floor within the installation complies with the requirements
8 mm and/or reinforcing bars positioned above one
of the applicable technical standards as described below.
another.
Load-bearing capacity of the floor
Special protective measures to prevent the formation of
According to EN 15512, DIN 15629 and instructions
corrosion are required with aggressive or magnesite-based
contained in EN 15635, installation areas for warehouse
floors.
facilities and equipment must be designed to bear the unladen weights and permissible payloads safely.
Floor tolerances
The levelness of the warehouse floor must as a minimum The permissible floor compression must be higher than
comply with the structural engineering tolerances as
the value specified for the shelving system. The person
defined in chapter “Floor”.
ordering and/or operating the pallet racks is responsible for ensuring that the floor is designed and built to bear
Floor sagging
the load of the uprights for the rack.
When installing pallet racks, sagging, in particular in the case of suspended floors, can have a significant influence
Here, the maximum surface load of the entire covered
on the correct functioning of storage facilities. For station-
surface and the point load of the forces introduced via
ary storage facilities, sagging, measured at the widest span,
the feet of the uprights must be taken into consideration.
must not exceed 0.75 x 1/500.
The field load is the sum of all shelf loads relative to a
field A
beam length, with the exception of stored goods placed directly on the floor. The sum of all shelf loads must not
field B
exceed the permissible field load. The posts load and the uprights load respectively result from the field loads applied from the right and left. Floor quality
A minimum concrete quality of C20/25 with corresponding corresponding reinforcement (EN 206-1) is assumed for the warehouse floor. The warehouse floor must be at least 20 cm thick and allow floor anchoring with expansion plugs; drilling depth: approx. 15 cm.