The Science of Compressed Air
QUINCY AIR SYSTEMS FILTERS COALESCERS ABSORBERS ELEMENTS
C O M P R E S S E D A I R F I LT E R S Quincy Filters protect pneumatic equipment and processes from the harmful effects of contaminated compressed air by removing dirty water, burnt oil and solid pollutants before they can do any damage. Clean compressed air will result in improved production and reduced operating costs. World class, state-of-the-art material and design make Quincy Compressed Air Filters the standard to which all others must be compared.
STANDARD FILTERS
BREATHABLE AIR SYSTEMS
Particu late — Coalescer — Absorber
FOR PAINT OR SANDBLAST
Our Standard Filtration lineup consists of the three most common types of filters used in compressed air systems.
APPLICATIONS
THE QUINCY DCN SERIES
Particulate/Coarse Coalescer is designed to remove solids, burnt oil and bulk liquids. THE CSN, CPN, CXN SERIES
Coalescers remove various levels of liquid aerosols and mist. THE ACN SERIES
Activated C arbon Absorbers remove vapors and odors. •
10 scfm to 16,500 scfm
•
230 psig max. worki ng press ure for threaded filters
•
150 psig max. worki ng press ure for flanged filters
•
1 Al umi nu m ho usi ng ( ⁄ 2" to 3" NPT)
•
Steel ho usi ng (3" to 12" FLG)
(Will not remove certain types of gases, including CO or CO2 ) •
15 cfm two-port ma nifold
•
30 scfm, fo ur-port ma nifold
•
230 psig max. worki n g press u re
•
Floor stand or wallmo un ti n g brackets
•
Air press ure reg ulator
•
Air press ure ga uge
•
Available air heater
HIGH-TEMPERATURE DUST FILTER • +450°F/150 psig • 15 to 1600 scfm
MOISTURE SEPARATORS •
20 to 1500 scfm, 230 psig
•
1 4" to 3" NPT) Al umi nu m ho usi ng ( ⁄
OVER & UNDER COALESCER/ABSORBER COMBINATION •
10 to 50 scfm/230 psig
•
Two-in-o ne desig n
QuincyCompressor.com 2
|
Mad e in the U.S.A. |
The Science of Compressed Air
The Science of Air Treatment
ELEMENTS
Quincy’s Layered Multiwrap design employs a specially blended borosilicate glass microfiber media to produce strong, durable and efficient filter elements. The filtration media combines high flow rates and high dirt-holding capacities without compromising element service life. Easy to identify and easy to install, these highly advanced products offer the best performance available
ELEMENT CONSTRUCTION
Push-to-Fit Design — Aluminum Filters
Polyester Needle Felt Drainage Layer
•
Easy element replaceme n t
•
Optim um oil removal
•
Fit i ntegrity elimi nates leaks, savin g e nergy
•
High temperat ure tolera nce
•
Maximum d urability
•
Will not disintegrate
•
Su itable for u se with mi neral a nd s ynthetic oils
•
Tolera nt i n aggressive enviro n me nts
Stainless Steel Support Core •
Provides stren gth
•
Elimin ates corrosion
•
Protects eleme nt from bu rsting un der high differe n tial press ure
1st Stage Pre-Filtration Support Layer •
Capt ures larger co n tami nates
•
Protects 2nd Stage filtratio n media
•
Exten ds service life
Glass-Filled Nylon End Caps •
Color-coded for simple eleme nt grade ide ntification
•
Easy elemen t replaceme nt
•
Will not corrode
Multiwrap 2nd Stage •
High void vol ume mi nimizes press u re drop, savi ng e n ergy
•
Increased s urface area e nsures maximum c ontami n ant rete ntio n
•
Extended life co n str uction
•
Deep bed provides optim um coalescin g efficie ncy
•
Selected media combi nation s provide precise filtratio n sol utio n s
3rd Stage Interceptor Layer •
Provides additio nal strength
•
Optimizes i nterceptio n process
4th Stage Outer Stainless Steel Support •
En sures total eleme n t i ntegrity
Inside to Out Flow •
Prolo ngs eleme nt life a nd improves drai n performan ce
3
C O M P R E S S E D A I R F I LT E R S STANDARD LINE — PARTICULATE – COALESCER – ABSORBER
Quincy’s Standard Filtration lineup consists of the three most common types of filters used in compressed air systems. Aluminum housings with threaded NPT connections are used for flows up to 1530 cfm and steel housings with flanged connections are used for flows up to 16,500 cfm. •
Push-to-fit design used on threaded filters for easy filter element replacement
•
Multiwrap eleme nt co nstr uction ensures optimum performa nce
•
Modular design saves energy and allows for easy installation of m ultiple threaded filters
•
Aluminum ho usings feature electrophoretic coati ng to prevent corrosion
•
10-year housing g uarantee on aluminum ho usings
•
Standard press ure differe ntial indicator
•
Standard automatic condensate drain
ALUMINUM HOUSINGS, THREADED CONNECTIONS 10 TO 1530 CFM DCNT SERIES •
CSNT, CPNT, CXNT SERIES
Desig n ed to remove high co n ce n tratio n s of solids, b u r n t oil a n d b u lk li qu id s DCNT 5 micro n , 5 ppm
•
Design ed to coalesce vario u s levels of li qu id aerosols. Th e 1 micro n CSN is also a n ideal afterfilter for desicca n t dryers. CSNT 1 micro n , 0.1 ppm CPNT .01 micro n , .01 ppm CXNT .01 micro n , .001 ppm
ACNT SERIES •
Activated Carbo n Absorber desig n ed to remove vapors a n d odors. I n stalled immediately dow n stream of either a CPNT or a CXNT coalescer, it will red u ce oil carryover to .003 ppm.
STEEL HOUSINGS, FLANGED CONNECTIONS 1500 TO 16,000 CFM SERIES DCNF, CSNF, CPNF, CXNF AND ACNF •
Same filtration grade as al uminum filters
•
Identified with a n “F” suffix
•
U stamped for the USA a nd CRN approved for Ca nada
•
Housings are freesta nding a nd top loadi ng for easy eleme nt replacement
•
All grades of filter eleme nt end caps are molded, providi ng strength, durability and lo ng life
QuincyCompressor.com 4
|
Mad e in the U.S.A. |
The Science of Compressed Air
The Science of Compresse d Air
STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA
Complete Filter Assemblies Filter Model Pipe Size Flow Rate (Grade) NPT scfm Nm3/hr
Grade 10 Grade 20 Grade 30 Grade 60 Grade 125 Grade 150 Grade 200 Grade 300 Grade 425 Grade 500 Grade 650 Grade 800 Grade 1000 Grade 1300 Grade 1525
1 ⁄ 4 1 ⁄ 4 3 ⁄ 8 1 ⁄ 2 3 ⁄ 4 1 1 1 1 ⁄ 4 1 1 ⁄ 2 2 2 1 2 ⁄ 2 3 3 3
10 20 30 60 125 150 200 300 425 500 650 800 1000 1300 1525
17 33 50 100 208 250 333 500 708 833 1083 1333 1667 2167 2542
Element Model (Grade)
Number of Elements
Grade E 10 Grade E 20 Grade E 30 Grade E 60 Grade E 125 Grade E 150 Grade E 200 Grade E 300 Grade E 425 Grade E 500 Grade E 650 Grade E 800 Grade E 1000 Grade E 1300 Grade E 1525
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Dimensions B C In. In.
A In.
3 3 3 1 3 ⁄ 2 5 5 5 5 1 5 ⁄ 2 1 5 ⁄ 2 1 5 ⁄ 2
1 1 ⁄ 2 1 1 ⁄ 2 1 1 ⁄ 2 1 1 ⁄ 4 1 1 ⁄ 2 1 1 ⁄ 2 1 1 ⁄ 2 1 1 ⁄ 2 2 2 2 3 2 ⁄ 4 3 2 ⁄ 4 3 2 ⁄ 4 1 2 ⁄ 2
8 8 8
9
D In.
Weight
3 3 3 4 4 4 6 6 6 6 6
8 8 8
13 15 15 21 21 22 22 30 32 32 37 42
8 8 8
12
lb.
kg.
1.43 1.43 1.43 2.87 5.95 5.95 7.72 7.72 9.70 9.70 11.00 25.40 25.40 34.20 41.90
0.65 0.65 0.65 1.30 2.70 2.70 3.50 3.50 4.40 4.40 5.00 11.50 11.50 15.50 19.00
A mm
72 72 72 88
125 125 125 125 135 135 135 200 200 200 230
Metric Dimensions B C mm mm
D mm
35 35 35 32 39 39 39 39 50 50 50 68 68 68 65
75 75 75 100 100 100 150 150 150 150 150 200 200 200 300
210 210 210 315 365 365 515 515 545 545 745 805 805 925 1050
B
Model Grades 1503, 1504 & 2004
A
A
C
C Model Grades 2006–16512
B D M od el Gr ad es 10 , 2 0 & 30
Steel Housings — Flanged
Element Model (Grade)
Filter Model Pipe Size Flow Rate (Grade) Flg. scfm Nm3/hr
Grade 1503 3 Grade 1504 4 Grade 2004 4 Grade 2006 6 Grade 3004 4 Grade 3006 6 Grade 4506 6 Grade 6008 8 Grade 10510 10 Grade 16512 12
1500 1500 2000 2000 3000 3000 4500 6000 10500 16500
2550 2550 3400 3400 5100 5100 7650 10200 17850 28050
Specs DCNE CSNE CPNE CXNE ACNE
3 2 1 1 1
to ISO 8573-1:2001
4 2 1 1 1
Number of Elements
Grade 1500 Grade 1500 Grade 2000 Grade 2000 Grade 3000 Grade 3000 Grade 1500 Grade 1500 Grade 1500 Grade 1500
Max. Max. Particle Size Oil Content Class
Filter Element to ISO 8573-1:2001
D
M od el Gra de s 60 –1 52 5
1 1 1 1 1 1 3 4 7 11
58 58 58 1 59 ⁄ 4 72 1 75 ⁄ 4 1 83 ⁄ 2 86 3 ⁄ 4 100 3 113 ⁄ 4
Max. Oil Carryover at 68˚F a t 20˚C ppm mg/m3
Particle Removal in Microns
5 1 0.01 0.01 0.01
A In.
5.0 0.1 0.01 0.001 0.003
5.0 0.1 0.01 0.001 0.003
Dimensions B C In. In.
15 1 8 17 ⁄ 3 8 21 ⁄ 1 25 ⁄ 2 3 8 21 ⁄ 25.5 1 25 ⁄ 4 25 31 1 44 ⁄ 2
48 48 1 48 ⁄ 4 48 1 62 ⁄ 4 64 1 68 ⁄ 2 68 80 87
D In.
lb.
Weight kg.
A mm
10 1 6 ⁄ 2 13 1 7 ⁄ 2 13 1 7 ⁄ 2 1 23 ⁄ 2 23 30 16
165 175 320 360 38 5 420 58 0 650 800 1000
74 80 145 163 175 191 263 295 363 454
1472 1473 1473 1505 1829 1911 2121 2203 2540 2889
Metric Dimensions B C mm mm
381 435 543 648 543 648 641 635 787 1130
Pressure Loss Max. Temperature ˚F ˚C
248 248 248 248 77
Clean & Dry psi mbar
120 120 120 120 25
1 1 2 2 1
40 75 100 140 75
psi
Wet mbar
1 2 4 5 —
75 150 300 350 —
Change Element psi mbar
6 6 6 6
400 400 400 400
Min.every 6 mo nths
D mm
1219 1219 1226 1219 1581 1626 1740 1727 2032 2210 Max. Working Pressure psig barg
232 232 232 232 232
16 16 16 16 16
254 165 330 191 330 191 597 5 84 762 406 Element End Cap Color Code
Green Red Blue Black Black
Correction Factor
Operating psig Pressure barg Correction Factor
4 0.3 0.21
9 0.6 0.29
15 1 0.38
29 2 0.53
44 3 0.65
58 4 0.76
72 5 0.84
87
6 0.92
100 7 1
115 8
1.07
130 9 1.13
145 10 1.19
160 11 1.25
174 12 1.31
18 9 13 1.36
203 14 1.41
218 15 1.46
232 16 1.51
For maximum flow rate, multiply model flow rate show n i n the above table by the correction factor correspondi ng to the worki ng press ure. 5
C O M P R E S S E D A I R F I LT E R S HIGH TEMPERATURE — 1 MICRON DUST FILTERS, 450˚F, 150 PSIG •
Nomex outer layer is provided for high-temperat ure operatio n
•
Push-to-fit design used on threaded filters for easy filter eleme nt replacement
•
Multiwrap eleme nt co nstr uction provides optimum performa nce
ALUMINUM HOUSINGS,
STEEL HOUSINGS,
THREADED NPT CONNECTIONS
FLANGED CONNECTIONS
15 TO 650 CFM,
1500 TO 16,000 CFM,
SERIES HTDT
SERIES HTDF
•
•
Features a high-temperat ure d ust filter with heavy-duty bowl
•
Same filtration grade as al uminum filters
•
Identified with a n “F” suffix
Ribbed bowl facilitates removal whe n changing elements
•
U stamped for the USA a nd CRN approved for Canada
NOTE: Alloy filters shipped loose will have a special high-temperat ure black powder coat pai nt.
•
Differential pressure indicators are standard
•
Housings are freestanding and top-loading for easy element replacement
•
All grades of filter eleme nt e nd caps are molded, providing strength, durability and lo ng life
QuincyCompressor.com 6
|
Mad e in the U.S.A. |
The Science of Compressed Air
The Science of Compresse d Air
HIGH TEMPERATURE — SPECIFICATIONS & ENGINEERING DATA
Dust Filters — Threaded Filter Model
Element Model (Grade)
Number of Elements
HTDE 15 HTDE 30 HTDE 65 HTDE 75 HTDE 150 HTDE 300 HTDE 450 HTDE 650
1 1 1 1 1 1 1 1
Pipe Size Flow Rate NPT scfm Nm 3/hr
HTDT 15 HTDT 30 HTDT 65 HTDT 75 HTDT 150 HTDT 300 HTDT 450 HTDT 650
1 ⁄ 4 3 ⁄ 8 1 ⁄ 2 3 ⁄ 4 1 1 1 ⁄ 2 2 2
15 30 65 75 150 300 450 650
25 50 108 125 250 500 750 1084
A In.
Dimensions B C In. In.
D In.
lb.
kg.
1 2 ⁄ 2 1 2 ⁄ 2 1 4 ⁄ 2 1 4 ⁄ 2 1 4 ⁄ 2 3 5 ⁄ 4 3 5 ⁄ 4 3 5 ⁄ 4
1 ⁄ 2 1 ⁄ 2 1 1 ⁄ 2 1 1 ⁄ 2 1 1 ⁄ 2 2 2 2
2 2 6 6 6 7 7 7
0.5 0.6 5.7 5.7 7.3 16.5 16.5 22.0
0.25 0.27 2.60 2.60 3.30 7.50 7.50 10.00
6 1 7 ⁄ 2 12 12 1 15 ⁄ 2 21 21 25
Weight
A mm
Metric Dimensions B C mm mm
D mm
63 63 114 114 114 146 146 146
15 15 38 38 38 50 50 50
50 50 150 150 150 170 170 170
150 190 305 305 395 435 435 635
B
Models HTDF 1503, 1504 and 2004
A
A
C
C Models HTDF 2006–16512
B
Dust Filters — Flanged Filter Model
Pipe Size Flow Rate Flg. scfm Nm3/hr
HTDF 1503 HTDF 1504 HTDF 2004 HTDF 2006 HTDF 3004 HTDF 3006 HTDF 4506 HTDF 6008 HTDF 10510 HTDF 16512
Specs Filter Element
D
Models HTDT 65–650
Models HTDT 15 & 30
3 4 4 6 4 6 6 8
10 12
1500 1500 2000 2000 3000 3000 4500 6000 10500 16500
Particle Removal i n M icrons
2550 2550 3400 3400 5100 5100 7650 10200 17850 28050
Max. Oil Carryover at 68˚F at 20˚C p pm mg /m3
Element Model (Grade)
Number of Elements
HTDE 1500 HTDE 1500 HTDE 2000 HTDE 2000 HTDE 3000 HTDE 3000 HTDE 1500 HTDE 1500 HTDE 1500 HTDE 1500
1 1 1 1 1 1 3 4 7 11
A In.
58 58 58 1 59 ⁄ 4 72 1 75 ⁄ 4 1 83 ⁄ 2 86 3 ⁄ 4 100 113 3 ⁄ 4
D
Dimensions B C In. In.
15 171 ⁄ 8 213 ⁄ 8 25.5 21 3 ⁄ 8 1 25 ⁄ 2 1 25 ⁄ 4 25 31 1 44 ⁄ 2
48 48 1 48 ⁄ 4 48 1 62 ⁄ 4 64 1 68 ⁄ 2 68 80 87
D In.
lb.
kg.
A mm
10 1 6 ⁄ 2 13 1 7 ⁄ 2 13 1 7 ⁄ 2 1 23 ⁄ 2 23 30 16
165 175 320 360 38 5 420 58 0 650 800 1000
74 80 145 163 175 191 263 295 363 454
1473 1473 1473 1505 1829 1911 2121 2203 2540 2889
Pressure Loss Max. Temperature ˚F ˚C
High-temperature dust filter element grade HTDE 1 2 2 450 250
Clean & Dry psi mbar
psi
1.1
NA
75
Wet mbar
NA
Weight
Change Element psi mbar
Max. Working Pressure psig barg
Element End Cap Color Code
6
150
Brick Red
400
10
Metric Dimensions B C mm mm
381 435 543 648 543 648 641 635 787 1130
1219 1219 1226 1219 1581 1626 1740 1727 2032 2210
D mm
254 165 330 191 330 191 597 5 84 762 406
Correction Factor
Operating psig Pressure barg Correction Factor
145 10 0.34
290 20 0.57
435 30 0.71
5 80 40 0.86
725 50 1.0
For maximum flow rate, multiply model flow rate show n i n the above table by the correction factor correspondi ng to the worki ng press ure.
7
C O M P R E S S E D A I R F I LT E R S BREATHABLE AIR SYSTEMS 15 TO 30 CFM
Quincy Breathable Air Packages are complete systems designed to provide, clean, odor-free, taste-free, particle and liquid oil-free compressed air for sand blasting and/or painting hoods. The 15-cfm system has two outlet ports and can accommodate two suits. The 30-cfm package has four outlet ports and can accommodate four suits. The system provides absolute filtration down to 0.01 micron and oil removal down to 0.003 ppm. Special non-shedding, high-speed carbon granules increase vapor-holding capacity.
•
Push-to-fit design
•
PNF drain layer
•
Aluminum ho usings with electrophoretic coating to prevent corrosion
Pressure differential indicator
•
Multiwrap constr uction
•
WSNT moisture separator
•
•
CSNT 1 micron, 0.1 ppm Coalescer
Air pressure regulator and ga uge
•
QUDT with CPNT 0.01 micro n, 0.01 ppm and .003 ppm activated carbo n absorber
•
Activated carbon eleme nt impregnated with red dye oil i ndicator
•
Wallmounting or floor-mounting configuratio n
•
Color-coded end caps
•
Compressed air heater optio n
The System Includes: •
OVER & UNDER DUPLEX 10 TO 50 CFM, SERIES OUDT
Using a unique two-sided head, Quincy’s Over & Under Duplex filter combines a CPN Series (0.01-micron, 0.01-ppm) coalescer with an ACN Series (.003-ppm) activated carbon absorber. This compact, twostage, single-piece filtration system saves space, is easy to install and delivers ISO 8573.1 class 1 compressed air. The Over & Under is ideal for food and beverage, instrumentation and pharmaceutical applications. The System includes: •
Combination Coalescer and Activated Carbon Absorber
•
Two f unctions i n one unit
•
Space-savi ng Over & Under config uratio n
•
Push-to-fit design for easy filter element replacement
•
Multiwrap eleme nt co nstr uction ensures optimum performance
•
Non-sheddi ng, high-speed carbo n granules increase vapor-holding capacity
•
Aluminum ho usings with electrophoretic coating to prevent corrosion.
•
Standard press ure differential indicator
•
Standard a utomatic condensate drain
QuincyCompressor.com 8
|
Mad e in the U.S.A. |
The Science of Compressed Air
The Science of Compresse d Air
BREATHABLE AIR, OVER & UNDER DUPLEX — SPECIFICATIONS & ENGINEERING DATA
Breathable Air Packages Pipe Size NPT
Element Model (Grade)
Number of Elements
A In.
Wallmounted Breathable Air Packages 1 BWST 15 ⁄ 2 15 25 4 1 BWHT 15 ⁄ 2 15 25 4 3 BWST 30 ⁄ 8 2 15 25 3 BWHT 30 ⁄ 8 2 15 25
BAEK 15 BAEK 15 BAEK 30 BAEK 30
1 Kit 1 Kit 1 Kit 1 Kit
1 10 ⁄ 4 153 ⁄ 4 1 10 ⁄ 4 3 15 ⁄ 4
123 ⁄ 4 18 123 ⁄ 4 18
Frame-Mounted Breathable Air Packages 1 BFST 15 ⁄ 4 30 50 4 1 BFHT 15 ⁄ 4 30 50 4 3 BFST 30 ⁄ 8 4 30 50 3 BFHT 30 ⁄ 8 4 30 50
BAEK 15 BAEK 15 BAEK 30 BAEK 30
1 Kit 1 Kit 1 Kit 1 Kit
193 ⁄ 4 193 ⁄ 4 193 ⁄ 4 193 ⁄ 4
NA NA NA NA
Filter Model
Air Outlet Ports
Flow Rate scfm Nm 3/hr
Models BWST 15 & 30
OUDT OUDT OUDT OUDT
Pipe Size Flow Rate NPT scfm Nm 3/hr
10 15 30 50
1 ⁄ 4 1 ⁄ 4 3 ⁄ 8 1 ⁄ 2
10 15 30 50
17 25 50 83
Specs
Max. Max. Particle Size Oil Content Class
Filter Element to ISO 8573-1:2001
lb.
kg.
A mm
123 ⁄ 4 1 13 ⁄ 4 123 ⁄ 4 1 13 ⁄ 4
3 4 3 4
0.50 0.60 5.70 5.70
0.25 0.27 2.60 2.60
280 418 280 418
360 498 360 498
323 337 323 337
77 100 77 100
173 ⁄ 4 173 ⁄ 4 173 ⁄ 4 173 ⁄ 4
193 ⁄ 4 193 ⁄ 4 193 ⁄ 4 193 ⁄ 4
2.35 2.35 2.35 2.35
1.05 1.05 1.05 1.05
500 500 500 500
NA NA NA NA
450 450 450 450
500 500 500 500
Weight
to ISO 8573-1:2001
Element Model (Grade)
Number of Elements
A In.
OUDK 10 OUDK 15 OUDK 30 OUDK 50
1 Kit 1 Kit 1 Kit 1 Kit
3 3 3 1 3 ⁄ 2
Max. Oil Carryover at 68˚F a t 20˚C ppm mg/m3
Particle Removal in Microns
Dimensions B C In. In.
6 6 6
7 7 7 9
8
D In.
lb.
kg.
A mm
Metric Dimensions B C mm mm
3 3 3 4
1.90 1.90 1.90 2.75
0.85 0.85 0.85 1.25
72 72 72 90
150 150 150 200
Weight
Pressure Loss Max. Temperature ˚F ˚C
D mm
Models OUDT 10–50
Models BFST 15 & 30
Over & Under Duplex Filter Model
D In.
Metric Dimensions B C mm mm
Dimensions B C In. In.
Clean & Dry psi mbar
psi
Wet mbar
Change Element psi mbar
173 173 173 225 Max. Working Pressure psig barg
Breathable Air Package Kit BAEK 1 1
>0.01
>0.003
>0.003
77
25
3.7
250
6.6
950
Min.every 6 mo nths 145
Duplex Filter Kit (OUDK) CPNE 1 1 ACDE 1 1
0.01 0.01
0.01 0.003
0.01 0.003
248 77
120 25
2.2 1.1
150 75
4.4 NA
300 NA
Min.every 6 mo nths 232
6
400
232
10 16 16
D mm
75 75 75 100 Element End Cap Color Code Red/Blue/Black
Blue Black
Correction Factor
Operating psig Pressure barg Correction Factor
4 0.3 0.21
9 0.6 0.29
15 1 0.38
29 2 0.53
44 3 0.65
58 4 0.76
72 5 0.84
87
6 0.92
100 7 1.0
115 8
1.07
130 9 1.13
145 10 1.19
160 11 1.25
174 12 1.31
18 9 13 1.36
203 14 1.41
218 15 1.46
232 16 1.51
For maximum flow rate, multiply model flow rate show n i n the above table by the correction factor correspondi ng to the worki ng press ure.
WARNING: The Breathable air systems described i n this brochure
will not remove certai n types of gases, including Carbon Monoxide (CO) and Carbon Dioxide (CO2 ). These Breathable Air Systems are desig ned to offer the user protection in potentially harmf ul environments. It is therefore imperative the prod ucts be
correctly installed and properly controlled by a competent person. Properly controlled means the equipment installed should be f ully checked prior to every use. Should any fault be discovered, it must be repaired or the failed component replaced to guarantee f ull working order before use.
9
C O M P R E S S E D A I R F I LT E R S M E C H A N I C A L M O I S T U R E S E PA R AT O R S 20 TO 1500 CFM, 230 PSIG, SERIES WSNT
Quincy Mechanical Moisture Separators are designed to remove bulk liquids and large volumes of water. They are typically installed downstream of aftercoolers, air receivers, refrigerated air dryers and at strategic points of use throughout the compressed air distribution system. The design employs an internal spinner to create a centrifugal action that effectively removes large quantities of water. •
Large s ump a nd quiet zone to prevent moisture re-entrai nment
•
Modular design allows for easy i nstallation of m ultiple housings a nd saves energy
•
Annular seal and captive O–ri ng prevent leaks
•
1 4" to 3 NPT) feat ure Aluminum ho usings ( ⁄ electrophoretic coating to preve nt corrosion
•
1 4" to 3" NPT) carry Aluminum ho usings ( ⁄ a 10-year ho using g uarantee
•
Standard a utomatic condensate drain
SPECIFICATIONS & ENGINEERING DATA Metric
Moisture Separators Filter Model
Pipe Size Flow Rate NPT scfm Nm3/hr
WSNT 20 WSNT 30 WSNT 63 WSNT 127 WSNT 176 WSNT 318 WSNT 427 WSNT 675 WSNT 1000 WSNT 1500
Specs Filter Model
WSNT
1 ⁄ 4 3 ⁄ 8 1 ⁄ 2 3 ⁄ 4 1 11 ⁄ 4 1 1 ⁄ 2 2 1 2 ⁄ 2 3
20 30 63 127 176 318 427 675 1000 1500
Max. Recommended Operating Temp. ˚F ˚C
248
120
Dimensions B C In. In.
A In.
35 50 112 216 300 540 725 1150 1700 2550
3 3 1 3 ⁄ 2 5 5 5 1 5 ⁄ 2 1 5 ⁄ 2
1 1 ⁄ 4 1 1 ⁄ 4 1 1 ⁄ 4 1 1 ⁄ 2 1 1 ⁄ 2 1 1 ⁄ 2 2 2 23 ⁄ 4 23 ⁄ 4
8 8
1 8 ⁄ 4 1 8 ⁄ 4 1 8 ⁄ 4
1.5
0.7
3 3 4 4 4 4 6 6
12 12 12 19 19 24 24
Min. Typical Recommended Pressure Loss Operating Temp. At Rated Flow psi mbar ˚F ˚C
35
D In.
50
Weight lb. kg.
1.45 1.45 2.90 5.95 5.95 5.95 9.70 9.70 25.5 25.5
8 8
0.65 0.65 1.30 2.70 2.70 2.70 4.40 4.40 11.5 11.5
A mm
72 72 88
125 125 125 135 135 200 200
Dimensions B C mm mm
D mm
35 35 32 39 39 39 50 50 68 68
75 75 100 100 100 100 150 150 200 200
210 210 210 300 300 300 480 480 590 590
Max. Working Pressure psig barg
232
16
Correction Factor
Operating psig Pressure barg Correction Factor
4 0.3 0.21
9 0.6 0.29
15 1 0.38
29 2 0.53
44 3 0.65
58 4 0.76
72 5 0.84
6 0.92
100 7 1
Operating psig Pressure barg Correction Factor
115
130 9 1.13
145 10 1.19
160 11 1.25
174 12 1.31
189 13 1.36
203 14 1.41
218 15 1.46
232 16 1.51
8
1.07
87
For maximum flow rate, multiply model flow rate show n i n the above table by the correction factor correspondi ng to the worki ng press ure.
QuincyCompressor.com 10
|
Mad e in the U.S.A. |
The Science of Compressed Air
The Science of Compresse d Air
QUINCY SYSTEM PRESSURE TRANSMITTERS
Quincy System Pressure Transmitters sense pressure, differential pressure or both at specific points throughout a compressed air system. Accurate to half of 1%, a 4 to 20 mA signal continuously transmits readings to the system’s main control station. Continuous and accurate pressure tracking facilitates periodic compressed air audits and enables the automation and/or operator to monitor the system and adjust controls for optimum efficiency. •
Reduce e nergy and filtration costs
•
Improve air treatme nt efficiency
•
Monitor critical applications
•
24/7 operation
•
Simple and cost-effective installation
•
Guaranteed for 5 years
•
Rugged NEMA 4/IP65 rati ng
ACCESSORIES
Quincy filtration products come standard with mechanical condensate drains and are available with… •
Optional electronic timer drai ns
•
Optional p neumatic no-loss drains
•
Optional electronic no-loss drains
Quincy Filters are equipped standard with top-mounted pressure indicators. •
Pop-up for 10 cfm thro ugh 30 cfm 1 ( ⁄ 2" NPT & 3/8" NPT)
•
Gauge for 50 cfm thro ugh 16,500 cfm 1 ( ⁄ 2" NPT thro ugh 12" FLG)
Multiple filters can be ganged together using the available two- and three-unit connecting kits. •
Eliminates leaks, saving e nergy
•
Easy and space-saving i nstallation
Aluminum Alloy filters can be wallmounted using the available wallmounting brackets. •
Provides easy and flexible i nstallation 11
COMPRESSED AIR SYSTEMS BEST PRACTICE The Science of Compresse d Air
Air Quality Classification ISO 8573.1
QGV-100 quincycompressor.com
Moisture Solids ISO PDP ISO
Micron
QPNC-500 quincycompressor.com
Quincy Rotary Screw
WSN Wet Bulk Receiver Liquid 1gal/CFM DP1 DP2
CSN 1 Micron 0.1 PPM DP3
Refrigerated Air Dryer CPN Dry QPNC Non-Cycling 0.01 Micron Receiver QPCD Cycling 0.01 PPM 5gal/CFM DP4 DP5
Wet System Avg. ∆P
Oil PPM ISO
psi
Mbar
0.01
1
+38˚F
4
0.01
1
10.7
738
0.01
1
+38˚F
4
0.003
1
11.8
814
ACN 0.003 PPM Vapor & Odors 0.01
QDHT-1000 quincycompressor.com
1 -100˚F 1 0.001 1 14.2 979 NOTE: Requires CXN (.001 PPM) filter in series with standard CPN prefilter.
1
2
-40˚F
2
0.01
1
9.2
634
0.01
1
-40˚F
2
0.003
1
10.3
710
1
2
-40˚F
2
0.01
1
9.2
634
0.01
1
-40˚F
2
0.003
1
10.3
710
1
2
+50˚F
6
0.01
2
7.8
538
0.01
1
+50˚F
6
0.003
1
10.0
689
quincycompress or.com
Quincy Reciprocating
AC
WSN DCN CSN CPN CXN ACN OUD HTD
Moisture Separator Particulate/Coarse Coalescer STD 0.1 PPM Coalescer, 1 Micron Polishing 0.01 PPM Coalescer Xtra 0.001 PPM Coalescer Activated Carbon Absorber Over + Under Duplex High Temperature, 1 Micron
QPNC QPCD QDTS QDTH QDHP QDBP QPHT
Non-Cycling Refrigerated Dryer Cycling Refrigerated Dryer Small Heatless Dryer Industrial Heatless Dryer Heated Purge Dryer Blower Purge Dryer High Temp. Refrigerated Dryer
WOS Water/Oil Separator AC After Cooler DP Drain Point
WSN Bulk Liquid DP6
CPN Desiccant Heatless Air Dryer CSN Dry 0.01 Micron QDTS—Small 1 Micron Receiver 0.01 PPM QDTH—Industrial Particulate 5gal/CFM DP7 -40˚F PDP
ACN 0.003 PPM Vapor & Odors
QDHP-1000 quincycompressor.com
CPN Desiccant Heated Air Dryer CSN (NPT) Dry 0.01 Micron QDHP—Heated Purge HTD (FLG) Receiver 0.01 PPM QDBP—Blower Purge 1 Micron 5gal/CFM DP8 -40˚F PDP Particulate
ACN 0.003 Micron
QPHT-40
quincycompressor.com
WOS Water/Oil Separator OUD DCN 5 Micron 5 PPM DP9
©2005 Quincy Compressor an E nPro Ind ustries company All rights reserved. Litho i n U.S.A. (QATF-001 03/05)
High Temperature/ Refrigerated Air Dryer QPHT—High Temp. DP10
ACN 0.003 PPM Vapor & Odors
CSN 1 Micron 0.1 PPM DP11
Approximate Liquid Removal 100 CFM, 100 psi, 80˚F, 4000 hrs./yr., 2 PPM Drain Gallons Drain Gallons Drain Gallons CPN Point per Year Point per Year Point per Year 0.01 Micron 1 3000 5 140 9 300 0.01 PPM 2 3 4
2000 305 1300
6 7 8
3000 310 310
10 11
4320 120
701 North Dobso n Ave nu e | Bay Minette, AL 36507 | Pho ne 251.937.5900 | Fax 251.937.71 82 | Nearest Distrib utor: 888 .424.7729 | Email: info@ qu incycompressor.com