system module.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect Reportedalarms LEDdisplay
The SystemModule isoutof order and theBTSis out of order. 7650BASESTATIONFAULTY Stablered
Instructions
1. Check the RP3-01 cable between the synchronization master and synchronization slave system modules. 2. Check alarms in the synchronization master system module and act accordingly. 3. Reset the synchronization master system module.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d805809549e8
©2014/6/4NokiaSolutionsandNetworks
Synchronization failure in Optical Interface 1/1
Synchronization failure in Fault ID and name Usedinproducts Detectingunit
Optical Interface < opt l ink/RP 3 link> 2005: EFaultId_OIC_SyncChAl LTE FCM,FCT
Source
OptIF
Meaning
The RP3 channel lost the frame synchronization state that it had achieved.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
RP3 traffic to the connected RF Module is malfunctioning. The related cell(s) are not operational.
Reportedalarms
7653CELLFAULTY
LEDdisplay
Stablered(SFPled) 1. Swap the alarming and working links, and check where the alarm is reported now.
Instructions
2. If the alarming link remains the same, replace the System Module. 3. If the alarming link changes, replace the module behind that link.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d805809549db
©2014/6/4NokiaSolutionsandNetworks
System information broadcast parameters overflow 1/1
System information broadcast parameters overflow Fault ID and name Usedinproducts Detectingunit
6351: EFaultId_SystemInfoValueTagHandlingFailed LTE FSP
Source
LCR
Meaning
System Information Broadcast related parameters have changed more than 32 times within 3 hours.
State
Transient
Unit status
Working
Unit status attributes
Effect
Some of the UEs with a complete set of system information of the cell stored that has left cell and has come back within 3 hours of time might not recognize that there was a system information change.
Reportedalarms
7655CELLNOTIFICATION
LEDdisplay
Stablegreen
Instructions
Note! This fault does not require any (special) actions.
Related faults
Related information
Fault view
Id:0900d8058095b9e1
©2014/6/4NokiaSolutionsandNetworks
System Module failure 1/2
System Module failure Fault ID and name
3000:E FaultId_SystemModuleFailure
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
FSM
Meaning
The FlexiBTS has detected an abnormal operation or a failure in the internal functionality of the System Module.
State
Start Cancel /
Unit status
N/A
Unit status attributes
Effect
Reported alarms
LED display
Depending on the reported alarms, the BTS capacity might have decreased (BASE STATION OPERATION DEGRADED) or the BTS might be not operational at all (BASE STATION FAULTY). 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED N/A Note: Perform the steps below in the listed order until the BTS fault disappears.
Instructions
1. Reset the System Module. 2. Replace the System Module. No connection to unit 10: EFaultId_NoConnectionToUnitAl Unit synchronization failed 16: EFaultId_SynchronizationAl POST test failed 69: EFaultId_Post_test_failedAl Oven oscillator heating failure 1817: EFaultId_Ov_Osc_HeatAl Oven oscillator clock missing 1819: EFaultId_OcxoClkMissAl
Related faults
Oven oscillator Missing Pulse 1820: EFaultId_OcxoPulseMissingAl Communication failure 1806: EFaultId_CommunicationFailureAl SRAM operation failure 1875: EFaultId_SRAMRdAl 1876: EFaultId_SRAMWrAl PLL status not locked 4010: EFaultId_PLLStatusNotLockedAl Master unit has lost connection to the slave unit 4019: EFaultId_KeepAliveStatusErrorAl Internal MTU configuration failure 4025: EFaultId_MtuConfigurationFailureAl
Related information
Fault view
System Module failure 2/2
Id:0900d80580a5fc55
©2014/6/4NokiaSolutionsandNetworks
Technical log buffer freezing 1/1
Technical log buffer freezing Fault ID and name Usedinproducts Detectingunit
6450: E FaultId_TechnicalLogUploadRecommended LTE FSP;FSM
Source
FSP; FSM
Meaning
The technical log buffer has been frozen in the BTS for an internal reason.
State
Transient
Unit status
Working
Unit status attributes Effect
ThisfaulthasnoeffectonBTSoperation.
Reported alarms
7652BASESTATIONNOTIFICATION
LED display Instructions
None This fault does not require any actions.
Related faults
Related information
Fault view
Id:0900d80580954a1d
©2014/6/4NokiaSolutionsandNetworks
Temperature alarm 1/2
Temperature alarm Fault ID and name
3040: EFaultId_TemperatureAlarm
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM,FR
Source
FSM, FR
Meaning
The internal temperature of the RF Module or System Module exceeds the threshold value, or the ambient temperature of the module(s) is beyond the specified limits.
State
Start Cancel /
Unit status
N/A
Unit status attributes
Effect
Depending on the reported alarms, the fault situation might have no impact on the operation (BASE STATION NOTIFICATION), the BTS capacity might have decreased (CELL OPERATION DEGRADED, or CELL FAULTY)) or the BTS might not be operational at all (BASE STATION FAULTY). 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
Reported alarms
7652 BASE STATION NOTIFICATION 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED 7655 CELL NOTIFICATION
LED display
N/A Note: Perform the steps below in the listed order until the BTS fault disappears. 1. Check the other BTS faults and act accordingly.
Instructions
2. Check the ambient temperature of the BTS/modules. If the ambient temperature is too high, make sure the airflow to the BTS modules is unobstructed, that is, the BTS modules are not covered with anything. If the ambient temperature is too low, it takes a while for the BTS/modules to heat themselves to the threshold value. 3. Reset the alarming module by blocking/unblocking it. 4. Replace the alarming module. Unit temperature is high 2: EFaultId_UnitOverheatAl Starting temperature below minimum 1827: EFaultId_StartTempBelowMinAl RF Module Overheat 1913: EFaultId_FrOverheat
Related faults
RF Power decreased 1927: EFaultId_FrPowerDecreased Unit (module) temperature is high 1936: EFaultId_FrTempHigh Module dangerously overheating 4071: EFaultId_SysDangerouslyOverheatAl FSP overheating 4077: EFaultId_FspOverheatingAl
Related information
Temperature alarm 2/2
Fault view
Id:0900d805809549ed
©2014/6/4NokiaSolutionsandNetworks
Temperature too low (Heating ongoing) 1/1
Temperature too low (Heating ongoing) Fault ID and name Usedinproducts Detectingunit
1922: E FaultId_FrTemperatureTooLow LTE FRx/LTX
Source
LTX
Meaning
During RF startup: The temperature inside the RF Module is too low. Heating of module is ongoing. Wait until the alarm is canceled. This might take up to 30 minutes. During RF runtime: The temperature inside the RF module is going too low. Problem might occur.
State
Start Cancel /
Unitstatus
Outoforder;Working
Unit status attributes
Out of order during RF startup Working during RF runtime
Effect
This fault should cancel itself. Heating of the module is ongoing. During RF startup affected cell resources are not reported to RROM. 7653 CELL FAULTY
Reported alarms
7654 CELL OPERATION DEGRADED 7655 CELL NOTIFICATION
LEDdisplay
Stablered(7653) During RF startup only:
Instructions
1. Heating of module is ongoing. Wait until the alarm is canceled. This might take up to 30 minutes. 2. If that does not help, block/unblock the RF Module. 3. If that does not help, replace the alarming RF Module.
Related faults
Related information
Fault view
Id:0900d805809549d5
©2014/6/4NokiaSolutionsandNetworks
Toggling: 1/1
Toggling: Fault ID and name Usedinproducts Detectingunit
4026: EFaultId_TogglingAl LTE FSM
Source
FSM, FR
Meaning
BTS Fault, which fault name is mentioned in the Fault name -field, is toggling in the BTS. Toggling alarm condition is informed to user with this new BTS Fault. Toggling alarms are suppressed until the toggling alarm condition is cleared. Severity of this BTS Fault is the same as the severity of the toggling BTS Fault.
State
Start Cancel /
Unit status
N/A
Unit status attributes
Effect
Depending on the reported alarm, the fault situation might have no impact on the operation (BASE STATION or CELL NOTIFICATION), the BTS capacity might have decreased (BASE STATION or CELL OPERATION DEGRADED, or CELL FAULTY), or the BTS might not be operational at all (BASE STATION FAULTY). 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED 7652 BASE STATION NOTIFICATION
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED 7655 CELL NOTIFICATION 7656 BASE STATION CONNECTIVITY LOST
LED display
N/A 1. Check the fault name of the toggling BTS fault.
Instructions
2. Follow the instructions of the toggling BTS fault to clear the problem. Note! Detailed information about the toggling frequency can be found in alarm history file, which can be downloaded using BTS Site Manager. The log file is available with Snapshot."
Related faults
Related information
Fault view
Id:0900d80580954a0e
©2014/6/4NokiaSolutionsandNetworks
Transmission clock missing 1/1
Transmission clock missing Fault ID and name Usedinproducts Detectingunit
1816:E FaultId_Trans_Clk_MsgAl LTE FCM,FCT
Source
FCM, FCT
Meaning
The reference clock monitoring has detected a loss of signal in the reference received from the FT.
State
Start Cancel /
Unitstatus
Degraded;Working
Unit status attributes
Effect
Reported alarms
LEDdisplay
If other references are available, the synchronization reference source changes to another source. Tuning then follows this new reference. If other references are not available, the BTS master clock (OCXO) tuning is halted and the BTS synchronization drops to holdover mode. 7651 BASE STATION OPERATION DEGRADED 7652 BASE STATION NOTIFICATION Blinkingred 1. Check the Iub connection.
Instructions
2. Check the FT (Flexi Transport SubModule) status. 3. Check the connection between the FT and FSM (Flexi System Module).
Related faults
BTS reference clock missing 3080: EFaultId_BtsReferenceClockMissing
Related information
Fault view
Id:0900d80580a4674e
©2014/6/4NokiaSolutionsandNetworks
Transmission parameters missing 1/1
Transmission parameters missing Fault ID and name Usedinproducts Detectingunit
1825:EFaultId_PublicIPmissingAl LTE FCM/FCT
Source
FT, FCT
Meaning
A request to retrieve the public IP address information of the FCM/FCT from the FTM fails.
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Effect
The BTS is not commissioned or integrated to the network. The BTS cannot be accessed or configured remotely.
Reported alarms
7651BASESTATIONOPERATIONDEGRADED
LEDdisplay
Blinkingred
Instructions
Commission the BTS site with correct IP addresses.
Related faults
Commissioning error: 3060: EFaultId_CommissioningError
Related information
Fault view
Id:0900d805809549d1
©2014/6/4NokiaSolutionsandNetworks
Transport layer connection failure in S1 interface 1/1
Transport layer connection failure in S1 interface Fault ID and name
6202: EFaultId_S1SctpEndpointAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
LNMME
Meaning
The transport path (SCTP) for connection to MME has broken. The reason for this can be an unplugged cable to MME. No transport path available to pursue operation on the faulty connection with the MME.
State
Start Cancel /
Unitstatus
Outoforder;Degraded
Unit status attributes
Unit status is "Degraded" if the fault is on an S1 interface with at least one other S1 interface available for use. Unit status is "Out of Order" when all S1 interfaces are faulty.
Effect
S1 interface is unavailable. If there is no other S1 interface available for use then BTS operation is considered faulty and no calls can be setup. If there is at least one other S1 interface available for use then BTS operation is considered degraded and BTS can continue operation(that is setup calls) using available S1 interface(s). 7656 BASE STATION CONNECTIVITY LOST
Reported alarms LED display
Instructions
7657 BASE STATION CONNECTIVITY DEGRADED N/A Note: Perform the steps below in the listed order until the alarm disappears: 1. Check the connection with MME, based on whether the S1 link is broken accordingly. 2. Check if MME is operational. 3. Check if the speed and duplex setting of eNB S1 port is consistent with switch port which is connected directly to the eNB, for example both "Autodetect" or both "1000 Mbit/s Full duplex". If this fault happens right after a commissioning or a configuration change, verify the following configuration data: IP address of the MME.
Related faults
Related information
Fault view
Id:0900d80580a38db7
©2014/6/4NokiaSolutionsandNetworks
Transport layer connection failure in X2 interface 1/1
Transport layer connection failure in X2 interface Fault ID and name Usedinproducts Detectingunit
6203: EFaultId_X2SctpEndpointAl LTE FCM,FCT
Source
LNADJ
Meaning
The transport path (SCTP) for connection to an adjacent BTS has broken. The reason for this might be an unplugged cable to the adjacent BTS. No transport path available to pursue operation on the faulty connection with the adjacent BTS.
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Effect
X2 interface is unavailable. Handover of calls to or from cells of the associated adjacent BTS is not possible. Base station(BTS) operation is considered degraded.
Reported alarms
7657BASESTATIONCONNECTIVITYDEGRADED
LED display
Instructions
N/A Note: Perform the steps below in the listed order until the BTS Fault disappears: 1.Check the connection with adjacent BTS, based on whether the X2 link is broken respectively. 2. Check if the adjacent BTS is operational. If this fault happens right after a commissioning or a configuration change, verify the IP address of the adjacent BTS.
Related faults
Related information
Fault view
Id:0900d80580954a24
©2014/6/4NokiaSolutionsandNetworks
TX failure in MIMO 1/1
TX failure in MIMO Fault ID and name
4003: EFaultId_TxFailureTurnMimoOffAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
LCR
Meaning
Because of TX path failure MIMO (Multiple Input Multiple Output) functionality is not operational or is degraded in the cell related to the faulty TX.
State
Start Cancel /
Unit status
Working
Unit status attributes
Effect
Because of TX failure MIMO (Multiple Input Multiple Output) functionality is not operational or degraded for the cell related to the faulty TX. An attempt of the operator to configure any other mode than the single TX mode for the cell will be unsuccessful in this case.
Reportedalarms
7655CELLNOTIFICATION
LEDdisplay
Stablegreen
Instructions
Software and hardware reconfiguration can be made, to the setup where faulty TX is not used. Then the cells will operate in the single mode unless all the TXes related to the proper cell are faulty. Check the other active BTS faults and act accordingly.
Related faults
Related information
Fault view
Id:0900d805809549fc
©2014/6/4NokiaSolutionsandNetworks
TX out of order 1/1
TX out of order Fault ID and name
1907: E FaultId_FrTxOutOfOrder
Usedinproducts
FlexiBTS
Detectingunit
FRx/LTX
Source
TX1-n
Meaning
TheRFModuleTXpathisnotusable.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LED display
Calls are not possible through the affected cell(s). 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Stable red (all Antenna Lines of the RF module are faulty); Blinking red (not all Antenna Lines of the RF module are faulty) 1. Block/unblock the RF Module.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d8058095b9de
©2014/6/4NokiaSolutionsandNetworks
Unit blocked 1/1
Unit blocked Fault ID and name
48:EFaultId_UnitBlockedAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
FR
Meaning
A module is blocked with BTS Site Manager. The purpose is to avoid fault indications that might be raised during the module maintenance task.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
The BTS does not send faults related to the blocked module to the network management system (NMS). The fault sending to BTS Site Manager is always enabled. The fault cancellations are always sent to the NMS. It is not possible to establish phone calls through the blocked module. 7652 BASE STATION NOTIFICATION
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LEDdisplay Instructions
Stableyellow Unblock themodulewithBTSSiteManager.
Related faults
Related information
Fault view
Id:0900d80580954a50
©2014/6/4NokiaSolutionsandNetworks
Unit initialization failure 1/1
Unit initialization failure Fault ID and name
12: EFaultId_TcomConfigAl 4040: EFaultId_InitFaultManAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FCM/FCT, FSP
Meaning
A module initialization has failed. OR Application of LTE505 feature-related transport network configuration or re-configuration has failed.
State
Start Cancel /
Unitstatus
Outoforder;Degraded
Unit status attributes
Status "degraded" is used for failure of LTE505 re-configuration during eNB runtime. Status "out of order" is used for failure of LTE505 configuration at eNB startup.
Effect
TheBTSisnotoperationalordegraded.
Reported alarms
LED display
7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
Stable red (7650), blinking red (7651) FlexiBTS: 1. Block/unblock the alarming module. 2. If FSP is the fault source, FSP reset recovery. If FCM/FCT is the fault source, system module reset recovery. If that does not help, perform a power-off reset.
Instructions
3. If Step 1 and 2 does not help, replace the alarming module. LTE505 specific case: Check the LTE505 related configuration. If the fault was raised at startup then correct the configuration and reset BTS. If the fault was raised during eNB runtime then correct the configuration and apply the changes at BTS.
Related faults
Configuration error: 3070: EFaultId_ConfigurationError
Related information
Fault view
Id:0900d80580a38db9
©2014/6/4NokiaSolutionsandNetworks
Unit (module) dangerously overheating 1/1
Unit (module) dangerously overheating Fault ID and name Usedinproducts Detectingunit
1937: E FaultId_FrDangerouslyOverheat LTE FR/RFSW
Source
RFSW
Meaning
Validated sensor temperature is greater than or equal to the predefined value on unit property file.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LEDdisplay
Calls are not possible through the affected cell(s) 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Stablered 1. Check the fans and ensure that the ambient temperature on the site is acceptable.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
Temperature alarm 3040: EFaultId_TemperatureAlarm
Related information
Fault view
Id:0900d80580954a15
©2014/6/4NokiaSolutionsandNetworks
Unit (module) temperature is high 1/1
Unit (module) tempera ture is hi gh Fault ID and name Usedinproducts Detectingunit
1936: EFaultId_FrTempHigh LTE FR/RFSW
Source
RFSW
Meaning
Validated module temperature is higher than the predefined maximuma llowed value.
State
Start Cancel /
Unit status
Working
Unit status attributes Effect
The RF Module may overheat, but there is no immediate effect on the module operation.
Reportedalarms
7655CELLNOTIFICATION
LEDdisplay
Stablegreen
Instructions
Check the fans and ensure that the ambient temperature on the site is acceptable.
Related faults
Temperature alarm 3040: EFaultId_TemperatureAlarm
Related information
Fault view
Id:0900d80580954a14
©2014/6/4NokiaSolutionsandNetworks
Unit not supported by current BTS SW version 1/1
Unit not supported by current BTS SW version Fault ID and name
95: EFaultId_NotSupportedUnit
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
Allpossibleunits.
Meaning
A non-supported unit has been detected in the System Module. Typically, this happens when a new unit version is installed while there is older System Module SW in use that does not support the new unit version.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
Depending on the reported severity, the BTS capacity might have decreased (BASE STATION OPERATION DEGRADED, CELL FAULTY) or the BTS might not be operational at all (BASE STATION FAULTY). For resources that are not in use (not commissioned) lack of support is reported by minor severity alarm (BASE STATION NOTIFICATION). 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
Reported alarms
7652 BASE STATION NOTIFICATION 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Stable red (7650), Blinking red (7651), N/A (7652, 7653)
Instructions
1. Upgrade the system module SW. 2. Replace the unit.
Related faults
Configuration error: 3070: EFaultId_ConfigurationError
Related information
Fault view
Id:0900d805809548b1
©2014/6/4NokiaSolutionsandNetworks
Unit SW download failed 1/1
Unit SW download f ailed FaultID and name
6:EFaultId_SwDownloadAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FCM/FCT,FSP,FR,Faraday/Nyquist
Meaning
Software update in the module or submodule has failed.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
If the FSP update fails, the BTS capacity drops. If the optical interface FPGA SW update fails, communication to radio modules does not work and the BTS is not operational. 7650 BASE STATION FAULTY
Reported alarms
7651 BASE STATION OPERATION DEGRADED 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Instructions
Related faults
Stable red ( 7650), Blinking Red ( 7651,7653) 1. Download the BTS SW again. 2. Reset (block/unblock) the BTS. 3. If Step 2 does not help, replace the alarming module.
BTS internal SW management problem 3090: EFaultId_BtsInternalSwManagementProblem
Related information
Fault view
Id:0900d805809549fa
©2014/6/4NokiaSolutionsandNetworks
Unit synchronization failed 1/1
Unit synchronization failed Fault ID and name
16: EFaultId_SynchronizationAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FCM/FCT,FSP,DSP
Meaning
FCM/FSPsynchronizationhasfailed.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
The BTS capacity possibly decreases. Some cells might become disabled. The BTS is out of order. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
LED display
Stable red (FCM/FCT on MSM or all FSPs); Blinking red (not all FSPs)
Instructions
1. Block/unblock the alarming module. 2. Replace the alarming module.
Related faults
System Module failure 3000: EFaultId_SystemModuleFailure
Related information
Fault view
Id:0900d80580954a4e
©2014/6/4NokiaSolutionsandNetworks
Unit temperature is high 1/1
Unit temperature is high Fault ID and name
2: EFaultId_UnitOverheatAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM,FCT
Source
FCM, FCT, FSP
Meaning
The temperature of a unit exceeds the threshold value.
State
Start Cancel /
Unit status
Working
Unit status attributes Effect
TheoperationoftheBTSpossiblydecreases.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Stablegreen
Instructions
Check the active fan alarms and the airflow of the BTS.
Related faults
Temperature alarm 3040: EFaultId_TemperatureAlarm
Related information
Fault view
Id:0900d80580a56f4d
©2014/6/4NokiaSolutionsandNetworks
Unknown HW resource 1/1
Unknown HW resource Fault ID and name
94:EFaultId_UnknownUnitType
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
-FSP(fixedandplug-incards)-FR-FTM-FF
Meaning
A unit cannot be identified by its product code or by its physical device address (object ID).
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
Depending on the reported severity, the BTS capacity might have decreased (BASE STATION OPERATION DEGRADED, CELL OPERATION DEGRADED, CELL FAULTY) or the BTS might be not operational at all (BASE STATION FAULTY). 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
Reported alarms
7652 BASE STATION NOTIFICATION 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display Instructions
Related faults
Stable red (7650), Blinking red (7651), N/A (7652, 7653, 7654) Replace the alarming unit/module.
Configuration error: 3070: EFaultId_ConfigurationError Failure in replaceable baseband unit 3003: EFaultId_FbiaFailureAl
Related information
Fault view
Id:0900d805809548b0
©2014/6/4NokiaSolutionsandNetworks
Unknown product code 1/1
Unknown product code Fault ID and name
93: EFaultId_UnknownProductCode
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FSM, FSP, FT, FR
Meaning
A module cannot be identified by its product code but is known by its physical device address (object_ID).
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
Depending on the reported severity, the BTS capacity might have decreased (BASE STATION OPERATION DEGRADED, CELL FAULTY, CELL OPERATION DEGRADED) or the BTS might not be operational at all (BASE STATION FAULTY). 7650 BASE STATION FAULTY
Reported alarms
7651 BASE STATION OPERATION DEGRADED 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display Instructions
Related faults
Stable red (7650,7653), Blinking red (7651, 7654) Replace the alarming module.
Configuration error: 3070: EFaultId_ConfigurationError
Related information
Fault view
Id:0900d805809548af
©2014/6/4NokiaSolutionsandNetworks
Validation of signed file failed 1/1
Validation of sig ned file failed Fault ID and name
4145: E FaultId_SignatureValidationFailedAl
Usedinproducts
FlexiBTS
Detectingunit
FCT
Source
FCT
Meaning
SW file validation against its signature failed.
State
Start Cancel /
Unitstatus
Outoforder;Working
Unit status attributes
Effect
Reported alarms
LEDdisplay Instructions
In case of problem detection in SW activation - the SW activation and consequent reset are aborted. In case of problem detection in Start-up, BTS remains out of order. Rollback to previous SW and another SW download must be requested by Customer. 7650 BASE STATION FAULTY 7652 BASE STATION NOTIFICATION Stable red (7650) Stable green (7652) Trigger SW update for BTS to the requested SW version.
Related faults
Related information
Fault view
Id:0900d80580a47c4e
©2014/6/4NokiaSolutionsandNetworks
VSWR major alarm 1/1
VSWR major alarm Fault ID and name
1837:EFaultId_VSWRMajorAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FlexiFilter,FR
Source
Antenna line
Meaning
VSWR value exceeds the defined level. The antenna line is mismatched or damaged.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
The cell is disabled. Downlink signal transmission on the given antenna line is disabled and corresponding FR transmitter is unusable. Thus, the overall FR state is affected. 7652 BASE STATION NOTIFICATION
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED 7655 CELL NOTIFICATION
LED display
Stable red (all Antenna Lines of the RF module are faulty); Blinking red (not all Antenna Lines of the RF module are faulty) 1. Check the antenna cables, connectors, antenna, and possible antenna line devices.
Instructions 2. Check the antenna line (TX-cable-antenna) impedance matching. Related faults
Related information
Fault view
Id:0900d80580a56f53
©2014/6/4NokiaSolutionsandNetworks
VSWR minor alarm 1/1
VSWR minor alarm Fault ID and name Usedinproducts Detectingunit
1838:EFaultId_VSWRMinorAl LTE FlexiFilter,FR
Source
Antennaconnector
Meaning
Radio Module (60W RRH)/the Filter (all others) has detected a VSWR value exceeding the defined level. The antenna line is slightly mismatched.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
The output power at the antenna is decreased and the antenna is not working optimally.
Reportedalarms
7653CELLFAULTY
LEDdisplay
Blinkingred 1. Check the antenna cables, connectors, antenna, and possible antenna line devices.
Instructions 2. Check the antenna line (TX-cable-antenna) impedance matching. Related faults
Related information
Fault view
Id:0900d80580a343ee
©2014/6/4NokiaSolutionsandNetworks
X2 interface recovery failure 1/1
X2 interface recovery failure Fault ID and name Usedinproducts Detectingunit
6303:E FaultId_X2ResetRetryOut LTE FCM,FCT
Source
LNADJ
Meaning
The X2 interface reset has failed after several attempts. This indicates that a severe failure has occurred, for example there is a configuration problem, there is no X2 connectivity, the adjacent BTS has failed, and so on.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
Handovers from or to cells of the related adjacent BTS are not possible.
Reported alarms
7657BASESTATIONCONNECTIVITYDEGRADED
LED display
Instructions
N/A Note: Perform the steps below in the listed order until the alarm disappears. 1. Check the availability of the adjacent BTS. 2. Check the connection with the adjacent BTS. 3. Disconnect and reconnect the adjacent BTS.
Related faults
Related information
Fault view
Id:0900d80580954a09
©2014/6/4NokiaSolutionsandNetworks
X2 interface setup failure 1/1
X2 interface se tup f ailure Fault ID and name Usedinproducts Detectingunit
6304:E FaultId_X2SetupRetryOut LTE FCM,FCT
Source
LNADJ
Meaning
There is no X2 connectivity to an adjacent BTS, the adjacent BTS has failed, and so on.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
Handovers to cells of the related adjacent BTS are not possible.
Reported alarms
7657BASESTATIONCONNECTIVITYDEGRADED
LED display
Instructions
N/A Note: Perform the steps below in the listed order until the alarm disappears. 1. Check connectivity to the related adjacent BTS. 2. Check other faults. 3. Check the parameters related to the X2 interface to the adjacent BTS. 4. Reset the BTS.
Related faults
Related information
Fault view
Id:0900d80580954a08
©2014/6/4NokiaSolutionsandNetworks
RF Power decreased 1/1
RF Power decreased Fault ID and name Usedinproducts Detectingunit
1927: EFaultId_FrPowerDecreased FlexiBTS FRM2/LTX
Source
TX1-n
Meaning
The highest temperature exceeds the power decrease limit.
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Effect
The TX power level is decreased and there can be problems in the phone calls through the affected cell(s).
Reported alarms
7654CELLOPERATIONDEGRADED
LEDdisplay
Blinkingred 1. Check the fans and ensure that the ambient temperature on the site is acceptable.
Instructions
2. If that does not help, block/unblock the alarming RF Module. 3. If that does not help, replace the alarming RF Module.
Related faults
Temperature alarm 3040: EFaultId_TemperatureAlarm
Related information
Fault view
Id:0900d8058097a446
©2014/6/4NokiaSolutionsandNetworks
Module Clock faulty 1/1
Module Clock faulty Fault ID and name
1926: E FaultId_FrModuleClockFaulty
Usedinproducts
FlexiBTS,LTE
Detecting unit
FR
Source
FR
Meaning
TheRFModulelostlocktotheincomingclock.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LED display
Callsarenotpossiblethrough theaffectedcells 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED N/A 1. Check the cables between the System Module and RF Module.
Instructions
2. Block/unblock the RF Module. 3. If that does not help, replace the alarming RF Module.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d8058097a445
©2014/6/4NokiaSolutionsandNetworks
No feedback signal 1/1
No feedback signal Fault ID and name Usedinproducts Detectingunit
1920: E FaultId_FrNoFeedBackSignal FlexiBTS FRx/LTX
Source
TX1-n
Meaning
The feedback signal to predistortion is too weak or missing. The TX performance is degraded.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
There can be problems in the calls through the affected cell(s).
Reported alarms
7654CELLOPERATIONDEGRADED
LEDdisplay
Blinkingred 1. Block/unblock the RF Module.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d8058097a444
©2014/6/4NokiaSolutionsandNetworks
RX out of order 1/1
RX out of order Fault ID and name
1911: EFaultId_FrRxOutOfOrder
Usedinproducts
FlexiBTS
Detectingunit
FRx/LTX
Source
LTX, RX1-n
Meaning
TheRFModuleRXRFsynthesizerisnotlocked.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
LED display
Calls are not possible through the affected cell(s) (7653 CELL FAULTY). The problems might occur in the calls through the affected cell(s) (7654 CELL OPERATION DEGRADED). 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Blinking red (7654), Stable red (7653). 1. Block/unblock the RF Module.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d8058097a443
©2014/6/4NokiaSolutionsandNetworks
RF BB bus configuration error 1/1
RF BB bus configuration error Fault ID and name Usedinproducts Detectingunit
1905: EFaultId_FrRfBbBusConfigError FlexiBTS FRx/LTX
Source
LTX, TX1-n, RX1-n
Meaning
The RF Module baseband bus is configured incorrectly.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
Calls are not possible through the affected cell(s) (7653 CELL FAULTY). There might be problems in calls through the affected cell(s) (7654 CELL OPERATION DEGRADED). No impact on system (7652 BASE STATION NOTIFICATION) 7652 BASE STATION NOTIFICATION
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Stable red (all Antenna Lines of the RF module are faulty); Blinking red (not all Antenna Lines of the RF module are faulty) 1. Block/unblock the RF Module.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
Baseband Bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d8058097a3f9
©2014/6/4NokiaSolutionsandNetworks
RF Module file not found 1/1
RF Module file not foun d Fault ID and name
1902: E FaultId_FrFileNotFound
Usedinproducts
FlexiBTS
Detectingunit
FRx/LTX
Source
LTX
Meaning
The RF Module SW detected that a non-critical configuration file is missing.
State
Start
Unit status
Degraded
Unit status attributes Effect
The RF Module is configured using defaults and the performance is not as expected.
Reported alarms
7654CELLOPERATIONDEGRADED
LEDdisplay
Blinkingred 1.Block/unblock the RF Module.
Instructions 2.If that does not help, replace the alarming RF Module. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d8058097a3f7
©2014/6/4NokiaSolutionsandNetworks
RF Module critical file not found 1/1
RF Module critical file not found Fault ID and name Usedinproducts Detectingunit
1901: E FaultId_FrCriticalFileNotFound FlexiBTS FRx/LTX
Source
LTX
Meaning
A critical configuration file is missing from the RF Module.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LEDdisplay
The calls are not possible through the affected cell(s). 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Stablered
Instructions
ReplacethealarmingRFModule.
Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d8058097a3f6
©2014/6/4NokiaSolutionsandNetworks
RF Module configuring failed 1/1
RF Module configuring failed Fault ID and name Usedinproducts Detectingunit
1900: E FaultId_FrConfiguringFailed FlexiBTS FRx/LTX
Source
LTX
Meaning
The RF Module configuration failed because of a HW or SW fault.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LEDdisplay
The calls are not possible through the affected cell(s). 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Stablered
Instructions
ReplacethealarmingRFModule.
Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d8058097a3f5
©2014/6/4NokiaSolutionsandNetworks
Configuration file corrupted 1/1
Configuration file corrupted Fault ID and name Usedinproducts Detectingunit
1924: EFaultId_FrConfigurationFileCorrupted FlexiBTS FRx/LTX
Source
LTX/TX1-n/RX1-n
Meaning
The RF Module SW detected conflicting or corrupted configuration data.
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Effect
The default configuration is used and the cell TX and/or RX performance is degraded. There can be problems in the calls through the affected cell(s).
Reported alarms
7654CELLOPERATIONDEGRADED
LEDdisplay
Blinkingred 1. Block/unblock the RF Module
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d8058097f55f
©2014/6/4NokiaSolutionsandNetworks
Unit unidentified 1/1
Unit unidentified Fault ID and name Usedinproducts Detectingunit
1923: EFaultId_FrUnitUnidentified FlexiBTS FRx/LTX
Source
LTX
Meaning
The permanent memory in the module is corrupted and the module product code or serial number is missing, or the module product code is unknown.
State
Start
Unit status
Degraded
Unit status attributes
Effect
The RF Module configuration might fail and cause another fault, and there can be problems in the calls through the affected cell(s).
Reported alarms
7654CELLOPERATIONDEGRADED
LEDdisplay
Blinkingred 1. Block/unblock the RF Module.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d8058097f55e
©2014/6/4NokiaSolutionsandNetworks
Transmission quality deteriorated 1/1
Transmission quality deteriorated Fault ID and name Usedinproducts Detectingunit
1921: EFaultId_FrTransmissionQualityDetoriated FlexiBTS FRx/LTX
Source
TX1-n
Meaning
TheTXsignaladjustmentfails.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
There can be problems in the calls through the affected cell(s).
Reported alarms
7654CELLOPERATIONDEGRADED
LEDdisplay
Blinkingred 1. Block/unblock the RF Module.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d8058097f55d
©2014/6/4NokiaSolutionsandNetworks
RF Module out of order 1/1
RF Module out o f ord er Fault ID and name
1912:E FaultId_FrOutOfOrder
Usedinproducts
FlexiBTS
Detectingunit
FRx/LTX
Source
LTX
Meaning
The RF Module is out of order because of a software or hardware fault.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
Reported alarms
LEDdisplay
The TX/RX paths of the RF Module are out of order and phone calls through the affected cell(s) are not possible. 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Stablered 1. Block/unblock the RF Module.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d8058097f55c
©2014/6/4NokiaSolutionsandNetworks
RF BB energy too high 1/1
RF BB ene rgy to o high Fault ID and name Usedinproducts Detectingunit
1909: EFaultId_FrBbEnergyTooHigh FlexiBTS FRx/LTX
Source
TX1-n
Meaning
TheTXfeedbacksignalpoweristoohigh.
State
Start Cancel /
Unit status
Working
Unit status attributes
Effect
The TX output power might be too high or low, and there might be problems in the calls through the affected cell(s).
Reported alarms LED display
N/A 1. Block/unblock the RF Module.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
Related information
Fault view
Id:0900d8058097f4e8
©2014/6/4NokiaSolutionsandNetworks
RF BB bus connection transmission error 1/1
RF BB bus connection transmission error Fault ID and name Usedinproducts Detectingunit
1906: E FaultId_FrRfBbBusConnTransError FlexiBTS FRx/LTX
Source
LTX TX1-n /
Meaning
There is an error in the baseband oroptical bus.
State
Start Cancel /
Unit status
Degraded
Unit status attributes
Effect
Reported alarms
LEDdisplay
There can be problems in the phone calls through the affected cell(s) or calls can be impossible. 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Blinkingred 1. Block/unblock the RF Module.
Instructions
2. (RF sharing case only) Check that all RP3-01 fiber links and SFP transceivers between system module and radio module are properly connected and working. Replace broken fiber link if needed. 3. If that does not help, replace the alarming RF Module.
Related faults
Baseband Bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d8058097f4e3
©2014/6/4NokiaSolutionsandNetworks
RF BB bus synchronization error 1/1
RF BB bus synchronization error Fault ID and name
1904: E FaultId_FrRfBbBusSynchError
Usedinproducts
FlexiBTS,LTE
Detectingunit
FRxLTX /
Source
LTX, TX1-n, RX1-n
Meaning
The baseband bus between the System Module and RF Module is out of synchronization.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes
Effect
Calls are not possible through the affected cell(s) (7653 CELL FAULTY). There might be problems in the calls through the affected cell(s) (7654 CELL OPERATION DEGRADED). No impact on system (7652 BASE STATION NOTIFICATION) 7652 BASE STATION NOTIFICATION
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Stable red (all Antenna Lines of the RF module are faulty); Blinking red (not all Antenna Lines of the RF module are faulty) 1. Check the cables between the System Module and RF Module. 2. Block/unblock the RF Module.
Instructions 3. If that does not help, block/unblock the site. 4. If that does not help, replace the alarming RF Module. Related faults
Baseband Bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d8058097f4e2
©2014/6/4NokiaSolutionsandNetworks
Post test failed 1/1
Post test failed Fault ID and name Usedinproducts Detectingunit
1925: EFaultId_FrPostTestFailed FlexiBTS FRx/LTX
Source
LTX
Meaning
An RF Module power-on self-test failed at start-up.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
The cell TX and/or RX performance may be degraded because the failure or calls are not possible through the affected cell(s).
Reportedalarms
7653CELLFAULTY
LEDdisplay
Stablered 1. Block/unblock the RF Module.
Instructions 2. If that does not help, replace the alarming RF Module. Related faults
RF Module failure 3010: EFaultId_RfModuleFailure
Related information
Fault view
Id:0900d805809802dc
©2014/6/4NokiaSolutionsandNetworks
IP address conflict 1/1
IP address conflict Fault ID and name
4144: EFaultId_IpAddressConflict
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM,FCT
Source
FCM, FCT
Meaning
RF module cannot be detected due to IP address conflict between RP3-01 nodes.
State
Start Cancel /
Unit status
Working
Unit status attributes
Effect
IP address conflict has been reported between RP3-01 nodes. When there is the IP address conflict, the conflicting (later identified) RP3-01 node is not detected and thus it is not seen on the Site Manager view.
Reported alarms
7652BASESTATIONNOTIFICATION
LED display
Instructions
N/A Update compatible SW for all conflicting RP3-01 nodes (check the SW versions to see the active SW version and update the active SW version), unless it is automatically updated by NetAct. Note that in case of chained radio modules, the SW update in this particular case can only be done one-by-one along the RF chain. In case the IP conflict situation is not solved, check the conflicting RP3-01 node on the site and ensure the SW update procedure has been properly executed.
Related faults
Related information
Fault view
Id:0900d8058098e9ef
©2014/6/4NokiaSolutionsandNetworks
Synchronization master missing 1/1
Synchronization master missing FaultIDa nd n ame Usedinproducts Detectingunit
4114:E FaultId_SynchronizationMasterMissingAl LTE FCM
Source
FSM
Meaning
Synchronization is lost when the System Module is working as a synchronization slave System Module. This indicates usually that a synchronization master System Module has been reset.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect Reportedalarms LEDdisplay
The SystemModule isoutof order and theBTSis out of order. 7650BASESTATIONFAULTY Stablered
Instructions
1. Wait for the startup to be completed if a synchronization master system module has been reset. 2. If there is 1858: EFaultId_FaultyFcmConfigurationAl after synchronization slave's recovery reset then check the RP3-01 cable between the synchronization master and synchronization slave system modules. 3. Check alarms in the synchronization master System Module and act accordingly. 4. Reset the synchronization master system module.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d80580a5702b
©2014/6/4NokiaSolutionsandNetworks
Cell configuration data distribution failed 1/1
Cell configuration data distribution failed Fault ID and name
6253:E FaultId_CellSetupFailed
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM,FCT
Source
LCR
Meaning
BTS raises this fault if it experiences a problem in internal configuration data distribution (cell setup) to C-Plane and U-Plane SW components.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect Reportedalarms LED display Instructions
Cellisdisabled 7653CELLFAULTY N/A Block/unblockBTS
Related faults
Related information
Fault view
Id:0900d8058099e45e
©2014/6/4NokiaSolutionsandNetworks
DC voltage administratively disabled 1/1
DC voltage administratively disabled Fault ID and name
4141: E FaultId_DcVoltageAdministrativelyDisabledAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM,FCT
Source
AntennaLine,ALD
Meaning
Feeding voltage is disabled for selected Antenna Line.
State
Start Cancel /
Unitstatus
Outoforder;Working
Unit status attributes
Out of order (ALD) Working (Antenna Line)
Effect
DCvoltageisdisabled onreportingAntennaLine. 7652 BASE STATION NOTIFICATION
Reported alarms
7654 CELL OPERATION DEGRADED 7655 CELL NOTIFICATION
LEDdisplay Instructions
Stablegreen To revert changes, DC Voltage should be enabled for reporting Antenna Line.
Related faults
Related information
Fault view
Id:0900d8058099e6cf
©2014/6/4NokiaSolutionsandNetworks
Cell reconfiguration data distribution failed 1/1
Cell reconfiguration data distribution failed Fault ID and name
6257: EFaultId_CellReconfigurationFailed
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM,FCT
Source
LCR
Meaning
BTS raises this fault if it experiences a problem in internal configuration data distribution (cell setup) to C-Plane and U-Plane SW components.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect Reportedalarms LED display Instructions
Cellisdisabled 7653CELLFAULTY N/A Block/unblockBTS
Related faults
Related information
Fault view
Id:0900d8058099e64b
©2014/6/4NokiaSolutionsandNetworks
PPS reference clock missing in startup 1/1
PPS reference clock missing in startup Fault ID and name
4153:EFaultId_PpsRefClcMissInStrtAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
FCM/FCT
Meaning
Phase synchronization has been commissioned at the btsSyncMode, but PPS reference clock has not become available during timeout, that is, waited for during startup.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
Startup is continued without reference clock but BTS is not directed to OnAir.
Reported alarms
7651BASESTATIONOPERATIONDEGRADED
LEDdisplay
Blinkingred 1. Check the GPS receiver installation.
Instructions
2. Check the GPS receiver status. 3. Check the connection between the GPS receiver and FSM.
Related faults
Related information
Fault view
Id:0900d80580a46bed
©2014/6/4NokiaSolutionsandNetworks
Summing not enabled for message type 1/1
Summing not enabled for message type FaultI Da ndn ame Usedinproducts Detectingunit
2059:EFaultId_MuksuSummingNotEnabledAl FlexiBTS FCM,FCT
Source
FCM, FCT
Meaning
Summing checks headers of the messages to be summed. If the header is not any of the allowed types, no summing is performed and an empty message is sent instead.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
The BTS operation is degraded because some of the BTS resources are not available.
Reported alarms
7651BASESTATIONOPERATIONDEGRADED
LEDdisplay
BlinkingRed(7651) 1. Block/unblock the BTS.
Instructions
2. Check log for line code violation (LCV) errors related to optical links. 3. Verify SFP (small form-factor pluggable transceiver) and fiber conditions.
Related faults
Baseband Bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d805809b48c3
©2014/6/4NokiaSolutionsandNetworks
Transmission rule collision in Muksu 1/1
Transmission rule collision in Muksu Fault ID and name Usedinproducts Detectingunit
2060: EFaultId_MuksuTransmissionRuleCollisionAI FlexiBTS FCM,FCT
Source
FCM, FCT
Meaning
Transmitter detected an RP3 message from a summing coincident with a transmission rule.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
The BTS operation is degraded because some of the BTS resources are not available.
Reported alarms
7651BASESTATIONOPERATIONDEGRADED
LEDdisplay
BlinkingRed(7651) 1. Block/unblock BTS.
Instructions 2. Check configuration. Related faults
Baseband Bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d805809b4986
©2014/6/4NokiaSolutionsandNetworks
Overload collision in transmitter 1/1
Overload collision in transmitter Fault IDa nd name Usedinproducts Detectingunit
2061:E FaultId_MuksuOverloadCollisionAl FlexiBTS FCM,FCT
Source
FCM, FCT
Meaning
Transmitter detected more data coming from a summing than the current link rate can support.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
The BTS operation is degraded, because some of the BTS resources are not available.
Reported alarms
7651BASESTATIONOPERATIONDEGRADED
LEDdisplay
BlinkingRed(7651) 1. Block/unblock BTS.
Instructions 2. Check baseband bus configuration related to RP3 link speeds. Related faults
Baseband Bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d805809b4987
©2014/6/4NokiaSolutionsandNetworks
BTS reference clock missing 1/2
BTS reference clock missing Fault IDa nd name
3080:E FaultId_BtsReferenceClockMissing
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
FSM
Meaning
This BTS synchronization fault indicates that the BTS (System Module) does not receive a synchronization reference signal suitable for the configured synchronization mode (either frequency or phase sync mode). This group fault indicates both the detailed fault reason (either PPS reference missing (1898), 2M external reference missing (1899) or Transmission clock missing (1816)) and the severity depending on the availability of the other configured synchronization sources. Minor Severity: This alarm is raised with this severity when there is another synchronization reference signal available which can be used for the configured eNB synchronization mode. The BTS still works properly. This alarm is cancelled when the synchronization reference signal is available again. Major Severity: This alarm is raised with this severity when no other synchronization reference signal is available according to the used synchronization mode. The BTS is in holdover mode. - This alarm indicates the missing synchronization signal, when one synchronization reference signal is configured only. - This alarm indicates the highest prioritized synchronization source failing at this time when more than one synchronization reference signal is configured. (Note: Alarm indication might result from another failing sync source that has lower priority). This alarm is cancelled when any synchronization reference signal is available again.
State
Start Cancel /
Unit status
N/A
Unit status attributes
Effect
Reported alarms
LED display
Alarms with minor severity are reported within 7652 BASE STATION NOTIFICATION. The fault situation does not affect the BTS air interface stability and BTS is still fully operational. Alarms with major severity are reported within 7651 BASE STATION OPERATION DEGRADED alarm. The fault situation does not affect directly the BTS air interface stability. The accuracy starts to drift slowly for frequency synchronization mode related features. Within that time the BTS works properly but the network performance might start to degrade gradually. It might take several weeks before the BTS operations start to be affected. Performance of TDD system function and FDD phase synchronization related features degrades faster (for example, LTE426 SIB8 CDMA2000 Timing). 7651 BASE STATION OPERATION DEGRADED 7652 BASE STATION NOTIFICATION N/A The maximum number of synchronization reference signals that can be used for synchronization depends on the configured synchronization mode. In case of phase synchronization mode, this fault is raised only after the eNB start-up has been finished successfully. (During start-up, refer to alarm 4153, PPS reference clock missing in start-up). The related faults triggering this fault, for example, because of missing reference signal at either 1pps, 2.048 MHz or transport interface differs in hysteresis; this could lead to overlapping; (hysteresis values are specified in start/cancel field of related fault). Depending on the installed and commissioned synchronization source(s), see the commissioned synchronization option below and perform the steps in the listed order until the BTS fault indication disappears. GPS receiver (PPS source): 1. If there is a GPS receiver commissioned at the BTS site, note the following: If the GPS receiver is not locked to any satellite, it turns off the PPS signal which is normally delivered to the BTS (Sync In interface). The most common reason is that the GPS receiver does not see any satellites because of poor antenna installation (poor sky visibility). For this, the only ermanent cure is to chan e the GPS antenna location. One indication of a fairl
oor sk
BTS reference clock missing 2/2
Instructions
External2.048MHzsignal: 1. If there is an external 2.048 MHz signal source commissioned at the BTS site, check the BTS faults of that device and act accordingly. If this does not help, check the cables. Note that because the device type is not known, detailed instructions cannot be given - refer to the appropriate user manual of the device for further actions. 2. There might be a malfunction in the BTS. Perform a BTS site reset. FTM reference (TDM, SyncE or ToP as source): 1. If there is an integrated transmission unit (FTM) commissioned at the BTS site, note the following: The FTM unit operates so that if it is not locked to a synchronization source, it turns off the clock reference signal which is normally delivered to the BTS master clock. The synchronization source of the FTM (set by the FTM synchronization priority setting) might be missing, causing the FTM's internal clock to drop to holdover mode. In this case, the fault in the transmission NETWORK must be corrected (FTM itself might be working fine). 2. Check the alarms of the FTM unit and act accordingly. 3. Check the synchronization settings of the FTM unit. 4. There might be a malfunction in the BTS. Perform a BTS site reset. 5. There might be an equipment failure in the FTM unit. Check the operation and replace the unit, if needed. Note: Normally, the reason is not an equipment failure, but there might be connection failures in the transmission or packet network, causing the FTM clock to drop to holdover mode. Especially the BTS fault indication activity (frequent BTS fault indication activations/cancels instead of a stable BTS fault indication state) points to the instability of the transmission network, not to a failure in the unit. If the previous steps do not help, there might be an equipment failure in the System Module. Check the operation and if performing a BTS site reset does not help, replace the System Module. Transmission clock missing 1816: EFaultId_Trans_Clk_MsgAl
Related faults
PPS reference missing 1898: EFaultId_PpsRefMissAl 2M external reference missing 1899: EFaultId_2MExtRefMissAl
Related information
Fault view
Id:0900d80580a46776
©2014/6/4NokiaSolutionsandNetworks
Loss of primary Opt IF 1/1
Loss of primary Opt IF Fault ID and name
4161: EFaultId_LossOfPrimaryOptIfAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM/FCT
Source
OptIF
Meaning
FSM notices that a primary optical link connection to the Radio Module has been lost and the radio has been detected only via the secondary (capacity) optical link.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
LEDdisplay
ThisfaultpreventstheimpactedRFunitfromworking. 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED Stablered
Instructions
Optical cabling from the System Module to the Radio Module needs to be corrected.
Related faults
Failure in optical RP3 interface 3030: EFaultId_FailureInOptical_Rp3Interface
Related information
Fault view
Id:0900d805809ee645
©2014/6/4NokiaSolutionsandNetworks
RP3 routing collisions are detected on FR module 1/1
RP3 routing collisions are detected on FR module Fault ID and name
1958: EFaultId_Rp3CollisionOnFr
Usedinproducts
FlexiBTS,LTE
Detecting unit
FR
Source
FR
Meaning
FR module detected permanent RP3 routing collisions either in downlink (TX), or in uplink (RX) transmission direction.
State
Start Cancel /
Unit status
Working
Unit status attributes
Effect
Flexi BTS unit in question is transmitting or receiving data with degraded performance. Fault does not trigger special action on BTS.
Reported alarms
7652BASESTATIONNOTIFICATION
LED display
Instructions
N/A 1. Check BTS connections and commissioning settings. 2. Block/unblock the BTS (using the local BTS Site Manager connection if a remote connection is not possible).
Related faults
Related information
Fault view
Id:0900d80580a38dbb
©2014/6/4NokiaSolutionsandNetworks
RS485 IUANT port failure 1/1
RS485 IUANT port failu re Fault ID and name Usedinproducts Detectingunit
4069:E FaultId_Rs485PowerFailureAl FlexiBTS FlexiFilter,FR
Source
Antenna line
Meaning
Radio Module or Filter (all others) has detected overcurrent on RS485 IUANT port. Some antenna line device is causing overload. Depending on HW implementation antenna line devices powered by the RS485 IUANT and/or powered by antenna line are out of order. Overcurrent was detected on RS485 IUANT port. Some antenna line device is causing overload or shortcut exists on port. Antenna line devices powered by the rs485 IUANT port are out of order.
State
Start
Unit status
Degraded
Unit status attributes Effect
The RS485 i/f is not operating correctly. The cell capacity decreases.
Reported alarms
7654CELLOPERATIONDEGRADED
LED display
Blinking red (RF working, Antenna Line faulty) 1. Check the RS485 IUANT i/f and antenna line devices. Fix or replace the faulty parts/devices.
Instructions 2. Alarm is canceled only at RF Module reset or the BTS reset. Related faults
Related information
Fault view
Id:0900d80580a0b489
©2014/6/4NokiaSolutionsandNetworks
Base Station configuration alignment lost alarm 1/1
Base Station configuration alignment lost alarm Fault ID and name Usedinproducts Detectingunit
4171: EFaultId_BaseStationConfigurationAlignmentLostAl LTE FCM,FCT
Source
FCM(FSMr2),FCT(FSMr3)
Meaning
The configuration data alignment between BTS and NetAct is lost. No Ack or any nackReason from OMS for Configuration Change Notifications (CCN) or buffered CCNs is lost because too long BTS O&M interface connection break.
State
Start Cancel /
Unit status
Working
Unit status attributes
Working: There is only misalignment in NetAct database and BTS is working normally.
Effect
TheBTScontinuesworkingnormallywithallcells.
Reported alarms
7652BASESTATIONNOTIFICATION
LED display Instructions
N/A UploadBTSconfigurationfromNetAct.
Related faults
Related information
Fault view
Id:0900d80580a38dc7
©2014/6/4NokiaSolutionsandNetworks
RF loss of secondary optical interface 1/2
RF loss of secondary optical interface Fault ID and name Usedinproducts Detectingunit
1930: E FaultId_FRLossOfSecondaryOptIf LTE FRx/LTX
Source
FR
Meaning
Secondary optical link between the System Module and RF Module is lost.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Calls through the affected cell(s) are not possible 7652 BASE STATION NOTIFICATION
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LEDdisplay
Stablered Instructions are divided into three sections. Execute steps from section chosen based on best knowledge and common sense to minimize the cost and time effort. Section A: Check on system module side: 1. Check if connector seal is properly mounted and firmly in place. 2. Check if the SFP (Small Form Factor Pluggable) is properly connected/mounted in the System Module. If SFP connection/mounting is not correct readjust the connection/mounting. 3. Check if the LED indicates the faulty SFP (connected to System Module). Replace the SFP if it is faulty. 4. Check if the optical cable is properly connected/mounted in the SFP. 5. Clean the optical connectors that are connected to SFP. Reset RF HW unit by block/unblock procedures and check if this solves the problem.
Instructions
Section B: Check on radio module side: 1. Check if connector seal is properly mounted and firmly in place. 2. Check if the SFP (Small Form Factor Pluggable) is properly connected/mounted in the RF module. If SFP connection/mounting is not correct readjust the connection/mounting. 3. Check if the optical cable is properly connected/mounted in the SFP. 4. Clean the optical connectors at RF module end. Reset RF HW unit by block/unblock procedures and check if this solves the problem. Section C: Check of optical connection: 1. Check if optical cables are not over bend. If yes then replace the optical cable since over bending the optical fiber cables damages the cables and can detach or damage the connectors. 2. OPTIONAL: Test the fiber cable (f.ex. measure the optical attenuation) from System Module end. Please check measuring equipment documentation for instruction details. 3. OPTIONAL: Test the fiber cable (f.ex. measure the optical attenuation) from RF Module end. Please check measuring equipment documentation for instruction details. If alarm is still observed after executing steps from sections: A,B,C replace the RF module.
RF loss of secondary optical interface 2/2
Related faults
Related information
Fault view
Id:0900d80580a5dc7a
©2014/6/4NokiaSolutionsandNetworks
Message routing problem in receiver (RX) 1/1
Message routing problem in receiver (RX) Fault ID and name Usedinproducts Detectingunit
2058: E FaultId_MuksuMsgRoutingFailedAl FlexiBTS FCM,FCT
Source
FSP, OptIF
Meaning
If a message does not get routed an interrupt is generated. Considered normal when Faradays are starting up and RP3 sync done.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
The BTS operation is degraded because some of the BTS resources are not available. 7650 BASE STATION FAULTY
Reported alarms
7651 BASE STATION OPERATION DEGRADED 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Stable Red (7650), Blinking Red (7651), Stable Red (7653, 7654) If RF is the source:
Instructions
1. 2. 3. 4. 5.
Check antenna mapping to the local cells in the commissioning file. Check the cables between the System Module and RF Module. RF block/unblock BTS reset Replace the alarming module.
If FSP is the source: System Module reset should be performed. Related faults
Baseband Bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d80580a1f727
©2014/6/4NokiaSolutionsandNetworks
BB bus message in the wrong slot 1/1
BB bus message in the wrong slot Fault ID and name Usedinproducts Detectingunit
2057: EFaultId_MuksuMsgInWrongSlotAl FlexiBTS FCM,FCT
Source
FSP, OptIF
Meaning
Baseband bus message multiplexing slot for the message is not possible to be fulfilled.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
The BTS operation is degraded because some of the BTS resources are not available. 7650 BASE STATION FAULTY
Reported alarms
7651 BASE STATION OPERATION DEGRADED 7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Stable Red (7650), Blinking Red (7651), Stable Red (7653, 7654) If RF is the source:
Instructions
1. 2. 3. 4. 5.
Check antenna mapping to the local cells in the commissioning file. Check the cables between the System Module and RF Module. RF block/unblock BTS reset Replace the alarming module.
If FSP is the source: System Module reset should be performed. Related faults
Baseband Bus failure 3020: EFaultId_BaseBandBusFailure
Related information
Fault view
Id:0900d80580a1f726
©2014/6/4NokiaSolutionsandNetworks
High memory consumption 1/1
High memory consumption Fault ID and name
6502:EFaultId_HighMemoryConsumptionAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSM
Source
FCM/FCT, FSP
Meaning
Physical memory supervision detects that usage of memory has exceeded 90%(FCM/FCT)/ 98%(FSP).
State
Start Cancel /
Unit status
Working
Unit status attributes Effect
Highmemoryusage(memoryoutagerisk).
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Instructions
Stablegreen Source: - FCM/FCT: Perform eNB reset. - FSP: Change cell configuration to decrease call processing load.
Related faults
Related information
Fault view
Id:0900d80580a2155a
©2014/6/4NokiaSolutionsandNetworks
Antenna line device missing software 1/1
An ten na li ne devi ce mi ss in g so ft ware FaultIDa ndn ame
1848:E FaultId_WorkingSoftwareMissingAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
MHA,TILT
Source
MHA, TILT
Meaning
TheunitisinDownloadModeState.
State
Start Cancel /
Unit status
Degraded
Unit status attributes Effect
Reported alarms
LED display Instructions
Thedeviceisoutofuse. 7652 BASE STATION NOTIFICATION 7654 CELL OPERATION DEGRADED N/A 1. Replace the antenna line device.
Related faults
Related information
Fault view
Id:0900d80580a2201f
©2014/6/4NokiaSolutionsandNetworks
Critical BER detected on the optical connection to Radio Module 1/1
Critical BER detected on the optical connection to Radio Module Fault ID and name Usedinproducts Detectingunit
1956:E FaultId_CritBerOnRp3 LTE FRxLTX /
Source
FR
Meaning
Abnormally high bit error rate has been detected on the optical link to radio module which results in permanent baseband processing failure. I/Q data stream cannot be successfully processed by FRM due to the burst of consecutive LCV errors.
State
Start
Unitstatus
Outoforder
Unit status attributes Effect
Calls and data transmissions are not possible through the affected cell(s).
Reported alarms LEDdisplay
Instructions
Blinkingred Note! Perform the steps below in the listed order until the fault disappears. 1. Check the optical connection between system module and FR module. Check SFP module(s) and/or readjust optical connectors and verify operation of any devices in the optical network between FSM and FRM, if such devices are in use. 2. Block/unblock the FR module. 3. If the problem still exists, reset the site by blocking/unblocking the BTS. 4. If that does not help, replace the SFP module(s) in which the malfunctioning optical connection is terminated and/or replace the fiber.
Related faults
Related information
Fault view
Id:0900d80580a2201c
©2014/6/4NokiaSolutionsandNetworks
Antenna line switched off 1/1
An ten na li ne s wit ch ed o ff Fault IDa nd name
1957:E FaultId_AntennaLineSwitchedOffAl
Usedinproducts
FlexiBTS,LTE
Detecting unit
FR
Source
Antenna line
Meaning
Antenna line has been disabled to protect HW, that is because of high reflection conditions.
State
Start
Unitstatus
Outoforder
Unit status attributes
Effect
The cell is disabled. Downlink signal transmission on the given antenna line is disabled and corresponding FR transmitter is unusable, hence overall FR state is affected. 7652 BASE STATION NOTIFICATION
Reported alarms
7653 CELL FAULTY 7654 CELL OPERATION DEGRADED
LED display
Stable redmodule (all antenna lines of the RF module are faulty); Blinking red (not all antenna lines of the RF are faulty)
Instructions
1. VSWR measured at RF (transmitter) exceeds values acceptable by RF module. 2. Please check impedance matching of Antenna Line System (replace elements that cause mismatch). 3. In order to check if above mentioned steps solved the problem please block/unblock RF module. * Forcing RF HW to work under such conditions might results in RF HW permament damage
Related faults
Related information
Fault view
Id:0900d80580a4931f
©2014/6/4NokiaSolutionsandNetworks
Neighbor cell ambiguity detected 1/1
Neighbor cell ambiguity detected Fault ID and name
6274: E FaultId_NeighborCellAmbiguityDetected
Usedinproducts
FlexiBTS,LTE
Detectingunit
FSP
Source
LCR
Meaning
A handover target cell cannot be uniquely selected because several candidates are available for a certain PCI value and carrier frequency.
State
Transient
Unit status
Working
Unit status attributes Effect
No handover can be performed to cells with the affected PCI and frequency.
Reportedalarms
7655CELLNOTIFICATION
LEDdisplay
Stablegreen
Instructions
Add the LNREL object pointing to the correct neighbor to allow the handover or enable the UE-based ANR.
Related faults
Related information
Fault view
Id:0900d80580a33ef5
©2014/6/4NokiaSolutionsandNetworks
Error in file server during file download type 1/1
Error in file server during file download type Fault ID and name
27: EFaultId_FileServerAl
Used in products
Supreme, Optima, Optima IBBU, Optima Compact RF Extension, MetroSite, Triplemode, MetroSite 50, FlexiBTS
Detecting u nit
UltraSite, MetroSite, MetroSite 50, Triple-mode: W AM; FlexiBTS: FCM; UltraSite/EUBB: W AMA
Source
UltraSite, MetroSite, MetroSite 50, Triple-mode: WAM FlexiBTS: FCM UltraSite/EUBB: WAMA
Meaning
The BTS is unable to obtain a file from the file server (error in FTP open or FTP get). The file server is down, the file is missing, or the path is incorrect. A possible error in the DCN and Iub, or a user administration error (an invalid username or password, or the user does not have access rights for the files). included in fault name is a variable parameter identifying the type of file for which download failure has been reported.
State
Start Cancel /
Unit status
Working
Unit status attributes Effect
TheBTScontinuesitsoperationwiththeoldfile.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay
Instructions
Stablegreen 1.Check the file type according to the table below: - 1 - hwConfigurationFile 2 - configurationPlanFile 3 - logFile 4 - swFile 5 - licFile 6 - measurementFile 7 - rnwConfigurationPlanFile 11 - combinedSiteConfigurationPlanFile 12 - allConfigurationPlanFile 14 - testResultFile 15 - autoConfReport 17 - measurementPlanFile 18 - rnwMetadataFile 19 - topologyFile 22 - togglingParFile 23 - troubleShootingData 2. Retry the file update a few times. 3. Check the FTP account user settings. 4. Check the file and path names. 5. Check the administration log on the file server.
Related faults
Related information
Fault view
Id:0900d80580a3aedf
©2014/6/4NokiaSolutionsandNetworks
PLL status not locked 1/1
PLL status not locked Fault ID and name
4010: EFaultId_PLLStatusNotLockedAl
Usedinproducts
FlexiBTS,LTE
Detectingunit
FCM
Source
FSP
Meaning
BTS monitors the FSP PLL (Phase-Locked Loop) lock status and PLL locking fails.
State
Start Cancel /
Unitstatus
Outoforder
Unit status attributes Effect
Reported alarms
BTSisnotoperational orthecapacityisdegraded. 7650 BASE STATION FAULTY 7651 BASE STATION OPERATION DEGRADED
LED display
Blinking red (7651), Stable red (7650)
Instructions
1. Block/unblock the FSM. 2. If that does not help, replace the FSM.
Related faults
System Module failure 3000: EFaultId_SystemModuleFailure
Related information
Fault view
Id:0900d80580a4671f
©2014/6/4NokiaSolutionsandNetworks
BTS reset time increased 1/1
BTS reset time increased Fault ID and name
4091: EFaultId_BtsResetTimeIncreasedAl
Usedinproducts
FlexiBTS
Detectingunit
FSM
Source
FSM
Meaning
BTS has detected RF module power cycle failure and is trying to recover from the failure during BTS reset procedure. BTS reset will last longer due to additional actions performed by BTS to recover from faulty situation.
State
Start
Unit status
Working
Unit status attributes Effect
OngoingBTSresetwilllastlonger.
Reported alarms
7652BASESTATIONNOTIFICATION
LEDdisplay Instructions
Stablegreen None
Related faults
Related information
Fault view
Id:0900d80580a51bc0
©2014/6/4NokiaSolutionsandNetworks