Norm-Centrifugal Pumps PN 10 Series NT
Pump dimensions acc. to DIN EN 733 with additional sizes Technical requirements acc. to DIN ISO 9905
Application For pumping pure water, industrial water, sea water, condensate, oils, brines, lyes, hot water. The liquids to be pumped must not contain any abrasive particles nor chemically attack the pump materials. Main fields of application In cooling and heating circuits in circulating, water supply, water treatment, irrigation, desalinization, dedusting and spray painting installations as well as in air-conditioning, refrigerating, swimming pool and industrial engineering. Design and series construction Horizontal volute casing centrifugal pump with axial inlet, single-flow, single or two-stage, in process design. Series construction according to the modular system. Shaft bearing in a bearing housing which can be optionally provided with a support foot. With bearing housing size 585 and 700 the foot belongs to serial equipment, with bearing housing size 228 it is generally not available. Stable mounting with feet cast on volute casing. The additional two-stage pump sizes correspond in their outer dimensions to the respective single-stage sizes. Due to the two-stage design good efficiencies and low NPSH values are achieved at high delivery heads. Capacity With the sizes according to DIN EN 733, the pump capacity exceeds the required rated power considerably. By additional sizes, the performance range acc. to DIN EN is increased. Performance data Flow Delivery head Temperature of the liquid pumped Inlet pressure Outlet pressure
Q H t ps pd
up to up to up to
16 bar
Inlet pressure plus maximum delivery head must not exceed the outlet pressure.
Branch positions and flanges Suction branch: axial Delivery branch: radially upwards Flanges: Flange s: up to DN 150 acc. to EN 1092-2 PN 16 DN 200 and above acc. to EN 1092-2 PN 10 Shaft coupling and safety guarding Safety guarding according to DIN EN 294 is supplied as soon as the scope of supply includes pump, base plate and shaft coupling (acc. to DIN 740 with or without spacer element). The safety standards acc. to DIN EN 809 are met.
VM 538 GB/05.06 – Ident-No. 795 213
Bearing and lubrication By two groove ball bearings acc. to DIN 625, grease-lubricated for the whole service life, bearing clearance C3. Dismantling of the insert unit
When using the spacer coupling the insert unit can because of the process design be dismantled towards the motor side, whereas the volute casing and the motor may remain on the base plate and the pipes on the volute casing. Combination of structural components The table on page 3 shows the combination possibilities of structural components of all NT sizes. The modular system allows reduced stockkeeping of spare parts. Explosion protection The pump fulfils the requirements according to EC Explosion Protection Directive 94/9/EG (ATEX 100a) for equipment of equipment group II, category 2 G. Categorisation into temperature classes according to EN 13 463-1 depends on the temperature of the pumped liquid. The max. permissible temperature of the pumped liquid for the respective temperature classes are shown in the specific order data sheet. Note: In Note: In case of the operation of a category 2 pump, the unacceptable heating of the pump surfaces caused by a possible operational fault must be prevented by a control mechanism.
3
2300 m /h 145 m 140 °C
up to
Shaft sealing By maintenance-free standard mechanical seal in unbalanced design in different materials (see page 2) or by gland packing.
Drive Standard: surface-cooled, three-phase squirrel-cage motors, IM B3 type of construction, degree of protection IP 55 according to IEC standard, class F insulation. Performances and main dimensions according to DIN 42 673. Further drive options are possible. Connections The following connections are provided: FD FF LO PM2
Draining Filling Leakage outlet Pressure gauge
Connection FF not provided provided in sizes 20-160/01, 25-200/01 25-200/01 und 2/25200/01. Refilling possible at connection PM2.
Base plates Standard: channel steel base plate. Optionally: massive base plate of cast iron (dimensions acc. to DIN 24 259) with a drip channel for leakage. Installation dimensions are available in ALLWEILER drawing archive ALL2CAD. 1
Series NT
With the two-stage additional pump sizes, the number of stages is placed with a slash in front of the delivery branch nominal width, e.g. NT 2/32-200/01...
This abbreviation is entered on the nameplate. With the two-stage additional pump sizes, the actual impeller diameter relates to the second stage.
Shaft sealings with temperature and pressure limits Valid for all materials of the pumps Mechanical seal, uncooled
Unbalanced
Flushing Abbreviation
Internal self flushing
U3D
U3.20D
U3.22D
hard carbon, antimony impregnated
oxide ceramics
silicone carbide
silicone carbide
CrNiMo steel EPDM FPM
CrNiMo steel EPDM FPM
CrNiMo steel EPDM FPM
Bellow
-
-
EPDM
FPM
-
-
BVEGG
BVVGG
Q1Q1EGG
Q1Q1VGG
AQ1EGG
AQ1VGG
Admissible temperature (°C) of pumped liquid and pump outlet pressure pd (bar)
Centrifugal pumps at all bearing housing sizes
U3.12D
silicone carbide
Stationary ring
Material code DIN EN 12 756
U3.9D
hard carbon, resin impregnated
Rotating ring
Metal parts O-rings
U3.1D
°C / bar
°C / bar
°C / bar
single-stage
100 / 10
100 / 10
100 / 10
100 / 10
140 / 10
140 / 10
two-stage
100 / 16
100 / 16
100 / 16
100 / 16
140 / 16
140 / 16
with water max. 90 °C
Other mechanical seal designs upon request.
Gland packing
Uncooled
Sealing Abbreviation
internal
external
U1B
U1C
Packing rings
graphite-PTFE basis
Centrifugal pumps at all bearing housing sizes
Admissible temperature (°C) of pumped liquid and pump outlet pressure pd (bar) °C / bar
single-stage
125/10
Materials Denomination
Part-No. st
Material code
nd
1 2 stage stage
W1
W2
W3
W 10
W 18
W 19
W 88
W 97
Volute casing
102... 102... EN-GJL-250 EN-GJL-250
CC333G
Impeller(s)
230... 230... EN-GJL-200
CC333G
CC333G
EN-GJL-200
CC333G
EN-GJL-200
CC333G
EN-GJL-200
CC333G
CC333G
CC333G
EN-GJL-200
CC333G
EN-GJL-200
CC333G
EN-GJL-200
CC333G
EN-GJL-250
Diffuser
-
171... EN-GJL-200
Stage casing
-
108… EN-GJL-250 EN-GJL-250
CC333G
Casing cover
161... 161... EN-GJL-250 EN-GJL-250
CC333G
Shaft
210... 210...
1.4021
1.4021
1.4571
Bearing housing 330... 330... EN-GJL-250 EN-GJL-250 EN-GJL-250
2
EN-GJS-400-15 EN-GJL-250 EN-GJL-250 EN-GJS-400-15 EN-GJS-400-15
W 98 CC333G
EN-GJL-250 EN-GJL-250 EN-GJS-400-15 EN-GJS-400-15
CC333G
EN-GJS-400-15 EN-GJL-250 EN-GJL-250 EN-GJS-400-15 EN-GJS-400-15
CC333G
1.4021 EN-GJL-250
1.4571
1.4571
1.4571
EN-GJL-250 EN-GJL-250 EN-GJL-250
1.4571
1.4021
EN-GJL-250
EN-GJL-250
With bearing housing size 585 the pump side (liquid contact) in the material stated above and motor side in 1.7139 VM 538 GB/05.06 – Ident-No. 795 213
Series NT Combination of structural components The table below shows the combination possibilities of structural components and parts of the standard sizes including additional sizes. Within a vertical column, parts with identical numbers are interchangeable. The modular system allows a reduced stockkeeping of spare parts. Bearing housing size
Pump size acc. to DIN EN 733
Volute Impeller casing
Impeller
Additional size st
NT 228
360
20-160/01
1
-
25-160/01
2
-
25-200/01
-
2/25-200/01
32-160/01
-
32-200/01
-
5
-
-
2
-
-
-
-
2
2
-
1
1
1
1
3
3
3 4 5
40-200/01
-
7
6
40-250/01
-
-
2/40-250/01
8
-
-
9
8
50-200/01
-
10
9
50-250/01
2/50-250/01
11
-
-
-
1
1
1
1
-
-
12
11
65-200/02
-
13
12
80-160/01
-
14
13
15
14
-
-
1
1
1
2
2
3
3
-
-
-
-
-
2
2
1 2
2
2
2
4
2
3
-
-
-
-
2
2
4
3
1 3
-
2
-
2
-
2
-
1
3
2
2
-
5 6
3
7
20
19
80-315/01
-
21
20
100-200/01
-
22
21
100-250/01
-
23
22
100-315/01
-
24
23
125-200/01
-
25
24
125-250/01
-
26
25
-
27
26
28
27
-
80-400/02
100-400/02
-
29
28
125-315/01
-
30
29
125-400/02
-
31
30
32
31
-
150-250/02
150-315/01
-
33
32
150-400/02
-
34
33
-
200-250/02
35
34
-
200-315/01
36
35
-
200-400/01
37
36
-
250-315/01
38
37
-
250-400/01
39
38
-
300-315/03
40
39
-
300-400/03
41
40
-
300-315/03
40
41
-
300-400/03
41
42
VM 538 GB/05.06 – Ident-No. 795 213
-
-
-
2
30
8
-
-
4
2
-
30
3
16
80-250/01
-
1
15 17
30
3
17
18
30
1
16 18
-
1
-
19
30
1
-
-
-
2
65-315/01
65-400/01
16 30
1
65-250/01
80-200/02
16
2
10
65-160/01
100-160/01
-
7
50-160/01
150-200/01
700
4
-
6
-
585
3
Ø
-
-
-
530
2/32-200/01
nd
1
40-160/01
-
470
NT
Shaft sealing Mecha- Gland nical packing seal
1 2 stage stage
-
-
Diffuser Stage Intermediate Casing Bearing Shaft Support casing ring cover housing foot
5
3
4
5 7 5
-
40
40
50
50
65
65
80
80
6
2 7 8 9
6 -
-
-
-
-
7
4
5
10 9
6
10
7
11 12
-
-
-
-
-
8 5
-
-
-
-
-
9
-
-
-
-
-
9
6
13 14
6
7
14
3
Series NT Negligible axial thrust by fine adaptation of the relief bores.
Pressure safe casing parts designed for high reliability of operation.
Flanges according to DIN EN 1092-2 PN 10/16, other flange designs possible.
Connection dimensions and capacities according to DIN EN 733.
Shaft sealing by mechanical seal or gland packing according to the operating conditions. Groove ball bearings rigid and lubricated for the whole service life.
No offset of the shaft because of one-piece bearing housing.
Optimized hydraulic parts according to DIN EN 733 with very good efficiencies and NPSH values.
Two-stage sizes with their outer dimensions correspond to the respective single-stage sizes.
Large delivery heads with two-stage sizes (2/25-200/01, 2/32-200/01, 2/40-250/01, 2/50-250/01). The connection dimensions correspond with the single stage design.
4
Adaptation to changing operating conditions possible by turning down the impeller.
Large selection of materials.
Process design; when dismounting the pump the volute casing remains in the piping.
By additional pump sizes performance range according to DIN EN 733 is increased.
Reduced stockkeeping of spare parts due to use of as much non-variable parts as possible (modular system).
VM 538 GB/05.06 – Ident-No. 795 213
Series NT Performance graphs n = 1450 1/min
n = 2900 1/min
Valid for ρ = 1 kg/dm³ and ν = 1 mm²/s. Exact performance data to be taken from the individual characteristics and the selection programme ALLSELECT.
VM 538 GB/05.06 – Ident-No. 795 213
5
Series NT n = 1750 1/min
n = 3500 1/min
Valid for ρ = 1 kg/dm³ and ν = 1 mm²/s. Exact performance data to be taken from the individual characteristics and the selection programme ALLSELECT.
6
VM 538 GB/05.06 – Ident-No. 795 213
Series NT Sectional drawings Sizes on bearing housing size 228
U3 ... D mechanical seal unbalanced
Sizes on bearing housing size 360
Bearing housing size 360, two-stage, U3 ... D - mechanical seal unbalanced
VM 538 GB/05.06 – Ident-No. 795 213
Casing cover design with sizes 2/40-250 and 2/50-250
7
Series NT Sizes on bearing housing sizes 360, 470 and 530
U3 ... D mechanical seal unbalanced
Design on bearing housing size 530
8
Design with intermediate ring
VM 538 GB/05.06 – Ident-No. 795 213
Series NT Sizes on bearing housing size 585
U3 ... D mechanical seal unbalanced
Gland packing with internal sealing U1B
VM 538 GB/05.06 – Ident-No. 795 213
Gland packing with external sealing U1C
Mechanical seal unbalanced U3.9D, U3.12D
9
Series NT Sizes 300-315 and 300-400 on bearing housing 585
U3 … D - mechanical seal unbalanced
10
VM 538 GB/05.06 – Ident-No. 795 213
Series NT Sizes 300-315 and 300-400 on bearing housing 700
U3 … D - mechanical seal unbalanced
Design with wear ring V2
VM 538 GB/05.06 – Ident-No. 795 213
Connection C01 on the volute casing
Detail X on the casing cover
11
Series NT List of components Denomination Volute casing Stage casing Casing cover Casing cover Casing cover Casing cover Casing cover Suction cover Diffuser Pump frame Foot Support foot Support foot Shaft Shaft Impeller st Impeller 1 stage nd Impeller 2 stage Radial ball bearing Radial ball bearing Radial ball bearing Radial ball bearing Cylindrical roller bearing Bearing housing Bearing cover Bearing cover Gasket Gasket Seal ring Seal ring Seal ring Seal ring Seal ring Seal ring Seal ring O-ring O-ring O-ring O-ring V-ring V-ring Mechanical seal Shaft seal housing Stuffing box gland Lantern ring Gland packing Wear ring Wear ring Thrower Intermediate ring Threaded ring Nilos ring Nilos ring Shaft sleeve Spacer sleeve Clamping sleeve Spacer disc Spacer disc Spacer disc Compensating disc
12
Part-No. 102.01 108.01 161.01 161.03 161.05 161.10 161.12 162.01 171.01 181.01 182.01 183.01 183.10 210.01 210.02 230.01 230.02 230.03 321.01 321.02 321.03 321.04 322.01 330.01 360.01 360.02 400.01 400.02 411.01 411.02 411.03 411.04 411.05 411.06 411.37 412.01 412.06 412.07 412.10 424.01 424.02 433.01 441.01 452.01 458.01 461.01 502.01 502.02 507.01 509.01 514.01 516.01 516.02 523.01 525.01 531.01 551.01 551.10 551.12 557.01
Denomination Rivet Shim plate Venting Pipe fitting Hexagon head bolt Hexagon head bolt Hexagon head bolt Hexagon head bolt Hexagon head bolt Hexagon head bolt Hexagon head bolt Stud bolt Stud bolt Stud bolt Stud bolt Screw plug Screw plug Screw plug Screw plug Screw plug Screw plug Screw plug Setscrew Setscrew Jacking screw Jacking screw Jacking screw Socket head cap screw Socket head cap screw Socket head cap screw Socket head cap screw Socket head cap screw Socket head cap screw Socket head cap screw Hexagon nut Hexagon nut Hexagon nut Hexagon nut Impeller nut Circlip Circlip Circlip Spring disc Spring ring Key Key Key Cup spring Nameplate
Part-No. 565.01 592.10 672.01 730.01 901.03 901.04 901.05 901.10 901.11 901.12 901.13 902.01 902.03 902.05 902.06 903.01 903.02 903.03 903.04 903.05 903.06 903.26 904.01 904.05 908.01 908.02 908.03 914.01 914.02 914.03 914.04 914.05 914.07 914.10 920.01 920.03 920.05 920.06 922.01 932.01 932.04 932.10 934.01 936.01 940.01 940.02 940.03 951.01 971.01
Connections for: BI External sealing FD Draining FF Filling FV Venting LO Leakage outlet PM1 Pressure gauge PM2 Pressure gauge
VM 538 GB/05.06 – Ident-No. 795 213
Series NT Main dimensions Sizes on bearing housing sizes 228, 360, 470, 530 and 585
Dimensions in mm. Sense of rotation: clockwise, as seen from the driving side.
Bearing Exter- Drain- Fill- Vent- Leakage Preshousnal ing ing ing outlet sure ing sealgauge size ing Bl
FD
FF
FV
LO
PM2 connection FD in sizes
228
G⅛
G¼ G¼ G⅛
G¼
G¼
360
G¼
G¼ G¼ G¼
G⅜
G¼
25-200/01 and 2/25-200/01 = G ½
470
G¼
G⅜ G⅜ G⅜
G⅜
G⅜
connection FF in sizes
530
G⅜
G⅜ G⅜ G½
G⅜
G⅜
585
G⅜
G⅜ G⅜ G½
G⅜
G⅜
2-stage sizes
-
G¼ G¼ G¼
G⅜
G¼
20-160/01, 25-200/01 and 2/25-200/01 not provided. Refilling possible at connection PM2
in size 20-160/01 and
25-160/01 laterally
Flanges: up to DN 150 acc. to EN 1092-2 PN 16 DN 200 and above acc. to EN 1092-2 PN 10 DNd DNs
D
bf
k
g
No. of holes
25 32 40 50 65 80 100 125 150 200 250 300
115 140 150 165 185 200 220 250 285 340 395 445
16 18 18 20 20 22 24 26 26 26 28 28
85 100 110 125 145 160 180 210 240 295 350 400
14 19 19 19 19 19 19 19 23 23 23 23
4 4 4 4 4 8 8 8 8 8 12 12
VM 538 GB/05.06 – Ident-No. 795 213
13
Series NT Main dimensions Dimensions in mm without commitment. Tolerances of the connection dimensions according to DIN EN 735.
Bearing housing size
228
Pump size
20-160/01 25-160/01 25-200/01 2/25-200/01
Suction Disflange charge flange
DNS
DNd
25
25
40
25
32-160/01 32-200/01
50
32
Pump dimensions
a
f
65
80-160/01
100
80
100-160/01
125
100
80
65
160
180
100 70
240 190
200
125 95 15 4 28
50
n4
w
s
x
133 162 160 200 148 136
45
125
-
-
-
M10
60
17 28 19 5
M12
80
24 50 27 8
100
80
164 184 200 250
18 4 28
182 208 200 280 470
125
280 212
125 95
100
100
210 231 250 315 165 203 200 189 224 225 220 250
140
196 236 250
280
25 6 30 18 4 28
45 360 280 160 120
125 95
25 6 30 80
18 25
315
47 45 47
4 28
M16
400 315 420 335 345 280
M12
45 360 280
160 110 340
160 120 6 30
32 80 35 10 M16
47 400 315
120
125
150-200/01
200
150
160
214 268 280 370 100 27
200 150
550 450
M20
80-400/02
100
80
125
246 265
160 120
435 355
M16
100-400/02
125
100
150
125
212 255
140
200-250/02 200-315/01
264
200-400/01 250-315/01 250-400/01
300
160
283
500 400
315 400
200 250
262 330 355 425
200
270 335
180
315 374
225
140
42 110 45 12
180
60 105 64 18
239 271 280 400
180
250
160 110 370 M 20
280 375 100 27 6 31 200 150 47 550 450
277 305 315 450 200
250
80 25
226 252 530 231
150
18
355
256 272 280 355
150-250/02 200
100
400 315
150
150-400/02
u
165 200 200 280
125
100-200/01
160 110 260
320 250
202 219 225 280 80
80-315/01
150-315/01
t
265 212
170 180 225
163 188 180 250 65
125-400/02
l
320 250
100 70
65
80-200/02
125-315/01
d
320 250
239 255 250 355
125-250/01
585
123 130 133 145
100
100-315/01
530
- 220 180
n3
265 212
65-400/01
125-200/01
n2
- 100 70
156 169 180 225
80
100-250/01
-
m2 m3 n1
125 135 160 180
50
65-250/01
470
12
50
2/50-250/01
80-250/01
14
m1
124 130 160 180
100 360
65
50-250/01
65-315/01
160
50
c c1 e
150 156 180 225 65
50-200/01
65-200/02
145
b
123 123 132 160
80
40
40-250/01
65-160/01
h2
Shaft end acc. to DIN 748
123 123 132 160
40-200/01
50-160/01
h1
Extension for dimenscrews sion
132 132 160 180
40-160/01
2/40-250/01
b2
63 228 100 108 112
2/32-200/01
360
b1
Foot dimensions
585
325 408 350 440
355 400
450 110 27 500 100 560 130 30 600 120
200 150 10 42
260 190 280 200
550 450 65
690 560 630 500
M 20 250 200 410
M 24 M 27
Installation dimensions are available in ALLWEILER drawing archive ALL2CAD.
14
VM 538 GB/05.06 – Ident-No. 795 213
Series NT Main dimensions Size 300-315 and 300-400 on bearing housing 585 and 700
Bearing housing size
FD
FF
FV
LO
PM1
PM2
585
G½
G⅜
G½
G⅜
-
G⅜
700
G½
G⅜
G½
G½
G⅜
G⅜
Pump size Bearing housing size
Pump dimensions
a 300-315/01 300-400/01
585 700 585 700
325
f 730 795 700
h1
h2
560 600
Dimensions in mm without commitment. Sense of rotation: clockwise, as seen from the driving side.
Foot dimensions
c
35
m1
m2
n1
n2
Extension dimenfor sion screws
n3
850 720 800 700 400
q
50
s
M30
x
250
765
Shaft end acc. to DIN 748
d 60 75 60 75
l
105
t
u
Others
y
z
64 18 57 148 79.5 20 122 64
18
79.5 20
118
57 122
Installation dimensions are available in ALLWEILER drawing archive ALL2CAD. Allocation of the bearing housing sizes to the speeds -1
Pump size
Speed [ min ] 950
1180
1450
1780
Bearing housing size 300-315/01 300-400/01
585
700
up to the max. power 200 kW; above 200 kW bearing housing size 700 has to be used
VM 538 GB/05.06 – Ident-No. 795 213
15
Series NT
Subject for technical alterations.
ALLWEILER AG Postfach 1140 78301 Radolfzell Allweilerstr. 1 78315 Radolfzell Germany Tel. +49 (0)7732 86-0 Fax. + 49 (0)7732 86-436 E-mail:
[email protected] Internet: http://www.allweiler.com VM 538 GB/05.06 – Ident-No. 795 213