Method Statement for Installation of Diesel Generator Set
Method statement of Diesel Generator set.It will be vary with site condition & type of Generator
Blinding Concrete- Method Statement
Method
BOX CULVERTS-Method Statement
MethodFull description
Outline Construction Method Statement
Method Statement Outline, construction
Pekerjaan STP - Method Statement
Full description
Electrical Panels Method Statement
MS for Testing and commissioning of electrical panelFull description
Method of Statement Firefighting
Method of statement Fire FightingFull description
Construction Method Statement
ConstructionFull description
Method Statement (RC Slab)
Method statement (RC Slab)
Method Statement (RC Slab)
Method statement (RC Slab)Full description
pressure part method statement
Oil fired boiler method of statement
Method Statement Survey.
7.1 Prior to pre commissioning activity -
Check generator earthing should be proper earthed .
-
Check power and control cable termination.
-
Make general visual inspection on the engine and alternator. Check if there any breakage , crack , indentation , leakage or looseness.
-
Take our foreign material such as keys, tools, cleaning wool, paner etc.
-
Check the fuel level in the dark tank. Refil with fuel if it low .
-
Check engine oil level on the dip stick, Refill with fuel if it is low.
-
Look at the water level by opening the radiator tap. If it is inadequate add more water.
-
Inspect the radiator air outlet hood, Open if clogged and clear away all obstruction in front of air outlet .
-
Check air filter gauge . Clean or replace the air filter If necessary. necessary.
-
Keep the inlet opening open .
-
Make sure that the generating set can take easily air from environment.
-
Check battery connection ,Tight if found any loss .
-
Open the battery cap and check the liquid level in the cells .
-
Check circuit breaker outlet switch is in off position .
-
Make Sure that emergency pushbutton is not pressed .
-
Starting the generation will be performing by commissioning assistant .
×
Report "Method Statement Generator"
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
×
Sign In
Email
Password
Remember me
Forgot password?
Sign In
Our partners will collect data and use cookies for ad personalization and measurement.
Learn how we and our ad partner Google, collect and use data
.
Agree & close