IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM
1
GROUP 1 - OVERALL SYSTEMS
1.01
REGULATIONS & CERT.
1.02
DOCUMENTATION
1.03
GENERAL INFORMATION
1.03.1 1.03.2 1.03.3 1.03.4 1.03.5 1.03.6 1.03.7
Vessel Design/type Registration (Flag) Yard delivery Major modifications Classification Additional class notations Date of last 5-year class survey (SPS)
1.04.
PERFORMANCE & CAPABILITIES
1.04.1 1.04.2 1.04.3 1.04.4 1.04.5 1.04.6
Displacement at operating draft (t) Variable load-operation (t) Variable load-survival (t) Variable load transit (t) Max water depth (ft) Min water depth (ft)
1.04.7
Design temperature hull (0 C)
1.04.8 1.04.9
1.04.18 1.04.19 1.04.20 1.04.21 1.04.22 1.04.23 1.04.24 1.04.25
Design temperature equipment (0 C) Minimum operating temperature ( C) Design Criteria operation: Wind 1 hr sust. (kts) Wave height sign. (ft) Wave period (s) Surface current (kts) Max offset Max heave (d.a.) (ft) Max roll (d.a.) (deg) Max pitch (d.a.) (deg) Design Criteria Survival: Wind 1 hr. sust. (kts) Wave height sign. (ft) Wave period (s) Surface current (kts) Max offset (% of WD) Max heave (d.a.) (ft) Max roll (d.a.) (deg) Max pitch (d.a.) (deg)
1.05
MAINTENANCE SYSTEM
1.04.10 1.04.11 1.04.12 1.04.13 1.04.14 1.04.15 1.04.16 1.04.17
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Friede&Goldman/"ExD" DPS-3 Shanghai Waigaoqiao Shipbuilding Ltd. New building ABS A1 Column Stabilized Drilling Unit, DPS-3, New building
~52200 9000 9000 N/A 10,000 400 Air: 40℃ maximum, -10℃ minimum Water: 30℃ maximum, 0℃ minimum Air: 40℃ maximum, 0℃ minimum Water: 30℃ maximum, 0℃ minimum 0℃ 45 19.685 11.2 1.8 2~3% water depth 15 5~7 5~7 107 13.3 15.5 3.83 N/A 50 20 20
Page 1 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Databased system
2 2.01
TBA
GROUP 2 - MARINE SYSTEMS POWER SUPPLY & DISTRIBUTION
Type of system Number of generator sets Power rating each forward (kW) Power rating each aft (KW) 2.01.4 Total generated power (KW) 2.01.5 Main power voltage (V) 2.01.6 Main power frequency (Hz) 2.01.7 Approx. power consumption during normal drilling operations (KW) 2.01.9 Fuel consumption at service speed (mt/day) 2.01.10 Fuel consumption in operation (bbl/day) 2.01.11 Harbour generator (kW) 2.01.12 Emergency generator (KW)
Generator driven by diesel engine 8 N/A 5530 44240 11000 60 21964 199 150000 Emergency generator include Harbour fuction TBA
2.01.1 2.01.2 2.01.3
2.02
PROPULSION SYSTEM
2.02.1 2.02.2 2.02.3 2.02.4 2.02.5 2.02.6 2.02.7 2.02.8 2.02.9 2.02.10 2.02.11 2.02.12 2.02.13 2.02.14 2.02.15 2.02.16 2.02.17 2.02.19
Transit speed (knots) Main Propulsion: Number of: Power cons. each (kW) Thrust force each (Mt) Controllable pitch (Y/N) Azimuth Thrusters: Number of: Power cons. each (kW) Thrust force each (t) Controllable pitch (Y/N) Fixed/Retractible Tunnel Thrusters: Number of Power cons. each (kW) Thrust force each (Mt) Controllable pitch (Y/N) Total thrust available for DP (t)
2.03
MOORING SYSTEM :
2.03.1 2.03.2 2.03.3 2.03.4 2.03.5 2.03.6 2.03.7
No. of mooring lines Chain, wire or combined system No. of independent brake systems Central release of mooring lines Central release locations Automatic overspeed protection Permanent chaser system
TBD N/A N/A N/A N/A 8 4600 80 N Fixed N/A N/A N/A N/A 640 Harbour mooring only 4 chain N/A N/A N/A N/A N/A
Page 2 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 2.03.8 2.03.9
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Anchors type/weight (Mt) An alarm indicating tension in the anchor line exceeding specified levels (Y/N)
10 N/A
2.03.10 Automatic activation of anchor-winch deluge system during emergency release (Y/N)
2.04
DYNAMIC POSITIONING SYSTEM
2.04.1 2.04.2 2.04.3 2.04.4 2.04.5 2.04.6 2.04.7 2.04.8 2.04.9 2.04.10 2.04.11 2.04.12 2.04.13 2.04.14 2.04.15 2.04.16 2.04.17 2.04.18 2.04.19 2.04.20 2.04.21 2.04.22 2.04.23 2.04.24 2.04.25
System make / type Back-up system type IMO / NMD Consequence Class Position reference systems: - DGPS No.of / type - DGPS corrections No. of / type - Radio microwave No.of / type - Hydroacoustic No.of / type - Taut Wire No.of / type - El. riser angle indicator No.of / type - Other references No.of / type Failure condition: Maximum single failure Percentage loss of total thrust (%) Max condition at max single failure: - Wind (kts) - Current (kts) - Sign. Wave Height (ft)
2.05
ACOUSTIC POSITION CONTROL
2.05.1
System make/type
2.05.2 2.05.3 2.05.4 2.05.5 2.05.6 2.05.7 2.05.8 2.05.9
Positioning accuracy, % of slant range distance transducer-transponder Cap. different transponder signal types / channels Cap. different signals simultaneously No. of signals simultaneously on screen VDU monitor locations No. of transducers No. of transponders Tuning of transponders on new location
2.06
BALLAST SYSTEM
2.06.1 2.06.2
No. of separate pump rooms No. of ballast pumps
N/A
DP system Single DP control system DP- 3 Y 2 pcs/DP132(GPS/SBAS),DPS200(GPS/GLONASS) Y Position accuracy:≤1m 95% CEP,Velocity accuracy 0.1m/s 95% CEP(*) N/A N/A Y 2 pcs N/A N/A Y 1 pcs/seaflex (24v, <10w) DP Sensors wind, gryo,MRU one engine room or one switchboard room or one thruster room 25 45 1.8 18
ACOUSTIC narrow receiver beam +5° ,operating area below vessel ±100° , range dectection accruary 0.1m max at 20dB ,angle accuracy ≤ 0.21° at 20dB. TBA TBA TBA CCR,ECR 2 6(MPT 5pcs,SPT 1 pcs) N/A
8 8
Page 3 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 2.06.3 2.06.4 2.06.5 2.06.6 2.06.7 2.06.8 2.06.9
2.07
BILGE AND DRAIN SYSTEMS
2.07.1 2.07.2
Bilge water separator capacity (gph) At least one ballast pump is connected to the bilge system
2.07.3 2.07.4 2.07.5 2.07.6 2.07.7 2.07.8 2.07.9 2.07.10 2.07.11 2.07.12
One dedicated pump in each pontoon is connected to the emergency switchboard Closed drain system collecting to seperate tank connected to bilge system Drain from drill floor conn. to closed syst. (Y/N) Drain from set back conn. to closed syst. (Y/N) Drain from test unit conn. to closed syst. (Y/N) Drain from pipe rack conn. to closed syst. (Y/N) Drain from cement room conn. to closed syst. (Y/N) Drain from mud room conn. to closed syst. (Y/N) Drain from shaker room conn. to closed syst. (Y/N) Drain from sack store conn. to closed syst. (Y/N)
2.08 2.08.1 2.08.2 2.08.3 2.08.4 2.08.5 2.08.6 2.08.7 2.08.8 2.08.9
2.09 2.09.1 2.09.2 2.09.3 2.09.4 2.09.5
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Capacity each (GPh) Variable speed (Y/N) Stripping system Eductor capacity (gpm) Ballasting time, transit to operation (h) Deballasting time, operation to transit (h) Deballasting time, operation to survival (h)
79251.3 N Y 220 7 7 2
2642 Y Y Y Y Y Y Y Y Y Y Y
COOLING WATER SYSTEM No. of independent systems Sea water system: No. of pumps Total capacity (gpm) Variable speed operation (Y/N) Fresh water system: No. of pumps Total capacity (gpm) Variable speed operation (Y/N)
4 4 8800 N 3 5500 N
COMPRESSED AIR SYSTEM Starting air: No. of compressors Capacity each (cuftr) Pressure (psi) Design dew point temperature (deg C)
4 38m3/h&20m3/h (2&2) 3.00 N
Page 4 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 2.09.6 2.09.7 2.09.8 2.09.9 2.09.10 2.09.11 2.09.12
2.10
DECK CRANES & OVERHEAD CRANES
2.10.1 2.10.2 2.10.3 2.10.4
Deck Crane no 1: Location Type / Make Rating (tm)
2.10.5 2.10.6 2.10.7 2.10.8 2.10.9 2.10.10 2.10.11 2.10.12 2.10.13 2.10.14 2.10.15 2.10.16 2.10.17 2.10.18 2.10.19 2.10.20 2.10.21 2.10.22 2.10.23 2.10.24 2.10.25 2.10.26 2.10.27 2.10.28 2.10.29 2.10.30 2.10.31
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Service and Control air: No. of compressors Capacity each (CUFT/hr) Total capacity (CUFT/hr) Pressure (psi) Design dew point temperature (deg C) Provided with air dryers (Y/N)
3 49526 148578 1.45 -40 Y
Port TBD 80 tons/24.0 m radius
80 tons from 8.7 m to 24.0 m radius 32 tons from 8.7 m to 46.0 m radius 15 tons from 11.0 m to 51.0 m radius
Main hook SWL (t) Auxiliary hook SWL (t) Deck Crane no 2: Location Type / Make Rating (tm)
Starboard TBD 80 tons/24.0 m radius
80 tons from 8.7 m to 24.0 m radius 32 tons from 8.7 m to 46.0 m radius 15 tons from 11.0 m to 51.0 m radius
Main hook SWL (t) Auxiliary hook SWL (t) Deck Crane no 3: Location Type / Make Rating (tm) Main hook SWL (t) Auxiliary hook SWL (t) Knuckle Boom crane, Main Pipe Deck: Capacity SWL (t) Tubular handling capacity Max tubular length (ft) Max height (FT) Riser handling crane, Aft Deck: Capacity SWL (t) Tubular handling capacity Max riser length (ft) Max height (FT) Overhead crane, subsea equipment: Tree Assembly Crane & Trolley Capacity SWL (t) Max stack-up height (FT)
2.11
ENVIRONMENTAL AND PLATFORM DATA (E&P DATA)
2.11.1
Provisions for central monitoring of:
2.11.2
Wind speed and direction
N/A N/A N/A N/A N/A 15T 15T 14000mm 41200mm 40mT 0.1m/s 75 TBD 2x75T 32
2 pcs ultrasonic wind sensor II (40mA at 24VDC) and 1 pcs vane-anemometer wind sensor OMC-160 (60mA at 24VDC)
Page 5 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 2.11.3 2.11.4 2.11.5 2.11.6 2.11.7 2.11.8 2.11.9 2.11.10 2.11.11 2.11.12 2.11.13
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Wave height, period and direction Current speed and direction * Air temperature Air pressure Sea water temperature Vessel roll Vessel pitch Vessel heave Vessel heading Vessel draught Accoustic Doppler Current Profiler
2.12
COMMUNICATION SYSTEMS
2.12.1 2.12.2 2.12.3 2.12.4 2.12.5 2.12.6
Satellite Communication system No. of dedicated telephone lines for Operators offices on RigNet SatCom system No. of telefax lines on RigNet SatCom system No. of telefax machines for operator use No. of mobile phones for operator use Line for sync./async.data communication
2.12.7 2.12.8 2.12.9 2.12.10 2.12.11 2.12.12 2.12.13 2.12.14 2.12.15 2.12.16 2.12.17
No. of UHF transceivers (w/ headsets) No. of VHF transceivers communication between : Deck crane - deck Deck crane - drillfloor Drill floor - cement unit Drill floor - cellar deck Drill floor - derrick man (derrick & pump room) Drill floor - pipehandling pipe deck Drill floor- person in riding belt ("hand-free") PA system and telephone to all third party containers
3 3.01
GROUP 3 - DRILLING AND COMPLETION EQUIPMENT THE DRILLING DERRICK AND EQUIPMENT
3.01.1 3.01.2 3.01.3 3.01.4 3.01.5 3.01.6 3.01.7 3.01.8
Derrick rating (t) Hook SWL (t) Top Drive connected to Traveling block (Y/N) Racking capacity, 5 7/8" D.P. (FT) Racking capacity, 6 5/8" D.P. (FT) Racking capacity of 8" D.C. (ft) Racking capacity, 9 1/2" D.C. (FT) Racking capacity, marine riser jnt.
Y Y OMC-443 (9 to 30VDC,4 to 10mA) Setra 470 (100 to 240VDC, 70ma max) N/A MRU (12 to 30VDC, max 14.5W, IP66) MRU (12 to 30VDC, max 14.5W, IP66) MRU (12 to 30VDC, max 14.5W, IP66) Navigat X Mk.1 (115/230VAC normal, 24VDC emergency, 45w) IL-10 (0 to 0.4 MP ,accuracy 0.5%) N/A
Y At least 16pcs At least 3pcs About 200 telephones.Can use fax by Satellite 25 UHF handsets Satellite bandwidth can reach to 2Mbits/s Five. Each crane have one transceiver.The others are installed in radio room and central control room Three.Two in radio room and one in central control room Use UHF equipment.Crane will have speaker to broadcast Use UHF equipment. Use Auto telephone, talkback, PA/GA access panel or UHF equipment Use Auto telephone, talkback, PA/GA access panel or UHF equipment Use Auto telephone, talkback, PA/GA access panel or UHF equipment Use Auto telephone, talkback, PA/GA access panel or UHF equipment PA/GA Speaker,talkback or UHF hand-free equipmentt uniform interface like junction box installed nearby third party containers
907.2T 907.2T Y 108 stands 204 stands TBD 20 stands 99ea 13 5/8" -- 49x135' 9 5/8"--72x135' 2.44t/m2
3.01.9 Racking capacity, 13 5/8" Csg. OR 9 5/8 csg 3.01.11 Setback weight capacity (t)
Page 6 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 3.01.12 3.01.13 3.01.14 3.01.15 3.01.16 3.01.17
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Stabbing board for casing, adj. height Derrick racking height (ft) Overdrill, by 1m stick up cont. (ft) Stand length (ft) Powered sliding door in front of the V-door opening (Y/N) Company logo/ well no.to be installed in derrick
3.02
HOISTING EQUIPMENT
3.02.1 3.02.2
Max pull elevator (t) Passive and active compensation.
107'-8" 210ft TBD 46ft x 52ft Y Y
Y
Hoisting equipment in derrick , and elevators, acc.to API spec.8C PSL 1 or PSL 2 Max pull speed Safety device to prevent the travelling yoke : - Being run into the top 3.02.5 - Being run into the drillfloor 3.02.6 - Being run into the stabbing basket 3.02.7 3.02.8 Travelling block SWL (t) 3.02.9 No.of personnel winches covering cellar deck 3.02.10 No.of personnel winches covering drillfloor 3.02.11 Personnel winches in compliance with NPD §28 (ref. 1.01.1 /1/) 3.02.3 3.02.4
Y 240rpm 125rpm 125rpm 125rpm 907T 2 2
3.02.12 Workwinches on drillfloor: ea./ t 3.02.13 Workwinches on cellardeck: ea./ t 3.02.14 Two separate brakes,one automatic, on the work winches At Coinencement Date the drilling line shall be slipped and/or cut to provide zero ton3.02.15 mile 3.02.16 Enough drilling line wire onboard for complete change.
3.03
5T X 2 10T X 2 5T X 2 10T X 2 Y TBD Y
DRILLING INSTRUMENTATION
Drillers panel with following as a minimum: 3.03.1 Pump pressure gauge 3,03.2 Cement line press indicator 3.03.3 Weight indicator 3.03.4 Pump strokes counter/ total strokes 3.03.5 Tong torque indicator 3.03.6 Iron roughneck torque indicator 3.03.7 Rotary/top drive torque 3.03.8 Cathead torque 3.03.9 Rotary/top drive speed indicator 3.03.10 PVT system 3.03.11 Trip tank level indicator w/alarm
Y Y Y Y Y Y Y Y Y Y Y
Page 7 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Gain/loss indicator w/alarm Mud flow out Yoke position indicator Ton-milr recorder Riser tension ton-mile recorder Drilling parameters chart recorder Top drive control panel Drill string compensator panel Choke and Kill panel high accurracy pressure measurement on low and high 3.03.20 pressures 3.03.21 Back-up system with power black-out (Y/N) 3.03.12 3.03.13 3.03.14 3.03.15 3.03.16 3.03.17 3.03.18 3.03.19
3.04
TOP DRIVE SYSTEM
3.04.1 3.04.2 3.04.3 3.04.4 3.04.5 3.04.6 3.04.7 3.04.8 3.04.9 3.04.10 3.04.11 3.04.12 3.04.13 3.0414
Static load capacity (t) Power continuous (KW) Max. torque at 145 rpm (ftlbs) Max. torque make up (ftlbs) Max. rotating speed Inner diameter of swivel and through the TD (IN) Make up/break out wrench, capacity (ftlbs) Tiltable bails (deg) Independent rotation of bails/elevator (Y/N) Upper kelly cock-remote (psi) Lower kelly cock-manual (psi) Top drive system D.P.size range from/to (inch) All functions for the top drive remotely controlled from the driller`s control panel Access through the top of the top drive for wireline operation
3.05
ROTATION SYSTEM
3.05.1 3.05.2 3.05.3 3.05.4 3.05.5
Motor rating hydraulic motor High/low speed (Rpm) Opening diameter rotary (inch) Load rating (t) Independent(simultanously) operating of TD and rotary table (Y/N)
3.06
BULK SYSTEM
3.06.1 3.06.3 3.06.4 3.06.5 3.06.6 3.06.7 3.06.8 3.06.9 3.06.11 3.06.12
Barite capacity (CuFt) OR Bentonite capacity (CuFt) Cement capacity (CuFt) Barite transfer rate to surge tanks (tons/hr) Cement transfer to surge tank (tons/hr) Number of barite surge tanks Number of cement surge tanks Barite transfer to cement surge tank (tons/hr) Number of barite or bentonite storage tanks Number of cement storage tanks Accuracy of surge tank load cells (LB)
Y Y Y Y Y Y Y Y Y Y
907 857 94.500 ft.lb at 0-125 rpm TBD 240RPM TBD TBD TBD Y TBD TBD 3 1/2''-6 5/8'' Y TBD
210bar 20rpm/-60 1/2" - 49 1/2" 907 N
553M3 350M3 80t/h 40t/h 2 1 80t/h 11 5 <1t
Page 8 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM
TECHNICAL SPECIFICATION / DETAILS FOR RIG
3.06.13 Storage tank load cells (Y/N) 3.06.14 Direct barite to active pits 3.06.15 Supply hoses length (FT)
Y Y 60M
3.06.16 Possible to mix barite in hoppers while taking onboard bulk barite from supply vessel 3.06.17 Control panels and compressor hooked up to the emergency generator
Page 9 of 27
Y N
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM
3.07
CEMENTING SYSTEM
3.07.1 3.07.2 3.07.3 3.07.4 3.07.5 3.07.6 3.07.7 3.07.8 3.07.9 3.07.10 3.07.11 3.07.12 3.07.13 3.07.14 3.07.15 3.07.16 3.07.17 3.07.18 3.07.19 3.07.20 3.07.21 3.07.22
1 ea 80 cuft steady flow bin 1 ea hydraulic power pack 1 ea lap system 1 ea diesel fuel tank 2 ea air receiver 1 ea remote control 1 ea Compupac (data acquisition computer) 1 ea tool box/special tools for unit 1 ea emergency mixing equipment 1 ea acoustic bulkhead for cemt unit 1 ea acoustic bulkhead for hydraulic power pack 1 ea h-manifold, complete with valves 5ea Chiksan spool fro h-manifold to rig line 6 ea Chiksan 90O bend from h-manifold to rig line 1ea spare parts cupboard 1 ea adjustable work bench 1 ea las tank 2 ea remote radiator for cement unit 1 ea sink 1 ea tool cabinet w/hand tools HCS 25d cement unit w/2 ea cat 3406 diesel engine High pressure pump rating (bar)
3.08
RUNNING AND HANDLING OF TUBULARS
TECHNICAL SPECIFICATION / DETAILS FOR RIG Y N N Y N N Y Y Y N N Y Y Y N N Y N Y N Y 15,000PSI
Iron roughneck Drill floor manipulator arm Remote casing tong Pipe handling system from fingerboard on drill floor level Cat head (EZY torque) Block retraction system Kelly spinner 2 set handling equipment for all tool sizes Remote controll systems for transport of DP,DC Csg. etc. from pipedeck to the 3.08.9 drillfloor 3.08.10 Remote operated handling tools for all tubulars 3.08.1 3.08.2 3.08.3 3.08.4 3.08.5 3.08.6 3.08.7 3.08.8
3.09
DRILLING FLUID SYSTEM
3.09.1 3.09.2 3.09.3 3.09.4 3.09.5 3.09.6 3.09.7 3.09.8 3.09.9
Trip tank capacity (BBLS) Main mud tanks capacity (BBLS) Brine storage capacity in addition to mud cap. (BBLS) Mud cleaner, number Desander, number Centrifuge, number Variable speed centrifuge Degassers, number Degasser capacity full flow GPM
Y Y N Y Y Y Y Y Y Y
9.1M3 1104M3 723M3 2 3 3 N 2 1400GPM
Page 10 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Shakers, number Shakers, make/model Number of high pressure pumps Power output pr. pump (hP) Liner dimensions in HP mudpumps Liner stroke (in) Number of mixing hoppers Automitised mixing system stations Atmospheric degasser ventline diameter (inch) Atmospheric degasser liquid seal (FT) Atmospheric degasser liquid outlet (inch) Atmospheric degasser mud inlet (from choke manifold) (inch) Capacity of degasser tank (BBLS ) Mud buckets for relevant pipe size Suction/discharge module back-up for mud pumps available onboard (Y/N) The surface mud circulation system: 3.09.25 Withstand a drilling fluid temperature of (0C) 3.09.26 Able to handle a minimum mud flow of: (GPM) 3.09.27 Handle a drilling fluid density of: ( ppg ) 3.09.10 3.09.11 3.09.12 3.09.13 3.09.14 3.09.15 3.09.16 3.09.17 3.09.18 3.09.19 3.09.20 3.09.21 3.09.22 3.09.23 3.09.24
4 TBD TBD 125HP 5"~7 1/2" 14" 2 2 12" 6.1M 10" 5" 3.56M3 6" Y Y 2200GPM 21PPG
3.09.28
Centrifugal pumps have mechanical seal. (Flushing with anti leaking fluid is not acc.) 3.09.29 Treatment pit equipped with high pressure mud guns (100 bar) 3.09.30 Possible to mix in all hoppers without dust problems Mud pit furnished with dust free direct barite mixing system, for continous mixing of 3.09.31 barite direct into active- and reserve pit 3.09.32 Deck hopper or equivalent for mixing of big bags installed (Y/N) 3.09.33 Possible to take suction for the mud pumps from all pits 3.09.34 A gumbo trap installed on flowline before shaker box 3.09.35 Brine tank have recirculation possibility The derrick ventline ,separator and liquid seal capacity to handle a gas flowrate of : 3.09.36 (l/sec)
3.10
Y Y Y Y Y Y Y Y TBD
DRILLING WELL CONTROL SYSTEM & MARINE RISER
Blowout preventer general: 3.10.1 Make 3.10.2 Dimension (inches) 3.10.3 Working pressure (psi) 3.10.4 Choke/kill outlets 3.10.5 Design temp min./max. ( o C) 3.10.6 No. of rams 3.10.7 No. of annulars 3.10.8 4 year inspection performed (date) Wellhead connector: 3.10.9 Make 3.10.10 Fluid volumes open/close/secondary (g) 3.10.11 The wellhead connector profile suit Vetco H4 profile 3.10.12 Hydrate protection seal
TBD 18 3/4" 15,000PSI 1/1 75 6 2 N/A TBD TBD Y TBD
Page 11 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM
TECHNICAL SPECIFICATION / DETAILS FOR RIG
3.10.13 Glycol injection in connector Pipe rams: 3.10.14 Open/close volume (g) 3.10.15 Temp.rating max. min. ( o C) 3.10.16 Fixed high temp. ram for relevant pipe. No. of: 3.10.17 Variable ram blocks for relevant pipes 3.10.18 Variable rams in 2 cavities. 3.10.19 Mechanical ram lock system for pipe rams Shear rams: 3.10.20 The shear rams shall be able to shear and seal on minimum specified tubulars 3.10.21 Open/close volume ram 1(g) 3.10.22 Cylinder size ram 1 3.10.23 Type shear ram blocks ram 1 3.10.24 Open/close volume ram 2(l) 3.10.25 Cylinder size ram 2 3.10.26 Type shear ram blocks ram 2 Cameron super shear ram 3.10.27 Temp. rating max./min. ( o C) 3.10.28 Pressure to shear subject drill pipe (psi) 3.10.29 Pressure to shear Expro shear sub 3.10.30 Pressure to shear 13 5/8" csg 3.10.31 Spare blocks (Y/N) 3.10.32 Mechanical ram lock system for shear rams.
TBD 15.76/16.77 TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD
Page 12 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 3.10.33 3.10.34 3.10.35 3.10.36 3.10.37 3.10.38 3.10.39 3.10.40 3.10.41 3.10.42 3.10.43 3.10.44 3.10.45 3.10.46 3.10.47 3.10.48 3.10.49 3.10.50 3.10.51 3.10.52 3.10.53
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Upper annular preventer: Make/type Open/close volume (g) Temp. rating ( o C) Pressure rating (PSI) Outlet under UAP Lower Annular preventer: Make/type Open/close volume (g) Temp.rating (o C) Pressure rating (PSI) Lower Marine Riser Connector: Make/type Open/close/sec.open volumes (l) Max. disconnect angle (deg.) High angle release Flex joint: Make/type Min. I.D. (in) Max. bending angle (deg.) Kill & Choke valves: Make/type Open/close volume (g) Min. I.D. (in) Temp. rating (o C) Hydraulic press. assist close on remote operated valves
TBD TBD TBD TBD TBD TBD TBD TBD TBD 18-3/4" Style HAR TBD TBD TBD 8-3/4" -10M TBD 10 TBD 2.00/2.00 TBD TBD TBD
Able to close against dynamic flow w/surface controlsystem not intact 3.10.54 3.10.55 Able to close the valves with full flow through valve Choke/kill coupling between LMRP/BOP: 3.10.56 Make/type Choke/kill line flexible loops Subsea BOP: 3.10.57 Make/type 3.10.58 Material 3.10.59 H2 S resistant 3.10.60 Connection type. Clamp or flange. 3.10.61 Last certified (date) BOP control system: 3.10.62 Main control unit make/type 3.10.63 Surface accumulator size, ea bottle 3.10.64 No. of surface accumulators 3.10.65 Accumulator working pressure 3.10.66 BOP stack mounted bottles, size ea. 3.10.67 Accumulator working pressure 3.10.68 No. of BOP stack mounted bottles 3.10.69 BOP hydraulic fluid system closed system (e.g no dump to sea) 3.10.70 Hydraulic fluid type
TBD TBD TBD TBD TBD Y TBD N/A MUX TBD TBD TBD TBD TBD TBD TBD TBD
Page 13 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 3.10.71 3.10.72 3.10.73 3.10.74 3.10.75 3.10.76 3.10.77 3.10.78 3.10.79 3.10.80 3.10.81 3.10.82 3.10.83 3.10.84
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Hydraulic fluid system open return to sea (Y/N) Optional BOP fluid accepted by SFT Fluid mixing system Power fluid tank (g ) Control fluid tank (g ) Antifreeze fluid tank (g ) No. of air operated pumps No. of el. operated pumps Regulators on H.P. unit unaffected by loss of control signal Safety device on W.H. connector unlatch Retrievable pods Age of BOP control bundles Length of BOP control bundles (ft) Spare signal in each bundle (Y/N)
TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD N/A 11,000 TBD
Page 14 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 3.10.85 3.10.86 3.10.87 3.10.88 3.10.89 3.10.90 3.10.91 3.10.92 3.10.93 3.10.94 3.10.95 3.10.96 3.10.97 3.10.98 3.10.99 3.10.100 3.10.101 3.10.102 3.10.103 3.10.104 3.10.105 3.10.106 3.10.107 3.10.108 3.10.109 3.10.110 3.10.111 3.10.112 3.10.113 3.10.114 3.10.115 3.10.116 3.10.117 3.10.118 3.10.119 3.10.119 3.10.120 3.10.121 3.10.122 3.10.123 3.10.124
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Accoustic backup system: Make/type Accoustic backup system to operate at max. water depth for the rig (Y/N) BOP mounted accumulators (size) BOP mounted accumulators (no.) Accumulator working pressure Fixed control unit Portable control unit Retrievable accoustic package (Y/N) Functions connected to the accoustic system Locking system on rams if separate LMRP connector unlatch Shear rams close Upper pipe/shear rams close Middle pipe rams close Lower pipe rams close Choke Manifold: Make/type Working Pressure (psi) H2S service No. of remote chokes No. of manual chokes Glycol injection upstream choke(Y/N) Up/downstream pressure monitoring (Y/N) Up/downstream temperature monitoring (Y/N) Remote operated valves (no) Outlet downstream to poorboy degasser Outlet downstream direct to well test burner booms Possible to flowcheck outlet from poorboy degasser on trip tank (Y/N) Function of the BOP kill and choke lines interchangeables Separate pressure gauges for the kill and choke lines can be read independently and simultanously from the drillers house. High accuracy. Diverter System: Make/type Nominal size (in) Working pressure (psi) Design temp. (o C) Packer insert ID/ranges No. of lines No. of bends and corresponding angels Diverter closing time (sec) Integrated to BOP control system Diverter line diameter ID (in) Flowline diamter ID (in) Auto sequence when closing diverter The valves in the diverter system remotely operated (Y/N)
Page 15 of 27
TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD 15,000 Y 2 2 Y Y Y Y Y Y Y TBD Y TBD 75 1/2" 500 TBD TBD 6 TBD TBD TBD 16" 16" Y Y
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 3.10.125 3.10.128 3.10.129 3.10.130 3.10.131 3.10.132 3.10.133
TECHNICAL SPECIFICATION / DETAILS FOR RIG
All regulators in control system remain unaffected in the event of loss of power supply in loss of regulation air/fluid Sub sea TV monitoring system: Make/type No. of cameras Winch capacity Depth metering (Y/N) Control location Monitor in operator office
Page 16 of 27
Y N/A N/A N/A N/A N/A N/A
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 3.10.134 3.10.135 3.10.136 3.10.137 3.10.138 3.10.139 3.10.140 3.10.141 3.10.142 3.10.143 3.10.144 3.10.145 3.10.146 3.10.147 3.10.147 3.10.149 3.10.148 3.10.149 3.10.150 3.10.152 3.10.155 3.10.156 3.10.157 3.10.158 3.10.159 3.10.160 3.10.161 3.10.162 3.10.163 3.10.164 3.10.165 3.10.166 3.10.167 3.10.168 3.10.169 3.10.170 3.10.171 3.10.175 3.10.172 3.10.177 3.10.173
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Surface TV monitoring system: No. of cameras Camera on drill floor Camera in moon pool (Y/N) Camera in shaker room Camera in derrick Camera in pump room (Y/N) Monitor in drillers house Monitor in toolpushers office (Y/N) Monitor in operator office Signal cables from ROV units to drill floor Marine Drilling Riser General: Make/type Min. design temp. (o C) Max. water depth (ft) Min. temp. rating seals (o C) Min. I.D. (in) Tapered cross sectional changes Riser Anti Collapse valve or equal Riser anti recoil system Instrumented riser joint Riser hang off and support system Upper flex joint/ball joint: Make/type Max. load capacity (t) Max. angular deviation (deg) Min. I.D. (in) Telescopic joint: Make/type Min. I.D. (in) Dimensions - extended (ft) Dimensions - collapsed (ft) Capacity collapsed/locked (t) Capacity extended (tt) Type of sealing elements top Type of sealing elements bottom Riser pressure rating (psi) Pressure rating on seal elements (psi) Flexible kill and choke lines: (Cellar deck) Make/type Pressure rating (psi) Type connection. Hub or flange. Bend restrictors H2S resistant Temp. rating (o C) Spare hose (Y/N)
26 Y Y Y Y Y Y Y Y Y TBD TBD TBD TBD TBD TBD TBD Y TBD Y TBD TBD 10 TBD TBD TBD 75 25 TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD
Page 17 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 3.10.174 3.10.175 3.10.181 3.10.176 3.10.177 3.10.178 3.10.179 3.10.187 3.10.180 3.10.181 3.10.182 3.10.183 3.10.184 3.10.185 3.10.186 3.10.187 3.10.188
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Last inspection (certified) by supplier (date) in moonpol shall be certified prior to entering Contract) MarineRiser sections: Make/type Size OD (in) No.of joints Connection type Length (ft) Pup joint lengths/no. of (FT) Coupling type Choke/kill line press. rating (psi) Choke/kill line temp. rating Choke/kill line H2 S resist Buoyancy modules total length (FT) Buoyancy type Handling & test tools Miscellaneous: ROV hotstab. for operating certain BOP functions BOP service crane/work platform (Y/N) Able to do a full pressure test and function test of the BOP/LMRP on test stump.Hydraulic test station.
TBD TBD 21 134 TBD 75 TBD TBD 15000 75 Y TBD TBD TBD Y Y Y
Page 18 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 3.10.189 3.10.190 3.10.191 3.10.192 3.10.193 3.10.194 3.10.195 3.10.196 3.10.197 3.10.198 3.10.199 3.10.200
3.11 3.11.1 3.11.2 3.11.3 3.11.4 3.11.5 3.11.6 3.11.7 3.11.8
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Service trolley over moon pool Guidance system for BOP through moon pool. Handling system make/type Handling system capacity (t) Retractable test stump Test valves on C/K line on LMRP Jacks on LMRP BOP reinforcement Pressure and temp. probe under LMRP BOP max. footprint for HOST 4,5m x 3,8m Quick annulus dump system Emergency BOP recovery system
N Y TBD 550 Y TBD TBD TBD TBD TBD TBD TBD
COMPENSATING SYSTEM Top mounted heave comp. (Y/N) Static load capacity (lb) Dynamic load capacity (lb) Compensating length drillstring (ft) Riser tensioner, max. total force (lb) Compensating length riser tensioner (ft) Guideline tensioners, max. total force (KN) Comp. length guideline tensioner (ft)
3.12
HANDLING OF SUBSEA EQUIPMENT
3.11.1 3.11.2 3.11.3
Skid system for transport of Xmas trees (Y/N) Transfer skids for storage of modules (Y/N) Trolley capacity (t)
3.11.4
Power
3.13
HYDRAULIC POWER UNIT
3.13.1 3.13.2
Make, type Ring line's pressure (PSI)
3.14
DRILL STRING COMPONENTS
3.14.1 3.14.2 3.14.3 3.14.4 3.14.5 3.14.6 3.14.7 3.14.8
Kelly (Kelly) saver sub (Y/N) 6 5/8" OD drill pipe S-135 (ft) 5 7/8" OD drill pipe S-135 (ft) 5" OD drill pipe S-135 (ft) 3 1/2" OD drill pipe S-135 (ft) 5 7/8", 3 1/2" DP pup jnt. S-135 5 7/8" HW DP
Y 2 500 000 1 000 000 25 16 861KN 33 240mm TBD 2800mm
Y Y 2X75 Hydraulic:225 l/min 200bar Electrical:230VAC/60HZ/20A
3X94KW,6X94KW 207BAR
N N TBD TBD TBD TBD TBD TBD
Page 19 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 3.14.9 3.14.10 3.14.11 3.14.12 3.14.13 3.14.14 3.14.15 3.14.16 3.14.17 3.14.18 3.14.19 3.14.20 3.14.21
TECHNICAL SPECIFICATION / DETAILS FOR RIG
9 1/2" spiral DC 8 1/4" spiral DC 6 3/4" spiral DC 4 3/4" spiral DC Circulating heads for relevant DP Kelly cocks for 3 1/2" and 5 7/8" DP Inside BOP 5 7/8" Dart Sub w/dart Float valves (no orifice) to fit bit subs Bit subs bored for float to fit all bit size Cross over subs Bit breakers (26", 17 1/2", 12 1/4", 9 7/8", 8 1/2", 6") Bit gauges (26", 17 1/2", 12 1/4", 9 7/8", 8 1/2", 6"
3.15
FISHING EQUIPMENT
3.15.1 3.15.2 3.15.3 3.15.4 3.15.5 3.15.6
Overshots (11 1/4", 8 1/8" and 5 3/4") Jars (8", 6 1/2") Intensifier/accelerator (8", 6 1/2") Bumper subs (8", 6 1/2") Junk subs Reverse cir. junk basket
TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD
TBD TBD TBD TBD TBD TBD
Page 20 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 3.15.7 3.15.8 3.15.9
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Junk mills (12 1/8", 8 3/8", 5 7/8") Taper taps Ditch magnet (Y/N)
3.16
CASING HANDLING
3.16.1
Remote operated handling tools for CSG sizes. including 22" casing to be run in moonpool offline
TBD TBD TBD
Y BOP side
3.17
WELL TESTING SYSTEM
3.17.1 3.17.2
Production stand pipe and production flowline from drillfloor to test area ,choke manifold : Pressure rating (bar) Nominal OD (in)
3.17.3 3.17.4 3.17.5 3.17.6 3.17.7 3.17.8 3.17.9 3.17.10 3.17.11 3.17.12 3.17.13 3.17.14 3.17.15 3.17.16 3.17.17 3.17.18 3.17.19 3.17.20 3.17.21 3.17.22 3.17.23 3.17.24 3.17.25 3.17.26
Production flowline between choke manifold and heater: Pressure rating (bar) Nominal OD (in) High pressure gas line from test area to burner booms: Pressure rating (bar) Nominal OD (in) Low pressure gas line from test area to burner booms: Pressure rating (bar) Nominal OD (in) Flame arrestor installed Oil/condensate line from test area to burner booms: Pressure rating (bar) Nominal OD (in) Piping general: All pipes from drillfloor to booms H2S service All lines have drain points at lower sections Flowside outlet connection to be 4 1/16" Cameron hub no. 6 (suitable for Coflexip flow hoses) with connection mounted up in derrick Burner boom manifold valves (Threeway, Y/N) Diverter system independent of test system Burner booms: Length (ft) Slewing angle (Deg) Burner head weight (expected load) (lb) Design temperature (0 C) Ice load (lb) Cooling water supply: Capacity (burner head) (GPM) Capacity of burner water sprinkler shield (GPM) Sprinkler shield (ring) distance from burner head (ft) Capacity (rig cooling) (GPM) Electrical equipment: Zone classification
Page 21 of 27
15000PSI 5"
5000PSI 4" 300PSI 4" 125PSI 2" Y 200PSI 2" Y Y Y Y Y 30M 120 TBD TBD N TBD 5.15M3/M TBD 350M3/H SAFE AREA
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM
TECHNICAL SPECIFICATION / DETAILS FOR RIG
3.17.27 Electrical supply (stabilized), test area (V/Hz) Instrument air supply: 3.17.28 Pressure (bar) 3.17.29 Volume (GPM) Steam supply: 3.17.30 Pressure (bar) 3.17.31 Temperature (℃) 3.17.32 Volume (ft3/hr)
480V 60HZ 7.0 TBD TBD TBD TBD
Page 22 of 27
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM
4 4.01 4.01.1 4.01.2 4.01.3
4.01.4 4.01.5 4.01.6
TECHNICAL SPECIFICATION / DETAILS FOR RIG
GROUP 4 - HSE HEALTH CARE SYSTEM No. of hospital berths First aid cabinet at: Drillfloor, mud pump room, engine-/ control room, and gally Eye wash station at: Drill floor, mudpump-, cement unit-, shale shaker-, mixing hoppers-, hydraulic room, health office and sack storage area for chemicals Emergency area ( for sorting and preliminary treatment of injured personel in case of major accidents) located so that safe stretcher transport of injured personel is possible to and from the area. Total no. of stretchers Hoisting equipment for stretchers
4.02
LIVING QUARTERS
4.02.1 4.02.2
All upper beds equipped with arrangement to prevent people from falling out of bed Individual temperature regulation possible in bedrooms
4.02.3 4.02.4 4.02.5 4.02.6
Living quarter has a positive pressurised system No. of offices, operator personnel Total no. of working places at operator offices Provision store rooms: Direct access to/from workdeck
4.03
1 Y Y
Y 3 Y
Y Y To guarantee the overpressure 50Pa of the accommodation against outside, the accommodation rooms will be sealed from the corridors. The corridors will be also supplied and exhausted with air-conditioned air, The overpressure 50Pa in corridor will be controlled by air difference between supply capacity over exhaust capacity. TBD TBD Y
FIRE AND GAS PROTECTION SYSTEM Fire and gas detection/alarm system:
4.03.1 4.03.2 4.03.3 4.03.4 4.03.5 4.03.6 4.03.7 4.03.8 4.03.9
System test facilities provided System of a self-diagnostic type where failure in any detector or field cable is indicated by a fault alarm in the main control centre Smoke detectors of ionisation type and installed in enclosed areas where combustible and electric fires may develop, e.g. switchgear, control, and power generating rooms and accomodation area Smoke and heat detectors equipped with selfcontained alarm indicators that once activated remain illuminated until reset Continously monitoring gas detectors (intermittent monitoring not acceptable) Gas detection monitored in main control room, drillers console drill floor and pilot house
Test gas bottble,Test gas unit,heat detector test kit,Test magnet for flame detector, Testkey for BF-501 and BF-502/N.EX,Test equipment for H2S gas detector test gas 50ppm H2S,Calibration kit for H2 gas detector,Hydrogen 50% LEL
Min. one of the gas detection monitoring panels indicates gas concentration in LEL No of flainable gas/H2S detectors installed in: Mud room Rig-up area
Page 23 of 27
Y Smoke detector is optical type Y Y Y Y Gas detector 14 pcs, H2S detector 3 pcs Gas detector 24 pcs, H2S detector 18 pcs
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM 4.03.10 4.03.11 4.03.12 4.03.13 4.03.14 4.03.15 4.03.16 4.03.17 4.03.18 4.03.19
TECHNICAL SPECIFICATION / DETAILS FOR RIG
Drill floor Shale shaker room Pump room Air intake for safe areas Fire water pump system: Riser piping frost protected and routed inside the superstructure to minimize the risk of mechanical damage Automatic pressure release valve on fire water pumps Automatic open/close of suction/discharge and overflow valves Suction lines from sea chests provided with two valves, and one of the valves remotely operated Manual/remote activation from helideck Manual/remote activation from main control center
Page 24 of 27
Gas detector 10 pcs, H2S detector 7 pcs Gas detector 6 pcs, H2S detector 2 pcs N/A Gas detector 84 pcs, H2S detector 23 pcs
N Y Y Y Y Y
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM
TECHNICAL SPECIFICATION / DETAILS FOR RIG
4.03.20 Manual activation locally at pump Possible to stop system only from coinand centre, main control centre and locally at 4.03.21 pumps Fire water ring main: 4.03.22 4.03.23 4.03.24 4.03.25 4.03.26 4.03.27 4.03.28 4.03.29 4.03.30 4.03.31 4.03.32 4.03.33 4.03.34 4.03.35 4.03.36 4.03.37 4.03.38 4.03.39 4.03.40
Pressure regulating devices installed at points where high pressure can be dangerous Water deluge system: Installed at areas for processing and conveying of hydrocarbons Installed at lifeboats Installed at liferafts Installed at helifuel tanks Installed at helifuel hose space Installed at structure exposed to flare-booms Installed at flare-booms Installed at drilling area Separate connection to fire water ring main for sections covering drilling areas Deluge system frost protected Deluge valves located close to, but outside areas served by the valves, readily accessible and close to escape routes Pipework designed to ensure a uniform distribution of seawater over the protected areas The design ensures adequate drainage of the pipework Local activation of deluge system possible Sprinkler system in accomodation activated by heat sensitive frangible bulbs Helideck fire extinguishing system: Min. discharge (m3/h) Range/monitor (ft) Monitors supplied with a dedicated aqueous film forming foam (AFFF) or synthetic compound Other requirements:
4.03.54
Escape breathing masks of Statoil approved type (i.e. Dräger Parat C) at each bed Radioactive sources and explosives to be stored seperately and easily available, minimum 15m apart Explosives stored at a location where easily available for removal overboard in an 4.03.56 emergency situation 4.03.57 Insulated handles on CO2 fire-fighting apparatus 4.03.58 Water monitors covering drill floor and accomodation area 4.03.55
4.04
HELICOPTER LANDING SYSTEM
4.04.1
Helideck designed for: Drainage system with sufficient capacity to enable draining of all fluid resulting from the use of all fire extinguishers simultaneously on or near the helicopter/landing system Helicopter fuel system: Pump capacity (G/min) Fuel hose coupling of "single point" type for closed systems
4.04.2
4.04.3 4.04.4
Page 25 of 27
Y Y
Y N Y N foam N Y Y Y Y Y Y Y Y Y Y 0.36 Φ72
AFFF
TBD Y Y Y Y
S-61
Y 60 Y
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM
TECHNICAL SPECIFICATION / DETAILS FOR RIG
4.04.5 4.04.6 4.04.7
Designed for cold and hot refuelling Operating temperature (oC) Length of hose sufficient for refuelling anywhere on helideck
4.04.8
Equipped with API-approved filter seperator and a filter monitor of a type that seperates solid particles and automatically stops the fuelling if the fuel contains water Pressure gauge installed between the final filter (monitor) and the fuel hose reel. Differential pressure gauge both on filter seperator and filter monitor
4.04.9
Y 45℃ Y
Page 26 of 27
Y Y
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG REF.NO. ITEM
TECHNICAL SPECIFICATION / DETAILS FOR RIG
4.04.10 Transportable fuel tank connected to pump system via a flexible hose with stainless steel armouring and a dust cover on the coupling when it is not connected Non-return valve installed on the pressure side of fuel pump. If two pumps, both have 4.04.11 a seperate non-return valve 4.04.12 All components earthed 4.04.13 Permanent ladder on tanks with internal height exceeding 1400in Meter on fuel system with reading in litres both for total amount and for each individual 4.04.14 refuelling. Resetting of meter possible 4.04.15 Helifuel back-up pump
4.05 4.05.1 4.05.2 4.05.3 4.05.4 4.05.5 4.05.6 4.05.7 4.05.8 4.05.9 4.05.10 4.05.11 4.05.12 4.05.13 4.05.14 4.05.15 4.05.16 4.05.17 4.05.18 4.05.19 4.05.20 4.05.21
Y Y Y Y Y N
RESQUE AND SAFETY EQUIPMENT Lifeboat stations: Equipped with P.O.B.-lists, axes and knifes Emergency lights also covering lifeboat winches Protected against heat radiation from an ignited gas/fire blowout Seperate davit for MOB-boat Lifeboats/-rafts: No. of covered lifeboats Capacity each lifeboat Capacity of each liferaft Escape ways: All clearly marked with luminous signs, and on deck, stairs etc. marked with paint (width 80 cm) Treated with non-skid material Sufficent drainage in order to avoid water pools to occur 2 seperate escape ways from drillers cabin Protected against heat radiation from an ignited oil/gas blowout Other requirements: Survival suits equipped with marking lights Life jackets equipped with light reflecting stripes Life buoys equipped with igniting light attachment and self-activating smoke signal Chargeable emergency lights in corridors in living quarter One mobile search light placed in moonpool area, and one in MOB-boat All safety equipment clearly marked with illuminating materials Derrickman escape chute Passages and stairways provided with hand rails All decks enclosed by safety railings
Y Y Y Y 4 80 P 25 P
Y Y Y Y Y 170 P 320 P 14 Y Y Y Y Y Y
Page 27 of 27