Chapter 7 Evaluation of Paracetamol Tablets EVALUATION OF PARACETAMOL TABLETS Almost all Pharmacopoeias include some suitable standards and tests to ensure the quality of tablets. The standards an...Full description
Full description
The Tell Amarna Tablets Translated by C. R. Conder 2nd Ed. (1894)
Full description
Guide to Fill up AT Tablet Using Siteforge RJIL Project (India)
AT Assessments:
Adonis M. Amparo
Sr. Systems Engineer Ceragon Networks
September 2014
Background: Completion of site data, commissioning information and supporting photos during AT is the first step for the customer to evaluate the link acceptance. It is necessary that all information satisfies the quality requirement of customer CTO to proceed with site verification and approval of each link.
Cause of the Problem: Although field engineers have configured and prepared the link for acceptance, some of the necessary information captured in AT tablets don’t satisfy the requirement of AT document. Quality engineers have to verify correct data and capture the necessary information again. Some of them requires multiple visit to the site resulting to delay of AT submission and longer turnaround time of project completion. 2
Proprietary and Confidential
Requirements: - Updated Link Budget Summary (LB tracker) - Updated DCN Plan - Updated/Latest QOS information
Important Reminders: 1. It is recommended that 2 sites ATP (1 Hop) need to be done from same TAB. Don't use 2 different TABs for same hop. 2. ATP for 1 hop need to be completed by single team and on same day to avoid data mismatch and loss. 3. Team to check software version of site forge in TAB (Need latest version, otherwise team need to upgrade the 4. Planned site information in the tablet are auto populated. Any deviation needs to be verified and reported in the remarks box. 5. All quality requirements must be satisfied. 6. Current alarms should be cleared before AT. Proprietary and Confidential
How to Complete AT Data using Tablet
Proprietary and Confidential
1. Open “Siteforge-Microwave” icon.
Siteforge software should be installed in the tablet Proprietary and Confidential
2. Fill in appropriate account login
Notes: - Team need to login into TAB with internet access before visiting site for ATP (Site will be downloaded once FE login's) - Use ATP engineer login for doing ATP on site. Account will be provided by RJIL . Proprietary and Confidential
3. Select the site for AT AT Status: AT completed by Field Engineers/For Review Ongoing Review Review Completed/ Submitted
Proprietary and Confidential
4. Perform Task
Start checking AT/Perform Task * Note which site you are working. Either Site A or Site B to identify correct data from the LB tracker and DCN plan. Site A Site B
Proprietary and Confidential
5. Review of Page 1 (Links Details) Shows the site you are working Fill the actual Tower Type and choose “Yes”. Compare the actual data from the planned data.(see next page) Coordinates is the actual latitude/longitude value captured at the field. Do not capture if you are in another place. Make sure to compare from the planned data. Proprietary and Confidential
5. Review of Page 1 (Con’t)
Choices of Tower Type. Fill out with actual tower at the site. If there is mismatch in actual and planned data, mention the same in remark.
Proprietary and Confidential
5. Review of Page 1 (Con’t)
Check actual building height Verify radio link configuration from the LB. Choose “1+0” or “XPIC” (for 2+0) configuration. Verify OFC take off point from the LB. Choose “AG1” or “CSS” After completing page 1. Click “Save” button. And “Next” to go to page 2. Proprietary and Confidential
5. Review of Page 2 (Antenna Details)
Verify actual antenna size from the LB tracker Scanned barcode of the antenna
Verify actual height of antenna from the ground. It will be the height of the antenna from the pole + the height of the building for RTP/RTT/RTD.
Proprietary and Confidential
5. Review of Page 2 (Cont’n) OK – if antenna is installed with pole mount. N/A - if antenna is installed directly to the pole (RTP) or tower leg (RTD/RTT) without using pole mount Mention same in remark field as well. Choose “OK” “NA” for antenna size 0.3m and 0.6m Click “Save” button. And “Next” to go to page 3. Proprietary and Confidential
5. Review of Page 3 (ODU Mount) Should be “Yes”
Should be “Yes”
Should be “Yes”
Check port 2 since we use ETH2 port of the RFU. Click “Save” button. And “Next” to go to page 4. Proprietary and Confidential
5. Review of Page 4 (Traffic Cable) Fill the actual fiber cable length installed in the site.
Available cable length supplied by Ceragon. Actual length depending on the site request.
Proprietary and Confidential
5. Review of Page 4 (Cont’n)
Should be “Yes”
Should be “Yes”
Should be “Yes”
Proprietary and Confidential
5. Review of Page 4 (Cont’n)
Choose the correct traffic cable type used at the site.
Click “Save” button. And “Next” to go to page 5. Proprietary and Confidential
5. Review of Page 5 (Labeling)
Should be “Yes”
Should be “Yes” Should be “Yes” Should be “Yes”
Proprietary and Confidential
5. Review of Page 5 (Cont’n)
Should be “Yes” Should be “Yes” Should be “Yes” Should be “Yes” Click “Save” button. And “Next” to go to page 5. Proprietary and Confidential
5. Review of Page 6 (Power Cable) Fill out with actual length of DC cable.
RJIL uses Outdoor DC cable. Select “DC” type of power supply Type the actual DC voltage from the supply. Should be negative (-) and same value with site photo. Should be “Yes” Proprietary and Confidential
5. Review of Page 6 (Cont’n) Select actual MCB rating used. Recommended is 6A MCB otherwise fill out the box for remarks.
MCB Rating (6A) Proprietary and Confidential
5. Review of Page 7 (Commissioning) Check ODU model from the link budget and compare to the actual installation. Should match. Type actual S/N of ODU Verify actual software version of the ODU. Should be 7.7.5.0.0.68
Verify that Tx Frequency is according to LB otherwise request to revise LB. Proprietary and Confidential
5. Review of Page 7 (Cont’n) Verify that polarization is according to LB. Verify that Rx frequency is according to LB. Verify that Tx Power is according to LB. Verify that RSL satisfies the acceptable RSL vs LB, ATPC should be “NO” or according to LB design, Proprietary and Confidential
5. Review of Page 7 (Cont’n) Should be “Yes” and supported by photo. Should be “Yes” and supported by photo. Should be “Yes” and supported by photo. Should be “Yes” and supported by photo. Should be “N/A” as per RJIL configuration Click “Save” button. And “Next” to go to page 8. Proprietary and Confidential
5. Review of Page 8 (Management Configuration) Type the correct IP address according to DCN plan Type the correct Subnet Mask according to DCN plan
Type “N/A” if IP plan is not according to IPv6. Type “N/A” if IP plan is not according to IPv6. Type the correct Default Gateway value according to DCN plan Should be “Yes”. Proprietary and Confidential
5. Review of Page 8 (Cont’n) Should be “Yes” and supported by photo. Type the correct VLAN ID of In band Management according to DCN plan. Should match with photo. Should be “Yes”. Type the correct CSS/AG1 port according to DCN plan. Should match with labels Proprietary and Confidential
5. Review of Page 8 (Other Parameters) Should be “Yes” and supported by photo of current alarms. Site should be free from any alarm. Should be “Yes”.
Click “Save” button. And “Next” to go to page 9. Proprietary and Confidential
Site Photos
Link Details
Proprietary and Confidential
Site Coordinates
Site Coordinate taken from GPS Site coordinate photo will ne N/A.GPS use is optional since AT tablets can capture the actual latitude and longitude from the page 1 of the folder. Proprietary and Confidential
Site Name
Type the NE ID (not the SAP ID) Fill with Name of Contact Person SAP ID + Site Name Site Coordinates. Actual Longitude and Latitude value. Proprietary and Confidential
Antenna Details
Proprietary and Confidential
Antenna Installation in Pole Mount/Pole
Ensure that bolts and nuts are properly tightened and complete Proprietary and Confidential
Antenna make and Model
Antenna information should be readable Proprietary and Confidential
Antenna Strut Availability for size >= 1.2M
“NA” for antenna size 0.3m and 0.6m Proprietary and Confidential
Azimuth on GPS
Azimuth is autopopulated in AT tablets Proprietary and Confidential
Pole Mount Installation at tower
or
“NA” for antenna installation without pole mount.
Take picture of whole pole mount Proprietary and Confidential
ODU Mount
All photo of flexible waveguide will be “NA” Proprietary and Confidential
Grounding
Grounding cables should be properly terminated and groomed Proprietary and Confidential
ODU Mount
Left and right photo of ODU mounting with antenna should be on opposite sides. Proprietary and Confidential
ODU Mount
All photo of flexible waveguide will be “NA” Proprietary and Confidential
Traffic Cables
Proprietary and Confidential
Cable Connection with ODU
Cables are groomed properly with cables tied to the gland Proprietary and Confidential
Weather proofed at ODU
Glands are properly tightened Proprietary and Confidential
Cable tied at regular interval
Cables are tied together properly with cable ties in regular interval not greater than 1.5m Proprietary and Confidential
Labeling
Labeling should be according to standard and should be readable Proprietary and Confidential
Labeling
Labeling should be according to standard and should be readable Proprietary and Confidential
Polarization marking of ODU
ODU polarization should be according to LB and commissioning parameters Proprietary and Confidential
Printed labeling of XPIC
XPIC label should be “NA” for 1+0 links
XPIC label should reflect horizontal and vertical polarization for 2+0 links
Proprietary and Confidential
Power cable
Proprietary and Confidential
Measured DC Voltage input to the ODU
Measured DC voltage should be in negative value (-) Proprietary and Confidential
ODU DC connection
Photo of DC connection should be taken at ODU portion and not at the MCB connection side. Proprietary and Confidential
Commissioning
Proprietary and Confidential
Current Modulation
Make sure to capture the Current Modulation at its maximum modulation profile. Photo should not be the MRMC configuration Proprietary and Confidential
QOS Profile
Sample of Qos Configuration Note: Follow the Policer profile according to link configuration. Proprietary and Confidential
QOS Profile
Qos profile of 1+0
Follow the Policer profile according to link configuration. Proprietary and Confidential
QOS Profile
Qos profile of 2+0, XPIC Follow the Policer profile according to link configuration. Proprietary and Confidential
RSL
Verify that RSL is within the acceptable level according to the LB Proprietary and Confidential
Rx Frequency
Verify that Rx frequency is according to the LB Proprietary and Confidential
Tx Power
Verify that Tx Power is according to the LB Proprietary and Confidential
Tx Frequency
Verify that Tx Frequency is according to the LB Proprietary and Confidential
Management Configuration
Proprietary and Confidential
IP Address
IP address details should follow IP plan and supports IPv6. Proprietary and Confidential
SNMP Configuration
Admin: Enable
SNMP Trap Version: V2
Proprietary and Confidential
VLAN ID for Inband Management
VLAN ID should be according to the DCN plan Proprietary and Confidential
Other Parameters
Site should be clear from any current alarm. Proprietary and Confidential
Recommendation: 1. It is recommended to save all the commissioning
2. 3. 4.
parameters in the laptop by taking screen capture of each page for future reference. Take extra photos and save to laptop. Check that all photos are visible and readable. Review that all parameters and pictures are in accordance with the plan before leaving the site.