Installing Flexi Syste tem m External Alarm (FSEB)
Installing Flexi Multiradio Base Sta tattion and Flexi Multiradio 10 Base Station Optional Items
18 Installing Flexi System External Alarm (FSEB) 18.1 Installing Flexi System External Alarm (FSEB) These instructions show how install and connect the cabling of Flexi System External Alarm (FSEB). (FSEB). Before you start Flexi System External Alarm (FSEB) 471424A can be installed either horizontally (cable lead-ins on the side) or vertically (cable lead-ins facing downwards, or left or right). See the following figures for the two installation options. Figure 290
244
FSEB installed horizontally
DN09142359
Issue: 04
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Figure 291
Installing Flexi System External Alarm (FSEB)
FSEB installed vertically
In outdoor installations, the cable lead-ins must be facing downwards, left or right to meet the IP55 standard. Figure 292 FSEB connectors
ESD
Grounding point EAC M16 UltraSite and Talk swap cases BTS interconnection cable
Issue: 04
DN09142359
245
Installing Flexi System External Alarm (FSEB)
Figure 293
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Fixing FSEB cables
) . m n x i a m . 0 7 m 0 9 5 1 (
Cable fixing
When the cable is routed down, tie the cable a maximum of 500 mm (19.7 in) away from the FSEB to prevent the weight of the cable to break the cable lead glands of the FSEB. Before installing the FSEB, see FSEB interface signals and connector pin assignments. In pole or wall installations, locate the box in the proximity of the System Module. In wall installations, make sure that the mounting surface is flat. The distance from the FSEB to the System Module is limited by the length of the alarm cable. If using Flexi Mounting Auxiliary Brackets (FMAA), see the following figures for the installation position of the FSEB on the module casing.
246
DN09142359
Issue: 04
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Figure 294
Installing Flexi System External Alarm (FSEB)
FMAA with FSEB
FMAA
FMAA
FSEB
FSEB
Figure 295 FMAA with FSEB and FSEC
FMAA
FMAA FSEB
FSEB FMAA FSEC FSEC
In FCIA and FCOA installations, use the fixing points on the cabinet roof.
Issue: 04
DN09142359
247
Installing Flexi System External Alarm (FSEB)
Figure 296
248
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
FSEB fixing points on the FCIA roof
DN09142359
Issue: 04
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Installing Flexi System External Alarm (FSEB)
Figure 297 FSEB fixing points on the FCOA roof 1.
2.
3.
w
NOTICE: Electrostatic discharge (ESD) might damage the equipment. Wear an ESD wrist strap when handling the external alarm connection box. When connecting the cables, make sure that the cable lead-ins that are not used are blocked. A module ground cable is not included in the FSEB delivery. The minimum cross-section of the cable should be 2.5 mm2 (14 AWG). The length of the cable should be determined based on the FSEB installation option (for example pole, wall, cabinet, or third-party cabinet).
Issue: 04
DN09142359
249
Installing Flexi System External Alarm (FSEB)
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Procedure
1
Install the FSEB with four M5 screws using the fixing holes in the bottom of the box. Figure 298
Install FSEB with four M5 screws
Note that you do not need to open the box to install it. In stack, wall or pole installation, install the FSEB using the mounting brackets. See Installing Flexi Mounting Auxiliary Brackets (FMAA) for installation instructions.
2
Ground the box using the grounding screw on the right side of the FSEB front plate. Fix the nut tightly.
250
DN09142359
Issue: 04
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Figure 299
Installing Flexi System External Alarm (FSEB)
Connect the grounding cable
3
2
3
Connect the ESD wrist strap first to your wrist and then to the grounding clip next to the grounding screw.
4
Open the lid of the FSEB box. If using 12 alarms, set jumper X1103 to 12 Alarms mode. If using 24 alarms, set the jumper to 24 Alarms mode. Figure 300 Jumper X1103 in 12 Alarms mode
12 Alarms 24 Alarms
See Table 9: Alarms supported by System Module variants for the number of supported alarms per technology.
Issue: 04
DN09142359
251
Installing Flexi System External Alarm (FSEB)
Table 9
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Alarms supported by System Module variants
System Module variant
Alarms supported
Requirements
ESMA, ESMB, ESMC
24
N/A
FSMC, FSMD, FSME (WCDMA)
24
FSEB v.304
FSMD, FSME (LTE)
12
N/A
FSMF (WCDMA)
24
FSEB v.304
WN6.0 MP3 or later
WN7.0 2.0 or later
252
FSMF (LTE)
12
N/A
FSMF (GSM/EDGE)
12
N/A
DN09142359
Issue: 04
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
5
Installing Flexi System External Alarm (FSEB)
Connect the external alarms cable (included in the FSEB delivery) from the FSEB to the System Module. Figure 301
Connect the external alarms cable
5
a) Pull the left U-shaped cable gland from the FSEB box. b) Remove the hole closing plug from the cable gland. If the plug is fixed with a cable tie, cut the cable tie first and remove it. c) Insert the cable in the cable gland. The D-Sub plug must point to the inside of the box. d) Connect the D-Sub plug to the leftmost D-Sub connector X1101 (ESM) on the FSEB board. e) Fix the connector fixing screws. f) Insert the U-shaped cable gland to the front plate. g) Insert the cable to the round rubber-seal in front of the U-shaped cable gland. h) Fix the cable with a cable tie. Make sure that the U-gland fixes the cable tightly. The cable must not move inside the gland. i) Route the cable between the FSEB and System Module and fix it with cable ties. The first fixing point must not be further away from the FSEB box than 0.5 m (1.6 ft).
Issue: 04
DN09142359
253
Installing Flexi System External Alarm (FSEB)
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
j) Remove the cover of the EAC connector on the System Module. k) Insert the other end of the cable with the MDR-36 (FTSJ) or HDMI (FTSI) connector to the EAC connector of the System Module. Make sure that the connector is firmly in place. l) Push the connector cover over the cable connector and seal the EAC connector at the System Module with this cover.
6
t
If you are using an existing alarm cable (cable diameter min. 4-6 mm, ovality 1 mm) with a 37-pole D-Sub connector, connect the cable with a D-Sub connector as follows: Tip: These two alarm cables can be connected to the EACX-I and EACX-II connectors of the FSEB, respectively. Connect the BTS alarm cables 1-12 and 13-24 to EACX-I and EACX-II connectors. Note that signals ext_al 13...24 are considered in BTS commissioning and fault handling as external alarms with IDs from 15 to 26. Pay attention to connect them to the right EACX connector, otherwise the alarm number and alarm description will not match. After the installation, trigger and verify the alarm condition using the BTS Site Manager. a) b) c) d)
Pull the right U-shaped cable gland from the FSEB box. Cut the cable tie off the cable gland. Remove the hole closing plug from the cable gland. Insert the alarm cable in the cable gland. The D-Sub plug must point to the inside of the box. e) Attach the D-Sub plug to the right 37-pole D-Sub connector X4101 (EACX-I port). f) Fix the connector fixing screws. g) Insert the U-shape cable gland to the front plate. h) Insert the cable to the round rubber-seal in front of the U-shaped cable gland. i) Fix the cable with a cable tie. Make sure that the U-gland fixes the cable tightly. The cable must not move inside the gland. j) Route the cable and fix it with cable ties. The first fixing point must not be further away from the FSEB box than 0.5 m (1.6 ft).
7
If you are using the separate alarm cables, connect them to the screw terminals as follows: a) Tighten the cable gland nut. The cable must not move inside the gland. b) Insert the alarm cables in the FSEB box by using the cable glands on the rightside half of the FSEB box. c) Route the alarm cables and fix them with cable ties. The first fixing point must not be further away from the FSEB box than 0.5 m (1.6 ft). d) Attach alarm lines EXT_AL1 to EXT_AL12 using screw terminal blocks X4106X4109.
254
DN09142359
Issue: 04
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Installing Flexi System External Alarm (FSEB)
e) For each alarm input, connect one wire to the GROUND screw terminal blocks X4107 or X4109 and connect one wire to t he selected alarm input on screw terminal blocks X4106 or X4108. The alarm inputs are marked on the FSEB board with 'EXT_AL6 ... EXT_AL1' on X4106 and 'EXT_AL12 ... EXT_AL7' on X4108.
t
8
Tip: If you use alarm inputs on the EACX-I port (D-Sub connector X4101), do not use the same alarm inputs on the screw terminals X4106 and X4108.
If you are using the control output cables, connect them as follows: a) Tighten the cable gland nut. The cable must not move inside the gland. b) Insert the control output cables in the FSEB box by using the cable glands on the right-side half of the box. c) Route the control cables and fix them with cable ties. The first fixing point must not be further away from the FSEB box than 0.5 m (1.6 ft). d) Attach the control lines EXT_CO1 to EXT_CO6 by using the screw terminal blocks X4104 and X4105. e) Control outputs are open collector type. Connect a pull-up resistor (2-6 kilohms, 5 kilohms is recommended) or an optocoupler to +5 V to ensure correct operation. The control outputs are marked on the FSEB board with 'EXT_CO6 ... EXT_CO1' on X4104.
Issue: 04
DN09142359
255
Installing Flexi System External Alarm (FSEB)
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Figure 302 Control outputs FSEB / System Module
PS
+5V
OCP
RPullUp 2...6kOhm 600 ohm
To customer application
OVP
EXT_CO1...EXTCO6 (Pins 1...6)
CTRL EAXC I EAC
FSEB / System Module
PS
+5V
OCP
Optocoupler
To customer application ~160 ohm OVP
EXT_CO1...EXTCO6 (Pins 1...6)
CTRL EAXC I EAC
g
Note: If galvanic isolation is required for the customer application, see the figure above for an example with an optocoupler. Follow the country-specific safety requirements.
t
Tip: If you use control outputs on the EACX-I port (D-Sub connector X4101), do not use the same control outputs on the screw terminal X4104.
9
Install the fire detector to the FSEB (optional). a) Connect the fire detector to the FSEB using a four-wire cable. Two wires are needed for fire detector power supply and two for the fire detector alarm connection. b) Attach the four wires of the cable to the fire detector relay-base. c) Insert the other end of the four wire cable through one cable gland at the right half of the FSEB box.
256
DN09142359
Issue: 04
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Installing Flexi System External Alarm (FSEB)
d) Tighten the cable gland nut. The cable must not move inside the gland. e) Route the cable and fix it with cable ties. The first fixing point must not be further away from the FSEB box than 0.5 m (1.6 ft). f) Attach the wire marked with + from the fire detector to the leftmost or rightmost opening of the screw terminal X4114. g) Attach the wire marked with - from the fire detector to one of the four middle openings of the screw terminal X4114 marked with GND. See Fire detector power supply interface in FSEB interface signals and connector pin assignments. h) Attach the fire detector alarm wires to one of the alarm inputs 'EXT_AL12 ... EXT_AL1'.
10 Install the cover of the FSEB box and tighten the eight screws to 1.7 Nm (1.25 ft-lb.). Figure 303
Issue: 04
Install the cover
DN09142359
257
Installing Flexi System External Alarm (FSEB)
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
18.2 FSEB interface signals and connector pin assignments Figure 304
FSEB printed wiring board EACX-II Connector
ESM Connector
Fire Detector Power Supply output
EACX-I Connector
Alarm Inputs
Control Outputs
5V EAC Output
Ground Connections
EACX connector I pin assignment Table 10
Pin
258
EACX connector I pin assignment (Sub-D37)
Signal
Pin
Signal
1
EXT_CO1
19
GND
2
EXT_CO2
20
+5V/30mA
3
EXT_CO3
21
+5V/30mA
4
EXT_CO4
22
+5V/30mA
5
EXT_CO5
23
+5V/30mA
6
EXT_CO6
24
+5V/30mA
7
EXT_AL1
25
+5V/30mA
8
EXT_AL2
26
GND
9
EXT_AL3
27
GND
DN09142359
Issue: 04
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Table 10
Installing Flexi System External Alarm (FSEB)
EACX connector I pin assignment (Sub-D37) (Cont.)
Pin
Signal
Pin
Signal
10
EXT_AL4
28
GND
11
EXT_AL5
29
GND
12
EXT_AL6
30
GND
13
EXT_AL7
31
GND
14
EXT_AL8
32
GND
15
EXT_AL9
33
GND
16
EXT_AL10
34
GND
17
EXT_AL11
35
GND
18
EXT_AL12
36
GND
-
-
37
GND
EACX connector II pin assignment EACX connector II is not used in the 12 Alarms mode. Note that signals ext_al 13...24 are considered in BTS commissioning and fault handling as external alarms with IDs from 15 to 26. Table 11
Pin
Issue: 04
EACX connector II pin assignment (Sub-D37)
Signal
Pin
Signal
1
EXT_AL13
19
GND
2
EXT_AL14
20
GND
3
EXT_AL15
21
GND
4
EXT_AL16
22
GND
5
EXT_AL17
23
GND
6
EXT_AL18
24
GND
7
EXT_AL19
25
GND
8
EXT_AL20
26
GND
DN09142359
259
Installing Flexi System External Alarm (FSEB)
Table 11
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
EACX connector II pin assignment (Sub-D37) (Cont.)
Pin
Signal
Pin
Signal
9
EXT_AL21
27
GND
10
EXT_AL22
28
GND
11
EXT_AL23
29
GND
12
EXT_AL24
30
GND
13
Not used
31
Not used
14
Not used
32
Not used
15
Not used
33
Not used
16
Not used
34
Not used
17
Not used
35
Not used
18
Not used
36
Not used
-
-
37
Not used
Screw terminal pin assignment Table 12
260
Screw terminal pin assignment
Signal
Screw terminal
Signal
EXT_CO1
Connector X4104 pin 1
+5V
Connector X4105 pin 1
EXT_CO2
Connector X4104 pin 2
+5V
Connector X4105 pin 2
EXT_CO3
Connector X4104 pin 3
+5V
Connector X4105 pin 3
EXT_CO4
Connector X4104 pin 4
+5V
Connector X4105 pin 4
EXT_CO5
Connector X4104 pin 5
+5V
Connector X4105 pin 5
EXT_CO6
Connector X4104 pin 6
+5V
Connector X4105 pin 6
DN09142359
Screw terminal1)
Issue: 04
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Table 12
Signal
Issue: 04
Installing Flexi System External Alarm (FSEB)
Screw terminal pin assignment (Cont.)
Screw terminal
Signal
Screw terminal1)
EXT_AL1
Connector X4106 pin 1
GND
Connector X4107 pin 1
EXT_AL2
Connector X4106 pin 2
GND
Connector X4107 pin 2
EXT_AL3
Connector X4106 pin 3
GND
Connector X4107 pin 3
EXT_AL4
Connector X4106 pin 4
GND
Connector X4107 pin 4
EXT_AL5
Connector X4106 pin 5
GND
Connector X4107 pin 5
EXT_AL6
Connector X4106 pin 6
GND
Connector X4107 pin 6
EXT_AL7
Connector X4108 pin 1
GND
Connector X4109 pin 1
EXT_AL8
Connector X4108 pin 2
GND
Connector X4109 pin 2
EXT_AL9
Connector X4108 pin 3
GND
Connector X4109 pin 3
EXT_AL10
Connector X4108 pin 4
GND
Connector X4109 pin 4
EXT_AL11
Connector X4108 pin 5
GND
Connector X4109 pin 5
EXT_AL12
Connector X4108 pin 6
GND
Connector X4109 pin 6
EXT_AL13
Connector X4110 pin 1
GND
Connector X4111 pin 1
EXT_AL14
Connector X4110 pin 2
GND
Connector X4111 pin 2
EXT_AL15
Connector X4110 pin 3
GND
Connector X4111 pin 3
EXT_AL16
Connector X4110 pin 4
GND
Connector X4111 pin 4
DN09142359
261
Installing Flexi System External Alarm (FSEB)
Table 12
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Screw terminal pin assignment (Cont.)
Signal
Screw terminal
Signal
Screw terminal1)
EXT_AL17
Connector X4110 pin 5
GND
Connector X4111 pin 5
EXT_AL18
Connector X4110 pin 6
GND
Connector X4111 pin 6
EXT_AL19
Connector X4112 pin 1
GND
Connector X4113 pin 1
EXT_AL20
Connector X4112 pin 2
GND
Connector X4113 pin 2
EXT_AL21
Connector X4112 pin 3
GND
Connector X4113 pin 3
EXT_AL22
Connector X4112 pin 4
GND
Connector X4113 pin 4
EXT_AL23
Connector X4112 pin 5
GND
Connector X4113 pin 5
EXT_AL24
Connector X4112 pin 6
GND
Connector X4113 pin 6
1)
The X connectors are marked on the bottom of the FSEB PCB.
Fire detector power supply interface Table 13
Pin
262
Fire detector power screw terminal X4114 pin assignment
Signal
1
+8.55V ... +11.5V
2
Ground
3
Ground
4
Ground
5
Ground
6
+8.55V ... +11.5V
DN09142359
Issue: 04
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
Installing Flexi System External Alarm (FSEB)
18.3 EAC cable (FTSI 472578A) wiring Table 14
EAC cable (FTSI) wiring
Conn. 1 (HDMI) Conn. 2 (D37)
Issue: 04
Pair: wire color
Description
Pin no.
Pin no.
1
7
1: Black
EXT_AL0_H
2
8
2: Brown
EXT_AL1_H
3
9
1: White/Black
EXT_AL2_H
4
10
2: White/ Brown
EXT_AL3_H
5
11
3: Red
EXT_AL4_H
6
12
4: Orange
EXT_AL5_H
7
1 + 13
3: White/Red
EXT_CTRL0_EXT_AL 6_H
8
2 + 14
4: White/Orange
EXT_CTRL1_EXT_AL 7_H
9
3 + 15
5: Yellow
EXT_CTRL2_EXT_AL 8_H
10
4 + 16
6: Green
EXT_CTRL3_EXT_AL 9_H
11
5 + 17
5: White/Yellow
EXT_CTRL4_EXT_AL 10_H
12
6 + 18
6: White/Green
EXT_CTRL5_EXT_AL 11_H
13
19
7: Blue
P5V0_EAC
14
20
7: White/Blue
P5V0_EAC
15
23
8: Violet
PROT_CAN_H_P5V_ EAC
16
27
9: Grey
GND
17
24
8: White/Violet
PROT_CAN_L_P5V_ EAC
18
25
10: Pink
GND
DN09142359
263
Installing Flexi System External Alarm (FSEB)
Table 14
Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional Items
EAC cable (FTSI) wiring (Cont.)
Conn. 1 (HDMI) Conn. 2 (D37)
264
Pin no.
Pin no.
19
28
Pair: wire color
Description
9: White/Grey
GND
DN09142359
Issue: 04