The presentation: Monsanto coming to Europe is a failed mission. Not only that most GMOs are not allowed in Europe, most of the farmers don't even grow the one that are. An analysis of misu…Full description
heal
FYP presentationFull description
Wireless energy transfer is a very exciting technology which promises to radically change the way we perform any activity. In this report I like to explore the concept of transmitting power …Full description
FiCA presentation in MS Power PointFull description
oliverDescripción completa
Clarisse The Label Thesis Presentation by Clarisse Provido
OTIS GEN 2 COMFORT
Full description
Full description
Presentation Goodridge
Green Building Design Evaluation System
fair presentationFull description
Full description
strenghening
Full description
HPD PDM M Axia Axiall lly y Sp Spli litt Volu Volute te Cas asin ing g Pu Pump mps s
Sulzer Pumps
The Heart of Your Process
HPDM
Sulzer Pumps
(1000 US gpm) 10 20 40
Range Chart
5
100
1000
3000
800 600
2000
HPDM 2d
) m400 (
(feet) HPDM 1d
d a 300 e H
1000
HSB
200 500 100
300
SM 1
5 10 Flow (1000 m3/h)
20
MyPresentation | slide 2
HPDM
Sulzer Pumps
Impeller arrangement
1d
2d
3d
s+s
d+s
D +2s
2D
MyPresentation | slide 3
HPDM
Sulzer Pumps
Designs
1d
2d
s+s MyPresentation | slide 4
HPDM
Sulzer Pumps
Sulzer's Strength
Highly engineered pumps designed to customers requirements
High power pumps
References
MyPresentation | slide 5
HPDM
Sulzer Pumps
Main Design Data Service Hydraulics
Water
nq11.3 (582) to nq42.1(2170)
Case design Bolting Design Standards Shaft seal Bearing arrangement Max. Design pressure Max. Design temperature Max. Power
Oil
Axially split with gasket Cap nuts with hydraulic tightener & Super Bolt Sulzer
API 610
Packing gland & MS
Mechanical seal
Antifriction & forced feed journal / thrust for..1d → 150 bar (2175 psi) for..2d → 100 bar (1450 psi) 50 °C ( 122F) so far up to 18MW
MyPresentation | slide 6
Makkah Taif Water Transmission System
Sulzer Pumps
MyPresentation | slide 7
Water Supply System for Mecca and Taif (Saudi Arabia) Operator:
Sulzer Pumps
SWCC (Saline Water Conversion Corp.), Riyadh, Saudi Arabia
Ordered by: Al Rashid/Hak Consortium, Riyadh, Saudi Arabia Planning:
ILF, Innsbruck Austria
Pump type
Q (m³/h)
H (m)
P (kW)
8 x HPDM 300-600
1‘782
70
397
8 x HPDM 250-375
1‘782
485
2‘732
4 x HPDM 250-425
1‘332
340
1‘448
4 x HPDM 250-420
1‘332
575
2‘449
4 x HPDM 250-420
1‘332
645
2‘748
MyPresentation | slide 8
Water Supply System Cutzamala, Mexico-City, Mexico Operator :
CAVM (Comisión de Aguas del Valle de México)
Ordered by:
CAVM
Planning:
CAVM and Ipesa Consultores S.C., México
Pump type
Q(m3/h) H(m) rpm
11 x HPDM 750-945-1d/37
14400
160 1200
6930
6 x HPDM 800-865-1d/46
14400
122 1200
5370
12 x HPDM 700-1010-2d/33
14400
350 1200 15390
3 x HPDM 500-620-1d/38
6120
158 1800
2990
3 x HPDM 450-710-1d/29
5760
213 1800
3780
Sulzer Pumps
P(kW)
MyPresentation | slide 9
Water Transport System El Pao La Balsa, Venezuela
Sulzer Pumps
Operator:
Hidrocentro
Ordered by:
INOS
Planning:
INOS and sub-consultants
Q(m3 /h) H(m) rpm
Pump type P(kW) 6 x HPDM 600-830-3d/36 8100 3 x SMV 802-1030-1d/36
350
1200 8500
47
590 1226
8640
One of the three vertical booster pumps, type SMV 802-1030-1d/36, installed in the booster pumping station.