: The motor motor shou should ld be flame flame proof proof make make BB/CG BB/CGL L The make of Gear Gear Box shall shall be Elecon Elecon / Redic Redicon on / Shan Shanti ti Flush Bottom Bottom Valve Valve should should be flame flame proof, proof, pneumaticall pneumatically y operated operated and and with Thermosensor Thermosensor arrangement. Dip Dip pip pipe e for for Thermo Thermowe well ll to be prov provid ided ed..
DATA SHEET FOR REACTOR
F:\PROJECTS\HPLD\AO_NEW\DATASHEET\MSGLRECTOR
S.NO.
DESCRIPTION
TECHNICAL SPECIFICATION
1
Tag No.
AO-R-501(N)
2
Model
AE-2000 / JO-2000
3
Design Pressure in Vessel
- 1 to + 6 kg/cm²
4
Design Pressure in Jacket
- 1 to + 6 kg/cm²
5
Type of Agitator Fluid in Shell
Anchor O-xylene
7
Fluid in Jacket
Thermic Fluid / Hot Oil
8
Operating Temperature in Vessel
175°C
9
Operating Temperature in Jacket
250°C
10
Size of Bottom Flush Valve
100 x 80
11
Sealing arrangement
Stuffing Box
12
Shaft Sleeve material
Hast.C
13
Heat Transfer Area
*
14
Motor Rating / rpm
*
15
Gear Box size & make
*
16
Nozzle details
*
6
NOTE 1 2 3
: The motor should be flame proof make BB/CGL The make of Gear Box shall be Elecon / Redicon / Shanti Flush Bottom Valve should be flame proof, pneumatically operated and with Thermosensor arrangement.