Tipski projekat sa vazdusnim privodomFull description
Using GHS for product labels
cosmetic packaging
gfjtaFull description
Full description
Product Identifier (ingredient disclosure): Name or number used for a hazardous product on a label or in the SDS. Symbols (hazard pictograms): Convey health, physical and environmental hazard ...
Labeling instructions for RF Jumpers / Feeder From RF Module to Antenna :Labeling on Jumpers / Feeder between 900 RF Module ( FXJB ) and All three sectors Antenna Lable Text
Location
900-SEC1-ANTLN1
From GSM (2G) RF Module to Antenna 1 Feeder MAIN
900-SEC1-ANTLN2
From GSM (2G) RF Module to Antenna 1 Feeder Diversity
900-SEC2-ANTLN1
From GSM (2G) RF Module to Antenna 2 Feeder MAIN
Qty
2 2 2 2 2 2
900-SEC2-ANTLN2 From GSM (2G) RF Module to Antenna 2 Feeder Diversity 900-SEC3-ANTLN1
From GSM (2G) RF Module to Antenna 3 Feeder MAIN
900-SEC3-ANTLN2
From GSM (2G) RF Module to Antenna 3 Feeder Diversity
Labeling on Jumpers / Feeder between 2100 RF Module ( FRGU ) and All three sectors Antenna Lable Text
Location
Qty
2100-SEC1-ANTLN1 From WCDMA (3G) RF Module to SEC 1 Antenna Line 1
2 2 2 2 2 2
2100-SEC1-ANTLN2 From WCDMA (3G) RF Module to SEC 1 Antenna Line 2 2100-SEC2-ANTLN1 From WCDMA (3G) RF Module to SEC 2 Antenna Line 1 2100-SEC2-ANTLN2 From WCDMA (3G) RF Module to SEC 2 Antenna Line 2 2100-SEC3-ANTLN1 From WCDMA (3G) RF Module to SEC 3 Antenna LINE 1 2100-SEC3-ANTLN2 From WCDMA (3G) RF Module to SEC 3 Antenna LINE 2
Labeling on Jumpers / Feeder between 1800 RF Module ( FXEF ) and All three sectors Antenna Lable Text
Location
1800-SEC1-ANTLN1 From LTE (4G) RF Module to SEC 1 Antenna Line 1 1800-SEC1-ANTLN2 From LTE (4G) RF Module to SEC 1 Antenna Line 2 1800-SEC2-ANTLN1 From LTE (4G) RF Module to SEC 2 Antenna Line 1 1800-SEC2-ANTLN2 From LTE (4G) RF Module to SEC 2 Antenna Line 2 1800-SEC3-ANTLN1 From LTE (4G) RF Module to SEC 3 Antenna LINE 1 1800-SEC3-ANTLN2 From LTE (4G) RF Module to SEC 3 Antenna LINE 2
Qty
2 2 2 2 2 2
Note :-
1) All Labels used must be done in the same manner i.e. towards the termination point . 2) Label must be same on both the end of the cable i.e. For every label 2 Quantity of same label available in Label set .
Labeling instructions for Alarm and GPS Cable :-
Labeling on Alarm and GPS Cable Lable Text
Location
SRAN FSM-GPS
From System Module of LTE to GPS Antenna
SRAN FSM-ALM
System Module of LTE to Alarm Box/Tag Block
Qty
2 2
Label Text FR1 FR2 FR3 FR4
Labeling instructions for Optical Cable :Labeling on Optical Cable Location
Lable Text SRAN FSM-FR1
From FSMF of GSM (2G) to RF module 900 FXJB Optical cable OPT Port 1
SRAN FSM-FR2
From FSMF of WCDMA (3G) to RF module 2100 FRGU Optical cable OPT Port 1
SRAN FSM-FR3
From FSMF of LTE (4G) to RF module 1800 FXEF 1 Optical cable OPT Port 1
SRAN FSM-FR4
From FSMF of LTE (4G) to RF module 1800 FXEF 2 Optical cable OPT Port 1
Qty
2 2 2 2
Label to be prepared for Optical Cable of 2G 1800 from BLANK Labels Lable Text
Location
FSM-FR3 -OPT 2
From FSMF of GSM (2G) to RF module 1800 FXEF 1 Optical cable OPT Port 1
FSM-FR4 -OPT 2
From FSMF of GSM (2G) to RF module 1800 FXEF 2 Optical cable OPT Port 2
Labeling instructions for Transmission Cable :Labeling on Transmission Cable Location
Lable Text SRAN FSM-TX
Qty
From Transmission Router/Mux Ethernet to System Module of LTE ( 4G )
2
Label to be prepared for Transmission Cable of 2G from Blank Labels Lable Text
Location
FSM- 2G TX 1
From Tx DDF to System Module of GSM ( 2G )- 1st E1
FSM- 2G TX 2
From Tx DDF to System Module of GSM ( 2G )- 2nd E1
FSM- 2G TX 3
From Tx DDF to System Module of GSM ( 2G )- 3rd E1
Qty
2 2 2
Labeling instructions for Power Cables of RF Modules :Labeling on Power Cable of RF Module 900 FXJB - FR1 Location
Lable Text SRAN FR1-PP
From FSES ( OVP ) to RF module 900 FXJB - AT module end
SRAN FR1-PP
From DCDB to FSES ( OVP ) - At FSES (OVP) End
SRAN FR1-PP
On +ve Cable - At Positive Bus Bar in DCDB
SRAN FR1-PP
On -ve Cable - At MCB End
Qty Total Qty
1 1 1 1
4
Labeling on Power Cable of RF Module 2100 FRGU - FR2 Location
Lable Text SRAN FR2-PP
From FSES ( OVP ) to RF module 2100 FRGU - AT module end
SRAN FR2-PP
From DCDB to FSES ( OVP ) - At FSES (OVP) End
SRAN FR2-PP
On +ve Cable - At Positive Bus Bar in DCDB
SRAN FR2-PP
On -ve Cable - At MCB End
Qty Total Qty
1 1 1 1
4
Labeling on Power Cable of RF Module 1800 FXEF 1 - FR3 Location
Lable Text SRAN FR3-PP
From FSES ( OVP ) to RF module 1800 FXEF 1 - AT module end
SRAN FR3-PP
From DCDB to FSES ( OVP ) - At FSES (OVP) End
SRAN FR3-PP
On +ve Cable - At Positive Bus Bar in DCDB
SRAN FR3-PP
On -ve Cable - At MCB End
Qty Total Qty
1 1 1 1
4
Labeling on Power Cable of RF Module 1800 FXEF 2 -FR4 Location
Lable Text SRAN FR4-PP
From FSES ( OVP ) to RF module 1800 FXEF 2 - AT module end
SRAN FR4-PP
From DCDB to FSES ( OVP ) - At FSES (OVP) End
SRAN FR4-PP
On +ve Cable - At Positive Bus Bar in DCDB
SRAN FR4-PP
On -ve Cable - At MCB End
Qty Total Qty
1 1 1 1
4
Labeling instructions for Power Cables of System Modules :Labeling to be prepared for Power Cables of 2G , 3G and LTE System Module from Blank Location Lable Text Qty Total Qty FSM-2G-PP From DCDB to 2G system Module - AT module end 1 FSM-3G-PP From DCDB to 3G system Module - AT module end 3 1 FSM-LTE-PP From DCDB to LTE system Module - AT module end 1
Labeling instructions for Main Power Cables from Power Plant to DCDB :Labeling on Power Cable of DCDB from Power Plant Lable Text
Location
SRAN FSM-PP
On Main +ve Cable from Power Plant to DCDB
SRAN FSM-PP
On Main -ve Cable from Power Plant to DCDB
Qty Total Qty
2 2
4
Labeling instructions for Grounding Cables of RF Modules :Labeling on Grounding Cable of RF Modules Lable Text