PAN India Presence Jammu & Kashmir Jammu Amritsar Ludhiana Chandigarh
Mandi Himachal Pradesh Punjab
Jaipur Jodhpur Barmer
Kanpur Gwalior Ajmer Udaipur
Gandhinagar Ahmedabad Mehsana Sanand Mundra Jamnagar Rajkot Baroda Ankleshwar Surat Vapi
Haryana
Hisar Delhi
Uttara khand
Rajasthan
Madhya Pradesh
Gujarat
Nashik Mumbai Pune
Maharashtra
Nagpur Belgaum
Dehradun Moradabad
Grid Tied Solar Inverter
Siliguri Guwahati Gorakhpur Arunachal Pradesh Allahabad Muzzafarpur Gopalganj Jorhat Ranchi Uttar Pradesh Sibsagar Meghalaya Bihar Sasan Patna Korba Jharkhand Agartala Bokaro West Bengal Kolkata Jamshedpur Jajpur Angul Chattisgarh Bilaspur Cuttak Orisaa Bhubaneswar Raipur Bhilai Lucknow Indore Bhopal
HIVERTER - NP201i Series
Hyderabad Vizag Rajahmundry
Andhra Pradesh
Bellary Kadapa
Karnataka Udipi Bangalore
Chennai
Mangalore Coimbatore Karaikal
Palakkad
Tamil Nadu Kerala Tiruneveli Thiruvananthapuram
Manufacturing Plant Corporate Office Branch Office Service Center
Global Presence Middle East l South East Asia l Africa l Australia l America ca
Hitachi Hi-Rel Power Electronics Pvt. Ltd. Gandhinagar Works B - 14/1 & 171, GIDC Electronics Zone, Sector - 25, Gandhinagar - 382 044 Gujarat, India. Phone: +91-79-2328 7180/81, 6170 0500, Fax: +91-79-2328 7182 Sanand Works SM 3 & 4, Sanand - II GIDC, Industrial Estate, Bol Village, Sanand - 382 110 Gujarat, India. Phone: +91-2717-678777, Fax: +91-2717-678700
4 2 3 2 2 0 0 3 9 7 0 t h g i l t o p
S a i d n I / g t k M . p r o C / 1 . r e V / 4 1 / 2
l
Grid Tied Solar Inverter HIVERTER - NP201i Series
HIGHLIGHTS The Hitachi Solar Inverter is a Grid Tied (GT) Solar Inverter with reactive power control and high efficiency, which is the heart of the Solar Power Generating System. It converts DC power generated by the Photovoltaic (Solar) Array to AC power that is fed to the Utility Power Grid System. The Hitachi Solar Inverter is fully compatible with thin film and / or crystalline PV modules. With proper maintenance and parts replacement on schedule it has an operating life upto 25 years. As a part of Hitachi Group Company, Hitachi Hi-Rel Power Electronics Pvt. Ltd (HHPE) is manufacturing Grid Tied Solar Inverters in India based on the contemporary technology of Hitachi Ltd, Japan. It brings reliable products supported by very high quality standards, manufacturing processes and work culture. Assured long term technical and spares support.
HIVERTER NP 201i, Hitachi Solar Inverter Series are among the best available GT Solar Inverters that are suitable for Multi-Megawatt Solar Power Plants. The transformer-less design and 3-level PWM technology improves the efficiency of the system to 98.7%. The Inverter has a compact design and lower weight for ease of installation, repair and maintenance. The large touch screen display collects real-time data and provides fault detection diagnostics to ensure faster retrieval of information for corrective action.
Three Level High Frequency PWM Inverter Technology resulting in Reduction of Losses, Low Harmonic Output Current (< 3%) & Improved Efficiency ¡ High Efficiency up to 98.7% Including Filter Losses ¡ IEC compliant / Third Party Approval for Entire Range of Inverters ¡ Reactive Power Control ¡ Low Voltage Ride Through (LVRT) Functionality ¡ Propriety MPPT Algorithm / Extra Wide MPPT Range (460 V – 900 V) ¡
Optimized Cooling Fan for Higher Energy Savings as well as Longer Fan Life ¡ Integrated DC and AC Distribution & Protection ¡ Independent RS 485 and TCP/IP Communication Interfaces ¡ Compact Product Design for Lower Footprint and Ease of Installation ¡ Designed Lifetime up to 25 years - With Preventive Maintenance and Periodic Parts Replacement ¡
HITACHI'S PRESENCE IN INDIAN SOLAR DOMAIN State of the art Manufacturing Facility in India at Sanand and Gandhinagar in Gujarat ¡ Comprehensive Testing Facility with 100% Load Test ¡ Life Cycle Service Support through Hitachi's Pan India ServiceCentres ¡
Prompt availability of Spares and Components locally in India ¡ Over 90 MW Hitachi Inverters feeding Power to Indian Grid in Various States
¡
99.5% 99.0% 88F INVERTER
6C
PV panel (Bottom)
(Bot tom)
72
42
AC 415V , 3- Ph as e
98.5%
Grid 52M
DC460
98.0%
y c n97.5% e i c i f 97.0% f E
(Bot tom) AC300 V 3Ø 3W
~900V
ControlCircuit
96.5% ControlPower SupplyCircuit
8A
(Bot tom)
8G
(Bot tom)
AC 240V ,1 - Ph a se or DC110V
96.0% 95.5% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 10 0%
Output Power
KW Solar Inverter
MW Solar Inverter
Single Line Diagram of PV-Solar Inverter
Output Power Vs. Efficiency Curve
Grid Tied Solar Inverter HIVERTER - NP201i Series
CONTROL FUNCTIONS
TECHNICAL SPECIFICATIONS (KW SCALE)
Start / Stop Function (Emergency Switch) a. Inverter START / STOP Switch or Contact Input Signal (Start and stop of the Inverter is carried out by START / STOP switches). b. Control position can be selected by DIRECT / REMOTE Switch. Direct Control Direct control of the Inverter is possible by using START / STOP Switches. Remote Control Remote control of the Inverter can be done by contact input signals (START / STOP Switches) or communication. Fault Ride Through (FRT) – Low Voltage Ride Through (LVRT) Against sudden changes of amplitude or phase of AC Voltage, Inverter high-speed detection and control capability can prevent AC over current.
PV Input Controlled Stand-by Function a. When the DC input power or voltage reduces due to decrease in solar irradiation or any other causes, the Inverter goes into stand-by mode with its inverter switching functions turned off automatically. In this case, the DC switchgear will be closed.
Monitoring(Indicators) Inverter Status measurement data, Fault data, Historical records and other information is displayed on the LCD screen. Status: Inverter Status l Switchgear Status l Grid Status Measurement AC Output : Voltage l Current l Power l Power Factor l Frequency DC Input : Voltage l Current l Power Fault Data : Inverter Failure l Grid Faults HistoricalRecords Operation Record l Grid Trouble Record l Fault Record
Grid Data Power Rating
Output Power Limiting Function When the Hitachi inverter output exceeds its maximum value, the input power drawn will be adjusted to prevent the inverter from being overloaded.
Maximum AC Current Output Waveform THDi
1049 A
1107 A
Nominal Output Voltage
300 V ±10 %
EnclosureProtection Performance EMC
Environmental Testing
715 kW
1107 A
1107 A
370 V ±10 %
400 V ±10 %
< 3% 350 V ±10 %
50 Hz or 60 Hz ± 5% Transformer-less Design 98.7%
EURO Efficiency
98.4% 0.80 Lead to 0.80 Lag within max. kVA limit
Power Factor (Adjustable) PV Side 600 kW DC 460 to 900 V
Maximum DC Input Voltage (OC) Minimum DC Input Voltage Maximum Input Current DC
460 V
756 kW
806 KW
DC 525 to 900 V DC 550 to 900 V 1000 V (Heavy Failure Protection Level) 525 V
550 V
858 kW DC 600 to 900 V 600 V
1200 A
External Auxiliary Power Supply
Auto-tuning of power factor based on Grid conditions Fixed power factor (Can be set to Unity) Fixed amount of reactive power ¡ Can be based on a pre-set value or based on adjustable settings ¡
Control Power in Operation
¡
Control Power in Stand-by Mode
¡
Cooling Fan Power
AC 415V 3Φ, 400W
Protections Islanding Protection
Yes
Temperature Protection
Yes
Ground Fault Monitoring
Yes
Grid Monitoring
Yes
AC & DC Short Circuit and Over Current AC & DC Over Voltage and Temperature
Yes
Ease of Installation and Commissioning Low weight and compact footprint saves time and resources at site
Cooling (Controlled) Fault ride Through (FRT)
Circuit Breaker on AC Side ¡ ¡ ¡ ¡
Local PC automation and system controls I / O extensions. SCADA for Solar PV plants Auxiliary Power Supply solutions
Switch on DC Side Communication Visual Display Wired Local Monitoring Unit-wise Integrated Data Logging
Analogue Input / Output Digital Input / Relay Output
IEC 60529 IEC 61683 IEC 61000-6-2 IEC 61000-6-4 60068-2-1 60068-2-2 60068-2-14 60068-2-30
670 KW Three Phase
Transformer Peak Efficiency
Maximum DC Power MPPT Voltage Range
Reactive Power Control 3 Primary Types of Control Methods
715 kW
MPPT and AC Current Control 630 kW
Output Frequency Range
COMPLIANCE Safety Testing
670 KW
500 kW
Access Interface / Field Bus Connectivity
IEC 62109-1 IEC 62109-2 IEC 62116 UL 1741
630 kW
3 Level High Frequency PWM Solar Inverter
Control System
Reducing Grid Voltage Fluctuation Control Automatic Wake-up and Shut-down
OptionalAccessories ¡ Ready to install containerized Inverter units. ¡ Solar array junction boxes with string monitoring. ¡ Integrated DC input extension cabinet ¡ LT Panel
500 kW
AC Grid Connection
b. Upon recovery of the DC input the Inverter switching operation will be restored automatically.
With the feature, the Inverter can keep operating even under momentary voltage dip of 60% for up to 0.5 seconds. Maximum Power Point Tracking (MPPT) Control Inverter has a function to maximize power generation at a given amount of solar radiation by adjusting DC voltage.
Solar Inverter Rating AC-DC Conversion System
PV Inverter general PV Inverter safety requirements Islanding system Safety IP protection Efficiencycalculations Emission requirements Immunity requirements Cold test Dry heat test Change of temperature Damp heat cyclic test
Mechanical Dimensions (H x W x D) mm (Approximate) Weight (Kgs) (Approximate)
AC 230V, 1Φ, 300W, Max. 6.9A < 100 W
Yes Forced Cooling Available operation will be continued in case of momentary voltag e dip of residual positive phase. Voltage fluctuation due to power change at inter-connecting point will be reduced to within 2% Yes Yes Yes LCD Display with Touch Screen 1 x RS 485 or TCP/IP Yes RS 485 or TCP-IP (Ethernet) 3 (Optional) 4
1900 x 1400 x 1000 1200
Environmental Limits Enclosure Protection Temperature Range Relative Humidity Maximum Noise Level Altitude Cooling Air Flow
IP 20 (IP 21 Optional) (-) 20° C to (+) 60° C 15% to 95% (Non Condensing) 75 dBA at a distance of 1 Mtr (IEC 61672 - 1 Characteristic) 0 to 1000 Mtrs. (Option: 2000 Mtrs.) 3 3760 M/Hr.
Grid Tied Solar Inverter HIVERTER - NP201i Series
TECHNICAL SPECIFICATIONS (MW SCALE) Solar Inverter Rating
1 MW (1000 kW)
AC-DC Conversion System Control System Grid Data Power Rating
MPPT and AC Current Control 1000 kW
AC Grid Connection Maximum AC Current Output Waveform THDi Nominal Output Voltage Output Voltage Range
1.25 MW (1250 kW) 3 Level High Frequency PWM Inverter
1250 kW Three Phase
2214 A
2214 A <3% at rated current
300 V AC
350 V AC
300 V ± 10%
Output Frequency Range
350 V ± 10% 50 Hz or 60 Hz ± 5% Transformer-less Design
Transformer Peak Efficiency
98.4% at Min DC Input Voltage
EURO Efficiency
98.1% at Min DC Input Voltage
Power Factor (Adjustable)
0.80 Lead to 0.80 Lag within max. kVA limit
PV Side Maximum DC Power MPPT Voltage Range
1200 kW
1500 kW
DC 460 to 900 V
Maximum DC Input Voltage (OC)
DC 525 to 900 V 1000 V (Heavy Failure Protection Level)
Minimum DC Input Voltage
460 V
525 V
Maximum Input Current DC
2400 A
2400 A
External Auxiliary Power Supply Control Power in Operation
AC 230V, 1Φ, 600W
Control Power in Stand-by Mode Cooling Fan Power
<150W AC 415V 3Φ, 800W
Protections Islanding Protection
Yes
DC Reverse Polarity Protection
Yes
Temperature Protection
Yes
Ground Fault Monitoring
Yes
Grid Monitoring
Yes
AC & DC Short Circuit and Over Current AC & DC Over Voltage and Temperature
Yes
Cooling (Controlled)
Yes Forced Cooling
Fault ride Through (FRT) (Also known as LowVoltage Ride Through (LVRT))
Yes
Reactive Power Control
Yes
Automatic Wake-up and Shut-down
Yes
Circuit Breaker on AC Side
Yes
Switch on DC Side
Yes
Communication Visual Display Wired Local Monitoring Unit-wise Integrated Data Logging Access Interface / Field Bus Connectivity Analogue Input / Output Digital Input / Relay Output Mechanical Dimensions (H x W x D) mm (Approximate) Weight (Kgs) (Approximate)
LCD Display with Touch Screen RS485 Modbus / Modbus TCP-IP / TC P-IP over Ethernet Yes RS 485 or TCP-IP (Ethernet)
Relative Humidity Maximum Noise Level Altitude Cooling Air Flow
Incorporated in 1983 as Hi-Rel Electronics Pvt. Ltd., we are now a Hitachi group company - Hitachi Hi-Rel Power Electronics Pvt. Ltd., recognized as a PIONEER IN POWER ELECTRONICS. With 3 decades of experience, we have garnered a significant level of trust in our market segment and continue to offer world class power electronics products, value added services & customized solutions. Our Product Portfolio includes UPS (Uninterruptible Power Supply) for Industrial, Commercial & Enterprise Applications, Medium Voltage & Low VoltageVariableFrequency Drives, Steel Automation& Engineered Drives for Customized Applications, Industrial Automation & Control Products like PLC, SCADA & DCS, GRID TIED SOLAR INVERTER, Railway Products and other Customized Products like UMPS, iDip (dip ride through solutions), etc. We have rich experience in supplying Power Back-up Products & Complete Customized Solutions for Mission Critical Applications in Refineries, Petro-Chemicals, Power Generation, Steel & Metal, and Process Industries as well as Critical Data Processing Applications.
We believe that our core values, customer delight, quality orientation, harmony, sincerity, pioneering spirit & growth, differentiate us from others. With expertise, experience and an efficient product line, we will always be yourpower electronicspartner. When you choose to do business with us, you are partnering with a company who cares.
Gandhinagar,IndiaWorks n n
n
n
2
Total Area - 10,000 m Products Manufacturing - Industrial, Commercial & Enterprise UPS, Grid Tied Solar Inverter & Railway products Facilities - Designing, Engineering, Manufacturing and Testing In-house Product Testing Facility
3 (Optional) 4
< <
2078 x 2404 x 989 (additional width of 500 for Up to 16 protected inputs) <
2000 (additional 300 kgs for up to 20 protected inputs)
Environmental Limits Enclosure Protection Temperature Range
ABOUT US
<
IP 20 (IP 21 Optional) (-) 5°C to (+) 60°C (no de-rating up to 50°C; 1.5% de-rating per degree rise in temperature from 50°C to 60°C) 15% to 95% (Non Condensing)
<
75 dBA at a distance of 1 Mtr (JIS C 1509 Class 2 - A Characteristic) 0 to 1000 Mtrs. (Option: 2000 Mtrs.) 3
7520 M/ Hr.
< < < <
World Class Technology & Innovation from Hitachi, Ltd., Japan State-of-the-Art Manufacturing Facilities at Gandhinagar & Sanand in Gujarat, India Up to 80 MW Installations withing India and more than 1 GW Worldwide. In-house R&D (Research & Development) Facility, recognized by DSIR (Department of Scientific & Industrial Research), Government of India An ISO 9001:2008, ISO 14001:2004 & BS OHSAS 18001:2007 Certified Company, adhering to world class quality standards Approved by major consultants and EPCcontractors Serving entire gamut of industries PAN India & global presence Offer products with greater energy efficiency & lower carbon footprint
Sanand, India Works n n n n
n n
n n
Most Modern Power Electronics Manufacturing Facility in India Modelled on Hitachi's Omika Works, Japan 2 Total Area - 26,000 m Products Manufacturing - Medium & Low Voltage Drives, Industrial Automation & Control, Customized Products i.e. UMPS, iDip Facilities – Designing, Engineering, Manufacturing and Testing Use of Hitachi's Omika Works based Software Tools for Engineering and Manufacturing Dust Free Environment and Anti-static Flooring In-house Product Testing Facility